Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 39

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Three Story Comparison of Seismic and Wind Based on 2018 IBC / 2016 CBC

INPUT DATA & DESIGN SUMMARY


L= 150 ft, (45.72 m), Building Length (perpendicular, not shown)
B= 50 ft, (15.24 m), Building Width (as shown)
Hr = 4.5 ft, (1.37 m) W3 = 225 kips, (1000.8 kN)
H3 = 8 ft, (2.44 m) (12.8-12)
H2 = 8 ft, (2.44 m) W2 = 337.5 kips, (1501.2 kN)
H1 = 9 ft, (2.74 m) W1 = 375 kips, (1668.0 kN)
Seismic SDS = 0.96 (ASCE 7 Sec 11.4)
SD1 = 0.55 (ASCE 7 Sec 11.4)
S1 = 0.54 (ASCE 7 Sec 11.4)

Wind Exposure (B, C or D) C , (ASCE 7-16/10 26.7.3)


Wind Speed V= 145 mph, (233.35 kph)
(ASCE 7-16/10 26.5.1)

Base Shear (kips) Lateral Force (kips) Overturning (ft-kips)


Vb F1 F2 F3 Mo
Seismic, ASD 98.9 22.6 38.5 37.7 1802.1
(0.11W) ( 0.06 Wx ) ( 0.11 Wx ) ( 0.17 Wx )
Wind, ASD 88.9 25.6 24.1 25.6 5699.3

Determine Seismic Factors


R= 6.5 (ASCE 7 Tab 12.2-1)
I= 1 (2018 IBC Tab 1604.5 & ASCE 7 11.5)
Ct = 0.02 (ASCE 7 Tab 12.8-2)
hn = 25.0 ft
x= 0.75 (ASCE 7 Tab 12.8-2)
T = Ct (hn)x = 0.224 sec, (ASCE 7 Sec 12.8.2.1)

Determine Wind Factors


Kzt = 1 (ASCE 7-16/10 26.8 & Table 26.8-1)
Kd = 0.85 (ASCE 7-16/10 Tab. 26.6-1, for building)
G Cp i = 0.18 or -0.18 (ASCE 7-16/10 Tab. 26.11-1, Enclosed Building)
pmin = 16 psf (ASCE 7-16/10 28.4.4)
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
a= 5.00 ft (ASCE 7-16 Fig 28.3-1)
Kh = 0.96 (ASCE 7-16 26.10-1, pg 268)
qh = 43.83 psf (ASCE 7-16 Eq. 26.10-1 page 268)
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Two Story Comparison of Seismic and Wind Based on 2018 IBC / 2016 CBC

INPUT DATA & DESIGN SUMMARY


L= 150 ft, (45.72 m), Building Length (perpendicular, not shown)
B= 50 ft, (15.24 m), Building Width (as shown)

Hr = 4.5 ft, (1.37 m) W2 = 337.5 kips, (1501.2 kN)


H2 = 8 ft, (2.44 m) (12.8-12)
H1 = 9 ft, (2.74 m) W1 = 375 kips, (1668.0 kN)
Seismic SDS = 0.96 (ASCE 7 Sec 11.4)
SD1 = 0.55 (ASCE 7 Sec 11.4)
S1 = 0.54 (ASCE 7 Sec 11.4)

Wind Exposure (B, C or D) C , (ASCE 7-16/10 26.7.3)


Wind Speed V= 145 mph, (233.35 kph)
(ASCE 7-16/10 26.5.1)

Base Shear (kips) Lateral Force (kips) Overturning (ft-kips)


Vb F1 F2 Mo
Seismic, ASD 75.2 27.8 47.3 1055.1
(0.11W) ( 0.07 Wx ) ( 0.14 Wx )
Wind, ASD 54.4 21.5 21.5 4673.8

Determine Seismic Factors


R= 6.5 (ASCE 7 Tab 12.2-1)
I= 1 (2018 IBC Tab 1604.5 & ASCE 7 11.5)
Ct = 0.02 (ASCE 7 Tab 12.8-2)
hn = 17.0 ft
x= 0.75 (ASCE 7 Tab 12.8-2)
T = Ct (hn) =
x
0.167 sec, (ASCE 7 Sec 12.8.2.1)

Determine Wind Factors


Kzt = 1 (ASCE 7-16/10 26.8 & Table 26.8-1)
Kd = 0.85 (ASCE 7-16/10 Tab. 26.6-1, for building)
G Cp i = 0.18 or -0.18 (ASCE 7-16/10 Tab. 26.11-1, Enclosed Building)
pmin = 16 psf (ASCE 7-16/10 28.4.4)
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
a= 5.00 ft (ASCE 7-16 Fig 28.3-1)
Kh = 0.89 (ASCE 7-16 26.10-1, pg 268)
qh = 40.83 psf (ASCE 7-16 Eq. 26.10-1 page 268)
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
One Story Comparison of Seismic and Wind Based on 2018 IBC / 2016 CBC

INPUT DATA & DESIGN SUMMARY


L= 150 ft, (45.72 m), Building Length (perpendicular, not shown)
B= 50 ft, (15.24 m), Building Width (as shown)

Hr = 4.5 ft, (1.37 m) W1 = 375 kips, (1668.0 kN)


H1 = 9 ft, (2.74 m) (12.8-12, half perpendicular wall)

Seismic SDS = 0.96 (ASCE 7 Sec 11.4)


SD1 = 0.55 (ASCE 7 Sec 11.4)
S1 = 0.54 (ASCE 7 Sec 11.4)

Wind Exposure (B, C or D) C , (ASCE 7-16/10 26.7.3)


Wind Speed V= 145 mph, (233.35 kph)
(ASCE 7-16/10 26.5.1)

Base Shear (kips) Lateral Force (kips) Overturning (ft-kips)


Vb F1 Mo
Seismic, ASD 39.6 39.6 356.0
(0.11W) ( 0.11 Wx )
Wind, ASD 24.8 8.3 4051.4

Determine Seismic Factors


R= 6.5 (ASCE 7 Tab 12.2-1)
I= 1 (2018 IBC Tab 1604.5 & ASCE 7 11.5)
Ct = 0.02 (ASCE 7 Tab 12.8-2)
hn = 9.0 ft
x= 0.75 (ASCE 7 Tab 12.8-2)
T = Ct (hn) =
x
0.104 sec, (ASCE 7 Sec 12.8.2.1)

Determine Wind Factors


Kzt = 1 (ASCE 7-16/10 26.8 & Table 26.8-1)
Kd = 0.85 (ASCE 7-16/10 Tab. 26.6-1, for building)
G Cp i = 0.18 or -0.18 (ASCE 7-16/10 Tab. 26.11-1, Enclosed Building)
pmin = 16 psf (ASCE 7-16/10 28.4.4)
a= 4.50 ft (ASCE 7-16 Fig 28.3-1)
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Kh = 0.85 (ASCE 7-16 26.10-1, pg 268)
qh = 38.89 psf (ASCE 7-16 Eq. 26.10-1 page 268)
PROJECT :
CLIENT :
JOB NO. : DATE :
Wind Analysis for Low-rise Building, Based on ASCE 7-2010

INPUT DATA
Exposure category (B, C or D, ASCE 7-10 26.7.3) C
Importance factor (ASCE 7-10 Table 1.5-2) Iw = 1.00 for all Category
Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC) V = 145 mph
Topographic factor (ASCE 7-10 26.8 & Table 26.8-1) Kzt = 1 Flat
Building height to eave he = 25 ft
Building height to ridge hr = 29.5 ft
Building length L = 150 ft
Building width B = 50 ft
Effective area of components (or Solar Panel area) A = 10 ft2

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
Max total upward force

ANALYSIS
Velocity pressure
qh = 0.00256 Kh Kzt Kd V2 = 43.83 psf
where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 pag
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)
h = mean roof height

Design pressures for MWFRS


p = qh [(G Cpf )-(G Cpi )]
where: p = pressure in appropriate zone. (Eq. 28.4-1, page 298). pmin =
G Cp f = product of gust effect factor and external pressure coefficient, see table below
G Cp i = product of gust effect factor and internal pressure coefficient.(Tab. 26.11-1, E
= 0.18 or -0.18
a = width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1B, 0.1L, 0.4h), M
Net Pressures (psf), Basic Load Cases
Roof angle q = 10.20 Roof angle q = 0.00
Surface Net Pressure with Net Pressure with
G Cp f G Cp f
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 0.45 11.62 27.40 -0.45 -27.61 -11.83
2 -0.69 -38.13 -22.35 -0.69 -38.13 -22.35
3 -0.41 -25.78 -10.00 -0.37 -24.11 -8.33
4 -0.34 -22.73 -6.95 -0.45 -27.61 -11.83
5 0.40 9.64 25.42
6 -0.29 -20.60 -4.82
1E 0.68 21.74 37.51 -0.48 -28.93 -13.15
2E -1.07 -54.79 -39.01 -1.07 -54.79 -39.01
3E -0.59 -33.55 -17.77 -0.53 -31.12 -15.34
4E -0.50 -29.93 -14.15 -0.48 -28.93 -13.15
5E 0.61 18.85 34.62
6E -0.43 -26.74 -10.96
Basic Load Case A (Transverse Direction) Basic Load Case B (Longitudin
Area Pressure (k) with Area
Surface Surface
(ft2) (+GCp i ) (-GCp i ) (ft2)
1 3500 40.67 95.89 2 3556
2 3556 -135.60 -79.49 3 3556
3 3556 -91.67 -35.56 5 1108
4 3500 -79.55 -24.32 6 1108
1E 250 5.43 9.38 2E 254
2E 254 -13.92 -9.91 3E 254
3E 254 -8.52 -4.51 5E 255
4E 250 -7.48 -3.54 6E 255
Horiz. 124.39 124.39 Horiz.
S S
Vert. -245.77 -127.43 Vert.
Min. wind Horiz. 70.80 70.80 Min. wind Horiz.
28.4.4 Vert. -120.00 -120.00 28.4.4 Vert.

Torsional Load Case A (Transverse Direction) Torsional Load Case


Area Pressure (k) with Torsion (ft-k)
Surface Surface
(ft )
2
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 1625 18.88 44.52 661 1558 2
2 1651 -62.96 -36.91 -390 -229 3
3 1651 -42.56 -16.51 264 102 5
4 1625 -36.93 -11.29 1293 395 6
1E 250 5.43 9.38 380 656 2E
2E 254 -13.92 -9.91 -173 -123 3E
3E 254 -8.52 -4.51 106 56 5E
4E 250 -7.48 -3.54 524 248 6E
1T 1875 5.45 12.84 -204 -482 5T
2T 1905 -18.16 -10.65 121 71 6T
3T 1905 -12.28 -4.76 -82 -32 Total Horiz. Tors
4T 1875 -10.65 -3.26 -400 -122
Total Horiz. Torsional Load, MT 2100 2100

Design pressures for components and cladding


p = qh[ (G Cp) - (G Cpi)]
where: p = pressure on component. (Eq. 30.4-1, pg 318)
pmin = 16.00 psf (ASCE 7-10 30.2.2)
G Cp = external pressure coefficient.
see table below. (ASCE 7-10 30.4.2)
Effective Zone 1 Zone 2 Zone 3
Area (ft )
2 GCP - GCP GCP - GCP GCP
Comp. 10 0.50 -0.90 0.50 -1.70 0.50

Comp. & Cladding Zone 1 Zone 2 Zone 3


Pressure Positive Negative Positive Negative Positive
( psf ) 29.80 -47.34 29.80 -82.40 29.80

Note: If the effective area is roof Solar Panel area, the only zone 1, 2 , or 3 apply
PAGE :
DESIGN BY :
REVIEW BY :

for all Category

= 124.39 kips, SD level (LRFD level), Typ.


= 45.11 kips
= 2099.61 ft-kips
= 245.77 kips

e 298 & Eq. 30.3-1 page 316)


t, h, (Tab. 28.3-1, pg 299) = 0.96
= 0.85
= 27.25 ft
< 60 ft, [Satisfactory] (ASCE 7-10 26.2.1)
< Min (L, B), [Satisfactory] (ASCE 7-10 26.2.2)

16 psf (ASCE 7-10 28.4.4)


efficient, see table below. (Fig. 28.4-1, page 300 & 301)
ficient.(Tab. 26.11-1, Enclosed Building, page 258)

MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] = 5.00 ft


Net Pressures (psf), Torsional Load Cases
Roof angle q = 10.20
Surface Net Pressure with
G Cp f
(+GCp i ) (-GCp i )
1T 0.45 2.90 6.85
2T -0.69 -9.53 -5.59
3T -0.41 -6.44 -2.50
4T -0.34 -5.68 -1.74
Roof angle q = 0.00
Surface Net Pressure with
G Cp f
(+GCp i ) (-GCp i )
5T 0.40 2.41 6.36
6T -0.29 -5.15 -1.21
ad Case B (Longitudinal Direction)
Pressure (k) with
(+GCp i ) (-GCp i )
-135.60 -79.49
-85.73 -29.61
10.68 28.17
-22.82 -5.34
-13.92 -9.91
-7.90 -3.90
4.80 8.81
-6.80 -2.79
45.11 45.11
-219.81 -101.45
21.80 21.80
-120.00 -120.00

Torsional Load Case B (Longitudinal Direction)


Area Pressure (k) with Torsion (ft-k)
(ft )
2
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
3556 -135.60 -79.49 -60 -35
3556 -85.73 -29.61 38 13
427 4.11 10.85 40 106
427 -8.79 -2.06 86 20
254 -13.92 -9.91 179 127
254 -7.90 -3.90 -102 -50
255 4.80 8.81 108 198
255 -6.80 -2.79 153 63
681 1.64 4.33 -20 -53
681 -3.51 -0.82 -43 -10
Total Horiz. Torsional Load, MT 379.6 379.6
Zone 3 Zone 4 Zone 5
- GCP GCP - GCP GCP - GCP
-2.60 1.00 -1.10 1.00 -1.40

Zone 3 Zone 4 Zone 5


Negative Positive Negative Positive Negative
-121.84 51.72 -56.10 51.72 -69.25

ly zone 1, 2 , or 3 apply.
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Three Story Seismic Analysis Based on 2012 IBC / 2013 CBC

Determine Base Shear (Derived from ASCE 7 Sec. 12.8 & Supplement 2)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W
= MAX{ MIN[ 0.38W , 0.15W ] , 0.04W , 0.00W } ^
= 0.15 W, (SD) (for S1 ≥ 0.6 g only)
= 0.11 W, (ASD) = 98.90 kips
Where SDS = 0.96 (ASCE 7 Sec 11.4.4)
SD1 = 0.55 (ASCE 7 Sec 11.4.4)
S1 = 0.54 (ASCE 7 Sec 11.4.1)
R= 6.5 (ASCE 7 Tab 12.2-1)
I= 1 (2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)
Ct = 0.02 (ASCE 7 Tab 12.8-2)
hn = 25.0 ft
x= 0.75 (ASCE 7 Tab 12.8-2)
T = Ct (hn) =
x
0.224 sec, (ASCE 7 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7, Sec 12.8.3 & 12.8.6)

Level Wx hx hxk Wxhxk Fx , ASD (12.8-11) d xe,allowable, ASD

Roof 225 25 25.0 5625 37.7 ( 0.17 Wx ) 0.3


3RD 337.5 17 17.0 5738 38.5 ( 0.11 Wx ) 0.3
2ND 375 9 9.0 3375 22.6 ( 0.06 Wx ) 0.4

937.5 14738 98.9

Where k = 1 for T <= 0.5 d xe,allowable, ASD = Da I / (1.4 Cd), (ASCE 7 Sec 12.8.6)
k = 0.5 T + 0.75 for T @ (0.5 , 2.5) Cd = 4 ,(ASCE 7 Tab 12.2-1)
k = 2 for T >= 2.5 Da = 0.02 hsx, (ASCE 7 Tab 12.12-1)

Calculate Diaphragm Forces (ASCE 7, Sec 12.10.1.1)


Level Wx SWx Fx SFx Fpx , ASD, (12.10-1)

Roof 225.0 225.0 37.7 37.7 37.7 ( 0.17 Wx )

3RD 337.5 562.5 38.5 76.3 45.8 ( 0.14 Wx )

2ND 375.0 937.5 22.6 98.9 48.0 ( 0.13 Wx )


937.5 98.9

Where Fmin = 0.2 SDS I Wx / 1.5 , ASD


Fmax = 0.4 SDS I Wx / 1.5 , ASD
PROJECT :
CLIENT :
JOB NO. : DATE :
Wind Analysis for Low-rise Building, Based on ASCE 7-2010

INPUT DATA
Exposure category (B, C or D, ASCE 7-10 26.7.3) C
Importance factor (ASCE 7-10 Table 1.5-2) Iw = 1.00 for all Category
Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC) V = 145 mph
Topographic factor (ASCE 7-10 26.8 & Table 26.8-1) Kzt = 1 Flat
Building height to eave he = 17 ft
Building height to ridge hr = 21.5 ft
Building length L = 150 ft
Building width B = 50 ft
Effective area of components (or Solar Panel area) A = 10 ft2

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
Max total upward force

ANALYSIS
Velocity pressure
qh = 0.00256 Kh Kzt Kd V2 = 40.83 psf
where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 pag
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)
h = mean roof height

Design pressures for MWFRS


p = qh [(G Cpf )-(G Cpi )]
where: p = pressure in appropriate zone. (Eq. 28.4-1, page 298). pmin =
G Cp f = product of gust effect factor and external pressure coefficient, see table below
G Cp i = product of gust effect factor and internal pressure coefficient.(Tab. 26.11-1, E
= 0.18 or -0.18
a = width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1B, 0.1L, 0.4h), M
Net Pressures (psf), Basic Load Cases
Roof angle q = 10.20 Roof angle q = 0.00
Surface Net Pressure with Net Pressure with
G Cp f G Cp f
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 0.45 10.82 25.52 -0.45 -25.72 -11.02
2 -0.69 -35.52 -20.82 -0.69 -35.52 -20.82
3 -0.41 -24.02 -9.32 -0.37 -22.46 -7.76
4 -0.34 -21.17 -6.47 -0.45 -25.72 -11.02
5 0.40 8.98 23.68
6 -0.29 -19.19 -4.49
1E 0.68 20.25 34.95 -0.48 -26.95 -12.25
2E -1.07 -51.04 -36.34 -1.07 -51.04 -36.34
3E -0.59 -31.26 -16.56 -0.53 -28.99 -14.29
4E -0.50 -27.88 -13.18 -0.48 -26.95 -12.25
5E 0.61 17.56 32.26
6E -0.43 -24.91 -10.21
Basic Load Case A (Transverse Direction) Basic Load Case B (Longitudin
Area Pressure (k) with Area
Surface Surface
(ft2) (+GCp i ) (-GCp i ) (ft2)
1 2380 25.76 60.75 2 3556
2 3556 -126.33 -74.06 3 3556
3 3556 -85.41 -33.13 5 788
4 2380 -50.40 -15.41 6 788
1E 170 3.44 5.94 2E 254
2E 254 -12.97 -9.23 3E 254
3E 254 -7.94 -4.21 5E 175
4E 170 -4.74 -2.24 6E 175
Horiz. 76.20 76.20 Horiz.
S S
Vert. -228.96 -118.72 Vert.
Min. wind Horiz. 51.60 51.60 Min. wind Horiz.
28.4.4 Vert. -120.00 -120.00 28.4.4 Vert.

Torsional Load Case A (Transverse Direction) Torsional Load Case


Area Pressure (k) with Torsion (ft-k)
Surface Surface
(ft )
2
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 1105 11.96 28.20 419 987 2
2 1651 -58.65 -34.38 -364 -213 3
3 1651 -39.65 -15.38 246 95 5
4 1105 -23.40 -7.15 819 250 6
1E 170 3.44 5.94 241 416 2E
2E 254 -12.97 -9.23 -161 -114 3E
3E 254 -7.94 -4.21 98 52 5E
4E 170 -4.74 -2.24 332 157 6E
1T 1275 3.45 8.14 -129 -305 5T
2T 1905 -16.92 -9.92 112 66 6T
3T 1905 -11.44 -4.44 -76 -29 Total Horiz. Tors
4T 1275 -6.75 -2.06 -253 -77
Total Horiz. Torsional Load, MT 1284 1284

Design pressures for components and cladding


p = qh[ (G Cp) - (G Cpi)]
where: p = pressure on component. (Eq. 30.4-1, pg 318)
pmin = 16.00 psf (ASCE 7-10 30.2.2)
G Cp = external pressure coefficient.
see table below. (ASCE 7-10 30.4.2)
Effective Zone 1 Zone 2 Zone 3
Area (ft )
2 GCP - GCP GCP - GCP GCP
Comp. 10 0.50 -0.90 0.50 -1.70 0.50

Comp. & Cladding Zone 1 Zone 2 Zone 3


Pressure Positive Negative Positive Negative Positive
( psf ) 27.77 -44.10 27.77 -76.76 27.77

Note: If the effective area is roof Solar Panel area, the only zone 1, 2 , or 3 apply
PAGE :
DESIGN BY :
REVIEW BY :

for all Category

= 76.20 kips, SD level (LRFD level), Typ.


= 29.61 kips
= 1284.13 ft-kips
= 228.96 kips

e 298 & Eq. 30.3-1 page 316)


t, h, (Tab. 28.3-1, pg 299) = 0.89
= 0.85
= 19.25 ft
< 60 ft, [Satisfactory] (ASCE 7-10 26.2.1)
< Min (L, B), [Satisfactory] (ASCE 7-10 26.2.2)

16 psf (ASCE 7-10 28.4.4)


efficient, see table below. (Fig. 28.4-1, page 300 & 301)
ficient.(Tab. 26.11-1, Enclosed Building, page 258)

MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] = 5.00 ft


Net Pressures (psf), Torsional Load Cases
Roof angle q = 10.20
Surface Net Pressure with
G Cp f
(+GCp i ) (-GCp i )
1T 0.45 2.71 6.38
2T -0.69 -8.88 -5.21
3T -0.41 -6.00 -2.33
4T -0.34 -5.29 -1.62
Roof angle q = 0.00
Surface Net Pressure with
G Cp f
(+GCp i ) (-GCp i )
5T 0.40 2.25 5.92
6T -0.29 -4.80 -1.12
ad Case B (Longitudinal Direction)
Pressure (k) with
(+GCp i ) (-GCp i )
-126.33 -74.06
-79.87 -27.59
7.08 18.66
-15.12 -3.54
-12.97 -9.23
-7.36 -3.63
3.06 5.63
-4.35 -1.78
29.61 29.61
-204.20 -96.25
15.40 15.40
-120.00 -120.00

Torsional Load Case B (Longitudinal Direction)


Area Pressure (k) with Torsion (ft-k)
(ft )
2
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
3556 -126.33 -74.06 -56 -33
3556 -79.87 -27.59 35 12
307 2.76 7.26 27 70
307 -5.89 -1.38 57 13
254 -12.97 -9.23 167 119
254 -7.36 -3.63 -95 -47
175 3.06 5.63 69 127
175 -4.35 -1.78 98 40
481 1.08 2.85 -13 -34
481 -2.31 -0.54 -28 -6
Total Horiz. Torsional Load, MT 261.0 261.0
Zone 3 Zone 4 Zone 5
- GCP GCP - GCP GCP - GCP
-2.60 1.00 -1.10 1.00 -1.40

Zone 3 Zone 4 Zone 5


Negative Positive Negative Positive Negative
-113.51 48.18 -52.27 48.18 -64.51

ly zone 1, 2 , or 3 apply.
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Two Story Seismic Analysis Based on 2012 IBC / 2013 CBC

Determine Base Shear (Derived from ASCE 7 Sec. 12.8 & Supplement 2)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W
= MAX{ MIN[ 0.51W , 0.15W ] , 0.04W , 0.00W } ^
= 0.15 W, (SD) (for S1 ≥ 0.6 g only)
= 0.11 W, (ASD) = 75.16 kips
Where SDS = 0.96 (ASCE 7 Sec 11.4.4)
SD1 = 0.55 (ASCE 7 Sec 11.4.4)
S1 = 0.54 (ASCE 7 Sec 11.4.1)
R= 6.5 (ASCE 7 Tab 12.2-1)
I= 1 (2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)
Ct = 0.02 (ASCE 7 Tab 12.8-2)
hn = 17.0 ft
x= 0.75 (ASCE 7 Tab 12.8-2)
T = Ct (hn) =
x
0.167 sec, (ASCE 7 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7, Sec 12.8.3 & 12.8.6)

Level Wx hx hxk Wxhxk Fx , ASD (12.8-11) d xe,allowable, ASD

Roof 337.5 17 17.0 5738 47.3 ( 0.14 Wx ) 0.3


2ND 375 9 9.0 3375 27.8 ( 0.07 Wx ) 0.4

712.5 9113 75.2

Where k = 1 for T <= 0.5 d xe,allowable, ASD = Da I / (1.4 Cd), (ASCE 7 Sec 12.8.6)
k = 0.5 T + 0.75 for T @ (0.5 , 2.5) Cd = 4 ,(ASCE 7 Tab 12.2-1)
k = 2 for T >= 2.5 Da = 0.02 hsx, (ASCE 7 Tab 12.12-1)

Calculate Diaphragm Forces (ASCE 7, Sec 12.10.1.1)


Level Wx SWx Fx SFx Fpx , ASD, (12.10-1)

Roof 337.5 337.5 47.3 47.3 47.3 ( 0.14 Wx )

2ND 375.0 712.5 27.8 75.2 48.0 ( 0.13 Wx )


712.5 75.2

Where Fmin = 0.2 SDS I Wx / 1.5 , ASD


Fmax = 0.4 SDS I Wx / 1.5 , ASD
PROJECT :
CLIENT :
JOB NO. : DATE :
Wind Analysis for Low-rise Building, Based on ASCE 7-2010

INPUT DATA
Exposure category (B, C or D, ASCE 7-10 26.7.3) C
Importance factor (ASCE 7-10 Table 1.5-2) Iw = 1.00 for all Category
Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC) V = 145 mph
Topographic factor (ASCE 7-10 26.8 & Table 26.8-1) Kzt = 1 Flat
Building height to eave he = 9 ft
Building height to ridge hr = 13.5 ft
Building length L = 150 ft
Building width B = 50 ft
Effective area of components (or Solar Panel area) A = 10 ft2

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
Max total upward force

ANALYSIS
Velocity pressure
qh = 0.00256 Kh Kzt Kd V2 = 38.89 psf
where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 pag
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)
h = mean roof height

Design pressures for MWFRS


p = qh [(G Cpf )-(G Cpi )]
where: p = pressure in appropriate zone. (Eq. 28.4-1, page 298). pmin =
G Cp f = product of gust effect factor and external pressure coefficient, see table below
G Cp i = product of gust effect factor and internal pressure coefficient.(Tab. 26.11-1, E
= 0.18 or -0.18
a = width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1B, 0.1L, 0.4h), M
Net Pressures (psf), Basic Load Cases
Roof angle q = 10.20 Roof angle q = 0.00
Surface Net Pressure with Net Pressure with
G Cp f G Cp f
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 0.45 10.31 24.31 -0.45 -24.50 -10.50
2 -0.69 -33.83 -19.83 -0.69 -33.83 -19.83
3 -0.41 -22.87 -8.87 -0.37 -21.39 -7.39
4 -0.34 -20.17 -6.17 -0.45 -24.50 -10.50
5 0.40 8.56 22.55
6 -0.29 -18.28 -4.28
1E 0.68 19.29 33.28 -0.48 -25.67 -11.67
2E -1.07 -48.61 -34.61 -1.07 -48.61 -34.61
3E -0.59 -29.77 -15.77 -0.53 -27.61 -13.61
4E -0.50 -26.55 -12.56 -0.48 -25.67 -11.67
5E 0.61 16.72 30.72
6E -0.43 -23.72 -9.72
Basic Load Case A (Transverse Direction) Basic Load Case B (Longitudin
Area Pressure (k) with Area
Surface Surface
(ft2) (+GCp i ) (-GCp i ) (ft2)
1 1269 13.08 30.85 2 3582
2 3582 -121.18 -71.03 3 3582
3 3582 -81.92 -31.78 5 478
4 1269 -25.59 -7.83 6 478
1E 81 1.56 2.70 2E 229
2E 229 -11.11 -7.91 3E 229
3E 229 -6.81 -3.61 5E 85
4E 81 -2.15 -1.02 6E 85
Horiz. 34.67 34.67 Horiz.
S S
Vert. -217.52 -112.52 Vert.
Min. wind Horiz. 32.40 32.40 Min. wind Horiz.
28.4.4 Vert. -120.00 -120.00 28.4.4 Vert.

Torsional Load Case A (Transverse Direction) Torsional Load Case


Area Pressure (k) with Torsion (ft-k)
Surface Surface
(ft )
2
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
1 594 6.12 14.44 216 509 2
2 1677 -56.72 -33.25 -354 -208 3
3 1677 -38.35 -14.88 239 93 5
4 594 -11.98 -3.66 422 129 6
1E 81 1.56 2.70 110 190 2E
2E 229 -11.11 -7.91 -139 -99 3E
3E 229 -6.81 -3.61 85 45 5E
4E 81 -2.15 -1.02 152 72 6E
1T 675 1.74 4.10 -65 -154 5T
2T 1905 -16.11 -9.45 107 63 6T
3T 1905 -10.89 -4.23 -72 -28 Total Horiz. Tors
4T 675 -3.40 -1.04 -128 -39
Total Horiz. Torsional Load, MT 573 573

Design pressures for components and cladding


p = qh[ (G Cp) - (G Cpi)]
where: p = pressure on component. (Eq. 30.4-1, pg 318)
pmin = 16.00 psf (ASCE 7-10 30.2.2)
G Cp = external pressure coefficient.
see table below. (ASCE 7-10 30.4.2)
Effective Zone 1 Zone 2 Zone 3
Area (ft )
2 GCP - GCP GCP - GCP GCP
Comp. 10 0.50 -0.90 0.50 -1.70 0.50

Comp. & Cladding Zone 1 Zone 2 Zone 3


Pressure Positive Negative Positive Negative Positive
( psf ) 26.44 -42.00 26.44 -73.11 26.44

Note: If the effective area is roof Solar Panel area, the only zone 1, 2 , or 3 apply
PAGE :
DESIGN BY :
REVIEW BY :

for all Category

= 34.67 kips, SD level (LRFD level), Typ.


= 16.25 kips
= 573.16 ft-kips
= 217.52 kips

e 298 & Eq. 30.3-1 page 316)


t, h, (Tab. 28.3-1, pg 299) = 0.85
= 0.85
= 11.25 ft
< 60 ft, [Satisfactory] (ASCE 7-10 26.2.1)
< Min (L, B), [Satisfactory] (ASCE 7-10 26.2.2)

16 psf (ASCE 7-10 28.4.4)


efficient, see table below. (Fig. 28.4-1, page 300 & 301)
ficient.(Tab. 26.11-1, Enclosed Building, page 258)

MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] = 4.50 ft


Net Pressures (psf), Torsional Load Cases
Roof angle q = 10.20
Surface Net Pressure with
G Cp f
(+GCp i ) (-GCp i )
1T 0.45 2.58 6.08
2T -0.69 -8.46 -4.96
3T -0.41 -5.72 -2.22
4T -0.34 -5.04 -1.54
Roof angle q = 0.00
Surface Net Pressure with
G Cp f
(+GCp i ) (-GCp i )
5T 0.40 2.14 5.64
6T -0.29 -4.57 -1.07
ad Case B (Longitudinal Direction)
Pressure (k) with
(+GCp i ) (-GCp i )
-121.18 -71.03
-76.61 -26.46
4.09 10.78
-8.73 -2.04
-11.11 -7.91
-6.31 -3.11
1.42 2.60
-2.01 -0.82
16.25 16.25
-195.24 -94.21
9.00 9.00
-120.00 -120.00

Torsional Load Case B (Longitudinal Direction)


Area Pressure (k) with Torsion (ft-k)
(ft )
2
(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )
3582 -121.18 -71.03 -48 -28
3582 -76.61 -26.46 31 11
197 1.68 4.43 16 43
197 -3.59 -0.84 35 8
229 -11.11 -7.91 143 102
229 -6.31 -3.11 -81 -40
85 1.42 2.60 32 59
85 -2.01 -0.82 46 19
281 0.60 1.59 -7 -19
281 -1.29 -0.30 -15 -4
Total Horiz. Torsional Load, MT 151.1 151.1
Zone 3 Zone 4 Zone 5
- GCP GCP - GCP GCP - GCP
-2.60 1.00 -1.10 1.00 -1.40

Zone 3 Zone 4 Zone 5


Negative Positive Negative Positive Negative
-108.11 45.89 -49.78 45.89 -61.44

ly zone 1, 2 , or 3 apply.
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
One Story Seismic Analysis Based on 2012 IBC / 2013 CBC

Determine Base Shear (Derived from ASCE 7 Sec. 12.8 & Supplement 2)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W
= MAX{ MIN[ 0.81W , 0.15W ] , 0.04W , 0.00W } ^
= 0.15 W, (SD) (for S1 ≥ 0.6 g only)
= 0.11 W, (ASD) = 39.56 kips
Where SDS = 0.96 (ASCE 7 Sec 11.4.4)
SD1 = 0.55 (ASCE 7 Sec 11.4.4)
S1 = 0.54 (ASCE 7 Sec 11.4.1)
R= 6.5 (ASCE 7 Tab 12.2-1)
I= 1 (2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)
Ct = 0.02 (ASCE 7 Tab 12.8-2)
hn = 9.0 ft
x= 0.75 (ASCE 7 Tab 12.8-2)
T = Ct (hn) =
x
0.104 sec, (ASCE 7 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7, Sec 12.8.3 & 12.8.6)

Level Wx hx hxk Wxhxk Fx , ASD (12.8-11) d xe,allowable, ASD


Roof 375 9 9.0 3375 39.6 ( 0.11 Wx ) 0.4
375.0 3375 39.6

Where k = 1 for T <= 0.5 d xe,allowable, ASD = Da I / (1.4 Cd), (ASCE 7 Sec 12.8.6)
k = 0.5 T + 0.75 for T @ (0.5 , 2.5) Cd = 4 ,(ASCE 7 Tab 12.2-1)
k = 2 for T >= 2.5 Da = 0.02 hsx, (ASCE 7 Tab 12.12-1)

Calculate Diaphragm Forces (ASCE 7, Sec 12.10.1.1)


Level Wx SWx Fx SFx Fpx , ASD, (12.10-1)
Roof 375.0 375.0 39.6 39.6 48.0 ( 0.13 Wx )
375.0 39.6

Where Fmin = 0.2 SDS I Wx / 1.5 , ASD


Fmax = 0.4 SDS I Wx / 1.5 , ASD

You might also like