KEYPLAN

NOTE:
ALL LEVELS AND DIMENSIONS BE VERIFIED ON THE SITE AND ADJUST DWG
AND LAYOUTS TO FIT SITE CONDITIONS
THIS DWG IS TO BE READ IN CONJUNCTION OF ALL OTHER DWG, FOR
SETTINGOUT, HARDSCAPE LAYOUT, SOFTSCAPE LAYOUT, LIGHTING LAYOUT,
IRRIGATION LAYOUT ETC. FOR PROPER CO-ORDINATION AND COHERENCE

400 x 400 mm TERRACOTTA TILES


AS STEPPING STONES WITH 150 mm
GAPS FILED WITH GRASS

150

150 400
GREY STONE BAND, EDGES WTIH
ROUND BULLNOSE

NOTE: TERRACOTTA TILES


START OF TILES HERRINGBONE PATTERN
ALIGN TILE WITH THE WALL EDGE

1 PLAN - TERRACOTTA STEPPING STONE LAYOUT


LD-200
SCALE 1:50

TERRACOTTA TILES

50 mm LEAN CONCRETE
150 400 150 400 150 400 150 400 x 400 x 250 mm
CONCRETE BASE

GRASS

PLANTING SOIL MIX


SUB-SURFACE
IRRIGATION SYSTEM

COMPOSED SUB-BASE

AA SECTION - TERRACOTTA STEPPING STONE


-
SCALE 1:10
KEYPLAN

NOTE:
ALL LEVELS AND DIMENSIONS BE VERIFIED ON THE SITE AND ADJUST DWG
AND LAYOUTS TO FIT SITE CONDITIONS
THIS DWG IS TO BE READ IN CONJUNCTION OF ALL OTHER DWG, FOR
SETTINGOUT, HARDSCAPE LAYOUT, SOFTSCAPE LAYOUT, LIGHTING LAYOUT,
IRRIGATION LAYOUT ETC. FOR PROPER CO-ORDINATION AND COHERENCE
KEYPLAN

NOTE:
ALL LEVELS AND DIMENSIONS BE VERIFIED ON THE SITE AND ADJUST DWG
AND LAYOUTS TO FIT SITE CONDITIONS
THIS DWG IS TO BE READ IN CONJUNCTION OF ALL OTHER DWG, FOR
SETTINGOUT, HARDSCAPE LAYOUT, SOFTSCAPE LAYOUT, LIGHTING LAYOUT,
IRRIGATION LAYOUT ETC. FOR PROPER CO-ORDINATION AND COHERENCE

Main Line Legend Sprinkler Line Legend:


Qty Symbol Description Part #
Qty Symbol Description Part # Pressure Flow Radius
10 drip outlet for ground cover and shrubs
14 INST5F- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 5F 2.1 0.48 1500
22 inline dripline 15 X 3.5 lph / tree
95 INST5H- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 5H 2.1 0.26 1500
60 inline dripline 22 X 3.5 lph / palm
36 INST5Q- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 5Q 2.1 0.13 1500
1 Hunter ICV101G- VALVE, 1" ELECTRIC GLASS FILLED NYLON (drip) ICV101G
20 INST8F- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 8F 2.1 1.1 2400
2 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON (drip) ICV151G
43 INST8H- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 8H 2.1 0.53 2400
2 Hunter ICV201G- VALVE, 2" ELECTRIC GLASS FILLED NYLON (drip) ICV201G
27 INST8Q- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 8Q 2.1 0.26 2400
1 New Water Source
7 INST8T- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 8T 2.1 0.35 2400
986.99 (m) PIPE, PVC CLASS 4 SJ 25MM OD PVCXC4SJ25
12 INST10F- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 10F 2.1 1.67 3000
195.19 (m) PIPE, PVC CLASS 4 SJ 32MM OD PVCXC4SJ32
5 INST10H- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 10H 2.1 0.84 3000
240.85 (m) PIPE, PVC CLASS 4 SJ 50MM OD PVCXC4SJ50
3 INST10Q- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 10Q 2.1 0.4 3000
33.88 (m) PIPE, PVC CLASS 4 SJ 63MM OD PVCXC4SJ63
20 INST12F- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 12F 2.1 2.55 3700
0.69 (m) PIPE, PVC CLASS 4 SJ 90MM OD PVCXC4SJ90
91 INST12H- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 12H 2.1 1.28 3700

31 INST12Q- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 12Q 2.1 0.66 3700

23 INST12T- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 12T 2.1 0.84 3700

9 INST15F- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 15F 2.1 3.83 4600

34 INST15H- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 15H 2.1 1.89 4600
Drip Line Legend:
10 INST15Q- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 15Q 2.1 0.97 4600
Qty Symbol Description
1 Hunter ICV101G- VALVE, 1" ELECTRIC GLASS FILLED NYLON (drip) 10 INST15T- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 15T 2.1 1.28 4600

2 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON (drip) 6 INST15TT- SPRINKLER SPRAY 4" POP-UP, 1/2" INLET - INST-04-CV 15TT 2.1 2.55 4600

1 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON (rotor) 1 LC- NOZZLE, CORNER STRIP LEFT 5FT X 15FT - SPRINKLER, SPRAY 4" POP-UP, BODY 1/2" LCS515 2.1 0.65 4600

6 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON (sprayer) 2 RC- NOZZLE, CORNER STRIP RIGHT 5FT X 15FT - SPRINKLER, SPRAY 4" POP-UP, BODY 1/2" RCS515 2.1 0.65 4600

2 Hunter ICV201G- VALVE, 2" ELECTRIC GLASS FILLED NYLON (drip) 2 MPR3000120-ROTATOR, MP3000 90-210 DEG. FTHD - SPRINKLER, SPRAY 4" POP-UP, BODY 1/2" MP300090 2.7 1.21 9000

6 Hunter ICV201G- VALVE, 2" ELECTRIC GLASS FILLED NYLON (sprayer) 10 MPR3000180-ROTATOR, MP3000 90-210 DEG. FTHD - SPRINKLER, SPRAY 4" POP-UP, BODY 1/2" MP300090 2.7 1.82 9000

17 VALVE, QUICK COUPLING 1" FEM. NPT INLET 3 MPR3000360-ROTATOR, MP3000 360 DEG. FTHD - SPRINKLER, SPRAY 4" POP-UP, BODY 1/2" MP3000360 2.7 3.64 9000

3 AVK VALVE,GATE FLANGED DN100 PN16 1 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON ICV151G

2 AVK VALVE,GATE FLANGED DN150 PN16 1 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON (rotor) ICV151G

6 AVK VALVE,GATE FLANGED DN80 PN16 5 Hunter ICV151G- VALVE, 1.5" ELECTRIC GLASS FILLED NYLON (sprayer) ICV151G

6 VALVE, AIR VACUUM AUTO/KINETIC 2" MTHD 3 Hunter ICV201G- VALVE, 2" ELECTRIC GLASS FILLED NYLON ICV201G

1 New Water Source 3 Hunter ICV201G- VALVE, 2" ELECTRIC GLASS FILLED NYLON (sprayer) ICV201G

70.6 (m) PIPE, PVC CLASS 5 RJ 160MM OD 1 New Water Source

120.17 (m) PIPE, PVC CLASS 5 SJ 110MM OD 1096.74 (m) Lateral - PIPE, PVC CLASS 4 SJ 25MM OD PVCXC4SJ25

239.83 (m) PIPE, PVC CLASS 5 SJ 90MM OD 142.41 (m) Lateral - PIPE, PVC CLASS 4 SJ 32MM OD PVCXC4SJ32

162.53 (m) Lateral - PIPE, PVC CLASS 4 SJ 50MM OD PVCXC4SJ50

42.77 (m) Lateral - PIPE, PVC CLASS 4 SJ 63MM OD PVCXC4SJ63


50cm

KEYPLAN

NOTE:
ALL LEVELS AND DIMENSIONS BE VERIFIED ON THE SITE AND ADJUST DWG
AND LAYOUTS TO FIT SITE CONDITIONS
THIS DWG IS TO BE READ IN CONJUNCTION OF ALL OTHER DWG, FOR
SETTINGOUT, HARDSCAPE LAYOUT, SOFTSCAPE LAYOUT, LIGHTING LAYOUT,
IRRIGATION LAYOUT ETC. FOR PROPER CO-ORDINATION AND COHERENCE

LF

DET DET DET


8 9
KEYPLAN

NOTE:
ALL LEVELS AND DIMENSIONS BE VERIFIED ON THE SITE AND ADJUST DWG
AND LAYOUTS TO FIT SITE CONDITIONS
THIS DWG IS TO BE READ IN CONJUNCTION OF ALL OTHER DWG, FOR
SETTINGOUT, HARDSCAPE LAYOUT, SOFTSCAPE LAYOUT, LIGHTING LAYOUT,
400 mm IRRIGATION LAYOUT ETC. FOR PROPER CO-ORDINATION AND COHERENCE

80

400

200
200

80
80
400

200
200
400 0/2