Installation and
Signal converters IFC 011 operating
for instructions
electromagnetic flowmeters
Aquamag & Ecomag
How to use these Instructions
The flowmeters are supplied ready for operation
The primary head must be installed in the pipeline as described in the installation
instructions.
- Installation location and connection to power (Section 1) Pages 1/1-1/4
- Electrical connection of outputs (Section 2) Pages 2/1
- Factory settings and start-up (Section 3) Pages 3/1-3/2
Power the flowmeter. THAT’S ALL. The system is operative.
Operator control of the IFC 011 signal converter is described in Sections 4.Contents
System descri 0/4
Product liability and warranty 0/4
Measuring principle and function of the system O15
Block diagram - signal converter 016
Features of the IFC 011 07
Part A__ System installation and start-up 41-312
1 Electrical connection: power supply 4-114
1.1 Important installation notes 1
1.2. Connection to power 12
1.3. Electrical connection of separate primary head (F Version) 113-116
1.3.1 General information on signal cable A and field current cable 113
1.3.2 Grounding of primary head 113
1.3.3 Connection diagrams (Primary Head, converter) 113
1.3.4 — Connection diagrams (Primary Head, converter) 14
2 Electrical connection of outputs 2
24 Current output 2A
2.2 Connection diagrams for output 2n
3. Start-up 3M
3.1 Switch-on and measurement 3
3.2 Factory settings 3
Part B IFC 011 Signal converter 41-519
4 Operation of the signal converter 41-418
41 Krohne operator control concept an
42 Operating and check elements 4l2
4.3. Function of keys 413-414
4.4 Table of settable functions 415-416
4.5 Error messages in measuring mode 4i7
4.6 Reset totalizer and cancel error messages, RESET/QUIT menu 4/8
47 Examples of setting the signal converter 418
5 Description of functions 511-512
54 User-defined unit 5it
5.2 FIR mode, forwardireverse flow measurement 5/2
53 Characteristic of outputs 5/2
onPart Special applications, functional checks, service, and order numbers __6/1-8/2
6 Special applications si
z Functional checks TA-116
7.41 Zero check with IFC 011, signal converter, Fet. 64 7H
7.2 Test Funtion 7H
7.3. Faults and symptoms during start-up and process flow measurement 72
7.4 Testof primary head 713
7.5 Test of signal converter using GS 8A simulator (option) 714-716
8 Service 8/1-8/2
8.1 Replacement of power fuses ait
8.2 Changeover of operating voltage ait
83 IFC 011 Replacement of converter electronic unit 8/2
PartD Technical data, measuring principle and block diagram 10/1-10/10]
10___ IFC 011 Technical data 10/1
10.1 Fulkscale range Qioox, 10/1
10.2 Aquamag/Ecomag Installation dia with IFC 011 converter 1012
10.3 Stud for (Aqua /Eco mag) 10/3
10.4 Mating flange 10/4
10.5 Aqua-mag SEP VER. with AL.con.box 1015
10.6 AqualEco Mag Integral version 1016
10.7 Eco/Aqua mag separate version 10/7
10.8 Dimension details of separate version 10/8
10.9 Error Limits 10/9
10.10 IFC011 Signal convertor 10/9
10.11 Instrument name plates, 10/10
Printed form to accompany flowmeters returned to Krohne 3