Cummins YC400

Cummins KTA19-G4

Prime Power 400kW

50Hz,400V

Cummins Series Diesel Generator Set


Model YC400
Normal Power 400kW/500kVA
Standby Power 440kW/550kVA
Frequency 50Hz/1500rpm
Power Factor 0.8(lagging)
Voltage 230V/400V
Current 720/792A
Connecting type Three Phase Four Wire

Engine

Manufacturer Chongqing Cummins Co., Ltd


Model KTA19-G4
Type 4 stroke, inline
Cylinder 6L
Displacement -L 18.9L
Intake Method Turbocharged & Intercooling
Bore /Stroke mm 159/159
Compression Ratio 14.5:1
Rated Speed 1500rpm
Idling-r/min 675-775
Normal Output Power-kW 448KW(600)
Standby Output Power-kW(BHP) 504KW(675)
Mean Effective Pressure-kPa 1896
Piston Speed-m/s(ft/min) 7.9(1562)
Friction Power-kW 45

1
Fuel System Mode Cummins PT Direct Injection System
Speed Regulation Mode Electrical Speed
Engine Weight(dry-type Air cooling) kg 1855
Engine Weight(dry-type Water cooling) kg 2076
Inlet Flow- liter/sec 532(1126)
Exhaust Temperature- ℃ 538℃(1000)
Exhaust Quantity (liter/sec) 1434(3039)
Engine Heat Radiation – kw(BTU/min) 64(3654)
Cooling Water Heat Release (Kw) (BTU/min) 240(13660)
Fuel Consumption(g/kw.h)(L/h) 120
Diesel Grade 0# light diesel
Oil consumption (g/kw.h) ≤1
Oil Pressure-Low Idle Speed kPa(PSI) 138
Oil Pressure-Rated Speed kPa(PSI) 345-483
Max. Oil Temperature—℃(℉) 121(250)
Lubricating Oil Grade 15W/40
Lubricating Oil Capacity (L) 50
Cooling Fluid Capacity(L) 30

Fuel Consumption

Operating Power Fuel Consumption


Mode
BHP kW USgal/h L/h
Standby100% 755 563 35.2 133
Prime100% 680 507 31.7 120
75% 510 380 24.3 92
50% 340 254 17.0 65
25% 170 127 9.6 36
0% 0 0

2
Alternator

Manufacturer Shanghai Gexin Wuxi Faraday Elwar


Marathon
Model MP-400-4 EG315L-400N AEM354D

Output Power 400kW 400kW 400kW


Rated Current 720A 720A 720A
Rated Frequency 50Hz 50Hz 50Hz
Pressure Adjustment AVR auto AVR auto AVR auto
adjustment adjustment adjustment
Phase and Type Three-phase Three-phase Three-phase
four-wire four-wire four-wire
Protection level IP21 IP23 or IP21 IP22
Max. Altitude m 1000 1000 1000
Winding Pitch 2/3 2/3 2/3
Field System Brushless Brushless Brushless
self-excited self-excited self-excited
Insulation Grade H H H
THD <5% < 1.5% ≤3%
TIF < 50 <50 ≤50
THF <2% <2% ≤2%

Note: The above mentioned datas are standard, and some can be changed
according to client’s requirements.

Open type(standard layout)


Dimension :3370×1355×1875 mm(L×W×H)
Weight:4180 kg

Supply Scope

3
1. Standard
layout
Auto Control Sylphon
Switch panel Muffle Flange
Cabinet Bellowss
Battery
Storage Instruction Spare
Connecting
battery Manual Parts
Line

2. choice
layout
Fuel System Cycle Water Electrical System Intake System
Domestic Oil Water
Controller Intake Heater
Tank Heater
ATS Auto Switch
Fuel Heater Antifreeze
Panel
Water Oil PMG Permanent
Separator Magnetic Motor
Battery Float

3. peculiar
setup
Soundproof Box Rain Cover Movable Electric Station

Guarantee

 The product and service abide by ISO8528 & GB/T2820 standards.
 Management systems strictly abide by ISO9001 quality management system and
ISO14001 environmental management system.
 All our products must through strict delivery inspection to guarantee the superior
quality.
 High efficient assemble and production line to guarantee the delivery just-in-time.

 Professional、timely、circumspect、and ardent service.

 Favourable and complete accessories supply.


 Supply scheduled and nonscheduled technical training all the year round.
 Customer service center works all the year round 365 days/ 24 hours supplying fast
and effective service.
Control Panel Instruction

4
1. Brief Introduction
HGM6110KC series power plant auto control panel integrates the technologies of
digitization, intelligentize and network, which is used in automation and monitoring
system of single diesel generator set, achieving the purposes of starting up/ closing
down automatically, data reasoning, alarm protecting and ―three remote‖. The control
panel uses large-screen LCD, Chinese、English and Spanish can be choiced smoothly.
Simplicity of operation, reliable running.
HGM6110KC series power plant auto control panel adopts microprocessor technology,
which achieves the purposes of precision measurement of many parameters、constant
setpoint regulation and timing and threshold setting. All the data of the control panel
can be adjusted through the front panel, or can be adjusted through programmatic
interface using PC, also can be adjusted through RS485 interface using PC. The
control panel can be used widely in all kinds of automatic system for generator sets
because of its compact structure, simple connecting, and high reliability.
2. Performance and characteristics
HGM6110KC is used in single machine automation, which control the generator’s auto
starting up and closing down by remote starting up signal.
The main characteristics as follows:
 The dimension of LCD is 128x64, with backlight, three languages (Chinese、English、
Spanish), operation by pressing the button gently.
 Equipped with RS485 communication interface, achieve ―three remote‖ by using
MODBUS.
 Be fit for the power source of three phase four wire、single phase two wire、two phase
three wire, 50/60HZ.
 Collect and display parameters of utility power/ generating electricity three-phase
voltage、three-phase current、frequency and power.

Utility Power
Line voltage Uab,Ubc,Uca
Phase V Ua,Ub,Uc
frequency Hz

5
Generating Electricity
Line V Uab,Ubc,Uca
Phase V Ua,Ub,Uc
Frequency Hz

Load
Current IA,IB,IC
Active power kW
Reactive power kVar
Applied power kVA
Power factor Cos
Accumulated electric energy kWh

 Utility power has functions of overvoltage、undervoltage and open-phase. Generating


electricity has functions of overvoltage、undervoltage、overfrequency、underfrequency
and overcurrent.
 Collect all the parameters of engine precisely.
 Both display WT °C/ °F temperature.
 Both display engine oil pressure OP KPA/PSI/BAR.
 Fuel oil level FL unit: %
 Rotate speed SPD unit: RPM
 Battery voltage VB unit: V
 Charger voltage VD unit: V
 Timer HC can be accumulated to 999999 hours.
 Starting up times can be accumulated to 999999.
 Control protection: achieve the functions of auto starting up/ closing down、switch
on/off (ATS switch) and thorough fault display.
 With the functions of closing down when utility power is available, idling control,
prehest control and raising/ down speed control, and all relay output.
 Parameters setup function: Allowing to change the parameters, and at the same time
remember in inner FLASH storage and it’ll be not lost when the power is cut. All the
parameters of the control panel can be adjusted through the front panel or can be
adjusted through programmatic interface using PC (use SG72 adapter), also can be
adjusted through RS485 interface using PC.
 Various temperature、pressure、oil level sensor can be used directly, and can setup
parameters self.
 Various successful starting up condition can be choiced (speed sensor、oil pressure、
generate electricity).
 Wide power source scope (8-35)VDC, and can fit different starting battery pressure.
 All the parameters adopt digital adjustment, get rid of imitate adjustment of normal
potentiometer, and improves the reliability and stability of the whole set.
 Modular construction design, antiflaming ABS shell, umbilical binding post,
embedded install type, compact structure, easy installation.

Note: The photo and datas are just for reference, if changed, will not prior notice.