INSTALLATIONS

5000 AND 5600 ANALOG GAS TRANSMITTERS

SERIES 5000 SERIES 5600

FREEDOM® SERIES
5000 AND 5600 ANALOG GAS TRANSMITTERS

ELECTRICAL CONNECTIONS - SERIES 5600

ELECTRICAL CONNECTIONS - SERIES 5000

Monroe Corporate Center • P.O. Box 569 • Monroe, NC 28111


Telephone: 800.247.7257 • Facsimile: 704.291.8330
www.scotthealthsafety.com • sh-sale@tycoint.com
H/S 6715 4/08 ISO 9001 Registered. All rights reserved.
FREEDOM ™ SERIES 5000
MAKE INSTALLATION AND EVERYDAY OPERATION EASY

SENSOR SELF TEST


Any electrochemical sensor can
The Freedom series transmitters offer full-featured 4-20mA, loop powered Easy Installation, Operation and Maintenance
transmitters designed to reliably detect oxygen, hydrogen, and any of a The unique electrical design of the Freedom transmitter and sensor virtually potentially fail without warning.
number of other toxic gases. Its universal electronics and flexible, user-friendly eliminate false alarms due to RFI/EMI sources. The transmitter can be mounted The Sensor Self Test (SST) option
features drive down gas detection costs for almost any facility. directly to rigid conduit and is available with several optional adapters
including wall/surface mount and a special “L” shaped bracket to allow reduces overall maintenance
mounting on top of flat surfaces such as gas cabinets. Freedom series costs by providing users with
Advanced Gas Sensors and Universal Electronics transmitters are also available with quick connect 1/4 turn sample draw and
The Freedom series advanced GasPlus sensor technology combines with (flat or round) duct mount adapters. The sensor can be remoted from the a means to conduct an automatic
the Freedom’s universal electronics to simplify use and minimize transmitter up to 50 feet with or without conduit. A special option allows functional test of the sensor in
maintenance requirements of your gas detection system. Every Scott separation of three feet, perfect for mounting the sensor near ground level
instruments “smart” sensor provides data such as gas type, range, and while keeping the display at eye level. This option includes flexible conduit. wind speeds up to 22 mph.
calibration data to the universal electronics for automatic transmitter A built-in, programmable gas
configuration. A built-in lithium battery keeps the sensor “hot,” which Operating our Freedom transmitters is simple and intuitive. After start-up, the
eliminates the need for sensor warm-up time. On board electronics enables transmitter automatically configures to the sensors parameters. The “missing generator exposes the sensor
users to maintain and calibrate the sensor remote from the instrument. A sensor indicator” alerts operators that the sensor is either missing or the sensor to a “test gas” at user determined
patented elastomeric connector eliminates pin alignments and makes transmitter connection has been broken.
sensor replacement quick and easy. intervals and alerts personnel if
Calibration is non-intrusive, performed by touching a magnet to the the unit fails to respond by pulsing
“Z” (zero) and “S” (span) markings on the enclosure. A programmable
local inhibit feature and standard local display allows true one-man the Fault output for a 10 second
calibration. interval once a minute. The SST

Series 5600 transmitters also offer an optional integral relay board continues to re-test the sensor
providing fail, low, and high 5A SPDT relay contacts. A remote reset until a successful functional test
terminal is provided and the high alarm can be configured as
Intrinsically safe, the Freedom 5000 is housed in acknowledgeable. Relays can be configured to activate on either rising has been completed.
a durable, chemical resistant, stainless steel body. or falling gas concentration.
Only available for use with certain
gas sensors. SST feature not
Explosion-proof Freedom 5600 available with flowcell,
with Sensor Self Test (SST) option.
humi-shield, or duct mount
configurations.
FREEDOM ™ SERIES 5000
MAKE INSTALLATION AND EVERYDAY OPERATION EASY

SENSOR SELF TEST


Any electrochemical sensor can
The Freedom series transmitters offer full-featured 4-20mA, loop powered Easy Installation, Operation and Maintenance
transmitters designed to reliably detect oxygen, hydrogen, and any of a The unique electrical design of the Freedom transmitter and sensor virtually potentially fail without warning.
number of other toxic gases. Its universal electronics and flexible, user-friendly eliminate false alarms due to RFI/EMI sources. The transmitter can be mounted The Sensor Self Test (SST) option
features drive down gas detection costs for almost any facility. directly to rigid conduit and is available with several optional adapters
including wall/surface mount and a special “L” shaped bracket to allow reduces overall maintenance
mounting on top of flat surfaces such as gas cabinets. Freedom series costs by providing users with
Advanced Gas Sensors and Universal Electronics transmitters are also available with quick connect 1/4 turn sample draw and
The Freedom series advanced GasPlus sensor technology combines with (flat or round) duct mount adapters. The sensor can be remoted from the a means to conduct an automatic
the Freedom’s universal electronics to simplify use and minimize transmitter up to 50 feet with or without conduit. A special option allows functional test of the sensor in
maintenance requirements of your gas detection system. Every Scott separation of three feet, perfect for mounting the sensor near ground level
instruments “smart” sensor provides data such as gas type, range, and while keeping the display at eye level. This option includes flexible conduit. wind speeds up to 22 mph.
calibration data to the universal electronics for automatic transmitter A built-in, programmable gas
configuration. A built-in lithium battery keeps the sensor “hot,” which Operating our Freedom transmitters is simple and intuitive. After start-up, the
eliminates the need for sensor warm-up time. On board electronics enables transmitter automatically configures to the sensors parameters. The “missing generator exposes the sensor
users to maintain and calibrate the sensor remote from the instrument. A sensor indicator” alerts operators that the sensor is either missing or the sensor to a “test gas” at user determined
patented elastomeric connector eliminates pin alignments and makes transmitter connection has been broken.
sensor replacement quick and easy. intervals and alerts personnel if
Calibration is non-intrusive, performed by touching a magnet to the the unit fails to respond by pulsing
“Z” (zero) and “S” (span) markings on the enclosure. A programmable
local inhibit feature and standard local display allows true one-man the Fault output for a 10 second
calibration. interval once a minute. The SST

Series 5600 transmitters also offer an optional integral relay board continues to re-test the sensor
providing fail, low, and high 5A SPDT relay contacts. A remote reset until a successful functional test
terminal is provided and the high alarm can be configured as
Intrinsically safe, the Freedom 5000 is housed in acknowledgeable. Relays can be configured to activate on either rising has been completed.
a durable, chemical resistant, stainless steel body. or falling gas concentration.
Only available for use with certain
gas sensors. SST feature not
Explosion-proof Freedom 5600 available with flowcell,
with Sensor Self Test (SST) option.
humi-shield, or duct mount
configurations.
FREEDOM™ SERIES ADVANTAGES
ADVANCED FEATURES AND SMART SENSOR TECHNOLOGY

SCOTT SMART
SENSOR TECHNOLOGY
Standard Features of the Freedom Series We Make Sensors that Make a Difference.
Freedom from stocking additional electronics. Universal transmitter Unlike most gas detection companies, Scott develops and manufactures the Our advanced electrochemical, high
electronics for all gas models. gas sensors used in its detection instruments. Our team of research and performance Rock Solid sensors for the
development scientists work every day to advance sensor technologies and
Freedom from intrusive operation/calibration. A simple magnetic Freedom Series 5000 are available to
improve manufacturing
interface and local inhibit eliminates special tools or expensive IR Speed Of Response & Recovery Time
techniques. The result — detect most toxic gases.
Typical Electrochemical Sensor ROCK SOLID® Sensor
remote controls. over 40 reliable, stable, and • Ammonia
Freedom from bump testing Sensor Self Test option automatically gas specific sensors including • Arsine

OUTPUT

OUTPUT
challenges sensor with real gas. our Rock Solid® series of high
• Boron Trichloride
Freedom from sensor pins or wires. Patented elastomeric connector performance sensors.
Gas
Exposure
Gas
Exposure
• Boron Trifluoride
makes for quick easy installation. 1 2

High Performance • Bromine


Freedom from field maintenance and calibration. Smart sensor technology TIME TIME
Gas Sensors
permits sensor removal for remote calibration. Let Scott instruments • Carbon Monoxide
calibrate your sensors with the CALPLUS sensor calibration program. Zero Stability vs Temperature Rock Solid high performance • Chlorine
Typical Electrochemical Sensor ROCK SOLID® Sensor
sensors use our proprietary
Freedom from zero drift & interfering gases. Rock Solid Sensor Technology
® • Chlorine Dioxide
technology that significantly
offers super stability and selectivity. enhances sensor performance. • Diborane

OUTPUT

OUTPUT
Freedom from sensor failure without warning. Built-in calibration factor Rock Solid sensors can detect • Fluorine
notifies user of remaining sensor life. gas concentrations lower than • Germane
Freedom from RFI/EMI induced alarms. Design concept eliminates any other electrochemical
-40º -20º -0º 20º 40º -40º -20º -0º 20º 40º • Hydrogen
interference through electronic design versus shielding. TEMPERATURE TEMPERATURE gas sensor.
• Hydrogen Bromide
Freedom from sensor warm-up times. An internal battery keeps the
Rock Solid sensors provide: • Hydrogen Chloride
sensor “warm” for immediate start up.
• Highest stability • Hydrogen Cyanide
Freedom from corrosion. All plastic (5000) and stainless steel construction
• Lowest zero drift • Hydrogen Fluoride
with conformal coated internal circuitry.
• Greatest sensitivity
• Greatest specificity to the target gas • Hydrogen Sulfide
• Fastest speed of response and recovery time • Methanol
• Methyl Mercaptan
• Methyl Iodide
• Nitric Oxide (NO)
• Nitrogen Dioxide
• Oxygen
• Ozone
• Phosgene
• Phosphine
• Silane
• Silicon Tetrafluoride
Flexible Conduit Remote Sensor Remote Enclosure with SST Option
• Sulfur Dioxide
• TEOS
• Tungsten Hexafluoride
FREEDOM™ SERIES ADVANTAGES
ADVANCED FEATURES AND SMART SENSOR TECHNOLOGY

SCOTT SMART
SENSOR TECHNOLOGY
Standard Features of the Freedom Series We Make Sensors that Make a Difference.
Freedom from stocking additional electronics. Universal transmitter Unlike most gas detection companies, Scott develops and manufactures the Our advanced electrochemical, high
electronics for all gas models. gas sensors used in its detection instruments. Our team of research and performance Rock Solid sensors for the
development scientists work every day to advance sensor technologies and
Freedom from intrusive operation/calibration. A simple magnetic Freedom Series 5000 are available to
improve manufacturing
interface and local inhibit eliminates special tools or expensive IR Speed Of Response & Recovery Time
techniques. The result — detect most toxic gases.
Typical Electrochemical Sensor ROCK SOLID® Sensor
remote controls. over 40 reliable, stable, and • Ammonia
Freedom from bump testing Sensor Self Test option automatically gas specific sensors including • Arsine

OUTPUT

OUTPUT
challenges sensor with real gas. our Rock Solid® series of high
• Boron Trichloride
Freedom from sensor pins or wires. Patented elastomeric connector performance sensors.
Gas
Exposure
Gas
Exposure
• Boron Trifluoride
makes for quick easy installation. 1 2

High Performance • Bromine


Freedom from field maintenance and calibration. Smart sensor technology TIME TIME
Gas Sensors
permits sensor removal for remote calibration. Let Scott instruments • Carbon Monoxide
calibrate your sensors with the CALPLUS sensor calibration program. Zero Stability vs Temperature Rock Solid high performance • Chlorine
Typical Electrochemical Sensor ROCK SOLID® Sensor
sensors use our proprietary
Freedom from zero drift & interfering gases. Rock Solid Sensor Technology
® • Chlorine Dioxide
technology that significantly
offers super stability and selectivity. enhances sensor performance. • Diborane

OUTPUT

OUTPUT
Freedom from sensor failure without warning. Built-in calibration factor Rock Solid sensors can detect • Fluorine
notifies user of remaining sensor life. gas concentrations lower than • Germane
Freedom from RFI/EMI induced alarms. Design concept eliminates any other electrochemical
-40º -20º -0º 20º 40º -40º -20º -0º 20º 40º • Hydrogen
interference through electronic design versus shielding. TEMPERATURE TEMPERATURE gas sensor.
• Hydrogen Bromide
Freedom from sensor warm-up times. An internal battery keeps the
Rock Solid sensors provide: • Hydrogen Chloride
sensor “warm” for immediate start up.
• Highest stability • Hydrogen Cyanide
Freedom from corrosion. All plastic (5000) and stainless steel construction
• Lowest zero drift • Hydrogen Fluoride
with conformal coated internal circuitry.
• Greatest sensitivity
• Greatest specificity to the target gas • Hydrogen Sulfide
• Fastest speed of response and recovery time • Methanol
• Methyl Mercaptan
• Methyl Iodide
• Nitric Oxide (NO)
• Nitrogen Dioxide
• Oxygen
• Ozone
• Phosgene
• Phosphine
• Silane
• Silicon Tetrafluoride
Flexible Conduit Remote Sensor Remote Enclosure with SST Option
• Sulfur Dioxide
• TEOS
• Tungsten Hexafluoride
FREEDOM 5000 SPECIFICATIONS
Transmitter Enclosure . . .NEMA-4X Noryl plastic with
. . . . . . . . . . . . . . . . . . . . . . . .stainless steel screws and hinge

FREEDOM ™ SERIES 5000 . . . . . . . . . . . . . . . . . . . . . .2 each ½ in FNPT fittings


Weight . . . . . . . . . . . . . . . . . .1.0 lbs (0.45kg) without accessories
Approvals . . . . . . . . . . . . .CSA Ex ia IIC T4, AEx ia IIC T4
. . . . . . . . . . . . . . . . . . . . . .2002 1280868x Zone 0, Class 1,
5000 AND 5600 TRANSMITTERS GAS AND SENSOR LISTS . . . . . . . . . . . . . . . . . . . . . .Division 1, Groups A, B, C, and D
. . . . . . . . . . . . . . . . . . . . . .(with conforming I.S. barrier)
. . . . . . . . . . . . . . . . . . . . . .Class 1, Division 2, Groups A, B,
. . . . . . . . . . . . . . . . . . . . . .C, and D (without the need for
. . . . . . . . . . . . . . . . . . . . . . . . .an I.S. barrier)
. . . . . . . . . . . . . . . . . . . . . . . . .ATEX Ex ia IIc T4
FREEDOM 5000 AND 5600 GAS LIST FREEDOM 5000 SENSOR CONNECTIONS AVAILABLE FREEDOM 5600 SENSOR CONNECTIONS AVAILABLE . . . . . . . . . . . . . . . . . . . . . .LCIE 03 ATEX 6426 X
No sensor with standard endcap Integral Sensor with Transmitter Integral Sensor with Transmitter
Separated Sensor with 3 ft of cable (cables up to 50 ft are available) Integral Sensor with Transmitter and Sensor Self Test
No sensor with Rock Solid® endcap Integral Sensor with Transmitter and Sensor Self Test (SST not Transmitter with Remote Sensor/Junction Box FREEDOM 5600 SPECIFICATIONS
Ammonia (NH3) (0-50, 100, 150, 250, 500) PPM available with remote sensor, flowcell or duct mount configurations) (4 ft Cable Standard/Max. Length 50 ft) Transmitter Enclosure . . .NEMA 4X, 7 Copper-free cast
Arsine (AsH3) Rock Solid (0-500 PPB, 3, 10 PPM) Remote Sensor Option for Rigid Conduit Installations: Separated Transmitter with Remote Sensor, SST option and Junction Box . . . . . . . . . . . . . . . . . . . . . .aluminum, baked epoxy finish 2
Arsine (AsH3) (0-1000 PPB, 3, 10) PPM Sensor with 3 ft of cable and customer supplied conduit (4 ft Cable Standard/Max. Length 50 ft) . . . . . . . . . . . . . . . . . . . . . .each ¾ in FNPT fittings
Boron Trichloride (BCl3) Rock Solid (0-1, 3, 5) PPM (cables up to 50 ft are available) Transmitter with Integral Sensor and Condensing Humidity Sensor Housing Weight . . . . . . . . . . . . . . .3.0 lbs (1.3kg)
Flexible Conduit Option: Separated Sensor with 3 ft of cable and and Humi-Shield End-Cap (4 ft Cable - Standard/Max. Length 50 ft)
Boron Trifluoride (BF3) Rock Solid (0-1, 3, 5) PPM flexible conduit supplied (flexible conduit is PVC jacketed metal, Transmitter with Remote Sensor, Condensing Humidity Sensor Housing and Approvals . . . . . . . . . . . . .CSA and ATEX Class 1 Division 2
Bromine (Br2) Rock Solid (0-1, 3, 5, 10, 15, 25, 30) PPM sunlight resistant, liquid tight, ¾ in conduit with stainless steel Humi-Shield End-Cap, and Junction Box (4 ft Cable Standard/Max. Length 50 ft) . . . . . . . . . . . . . . . . . . . . . .Groups A, B, C, and D
Bromine (Br2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100) PPM fittings supplied). Transmitter with Remote Sensor, (No Junction Box) (Max. length 50 ft) . . . . . . . . . . . . . . . . . . . . . .ATEX EEx nL IIc T6,
Carbon Monoxide (0-50, 100, 150, 200, 250, 300, 500, 1000) PPM . . . . . . . . . . . . . . . . . . . . . .LCIE 03 ATEX 6437 X
Chlorine (Cl2) Rock Solid (0-1, 3, 5, 10, 15, 25, 30) PPM FREEDOM 5000 ADAPTERS AVAILABLE FREEDOM 5600 ADAPTERS AVAILABLE Relay Options . . . . . . . . .Requires separate additional 24
Chlorine (Cl2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100, 200) PPM . . . . . . . . . . . . . . . . . . . . . .VDC power supply. (3) SPDT 5A
Rain Shield Quarter Turn Rain Shield (typical) . . . . . . . . . . . . . . . . . . . . . .noninductive Fault, Low, High.
Chlorine Dioxide Rock Solid (0-1, 3, 5, 10, 15) PPM Flat Duct Adapter Combined Rain Shield/Cal Adapter with Stainless Steel End Cap
Chlorine Dioxide (ClO2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100) PPM . . . . . . . . . . . . . . . . . . . . . .Configurable latching/non-
Round Duct Adapter (6 to 8 in diameter typical) (for remote sensor calibration applications) . . . . . . . . . . . . . . . . . . . . . .latching, failsafe/non-failsafe,
Dichlorosilane (SiH2Cl2) - Order Rock Solid HCl sensor Flow Cell Quarter Flowcell . . . . . . . . . . . . . . . . . . . . . . . .rising/falling. A2 can be configured
Diborane (B2H6) (0-1000 PPB, 2, 10) PPM Flat Duct Adapter (for Transmitter with Remote Sensor Only) . . . . . . . . . . . . . . . . . . . . . .as acknowledgeable.
Diborane (B2H6) Rock Solid (0-1000, 500 PPB, 2, 3, 5, 10) PPM FREEDOM 5000 SENSOR SELF TEST OPTIONS Round Duct Adapter (for Transmitter with Remote Sensor Only)
Fluorine (F2) Rock Solid (0-1, 3, 5, 10, 15, 20, 30) PPM Type A (Integral Sensor with Transmitter and Sensor Self Test must
Fluorine (F2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100) PPM be ordered) FREEDOM 5600 SENSOR SELF TEST OPTIONS
COMMON SPECIFICATIONS
Germane (GeH4) (0-1000 PPB, 3, 10) PPM Type A used with Rock Solid BCL3, BF3, Cl2, ClO2, HBr, HCl, HF, O3, Type A (for SST Option only) Type A used with Rock Solid BCL3, BF3,
SO2, SiF4,WF6 sensors and conventional Cl2 sensor. Cl2, ClO2, HBr, HCl, HF, O3, SO2, SiF4, WF6 sensors and conventional Self-Diagnostics . . . . . . . .Weak sensor indication;
Hydrogen (H2) (0-1%, 4%, 5%, 10%) . . . . . . . . . . . . . . . . . . . . . .Electronic faults; Missing sensor;
Hydrogen Bromide Rock Solid (0-1, 3, 5, 10, 15, 20, 25, 30) PPM SST not available with remote sensor, flow Cell, humi-shield Cl2 sensor. SST not available with remote sensor, flowcell, humi-shield
or duct mount configurations or duct mount configurations . . . . . . . . . . . . . . . . . . . . . .Sensor configuration (range and
Hydrogen Chloride Rock Solid (0-1, 3, 5, 10, 15, 2, 0, 25, 30) PPM Type B used with H2S sensor Type B - (for SST Option only) used with H2S sensor . . . . . . . . . . . . . . . . . . . . . .type); and SST failure Output
Hydrogen Chloride (HCl) (0-10, 25, 50, 100) PPM . . . . . . . . . . . . . . . . . . . . . .drops to 3.1mA in above failures
Hydrogen Cyanide (HCN) Rock Solid (0-1, 2, 3, 5, 10) PPM . . . . . . . . . . . . . . . . . . . . . .except for weak sensor indication
FREEDOM 5000 TRANSMITTER MOUNTING ADAPTER FREEDOM 5600 DISPLAY/RELAY OPTIONS . . . . . . . . . . . . . . . . . . . . . .(output unaffected)
Hydrogen Cyanide (HCN) (0-10, 25, 30, 50, 100) PPM
Wall/Surface Mount Local Display with Magnetic Switches
Hydrogen Fluoride (HF) Rock Solid (0-1, 3, 5, 10, 15, 25, 30) PPM Repeatability . . . . . . . . . .± 2% FS
"L" Bracket used for mounting on horizontal surfaces Blind (uses 096-2741 Hand Held Plug-In Display Order Separately)
Hydrogen Fluoride (HF) (0-10, 15, 25, 50, 100) PPM Local Display with Push Button Switches (requires cover to be Linearity . . . . . . . . . . . . .± 2% FS
Hydrogen Sulfide (H2S) (0-10, 25, 50, 100, 200) PPM removed for use) Output . . . . . . . . . . . . . . . . . .4-20mA
Methanol (CH3OH) (0-500) PPM Local Display with Magnetic Switches and Relay Option* Max Loop Load . . . . . . . . . .2-Wire; 700 ohms at 24 VDC
Methyl Mercaptan (0-5 with H2S filter) PPM Blind with Relay Option (uses 096-2741 Order Separately)* . . . . . . . . . . . . . . . . . . . . . . . . .(22 mA based)
Methyl Mercaptan (0-3 with filter) PPM Local Display with Pushbutton Switches and Relay Option* Power . . . . . . . . . . . . . . . .10 to 28 VDC 2-wire loop power,
(requires cover to be removed for use) . . . . . . . . . . . . . . . . . . . . . .0.5 Watts at 24 VDC
Methyl Iodide (CH3I) (0-25) PPM
Separated Sensor . . . . . . .Up to 50 ft (15.25m)
Methylene Chloride (CH2Cl2) (0-200) PPM Display . . . . . . . . . . . . . . .3.5 digit LCD; 0 to 100%
Nitric Oxide (NO) (0-25, 50, 100, 500) PPM *A1|A2| Fail Relays are Form C Rated 5 A SPDT at 30 VDC - 270 VAC . . . . . . . . . . . . . . . . . . . . . .concentration bargraph; SST
Nitrogen Dioxide (NO2) (0-10, 25, 50, 100, 250) PPM . . . . . . . . . . . . . . . . . . . . . .in Operation Indication (SST);
Nitrogen Trifluoride (NF3) (0-10) PPM . . . . . . . . . . . . . . . . . . . . . . . . .Inhibit Indication (IHB);
Oxygen (O2) (0-10%, 5%) . . . . . . . . . . . . . . . . . . . . . .Overrange Indication (OR);
Ozone (O3) (0-1, 2, 3, 5, 10, 15, 25, 30, 50, 100) PPM . . . . . . . . . . . . . . . . . . . . . .Low Cal Factor Indication –
. . . . . . . . . . . . . . . . . . . . . .below 150 (SEN)
Ozone Rock Solid (O3) (0-1, 3, 5, 10, 15, 20, 25, 30) PPM
Local Inhibit . . . . . . . . . .Programmable: 3.0 to 20mA
Phosgene (0-1) PPM Temperature . . . . . . . . . .Sensor: See Capabilities Chart
Phosgene with HCN filter (0-2) PPM . . . . . . . . . . . . . . . . . . . . . .Transmitter: -40° to 140°F (-40° to
Phosphine (PH3) Rock Solid (0-500 PPB 1, 3, 5 PPM) . . . . . . . . . . . . . . . . . . . . . . . .60°C) LCD -40° to 140°F (-40° to
Phosphine (PH3) (0-1000 PPB, 3,10 PPM) . . . . . . . . . . . . . . . . . . . . . . . .60°C)* Note: at temperatures below
Silane (SiH4) (0-1000 PPB, 0-10 PPM) . . . . . . . . . . . . . . . . . . . . . . . . .22°F display may not be visible
Silicon Tetrafluoride (SiF4) Rock Solid (0-1, 3, 5) PPM
Humidity . . . . . . . . . . . . .Up to 99% RH, non-condensing
Sulfur Dioxide (SO2) Rock Solid (0-1, 3, 5, 10, 15, 25, 50, 30) PPM
(up to 100% R.H. with optional
Sulfur Dioxide (SO2) (0-10, 15, 25, 50, 100, 500) PPM humi-shield) Not recommended
TEOS (Si(O2H5)4 ) (0-50) PPM for continuous extreme high/low
Tungsten Hexafluoride (WF6) Rock Solid (0-1, 3, 5) PPM humidity applications

Warranties . . . . . . . . . . . .Transmitter: 1 Year


. . . . . . . . . . . . . . . . . . . . . .Sensor: 1 Year (except phosgen
. . . . . . . . . . . . . . . . . . . . . .sensor which is 7 months)
FREEDOM 5000 SPECIFICATIONS
Transmitter Enclosure . . .NEMA-4X Noryl plastic with
. . . . . . . . . . . . . . . . . . . . . . . .stainless steel screws and hinge

FREEDOM ™ SERIES 5000 . . . . . . . . . . . . . . . . . . . . . .2 each ½ in FNPT fittings


Weight . . . . . . . . . . . . . . . . . .1.0 lbs (0.45kg) without accessories
Approvals . . . . . . . . . . . . .CSA Ex ia IIC T4, AEx ia IIC T4
. . . . . . . . . . . . . . . . . . . . . .2002 1280868x Zone 0, Class 1,
5000 AND 5600 TRANSMITTERS GAS AND SENSOR LISTS . . . . . . . . . . . . . . . . . . . . . .Division 1, Groups A, B, C, and D
. . . . . . . . . . . . . . . . . . . . . .(with conforming I.S. barrier)
. . . . . . . . . . . . . . . . . . . . . .Class 1, Division 2, Groups A, B,
. . . . . . . . . . . . . . . . . . . . . .C, and D (without the need for
. . . . . . . . . . . . . . . . . . . . . . . . .an I.S. barrier)
. . . . . . . . . . . . . . . . . . . . . . . . .ATEX Ex ia IIc T4
FREEDOM 5000 AND 5600 GAS LIST FREEDOM 5000 SENSOR CONNECTIONS AVAILABLE FREEDOM 5600 SENSOR CONNECTIONS AVAILABLE . . . . . . . . . . . . . . . . . . . . . .LCIE 03 ATEX 6426 X
No sensor with standard endcap Integral Sensor with Transmitter Integral Sensor with Transmitter
Separated Sensor with 3 ft of cable (cables up to 50 ft are available) Integral Sensor with Transmitter and Sensor Self Test
No sensor with Rock Solid® endcap Integral Sensor with Transmitter and Sensor Self Test (SST not Transmitter with Remote Sensor/Junction Box FREEDOM 5600 SPECIFICATIONS
Ammonia (NH3) (0-50, 100, 150, 250, 500) PPM available with remote sensor, flowcell or duct mount configurations) (4 ft Cable Standard/Max. Length 50 ft) Transmitter Enclosure . . .NEMA 4X, 7 Copper-free cast
Arsine (AsH3) Rock Solid (0-500 PPB, 3, 10 PPM) Remote Sensor Option for Rigid Conduit Installations: Separated Transmitter with Remote Sensor, SST option and Junction Box . . . . . . . . . . . . . . . . . . . . . .aluminum, baked epoxy finish 2
Arsine (AsH3) (0-1000 PPB, 3, 10) PPM Sensor with 3 ft of cable and customer supplied conduit (4 ft Cable Standard/Max. Length 50 ft) . . . . . . . . . . . . . . . . . . . . . .each ¾ in FNPT fittings
Boron Trichloride (BCl3) Rock Solid (0-1, 3, 5) PPM (cables up to 50 ft are available) Transmitter with Integral Sensor and Condensing Humidity Sensor Housing Weight . . . . . . . . . . . . . . .3.0 lbs (1.3kg)
Flexible Conduit Option: Separated Sensor with 3 ft of cable and and Humi-Shield End-Cap (4 ft Cable - Standard/Max. Length 50 ft)
Boron Trifluoride (BF3) Rock Solid (0-1, 3, 5) PPM flexible conduit supplied (flexible conduit is PVC jacketed metal, Transmitter with Remote Sensor, Condensing Humidity Sensor Housing and Approvals . . . . . . . . . . . . .CSA and ATEX Class 1 Division 2
Bromine (Br2) Rock Solid (0-1, 3, 5, 10, 15, 25, 30) PPM sunlight resistant, liquid tight, ¾ in conduit with stainless steel Humi-Shield End-Cap, and Junction Box (4 ft Cable Standard/Max. Length 50 ft) . . . . . . . . . . . . . . . . . . . . . .Groups A, B, C, and D
Bromine (Br2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100) PPM fittings supplied). Transmitter with Remote Sensor, (No Junction Box) (Max. length 50 ft) . . . . . . . . . . . . . . . . . . . . . .ATEX EEx nL IIc T6,
Carbon Monoxide (0-50, 100, 150, 200, 250, 300, 500, 1000) PPM . . . . . . . . . . . . . . . . . . . . . .LCIE 03 ATEX 6437 X
Chlorine (Cl2) Rock Solid (0-1, 3, 5, 10, 15, 25, 30) PPM FREEDOM 5000 ADAPTERS AVAILABLE FREEDOM 5600 ADAPTERS AVAILABLE Relay Options . . . . . . . . .Requires separate additional 24
Chlorine (Cl2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100, 200) PPM . . . . . . . . . . . . . . . . . . . . . .VDC power supply. (3) SPDT 5A
Rain Shield Quarter Turn Rain Shield (typical) . . . . . . . . . . . . . . . . . . . . . .noninductive Fault, Low, High.
Chlorine Dioxide Rock Solid (0-1, 3, 5, 10, 15) PPM Flat Duct Adapter Combined Rain Shield/Cal Adapter with Stainless Steel End Cap
Chlorine Dioxide (ClO2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100) PPM . . . . . . . . . . . . . . . . . . . . . .Configurable latching/non-
Round Duct Adapter (6 to 8 in diameter typical) (for remote sensor calibration applications) . . . . . . . . . . . . . . . . . . . . . .latching, failsafe/non-failsafe,
Dichlorosilane (SiH2Cl2) - Order Rock Solid HCl sensor Flow Cell Quarter Flowcell . . . . . . . . . . . . . . . . . . . . . . . .rising/falling. A2 can be configured
Diborane (B2H6) (0-1000 PPB, 2, 10) PPM Flat Duct Adapter (for Transmitter with Remote Sensor Only) . . . . . . . . . . . . . . . . . . . . . .as acknowledgeable.
Diborane (B2H6) Rock Solid (0-1000, 500 PPB, 2, 3, 5, 10) PPM FREEDOM 5000 SENSOR SELF TEST OPTIONS Round Duct Adapter (for Transmitter with Remote Sensor Only)
Fluorine (F2) Rock Solid (0-1, 3, 5, 10, 15, 20, 30) PPM Type A (Integral Sensor with Transmitter and Sensor Self Test must
Fluorine (F2) (0-1, 3, 5, 10, 15, 25, 30, 50, 100) PPM be ordered) FREEDOM 5600 SENSOR SELF TEST OPTIONS
COMMON SPECIFICATIONS
Germane (GeH4) (0-1000 PPB, 3, 10) PPM Type A used with Rock Solid BCL3, BF3, Cl2, ClO2, HBr, HCl, HF, O3, Type A (for SST Option only) Type A used with Rock Solid BCL3, BF3,
SO2, SiF4,WF6 sensors and conventional Cl2 sensor. Cl2, ClO2, HBr, HCl, HF, O3, SO2, SiF4, WF6 sensors and conventional Self-Diagnostics . . . . . . . .Weak sensor indication;
Hydrogen (H2) (0-1%, 4%, 5%, 10%) . . . . . . . . . . . . . . . . . . . . . .Electronic faults; Missing sensor;
Hydrogen Bromide Rock Solid (0-1, 3, 5, 10, 15, 20, 25, 30) PPM SST not available with remote sensor, flow Cell, humi-shield Cl2 sensor. SST not available with remote sensor, flowcell, humi-shield
or duct mount configurations or duct mount configurations . . . . . . . . . . . . . . . . . . . . . .Sensor configuration (range and
Hydrogen Chloride Rock Solid (0-1, 3, 5, 10, 15, 2, 0, 25, 30) PPM Type B used with H2S sensor Type B - (for SST Option only) used with H2S sensor . . . . . . . . . . . . . . . . . . . . . .type); and SST failure Output
Hydrogen Chloride (HCl) (0-10, 25, 50, 100) PPM . . . . . . . . . . . . . . . . . . . . . .drops to 3.1mA in above failures
Hydrogen Cyanide (HCN) Rock Solid (0-1, 2, 3, 5, 10) PPM . . . . . . . . . . . . . . . . . . . . . .except for weak sensor indication
FREEDOM 5000 TRANSMITTER MOUNTING ADAPTER FREEDOM 5600 DISPLAY/RELAY OPTIONS . . . . . . . . . . . . . . . . . . . . . .(output unaffected)
Hydrogen Cyanide (HCN) (0-10, 25, 30, 50, 100) PPM
Wall/Surface Mount Local Display with Magnetic Switches
Hydrogen Fluoride (HF) Rock Solid (0-1, 3, 5, 10, 15, 25, 30) PPM Repeatability . . . . . . . . . .± 2% FS
"L" Bracket used for mounting on horizontal surfaces Blind (uses 096-2741 Hand Held Plug-In Display Order Separately)
Hydrogen Fluoride (HF) (0-10, 15, 25, 50, 100) PPM Local Display with Push Button Switches (requires cover to be Linearity . . . . . . . . . . . . .± 2% FS
Hydrogen Sulfide (H2S) (0-10, 25, 50, 100, 200) PPM removed for use) Output . . . . . . . . . . . . . . . . . .4-20mA
Methanol (CH3OH) (0-500) PPM Local Display with Magnetic Switches and Relay Option* Max Loop Load . . . . . . . . . .2-Wire; 700 ohms at 24 VDC
Methyl Mercaptan (0-5 with H2S filter) PPM Blind with Relay Option (uses 096-2741 Order Separately)* . . . . . . . . . . . . . . . . . . . . . . . . .(22 mA based)
Methyl Mercaptan (0-3 with filter) PPM Local Display with Pushbutton Switches and Relay Option* Power . . . . . . . . . . . . . . . .10 to 28 VDC 2-wire loop power,
(requires cover to be removed for use) . . . . . . . . . . . . . . . . . . . . . .0.5 Watts at 24 VDC
Methyl Iodide (CH3I) (0-25) PPM
Separated Sensor . . . . . . .Up to 50 ft (15.25m)
Methylene Chloride (CH2Cl2) (0-200) PPM Display . . . . . . . . . . . . . . .3.5 digit LCD; 0 to 100%
Nitric Oxide (NO) (0-25, 50, 100, 500) PPM *A1|A2| Fail Relays are Form C Rated 5 A SPDT at 30 VDC - 270 VAC . . . . . . . . . . . . . . . . . . . . . .concentration bargraph; SST
Nitrogen Dioxide (NO2) (0-10, 25, 50, 100, 250) PPM . . . . . . . . . . . . . . . . . . . . . .in Operation Indication (SST);
Nitrogen Trifluoride (NF3) (0-10) PPM . . . . . . . . . . . . . . . . . . . . . . . . .Inhibit Indication (IHB);
Oxygen (O2) (0-10%, 5%) . . . . . . . . . . . . . . . . . . . . . .Overrange Indication (OR);
Ozone (O3) (0-1, 2, 3, 5, 10, 15, 25, 30, 50, 100) PPM . . . . . . . . . . . . . . . . . . . . . .Low Cal Factor Indication –
. . . . . . . . . . . . . . . . . . . . . .below 150 (SEN)
Ozone Rock Solid (O3) (0-1, 3, 5, 10, 15, 20, 25, 30) PPM
Local Inhibit . . . . . . . . . .Programmable: 3.0 to 20mA
Phosgene (0-1) PPM Temperature . . . . . . . . . .Sensor: See Capabilities Chart
Phosgene with HCN filter (0-2) PPM . . . . . . . . . . . . . . . . . . . . . .Transmitter: -40° to 140°F (-40° to
Phosphine (PH3) Rock Solid (0-500 PPB 1, 3, 5 PPM) . . . . . . . . . . . . . . . . . . . . . . . .60°C) LCD -40° to 140°F (-40° to
Phosphine (PH3) (0-1000 PPB, 3,10 PPM) . . . . . . . . . . . . . . . . . . . . . . . .60°C)* Note: at temperatures below
Silane (SiH4) (0-1000 PPB, 0-10 PPM) . . . . . . . . . . . . . . . . . . . . . . . . .22°F display may not be visible
Silicon Tetrafluoride (SiF4) Rock Solid (0-1, 3, 5) PPM
Humidity . . . . . . . . . . . . .Up to 99% RH, non-condensing
Sulfur Dioxide (SO2) Rock Solid (0-1, 3, 5, 10, 15, 25, 50, 30) PPM
(up to 100% R.H. with optional
Sulfur Dioxide (SO2) (0-10, 15, 25, 50, 100, 500) PPM humi-shield) Not recommended
TEOS (Si(O2H5)4 ) (0-50) PPM for continuous extreme high/low
Tungsten Hexafluoride (WF6) Rock Solid (0-1, 3, 5) PPM humidity applications

Warranties . . . . . . . . . . . .Transmitter: 1 Year


. . . . . . . . . . . . . . . . . . . . . .Sensor: 1 Year (except phosgen
. . . . . . . . . . . . . . . . . . . . . .sensor which is 7 months)
INSTALLATIONS
5000 AND 5600 ANALOG GAS TRANSMITTERS

SERIES 5000 SERIES 5600

FREEDOM® SERIES
5000 AND 5600 ANALOG GAS TRANSMITTERS

ELECTRICAL CONNECTIONS - SERIES 5600

ELECTRICAL CONNECTIONS - SERIES 5000

Monroe Corporate Center • P.O. Box 569 • Monroe, NC 28111


Telephone: 800.247.7257 • Facsimile: 704.291.8330
www.scotthealthsafety.com • sh-sale@tycoint.com
H/S 6715 4/08 ISO 9001 Registered. All rights reserved.