rSCADA the complete scada solution

CAT#217R2/310508/A
rSCADA v7X.X

About Radix
Radix is a leading Indian company manufacturing instruments as well as sensors. It was established in 1980.

Our instrument range includes PID and ONOFF controllers, timers, counters and rate indicators, RS485 / MODBUS / SCADA
systems and signal conditioners.

RTDs, thermocouples, thermowells & cables are available in thousands of varieties made to order. High quality Bourdon Tube
Pressure Gauges, Proximity Sensors and Photoelectric Sensors complete the sensors range.

The large combination of instrument and sensor products allows Radix to provide a one-stop solution to your process
instrumentation needs.

Radix has manufacturing facilities in Mumbai and Pune, and sales offices in many of the major Indian cities. It has one of the
best design competencies in India.

Radix brings you rSCADA - a full-featured, cost-effective SCADA solution.

Index

OVERVIEW 3

CONFIGURATION 4

rSCADA README 4

DEFAULT SCREEN CONFIGURATION 4

DEVICE SELECTION 4

ALARM LOG FILE SELECTION 5

TAG CONFIGURATION EDITOR 5

TRENDING 6

HISTORICAL DATA VIEWER (LIVE & HISTORICAL TRENDS) 6

HYPER TREND CURSORS 6

HYPER TREND PROPERTIES 6

HDV ZOOM IN / ZOOM OUT 7

ALARMS 7

MIMIC SCREENS 8

REPORT GENERATION 9

FDA 21 CFR PART 11 10

LOGIN 10

EDIT USER ACCOUNT 10

USER ACCOUNT PROPERTIES 10

ACCESS RIGHTS 11

AUDIT TRAIL REPORT 11

LOGOUT 11

FACILITIES LIST 12

COMPUTER CONFIGURATION FOR rSCADA 12

FAQ 12

rSCADA COMPATIBLE PRODUCTS 13


rSCADA v7X.X

OVERVIEW

rSCADA is an integrated and full-featured SCADA software from Radix.

rSCADA is based on the Labview platform from National Instruments. This gives it all the immense
functionality, flexibility and power of Labview.

Radix also manufactures sensors, transmitters, isolators and RS485 compatible instruments. Together with
rSCADA, Radix offers end-to-end solutions for a variety of process monitoring applications.

· Flexible trend facility - current and historical


· Alarm function
· Allows read (acquire data) & write (program setpoint, etc) operations
· Supports thousands of tags
· Supports upto 32 or more instruments
· Capable of storing data upto 10 years
· Compatible with a variety of Radix instruments such as Scanner, PID & ONOFF controllers, Isolators
· Default screen selection
· 21CFR PART11 version also available
· Ethernet connectivity also available

RS232 to RS485
Converter RS485 BUS

rSCADA
RS232

D+ D- D+ D- D+ D- D+ D-

Upto 32 devices

ISOSCAN SCANNER

MSI4P SIGNAL ISOLATOR - MULTIOUTPUT

MSI7P SIGNAL ISOLATOR - MULTIOUTPUT

HX96A RH + T ONOFF CONTROLLER

Typically, rSCADA is supplied as an .exe file. The Radix instruments which can be connected, and how many, is
factory set. The user is able to use all the features and facilities that are required during RUN time. For example,
giving/changing tag names, modifying trend screens for number of trends, X and Y axis scaling, setting logging
interval, etc.

This approach allows a cost-effective, ready-to-use solution even for small and tiny applications.

Also, the user needs no programming skills, and minimal skills to use rSCADA. Anyone familiar with a computer
should be able to work with rSCADA.

3
rSCADA v7X.X

CONFIGURATION

rSCADA Startup Screen

proceed sequentially go directly to default quit rSCADA


screen selected by user

Default Screen Configuration

rSCADA allows the user to select any of 9 screens as the default screen. For example, if Front Panel
Mimic is selected, the user can select any given instrument’s Front Panel Mimic as a default screen.

Device Selection
This screen lists all the devices which can be
connected to the bus. The user can select or
deselect devices.

rSCADA allows the user to configure a maximum


of 32 instruments on one RS485 bus. The actual
number and type of instruments in the rSCADA
configuration supplied is given in the screen.

4
rSCADA v7X.X

Alarm Log File Selection


rSCADA allows logging of the alarm status into
an MS Excel file.
The file may be new or existing.

Tag Configuration Editor

Here, the use can :


- Give Tag Names, eg ISOSCAN1.PV1
- Make Tag Groups, eg Boiler, Compressor
- Give Tag Descriptions, eg BOILER INPUT TEMPERATURE for ISOSCAN1.PV1

The Tag Groups feature allows the user to view desired tags together in trends, MS Excel sheets, etc.

Here, the user can also set, for every tag :


Update deadband
Log deadband
Log resolution
Update rate

5
rSCADA v7X.X

TRENDING
Historical Data Viewer (Live & Historical Trends)

The trends facility in rSCADA is called HDV (Historical Data Viewer). The facilities in HDV allow great
flexibility to the user.
· Any number of trend screens (factory set)
· Any number of trends in one screen
· View historical trends like live trends
· Multiple Y-axes with independent scale for each
· Time axis scaling from milliseconds to days
· Switch between real time and historical trends with one button click.
· Export trend values to MS Excel, etc.
· Zoom in/out
· Scroll along the time (X) axis to view recorded data from any time period
See Facilities List (P11) for more information.

Hyper Trend Cursors


Clicking on button will open a cursor
dialog box giving options for selection of
either one or two cursors.

Displays values of individual data points and


calculates time differences and frequencies in
case of two cursors.

Hyper Trend Properties


The Hyper Trend Properties dialog box is
used to modify settings of HDV display:

· Setting of X-axis limits width


· Listing tag names of the selected group
in channels/traces list box
· Addition and deletion of multiple Y axes
and assigning them to tags
· Setting of Y-axis limits
· Labeling of Y-axis
· Hide/unhide major and minor grid lines

6
rSCADA v7X.X

HDV Before Zooming HDV After Zooming

Zoom in or zoom out in the HDV screen using .

You can zoom in on any area of interest by simply dragging a cursor box around the relevant part
of the trend.

ALARMS

Alarm Popup

The ‘Alarm Popup’ window


pops up whenever an alarm
goes ON or OFF.

Historical Alarms

Alarms logged in an MS Excel file (P4) can be viewed with this button.

7
rSCADA v7X.X
MIMIC SCREENS

Front Panel Mimic

View fascia of any instrument


connected (P3).

Click to open a list box containing all


the device names selected (P3).

The screen along side shows the fascia of


instrument ISOSCAN_1.

Plant Mimic
Mimics which graphically represent the user’s
process can be made. This may require .jpg or
similar images of the process.

Tabular Mimic

Read parameters (PV, SP) and write programmable parameters (SP).

8
rSCADA v7X.X

REPORT GENERATION

Exports historical data to a new file in


the ‘Historical Data Files’ folder based
on start time, stop time and sample
interval in seconds (minimum 1sec).
Data may pertain to one or more Tags,
or one or more Tag Groups.

A folder ‘Historical Data Files’ is


generated automatically by rSCADA.

Historical Data

Click on ‘View Data’ option to retrieve the selected file from the ‘Historical Data Files’ folder.
Prints the selected file if ‘PRINT’ is clicked.

9
rSCADA v7X.X

FDA 21 CFR Part 11


rSCADA is also available in a version meeting the requirements of 21 CFR Part 11. Essentially, a variety of
features are available that ensure a controlled, secure & recorded operation of the software.

User Login

Prompts the user to login with a valid username and password.

This event gets logged in audit trail report for security.

Security menu consists


X
of the following:
Options · Options
· User Info
· Edit User Accounts
User Info

Edit User Accounts

Edit User Account


Allows to create new user account
or edits previously created user
accounts

User Account Properties

Group Memberships

Assigns a group to the current user account.


Select the group to be assigned from the
‘Not member of’ list box and click ‘Add’ to
add the group in ‘Member of’ list box.
User Account Manager allows to:
· Create user and group accounts
· Assign passwords
· Set the security level for a user
· Add or remove users in a group
· Password expiry
· Automatic logoff at idle

10
rSCADA v7X.X

Access Rights
Tool Access : To set permissions for accessing the Tag Configuration Editor, Tag Engine and
Historical Data Viewer.

Edit : To open access rights


dialog box for giving
access rights.

Access rights include:


· Full Access
· Read
· Edit
· Custom
· No Access

By default everyone has full access rights but different users and
groups can be configured and given access rights depending
upon administrator’s decision. This is done by click on Add
button in access rights dialog box.

Audit Trail Report


View audit report as per 21CFR PART 11standards for security purpose. Audit report
gives information regarding Date, Time, User name, Feature accessed and Access rights.

Logout
Logs out the currently active user and gives a prompt, if the user has been successfully
logged out. This event gets recorded in audit trail report for security
11
rSCADA v7X.X
FACILITIES LIST
FACILITIES USER FACTORY
SETTING SETTING
Configuration
Support 32 slave devices on one RS485 bus
Default screen selection
Supports thousands of tags
Change tag name, tag group & tag description as required
Update deadband & update rate settings
Online alarm display
Store data upto 10 years
FDA 21 CFR Part 11 Version
Create / update user & group account
Add / remove users in a group
Unique user ID
Password expiry limit
Security levels for different users
Automatic log off in idle condition
Secure audit file
Audit reporting
Mimic Screens
Front Panel Mimic
Plant Mimic
Tabular Mimic
Customised
Trending
Realtime & historical data switching
Export trend values to MS EXCEL with selectable sample interval
Unlimited no. of pen trends in one trend screen
Hide/unhide tag names on screen
Adjustable time span
Data scrolling along time axis
Zoom & pan
Multiple Y axes
Addition / Deletion of Y axes on screen
Labeling of each Y axes
Hide/unhide major & minor grid lines
2 cursors for minimum & maximum time interval
Time interval & frequency display between cursor
Report Generation
Alarm status logging
Generate report with start time, stop time & sample interval

COMPUTER CONFIGURATION FOR rSCADA


· IBM compatible PC P4 & above
· Operating system : MS WINDOWS 2000 / XP
· 512 MB free disk space
· 256 MB RAM, 512 MB preferred
· Display resolution : 1024 x 768 pixels

FAQ
Q : Can I change the type and quantity of instruments connected to my rSCADA systems?
A : rSCADA is supplied factory configured for this. Thus, if you had specified 2 scanners when ordering,
you cannot add a 3rd, or replace one scanner with a RH+T indicator.

Q : Why this inflexibility?


A : rSCADA has taken this approach to keep costs down. For example, rSCADA is cost effective even
when used with just one scanner, providing to the user all the power and features of a system that
would cost three times as much.

Q : In which applications is rSCADA most suitable?


A : rSCADA is primarily for users who have a reasonably clear application, and want a solution that works
from day one, without any special computer or programming skills.

Q : Can rSCADA be supplied with instruments of other makes?


A : Generally, no. But if the cost is justified, we might do such integration.

12
rSCADA v7X.X

rSCADA COMPATIBLE PRODUCTS


Radix manufactures a wide range of process instruments which are compatible with rSCADA.
These include :
· Single and dual channel indicators
· Single and dual channel ONOFF controllers
· PID controllers
· Flow rate indicator / totaliser
· Signal isolators
· RH+T indicator/controller
· Scanners
· FLAMEPROOF versions of the above

MULTICHANNEL SCANNER
• Upto 16 inputs/16 outputs
• For Temperature, Pressure, Flow, Level, RH, Conductivity, etc.
• Various Input (X)/Output (Y) combinations :
X4Y0, X4Y8, X8Y4, X8Y16, X16Y16, etc
• Universal Input : 8 Thermocouples, Pt100, mV or mA input front
panel selection without DIP for each channel
• Front panel user calibration
• Input burn protection
• Non-volatile memory for parameters - no batteries
• 3 key, 5 level programming
• Setpoint and level locks
ISOSCAN-H • Tactile membrane keypad
96x192x220 • 5 software versions : Indicator, Multisetpoint, Grouping, etc
• RS485 with MODBUS RTU
ISOSCAN-V • Powerful, flexible SCADA software available
192x96x220 • Option : Printer interface (no computer needed)
• 85~265 V AC SMPS or 24 V DC supply

X48 X96, X49 PM964


AUTOTUNE PID CONTROLLER AUTOTUNE PID CONTROLLER 6-DIGIT PROCESS INDICATOR WITH ALARMS

• Universal input • Two universal input • Inputs : 0~20 mA, 4~20 mA, 0~5 V, 1~5 V, 0~10 V
• 1 / 2 / 3 setpoints • 1 / 2 / 3 setpoints • Range : -19999 to +99999
• Isolated 0/4~20 mA • 2 x Isolated 0/4~20 mA • Isolated 0/4~20 mA
• PID, Proportional and ONOFF control • PID, Proportional and ONOFF control • Four alarms

X96A X48A, X49A FLOTO


PROGRAMMABLE ONOFF CONTROLLER PROGRAMMABLE ONOFF CONTROLLER FLOW RATE INDICATOR/TOTALISER

• 6 digit flow rate indicator,


• Two universal input • Universal input 8 digit flow totaliser
• 1 / 2 / 3 / 4 setpoints • 1 / 2 / 3 setpoints • Inputs : 0~20 mA, 4~20 mA, 0~5 V, 1~5 V
• Isolated 2 x 0/4~20 mA • Isolated 0/4~20 mA 0~10 V, 0~10 khz
• ONOFF control • ONOFF control • Two batch relays, two alarm relays

MSI7P MSI4P HX96A


SIGNAL ISOLATOR - MULTIOUTPUT SIGNAL ISOLATOR - MULTIOUTPUT RH + T ONOFF CONTROLLER

• Universal input • Universal input • Input : RH and T


• 3 / 4 / 5 x 4~20 mA (or voltage) outputs • 1 or 2 x 4~20 mA (or voltage) outputs • 0 / 1 / 2 / 3 setpoints
• Input/supply/outputs mutually isolated • Input/supply/outputs mutually isolated • User programmable
• 2 x 16 character LCD display • 4 digit, 7-segment LCD display • Sensor break indication

13
rSCADA the complete scada solution