Contact-Cooled Rotary Screw Air Compressor


RS30IE, RS37IE

Product Maintenance Information

Save These Instructions


EN

Contents
ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cleaning Motor Cowl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
PERSONNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Cleaning / Checking Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cleaning / Installing Package Pre-Filter (cooling suction). . . . . . . . . . . . 8
AIR COMPRESSOR MAINTENANCE. . . . . . . . . . . . . . . . . . . . . 4
Cleaning / Instaling package Pre-filter (airend suction). . . . . . . . . . . . . . .8
Maintenance Prompts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Checking / Cleaning No Loss Drain Trap (where fitted) . . . . . . . . . . . . . . . .8
Maintenance Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Monitoring Fluid and Performing Shock Pulse Bearing Analysis . . . . . . .8
Routine Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Checking Coolant Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 INTEGRATED DRYER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . .12
Adding Coolant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Maintenance Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Draining Coolant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Cleaning Condensate Drains (Timed Drains Only) . . . . . . . . . . . . . . . . . . .12
Sampling Coolant for Analysis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Testing Condensate Drains (No-Loss Drains Only) . . . . . . . . . . . . . . . . . . .12
Changing Coolant Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Troubleshooting Condensate Drains (Electronic Drains Only) . . . . . . . . 12
Checking Separator Element. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Disassembling the Integrated Dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Changing Separator Element. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Decommissioning the Integrated Dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Inspecting Separator Tank / Pressure System . . . . . . . . . . . . . . . . . . . 7

Cleaning / Checking Scavenge Screen . . . . . . . . . . . . . . . . . . . . . . . . . .7

Replacing Coolant Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Checking Minimum Pressure Check Valve (MPCV) . . . . . . . . . . . . . . .7

Changing Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Regreasing Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Cleaning Air Cooled Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Removing / Installing Air Cooled Cooler


(combination cooler for R30-37) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Removing / Installing Air Cooled Cooler


(Sequential cooler for R37e-160) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Cleaning Water Cooled Cooler


(for both Clean & Harsh Water Options) . . . . . . . . . . . . . . . . . . . . . . . . 8

Checking High Airend Temperature Sensor . . . . . . . . . . . . . . . . . . . . . 8

EN- 80448863 Rev C


EN

ABOUT THIS MANUAL


The purpose of this manual is to provide maintenance and troubleshooting guidelines for the compressor.
For supporting documentation refer to Table 1.
Table 1: Product Manuals
Part/Document Number by Region
Publication Product
Americas EMEA * Asia Pacific
Product Safety Information Manual All 80446313 80446156 80446321
Product Information Manual RS 30-37IE 80448830 80448848 80448855
Product Maintenance Manual RS 30-37IE 80448863 80448871 80448889
Product Parts Information Manual RS 30-37IE 80448897
* Europe, Middle East and Africa
Product specification sheets and reference drawings are also available.

PERSONNEL
Proper use, inspections and maintenance increases the life and usefulness of the compressor. It is extremely important that anyone involved with maintaining
the compressor be familiar with the servicing procedures of these compressors and be physically capable of conducting the procedures. These personnel shall
have skills that include:
1. Proper and safe use and application of mechanics common hand tools as well as special Ingersoll Rand or recommended tools.
2. Safety procedures, precautions and work habits established by accepted industry standards.
Some maintenance procedures are technical in nature and require specialized tools, equipment, training and experience to accomplish correctly. In such
situations, only allow Ingersoll Rand trained technicians to perform maintenance on this compressor. Service or inspections beyond the procedures given in
this manual shall not be attempted by operating personnel.
For additional information contact the Ingersoll Rand factory or the nearest service provider.

SAFETY
Before undertaking any work on the compressor, ensure that the electrical supply has been isolated, and remote start/stop function is not enabled, locked
off, tagged and the compressor has been relieved of all pressure. Ensure the compressor is electrically isolated for at least 15 minutes before commencing any
maintenance work. See the Product Safety Information manual for additional information.
Ingersoll Rand cannot know of or provide all the procedures by which repairs may be conducted and the hazards and/or results of each method. If
maintenance procedures not specifically recommended by the manufacturer are conducted, ensure that safety is not endangered by the actions taken.
If you are unsure of a maintenance procedure or step, place the compressor in a safe condition before consulting technical assistance.
The use of other than genuine Ingersoll Rand replacement parts may result in safety hazards, decreased performance and increased maintenance and may
invalidate all warranties.
For additional information contact the Ingersoll Rand factory or the nearest service provider.

80448863 Rev C EN-


EN

AIR COMPRESSOR MAINTENANCE


 Maintenance Prompts  Maintenance Chart
The service warning and flashing LED will appear at intervals dependent Maintenance should be performed per the recommendations below in the
on the service level selected. Refer to the Product Information manual for following priority: (1) Perform maintenance when indicated by the controller;
information about service level settings. (2) Perform maintenance through either hourly intervals or scheduled
maintenance intervals, or (3) Annually.

Table 2: Maintenance Chart (RS30-37ie)


Period Action Maintenance Item
Replace Air filter element
When indicated by
Replace Coolant filter element
controller
Replace Separator element
Check Connections and hoses for leaks
Check Coolant level
Daily Check Condensate drain operation
Check Controller for service indicators
Check Package pre-filter for blockage
Monthly Inspect Air-cooled cooling system for blockage
Every 1000 hours Analysis Food-grade Lubricant (Ultra FG)
Inspect Air filter element
Every 2000 hours or Inspect Coolant filter element
3 months Analysis Shock pulse bearing
Analysis Premium Coolant (Ultra/Ultra EL)
Inspect Scavenge screen for blockage
Replace Air filter element
Replace Coolant filter element
Every 4000 hours or Replace Package pre-filter elements
6 months Clean Cooling system
Calibrate Pressure transducers
Grease All motors (as required)
Replace Dryer filter (if applicable)
Replace Food-grade Lubricant (Ultra FG)
Replace Separator element (if using Food-grade Lubricant)
Every 6000 hours
Inspect Air filter element
Inspect Coolant filter element
Replace Separator element
Replace No-loss condensate drain service module
Every 8000 hours or Replace Premium Coolant (Ultra) [8000 hours or every 2 years]
annually Service Minimum pressure check valve (MPCV) service kit
Clean Drains with all their components (TIMED DRAINS ONLY)
Service Lubricate inlet valve cylinder (modulation packages only)
Service Inlet valve service kit
Replace Rubber hoses
16000 hours
Replace Contact tips
Replace Extended-life Premium Coolant (Ultra EL) [16000 hours or every 3 years]
40000 hours Replace Stainless Steel/PTFE hoses

NOTICE

Inspect and replace coolant filter elements and separator elements more frequently in dirty operating environments.

NOTICE

Read the motor data plate(s) or call the motor manufacturer(s) to determine specific greasing requirements. For motors that require greasing,
grease them more frequently in harsh environments or higher ambient conditions.

EN- 80448863 Rev C


EN

 Routine Maintenance Figure 1: Coolant Drain

This section refers to the various components which require periodic


maintenance and replacement.
Refer to safety information and maintenance procedures prior to carrying out
any of the maintenance in the following sections.

 Checking Coolant Level


A coolant level sight glass is located on the side of the separator tank. While
the compressor is running under load, coolant should always be visible in 1 2
the sight glass. The normal position is half way. The compressor should be
running for at least 40 seconds for this check.
Stop the compressor, ensure the sump pressure is 0 psig and ensure the
coolant is still visible in the sight glass.

 Adding Coolant
Run the compressor for a minimum of 40 seconds. The coolant level should
be visible in the sight glass. If not: 3 4

1. Stop the compressor.


3. Dispose of waste coolant in accordance with local and
2. Isolate the compressor from the external air system. governmental regulations.
3. Press the emergency stop to vent the separator tank and airend.
Compressors can take more than two minutes to fully de-pressurize NOTICE
once stopped.
Shorter coolant change intervals may be necessary if the compressor
4. Slowly unscrew the coolant fill plug to verify all pressure has been is operated in adverse conditions.
released.
5. Add coolant.  Sampling Coolant for Analysis
6. Replace the coolant fill plug and restart the compressor. 1. Bring the compressor up to operating temperature.
7. Recheck the coolant level. 2. Stop the compressor.
8. Repeat the above steps until the coolant level is visible in the sight 3. Isolate the compressor from the external air system.
glass with the compressor both running and stopped.
4. Press the emergency stop to vent the separator tank and airend.
Fixed speed compressors can take more than two minutes to fully
NOTICE
de-pressurize once stopped.
Do not add coolant through the intake of the compressor, as this can 5. Draw a sample from the separator tank port using a pump kit. DO
result in overfilling, saturation of the separator filter element, and NOT draw a sample from the drain port or oil filter.
coolant carry-over downstream.
Use a new hose on the pump for each sample. Failure to do this can give false
readings.
 Draining Coolant
See Figure 2.
It is better to drain the coolant immediately after the compressor has been
operating as the coolant will drain faster and any contaminant will still be in
suspension.
See Figure 1.
1. Place the straight end of the drain hose in a suitable container.
Install the other end of the drain hose in the drain valve. The
coolant flows through the drain hose automatically.
2. After drainage, remove the hose and close the valve.

NOTICE

On air cooled compressors, you may also drain coolant from the
coolant cooler by removing the plug.
You should also drain additional coolant from the airend by removing
the plug in the airend discharge elbow.

80448863 Rev C EN-


EN

Figure 2: Coolant Sampling 7. Install the scavenge tube down into the tank until the tube just
touches the separator element and then raise it 2 mm (0.10 in).
Ensure tube is not raised less than 2 mm (0.10 in) or more than 3
mm (0.125 in). Tighten fittings.

NOTICE

Take extreme caution to not force the scavenge tube into the tank.
This could potentially damage the separator element.

8. Install the piping in the original position.


Figure 3: Recommended Bolt Tightening Cross Pattern

9. Start the compressor and check for leaks.

 Changing Coolant Filter NOTICE


1. Loosen filter with the correct tool.
Do not use any form of sealant on either the separator tank or the
2. Remove the filter from the housing. separator tank cover faces.

3. Place the old filter in a sealed bag and dispose of in a safe way.
4. Clean the mating face of the housing taking care to avoid any
particles entering the machine.
5. Remove the new Ingersoll Rand replacement filter from its
protective package.
6. Apply a small amount of lubricant to the filter seal. Screw the new
filter down until the seal makes contact with the housing, then
hand tighten a further half turn.
7. Start the compressor and check for leaks.

 Checking Separator Element


With the compressor running on load, check the separator differential
pressure via the controller. It will be necessary to change the element if the
differential pressure equals zero or exceeds 1 bar (15 psig).

 Changing Separator Element


1. Remove the fitting that holds the scavenge tube into the tank and
withdraw the tube assembly.
2. Disconnect the piping from the tank cover. Tag the lines if required.
Remove all the bolts securing the cover. Disconnect the piping
from the tank cover. Tag the lines if required. Remove all the bolts
securing the cover. The cover can now be removed to allow access
to inside the tank.
3. Carefully lift the separator element up and out of the tank. Discard
the faulty element.
4. Clean the sealing surface on both the tank and its cover. Check the
tank to be absolutely certain that no foreign objects such as rags or
tools have been allowed to fall into the tank. Lubricate a thin layer
of coolant on the separator seal top and bottom before installing
a replacement element down into the tank after checking the new
element seal for possible damage. Center the element within the
tank ensuring that it is fully seated in the sealing groove. Rotate the
tank cover back into position taking care not to damage the seal,
and locate the cover using two bolts but do not tighten down.
6. Inspect the tank scavenge screen and orifice. Clean if necessary
following the instructions below.

EN- 80448863 Rev C


EN

 Inspecting Separator Tank / Pressure System  Regreasing Motor


Inspect the external surfaces of the airend and separator tank, including all The blower motor contains pre-greased, sealed bearings. They cannot be
fittings, for visible signs of impact damage, excessive corrosion and abrasions. re-greased and do not require re-greasing. For the main motor, consult the
When changing the separator element, inspect the internal components and motor manufacturer to confirm that the motor may be greased and to obtain
surfaces. Any suspect parts shall be replaced before the compressor is put instructions for regreasing.
back into service.
 Cleaning Air Cooled Cooling System
The separator tank should also be tested and inspected in accordance with
any national or local codes that may exist. Air compressor operating temperatures will be higher than normal if the
external passages between the fins of the cooler cores become restricted
 Cleaning / Checking Scavenge Screen with foreign material. Regular cleaning of the cooler surfaces will support
the reliable operation of the air compressor system, improve the life of
The screen/orifice assemblies are similar in appearance to a straight tubing the compressor coolant and improve overall compressor efficiency. When
connector and will be located between two pieces of 6 mm (0.25 in) O.D. performed frequently as determined by site conditions and airborne
scavenge line tubing. contamination, more significant cleaning or replacement may not be
The main body is made from 17 mm hexagon shaped metal and the diameter necessary.
of the orifice and a direction-of-flow arrow is stamped in flat areas of the 1. Stop the compressor.
hexagon.
2. Isolate the compressor from the system.
A removable screen and orifice will require clearing as outlined in the
maintenance chart. 3. Press the emergency stop to vent the separator tank and airend.
Fixed speed compressors can take more than two minutes to fully
To remove the screen/orifice: de-pressurize once stopped.
1. Disconnect the scavenge line tubing from each end. 4. Ensure that the main power disconnect switch is locked off and
2. Hold the center section firmly and use a pair of pliers to gently tagged.
grasp the exit end of the assembly that seals against the scavenge
line tubing. The exit end is the end toward which the arrow is NOTICE
pointing.
For any required lifting of air compressor parts or required tools,
3. Pull the end out of the center section while using care to prevent
always use the proper certified lifting equipment, and employ sound
damage to the screen or sealing surfaces.
working principles.
4. Clean and inspect all parts prior to reinstallation.
5. When the assembly is installed, confirm the direction of flow to 5. Visually check the outside of the cooler cores to determine the
be correct. Observe the small arrow stamped in the center section appropriate cleaning method detailed as follows:
and ensure the direction flow to be from the separator tank to the
airend. a. For loose dirt, dust and other light foreign material, open the access
panel on the cooler plenum. Gently blow compressed air across the
 Checking Minimum Pressure Check Valve (MPCV) cooler surface. Repeat the process until the coolers are sufficiently
clean. Replace the access panels before returning the compressor to
The minimum pressure check valve (MPCV) shall be frequently tested and service.
regularly maintained. Remove it from the compressor for testing. If operating
conditions are particularly severe, the frequency of testing and maintenance b. For thick, packed dirt, coolant or grease, or other heavy material,
shall be increased accordingly. The user shall establish the frequency of the coolers will need to be removed from the compressor for
such tests as it is influenced by such factors as the severity of the operating pressure washing. Ingersoll Rand does NOT support pressure
environment including, but not limited to, cycles. washing coolers when they are installed in the compressor due
to the dangers of spraying water in or around potential electrical
The minimum pressure check valve (MPCV) should be tested and re- power sources. Follow the steps below for cooler removal.
calibrated in accordance with any national or local codes that may exist. If
no code exists, Ingersoll Rand recommends that the valve is recalibrated at  Removing / Installing Air Cooled Cooler
intervals of one year by a licensed contractor or qualified service personnel.
To remove:
 Changing Air Filter
1. Stop the compressor.
1. Check the retaining cap for dirt and debris and wipe clean.
2. Isolate the compressor from the system.
2. Unclip the retaining cap and withdraw the old element.
3. Press the emergency stop to vent the separator tank and airend.
3. Fit the new element and refit the retaining cap. Fixed speed compressors can take more than two minutes to fully
de-pressurize once stopped.
4. Ensure that the main power disconnect switch is locked off and
tagged.
5. Drain the coolant from the coolant cooler.
6. Remove all hoses, pipes, and sensors from the coolers.
7. Remove the external sheet metal panels.
8. Remove cooler mounting connection at the top of the cooler.
(support cooler with appropriate lifting provision prior to removing
mounting connection).
9. Loosen cooler mounting connection at the bottom of the cooler
and ensure free movement of cooler.
10. Remove cooler out from mounting connection.

80448863 Rev C EN-


EN

To install:  Checking / Cleaning No Loss Drain Trap (where fitted)


1. Stop the compressor. It is recommended to check the no loss drain trap daily to ensure that
condensate is draining from the moisture separator system. To check for
2. Isolate the compressor from the system.
correct function:
3. Press the emergency stop to vent the separator tank and airend.
1. Press the test button on the drain and listen for condensate / air
Compressors can take more than two minutes to fully de-pressurize
passing through the drain.
once stopped.
2. If the drain is clogged, replace the no loss drain valve service
4. Ensure that the main power disconnect switch is locked off and
module. The service module consists of the lower portion of the
tagged.
drain trap and is not serviceable.
5. Install cooler mounting connection at the bottom of cooling sheet
Additionally, it is recommended to replace the service module every
metal plenum and keep it loosen.
8000 hours or once per year, whichever comes first.
6. Carefully place the cooler on its proper location and install cooler
mounting connection on the top.  Monitoring Fluid and Performing Shock Pulse Bearing
Analysis
7. Properly tighten all cooler connections.
Ingersoll Rand recommends incorporating predictive maintenance,
8. Re-attach all hoses and pipes and properly torque according part specifically the use of coolant and shock pulse bearing analysis, into all
information manual preventative maintenance programs. Contact Ingersoll Rand for details.
9. Refill the compressor coolant to proper level, following the process
outlined in the “Adding Coolant” procedure.

 Cleaning Motor Cowl


1. Ensure the compressor is electrically isolated for at least 15 minutes
before commencing any maintenance work.
2. Remove the panels from the compressor.
3. Using a clean dry cloth, remove dust from the surface of the motor
cowl and ensure all ventilation slots are free of obstructions.
4. Replace the panels.

 Cleaning / Checking Condensate Drain


1. Ensure the compressor is electrically isolated for at least 15 minutes,
before commencing any maintenance work.
2. Isolate the compressor from the system and fully discharge the
compressed air within the compressor.
3. Remove the tube from the fitting located on the bottom of the
moisture separator.
4. Remove the bowl of the moisture trap, clean and replace.

 Cleaning / Instaling package Pre-filter (cooling suction)


1. Unlatch the two 1/4 turn latches and open the intake panel (panel
is hinged)
2. Remove the nuts and flat washer.
3. Remove the filter grill.
4. Pull out the filter element.
5. Center the new element over the package intake opening. Also
note that the filter is washable with mild detergent.
6. Push the filter over the grill studs so that the studs poke through
the filter media.
7. Install the filter grill.
8. Install the nuts and flat washers.
9. Close the intake panel and latch.

 Cleaning / Instaling package Pre-filter (airend suction)


1. Unlatch one 1/4 turn latch and open intake panel.
2. Remove intake panel from its position.
3. Pull out the filter element.
4. Center the new element over the intake opening.
5. Install panel with filter back to proper position.
6. Close the intake panel and latch.

EN- 80448863 Rev C


EN

TROUBLESHOOTING
This section provides basic troubleshooting information. Determination of specific causes to problems are best identified by thorough inspections performed
by personnel instructed in safety, operation and maintenance of this equipment. The chart below provides a brief guide to common symptoms, probable
causes and remedies.
Table 3: General Faults
SYMPTOM CAUSE REMEDY
Compressor will not start. No power supply to compressor. Check supply is switched on. If so, contact a qualified
electrician.
Controller failure. Check supply to controller. Replace controller.
Starter failure. Isolate supply, lock off and tag. Replace failed component
or contact your local Ingersoll Rand representative.
Controller has tripped the compressor. See tables 3 and 4.
Maximum number of starts per hour exceeded.
Compressor is stopped and will not Controller has tripped the compressor and has not See tables 3 and 4.
restart. been reset.
Emergency stop has been pressed and not released. Identify reason why, repair fault, disengage button and
reset controller.
Emergency stop has been pressed and released but Repair fault and reset controller.
controller has not been reset.
Compressor will not meet pressure Compressor not sized to meet system requirements Contact your local Ingersoll Rand representative.
required by system. or requirements have been changed.
Air loss due to pipe, hose, joint or seal failure. Repair or replace.
Air loss due to blowdown valve stuck open. Repair or replace.
Air loss through pressure relief valve not seating or Repair or replace.
set incorrectly.
Air loss due to moisture separator drain trap stuck Repair or replace.
open.
Controller fault. Repair or replace.
Pressure transducer faulty, incorrectly calibrated or Recalibrate or replace.
EMF interference.
Incorrect controller settings. Check and modify settings.
Inlet grill or ducting is blocked. Check and clean.
Air filter dirty or collapsed. Replace.
Compressor will not meet pressure Inlet valve not opening fully. Repair or replace.
required by system. Separator element dirty or collapsed. Replace.
Pipe / Hoses blocked or collapsed. Clean or replace.
Cooler core blocked. Clean or replace.
Minimum pressure check valve not functioning Repair or replace.
correctly.
Equipment between compressor and customer Review system requirements.
measuring point causing pressure drop / pressure
loss.
Compressor discharge air too hot. High ambient temperature. Review installation and system parameters.
Insufficient cooling air. Check ducting and cooling air path, check direction of
blower rotation.
Dirty, blocked aftercooler (cooling air side). Clean or replace.

80448863 Rev C EN-


EN

Table 3: General Faults (cont.)


SYMPTOM CAUSE REMEDY
Compressor package produces Panels or doors are not closed properly. Rectify fault.
excessive noise.
Air leaks from internal pipework / components. Repair or replace.
Blower or blower motor bearings worn. Repair or replace.
Loose debris impacting on blower during rotation. Remove and rectify any damage.
Blowdown valve stuck open. Repair or replace.
Pressure relief valve not seating correctly. Repair or replace.
Vibration due to motor, airend or blower imbalance. Repair or replace.
Airend requires repair. Contact your local Ingersoll Rand representative.
Discharge air is contaminated with Scavenge pipe is blocked, broken or o-ring is not Clean or replace.
coolant. sealing.
Separator element is punctured, or incorrect, or Replace.
requires changing, or not sealing correctly.
Incorrect coolant has been added. Drain system, check for damage. Clean, refill with correct
coolant.
System has been overfilled with coolant. Check for damage, drain excess.
Discharge air is contaminated with Aftercooler not functioning correctly. Clean or replace.
condensate. Moisture separator drain trap faulty. Repair or replace.
Continuous low ambient operation causing Review system requirements and contact your local
condensate build up. Ingersoll Rand representative.
Compressor package draws too much Compressor operating above rated pressure. Check and modify settings. Review system requirements
current. and contact your local Ingersoll Rand representative.
Separator filter element dirty or blocked. Replace.
Voltage supply is low or unbalanced. Contact your local Ingersoll Rand representative or a
qualified electrician.
Airend is damaged. Contact your local Ingersoll Rand representative.
Coolant loss. Coolant system leak. Repair or replace.
See also ‘discharge air is contaminated with coolant’. See above.
High dewpoint. Refrigeration compressor not supplied power. Check incoming power supply.
Check the dryer protection fuse.
Check auxiliary contact on main motor contactor.
Condensate system malfunction. Check operation of drain valve.
Check operation of condensate check valves.
Condenser dirty. Clean condenser and replace panel filter element.
Ice formation in dryer. Low evaporator pressure. Check hot gas valve setting.
Solenoid condensate valve will not Debris in solenoid valve prevents diaphragm from Remove solenoid valve, disassemble, clean and
close seating. reassemble.
Short in electrical component. Check and replace power cord or timer as needed.

EN-10 80448863 Rev C


EN

Table 4: Controller Faults (indicated on the controller)


FAULT CAUSE REMEDY
Emergency stop. Emergency stop button has been Identify reason why, repair fault, disengage button and reset controller.
pressed.
Blower motor overload. Blower is blocked, damaged or blower Remove blockage, repair or replace damaged components.
motor is faulty.
High airend discharge temperature. Compressor operating above rated Check and modify settings. Review system requirements and contact
pressure. your local Ingersoll Rand representative.
Low coolant level. Check for leaks. See also ‘discharge air is contaminated with coolant’.
Top up coolant.
High ambient temperature. Review installation and system parameters.
Insufficient cooling air. Check ducting and cooling air path.
Dirty, blocked coolant cooler (cooling Clean or replace.
air side).
Blower motor direction of rotation Wire correctly.
incorrect.
Check setpoints. Controller software has been changed. Recalibrate all sensors and check setpoints.
Remote start failure. Remote start button is pressed after Check operation of buttons or operating procedures.
compressor is running or remote start
button remains closed.
Remote stop failure. Remote stop button remains open and Check operation of buttons or operating procedures.
either start button is pressed.
Sensor failure. Sensor is missing or faulty. Install, repair or replace faulty sensor.
Compressor trips indicating a high Insufficient cooling taking place.
compressor temperature.
Controller has tripped the A fault has occurred. Repair fault / reset controller.
compressor.
Invalid calibration. Calibration done with pressure in Depressurize and re calibrate with pressure pipe to sensor
compressor. disconnected. If fault still exists, replace pressure transducer.
Low sump pressure. System leak. Located and repair.
Minimum pressure check valve faulty. Repair with service kit.
Blowdown valve faulty. Repair with service kit.
Loss of control power. Check 110V circuit breaker.
Check wiring.
Check contactor KM1.
Change separator element and/or Separator element dirty or blocked. Change separator element.
high sump pressure. Faulty pressure transducer measurement. Calibrate and validate the wet sump and package discharge
transducers.
Moisture separator condensate drain Ensure condensate drain system is functioning properly, and
trap faulty. condensate is being drained. See Table 3: Troubleshooting Chart.
Change HE filter (integrated dryer Dryer HE filter dirty or blocked. Change HE filter.
models only). Faulty pressure transducer measurement. Calibrate and validate the after cooler discharge and package
discharge transducers.
Moisture separator condensate drain Ensure condensate drain system is functioning properly, and
trap faulty. condensate is being drained. See Table 3: Troubleshooting Chart.
Blockage in dryer. Ensure dryer blockage is not due to freeze up from refrigerant leaks.
Machine stops but no alarm message Loss of outputs of control power. Check controller outputs (110V AC) power supply (fuses/mini circuit
breaker).
Motor current fault(R30-37 only) Loss of control power. Check control power circuit and breaker.
Sump pressure too high. Check separator element pressure drop.
Faulty motor or Airend. Contact your local Ingersoll Rand representative.
CT failure Fault CT, wiring or loss of control power. Check wiring and control power circuit.

80448863 Rev C EN-11


EN

INTEGRATED DRYER MAINTENANCE


 Troubleshooting Condensate Drains (Electronic
WARNING
Drains Only)
Before accessing live electrical parts, disconnect the power supply This section provides basic troubleshooting information. Determination
to the dryer using the disconnect switch or disconnecting the cable of specific causes to problems are best identified by thorough inspections
connections. performed by personnel instructed in safety, operation and maintenance
of this equipment. The chart below provides a brief guide to common
symptoms, probable causes and remedies.
 Maintenance Chart
Table 6: Condensate Drain Troubleshooting Chart
For optimum performance from your dryer, follow the periodic maintenance
schedule described below. TROUBLE CAUSE ACTION
Table 5: Maintenance Chart Solenoid Debris in solenoid valve Remove solenoid valve,
condensate valve prevents diaphragm disassemble, clean and
WEEKLY CONDENSATE DRAINS (TIMED AND NO-LOSS will not close. from seating. reassemble.
DRAINS)
Short in electrical Check and replace power
Verify that the condensate drains are operating component. cord or timer as needed.
correctly by pressing the TEST button.
EVERY 4 MONTHS CONDENSER  Disassembling the Integrated Dryer
Remove any dust from the condenser fins.
NOTICE
EVERY 6 MONTHS AIR FILTER
Replace air filter element. The dryer shall be disassembled, charged or repaired by a refrigerant
specialist.
YEARLY (TIMED DRAINS ONLY)
Refrigerant liquid and lubricating oil inside the refrigeration circuit
Completely disassemble the drains and clean all shall be recovered in compliance with current norms in the country
their components. where the dryer is installed.

 Cleaning Condensate Drains (Timed Drains Only)


NOTICE
Periodically clean the screen inside the valve to keep the drain functioning at
maximum capacity. To do this, perform the following steps: Refrigerant leaks may be identified by tripping of the refrigeration
overload protector.
1. Close the strainer ball valve completely to isolate it from the air
receiver tank. If a leak is detected in the refrigerant circuit, seek technical assistance.
2. Press the TEST button on the timer to vent the pressure remaining If a refrigerant leak occurs, thoroughly air the room before
in the valve. Repeat until all pressure is removed. commencing work.

WARNING NOTICE
High pressure air can cause injury from flying debris. Ensure the In normal temperature and pressure conditions, the R134a refrigerant
strainer ball valve is completely closed and pressure is released from is a colorless, class A1/A1 gas with TVL value of 1000 ppm (ASHRAE
the valve prior to cleaning. classification).

3. Remove the plug from the strainer with a suitable wrench. If you
hear air escaping from the cleaning port, STOP IMMEDIATELY and  Decommissioning the Integrated Dryer
repeat steps 1 and 2. Decommission the dryer and the relevant packaging in compliance with the
4. Remove the stainless steel filter screen and clean it. Remove any rules locally in force.
debris that may be in the strainer body before replacing the filter Pay particular attention to the refrigerant, as it contains part of the
screen. refrigerating compressor lubricating oil.
5. Replace plug and tighten with wrench. Contact a waste disposal and recycling utility.
6. When putting the valve back into service, press the TEST button to Table 7: Integrated Dryer Materials of Construction
confirm proper function.
RECYCLING DISASSEMBLY
 Testing Condensate Drains (No-Loss Drains Only)
Frame and panels Steel / epoxy resin polyester
Press the TEST button to confirm proper function.
Heat exchanger (cooler) Stainless steel / aluminum
Pipes Copper
Insulation Gum synthetic
Compressor Steel / copper / aluminum / oil
Condenser Aluminum
Refrigerant R134a
Valve Steel

EN-12 80448863 Rev C