Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

Volume 1 - Topside Equipment 616

OREDA-2009
Taxonomy no ltem Valves
4.4.13.4
Valvesdescribed by application
Relief
PSV• Conventional
Population lnstallations Aggregated time in service (106 hours) No of demands
23 3
Calendar time • Operational time '
0.6597 0.6591
Fallure mode Noof Failure rate (per106 hours). Active rep.hrs Manhours
failures Lower Mean Upper SD n/t Mean Max Mean

Critical 1' 0.02 1.36 4.26 1.52 1.52 4.0 4.0+ 8


1t 0.02 1.36 4.26 1.52 1.52
Fail to open ondemand 1' 0.0 2 1.36 4.26 1.52 1.52 4.0 4.0+ 8
1t 0.02 1.36 4.26 1.52 1.52
lncipient 5' 1.87 7.24 15.48 4.32 7.58 5.8
5t 1.87 7.25 15.49 4.33 7.59 3.3
Structural defrciency 1' 0.03 2.24 7.17 2.59 1.52 8
1t 0.03 2.24 7.18 2.60 1.52
Other 4' 0.31 4.94 14.40 4.77 6.06 6.07 3.3 4.0+ 5.3
4t 0.31 4.94 14.41 4.77

AIImodes 6' 2.06 8.46 18.42 5.21 9.1 3.4 4.0+ 6.2
6+ 2.07 8.47 18.43 5.21 9.1
Comments

©OREDA
No of demands

Manhours
Max

8.0+

8.0+

8.0+

8.0+

8.0+

8.0+