CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT

WATER INJECTION FACILITIES - CUSIANA


TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SUMMARY REVISION : 0  PG. 1

TALLERES DE M E C A N I C A I. K L E I N & C I A. L T D A .

CAL C U LAT I O N SHEETS

G E N E R A L R E V I E W No. 0

DAT E : 28 OCT 96

PRODUCTION ORDER: M - 6182 - 01

CUSTOMER : FOSTER WHEELER ANDINA S.A.


CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA

PROYECT : INJECTION WATER STORAGE


74'6" Inside Diameter x 40'0" High

TAG : TK - 60001

CAPACITY : 25200 BBL

TYPE : CONICAL ROOF TYPE


CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SUMMARY REVISION 0  PG. 2

TALLE R E S DE M E C A N I C A I. K L E I N & C I A. L T D A .

CAL C U LAT I O N SHEETS

SUMMARY I N D E X

DOCUMET TITLE S.D.R.L. No. REV NO - S.D.R.L. No.

SUMMARY 6182 400


SHELL THICKNESS CALCULATION 6182 401 0
TOP ANGLE ANALYSIS 6182 402 0
ANNULAR RING CALCULATION 6182 403 0
BOTTOM THICKNESS CALCULATIO 6182 404 0
SEISMIC DESIGN 6182 405 0
ROOF THICKNESS CALCULATION 6182 406 0

ADMISSIBLE NOZZLE LOADS 6182 407


CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SUMMARY REVISION 0  PG. 3

SUMMARY

1.DESIGN DATA

BRITISH SISTEM METRIC SISTEM


D = Inside Diameter 74.500 Ft 22.71 M
H = Height At Top Angle 40.000 Ft 12.19 M
H1 = Liquid Height 37.500 Ft 11.43 M
C1 = Roof Corrosion allowance 37.500 in. 952.50 mm 1/16"
C2 = Shell Corrosion allowance 0.063 in. 1.59 mm 1/16"
C3 = Bottom Corrosion allowance 0.063 in. 1.59 mm 1/16"
G = Specific Gravity 1.000
T = Design Temperature 100 ºF KLEIN RESTRICTION - COSTUMER SPECIFICATION: 200
V = Wind velocity 70.000 mph 112.63 Km/H
Place/Town/Country Cusiana - Casanare - Colombia
Seismic Zone - A.P.I. 4 Costumer Data
Z = Seimic Zone factor Horizontal Acceleration 0.46 Table E-2 Costumer Data
I = Service Factor 1 Costumer Data
S = Soil Type S3 Costumer No Data
Site factor see table E-3 1.20 Costumer Data
K Factor see fig E-4 0.600
Portion Weight 40 % CONICAL ROOF TYPE
C1 = Lateral Heartquake Force Factor - E.3.3 0.60 D/H
W1 / WT see fig E-2 0.55 W2 / WT see fig E-2
X1 / H see fig E-3 0.38 X2 / H see fig E-3

Shell material A-36


plates dimensions Width : 6 Ft 1829 mm
Length: 20 Ft 6096 mm
Bottom material A-36
plates dimensions Width : 6 Ft 1829 mm
Length: 20 Ft 6096 mm
Annular ring material A-36
plates dimensions Width : 6 Ft 1829 mm
Length: 20 Ft 6096 mm
Wind Girder material N.A
plate thickness 0.000 in. 0.00 mm
Width Wind Girder : 0.00 in
plates dimensions Width : 0 Ft 0 mm
Length: 0 Ft 0 mm
Clean Out material N.A.
plates dimensions Width : 6 Ft 1829 mm
Length: 20 Ft 6096 mm
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
Dimensi 0 " x 0 " Quantity 1 %lam
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SUMMARY REVISION 0  PG. 4

SUMMARY

2.CALCULATIONS SUMMARY: ( ONLY FOR SHELL PLATES)

1-FOOT METOD QTY PLATES


SHELL : MATERIAL THICKNESS NET

1st COURSE A-36 PLATE 3/8" Err:520 6 FT x 20


2nd COURSE A-36 PLATE 3/8" 12.0 6 FT x 20
3rd COURSE A-36 PLATE 5/16" 12.0 6 FT x 20
4rd COURSE A-36 PLATE 1/4" 12.0 6 FT x 20
5rd COURSE A-36 PLATE 1/4" 12.0 6 FT x 20
6rd COURSE A-36 PLATE 1/4" 12.0 6 FT x 20
7rd COURSE A-36 PLATE 1/4" 12.0 4 FT x 20

TOP ANGLE A-36 3 x 3 x 3/8 15 pieces /6 m each 863

WIND GIRDER
WIND GIRDER IS NOT REQUIRED
Minimum Wind Girder Width: 0 "
Nominal thickness
N.A PLATE 0.00 8 0 FT x 0

ANNULAR RING ANNULAR RING NO IS REQUIRED

Nominal thickness
A-36 PLATE 0.313 13 6 FT x 20
Minimum radial width : 30.00 "

BOTTOM

Nominal thickness
A-36 PLATE 0.313 35 6 FT x 20

SEISMIC CALC

M = Overturning Moment = ### lb - Ft


THE TANK NOT IS STABLE TO OVERTURNING - ANCHORED IS REQUIRED
O.K. THE TANK IS ESTRUCTURALLY ESTABLE
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
CALCULATION SHELL THICKNESS REVISION 0  PG. 1/1

CALCULATION SHELL THICKNESS

1-FOOT METHOD - A.P.I. 3.6.3.

DESIGN DATA

D = Inside Diameter 74.500 Ft Td = Design shell thickness


H = Height At Top Angle 40.000 Ft Tt = Hydrostatic test shell thickness
H1 = Liquid Height 37.500
C2 = Shell Corrosion allowance 0.063 in
G = Specific Gravity 1.000 Temperature : 100 §F
Sd = Allowable Stress Design 23200 psi A-36 MDMT 32 §F
St = Allowable Stress Hydrotest 24900 psi A-36 MDMT 32 §F

1. CALCULATION

H MATERIAL CALCULATED USED QTYWEIGHT


Ft THICKNESS THICKNESS PLATES NET
in in NET Lb
1st COURSE
Td={2.6*D*(H-1 37.5 A-36 0.367 0.375 PLATE 3/8" 11.7 21516
Tt = {2.6*D*(H-1)/St} 0.284 0.394 PLATE 10 mm 0
0
2nd COURSE 0
Td={2.6*D*(H-1 31.5 A-36 0.317 0.375 PLATE 3/8" 11.7 21516
Tt = {2.6*D*(H-1)/St} 0.237 0.354 PLATE 9 mm 0
0
3rd COURSE 0
Td={2.6*D*(H-1 25.5 A-36 0.267 0.313 PLATE 5/16" 11.7 17929
Tt = {2.6*D*(H-1)/St} 0.191 0.314 PLATE 8 mm 0
0
4rd COURSE 0
Td={2.6*D*(H-1 19.5 A-36 0.217 0.250 PLATE 1/4" 11.7 14342
Tt = {2.6*D*(H-1)/St} 0.144 0.236 PLATE 6 mm 0
0
5rd COURSE 0
Td={2.6*D*(H-1 13.5 A-36 0.167 0.250 PLATE 1/4" 11.7 14342
Tt = {2.6*D*(H-1)/St} 0.097 0.236 PLATE 6 mm 0
0
6rd COURSE 0
Td={2.6*D*(H-1 7.5 A-36 0.117 0.250 PLATE 1/4" 11.7 14342
Tt = {2.6*D*(H-1)/St} 0.051 0.236 PLATE 6 mm 0
0
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
7rd COURSE 0
Td={2.6*D*(H-1 1.5 A-36 0.067 0.250 PLATE 1/4" 11.7 14342
Tt = {2.6*D*(H-1)/St} 0.004 0.236 PLATE 6 mm 0
0
SUMMARY
1st COURSE A-36 PLATE 3/8" Err:520 6 FT x 20
2nd COURSE A-36 PLATE 3/8" 12 6 FT x 20
3rd COURSE A-36 PLATE 5/16" 12 6 FT x 20
4rd COURSE A-36 PLATE 1/4" 12 6 FT x 20
5rd COURSE A-36 PLATE 1/4" 12 6 FT x 20
6rd COURSE A-36 PLATE 1/4" 12 6 FT x 20
7rd COURSE A-36 PLATE 1/4" 12 4 FT x 20
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
TOP ANGLE ANALYSIS REVISION 0  PG. 1/2

TOP ANGLE ANALYSIS

A.P.I. 3.1.5.9.

1. TOP ANGLE - A.P.I. 3.1.5.9.

D = Inside Diameter 74.5 Ft


Top Angle Dimension: 3 x 3 x 3/8 Leng developmet: 2835 in
15 pieces /6 m each

2. TOP ANGLE MODULUS VERIFICATION - TABLE 3-22

SECTION:
See table 3.22. and Fig. 3.18. detail a

FIG

d= 3.000
tw = 0.375
t= 0.250

DESIGN DATA
Modulus Required: 10.88 in^3
Wing Angle : 3.00 in
Thickness Angle : 0.38 in
Shell Thickness last course: 0.25 in

TOP ANGLE PROPERTIES:


NOTE: Roller Shapes Data By AISC.
Wing angle Length d1 3.000 in 76.2 mm
Wing angle Length d2 3.000 in 76.2 mm
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
Tickness Wing Angle tw1 0.375 in 9.525 mm
Tickness Wing Angle tw2 0.250 in 6.35 mm
WEIGHT
Element 1 3.82 lb/ft 5.70 Kg/m
Element 2 2.55 lb/ft 3.80 Kg/m
T O TAL WEIGHT 6.37 lb/ft 9.50 Kg/m
CALCULATION IN AXIS X-X CALCULATION IN AXES Y-Y
ELEMENT 1 ( horizontal wing ) ELEMENT 1 ( horizontal wing )
Area 1.125 in2 Area
Y ( average ) 0.188 in X ( average )
A*Y 0.211 in3 A*X
A*Y2 0.040 in4 A*X2
Io 0.013 in4 Io
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
TOP ANGLE ANALYSIS REVISION 0  PG. 2/2

ELEMENT 2 ( vertical wing ) ELEMENT 2 ( vertical wing )


Area 0.656 in2 Area
Y ( average ) 1.688 in X ( average )
A*Y 1.107 in3 A*X
A*Y2 1.869 in4 A*X2
Io 0.377 in4 Io

Total Area At 1.781 in2 Total Area


Distance at axis X-X Y 0.740 in Distance at axis Y-Y
Summatory de A*Y 1.318 in3 Summatory A*X
Summatory A*Y2 1.908 in4 Summatory A*X2
Summatory Io 0.390 in4 Summatory Io

Inertia related to axis 1-1 I-1 2.298 in4 Inertia related to axis 1-1
Inertia related to axis X-X Ix 1.323 in4 Inertia related to axis Y-Y
Section Modulus in X Sx 0.585 in3 Section Modulus in Y
Turning Radius in X rx 0.862 in Turning Radius in Y

A1 = Angle Area = 1.781 in^2


A2 = 0.250 x 1.38 = 0.344 in^2

y = Centroid Angle = 0.740 in. them y1=


y = Centroid Angle - e/2 them y2=

I1 = Angle's Inertia = 1.323 in4


I2 = 0.0833 x 1.375 x 0.02 = 0.002 in4

CENTROIDS AND INERTIA:


ELEMENT AREA Y AxY A x Y^2 Io
1 1.78 2.26 4.03 9.10 1.32
2 0.34 2.88 0.99 2.84 0.00

SUMMAT 2.13 5.01 11.94 1.32

Y= 2.36 in.
I 1-1= 13.3 in4
Ix = 1.43 in4
SECTION MODULUS:
Z=I/c Z= ### in3 PARTIAL CONTRIBUTION FOR SECTION MODULUS NECESSARY
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
NOTE : WIND GIRDER IS NO REQUIRED BY CONICAL ROOF
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
CALCULATION WIND GIRDER REVISION 0  PG. 1/2

CALCULATION WIND GIRDER


NO REQUIRED
A.P.I. 3.9.6. AND 3.9.7.

DESIGN DATA

D = Inside Diameter 74.5 Ft


H = Height At Top Angle 40 Ft
Thickness last course 0.250 in.
V = Wind velocity 70 mph

1. SECTION MODULUS - A.P.I. 3.9.6.

Minimum section modulus required is:


Z = 0.0001*D^2*H*(V/100)^2 = 10.88 In^3
NOTE: Is necesary to calculate a: WIND GIRDER

2. INTERMEDIATE WIND GIRDER CALCULATION - A.P.I. 3.9.7.

NOTE: THE WIND GIRDER IS USED AS WALKWAY TOO


MAXIMUM VERTICAL DISTANCE
Thickness last course = 0.25 in
H1 = 600t x SQR(100t/D)^3*(100/V)^2 = 59.51 Ft Teorical
H2 = Height Tank - 3.5' = H - 3.5" = 36.50 Ft Real
H1 at H2 => 59.51 > 36.50 Ft WIND GIRDER IS NOT REQUIRED

H1 at H => 59.51 > 40.00 Ft WIND GIRDER IS NOT REQUIRED


NOTE: Top Angle Section Modulus must be verificated
Top Angle Section Modulus must be verificated

3. SECTION MODULUS FOR INTERMEDIATE WIND GIRDER - TABLE 3.22 - FIG 3-18

SECTION:
See table 3.22. and Fig. 3.18. detail e

FIG
tn = 0.000
t= 0.250

DESIGN DATA
Required Modulus : 10.88 in^3
Minimum Width Wind Girder : 0.00 in
Tickness Plate : 0.00 in
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
Shell Tickness last course: 0.25 in
Wind Velocity : 70.00 mph
Others dimensions by A.P.I. and Klein's standart
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
CALCULATION WIND GIRDER REVISION 0  PG. 2/2

PROPERTIES:
A1= 0.0000 x 6.00 = 0.00 in2 NO REQUIRED
A2= 0.0000 x 2.50 = 0.00 in2
A3= 0.0000 x 0.00 = 0.00 in2
A4= 0.2500 x 8.00 = 2.00 in2

Y1= 0.00 in.


Y2= 1.25 in.
Y3= 0.00 in.
Y4= 0.13 in.

I1= 0.0833 x 6.00 x 0.00 = 0.00 in4


I2= 0.0833 x 0 x 15.63 = 0.00 in4
I3= 0.0833 x 0 x 0 = 0.00 in4
I4= 0.0833 x 8 x 0.02 = 0.01 in4

CENTROIDS AND INERTIA:


ELEMENT A Y AxY A x Y^2 Io
1 0.00 0.00 0.00 0.00 0.00
2 0.00 1.25 0.00 0.00 0.00
3 0.00 0.00 0.00 0.00 0.00
4 2.00 0.13 0.25 0.03 0.01

SUMMAT 2.00 0.25 0.03 0.01

y= 0.125 in.
I1-1 = 0.042 in4
Ix = 0.010 in4

SECTION MODULUS: Z wind girder= 0.083 in3


Z=I/c Z top angle = 1.609 in3
Z required = 10.878 in3 SECCION MODULUS IS NOT O. K.

4. PLATE REQUIRED TO MADE THE WIND GIRDER

Plate dimensions : 0 FT x 0 FT x 0 in
Sectors per plate : 4 sectors
Sectors dimensions: 4 FT x 12.5 FT
Shell thickness last course: 0.25 inch
Outside Shell Diameter in last course: 74.542 FT 22720 mm
Sectors 27 Arco: 13.3 grados
Sector length (chord): 104.6 inch O.K.
sector width : 11.0 inch O.K.
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
Circular laders : 1
required plates : 8 plates included one aditional plate for spiral lader each
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
CALCULATION ANNULAR RING REVISION 0  PG. 1/2

CALCULATION ANNULAR RING

A.P.I. 3.5. AND APP E.4.

DESIGN DATA

Annular ring material A-36


Bottom material A-36
D = Inside Diameter 75 ft
H1 = Height - Liquid Level 38 ft
C = Corrosion Allowance 0.063 in
G = Specific Gravity 1.000
t = Design Thickness - 1th course 0.367 in without adjustment to comercial thickness
t1 = Thickness Shell - 1th course 0.375 in
Sd = Design Stress Admissible 23200 psi A-36
St = Hidrotest Stress Admissible 24900 psi A-36

1. ANNULAR RING THICKNESS CALCULATION - A.P.I. 3.5.


-------------------- ------------------------------- ------------ -------------
A.P.I. Table 3.1.
Nominal Tickness 1st course Hydrostatic test Stress
<= <= <= <=
27000 30000 33000 36000
psi. psi. psi. psi.
t <= 0.75 0.250 0.250 0.281 ###

Hydrostatic Stress 1st course


2.6*D*(H-1) / t-C 23200 <= 27000

Minimum annular ring thickness Err:520 in A.P.I. Table 3-1


C = Corrosion Allowance 0.063 in

tb = Minimum Thickness Annular ring Err:520 in 1st selection: 0.313 in

2. ANNULAR RING THICKNESS RELATED TO SEISMIC CALCULATIONS - A.P.I. - E.4.2


-------------------- ------------------------------- ------------ ------------- ------------------- --------------- -----------------------
1/4" Compared with t, use the greater 0.25 in < 0.367 in /use as a reference
tb < reference thickness 0.31 in < 0.367 in

USE : 0.313 in O.K. RIGHT SELECCION

2. ANNULAR RING BY A.P.I. - 3.5.1.


CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
-----------------------------------------------------------------------------------------------------------------------------------------------
1st SHELL COURSE AND BOTTOM ARE IN GROUP I MATERIAL : NO IS REQUIRED ANNULAR RING
BOTTOM AND ANNULAR RING ARE IDENTICAL THICKNESS.

ANNULAR RING NO IS REQUIRED


CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
CALCULATION ANNULAR RING REVISION 0  PG. 2/2

3. MINIMUM RADIAL WIDTH ANNULAR RING - A.P.I. 3.5.


-------------------- ------------------------------- ------------ -------------
24+(t1)+2.5+2 28.875 in

RADIAL WIDTH CALCULATED


390*tb/SQRT (H*G) Err:520 in Err:520 Err:520

4. MINIMUM RADIAL WIDTH ANNULAR RING RELATED TO SEISMIC CALCULATIONS - A.P.I. APP E.4.2.
-------------------- ------------------------------- ------------ ------------- ------------------- --------------- ----------------------- -----------------
Annular Ring Internal projection Ip= 0.027WL/GH 24.783 in
Annular ring width Ip +t1+ 2" 27.158 in

COMPARED THE WIDTH CALCULATED TO SEISMIC WIDTH Err:520 Err:520 27.158

MINIMUM WIDTH TO USE Err:520

RADIAL WIDTH TO USE 30.0 in Err:520

5. PLATE REQUIRED TO MADE THE ANNULAR RING

Plate dimensions : 6 FT x 20 FT x 0.3125 Inch


Sectors per plate : 2 sectors
Sectors dimensions: 3 FT x 25 FT
Outside proyection to shell : 3 inch (2" by A.P.I.3.5.2.)
1st course thickness : 0.375 inch
Outside diameter Annular Ring: 75.0625 FT 22879 mm
Sectors 26.00 Arc: ### grados
Sector length (chord): 108.6 inch O.K.
sector width : 33.1 inch O.K.
required plates : 13 plates Discount Clean out basements plate
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
BOTTOM THICKNESS ANNALISIS REVISION 0  PG. 1/1

BOTTOM THICKNESS ANALYSIS

A.P.I. 3.4. AND APP E.4.

1. BOTTOM - A.P.I. SEC. 3.4

3.4.1. All bottom plates shall have a minimum nominal thickness of 1/4",
exclusive of any corrosion allowance specified.
Then:

Minimum nominal thickness 0.250 in


Corrosion allowance 0.063 in

NOMINAL BOTTOM THICKNESS 0.313 in USE : 0.3125 in.


USE : 0.3150 in. 8  MM

2. BOTTOM THICKNESS RELATED TO SEISMIC CALCULATIONS - A.P.I. - APP E.4.2.

N.A. - APPLIED ONLY TO ANNULAR RING

3. BOTTOM PLATES REQUIRED


-------------------- -------------------------------
Bottom cuts diameter : 845.75 in 21482 mm
Plate dimensions : 6 FT x 20 FT x 0.3125 Inch
Factor for overlaps and extreme plates: 6 % (2% Recomended)
Plates quantity to use: 35 Plates
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SEISMIC DESIGN REVISION 0  PG. 1/4

SEISMIC DESIGN

A.P.I. APP E

DESIGN DATA

D = Inside Diameter 74.5 Ft


H = Ht = Height At Top Angle 40.0 Ft
H1 = Liquid Height 37.5 Ft
G = Specific Gravity 1.000
Ws = Total Shell Weight 112670 lb
Shell Courses 110670 lb
Nozzles and accesories 1000 lb
Ladder 1000 lb
Xs = Center gravity Height 18.750 Ft ASSUMED : Xs = H1 / 2.2
Wr = Total Roof Weight 45295 lb
Tank Roof 43895 lb 1/4" THK
Nozzles and accesories 1000 lb
Others 200 lb
Estructure at roof 200 lb
WT = Total Weight Liquid content 10193887 lb

Place/Town/Country Cusiana - Casanare - Colombia


Seismic Zone - A.P.I. Costumer Data 4
Z = Seimic Zone factor Horizontal Acceleration 0.46 Table E-2
I = Service Factor Costumer Data 1
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SEISMIC DESIGN REVISION 0  PG. 2/4

1. DESIGN LOADING - OVERTURNING MOMENT - A.P.I. APP E.3.1.


-------------------- ------------------------------- ------------ ------------- -------------------
W1 = Weight efective mass of the tank contents that move in unison with tank shell - E.3.2.1

W2 = Weight efective mass of the tank contents that move in the first sloshing - E.3.2.1

D/H 1.99

W1 / WT see fig E-2 0.55


W2 / WT see fig E-2 0.43

W1= WT*(W1/WT) 5606638 lb


W2= WT*(W2/WT) 4383371 lb

X1 = Height centroid of lateral seismic force for W1 applied - E.3.2.2

X2 = height centriod of lateral seismic force for W2 applied - E.3.2.2

X1/H see fig E-3 0.38


X2/H see fig E-3 0.6

X1= H*(X1/H) 14.25 pies


X2= H*(X2/H) 22.50 pies

S = Soil Type Costumer Data S3


Site factor see table E-3 1.2
K Factor see fig E-4 0.60

T = Natural Per T=k*D^1/2 5.18 sec

C2 = Lateral Heartquake Force Factor - E.3.3 0.060 T > 4.5


If T <= 4.5 them C2= 0.30 S/T = 0.070
If T > 4.5 them C2= 1.35 S/T^2 = 0.060
C1 = Lateral Heartquake Force Factor - E.3.3 0.6

M = Overturming Moment
M = Z*I*((C1*Ws*Xs)+(C1*Wr*Ht)+(C1*W1*X1)+(C2*W2*X2))= M = 25874373
CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SEISMIC DESIGN REVISION 0  PG. 3/4

2. RESISTANCE TO OVERTURNING - A.P.I. E.4.1.


-------------------- ------------------------------- ------------
tb = Annular ring thickness or Bottom Tickness 0.313 in
Annular Ring Material or Bottom Material A-36
Fby= Minimum Yield Stress of the annular ring or Bottom 36000 psi
t = 1st Course Tickness 0.367 in
Fty= Minimum Yield Stress of the 1st Course 36000 psi
G = Specific Gravity 1.000
H1 = Liquid Height 37.500 Ft

Wl = Maximum weight tank contents that may be used to resist


Wl maximum = 1.25*G*Ht*D 3492 lb / ft of shell circunference
Wl calculated = 7.9*tb*(Fby*G*H)^1/2 2868 lb / ft of shell circunference

Wl max > Wl calc Use: Wl calc 2868 lb / ft of shell circunference

Wt = Weight Shell Tank and Portion Weight Roof - A.P.I. APP E 559 lb / ft of shell circunference
Portion Weight 40 % CONICAL ROOF TYPE

M = Overturning Moment 25874373 lb - Ft

W lift = Lift Load


W lift = M / Tank Area 5936 lb / ft

Resistance to overturning:
Wt + Wl > W lift 3427 < 5936 lb / ft

THE TANK NOT IS STABLE TO OVERTURNING - ANCHORED IS REQUIRED


CUSIANA/ CUPIAGUA FULL FIELD DEVELOPMENT PROJECT
WATER INJECTION FACILITIES - CUSIANA
TALLERES DE MECANICA I. KLEIN & CIA. LTDA.-INGENIERIA
FOSTER WHEELER ANDINA S.A. INJECTION WATER STORAGE
CALCULATION SHEET FOR API 650 STORAGE TANK TAG       TK - 60001
CONICAL ROOF TYPE CAPACITY: 25200 BBL
SEISMIC DESIGN REVISION 0  PG. 4/4

3. ANNULAR RING DIMENSIONS RELATED TO SEISMIC CALCULATIONS - A.P.I. - APP E.4.2.

Bottom Tickness tf 0.3125 in


1st course Shell t ### in
Annular Ring Tickness tb 0.3125 in
Annular Ring width wb 30 in See Annular rig Calculation

MINIMUM RADIAL WIDTH ANNULAR RING


Internal projection Ip= wb -2" -t 27.63 in
Minimum Internal projection by sismo Ip= 0.027WL/GH 24.78 in O.K.

BOTTOM THICKNESS N.A. - APPLIED ONLY TO ANNULAR RING

ANNULAR RING THICKNESS


1/4" Compared with t, use the greater 0.25 in < 0.367 in /use as a reference 0.37
tb < reference thickness 0.31 in < 0.367 in O.K.

4. SHELL COMPRESSION - A.P.I. APP E.5

ANCHORED TANKS - A.P.I. 620 - APP E.5.2.

b = Wt + (1.273 *M) / D^2 5934.62

Fa = Maximum allowable longitudinal compresive stress

If : G*H*D^2 /(t-c)^2 > 10^6 1st case


Or : G*H*D^2 /(t-c)^2 < 10^6 2nd case 2241170 > 10^6 applied 1st case

1st case: then Fa = 10^6*(t-c)/D 4091 psi


However Fa < 0.5 Fty 0.5Fty= 18000 Then Fa < 0.5 Fty O.K.

2nd alternative stability condition:


If : b /12(t-c) < Fa 1622.85 < Fa condition cumplied

O.K. THE TANK IS ESTRUCTURALLY ESTABLE


COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.: 6182 400

A. L T D A .
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.: 6182 400

N & C I A. L T D A .

REV

0
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.: 6182 400

N - COSTUMER SPECIFICATION: 200 ºF

ONICAL ROOF TYPE


1.987
0.43
0.60
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
0
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.: 6182 400

FT USE 10 MM
FT USE 9 MM
FT USE 8 MM
FT USE 6 MM
FT USE 6 MM
FT USE 6 MM
FT USE 6 MM

FT

FT

FT

FT
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.: 6182 401

QTY WEIGHT
PLATES GROSS
ADJUST Lb

Err:520 Err:520 11.7


Err:520 Err:520 Clean Out
0 adjust
0
12.0 22054 11
0
0
0
12.0 18378 11
0
0
0
12.0 14702 11
0
0
0
12.0 14702 11
0
0
0
12.0 14702 11
0
0
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
0
0.0 0 11
0
0

FT USE 10 MM
FT USE 9 MM
FT USE 8 MM
FT USE 6 MM
FT USE 6 MM
FT USE 6 MM
FT USE 6 MM
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 402

pieces /6 m each 84.0 M

in
in
in
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A

1.13 in2
1.50 in
1.69 in3
2.53 in4
0.84 in4
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 402

0.66 in2
0.13 in
0.08 in3
0.01 in4
0.00 in4

At 1.781 in2
X 0.993 in
1.770 in3
2.542 in4
0.847 in4

I-1 3.389 in4


Iy 1.631 in4
Sy 0.813 in3
ry 0.957 in

2.26 in.
2.88 in.

SECTION MODULUS NECESSARY


COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
QUIRED BY CONICAL ROOF
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.

in
in
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No.

NO REQUIRED

ECCION MODULUS IS NOT O. K.


COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 403

5/16"

0.37 in

K. RIGHT SELECCION
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A

IRED
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 403
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 404

O.K.
O.K.
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 405
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 405

lb - Ft
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 405
COSTUMER DOC No.:

S.O. 6128-R-001
DATE        :

28 OCT 96
BY            :

P.D.P.A
No. 6182 405

in