Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

CASE-1

SubCase-1: C=100 SubCase-2: C=130


Specified Data
l = length of pipe (m) 270000 l = length of pipe (m) 270000
c= Hazen-Williams roughness constant 100 c= Hazen-Williams roughness constant 130
q = volume flow (liter/sec) 10856.7 q = volume flow (liter/sec) 10856.7
dh = inside or hydraulic diameter (mm) 3200 dh = inside or hydraulic diameter (mm) 3200

Calculated Pressure Loss Calculated Pressure Loss


f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe) 62.54 f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe) 38.47
f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe) 0.61 f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe) 0.38
Minor loss(loss at junstions, valves etc., 10% of friction loss assumed)= 16.89 Minor loss(loss at junstions, valves etc., 10% of friction loss assumed)= 10.39
Head loss (m H20) 168.85945 Head loss (m H20) 103.8729
Head loss (kPa) 1.66 Head loss (kPa) 1.02

Calculated Flow Velocity Calculated Flow Velocity


v = flow velocity (m/s) 1.35 v = flow velocity (m/s) 1.35

Q=1917 cusec ( 5 Rows of 3.2 m dia MS Pipe), Q(per pipe)= 1917/5= 383.4 cusec=
1086.4 lit/sec.

SubCase 1: Total head loss=Head loss due to pipe friction + Minor losses( 10% of SubCase 2:Total head loss=Head loss due to pipe friction + Minor losses( 10% of
pipe friction loss Assumed) pipe friction loss Assumed)

Total head loss (m) 185.745397 Total head loss (m) 114.2602
FSL
334.2 m offtake
level (At
Tajewala:)
Net Head :
334.2- Ht. above
231.7= ground
Storage level: 5.7 m
270 Km Storage
102.5 m Resevoir FRL:
Reservoir
(At 226+5.7=
Jhunjhun) 231.7 m EL: 226 m

CASE-2: With net head: 102.5m , allowable discharge in each pipeline


SubCase-1: C=100 SubCase-2: C=130
Specified Data
l = length of pipe (m) 270000 l = length of pipe (m) 270000
c= Hazen-Williams roughness constant 100 c= Hazen-Williams roughness constant 130
q = volume flow (liter/sec) 7875.6087 q = volume flow (liter/sec) 10238.29
dh = inside or hydraulic diameter (mm) 3200 dh = inside or hydraulic diameter (mm) 3200

Calculated Pressure Loss Calculated Pressure Loss


f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe) 34.51 f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe) 34.51
f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe) 0.34 f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe) 0.34
Minor loss(loss at junstions, valves etc., 10% of friction loss assumed)= 9.32 Minor loss(loss at junstions, valves etc., 10% of friction loss assumed)= 9.32
Head loss (m H20) 93.181819 Head loss (m H20) 93.18182
Head loss (kPa) 0.91 Head loss (kPa) 0.91
Total head loss( m H20) 102.50 Total head loss( m H20) 102.50
Calculated Flow Velocity Calculated Flow Velocity
v = flow velocity (m/s) 0.98 v = flow velocity (m/s) 1.27

Q(Allowable)=1390.6 cusec, ( 5 Rows of 3.2 m dia MS Pipe), Q(per pipe)= Q(Allowable)=1807.75 cusec, ( 5 Rows of 3.2 m dia MS Pipe), Q(per
1917/5= 278.12 cusec= 7875.61 lit/sec. pipe)= 1917/5=361.55 cusec= 10238 lit/sec.
Total head loss=Head loss due to pipe friction + Minor losses( 10% of pipe friction Total head loss=Head loss due to pipe friction + Minor losses( 10% of pipe friction
loss Assumed) loss Assumed)
Total head loss (m) 102.5 Total head loss (m) 102.5

CASE-3: Size of pipeline required for actual discharge of 1917 cusec


Subcase1: C=100 Subcase2: C=130
Specified Data
l = length of pipe (m) 270000 l = length of pipe (m) 270000
c= Hazen-Williams roughness constant 100 c= Hazen-Williams roughness constant 130
q = volume flow (liter/sec) 10856.7 q = volume flow (liter/sec) 10856.7
dh = inside or hydraulic diameter (mm) 3615.8989 dh = inside or hydraulic diameter (mm) 3272.239
say 3700 mm say 3300 mm
Calculated Pressure Loss Calculated Pressure Loss
f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe) 34.51 f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe) 34.51
f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe) 0.34 f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe) 0.34
Minor loss(loss at junstions, valves etc., 10% of friction loss assumed)= 9.32 Minor loss(loss at junstions, valves etc., 10% of friction loss assumed)= 9.32
Head loss (m H20) 93.181839 Head loss (m H20) 93.18185
Total head loss( m H20) 102.50 Total head loss( m H20) 102.50
Head loss (kPa) 0.91 Head loss (kPa) 0.91

Calculated Flow Velocity Calculated Flow Velocity


v = flow velocity (m/s) 1.06 v = flow velocity (m/s) 1.29

Q=1917 cusec ( 5 Rows of 3.2 m dia MS Pipe), Q(per pipe)= 1917/5= 383.4 cusec=
1086.4 lit/sec.
SubCase 2: Total head loss=Head loss due to pipe friction + Minor losses( 10% of SubCase 2: Total head loss=Head loss due to pipe friction + Minor losses( 10% of
pipe friction loss Assumed) pipe friction loss Assumed)
Total head loss (m) 102.500023 Total head loss (m) 102.50003

You might also like