Power Flow
• Generator local/remote bus voltage
control
• Four solution techniques: Newton-
Raphson, fast de-coupled, hybrid
solution, advanced Gauss Seidel
• Bus types can be defined as
follows: “out of service,” “load,”
“generator,” or “swing bus
• Multiple swing buses/co-generation
units
• Multiple independent islands
Short Circuit
• Unlimited bus simulation (50,000+)
• Calculates short circuit current
using IEEE and IEC standards
• Supports single-phase and 3-
phase networks in the same model
• All types of faults: 3P, L-L, L-L-G,
L-G: solid faults or via an fault
impedance
• Integrated Protective Device
Evaluation (PDE) program
• Short circuit current calculation
inside MCC schedule
Arc Flash
• Unlimited bus simulation (50,000+)
• Program fully integrated with
electrical one-line diagram
• Program Fully integrated with EDSA
Protective Device Coordination
(PDC) program
• Flexible selection of buses, directly
on the one-line diagram or text
driven selection
• Arc Flash exposure based on IEEE
1584 and NFPA 70E
Cable Pulling
• Cable type: single cable, three
cables triangular, three cables
cradled, four cables diamond
• Extensive library: the pulling
compound data, the cable
data/feeder library and the raceway
data. The user may add, modify and
delete entries in the libraries
• Cable data: any size, type, insulation
category, or voltage level can be
entered
Cable Ampacity
• Simulation of soil drying out in the
vicinity of energized cables
• Non-isothermal earth surface
• Cables without metallic sheath but
with copper concentric neutral that
can be single or both ends bonded
and grounded
• Cables on riser poles
• Single phase circuits consisting of
one single core cable with
concentric neutral wires or sheath
serving as the return conductor
Advanced Transients
• Unlimited bus simulation (50,000+)
• Trapezoidal algorithm
• Fast and reliable solution technique
• No limits on number of dynamic
models in study
• Variable integration step
• Extensive machine library
• Fully-integrated with electrical one-
line diagram
• Flexible, fast and accurate
• Multi-speed induction motor
simulation
Voltage Stability
• Unlimited bus simulation (50,000+)
• Fully integrates with Electrical One-
Line Diagram
• Fast, reliable solution technique
• Flexible selection of system load
increases
• User defined groups of generation
for dispatch
• Efficient selection of the monitored
quantities
• Comprehensive Plotting facility for
visualization