Experiment-1
Procedure:
i. Connections are made as shown in the circuit diagram. Set R1 and R2 to mid position
and V1 and V2 to minimum.
ii. Set the gate current Ig = Ig1 (such that forward break over voltage is between 15V to
20V), by varying R2 and V2.
iii. Slowly vary V1 in steps of 2V and note down VAK and IAK at each step till SCR
conducts. (Note down maximum VAK, which is forward break over voltage just before
SCR conducts).
Finding latching current
i. Ensure that the SCR is in the state of conduction.
ii. Start reducing anode voltage (VAK) in steps of 2V; simultaneously check the state of
SCR by switching off gate supply V2. If SCR switches off just by removing gate
terminal, and switches on by connecting gate supply, then the corresponding anode
current IA is the latching current (IL) for the SCR.
Finding holding current:
i. Ensure that the SCR is in the state of conduction.
ii. Switch off the gate supply permanently.
iii. Start reducing anode voltage (VAK) in steps of 2V; simultaneously check the state of
SCR. If SCR switches off. Note down the anode current (IA) just before it drops to
zero, which will be IH.
iv. Reverse the anode voltage polarity.
v. Vary VAK in steps of 5V till 25V and note down VAK and IA values at each step.
vi. Plot forward and reverse characteristics using the above-tabulated values. Find the
SCR forward resistance using the graph.
vii. Repeat the above procedure for the forward and reverse characteristics of SCR for a
gate current Ig = Ig2.
Result:
The values of VAK and IAK are noted down, plotted and SCR forward resistance is found. The
values obtained are verified.
Government Polytechnic Muzaffarpur
Name of the Lab: Power Electronics & Drives Lab
Subject Code: 1620607
Experiment-2
Aim: To study the operation of single phase fully controlled converter using R and RL load
and to observe the output waveforms.
Apparatus required:
i. Power Thyristors
ii. Rheostat
iii. CRO
iv. Transformer
v. Connecting wires
Circuit diagram:
Model graph:
Observation table:
S Triggering Output voltage Time period
No. angle α degree
1
2
3
Procedure:
i. Single Phase Fully Controlled Bridge Rectifier.
ii. Make the connections as per the circuit diagram.
iii. Connect CRO and millimetre (in dc) across the load.
iv. Keep the potentiometer (Ramp control) at the minimum position (maximum
resistance).
v. Switch on the step down ac source.
vi. Check the gate pulses at G1-K1, G2-K2, G3-K3, & G4-K4 respectively.
vii. Observe the waveform on CRO and note the triggering angle ‘α’ and note the
corresponding reading of the millimetre. Also note the value of maximum amplitude
Vm from the waveform.
viii. Set the potentiometer at different positions and follow the step given in (6) for every
position.
ix. Tabulate the readings in observation column.
x. Draw the waveforms observed on CRO.
Theory:
A fully controlled converter or full converter uses thyristors only and there is a wider control
over the level of dc output voltage. With pure resistive load, it is single quadrant converter.
Here, both the output voltage and output current are positive. With RL- load it becomes a
two-quadrant converter. Here, output voltage is either positive or negative but output current
is always positive. Figure shows the quadrant operation of fully controlled bridge rectifier
with R-load. Fig shows single phase fully controlled rectifier with resistive load. This type of
full wave rectifier circuit consists of four SCRs. During the positive half cycle, SCRs T1 and
T2 are forward biased. At ωt = α, SCRs T1 and T3 are triggered, then the current flows
through the L – T1- R load – T3 – N. At ωt = π, supply voltage falls to zero and the current
also goes to zero. Hence SCRs T1 and T3 turned off. During negative half cycle (π to 2π).
SCRs T3 and T4 forward biased. At ωt = π + α, SCRs T2 and T4 are triggered, then current
flows through the path N – T2 – R load- T4 – L. At ωt = 2π, supply voltage and current goes
to zero, SCRs T2 and T4 are turned off. The Fig-3, shows the current and voltage waveforms
for this circuit. For large power dc loads, 3-phase ac to dc converters are commonly used.
The various types of three-phase phase-controlled converters are 3 phase half-wave
converter, 3-phase semi converter, 3-phase full controlled and 3-phase dual converter. Three-
phase half-wave converter is rarely used in industry because it introduces dc component in
the supply current. Semi converters and full converters are quite common in industrial
applications. A dual is used only when reversible dc drives with power ratings of several MW
are required. The advantages of three phase converters over single-phase converters are as
under: In 3-phaseconverters, the ripple frequency of the converter output voltage is higher
than in single-phase converter. Consequently, the filtering requirements for smoothing out the
load current are less. The load current is mostly continuous in 3-phase converters. The load
performance, when 3- phase converters are used, is therefore superior as compared to when
single-phase converters are used.
( )( )
Result:
Thus the operation of single phase fully controlled converter using R and RL load has been
studied and the output waveforms has been observed.
Government Polytechnic Muzaffarpur
Name of the Lab: Power Electronics & Drives Lab
Subject Code: 1620607
Experiment-3
Observation table:
S Frequency Voltage amplitude(V) Time period(ms)
No.
1 Minimum
2 maximum
Procedure:
i. Switch on the firing circuit. Observe the trigger outputs TP and TN by varying
frequency potentiometer and by operating ON/OFF switch.
ii. Then connect input DC supply to the power circuit. Connect trigger outputs to Gate
and Cathode of SCR TP & TN.
iii. Apply trigger pulses to SCR
iv. Observe voltage waveforms across load. Output voltage is square wave only.
v. Vary the load, vary the frequency and observe waveforms.
Theory:
The circuit is a typical class C Parallel inverter. Assume TN to be ON and TP to be OFF. The
bottom of the commutating capacitor is charged to twice the supply voltage and remains at
this value until TP is turned on. When TP is turned on, the current flows through lower half of
the primary TP and commutating inductance L. Since voltage across C cannot
instantaneously, the common SCR cathode point rises approximately to 2V dc and reverses
bias TN. Thus TN turns off and C discharges through L, the supply circuit and then recharges
in the reverse direction. The autotransformer action makes C to charge making now its upper
point to reach +2V dc volts ready to commutate TP, When TN is again turned on and the cycle
repeats. Freewheeling diodes DP and DN assist the inverter in handling a wide range of loads
and the value of C may be reduced since the capacitor now does not have to carry the reactive
current. To dampen the feedback diode currents within the half period, feedback diodes are
connected to tapping of the transformer at 25V tapping.
Firing circuit:
This unit generates two pairs of pulse transformer isolated trigger pulses to trigger two SCR’s
connected in centre tapped transformer type parallel inverter. Frequency of the inverter can
be varied from 75Hz to 200 Hz approximately.
Power circuit:
This unit consists of two SCR’s, two freewheeling diodes, commutation inductor,
commutation capacitor and a centre tapped transformer to be inter connected to make parallel
inverter. All the points are brought out to the front panel. A switch and fuse is provided for
input DC supply. All the devices are mounted on proper heat sink. Each device is protected
by snubber circuit.
Result:
Thus the operation of a parallel inverter is studied and the output waveforms are measured
and drawn.
Government Polytechnic Muzaffarpur
Name of the Lab: Power Electronics & Drives Lab
Subject Code: 1620607
Experiment-5
Observation table:
S No. Amplitude(Volts) TON(ms) TOFF(ms)
1
Procedure:
i. To begin with switch on the power supply to the firing circuit check that Trigger
pulses by varying the frequency.
ii. Connections are made as shown in the circuit diagram. Now connect trigger outputs
from the firing circuits to gate and cathode of SCRs T1 & T2.
iii. Connect DC input from a 30V/2A regulated power supply and switch on the input DC
supply.
iv. Now apply trigger pulses to SCRs and observe voltage waveform across the load.
v. Measure VRMS & frequency of output voltage waveform.
Firing Circuit:
This part generates two pairs of pulse transformer isolated trigger two SCR’s connected as
series inverter. ON/OFF switch is provided for the trigger pulses which can be used to switch
ON the inverter. Frequency of the inverter can be varied from 100 Hz to 1 KHz
approximately.
Power Circuit:
This part consists of two SCRs & two diodes. A centre tapped inductor with tapings and 4
capacitors. Input supply terminals with ON/OFF switch and a fuse is provided. All the
devices in this unit mounted on a proper heat sink, snubber circuit for dv/dt protection and a
fuse in series with each device for short circuit protection. All the points are brought out to
front panel for inter connections. They have to be interconnected as shown in the circuit
diagram. Fly wheeling diodes can be connected across SCR’s and its effect can be observed.
Theory:
This circuit which converts DC power into AC power is called inverter. If the thyristor
commutation circuit of the inverter is in series with the Load, then the inverter is called
“Series are tightly coupled. In this circuit, it is possible to turn-on-thyristor Tp before the
current through thyristor Tn has become zero and vice-versa. Therefore, the Modified Series
Inverter can be operated beyond the resonance frequency (fr) of the circuit. Inverter is
operated at the resonance frequency (fr) if the load current waveform has low frequency and
should not have zero current interval. The inverter’s resonance frequency depends on the
values of L, R and C in the circuit.
Result:
Thus the operation of a series inverter is studied.
Government Polytechnic Muzaffarpur
Name of the Lab: Power Electronics & Drives Lab
Subject Code: 1620607
Experiment-6
Observation table:
S No. Duty cycle (%) Output voltage(V) Time period(ms)
1
2
3
Procedure:
i. Patch the voltage commutated chopper as per the circuit diagram.
ii. Connect the CRO probe across the commutated chopper.
iii. Give the input dc voltage (0-30)v, 2amps from the external power supply.
iv. Switch ON the trainer then switch ON the input dc supply circuit breaker.
v. After then switch ON the trigger OFF-ON position.
vi. From the capacitor output waveform we can measure the turn on time and turn off
time of main SCR as well as auxiliary SCR.
vii. Verify the unity and frequency of the triggering circuit using parts provided on the
triggering circuit.
viii. Also observe the voltage across main SCR and auxiliary SCR and load.
ix. Take the turn on and turn off time at main so auxiliary SCR from the capacitor
waveform at various values of unity cycle and frequency and tabulate them.
x. Also find out the peak value of current through the capacitor.
Theory:
Mode I:
Main SCR is triggered to make source current to flow in two path one is load current and
other path with triggering of SCR load get connected to supply and load voltage.
Mode II:
At a desired instant the auxiliary SCR is to be triggered for turning OFF the main SCR T1
with the switch ON, T2 reverse capacitance voltage appears across T1 which reverse biases it
and turn it OFF.
Mode III:
SCR T2 turn OFF since the capacitance is slightly changed after the freewheeling diode set
frequently forward biased.
Result:
Thus the operation of class D commutated technique has been obtained.
Government Polytechnic Muzaffarpur
Name of the Lab: Power Electronics & Drives Lab
Subject Code: 1620607
Experiment-9
Aim: To study the speed control of a dc motor by varying armature applied voltage through
phase controlled converter.
Apparatus required:
i. DC motor control unit
ii. DC armature
iii. DC voltmeter
iv. CRO
v. DC motor
Circuit diagram:
1
2
3
Result:
Thus the speed control of DC motor is performed by varying armature voltage through phase