5.20.3 Tapered Member Speci cation


The following commands are used to specify section properties for tapered I-shapes.

General Format
argument-list = f1 f2 f3 f4 f5 (f6 f7)

Where:

f1 = Depth of section at start node.


f2 = Thickness of web.
f3 = Depth of section at end node.
f4 = Width of top ange.
f5 = Thickness of top ange.
f6 = Width of bottom ange. Defaults to f4 if left out.
f7 = Thickness of bottom ange. Defaults to f5 left out

Example
MEMBER PROPERTY
1 TO 5 TAPERED 13.98 0.285 13.98 6.745 .455 6.745 .455

Notes
a. All dimensions (f1, f2, .....f7) should be in current units.
b. f1 (Depth of section at start node) should always be greater than f3 (Depth of section at end node). You
must provide the member incidences accordingly.