Maintenance Manual of Trailer Concrete Pump
A4VG Series 40
RE-A 92004
Edition: 09.2017
Americas Replaces: 06.2012
Features Contents
▶ High power density owing to a very high pressure level Type code 2
▶ Integrated auxiliary pump for boost and pilot oil supply Hydraulic fluid 6
▶ Flow direction changes smoothly when the swashplate is Working pressure range 7
Technical data 9
moved through the neutral position
HP – Proportional control, hydr., pilot-pressure related 12 HW –
▶ High-pressure relief valves with integrated boost Proportional control, hydr., mechanical servo 13
function HT – Hydraulic control, direct operated 15
▶ With adjustable pressure cut-off as standard DA – Automatic control, speed related 16
▶ Boost-pressure relief valve EP – Proportional control, electric 18
EZ – Two-point control, electric 19
▶ Through drive for mounting of further pumps up to same nominal
ET – Electric control, direct operated 20
size Dimensions, size 110 to 280 21
▶ High total efficiency Dimensions, through drive 41
▶ Large variety of controls Overview of mounting options 45
▶ Swashplate design Combination pumps A4VG + A4VG 46
High-pressure relief valves 47
Pressure cut-off 48
Bypass function 48
Neutral valve 49
Mechanical stroke limiter 50
Stroking chamber pressure port X3 and X4 51
Filtration in the boost pump suction line 52
Filtration in the boost pump pressure line 52
External boost pressure supply 54
Dimensions with mounted filter 55
Swivel angle sensor 56
Connector for solenoids 57
Speed sensor 58
Installation dimensions for coupling assembly 59
Installation instructions 60
Project planning notes 63
Safety instructions 64
Type code
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A4V G / 40 A N A 0 −
Operating mode
02 Pump, closed circuit G
Size (NG)
03 Geometric displacement, see “Technical data” on page 9 in3/rev. 6.71 7.63 8.85 10.68 12.81 17.09
cm3/rev. 110 125 145 175 210 280
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A4V G / 40 A N A 0 −
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A4V G / 40 A N A 0 −
Boost pump and rotary group configuration 110 125 145 175 210 280
17 Standard rotary group boost pump integrated, standard internal gear pump ● ● ● ● ● ● F
boost pump integrated, large internal gear pump ● – ● ● ● – B
without boost pump ● ● ● ● ● ● U
High-speed rotary group boost pump integrated, standard internal gear pump ● – ● ● – – V
without boost pump ● – ● ● – – W
5) Only possible without attachment filter. 7) Hub for splined shaft according to ANSI B92.1a-1976 (drive shaft allocation
6) Specifications for version with integrated standard gear pump, please according to SAE J744)
contact us for version with integrated large gear pump or without boost 8) Mounting hole pattern viewed on through drive
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
A4V G / 40 A N A 0 −
Notice
▶ Note the project planning notes on page 63!
▶ In addition to the type code, please specify the rel- evant
technical data when placing your order.
10) Specify type code of sensor acc. to data sheet (DSM - 95132, DSA
95133) separately and observe the requirements on the elec- tronics
Hydraulic fluid
The axial piston unit is designed for operation with HLP Notes on selection of hydraulic fluid
mineral oil according to DIN 51524. The hydraulic fluid should be selected so that the operating
Application instructions and requirements for hydraulic fluid viscosity in the operating temperature range is within the optimum
selection, behavior during operation as well as dis- posal and range (νopt see selection diagram).
environmental protection should be taken from the following data
sheets before the start of project plan- ning:
▶ 90220: Hydraulic fluids based on mineral oils and related
hydrocarbons
▶ 90221: Environmentally acceptable hydraulic fluids
▶ 90222: Fire-resistant, water-free hydraulic fluids
(HFDR/HFDU)
▶ 90225: Limited technical data for operation with water- free and
water-containing fire-resistant hydraulic fluids (HFDR, HFDU,
HFAE, HFAS, HFB, HFC)
▼ Selection diagram
SUS (mm2/s)
Maximum permissible viscosity for cold start
7400 (1600)
Warm-up phase 4600 (1000)
2800 (600)
1850 (400)
930 (200)
460 (100)
Viscosity ν
60 (10)
Minimum permissible viscosity at short-term operation
49 (7)
−40 −13 14 32 50 86 104 122 158 195 240
(−40) (−25) (−10) (0) (10) (30)(40)(50) (70) (90) (115)
Temperature θ [°F (°C)]
1) Corresponds e.g. for VG 46 to a temperature range of +39 °F (+4 °C) 2) Special version, please contact us
to +185 °F (+85 °C) (see selection diagram) 3) Ifthe temperature at extreme operating parameters cannot be adhered
to, please contact us.
t2
Single operating period t1 tn
Maximum pressure pmax
Nominal pressure pnom
Pressure p
Time t
[psi (bar)]
75 (5)
60 (4)
Differential pressure Ap
45 (3)
NG110, 125
30 (2) NG210 NG14 5
0
1000 2000 3000 4000 5000
Rotational speed n [rpm]
Technical data
rounded 3) The data are valid for values between the minimum required and
Vg × Δp Vg × Δp
[lb-ft]
Torque T =
24 × π × ηhm
( 24 × π × η ) [Nm]
hm
2 π × T × n qv × Δp 2 π × T × n qv × Δp × ηt 33000
Power P = = [HP]
1714 × ηt ( =
60000
[kW]
600 )
Key
Vg Displacement per revolution [in3 (cm3)]
Δp Differential pressure [psi (bar)]
n Rotational speed [rpm]
ηv Volumetric efficiency
ηmh Hydraulic-mechanical efficiency
ηt Total efficiency (ηt = ηv × ηmh)
Notice
▶ The axial and radial forces generally influence the
service life of the bearings.
▶ Special requirements apply in the case of belt drive and
cardan shaft. Please contact us.
▼ Distribution of torques
T1 T2
TE
1st pump 2nd pump
T3
TD
The output flow of the pump is infinitely variable between ▼ Circuit diagram, standard version
0 and 100%, proportional to the difference in pilot pressure applied R Y1 Y2
to the two pilot pressure ports (Y1 and Y2).
The pilot signal, coming from an external source, is a pres- sure
signal. Flow is negligible, as the pilot signal acts only on the
X1 X2
control spool of the control valve.
This control spool then directs control oil into and out of the T1 MH PS YST MB B
stroking cylinder to adjust pump displacement as required.
A feedback lever connected to the stroking piston maintains the
pump flow for any given pilot signal within the control range.
The output flow of the pump is infinitely variable between 0 and Option: Neutral position switch
100%, proportional to the swivel angle of the control lever. The switch contact in the neutral position switch is closed when
A feedback lever connected to the stroking piston maintains the the control lever on the HW control module is in its neutral
pump flow for any given position of the control lever. position. The switch opens when the control lever is moved out of
If the pump is also equipped with a DA control valve (see the central position in either direction.
page 16), automotive operation is possible for travel Thus, the neutral position switch provides a monitoring function
drives. for drive units that require the pump to be in the neutral position
β [°] during certain operating conditions
(e.g. starting diesel engines).
40
35
30 Technical data
25
20 Load capacity 20 A (continuous), without switching operations
15 Switching capacity 15 A / 32 V (resistive load)
10
4 A / 32 V (inductive load)
5
0 Connector version DEUTSCH DT04-2P-EP04
Vg 1.0 0.8 0.6 0.4 0.2 5 0 0.2 0.4 0.6 0.8 1.0 Vg
(mating connector, see page 57)
10
Vg max Vg max
15
20
▼ Circuit diagram, standard version
25
30 R
35
40
β [°] a b
X1 X2
X1 MB, MA B, A
b
B
MB
MA
a A
X2
With the direct operated hydraulic control, the output flow of the
pump is controlled by a hydraulic control pressure, applied X1 X2
X1 M , M
B A
directly to the stroking piston through either
port X1 or X2. B
B, A MB
Flow direction is determined by which control pressure port is
MA
pressurized (refer to table below).
Pump displacement is infinitely variable and proportional to the A
applied control pressure, but is also influenced by system
YHT X2
pressure and pump drive speed.
In order to use the optional built-in pressure cut-off, port YHT
must be used as the control pressure source for the selected Correlation of direction of rotation, control and flow direction
control module. See page 48 for a functional description of Direction of rotation clockwise counter-clockwise
the pressure cut-off. Control pressure X1 X2 X1 X2
Maximum permissible control pressure: 580 psi (40 bar) Use of Flow direction B to A A to B A to B B to A
the HT control requires a review of the engine and vehicle MA MB MB MA
Working pressure
parameters to ensure that the pump is set up cor- rectly. We
recommend that all HT applications be reviewed by a Bosch
Rexroth application engineer.
▼ Circuit diagram
R YHT
X1 X2
T1 MH PS YST MB B
T2 G S MA A
Solenoid b X2
DA..1 − DA control valve, fixed setting DA..6 − DA control valve, fixed setting, ports for pilot control
Pilot pressure is generated in relation to drive speed. device as inch valve
Any reduction of the pilot pressure possible, independent of the
▼ Circuit diagram drive speed is achieved by the mechanical actuation of the pilot
R control device.
The pilot control device is installed separately from the
a b pump (for example in the driver’s cabin) and connected to
the pump by two hydraulic control lines via ports PS and YST. A
X1 X2
suitable pilot control device must be ordered separately and is not
T1 MH PS YST MB B included in the scope of delivery.
▼ Circuit diagram
a b
X1 X2
YST
T1 MH PS MB B
T2 G S MA A
▼ Circuit diagram
R
Z
X2
a b
X1
T1 MH PS YST MB B
T2 G S MA A
EP – Proportional control,electric
The output flow of the pump is infinitely variable between 0 and Various BODAS controllers with application software and
100%, proportional to the electrical current supplied to solenoid a amplifiers are available for controlling the proportional
or b. solenoids.
The electrical energy is converted into a force acting on the control Further information can also be found on the Internet at
spool. www.boschrexroth.com/mobile-electronics
This control spool then directs control oil into and out of the
stroking cylinder to adjust pump displacement as required. ▼ Circuit diagram
A feedback lever connected to the stroking piston maintains the R
pump flow for any given current within the control range.
If the pump is also equipped with a DA control valve (see a b
1200 EP1, 3
1000
800
600 EP2, 4
400
200
0
Vg 1.0 0.8 0.6 0.4 0.2 0 0.2 0.4 0.6 0.8 1.0 Vg
I [mA] (Solenoid b)
X1 X2
Solenoid a
X1 MB, MA
B
B, A
MB
Notice MA
The proportional solenoids in version EP1/EP2 do not have
A
manual override. Proportional solenoids with manual override and
X2
spring return are available on request (version EP3/EP4). Solenoid b
Correlation of direction of rotation, control andflow direction
Technical data, solenoid EP1, 3 EP2, 4
Direction of rotation clockwise counter-clockwise
Voltage 12 V (±20%) 24 V (±20%)
Actuation of sole- noid a b a b
Control current
Start of control at Vg = 0 400 mA 200 mA Control pressure X1 X2 X1 X2
End of control at Vg max 1200 mA 600 mA Flow direction B to A A to B A to B B to A
Current limit 1.54 A 0.77 A Working pressure MA MB MB MA
Nominal resistance (at 68 °F (20 °C)) 5.5 Ω 22.7 Ω
Dither
Frequency 100 Hz 100 Hz
minimum oscillation range1) 240 mA 120 mA
Duty cycle 100% 100%
1) Minimumrequired oscillation range of the control current ΔIp-p (peak to
Type of protection: see connector version page 57
peak) within the respective control range (start of control to end of control)
EZ – Two-point control,electric
By actuating either switching solenoid a or b, internal control Correlation of direction of rotation, control and flow direction
pressure is applied directly to the stroking piston and the pump Direction of rotation clockwise counter-clockwise
swivels to maximum displacement. The EZ control enables pump Actuation of solenoid a b a b
flow to be switched between Vg = 0 and Vg max. Control pressure X2 X1 X2 X1
Flow direction is determined by which solenoid is energized. Flow direction A to B B to A B to A A to B
Working pressure MB MA MA MB
Technical data, solenoid EZ1 EZ2
Voltage 12 V (±20%) 24 V (±20%) X1 X2
Solenoid a
Neutral position Vg = 0 de-energized de-energized X1 MB, MA
Position Vg max Current Current
B, A B
switched on switched on
MB
Nominal resistance (at 68 °F (20 °C)) 5.5 Ω 21.7 Ω
MA
Nominal power 26.2 W 26.5 W
A
Minimum active current required 1.32 A 0.67 A
Duty cycle 100% 100% Solenoid b X2
Type of protection: see connector version page 57
▼ Circuit diagram
a b
X1 X2
T1 MH PS YST MB B
T2 G S MA A
The output flow of the pump is infinitely variable between 0 and Correlation of direction of rotation, control and flow direction
100%. Depending on the preselected current I at solenoids a Direction of rotation clockwise counter-clockwise
and b of the pressure reducing valves, the stroking cylinder of Actuation of solenoid a b a b
the pump is proportionally supplied with control pressure. The Control pressure (in X1 X2 X1 X2
pump displacement that arises at a certain control current is X3, X4 optional) X3 X4 X3 X4
dependent on the speed and working pressure of the pump. A Flow direction B to A A to B A to B B to A
different flow direction is associated with each pressure reducing Working pressure MA MB MB MA
valve. Maximum permissible control pressure: 580 psi (40 bar).
Technical data, solenoid ET5 ET6
Voltage 12 V (±20%) 24 V (±20%)
X1 MB,MA B, A
Solenoid a X1 X2
Current limit 1.54 A 0.77 A
B
Nominal resistance (at 68 °F (20 °C)) 5.5 Ω 22.7 Ω MB
Dither
Frequency 100 Hz 100 Hz MA
1)
minimum oscillation range 240 mA 120 mA A
Duty cycle 100% 100%
X2 Solenoid b
Type of protection: see connector version page 57
▼ Circuit diagram
a b
X1 X2
T1 MH PS YST MB B
T2 G S MA A
7.34 (186.4)
PS MH
7.18 (182.4)
1.2(30.5)
T1
5.91(150)
(25.1)2)
0.99
(YST)
(PS)
(Ø152.4 -0.063)
DIA5.998
DIA6.000
(161.6)
(G)
0
6.36
1.77
(45)
0.59(15)
5.2 (132)
(116.3)
(T )1
3.86
0.83
(98)
4.58
(21)
0.71
Flange D6 (18) T2
(S)
SAE J744
(T1) 5.02(127.5) G S YST
2) X
6.46 (164.2) 6.36
(161.6)
(YST, G) 7.89 (200.5)
9
(PS) 8.07 (205.1) (228.6)
(S) 10.18 (258.5)
12.53 (318.3)3)
MB
X1 B, A B
(B, A)
(109.2)
0.2 (5)
3.74
(95)
4.3
(85.5)
S
3.37
3.27
(83)
R
(S)
2.91
(85.5)
(74)
3.37
(109.2)
3.27
(83)
(123.5)
4.3
MH
ST, G) 4.86
A M A T2 5.69
(144.5)
6.83 X2 PS, YST,G 9.95
(PS,Y
(173.5) (252.7)
Detail view of mounting
flange C6 (optional)
0.59 (15) 4-hole
0.71 (18) 2-hole
0.5
(12.7) Detail X
(Ø127-0.063)
DIA4.998
DIA5.000
0.98
(27.8)
1.09
0
(25)
2.25
(57.2)
Flange C6
SAE J744
1) ForSAE working ports A and B, 45° right (viewed on drive shaft), the 3) Valid for version with standard internal gear pump,
complete case and thus the dimensions are mirrored. overall length without boost pump and with large internal gear pump,
2) Center of gravity see through drive, page 41
5/8-11UNC-2B2)
1.89 (48)
1.10 (28) 1.42
(36)
0.37 0.47
(9.5) (12)
DIA3.98 (Ø101)
DIA3.98 (Ø101)
DIA2.17
DIA2.17
(Ø55)
(Ø55) 2.17 (55)
1.57 (40)
2.20 (56) 2.95 (75)
3.15 (80)
5/8-11UNC-2B2)
1.42 (36)
0.45
(11.4)
DIA3.98 (Ø101)
DIA2.17
(Ø55)
2.60 (66)
3.46 (88)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat root, 2) Thread according to ASME B1.1
side fit, tolerance class 5
3) Depending on the application, momentary pressure peaks can oc- cur. 7) The countersink can be deeper than as specified in the standard.
Keep this in mind when selecting measuring devices and fit- tings. 8) Optional,see page 51
4) Only dimensions according to SAE J518. 9) For the maximum utilization of pressure, only grade 8 screws and hardened
5) Plugged for external boost pressure supply. washers are to be used to tighten the SAE flange shells.
6) Depending on installation position, T1 or T2 must be connected (see also 10) O = Must be connected (plugged when delivered) X =
▼oH
po
Wrt–
ioP
narl control, hydraulic, mechanical servo ▼ EZ – Two-point control, electric
0.31
1.06 (260.4)
(8)
(27)
DIA0.31 (Ø8)
(150)
5.91
(197.8)
7.79
Version with
neutral position
switch, HW8
(100.4) (100.4)
3.95
0.79
(20)
3.95
2.68
(68)
10.17
(258.4)
(151.5)
5.96
(109.2) (109.2)
4.3 4.3
DA control valve
▼ DA..1 – fixed setting ▼ DA..5 – fixed setting and inch valve mounted
10.28 (261)
10.28 (261) 10.25 (260.4)
10.25 (260.4) 4.7
(119.4)
(230)
9.06
(150)
5.91
(150)
5.91
0.20
0.20
(5)
(5)
(max. 81.5)
max. 3.21
X1
3.95
(100.4)(100.4)
(100.4) (100.4)
3.95
R
(110.5)
3.11
(79)
(max. 183.5)
3.95
(max. 183.5)
4.35
3.95
max. 7.22
max. 7.22
5.23 X2
(132.9) Z
6.83(173.5)
7.34 (186.4)
PS MH
7.18 (182.4)
1.2(30.5)
T1
5.91(150)
(25.1)2)
(YST)
(PS)
0.99
(Ø152.4 -0.063)
DIA5.998
(G)
DIA6.000
(161.6)
6.36
0
1.77
(45)
(T 1)
0.59(15)
(116.3)
5.2 (132)
3.86
(98)
0.83
(21)
4.58
0.71
(18)
Flange D6 T2
(S)
SAE J744
(T1) 5.02(127.5) G S YST
6.46 (164.2)2) X
6.36
(161.6)
(YST, G) 7.89 (200.5)
9
(PS) 8.07 (205.1) (228.6)
(S) 10.18 (258.5)
12.70 (322.7)3)
MB
X1 B, A B
(B, A)
(109.2)
0.2 (5)
3.74
(95)
(85.5)
S
4.3
3.27
3.37
(83)
2.91
(109.2)
(74)
(85.5)
3.37
(83)
3.27
4.3
(S)
(123.5)
MH
(PS,YST, G) 4.86
A M A T2 5.69
X2 PS, YST, G (144.5)
6.83
(173.5)
9.95
(252.7)
Detail view of mounting
flange C6 (optional)
0.59 (15) 4-hole
0.71 (18) 2-hole Detail X
0.5
(12.7)
0.98
(27.8)
1.09
(25)
(Ø127-0.063)
DIA4.998
DIA5.000
2.25
0
(57.2)
Flange C6
SAE J744
1) ForSAE working ports A and B, 45° right (viewed on drive shaft), the 3) Valid for version with standard internal gear pump,
complete case and thus the dimensions are mirrored. overall length without boost pump see through drive, page 41.
2) Center of gravity
5/8-11UNC-2B2)
1.42 1.42 (36)
(36)
0.47 0.45
(12) (11.4)
DIA3.98 (Ø101)
DIA3.98 (Ø101)
DIA2.17
DIA2.17
(Ø55)
(Ø55)
2.17 (55) 2.60 (66)
2.95 (75) 3.46 (88)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat root, 6) Depending on installation position, T1 or T2 must be connected (see also
side fit, tolerance class 5 installation instructions on page 60).
2) Thread according to ASME B1.1 7) The countersink can be deeper than as specified in the standard.
3) Depending on the application, momentary pressure peaks can oc- cur. 8) Optional, see page 51
Keep this in mind when selecting measuring devices and fit- tings. 9) For the maximum utilization of pressure, only grade 8 screws and hardened
4) Only dimensions according to SAE J518. washers are to be used to tighten the SAE flange shells.
5) Plugged for external boost pressure supply. 10) O = Must be connected (plugged when delivered) X =
▼oH
po
Wrt–
ioP
narl control, hydraulic, mechanical servo ▼ EZ – Two-point control, electric
0.31
1.06
(8)
(27)
DIA0.31 (Ø8)
(150)
5.91
(197.8)
7.79
Version with
neutral position
switch, HW8
3.95
(100.4)(100.4)
0.79
(20)
3.95
2.68
(68)
10.17
(258.4)
(151.5)
5.96
(109.2) (109.2)
4.3 4.3
DA control valve
▼ DA..1 – fixed setting
10.28 (261)
10.25 (260.4)
(150)
5.91
0.20
(5)
(100.4) (100.4)
3.95
(max. 183.5)
3.95
max. 7.22
5.73(145.5) 6.48(164.5)
(T2) 3.94 5.37(136.4) (T1)
(100)
10.38 (263.6) 0.04
0.79 (20) (1.0)2)
T1 X1 R X2
0.5
(12.7)
PS MH
8.17 (207.4)
8.01 (203.4)
1.22(31)
T1
6.69(170)
(28.9)2)
(YST)
(PS)
1.14
(G)
0.83
(Ø152.4 -0.063)
(21)
DIA5.998
DIA6.000
0
(161.6)
6.36
1.97
(50)
0.79(20)
(18)(T )
(108)
(131.9)
1
4.25
5.19
0.71
Flange D6 T2
(S)
0.83
(21)
SAE J744
(T1) 4.73(120.2) G S YST 6.36
2) X (161.6)
6.85 (173.9)
(G, YST, PS) 8.31 (211.2) 9 (228.6)
(S) 11.07 (281.2) max. 6.16
(max. 156.5)
13.55 (344.2)3)
MB
X1 B, A B
(B, A)
(109.2)
0.2 (5)
S
(102)
(88.5)
4.02
(98)
3.86
4.3
3.48
2.91
(88.5)
(74)
(S)
(109.2)
3.86
3.48
5.37
(136.4)
4.3
(98)
MH
A MA T2
(PS,YST, G)
Detail X
(31.8)
1.26
1.25
(32)
2.63
(66.7)
1) ForSAE working ports A and B, 45° right (viewed on drive shaft), the 3) Valid for version without boost pump and for standard internal gear pump,
complete case and thus the dimensions are mirrored. overall length with large internal gear pump, see through drive, page 41.
2) Center of gravity
5/8-11UNC-2B2)
5/8-11UNC-2B2) 1.42 1.42
(36) (36)
0.47 0.47
(12) (12)
DIA4.37 (Ø111)
DIA4.37 (Ø111)
DIA2.36
DIA2.36
(Ø60)
(Ø60)
2.17 (55) 2.60 (66)
2.95 (75) 3.46 (88)
3.15 (80)
2)
3/4-10UNC-2B
1.65
(42)
0.49
(15)
DIA4.37 (Ø111)
DIA2.36
(Ø60)
2.60 (66)
3.46 (88)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat root, 2) Thread according to ASME B1.1
side fit, tolerance class 5
3) Depending on the application, momentary pressure peaks can occur. 7) The countersink can be deeper than as specified in the standard.
Keep this in mind when selecting measuring devices and fittings. 8) Optional,see page 51
4) Only dimensions according to SAE J518. 9) For the maximum utilization of pressure, only grade 8 screws and hardened
5) Plugged for external boost pressure supply. washers are to be used to tighten the SAE flange shells.
6) Depending on installation position, T1 or T2 must be connected (see 10) O = Must be connected (plugged when delivered) X =
0.31
1.06
(8)
(27)
(170)
6.69
DIA0.31
(218.7)
(Ø8)
8.61
Y1 Version with
neutral position
(41.2)
1.62
switch, HW8
0.79
(20)
(41.2)
1.62
2.68
(68)
Y2
(170) (100.4)(100.4)
3.86
(98)
(265.6)
8.01
X2 YHT
X1
1.57
(40)
3.86
(98)
10.38
(263.6)
7.04
(178.7)
(171.5)
7.63(193.7)
6.75
(109.2)(109.2)
4.3 4.3
5.73(145.5) 6.48(164.5)
(T2) 3.94 5.37(136.4) (T1)
(100)
11.16 0.08
0.79 (20) (283.4) (2.0)2)
X1 R X2
0.63 T1
(15.9)
PS MH
8.17 (207.4)
8.01 (203.4)
6.69 (170)
1.22(31)
(26.7)2)
(YST)
(G)
1.05
(PS)
T1
(Ø165.1 -0.063)
DIA6.498
(224.5)
DIA6.500
0
8.84
(18) (T )
0.79(20)
1.97
(50)
1
(138.1)
(108)
4.25
5.44
0.71
Flange E4 T2
(S)
SAE J744
0.83
(21)
(T1) 5.51(140) G S YST 8.84 (224.5)
X
6.98 (177.3)2) max. 6.16
(G, YST, PS) (max. 156.5)
9.09 (231)
(S) 11.85 (301)
14.46 (367.3)3)
MB
X1 B, A B
(B, A)
0.2 (5)
(109.2)
S
(102)
(88.5)
4.02
4.3
(98)
3.86
3.48
2.91
(S)
(74)
(88.5)
(109.2)
5.37
3.48
(136.4)
(98)
3.86
4.3
MH
A M A T2
(PS,YST, G)
6.14
7.81 X2 PS, YST, G (156)
(198.5) 11.69
(297)
Detail view of
mounting flange D6 (optional)
0.79
(20)
0.5
(12.7)
Detail X
(Ø152.4-0.063)
DIA5.998
DIA6.000
0
(31.8)
1.25
1.26
(32)
2.63
Flange D6 SAE
J744 (66.7)
1) ForSAE working ports A and B, 45° right (viewed on drive shaft), the 3) Valid
for version with standard internal gear pump,
complete case and thus the dimensions are mirrored. overall length without boost pump and with large internal gear pump,
2) Center of gravity see through drive, page 41.
3/4-10UNC-2B2)
5/8-11UNC-2B2) 1.42 1.65
(36) (42)
0.47 0.49
(12) (15)
DIA4.37 (Ø111)
DIA4.37 (Ø111)
DIA2.36
DIA2.36
(Ø60)
(Ø60)
2.17 (55) 2.60 (66)
2.95 (75) 3.46 (88)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat root, 6) Depending on installation position, T1 or T2 must be connected (see also
side fit, tolerance class 5 installation instructions on page 60).
2) Thread according to ASME B1.1 7) The countersink can be deeper than as specified in the standard.
3) Depending on the application, momentary pressure peaks can oc- cur. 8) Optional, see page 51
Keep this in mind when selecting measuring devices and fit- tings. 9) For the maximum utilization of pressure, only grade 8 screws and hardened
4) Only dimensions according to SAE J518. washers are to be used to tighten the SAE flange shells.
5) Plugged for external boost pressure supply. 10) O = Must be connected (plugged when delivered) X =
2.48(63) 63 0.35(9)
9.71
(246.7) 1.97(50)
0.31
1.06
(8)
(27)
DIA0.31
(170)
6.69
(217.8)
(Ø8)
8.58
Y1
Version with
(41.2)
1.62
neutral position
switch, HW8
0.79
(20)
(41.2)
1.62
2.68
(68)
Y2
(170) (100.4)(100.4)
3.86
(98)
11.24
3.95 3.95
(203.4)
(285.4)
8.01
X2 YHT
6.69
X1
11.16
(283.4)
(171.5)
6.75
7.81(198.5)
8.41(213.5)
(109.2) (109.2)
4.3 4.3
6.69(170) 7.34(186.5)
(T2) 4.45 6.04(153.4) (T1)
(113)
12 0.08
(304.9) (2.0)2)
0.87 (22) X1 R X2
T1
0.63
(15.9)
PS MH
9.43 (239.4)
9.27 (235.4)
7.85 (199.5)
2.05(52)
0.79(20)
0.59(15)
1.38(35)
(31)2)
1.22
T1
(Ø165.1-0.063)
DIA6.498
DIA6.500
(224.5)
0
8.84
(PS)
(T1)
(YST)
(122)
(152.2)
(G)
4.8
5.99
Flange E4 T2
(S)
SAE J744
0.83
(21)
(T1) 5.75(146) G S YSt 8.84 (224.5)
X
7.44 (189)2) max. 6.75
Y
(max. 171.5)
(G, YST) 9.41 (239)
(PS) 9.72 (247)
(S) 12.76 (324)
15.26 (387.6)3)
MB
X1 B, A B
(B, A)
(112.5)
4.43
4.37
(111)
(106)
4.17
S
(109.2) (109.2)
4.3
(86.5)
(112.5)
3.41
(106)
4.17
4.43
(153.4)
4.3
6.04
MH
(PS,YST, G)
A M A T2
8.27 X2 YST, G PS 6.57(167)
(210)
12.13
(308)
Detail X Detail Y
Port A, B Port S
1.5 1.5
(36.5)
1.44
(35.7)
1.41
(38) (38)
3.13 2.75
(79.4) (69.9)
1) ForSAE working ports A and B, 45° right (viewed on drive shaft), the 3) Valid for version without boost pump and for standard internal gear pump,
complete case and thus the dimensions are mirrored. overall length with large internal gear pump, see through drive, page 41.
2) Center of gravity
3/4-10UNC-2B2)
5/8-11UNC-2B2)
1.42 1.65
(36) (42)
0.47 0.49
(12) (15)
DIA4.76 (Ø121)
DIA4.76 (Ø121)
DIA2.56
DIA2.56
(Ø65)
2.60 (66) (Ø65) 2.60 (66)
3.46 (88) 3.46 (88)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat root, 6) Depending on installation position, T1 or T2 must be connected (see also
side fit, tolerance class 5 installation instructions on page 60).
2) Thread according to ASME B1.1 7) The countersink can be deeper than as specified in the standard.
3) Depending on the application, momentary pressure peaks can oc- cur. 8) Optional, see page 51
Keep this in mind when selecting measuring devices and fit- tings. 9) For the maximum utilization of pressure, only grade 8 screws and hardened
4) Only dimensions according to SAE J518. washers are to be used to tighten the SAE flange shells.
5) Plugged for external boost pressure supply. 10) O = Must be connected (plugged when delivered) X =
2.48(63) 0.35(9)
3.95 1.97(50)
0.31
(266.2)
(8)
1.06
(27)
DIA0.31
(199.5)
(247.3)
7.85
(Ø8)
9.74
Y1
Version with
(41.2)
1.62
neutral position
switch, HW8
0.79
(20)
(41.2)
1.62
2.68
(68)
Y2
12.0
(304.9)
(199.5)
7.85
(100.4)(100.4)
3.95 3.95
9.27 (235.4)
9.43 (239.4)
7.85 (199.5)
1.38(35)
0.79(20)
0.59(15)
(PS)
(32)2)
1.26
T1
(Ø165.1-0.063)
DIA6.498
DIA6.500
(224.5)
0
8.84
(YST)
2.05
(52)
(122)
(152.2)
(T1)
4.8
(G)
5.99
Flange E4 T2
(S)
SAE J744
0.83
(21)
(T1) 6.57(166.9) G S YST X 8.84 (224.5)
8.46 (215) 2) max. 6.75
Y (max. 171.5)
(G, YST) 10.23 (259.9)
(PS) 10.55 (267.9)
(S) 13.58 (344.9)
16.24 (412.6)3)
MB
X1 B, A B
(B, A)
(112.5)
S
4.43
4.37
(111)
(106)
4.17
(109.2) (109.2)
4.3
(86.5)
3.41
(106)
(112.5)
4.17
4.3
4.43
(153.4)
6.04
MH
(PS,YST, G)
Detail X Detail Y
(Port A, B) (Port S)
(36.5)
(35.7)
1.44
1.41
1.5 1.5
(38) (38)
3.13 2.75
(79.4) (69.9)
1) ForSAE working ports A and B, 45° right (viewed on drive shaft), the 3) Valid for version with standard internal gear pump,
complete case and thus the dimensions are mirrored. overall length without boost pump see through drive, page 41.
2) Center of gravity
3/4-10UNC-2B2)
1.42 1.65
(36) (42)
0.47 0.49
(12) (15)
DIA4.76 (Ø121)
DIA4.76 (ø121)
DIA2.56
DIA2.56
(Ø65)
(ø65)
2.60 (66) 2.60 (66)
3.46 (88) 3.46 (88)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat root, 6) Depending on installation position, T1 or T2 must be connected (see also
side fit, tolerance class 5 installation instructions on page 60).
2) Thread according to ASME B1.1 7) The countersink can be deeper than as specified in the standard.
3) Depending on the application, momentary pressure peaks can oc- cur. 8) Optional, see page 51
Keep this in mind when selecting measuring devices and fit- tings. 9) For the maximum utilization of pressure, only grade 8 screws and hardened
4) Only dimensions according to SAE J518. washers are to be used to tighten the SAE flange shells.
5) Plugged for external boost pressure supply. 10) O = Must be connected (plugged when delivered) X =
2.48(63) 0.35(9)
11.30 (287.1) 1.97(50)
0.31
(8)
1.06
(27)
(199.5)
7.85
DIA0.31
(247.3)
9.74
(Ø8)
Y1
Version with
(41.2)
1.62
neutral position
switch, HW8
0.79
(20)
(41.2)
1.62
2.68
(68)
Y2
12.8
(325.7)
(199.5)
7.85
(100.4)(100.4)
3.95 3.95
▼ Without through drive, without boost pump, with standard internal gear pump or with large internal gear pump
NG M0 M1 M2
110 12.37 12.53 12.70
(314.3) (318.3) (322.7)
125 12.37 12.70 –
(314.3) (322.7) –
145 13.55 13.55 13.68
(344.2) (344.2) (347.5)
175 14.32 14.46 14.s57
(363.8) (367.3) (370.1)
210 15.26 15.26 15.46
M0 − without boost pump
(387.6) (387.6) (392.7)
M1 − with standard internal gear pump M2 −
280 16.04 16.24 –
with large internal gear pump
(407.3) (412.6) –
▼ 82-2
NG M1 M2 M3 M4 M5 M65)
M6 110 12.77 12.93 0.35 0.37 1.36 3/8-16UNC-2B;
O-ring 4)
(324.3) (328.3) (9) (9.4) (34.6) 0.51 (13) deep
▼ 101-2
NG M1 M2 M3 M4 M5 M65)
M6
O-ring4) 110 12.89 13.04 0.39 0.43 1.93 1/2-13UNC-2B;
(327.3) (331.2) (10) (10.9) (48.9) 0.63 (16) deep
0004
DIA4 .0 +0. 0014 125 13.04 − 0.39 0.43 1.89
Ø 10 1.6 0.035
+ 0.010 (331.2) −
+0.
+
3.5
▼ 127-2, 127-2/4
NG M1 M2 M3 M4 M5 M65) 2-hole
C4 4.51 110 13.12 13.28 0.55 0.67 2.29 5/8-11UNC-2B;
(114.5) M7 0.83(21) deep
(333.3) (337.3) (14) (16.9) (54.9)
M6 O-ring4) 125 On request 0.55 0.43 2.36 On request
(14) (10.9) (59.9)
)
▼ 152-4
NG M1 M2 M3 M4 M5 M65)
O-ring4)
145 14.02 14.15 0.55 0.39 2.93 3/4-10UNC-2B;
M6
(356.2) (359.5) (14) (10) (74.4) 0.87 (22) deep
+0.035
+0.0014
6.36 D4 M3
(161.6)
M4
M5
M1 − with standard internal gear pump M2 −
with large internal gear pump
(to mounting flange)
▼ 165-4
NG M1 M2 M3 M4 M5 M65)
O-ring4)
175 15.00 15.11 0.67 0.76 3.07 3/4-10UNC-2B;
(381) (383.8) (17) (19.4) (77.9) 0.87 (22) deep
+0.035
+0.0014
210 16.04 16.24 On request
DIA6.5+0.0004
Ø165.1+0.010
(224.5)
8.84
(407.3) (412.4)
280 17.61 – On request
(447.3) –
M3
M6
8.84 M4
(224.5)
M5
M1 − with standard internal gear pump M2 −
with large internal gear pump
(to mounting flange)
Notice
The mounting options listed only apply for drive shaft versions
with undercut. Please contact us for drive shafts without
undercut.
1) Availability
of the individual sizes, see type code on page 4.
2) BoschRexroth recommends special versions of the gear pumps. Please
contact us.
The two high-pressure relief valves protect the hydrostatic High-pressure relief valve without pressure cut-off
transmission (pump and motor) from overloading. They limit the
maximum pressure in the respective high-pressure line and serve ▼ Example
simultaneously as boost valves. Working Boost Differential
High-pressure relief valves are not working valves and are pressure pressure pressure
only suitable for pressure peaks or high rates of pressure pA,B pSp ∆pHD
change. 6500 psi ‒ 290 psi = 6250 psi
(450 bar) (20 bar) (430 bar)
Setting ranges
▼ Setting diagram
High-pressure reliefvalve Differential pressure setting
A and B ∆pHD pmax
Preferred values 5800 psi (400 bar) ≥ 435 psi
≥ (30 bar)
5950 psi (410 bar)
Safety
6100 psi (420 bar)
Differential pressure
pHD HD valve setting
6250 psi (430 bar)
at port A, B
drive design
6400 psi (440 bar)
6500 psi (450 bar)
Ap
6650 psi (460 bar)
pSp
6800 psi (470 bar)
Optional values 4350 psi (300 bar)
pSp
Boost pressure
4650 psi (320 bar)
qv1 qv max
4950 psi (340 bar)
(п = 1000 rpm) (n = nmax)
5200 psi (360 bar)
5500 psi (380 bar)
High-pressure relief valve with pressure cut-off
Settings on high-pressure relief valve A and B
Differential pressure setting ΔpHD = ... psi ▼ Example
Cracking pressure of the HD valve (at qV 1) (pmax pmax = ... psi
Working Boost Safety Differential
= ΔpHD + pSp)
pressure pressure pressure
▶ The valve settings are made at n = 1000 rpm and at Vg max (qv pA,B pSp ∆pHD
1). There may be deviations in the cracking pressures with 6500 psi 290 psi 435 psi 6645 psi
‒ + =
other operating parameters. (450 bar) (20 bar) (30 bar) (460 bar)
▶ When ordering, state differential pressure setting in
plain text. ▼ Setting diagram
pmax
▼ Circuit diagram ≥ 435 psi
≥ (30 bar)
R YHT
X1 X2 Safety Setting value
Differential pressure
pHD HD valve setting
pressure cut-off
T1 MH PS YST MB B
Working pressure pA, B
drive design
at port A, B
Ap
pSp
Boost pressure
qv1 qv max
(п = 1000 rpm) (n = nmax)
T2 G S MA A
The pressure cut-off is a pressure control which, after reaching A connection between the two high-pressure channels A and
the set pressure, adjusts the displacement of the pump back to Vg B can be established using the bypass valve (e.g. for
min. machine towing).
This valve prevents the operation of the high-pressure relief valves
when accelerating or decelerating. Towing speed
The high-pressure relief valves protect against the pressure peaks The maximum towing speed is dependent on the gear ratio in the
which occur during fast swiveling of the swashplate and limit the vehicle and must be calculated by the vehicle manu- facturer.
maximum pressure in the system. The corresponding flow of qV = 7.9 gpm (= 30 l/min) may not be
The setting range of the pressure cut-off may be anywhere within exceeded.
the entire working pressure range. However, it must be set 435 psi
(30 bar) lower than the setting value of the high-pressure relief Towing distance
valves (see setting diagram, The vehicle may only be towed out of the immediate danger zone.
page 47).
Please state the setting value of the pressure cut-off in plain
text when ordering.
Bypass
a b
Pressure cut-off
X1 X2
T1 MH PS YST MB B
T2 G S MA A
Neutral valve
N3
The return swivel times can be specifically and precisely adapted
to the respective customer application. A second capability for
deactivation and therefore making the pump torque-free is
therefore realized when the neutral valve is used in safety-critical
N4 X1 R
applications.
N6
N5
Technical data
Voltage 12 V (±20%) 24 V (±20%)
N8
N7
Neutral position Vg = 0 de-energized de-energized
Position Vg max Current Current
switched on switched on
N9 X2
Nominal resistance (at 68 °F (20 °C)) 5.5 Ω 21.7 Ω
Nominal power 26.2 W 26.5 W
Minimum active current required 1.2 A 0.6 A
NG 110 125 145 175 210 280
Duty cycle 100% 100%
N1 7.81 7.81 8.02 8.80 9.37 10.19
Type of protection: see connector version page 57
(198.4) (198.4) (203.6) (223.4) (237.9) (258.8)
N2 3.96 3.96 4.17 4.95 5.52 6.34
▼ Circuit diagram
(100.7) (100.7) (105.9) (125.7) (140.2) (161.1)
R
N3 9.05 9.05 9.86 9.86 11.14 11.14
(229.8) (229.8) (250.5) (250.5) (283) (283)
X2 N4 6.83 6.83 7.04 7.81 8.27 9.09
(173.5) (173.5) (178.7) (198.5) (210) (230.9)
a b
N5 4.04 4.04 4.04 4.04 4.04 4.04
(102.5) (102.5) (102.5) (102.5) (102.5) (102.5)
X1 N6 3.27 3.27 3.86 3.86 4.43 4.43
(83) (83) (98) (98) (112.5) (112.5)
T1 MH PS YST MB B
N7 3.8 3.8 3.8 3.8 3.8 3.8
(96.5) (96.5) (96.5) (96.5) (96.5) (96.5)
N8 3.11 3.11 3.11 3.11 3.11 3.11
(79) (79) (79) (79) (79) (79)
N9 6.79 6.79 7.0 7.78 8.35 9.17
(172.5) (172.5) (177.7) (197.5) (212) (232.9)
T2 G S MA A
The mechanical stroke limiter is an auxiliary function allow- ing the ▼ Circuit diagram
M1
M2
M3
T2 G S MA A
M3
NG M1 M2 M3
110 6.05 1.09 6.19
(153.6) (27.7) (157.3)
125 6.05 1.09 6.19
(153.6) (27.7) (157.3)
145 6.10 1.33 6.70
(155) (33.8) (170.1)
175 6.88 1.33 6.70
(174.8) (33.8) (170.1)
210 7.24 1.50 7.86
(183.9) (38.1) (199.6)
280 8.06 1.50 7.86
(204.7) (38.1) (199.6)
X1 X2
X3 X4
T1 MH PS YST MB B
X3
T3 T3
X4
NG T1 T2 T3 T2 G S MA A
110 6.37 0.86 5.04
(161.8) (21.8) (128)
125 6.37 0.86 5.04
(161.8) (21.8) (128)
145 6.49 1.04 5.59
(164.9) (26.4) (142)
175 7.27 1.04 5.59
(184.7) (26.4) (142)
210 7.70 1.20 6.54
(195.7) (30.6) (166)
280 8.53 1.20 6.54
(216.6) (30.6) (166)
Filtration in the boost pump suction line Filtration in the boost pump pressure line
Version S Version D
Filter version Suction filter Ports for external boost circuit filtration
Recommendation With contamination indicator, Ports
with cold start valve
Boost pressure inlet Port Fa
Recommended flow resistance at filter element
Boost pressure outlet Port Fe
At ν = 140 SUS, n = nmax Δp ≤ 1.5 psi Filter version Boost pressure filter
(30 mm2/s, n = nmax) (≤ 0.1 bar)
Recommendation With contamination indicator,
At ν = 4600 SUS, n = nmax Δp ≤ 4.5 psi with cold start valve
(1000 mm2/s, n = nmax) (≤ 0.3 bar)
Filter arrangement Separate in the pressure line (inline
Pressure at suction port S filter)
Continuous pS min (ν ≤ 140 SUS) ≥ 12 psi absolute Permissible flow resistance at filter element1)
(ν ≤ 30 mm2/s) (≥ 0.8 bar absolute)
At ν = 140 SUS Δp ≤ 15 psi (≤
Short-term, at a cold start ≥ 7.5 psi absolute (30 mm2/s) 1 bar)
(t < 3 min) (≥ 0.5 bar absolute) For cold start Δp ≤ 45 psi
Maximum pressure pS max ≤ 75 psi absolute (≤ (≤ 3 bar)
5 bar absolute)
Notice
Use of version S is preferred.
▶ Filters with a bypass notrecommended. Please con- tact us
The suction filter is not included in the scope of delivery.
for applications with a bypass.
▼ Circuit diagram ▶ On versions with HT control (with pilot pressure not from a
boost circuit) a filter must be used that fulfills the requirement
R YHT
X1 X2 with regard to filtration of the hydrau- lic fluid (see page 7).
T1 MH PS YST MB B
The boost pressure filter is not included in the scope of
delivery.
▼ Circuit diagram
R
a b
X1 X2
T1 MH PS YST Fa Fe MB B
T2 G S MA A
T2 G S MA A
Notice
Bosch Rexroth has a comprehensive filter range. An inline filter
such as the 110 LEN (see data sheet 51448) is suitable for
charge pressure filtration. Further informa- tions can also be
found at www.boschrexroth.com/filter.
1) Valid for entire speed range nmin – nmax
X1 X2
NG110, 125 NG210, 280
145(10)
Differential pressure Ap
T1 MH PS YST MB B
NG145, 175
15(1)
NG145, 175
NG110, 125
NG210, 280
1.5(0.1)
2.6 7.9 13.2 26.4 52.6
(10) (30) (50) (100) (200) S MA A
T2 G
Flow [gpm (l/min)]
▼ Circuit diagram
a b
X1 X2
T1 MH PS YST MB B
1) Ifusing the filter versions F and B, make sure that a hydraulic fluid with a
minimum electrical conductance of 300 pS/m is used. Please contact us if
T2 G S MA A this value cannot be observed.
Version E
This variant should be used in versions without integrated boost
pump (U).
Port S is plugged.
The boost pressure supply comes from port G.
The filter should be installed separately on port G before the
boost pressure supply.
To ensure the functional reliability, maintain the required
cleanliness level for the boost fluid fed in at port G
(see page 7).
▼ Circuit diagram
a b
X1 X2
T1 MH PS YST Fa MB B
T2 G MA A
▼ Version D
Ports for external boost circuit filtration NG F1 F2 F3 F4 F5 F6 F7
110 3.01 9.04 0.87 4.76 10.41 1.46 0.55
(76.5) (229.5) (22) (121) (264.5) (37) (14)
▼ Version F
Attachment filter without contamination indicator
F1 Detail A
rotated through 90°
A
F3
F2
▼ Version B
Attachment filter with cold start valve and electric contami- nation
indicator
Detail Arotated
F1
through 90°
F2
The swivel angle sensor is used to detect the swivel angle of axial Dimensions
piston units and thus the displacement using a Hall-effect A
based sensor IC. The determined measurement value is
converted into an analog signal.
Please contact us if the swivel angle sensor is used for
B
control.
Characteristics
Supply voltage Ub 10 to 30 V DC
Y
Output voltage Ua 1V 2.5 V 4V
(Vg max) (Vg 0) (Vg max)
Reverse polarity protection Short-circuit resistant
C
EMC resistance Details on request
Operating temperature range -40 °F to +240 °F
(-40 °C to +115 °C)
Vibration resistance 322 ft/s 2 (10 g) /
sinusoidal vibration EN 60068-2-6 5 to 2000 Hz
Shock resistance: 805 ft/s2 (25 g) Detail Y
continuous shock IEC 68-2-29 Connector DT04-3P-EP04
Salt spray resistance (DIN 50 021-SS) 96 h
Type of protection with installed IP67 – DIN EN 60529
mating connector IP69K – DIN 40050-9
Supply voltage Ub Ground
Housing material Plastic
Output voltage Ua
Output voltage NG A B C
110 2.03 (51.5) 5.86 (148.8) 1.46 (37)
Direction of Flow Working Output voltage
rotation1) direction pressure at Vg 0 125 2.03 (51.5) 5.86 (148.8) 1.46 (37)
a 1 wedge W3S
b
2 sockets 0462-201-16141
X1 X2 The mating connector is not included in the scope of delivery.
T1 α U MH PS YST MB B
This can be supplied by Bosch Rexroth on request (material
number R902603524).
Notice
It is not possible to retrofit existing units with a swivel angle
sensor.
T2 G S MA A
DEUTSCH DT04-2P-EP04
Molded, 2-pin, without bidirectional suppressor diode
(standard).
The following type of protection ensues with an installed mating
connector:
▶ IP67 (DIN EN 60529) and
▶ IP69K (DIN 40050-9)
▼ Switching symbol
Consisting of DT designation
1 housing DT06-2S-EP04
1 wedge W2S
2 sockets 0462-201-16141
Notice
▶ If necessary, you can change the position of the
connector by turning the solenoid.
▶ The procedure is defined in the instruction manual.
Speed sensor
Dimensions
A1
A2
Notice
It is not possible to retrofit existing units with a speed sensor.
x2
Coupling hub x1
Ød1
Ød4
Ød2
Ød3
x3
NG Mounting ⌀ d1 ⌀ d2 min ⌀ d3 ⌀ d4 x1 x2 x3
flange
0 +0.035
110 127-2/4 2.17 2.93 3.976±0.004 5.00 −0.002 0.236 0.5–0.02 0.315 −0.024
0 )
(55) (74.4) (101±0.1) (152.4 −0.063 (6.0) (12.7–0.5) −0.6)
(8 +0.9
0 +0.035
125 127-2/4 2.17 2.93 3.976±0.004 5.00 −0.002 0.236 0.5–0.02 0.315 −0.024
0 )
(55) (74.4) (101±0.1) (127 −0.063 (6.0) (12.7–0.5) −0.6)
(8 +0.9
0 +0.035
152-2/4 2.17 2.93 3.976±0.004 6.00 −0.002 0.236 0.5–0.02 0.315 −0.024
0 )
(55) (74.4) (101±0.1) (152.4 −0.063 (6.0) (12.7–0.5) −0.6)
(8 +0.9
0 +0.035
145 152-2/4 2.36 3.32 4.370±0.004 6.00 −0.002 0.291 0.5–0.02 0.315 −0.024
0 )
(60) (84.4) (111±0.1) (152.4 −0.063 (7.4) (12.7–0.5) −0.6)
(8 +0.9
0 +0.035
175 152-2/4 2.36 3.32 4.370±0.004 6.00 −0.002 0.276 0.5–0.02 0.315 −0.024
0 )
(60) (84.4) (111±0.1) (152.4 −0.063 (7.0) (12.7–0.5) −0.6)
(8 +0.9
0 +0.035
165-4 2.36 3.32 4.370±0.004 6.50 −0.002 0.276 0.63–0.02 0.315 −0.024
0 )
(60) (84.4) (111±0.1) (165.1 −0.063 (7.0) (15.9–0.5) −0.6)
(8 +0.9
0 +0.035
210 165-4 2.56 3.72 4.764±0.004 6.50 −0.002 0.22 0.63–0.02 0.315 −0.024
0 )
(65) (94.4) (121±0.1) (165.1 −0.063 (5.5) (15.9–0.5) −0.6)
(8 +0.9
0 +0.035
280 165-4 2.56 3.72 4.764±0.004 6.50 −0.002 0.276 0.63–0.02 0.315 −0.024
0 )
(65) (94.4) (121±0.1) (165.1 −0.063 (7.0) (15.9–0.5) −0.6)
(8+0.9
Installation instructions
General Notice
The axial piston unit must be filled with hydraulic fluid and air bled ▶ If filling the stroking chambers via X1 to X4 is not possible in
during commissioning and operation. This must also be the final installation position, then this must take place
observed following a longer standstill as the axial piston unit may before installation, e.g. in installation position 2.
empty via the hydraulic lines. ▶ To prevent unexpected actuation and damage, the
Particularly in the installation position “drive shaft upwards”, stroking chambers must be air bled via the ports X1, X2, or
filling and air bleeding must be carried out com- pletely as there is, X3, X4 depending on the installation position.
for example, a danger of dry running. ▶ In certain installation positions, an influence on the control
The leakage in the housing area must be directed to the or closed loop control can be expected. Grav- ity, dead
reservoir via the highest drain port (T1, T2). weight and case pressure can cause minor shifts in control
For combination pumps, the leakage must be drained off at each characteristic curves and changes in response time.
pump.
If a shared drain line is used for several units, make sure that the
respective case pressure is not exceeded. The shared drain line
must be dimensioned to ensure that the maximum permissible Below-reservoir installation (standard)
case pressure of all connected units is not exceeded in any Below-reservoir installation means that the axial piston unit is
operating conditions, specifically on cold start. If this is not installed outside of the reservoir and below the minimum fluid level
possible, separate drain lines must
of the reservoir.
be laid if necessary.
Installation Air bleeding Air bleeding Filling
To achieve favorable noise values, decouple all connecting lines position the housing the stroking
using elastic elements and avoid above-reservoir chamber
installation. 1 R X1, X2 S + T1 + X1 + X2
Under all operating conditions, the suction line and drain line
SB
must flow into the reservoir below the minimum fluid level. The
ht min
permissible suction height hS results from the overall loss of
pressure. However, it must not be higher than hS max = 31.5 in hmin
(800 mm).
R X2, X1
The suction pressure at port S must also not fall below the
T1
minimum value of 12 psi (0.8 bar) absolute during opera- tion (cold
start 7.5 psi (0.5 bar) absolute).
Installation position S
See the following examples 1 to 12.
Further installation positions are available upon request. 2 − − S + T2
Recommended installation position: 1 and 2. SB
ht min
hmin
S T2
F1 X2, X1 R
4 R1 X3, X4 S + T1 + X3 + X4
SB F2
ht min
hmin
T1 S
T1
hS max SB
R1
ht min
hmin
S X4, X3
8 F2 (S) + F1 (T2) − F2 (S) + F1 (T2)
5 − X3 S + T2 + X3
F1
SB F2
T2
S
ht min
hmin
T2 X3
S SB
hS max
ht min
hmin
T1
SB
S
ht min
T2
hmin
F1 Notice
Ports F1 and F2 are part of the external piping and must be
T2 X3
provided on the customer side to make filling and air bleeding
F2
S easier.
hS max SB
T1 h
t min
hmin
F2 S
SB hS max T2
ht min
hmin
▶ The pump A4VG is designed to be used in closed circuit. ▶ For drives that are operated for a long period with con- stant
▶ The project planning, installation and commissioning of the rotational speed, the natural frequency of the hydraulic
axial piston unit requires the involvement of quali- fied skilled system can be excited by the excitation fre- quency of the
personnel. pump (rotational speed frequency ×9). This can be prevented
▶ Before using the axial piston unit, please read the with suitably designed hydraulic lines.
corresponding instruction manual completely and ▶ Please note the details regarding the tightening torques of port
thoroughly. If necessary, these can be requested from Bosch threads and other threaded joints in the instruc- tion manual.
Rexroth. ▶ Working ports:
▶ Before finalizing your design, please request a binding – The ports and fastening threads are designed for the
installation drawing. specified maximum pressure. The machine or system
▶ The specified data and notes contained herein must be manufacturer must ensure that the connecting ele- ments
observed. and lines correspond to the specified applica- tion
▶ Depending on the operating conditions of the axial piston conditions (pressure, flow, hydraulic fluid, tem- perature)
unit (working pressure, fluid temperature), the with the necessary safety factors.
characteristic curve may shift. – The working ports and function ports are only
▶ Preservation: Our axial piston units are supplied as standard intended to accommodate hydraulic lines.
with preservative protection for a maximum of 12 months. If
longer preservative protection is required (maximum 24
months), please specify this in plain text when placing your
order. The preservation periods apply under optimal storage
conditions, details of which can be found in the data sheet
90312 or the instruction manual.
▶ Not all versions of the product are approved for use in a safety
function according to ISO 13849. Please consult the
responsible contact person at Bosch Rexroth if you require
reliability parameters (e.g. MTTFD) for functional safety.
▶ Depending on the type of control used, electromagnetic effects
can be produced when using solenoids. Applying the
recommended direct voltage signal (DC) to sole- noids does
not create electromagnetic interference (EMI) nor is the
solenoid affected by EMI. Electromag- netic interference (EMI)
potential exists when operating and controlling a solenoid with
a modulated direct voltage signal (e.g. PWM signal).
Appropriate testing and measures should be taken by the
machine manufacturer to ensure other components or
operators (e.g. with pacemaker) are not affected by this
potential.
▶ The pressure cut-off is not a safeguard against pressure
overload. Be sure to add a pressure relief valve to the
hydraulic system.
▶ With dynamic power flow (switch of pumps to operation as a
motor) a maximum of 95% Vg max is permissible. We
recommend configuring the software accordingly.
Safety instructions
Bosch Rexroth Corporation © Bosch Rexroth AG 2017. All rights reserved, also regarding any disposal, exploitation,
8 Southchase Court reproduction, editing, distribution, as well as in the event of applications for industrial
Fountain Inn, SC 29644-9018, USA property rights. The data specified within only serves to describe the product. No
Telephone (864) 967-2777 statements concerning a certain condition or suitability for a certain application can be
Facsimile (864) 967-8900 derived from our information.
www.boschrexroth-us.com The information given does not release the user from the obligation of own judgment
and verification. It must be remembered that our products are subject to a natural
process of wear and aging.