Installation and Signal converters IFC 011 operating for instructions electromagnetic flowmeters Aquamag & Ecomag How to use these Instructions The flowmeters are supplied ready for operation The primary head must be installed in the pipeline as described in the installation instructions. - Installation location and connection to power (Section 1) Pages 1/1-1/4 - Electrical connection of outputs (Section 2) Pages 2/1 - Factory settings and start-up (Section 3) Pages 3/1-3/2 Power the flowmeter. THAT’S ALL. The system is operative. Operator control of the IFC 011 signal converter is described in Sections 4. Contents System descri 0/4 Product liability and warranty 0/4 Measuring principle and function of the system O15 Block diagram - signal converter 016 Features of the IFC 011 07 Part A__ System installation and start-up 41-312 1 Electrical connection: power supply 4-114 1.1 Important installation notes 1 1.2. Connection to power 12 1.3. Electrical connection of separate primary head (F Version) 113-116 1.3.1 General information on signal cable A and field current cable 113 1.3.2 Grounding of primary head 113 1.3.3 Connection diagrams (Primary Head, converter) 113 1.3.4 — Connection diagrams (Primary Head, converter) 14 2 Electrical connection of outputs 2 24 Current output 2A 2.2 Connection diagrams for output 2n 3. Start-up 3M 3.1 Switch-on and measurement 3 3.2 Factory settings 3 Part B IFC 011 Signal converter 41-519 4 Operation of the signal converter 41-418 41 Krohne operator control concept an 42 Operating and check elements 4l2 4.3. Function of keys 413-414 4.4 Table of settable functions 415-416 4.5 Error messages in measuring mode 4i7 4.6 Reset totalizer and cancel error messages, RESET/QUIT menu 4/8 47 Examples of setting the signal converter 418 5 Description of functions 511-512 54 User-defined unit 5it 5.2 FIR mode, forwardireverse flow measurement 5/2 53 Characteristic of outputs 5/2 on Part Special applications, functional checks, service, and order numbers __6/1-8/2 6 Special applications si z Functional checks TA-116 7.41 Zero check with IFC 011, signal converter, Fet. 64 7H 7.2 Test Funtion 7H 7.3. Faults and symptoms during start-up and process flow measurement 72 7.4 Testof primary head 713 7.5 Test of signal converter using GS 8A simulator (option) 714-716 8 Service 8/1-8/2 8.1 Replacement of power fuses ait 8.2 Changeover of operating voltage ait 83 IFC 011 Replacement of converter electronic unit 8/2 PartD Technical data, measuring principle and block diagram 10/1-10/10] 10___ IFC 011 Technical data 10/1 10.1 Fulkscale range Qioox, 10/1 10.2 Aquamag/Ecomag Installation dia with IFC 011 converter 1012 10.3 Stud for (Aqua /Eco mag) 10/3 10.4 Mating flange 10/4 10.5 Aqua-mag SEP VER. with AL.con.box 1015 10.6 AqualEco Mag Integral version 1016 10.7 Eco/Aqua mag separate version 10/7 10.8 Dimension details of separate version 10/8 10.9 Error Limits 10/9 10.10 IFC011 Signal convertor 10/9 10.11 Instrument name plates, 10/10 Printed form to accompany flowmeters returned to Krohne 3 02

You might also like