Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Customer : PIA Manual : AMM

Type : A318/A319/A320/A321 Selected applicability : ALL


Rev. Date : Feb 01, 2019
52-73-12 PB 401 CONF 00 - PRESSURE SWITCH - CABIN
PRESSURE DETECTION - REMOVAL/INSTALLATION

** ON A/C ALL

52-73-12 PB 401 CONF 00 - PRESSURE SWITCH - CABIN


PRESSURE DETECTION - REMOVAL/INSTALLATION

TASK 52-73-12-000-001-A
Removal of the Cabin-Pressure Detection Pressure-Switch

WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN
CAUSE DAMAGE TO THE EQUIPMENT.

FIN : 14WN
1. Reason for the Job
Self explanatory
2 Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTY DESIGNATION


No specific AR ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific AR CAP - BLANKING
No specific AR PLUG - BLANKING
No specific AR SAFETY CLIP - CIRCUIT BREAKER

B. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


122 AVIONICS COMPARTMENT
811

C. Referenced Information

REFERENCE DESIGNATION
(Ref. 24-42-00-861-001-A). Energize the Ground Service Network from the External Power
Cabin Pressure Detection Pressure Switch - (14WN) SHEET 1

Print Date: March 04, 2019 Page 1 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : PIA Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Feb 01, 2019
52-73-12 PB 401 CONF 00 - PRESSURE SWITCH - CABIN
PRESSURE DETECTION - REMOVAL/INSTALLATION

14WN

FR2

DOOR 811

FR1 A 8
7

3
2
1

2
4
3

N_MM_527312_4_AAM0_01_00

Figure 52-73-12-991-00100-00-A / SHEET 1/1 - Cabin Pressure Detection Pressure Switch - (14WN)
** ON A/C ALL

Print Date: March 04, 2019 Page 2 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : PIA Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Feb 01, 2019
52-73-12 PB 401 CONF 00 - PRESSURE SWITCH - CABIN
PRESSURE DETECTION - REMOVAL/INSTALLATION

3. Job Set-up
Subtask 52-73-12-860-050-A
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001)
Subtask 52-73-12-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):

PANEL DESIGNATION FIN LOCATION


121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11
121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10
Subtask 52-73-12-010-050-A
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 122.
(2) Open the avionics compartment access door 811.
4. Procedure
Subtask 52-73-12-020-050-A
A. Removal of the Pressure Switch
(Ref. Fig. Cabin Pressure Detection Pressure Switch - (14WN) SHEET 1)
(1) Disconnect the electrical connector (4).
(2) Put a CAP - BLANKING on the electrical connector (4).
(3) Remove and retain the calibrated plug (1).
(4) Put a PLUG - BLANKING in the plug calibrated hole part on the pressure switch.
(5) Disconnect the line (8).
(6) Remove the restrictor (7) with the O-ring (6).
(7) Discard the O-ring (6).
(8) Put a PLUG - BLANKING on the connection of the line (8).
(9) Remove the bolts (3) and the washers (2).
(10) Remove the pressure switch (5).

TASK 52-73-12-400-001-A
Installation of the Cabin-Pressure Detection Pressure-Switch

FIN : 14WN
1. Reason for the Job
Self explanatory
2 Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTY DESIGNATION


No specific AR CAP - BLANKING

Print Date: March 04, 2019 Page 3 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : PIA Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Feb 01, 2019
52-73-12 PB 401 CONF 00 - PRESSURE SWITCH - CABIN
PRESSURE DETECTION - REMOVAL/INSTALLATION

REFERENCE QTY DESIGNATION


No specific AR PLUG - BLANKING
No specific Torque wrench: range to between 0.36 and 0.40 m.daN
(31.86 and 35.40 lbf.in)
No specific Torque wrench: range to between 0.695 and 0.705 m.daN
(61.50 and 62.39 lbf.in)

B. Work Zones and Access Panels

ZONE/ACCESS ZONE DESCRIPTION


122 AVIONICS COMPARTMENT
811

C. Expendable Parts

FIG.ITEM DESIGNATION IPC-CSN


6 O-ring 52-73-01-02-030
6 O-ring 52-73-81-02-030

D. Referenced Information

REFERENCE DESIGNATION
(Ref. 24-42-00-861-001-A). Energize the Ground Service Network from the External Power
(Ref. 24-42-00-862-001-A). De-energize the Ground Service Network Supplied from the External
Power
(Ref. 34-22-25-790-001-A). Low range Leak Test of the Standby Pneumatic circuits
(Ref. 52-73-00-720-003-A). Operational Test of the Residual Cabin Pressure Warning System
and In-Situ Functional Test of the Cabin Pressure Detection Pres-
sure-Switch
Cabin Pressure Detection Pressure Switch - (14WN) SHEET 1

3. Job Set-up
Subtask 52-73-12-860-051-A
A. Aircraft Maintenance Configuration
(1) Make sure that the access door 811 is open, and that the access platform is in position.
(2) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001) .
Subtask 52-73-12-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:

PANEL DESIGNATION FIN LOCATION


121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11
121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10
4. Procedure
Subtask 52-73-12-420-050-A
A. Installation of the Pressure Switch
(Ref. Fig. Cabin Pressure Detection Pressure Switch - (14WN) SHEET 1)
(1) Remove the PLUG - BLANKING from the connection of the line (8).

Print Date: March 04, 2019 Page 4 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : PIA Manual : AMM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Feb 01, 2019
52-73-12 PB 401 CONF 00 - PRESSURE SWITCH - CABIN
PRESSURE DETECTION - REMOVAL/INSTALLATION

(2) Install the IPC -CSN (52-73-01-02-030) O-ring (6) or IPC -CSN (52-73-81-02-030) O-ring (6) on the
restrictor (7).
(3) Install the restrictor (7) on the pressure switch (5) and tighten it.
(4) TORQUE the restrictor (7) to between 0.36 and 0.40 m.daN (31.86 and 35.40 lbf.in).
(5) Remove the PLUG - BLANKING from the calibrated plug hole (1).
(6) Install the calibrated plug (1) on the pressure switch (5) and tighten it.
(7) Put the pressure switch (5) in position on its support.
(8) Install the bolts (3) and the washers (2) and tighten the bolts.
(9) Install the line (8) on the restrictor (7).
(10) TORQUE the line (8).

CAUTION: USE A SECOND WRENCH TO HOLD THE MATING PARTS WHEN YOU LOOSEN
OR TIGHTEN THE TUBE OR HOSE NUTS. IF YOU DO NOT OBEY THIS CAUTION,
YOU CAN TWIST OR CAUSE DAMAGE TO THE TUBES OR HOSES.

(a) TORQUE the line (8) to between 0.695 and 0.705 m.daN (61.50 and 62.39 lbf.in).
(11) Remove the CAP - BLANKING from the electrical connector (4).
(12) Connect the electrical connector (4) to the pressure switch (5).
Subtask 52-73-12-720-050-B
B. Functional Test
(1) Do the in-situ functional test of the pressure switch (14WN) (Ref. AMM TASK 52-73-00-720-003) .
(2) Do the low range leak test of standby pneumatic circuits (Ref. AMM TASK 34-22-25-790-001) .
5. Close-up
Subtask 52-73-12-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):

PANEL DESIGNATION FIN LOCATION


121VU EIS/SLIDES/ARM AND WARN/FLT 15WN P11
121VU EIS/SLIDES/ARM AND WARN/GND 13WN P10
Subtask 52-73-12-410-050-A
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the avionics compartment access door 811.
(3) Remove the access platform(s).
Subtask 52-73-12-860-052-A
C. Aircraft Maintenance Configuration
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
Figure 52-73-12-991-00100-00-A / SHEET 1/1 - Cabin Pressure Detection Pressure Switch - (14WN)

End of document

Print Date: March 04, 2019 Page 5 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.