ELECTRICAL ARC FLASH

HAZARD STUDY

APRIL 2008

Industry Division
División Industria
Your success
Su éxito is our
es nuestro aim
objetivo
VIDEO – LIBERATION OF ENERGY

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
AGENDA

Topics to Covering:

„ Electrical Arch
„ We are exposed?
„ Applicable Regulations
ArcFlash „ Risks
Estudio
Study ofde Riesgos
Risks
„ Incidents
„ Arc Flash Study

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ArcFlash
What´s this?

Direct contact
Traffic of current
Electrical across the body for Indirect contact
Accident

ArcFlash

ArcFlash It is a short circuit across the air, produced when :


Estudio
Study ofde Riesgos
Risks
„ The insulation between two energized drivers collapses
„ The same between a wire and earth, provoking an explosion for the
liberation of energy

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
VIDEO II – ARC in 500 kV

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
Accidents of ArcFlash
Where they can happen ?

Areas with High


Risk of Occurrence

Distributions Center Electrical Areas with


Panels Control of Engines high
Engines temperatures
MV / LV

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
Our Offer
His Purpose ….

The Purpose of
Our Study

„ To minimize the ocurrence and consequence of accidents


for ArcFlash
„ To determine reliable procedures of operation
ArcFlash
Estudio
Study ofde Riesgos
Risks
„ To define levels of appropiate PPE
„ To normalize a program of permanent training

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
¿WE ARE EXPOSED?

¿WE ARE
ArcFlash
Estudio
Study ofde Riesgos
Risks EXPOSED?
Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
¿WE ARE EXPOSED?

ArcFlash
Estudio
Study ofde Riesgos
Risks

Isn’t this a common situation in your plant?

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
¿WE ARE EXPOSED?

ArcFlash
Estudio
Study ofde Riesgos
Risks

Isn’t this a common situation in your plant?

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
¿WE ARE EXPOSED?

ArcFlash
Estudio
Study ofde Riesgos
Risks

Isn’t this a common situation in your plant?


Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ARC FLASH REASONS

„ The contact with parts under voltage for fall of tools

„ Insulations fault

„ Overvoltage

„ Dirt
ArcFlash
Estudio
Study ofde Riesgos
Risks
„ Corrosion

„ Condensation

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
NORMS

NORMS
ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ARCFLASH
Applicable Regulations

Applicable Regulations :

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ARCFLASH
Applicable Regulations

Applicable Regulations :

„ NFPA 70E Part II Articles 110 and 130


require a flash hazard analysis be performed
to protect qualified electrical personnel

ArcFlash „ NationalElectrical Code NFPA 70 Article


Estudio
Study ofde Riesgos
Risks
110.16 requires equipment be marked to warn
personnel of arc flash hazards

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ARCFLASH
Applicable Regulations

Applicable Regulations :

„ OSHA 29CFR1910.269(I)(6) discusses


appropriate PPE apparel to protect against
arc flash hazards

„ The 2004’ s version of IEEE 1584a


ArcFlash provides precise methods for ArcFlash 's
Estudio
Study ofde Riesgos
Risks calculation.

„ Procedures and safeties measurements specified


by each company
Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
RISKS

RISKS
ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
Electrical Arc Flash Hazards

„ Produce thermal energy that is released during a fault


and is a function of:

„ Available fault current and system voltage


„ Distance from fault
„ Clearing time of protective device

ArcFlash „ May generate higher energy at lower system voltages


Estudio
Study ofde Riesgos
Risks
(due to longer time arc fault current duration)

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
TYPES OF RISKS FOR ARC FLASH

There are principally five ways in which an electrical


ArcFlash can to cause damage and even the death:

„ Thermal Risk

„ Risk of Pressure

ArcFlash „ Risk of Hearing


Estudio
Study ofde Riesgos
Risks

„ Risk for Missiles

„ Risk for Inhalation

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ARCO ELECTRICO

Molten Metal
20.000 °C

Waves of Pressure

Waves of sound

Steam of Copper: Missil


ArcFlash
Estudio
Study ofde Riesgos
Risks
Occurred to
Steam It expands
Warm air
to factor of
Rapid expansion
67.000 times
Intense Light

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
INCIDENTS of ARCFLASH

INCIDENTS
ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
INCIDENTES POR ARCFLASH

ArcFlash
Estudio de Riesgos

División Industria
Su éxito es nuestro objetivo
INCIDENT for ARCFLASH

ArcFlash’ s Incident

System of 480Volt

22,600 Amper Symmetrical Current

Panel of Motor’s Control


ArcFlash
Estudio
Study ofde Riesgos
Risks

It comes out of 6 cycles (0.1 sec)

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ArcFlash
Estudio de Riesgos

División Industria
Su éxito es nuestro objetivo
RESULT OF AN ACCIDENT FOR
ARCFLASH

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
INCIDENT for ARCFLASH

INCIDENT for ARCFLASH

480 Volt System

22,600 22,600A Symmetrical Current


Panel of Motor’s Control

Limiter equipment with < ½ cycle of operation (.0083 sec).


ArcFlash
Estudio
Study ofde Riesgos
Risks To notice that the exhaust will have to be kept in the range

of limit of current

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ArcFlash
Estudio de Riesgos

División Industria
Su éxito es nuestro objetivo
VIDEO

ARC FLASH ’s INCIDENT


ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
VIDEO

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
AGENDA

ARC FLASH
ArcFlash
Estudio
Study ofde Riesgos
Risks
STUDY
Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
WHAT IS A STUDY OF RISK FOR ARC FLASH?

Definition:

„ The NFPA 70E defines a study of


risks for ArcFlash as :

“A study where is investigated the potential exhibition


of a workman to the energy caused by an electrical
arch
With the aim of:
ArcFlash
Estudio
Study ofde Riesgos
Risks ¾ To anticipate injuries ,

¾ To determine sure procedures of operation ,

¾ Levels of appropriate PPE .”

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
WHAT IS THE MINIMAL DISTANCE OF
PROTECTION ?

Definition:

„ The NFPA 70E defines a minimal distance of protection as:

“Distance, from the critical point, inside which a


person can suffer burns of second degree due to
an accident for Arc Flash .”

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
PPE as cal/cm2

PPE Selection
Protective Clothing Guidelines, from “Predicting Incident Energy to Better Manage the Electric Arc Hazard on 600-
V Power Distribution Systems,” Table III, IEEE Transactions on Industry Applications, Jan./Feb. 2000
Proposed Protective Clothing Classes FR Clothing System
Range of Calculated Incident Clothing Total Weight
Energy (cal/cm²) Class No. Clothing Description, (No. of Layers) (oz/yd²)
0–2 0 Untreated Cotton (1) 4.5 – 7
2-5 1 FR Shirt and Pants (1) 4.5 - 8

5-8 2A Cotton Underwear plus FR Shirt and Pants (2) 9 - 12

ArcFlash 5 - 16 2B FR Underwear plus FR Shirt and Pants (2) 10 - 14


Estudio
Study ofde Riesgos
Risks Cotton Underwear plus FR Shirt and Pants plus
8 - 25 3 16 - 20
FR Coverall (3)
Cotton Underwear plus FR Shirt and Pants plus
25 - 40 4 24 - 30
Double Layer Switching Coat (4)

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
Flash hazard label
(one per analysis point)

ArcFlash
Estudio
Study ofde Riesgos
Risks

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
Electrical Arc Flash Hazard Study

Customer to Provide:
„ One line diagram of power delivery
system
„ Current copy of power system short
circuit study and coordination study
„ Single point of contact to establish each
analysis point with our power systems
engineer
ArcFlash „ Input on typical working distances
Estudio
Study ofde Riesgos
Risks
desired for each location or default to
applicable standards
„ Purchase order authorizing Siemens to
proceed

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
SUMMARY

Siemens Solutions :
Step #1: Generation/Review of unifilar complete of the plant

Step #2: The short circuit study of the energy system.

Step #3: Analysis of the current state of the protection system

Step #4: Coordination study of the protection system.

ArcFlash Step #5: Electrical Arc Flash Hazard Study.


Estudio
Study ofde Riesgos
Risks
Step #6: Identify equipment locations that exceed available
PPE ratings
Step #7: Presentation of the Program of Electrical Security
Step #8: Annual maintenance
Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim Your success is our aim
Electrical Arc Flash Hazard Study

Sample of Customer Deliverable :

Arc Energy calculations

Example Customer Summary of Incident Energy Calculations


Incident Energy in cal/cm 2 and Working Distance
Normal Normal Working Arc Flash
Marzo 18, 2004
Voltage Operation Operation Distance Boundary
Location kV J/cm2 cal/cm2 inches feet
ArcFlash 12.47 kV Main Switchgear 12,47 129,2 30,9 36,0 84,5
Estudio Unit Sub #1 480 V Main Breaker 0,48 474,4 113,4 24,0 43,9
Study ofde Riesgos
Risks
Unit Sub #1 480 V Bus 0,48 55,3 13,2 24,0 10,2
MCC A 0,48 84,1 20,1 12,0 5,6
MCC B 0,48 64,5 15,4 12,0 4,7
Panel 16 0,48 52,5 12,5 12,0 4,2

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
Electrical Arc Flash Hazard Study

Customer Benefits

„ Reduced risk of employee injury or death due to arc flash


hazards
„ Possible revisions to customer system protection to limit
equipment damage
„ Provides critical safety information for subcontractors
entering facility
ArcFlash
Estudio
Study ofde Riesgos
Risks „ Possible reduction in workers compensation and
insurance claims
„ Demonstrates company effort to satisfy OSHA and NFPA
regulations

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
A BENEFICIAL RELATION

ArcFlash
Estudio
Study ofde Riesgos
Risks

Thank you very much for your attention.


Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim
ENERGY CONTACTS in
ARGENTINA – Arc Flash

Pablo Donajger
pablo.donajger@siemens.com
0054 - 011 - 4738 7333

Pablo David
pablo.david@siemens.com
ArcFlash
Estudio
Study ofde Riesgos
Risks 0054 – 011 - 4738 7209

Industry Division
División Industria
Su éxito
Your es nuestro
success objetivo
is our aim

You might also like