This document outlines minimum area requirements for cluster planning and dwelling units according to Indian standards and codes. It specifies that a minimum of 0.3 to 0.4 hectares of open space is required per 1000 people in a cluster. The maximum density is 500 dwelling units per hectare. A cluster must have a minimum width of 4.5 meters between other clusters. Room area requirements include a minimum of 15.5 square meters for a single multipurpose room, and 9 and 6.5 square meters for a two room unit. Three dwelling units require one WC and one bathroom. The minimum area per person in a dormitory is 7.5 square meters.
This document outlines minimum area requirements for cluster planning and dwelling units according to Indian standards and codes. It specifies that a minimum of 0.3 to 0.4 hectares of open space is required per 1000 people in a cluster. The maximum density is 500 dwelling units per hectare. A cluster must have a minimum width of 4.5 meters between other clusters. Room area requirements include a minimum of 15.5 square meters for a single multipurpose room, and 9 and 6.5 square meters for a two room unit. Three dwelling units require one WC and one bathroom. The minimum area per person in a dormitory is 7.5 square meters.
This document outlines minimum area requirements for cluster planning and dwelling units according to Indian standards and codes. It specifies that a minimum of 0.3 to 0.4 hectares of open space is required per 1000 people in a cluster. The maximum density is 500 dwelling units per hectare. A cluster must have a minimum width of 4.5 meters between other clusters. Room area requirements include a minimum of 15.5 square meters for a single multipurpose room, and 9 and 6.5 square meters for a two room unit. Three dwelling units require one WC and one bathroom. The minimum area per person in a dormitory is 7.5 square meters.
This document outlines minimum area requirements for cluster planning and dwelling units according to Indian standards and codes. It specifies that a minimum of 0.3 to 0.4 hectares of open space is required per 1000 people in a cluster. The maximum density is 500 dwelling units per hectare. A cluster must have a minimum width of 4.5 meters between other clusters. Room area requirements include a minimum of 15.5 square meters for a single multipurpose room, and 9 and 6.5 square meters for a two room unit. Three dwelling units require one WC and one bathroom. The minimum area per person in a dormitory is 7.5 square meters.
– Indian Standards for LIG Housing – National Building Code – UDPFI Recommendations
CLUSTER PLANNING REGULATIONS MINIMUM AREA
Minimum Open Space 0.3 Ha (1000 sq.m_ to 0.4 Ha per 1000 people Minimum open space between clusters 4.5m Maximum dwelling units per hectare 500 Vehicular Pathway Minimum 6m Pedestrian Pathway Minimum 3m Cluster to cluster width Minimum 4.5m
MINIMUM ROOM AREA REQUIREMENTS
One dwelling unit 4.5 persons Multipurpose single room 15.5 sq.m minimum Area in case of two rooms Minimum 9 sq.m and 6.5 sq.m for each room with width not less than 2.5m and 2.1m respectively WC requirement Not less than 0.9 sq.m with a minimum width 0.9m Bathroom requirement Not less than 1.2 sq.m - Minimum width of 1m Minimum combined toilets area 1.8 sq.m area with minimum width of 1m Three Dwelling units (13.5 people) requires 1 WC and 1 Bath Minimum area required per person in a 7.5 sq.m dormitory Spatial requirement limit per person 7.5 - 12.5 sq.m Maximum travel distance between exits 30m