Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Archive Details

Archive Name PEMA0009920180904REC16 - Type X-5-16-


2019.xlsx
Archive Generated Date 5/16/2019 6:13:07 AM (UTC)
Archive Comment
Certification Group PEMA0009920180904REC16 - Type X
Certification Type Completions Workover
Certification Group Status Active
BU IBU-SMO

People
Certification Group Engineers Muhammad Rusydi (NYLU);Dhimas Rahardjo
(DVZH)

Well Engineers

Certification Group Examiners Iwan Wijanarko (IWWI)

Wells
Certification Group Wells PEMA00099

Linked OQEs
Completion/Workover Program ACS-
006_Well%20Program_PEMA0009920180904RE
C16.docx
Basis of Design (BOD)
Approvals
From (DRAFT) to (APPROVED) 02-Apr-19
Sequence Role (Action Type) Action Date
1 EAR Checklist Approval (Approve)
1.1 Dhimas Rahardjo / D&C Engineer Approved 29-Mar-19
1.2 Waluyo Aji / D&C Operations Team Lead Approved 29-Mar-19
1.3 Nanang Lutfi Hamdani / D&C Engineering Team Lead Approved 01-Apr-19
2 EAR CHECLIST APPROVAL (Approve)
2.1 Iwan Wijanarko / WELLSAFE Examiner Approved 02-Apr-19
From (APPROVED) to (DRAFT) 10-May-19
From (DRAFT) to (APPROVED) 16-May-19
Sequence Role (Action Type) Action Date
1 EAR Checklist Approval (Approve)
1.1 Dhimas Rahardjo / D&C Engineer Approved 10-May-19
1.2 Nanang Lutfi Hamdani / D&C Engineering Team Lead Approved 14-May-19
1.3 Alex Hasmi / D&C Operations Team Lead Approved 15-May-19
2 EAR CHECKLIST APPROVAL (Approve)
2.1 Iwan Wijanarko / WELLSAFE Examiner Approved 16-May-19
WELLSAFE Execution Assurance Requirements Checklist
WSEA
WELLBORE SECTION PEMA00099
Ref No. Plan Data Actual Status Comment
1 Basic Well Data at Spud
Rig Name Rig ACS-017
Current RKB Elevation, ft 19
Ground Elevation, ft 80.9
Water Depth, ft 0
Slot Number -
Field Name Pematang
Area Bekasap North
1-A
Surface UWI PEMA00099
Lat/Long Datum ID74
Latitude 1° 16' 52.405" N
Longitude 101° 4' 38.214" E
Map Projection Type Universal Transverse Mercator
Map zone Zone 47N
Job spud date 30 March 2019
2 Pre-Spud Meeting
Conduct Pre-Job & Pre Tour Meeting :
The Well Control Risks identified and associated Safeguards including Safeguards
2-A
listed on the WSEA #3 shall be discussed in a rig-site Pre-Operations Meeting with all
crews
3 Well Control Safeguards
Killing the well properly before commencing Workover Operation
(No flow when pump OFF and 0 psi when well shut in) : - Annulus pressure & SITP
must be 0 psi and confirmed dead after “sufficient time” of observation before
3-A
commencing workover job
- Record Annulus pressure and SITP in Wellview report
- Cancel the Workover job if killing problem occurred

Maintain Primary Well Control at all time


(No flow when pump OFF and 0 psi when well shut in) :
3-B - Keep the wellbore full or if the well losses, keep pumping the well and record pump
rate & total volume pumped in Wellview.
- Must have continuous water supply.

Offset Injector Wells Management Plan :


- Offset Injector Wells that potentially to be shut in if well control event occurred:
3-C PM064 (331m)
- Report the status of the injector wells (ON/OFF) & record the Surface Pressure in
Wellview report (if pressure gauge is installed)

6 Casing/Tubing Test Pressures


Test fluid Density, ppg
Applied Surface Pressure, psi
Test Production casing
8 1/2" hole, 7" Production (The pressure test value is provided in the Detailed
6-A
Casing Work Program) : Test to 500 psi + MASP for 15 mins.
Comment 5% decline allowed.
- The test may be done along with MIT / Injection
packer test
- Recorded on Barton chart
8 BOP Configuration
BOP Stack for SLO Workover Operation:
- Class III BOP Stack
- If MASP > 2000 Psi, shall use shear ram
8-A BOP Configuration from top down:
- 3K-7 1/16" or 11" Annular
- 3K-7 1/16" or 11" Shear Blind or Blind Ram
- 3K-7 1/16" or 11" Pipe Ram (Ram must be same w/ Tubing size)
8-B BOP Stack for HO Workover Operation:
9 BOP Tests
Accumulator Drawdown & Pump Up Performance Test. - Perform Accumulator
Drawdown and Pump up Performance Test every nipple up BOPE or any repairs that
9-A required isolation/ partial isolation of the system. - WSM shall record the result in
Wellview report. The result shall include: Remained accumulator pressure after the
drawdown test, Pump up test result and also the closing time.
BOPE Testing after initial Rig Up
(The high pressure test value is provided in the Detailed Work Program)
- Test BOPE to 250 - 350 psi (low) & 500 psi + MASP (high) or the highest pressure be
applied against BOP hold 5 minutes for each test.
9-B
Note:
- If BOPE test conducted on stump test facility, then function test all preventer & BOP
stack connection test shall be conducted each N/U on wellhead.
- All testing shall be recorded on Barton Chart& reported on wellview.
9-C BOPE Testing after Installing casing head, tubing spool, and or adaptor/retrofitting
10 Barrier Tests
Lubricator & Stuffing Box
Component (The pressure test value is provided in the Detailed
Work Program)
Test fluid Density, ppg 8.33
Applied Surface Pressure, psi 1000
10-A
- Test to 1000 psi or 80% of the lowest RWP for 5
minutes (offline test at frequency not to exceed every
Comment 21 days)
- Report the test result in WellView & record on
Barton Chart
Connection Lubricator & BOP
Component (The pressure test value is provided in the Detailed
Work Program)
Test fluid Density, ppg 8.33
10-B
10-B
Applied Surface Pressure, psi
Pressure test to 500 psi + MASP for 5 minutes
Comment - Report the test result in WellView & record on
Barton Chart
Quick Test Connection Sub before every perforation
job
Component
(The pressure test value is provided in the Detailed
Work Program)
10-C Test fluid Density, ppg 8.33
Applied Surface Pressure, psi
'- Pressure test to 500 psi + MASP for 5 minutes
Comment
- Report the test result in WellView
Component Bridge plug/packer plug/cement plug
Test fluid Density, ppg 8.33
Applied Surface Pressure, psi 1000
Test to 1000 psi for 15 mins 5% decline / 30 mins 10%
10-D
decline allowed
- Test to 1000 psi for 30 mins 10% decline allowed (for
Comment
>5000' MD)
- Report the test result in WellView & record on
Barton Chart
Wellhead Connection Assembly
Component (The pressure test value is provided in the Detailed
Work Program)
Test fluid Density, ppg 8.33
10-E
Applied Surface Pressure, psi
- Test against casing and packer plug to 500 psi +
Comment MASP hold for 5 minutes after testing BOP.
- Record the test result on Barton Chart
Swab Head
Component (The pressure test value is provided in the Detailed
Work Program)
Test fluid Density, ppg 8.33
10-F
Applied Surface Pressure, psi
- Pressure test to 500 psi + MASP hold 5 mins.
Comment - Report the test result in WellView & record on
Barton Chart
Component Production/Injection Packer Test
Test fluid Density, ppg 8.33
Applied Surface Pressure, psi 1000
Test to 1000 psi for 15 mins 5% decline / 30 mins 10%
10-G
decline allowed
- Test to 1000 psi for 30 mins 10% decline allowed (for
Comment
>5000' MD)
- Report the test result in WellView & record on
Barton Chart
Tubing Hanger Seal
Component (The pressure test value is provided in the Detailed
Work Program)
Test fluid Density, ppg 8.33
10-H Applied Surface Pressure, psi

- Pressure test to 500 psi + MASP and hold 5 mins.


Comment - Report the test result in WellView & record on
Barton Chart
Tubing Hanger Seal
Component
(Non Mandrel Type)
Test fluid Density, ppg
Applied Surface Pressure, psi

- The existing tubing hanger on the well is “Non


Mandrel ESP Cable Penetrator" and it will be re-used.
- Pressure Test the Tubing Hanger is not required if
10-I
the well condition meet the criteria described in the
MOCP-18-001D:
Comment ● MASP = 0 PSI
● Non gas producer wells & GOR < 400 SCF/BBL
● No LOC/HES issues with individual or surrounding
adjacent wells
Report if the well condition meet with the above
criteria
Must use ESP Flat Power Cable #1
Component
(Non Mandrel Type tubing hanger)
Test fluid Density, ppg
10-J
Applied Surface Pressure, psi
Report the cable type in Wellview (refer to MOCP-18-
Comment
001D)
Must change out tubing hanger seals
Component
(Non Mandrel Type tubing hanger)
Test fluid Density, ppg
10-K
Applied Surface Pressure, psi
Report the activity in Wellview (refer to MOCP-18-
Comment
001D)
Xmas Tree (All Tree Valves, Tree Connections, Stuffing
Box, or Sample Cock whichever applicable)
Component
(The pressure test value is provided in the Detailed
Work Program)
Test fluid Density, ppg 8.33
10-L
Applied Surface Pressure, psi 700
'- Test to 500 psi + MASP and hold 5 mins.
- Report the test result in WellView & record on
Comment Barton Chart
Note: For SRP wells, tree connection tested along with
pump test.