Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
Split Type Air Conditioners
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion. DC Inverter Control 50/60 Hz
Read the user’s manual carefully before using this product. The user’s manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
Urusara 7
If you have any enquiries, please contact your local importer, distributor and/or retailer.
FTKJ Series
FTKV Series
Cautions on product corrosion FTKC Series
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Urusara 7
FTKJ Series
Specifications, designs and other content appearing in this brochure are current as of January 2016 but subject to change without notice. c All rights reserved PC
Lineup of DC Inverter Air Conditio ners with R-32 Refrigerant
Daikin is the sole manufacturer to produce both air conditioning equipment and refrigerants worldwide. Our cutting-edge technologies and use of advanced R-32 refrigerant provide
enhanced comfort while reducing the impact on climate change.
1.5 kW Class 2.0 kW Class 2.5 kW Class 3.5 kW Class 5.0 kW Class 6.0 kW Class 7.1 kW Class
Urusara 7
FTKJ Series
FTKV Series
NEW
NEW indicates a model with a new design. NEW indicates a model with a new capacity class.
1 2
Urusara 7
Features
Redesigned air intake and heat exchanger
World-first 3 humidity control technology
Precision circulation airflow
Reliable streamer discharge air purification
Convenient automatic filter cleaning system
Innovative design with Japanese aesthetic
Remote control via smartphone (optional adaptor)
Notes: 1. This is for residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched Urusara 7 in the Japanese market.
2. In January 2013, the 4.0 to 7.1 kW class models for the Japanese market received the Minister’s Prize from Japan’s Ministry of
Economy, Trade and Industry in the Fiscal 2012 Grand Prizes for Excellence in Energy Efficiency and Conservation.
3. As of 1999, when Daikin launched Ururu Sarara in the residential-use air conditioner market.
3 4
FTKJ Series
Features
Energy-saving COP of 3.59 to 4.81
Stylish finish in eye-pleasing colours
Wide selection of comfort technologies
Whisper quiet sound level
Remote control via smartphone (optional adaptor)
White Silver
5 6
Urusara 7 Contents of FTKV and FTKC Series
Heat Pump
FTXZ25/35/50
P15 Next Generation R-32 Refrigerant P27 Set and Forget On/Off Operation
FTKJ Series
Cooling Only
FTKJ25/35/50 (white) FTKJ25/35/50 (silver)
kW 2.5
2.45(1.2-3.4)
(0.6-3.9) 3.5 (1.3-4.1)
3.45 (0.6-5.3) 5.2 (1.7-5.5)
4.95 (0.6-5.8)
Cooling capacity Rated (Min.-Max.)
Btu/h 8,500 (4,100-11,600) 11,900 (4,400-14,000) 17,700 (5,800-18,800)
Dimensions (H × W × D) mm 303 x 998 x 212 P33 Function List of FTKV and FTKC Series
P35 Functions
Outdoor unit RKJ25 RKJ35 RKJ50
P37 Wireless Remote Controller
Dimensions (H × W × D) mm 550 x 765 x 285 735 x 825 x 300 P39 Specifications for FTKV Series
P21 Less Wasted Energy with Infrared Sensors P41 Specifications for FTKC Series
Options for FTKC Series
FTKV and FTKC Series
Features
Improved performance over non-inverter models
Optimal control with Intelligent Eye and Econo Mode
Advanced comfort features including 3D Airflow
Greater convenience with weekly scheduling
Titanium Apatite Photocatalytic Air-Purifying Filter
Remote control via smartphone (optional adaptor)
FTKV25/35
FTKC25/35
Lineup of FTKV Series
FTKV Series Cooling Only
FTKV25/35NVM
RKV25/35NVM
FTKV50/60NVM
FTKV71NVM
RKV50/60NVM
RKV71NVM
11 12
Lineup of FTKC Series
FTKC Series Cooling Only
FTKC15/20PVM
RKC15/20PVM
NEW
NEW
FTKC25/35QVM
FTKC50/60/71QVM
RKC25/35QVM
5.0 kW Class FTKC50QVM / RKC50QVM
RKC50/60/71QVM Rated kW 5.2 (1.4-6.0)
Cooling Capacity
(Min.-Max.) Btu/h 17,700 (4,800-20,500)
6.0 kW Class FTKC60QVM / RKC60QVM
Rated kW 6.0 (1.4-6.7)
Cooling Capacity
(Min.-Max.) Btu/h 20,500 (4,800-22,900)
2.5 kW Class FTKC25QVM / RKC25QVM
NEW 7.1 kW Class FTKC71QVM / RKC71QVM
Rated kW 2.5 (1.0-3.4)
Cooling Capacity kW 7.1 (2.1-7.5)
(Min.-Max.) Btu/h 8,500 (3,400-11,600) Cooling Capacity Rated
(Min.-Max.) Btu/h 24,200 (7,200-25,600)
3.5 kW Class FTKC35QVM / RKC35QVM
Rated kW 3.5 (1.3-4.1)
Cooling Capacity
(Min.-Max.) Btu/h 11,900 (4,400-14,000)
NEW indicates a model with a new design. NEW indicates a model with a new capacity class.
13 14
Next-Generation R-32 Refrig erant
As the sole worldwide manufacturer of both air conditioning equipment and refrigerants, Daikin is continuously researching
refrigerants as well as new technologies that can reduce energy consumption. Use of refrigerants with a lower impact on Increased Energy Efficiency
global warming is urgently required as climate change has become one of the most critical global issues. Daikin has now
adopted R-32. This next-generation refrigerant does not deplete the ozone layer and has a lower impact on global warming. The potential refrigerating effect of R-32 is 1.5 times that of R-410A.
Thus the piping diameter can be smaller.
Pressure (kPa)
regulations selected R-410A (HFC). 1,900
rming 1,500
R-410A refrigerating effect
Less Impact on Global Warming
1,100
R-22 refrigerating effect
The Earth retains solar heat in the daytime for
warming and then releases this heat at night, Global Warming Potential1 700
allowing it to maintain an optimal temperature R-32 refrigerating effect, 1.5 times that of R-22 or R-410A
2,500
range. However, with greenhouse gases increas- 300
200 300 400 500 600
ing, it is more difficult to discharge heat and the 2,000
Enthalpy (kJ/kg)
planet is gradually becoming warmer. This is
1,500
called global warming. R-32 has only around
30% of the global warming potential of R-410A 1,000 2,090 1,810
and R-22. Refrigerants: Heat Release in Air Conditioning Systems
500
675 Similar Mechanism to Human Body Effective Release of Heat Refrigerant Flow during Cooling
An air conditioner functions in a surpris- Refrigerant is changed from gas to liquid
Solar radiation
ingly similar way to the human body. in the outdoor heat exchanger, after which
Greenhouse gas R-32 R-410A R-22 In the body, blood carries heat as it it is evaporated in the indoor heat
Infrared radiation circulates and helps to release excess exchanger. During cooling operation,
heat through sweating. Refrigerant also cool air is discharged from the indoor unit
Sea Land carries heat and helps to adjust tempera- while heat is removed from the air taken in
ture through heat exchange. from inside the room. This heat is
Greenhouse gases cause damage which delivered to the outdoor unit and released.
allows solar radiation to pass through the
Earth’s outer atmosphere while also trapping
infrared radiation. These gases rapidly Note: 1. Global warming potential values are based on the Fourth Assessment Report from the Intergovernmental Panel on Climate Change (IPCC).
increase and interfere with the Earth’s ability to
release heat into space, causing the ambient
temperature to rise.
15 16
Inverter Air Conditioners Reduce Electricity Consumption
Lower Electricity Consumption Powerful and Energy Saving
Inverters are devices that are able to vary their capacity by Inverter models operate at maximum capacity (100%
adjusting operating frequency. This allows inverter air condi- load) to quickly reach the set temperature. They then FTKV50NVM
tioners to cut electricity use compared to non-inverter models. reduce operation to low capacity (partial load), which
Maximum capacity
An inverter system can help to noticeably reduce household is sufficient to maintain the set temperature. This 6.0 kW
Capacity
power bills. allows inverter models to operate at low capacity
If you select Auto Fan Speed, your inverter air conditioner will operate at maximum efficiency without any further (partial load) most of the time.
setting. It will not start and stop its compressor to maintain the room temperature. You can also go out of the room for
a short time without any worries. Minimum capacity
1.7 kW
FTKV50NVM
Comfortable
Maximum capacity
Time
Temp.
Inverter air conditioners vary their capacity by adjust- Rotations Set temp. Inverter
ing the rotation speed of their compressors. In Controls rotation according
contrast, non-inverter models have a fixed capacity to required power
and can only control the room temperature by starting
Inverter Large loss of electricity
or stopping their compressors. Non-inverter Too cool
Starts Time
Time
17 18
All Models Feature High Ene rgy Efficiencies
COPs of 3.55 to 4.63 Daikin DC Inverter Technologies
The FTKV series achieves COPs of 3.55 to 4.63 thanks to Daikin’s DC Inverter control and next-generation R-32 refrigerant. DC Inverter Control
The FTKV25 achieves a COP of 4.63,13% higher than the conventional FTKS25. The FTKV35 achieves a COP of 3.85,16% DC Inverter is Daikin’s term for an inverter air conditioner equipped with a DC motor. These motors use magnets to generate
higher than the conventional FTKS35. rotation, making them more efficient than AC motors. Daikin has fitted its advanced DC motors for compressors and fan motors with
powerful neodymium magnets to achieve even greater efficiency. It calls these devices Reluctance DC motors.
New Conventional
Swing Compressor
Rated COP
With its smooth rotation, the swing compressor
3 4 5 significantly decreases friction and vibration. It
also eliminates the leakage of refrigerant gas
FTKV25NVM 4.63
during compression. These advantages provide
FTKS25GVMA 4.10 quiet and efficient operation.
The high performance of this Daikin original
technology was recognised in 1997 with the
Swing compressor receipt of an award from the Japan Society for
FTKV35NVM 3.85 the Promotion of the Machine Industry 1. The
3.31 compressor’s reputation for reliability has
FTKS35GVMA
grown considerably in the nearly 20 years since
this award was presented.
An air conditioner’s COP (coefficient of performance) indicates Capacity (W) Electromagnet Repelling power
how efficiently the unit uses energy. A higher COP means greater COP =
What Is COP? energy efficiency. It also means lower electricity consumption, Power consumption (W)
and of course lower power bills. Embedding high-strength neodymium magnets in the shaft turns the entire
centre of the motor into a powerful magnet. By rapidly switching the poles of
this electromagnet, the Reluctance DC motor is able to produce even
greater speed and power.
Notes: 1. This marked the development of a high-performance swing compressor that was compatible with
alternative fluorocarbons.
2. Daikin’s achievement was recognised by the Institute of Electrical Engineers of Japan at the 54th
Academic Promotion and Technical Development Awards in 1998.
19 20
Less Wasted Energy with Infra red Sensors
Intelligent Eye
Intelligent Eye prevents energy wastage by using its infrared sensors to detect human movement
in a room. If there is no movement for 20 minutes, it automatically adjusts the set temperature by
approximately 2°C. Once Intelligent Eye is turned on, it operates
automatically without any further setting.
This function is available for the FTKV series and FTKC25/35/50/60/71.
Econo Mode
This function limits the maximum power consumption. It helps to
reduce power usage if the cooling load is high, for example, at startup
or during large gatherings and periods of direct sunshine.
Normal operation
Power consumption
Econo Mode
Time
21 22
Choice of Wide Range of Airfl ow Patterns
When you choose the low angle, cool air slides off to
reach the corners of the room.
3D Airflow
3D Airflow combines Vertical and Horizontal
Auto-Swing to reduce indoor temperature
fluctuation. This function circulates air to
every part of a room for uniform cooling of 1 Comfort Airflow Mode
even large spaces. To start 3D Airflow, push
both the Vertical and Horizontal Auto-Swing Comfort Airflow Mode prevents uncomfortable
buttons. The flaps and louvers swing in turn. drafts from blowing directly on to a person’s body.
4 2
This function is available for the FTKV50/60/71. During cooling operation, the flap moves upward to
prevent cold drafts.
This function is available for the FTKV50/60/71 and FTKC series.
The flaps and louvers swing in turn, expanding the comfort zone.
23 24
Quiet Nights in Your Neighbo urhood
This function decreases the sound pressure level by 3 to 7 RKC60 ON HR. OFF HR.
dB (A) below the rated operation. It provides a sound Stops the unit after three hours
Operations Sound pressure levels
pressure level of 43 dB (A) for the RKV25 and RKC50/60. and starts it again eight hours later.
Capacity may decrease when Outdoor Unit Quiet Operation Rated (H) 50 dB (A)
is selected. 7 dB (A)
Quiet (SL) 43 dB (A)
This function is not available for the RKC15/20.
Note: 1. Based on “Examples of Sound Pressure Levels”, Ministry of the Environment, Japan, November 2002.
25 26
Set and Forget On/Off Opera tion
Programme 2 Programme 2
Off
8:00 a.m.
Off
3:00 a.m.
The Weekly Timer will automatically stop operation after you leave home on Even if you go to bed at 0:00 a.m., the air conditioner will operate for another
a busy morning. You can forget about the air conditioner. three hours so you continue to sleep comfortably. Stopping operation during
the night prevents overcooling and saves you from catching a chill.
Programme 3 Programme 3
The Weekly Timer will automatically stop operation when you go to bed. The Weekly Timer will automatically stop operation when you leave home.
27 28
Photocatalytic Air Purifying
Anti-Corrosion Treatment of
Outdoor Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion
treatment. The surface is covered with a thin acrylic resin layer to provide enhanced resis-
tance to acid rain and salt corrosion.
Corrosion-resistant
acrylic resin
Note: 1. This practical application of titanium apatite was a world first. Announced in September 2003 at the 3rd
International Workshop on the Utilization and Commercialization of Photocatalytic Systems, Coatings for
Clean Surfaces, Water and Air Purification.
29 30
Remote Control via Smartph one
Functions
Smart Control by Smartphone
Start/stop operation Monitor current outdoor temperature4
The Daikin mobile controller application lets you manage Daikin inverter air conditioners
from anywhere, helping to maintain a comfortable home environment while saving energy. Set operation mode Set child-proof lock 3
This convenient app gives you full control of core functions such as start/stop, opera- Set room temperature Set weekly timer:
tion mode and set temperature as well as advanced features like weekly scheduling. The
app also lets you monitor your system to ensure it is performing as desired. Set fan speed 3
Setup is extremely easy. After downloading the software, you only need to connect to
Set airflow direction3
a private wireless network inside your home or mobile network outside.1
Monitor current room temperature actions per day, 28 actions in total)
System Configuration
In Home
Operation Wireless Internet Environment at Home
KRP067A41 or KRP980B2
your home, you can easily monitor and adjust Users need to prepare items (1) to (3).
points such as the operating status and room A Daikin mobile controller (optional adaptor) is required for each indoor unit.
Functions
DC Inverter Control
Power-Airflow Dual Flaps
Power-Airflow Flap
Comfortable Airflow
Wide-Angle Louvers
3D Airflow
Intelligent Eye
Econo Mode
Weekly Timer
Functions
33 34
Functions
Power-Airflow Dual Flaps Indoor Unit Quiet Operation Standby Electricity Saving 24 Hour On/Off Timer
The Power-Airflow Dual Flaps can flatten out during cooling operation to Indoor unit operating sound pressure levels can be decreased from the Even when an air conditioner is not operating, it requires standby power. This timer can start or stop the air conditioner within a 24 hour period. It
deliver cool air to the corners of a room. Low setting fan speed using the wireless remote controller. However, thanks to this function, the required standby power can be reduced. can be preset in 10 minute steps by pressing the On/Off Timer button on
See page 23 See page 25 See page 22 the wireless remote controller. The On Timer and Off Timer can be used
in combination.
Outdoor Unit Quiet Operation See page 26
Power-Airflow Flap Econo Mode
Outdoor unit operating sound pressure levels can be decreased from the This mode limits maximum power consumption. It improves operating
The Power-Airflow Flap flattens out during cooling operation to deliver rated operation sound using the wireless remote controller. Count Up-Down On/Off Timer
cool air to the corners of a room. efficiency and also prevents circuit breakers from being overloaded.
See page 25
See page 22
The operation start and stop times can be set with the touch of a single
See page 23 button and preset for a period of one to 12 hours in one hour increments.
Auto Fan Speed When the Off Timer is set, Night Set Mode is activated automatically.
The microprocessor automatically adjusts the fan speed to high to rapidly Inverter Powerful Operation See page 26
Wide-Angle Louvers This function boosts cooling performance for 20 minute period. It is
The Wide-Angle Louvers provide wide airflow coverage for effective reach the set temperature. Once the temperature is achieved, this function
reduces the fan speed to low. convenient when the air conditioner is first turned on or it is necessary to
operation no matter where the indoor unit is placed in a room. change the room temperature quickly. Weekly Timer
See page 24
See page 24
The Weekly Timer allows up to four actions to be programmed for each
Intelligent Eye day of the week. It is possible to schedule not only the on and off times,
Intelligent Eye with its infrared sensor automatically controls air but also the desired temperatures during these periods. The copy function
Vertical Auto-Swing (up and down) conditioner operation according to human movement in a room. When Wireless Remote Controller with Backlight also makes the setting much easier and enables a daily programme to be
This function automatically moves the flaps up and down to distribute air there is no movement for 20 minutes, it adjusts the temperature by The backlit LCD allows easy operation in repeated on other days as required.
across a room. approximately 2°C for energy savings. the dark. Frequently used functions are See pages 27 and 28
See page 21 conveniently located on the front of the
Top view Side view controller.
Horizontal Auto-Swing (left and right) 7m Night Set Mode
Horizontal Auto-Swing automatically moves the louvers to the left and Pressing the Off Timer button automatically selects Night Set Mode. This
7m
right to cover a room with cool air. function prevents excessive cooling for a pleasant sleep. After 60 minutes,
90˚ the room temperature is raised by 0.5 C for cooling operation.
110˚
See page 26
3D Airflow Daikin Mobile Controller (optional adaptor) +0.5 C Cooling
This function combines Vertical and Horizontal Auto-Swing to circulate a Set temp. before
This optional adaptor and its application turn a smartphone into a remote Off timer begins
cloud of cool air right to the corners of even large spaces. The flaps and Programme Dry Function to operate
controller that can be used inside or outside the home. Together they help
louvers swing in turn. The microprocessor works to eliminate humidity while maintaining the
to maintain comfort while saving energy and eliminate any worries about
See page 23 most consistent temperature possible. It automatically controls the Time
temperature and fan speed. forgetting to turn off the air conditioner.
60 min. Unit: minutes
See pages 31 and 32
Off timer turns on Off timer stops air conditioner
Comfort Airflow Mode
This function prevents uncomfortable drafts from blowing directly on to the Indoor Unit On/Off Switch
body. To prevent drafts, the flap moves upward during cooling operation. Cleanliness Worry Free
The unit can be conveniently started by hand if the wireless remote
See page 24 controller is misplaced or its batteries are not charged.
Titanium Apatite Photocatalytic
Auto-Restart after Power Failure
Air-Purifying Filter The air conditioner memorises the settings for operation mode (cooling,
This filter contains the advanced photocatalytic material titanium apatite. dry and fan only), airflow, temperature, etc., and automatically returns to
While the filter’s micron-level fibres trap dust, this photocatalyst adsorbs them when power is restored after a power failure.
and decomposes bacteria. The filter can be used for up to three years with
proper maintenance.
See pages 29 and 30 Self-Diagnosis with Digital Display
Bottom view
Indoor Unit On/Off Switch Malfunction codes are shown on the digital display panel of the wireless
remote controller for fast and easy maintenance.
Wipe-Clean Flat Panel
The flat panel design can be cleaned with only the single pass of a cloth
across its smooth surface. The flat panel can also be easily removed for Anti-Corrosion Treatment of Outdoor
more thorough cleaning. Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are processed using a special
anti-corrosion treatment. The surface is covered with a thin acrylic resin
layer to enhance the fins’ resistance to acid rain and salt corrosion.
See page 30
35 36
Wireless Remote Controller
FTKV25/35 FTKC15/20
The backlit LCD allows easy
operation in the dark.
On and Off switch 1 8 Sets room temperature. Sets room temperature. 1 8 On and Off switch
1
Selects fan speed. 1 9 Econo Mode Econo Mode 2 2
Auto Fan Speed and 2 8 9 Selects fan speed. Auto Fan Speed and
3 Indoor Unit Quiet Operation
Indoor Unit Quiet Operation 2 8 10 Sets vertical airflow direction. Inverter Powerful Operation 3 9
3 Vertical Auto-Swing 4 10
Inverter Powerful Operation 3 9 10 Sets vertical airflow direction.
Selects operation mode: 5 Vertical Auto-Swing
4 10 11 Intelligent Eye Cooling, Dry and Fan Only. 4 6 11
Selects operation mode: 5 11 12 11 Cancels timer.
Cooling, Dry and Fan Only. 4 12 Selects time. 7 13
Comfort Airflow Mode 5
14 12 Selects time.
Outdoor Unit Quiet Operation 5 12 13 24 Hour On Timer 24 Hour On Timer 6
6 13 13 Resets settings.
24 Hour Off Timer and 7 14 14 Sets clock. 24 Hour Off Timer and
6 14 Sets clock.
Night Set Mode 7
Night Set Mode
Cancels timers. 7
14 Sets clock.
37 38
Specifications for FTKV Series Options for FTKV Series
Indoor Unit
Indoor unit FTKV25NVM FTKV35NVM FTKV50NVM FTKV60NVM FTKV71NVM No. Item FTKV25/35/50/60/71
Model name *1
Outdoor unit RKV25NVM RKV35NVM RKV50NVM RKV60NVM RKV71NVM 1 5-room centralised controller KRC72A
kW 2.5 (1.2-3.4) 3.5 (1.3-4.1) 5.2 (1.7-6.0) 6.0 (1.9-7.0) 7.1 (2.3-8.9) 2 Wiring adaptor for time clock/remote controller *2
Rated KRP413AB1S
Capacity 8,500 11,900 17,700 20,500 24,200 (Normal open pulse contact/normal open contact)
(Min.-Max.) Btu/h
(4,100-11,600) (4,400-14,000) (5,800-20,500) (6,500-23,900) (7,800-30,400) 3 Titanium apatite photocatalytic air-purifying filter *3 KAF970A46
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz 4 Remote controller loss prevention with chain KKF910A4
Running current 5 Daikin mobile controller BRP072A42
(220-230-240 V, 50 Hz / A 2.7-2.9-2.8 / 2.7-2.9 4.4-4.2-4.0 / 4.4-4.2 6.0-5.7-5.5 / 6.0-5.7 7.4-7.1-6.8 / 7.4-7.1 9.3-8.9-8.5 / 9.3-8.9
220-230 V, 60 Hz) Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
Rated *2. The time clock and other devices should be obtained locally.
Power consumption W 540 910 1,300 1,580 2,000 *3. The filter is a standard accessory.
COP W/W 4.63 3.85 4.00 3.80 3.55
Indoor unit FTKV25NVM FTKV35NVM FTKV50NVM FTKV60NVM FTKV71NVM
Front panel colour Pure white
Airflow rate H m3/min (cfm) 7.8 (275) 8.0 (282) 14.3 (504) 15.4 (544) 18.2 (643)
Fan speed 5 steps, quiet and automatic
5-room centralised controller Titanium apatite photocatalytic
Sound pressure levels H/L/SL dB (A) 37/25/22 38/26/23 43/34/31 45/35/32 46/37/33 air-purifying filter
KRC72A
Dimensions HxWxD mm 283 x 800 x 195 290 x 1,050 x 250 340 x 1,050 x 248 KAF970A46
Machine weight kg 9 12 14
Outdoor unit RKV25NVM RKV35NVM RKV50NVM RKV60NVM RKV71NVM
Casing colour Ivory white Outdoor Unit
No. Item RKV25/35 RKV50/60 RKV71
Type Hermetically sealed swing type
Compressor 1 Air direction adjustment grille KPW937A4 KPW945A4
Motor output W 800 1,300 2,400
2 Drain plug *1 KKP937A4 KKP945A4
Type R-32
Refrigerant Note: *1. One set includes five pieces for five units.
Charge kg 0.9 1.2 1.5
Sound pressure levels H/SL dB (A) 46/43 47/44 48/44 52/46 52/49
Dimensions HxWxD mm 550 x 765 x 285 735 x 825 x 300 770 x 900 x 320
Machine weight kg 34 43 60
Operation range °CDB 19.4 to 46 Air direction adjustment grille Drain plug
KPW945A4 KKP937A4
Liquid ø6.4
Piping
Gas mm ø9.5 ø12.7 ø15.9
connection
Drain ø18.0
Max. piping length 20 30 Control System
m No. Item FTKV25/35/50/60/71
Max. level difference 15 20
1 Central remote controller *1 DCS302CA61
Measurement conditions 2 Unified On/Off controller *1 DCS301BA61
1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m. *1
3 Schedule timer DST301BA61
2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
ambient conditions. 4 Interface adaptor for DIII-NET use KRP928BB2S
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
39 40
Specifications for FTKC Series
Indoor unit FTKC15PVM FTKC20PVM FTKC25QVM FTKC35QVM Indoor unit FTKC50QVM FTKC60QVM FTKC71QVM
Model name Model name
Outdoor unit RKC15PVM RKC20PVM RKC25QVM RKC35QVM Outdoor unit RKC50QVM RKC60QVM RKC71QVM
kW 1.5 (0.75-1.9) 2.0 (1.0-2.4) 2.5 (1.0-3.4) 3.5 (1.3-4.1) kW 5.2 (1.4-6.0) 6.0 (1.4-6.7) 7.1 (2.1-7.5)
Rated Rated
Capacity 5,100 6,800 8,500 11,900 Capacity 17,700 20,500 24,200
(Min.-Max.) Btu/h (Min.-Max.) Btu/h
(2,500-6,500) (3,400-8,200) (3,400-11,600) (4,400-14,000) (4,800-20,500)) (4,800-22,900) (7,200-25,600)
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Running current A 2.2 2.6 3.2 4.5 Running current A 6.3 8.0 10.9
Power consumption Rated W 337 500 680 (210-1,100) 960 (250-1,455) Power consumption Rated W 1,365 (260-1,730) 1,740 (300-2,060) 2,365 (400-2,550)
COP W/W 4.45 4.00 3.67 3.65 COP W/W 3.80 3.45 3.00
Indoor unit FTKC15PVM FTKC20PVM FTKC25QVM FTKC35QVM Indoor unit FTKC50QVM FTKC60QVM FTKC71QVM
Front panel colour Shiny pure white Shiny white Front panel colour Shiny white
Airflow rate H m3/min (cfm) 9.0 (318) 10.8 (381) Airflow rate H m3/min (cfm) 16.7 (590) 17.3 (611)
Fan speed 5 steps, quiet and automatic Fan speed 5 steps, quiet and automatic
Sound pressure levels H/L/SL dB (A) 38/25/22 38/25/19 39/26/22 Sound pressure levels H/L/SL dB (A) 44/35/29 45/36/30 46/37/31
Dimensions HxWxD mm 283 x 770 x 203 283 x 770 x 223 Dimensions HxWxD mm 295 x 990 x 263
Machine weight kg 8 Machine weight kg 13
Outdoor unit RKC15PVM RKC20PVM RKC25QVM RKC35QVM Outdoor unit RKC50QVM RKC60QVM RKC71QVM
Casing colour Ivory white Casing colour Ivory white
Type Hermetically sealed swing type Type Hermetically sealed swing type
Compressor Compressor
Motor output W 278 441 641 913 Motor output W 1,200 1,300
Type R-32 Type R-32
Refrigerant Refrigerant
Charge kg 0.50 0.70 Charge kg 1.00 1.05
Sound pressure levels H 46-47-47/48-49 47 49 Sound pressure levels H/SL dB (A) 49/43 50/43 51/46
(220-230-240 V, 50 HZ / dB (A)
220-230 V, 60 HZ) SL – 44 Dimensions HxWxD mm 595 x 845 x 300
Dimensions HxWxD mm 550 x 658 x 275 Machine weight kg 36 40
Machine weight kg 23 26 Operation range °CDB 19.4 to 46
Operation range °CDB 19.4 to 46 Liquid ø6.4
Piping
Liquid ø6.4 Gas mm ø12.7 ø15.9
Piping connection
Gas mm ø9.5 Drain ø16.0
connection
Drain ø16.0 Max. piping length 30
m
Max. piping length 15 Max. level difference 20
m
Max. level difference 12
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
Measurement conditions 2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m. ambient conditions.
2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
ambient conditions.
Outdoor Unit
No. Item RKC15/20 RKC25/35 RKC50/60/71
1 Air direction adjustment grille KPW937B4 KPW937D4 KPW5E112
2 Drain plug KKP937A4 *1 – Titanium apatite photocatalytic Remote controller loss
air-purifying filter prevention with chain
Note: *1. One set includes five pieces for five units. KKF917A4
KAF970A46
41 42