MATERIALS
CVE 549
Nov 28th, 2007.
Richard Brown
Chemical Engineering
URI
Degradation of Materials.
Metals – except for noble metals, they
tend to corrode in wet environments.
Current Density
1 10 2
icrit µA/cm
Pourbaix Diagram for Iron
Potential – pH diagrams indicate the
combination of electrochemical and
environmental conditions where
unstable and stable films form and
where metals are immune to
corrosion by remaining as an
element rather than reacting to form
an ion.
The Fe region is a region of
immunity.
Fe2+ and 3+ regions represent
corrosion.
Fe(OH)2 and Fe2O3 are passive
regions.
The dashed lines represent where
water will try to initiate corrosion.
Concrete at pH 12.5 falls in a
passive region. (0V SCE and pH
12.5)
Uniform Corrosion
Damp wet environment
initiates corrosion of poorly
painted steel tank. Looks bad,
bud as long as a large area
corrodes, then rate of
penetration low.
Pitting and Crevice Corrosion
Crevice and Pitting Corrosion.
Localized Corrosion.
Oxides become unstable due to
halides, local attack using same
reactions.
Initiation Site.
Corrosion Rates
Uniform or Galvanic Only.
• CR = 0.13 (icorr x EW)
d
• for units of Corr Rate in mils per year, icorr
in mA.cm-2
• EW is the equivalent weight and d is the
density of the metal.
• icorr data available from lab testing.
Laboratory Data for icorr
Polarization Data
-0.45
Cathode
Reaction
Potentiodynamic test run to find
-0.47
Anode Reaction icorr data from extrapolation.
Potential V (SCE)
-0.49
-0.51
-0.55
.1 1 10 100
log Current Density
microamps per centimeter squared
Polarization Data
-0.45
-0.49
-0.51
-0.53
-0.55
.1 1 10 100
log Current Density
microamps per centimeter squared
Salt Spray Testing ASTM B117
Salt water Deionzed Water
Salt fog
Water tower and heater Untested steel, steel 1 and steel 2 tested
Salt spray unit, 5% NaCl at 95F and for same time. Steel 2 is best choice.
100% humidity.
Using Corrosion
0.5
0
-0.5
-1
-1.5
-8 -6 -4 -2 0 2 4 6
2
Log i (uA/cm )
Electrochemical Impedance
Spectroscopy
Long term data available and passive circuit modeling for quantitative analysis
30 days exposure
5.5pH conversion coating
Bare sample
Interfacial failure was between the conventional chromate surface treatment and the Ti-6Al-4V alloy
conventional treatment
peroxide-titanate treatment First ply failure after 6 weeks with URI
fit (conventional treatment) non chromate treatment
7000 fit (peroxide-titanate treatment)
6000
5000
4000
3000
2000
1000
N u mb e r o f W e e k s
Voltage between carbon fiber and URI treatment 0.07V
Removal of galvanic component increased durability of
Failure loads for lap joints after marine exposure.
joint
Why Lamposts Fall.
Lamposts – Failed Coupling
Lamposts - Corrosion Evidence
Changing from cast alloy to wrought alloy with copper additionsinduced pitting corrosion
Cast Iron Coupling
with Resistance Plate
Polymer Degradation
Ultra Violet exposure – embrittles polymer, these days use clear coats which stop the
process.
Water uptake – polymers such as vinyl esters absorb 1.5% by weight of water can cause
imbalance in propellers.