Sample Plumbing Estimate

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

EXAMPLE


A public CR have the following fixtures
and Pipe
EXAMPLE
Determine the man hour needed to install
the fixtures
EXAMPLE


EXAMPLE
7 – WC * 1.8hr
5 – Lav * 2.0hr
2 – UR * 2.8hr

= 28.2 man-hr

This is the duration of fixture installation if


done by a single person
EXAMPLE

Determine the time it takes to install the
fittings in the pipes
EXAMPLE
The fittings that will be needed are as follows:
9 – Tee Reducers (use 25mm)
5 – 900 25mm Elbow 2 – 900 13mm elbow
2 – Tee 25mm
5 – 13mm Tee
Distribution Pipe diameter is 25mm
Branch Fixture diameter is 13mm
Length of pipe is 15m
EXAMPLE


EXAMPLE
Since the pipe is plastics and the total
25mm joints are 16pcs
For solvent connection (plastic)
16 joints
∗25 hrs=4 hrs
100 joints
For screwed connection
16 joints
∗30 hrs=4.8 hrs
100 joints
For hot fusion
16 joints
∗25 hrs∗1.5=6 hrs
100 joints
EXAMPLE
Since the pipe is plastics and the total
13mm joints are 7pcs
For solvent connection
7 joints
∗20 hrs=1.4 hrs
100 joints
For screwed connection
7 joints
∗25 hrs=1.75 hrs
100 joints
For hot fusion
7 joints
∗20 hrs∗1.5=2.1 hrs
100 joints

You might also like