Clearing Alarm After Precomm BB Rbs 6601

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 6

CLEARING ALARM AFTER PRECOMM BB RBS 6601/6150

Hal ini berkaitan dengan :


 Enclosure Product Data Mismacth
 EcBus=1
 EcPort=1

1. Cek Master dan Slave suatu BB (master adalah true & slave adalah false) dgn command :
set . supportSystemControl true
set . supportSystemControl false

X3453918G_CO> get . supportsystem

171130-23:29:33 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


=================================================================================================================
MO Attribute Value
=================================================================================================================
EquipmentSupportFunction=1 supportSystemControl true
=================================================================================================================
Total: 1 MOs

2. Cek st field dan Locked PDU dan SAU bila menggunakan SUP dgn command bl proxy misal :
bl 302

X3453918G_CO> bl 302

171130-23:49:29 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


Block following 1 MOs ?
===================================================================================
302 Equipment=1,FieldReplaceableUnit=PDU-1
===================================================================================
Block 1 MOs. Are you Sure [y/n] ? y

============================================================================================================
Id MO administrativeState Result
============================================================================================================
302 FieldReplaceableUnit=PDU-1 0 >>> Set.
============================================================================================================
Total: 1 MOs attempted, 1 MOs set

Hasilnya :

X3453918G_CO> st field

171130-23:50:32 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


===================================================================================
Proxy Adm State Op. State MO
===================================================================================
286 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=1
302 0 (LOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=PDU-1
304 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
309 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
314 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-3
319 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-4
324 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-5
329 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-6
334 0 (LOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=SAU
368 1 (UNLOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=SCU
===================================================================================
Total: 10 MOs
3. Pada st field lakukan delete proxy milik SCU karena kita tidak memerlukan SCU tapi SUP dengan command “del proxy”,
contoh :

del 368

X3453918G_CO> del 368

171130-23:53:48 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


Delete following MOs ?
===================================================================================
368 Equipment=1,FieldReplaceableUnit=SCU
===================================================================================
!! Warning: Undo Mode is currently inactive !!
Delete 1 MOs. Are you Sure [y/n] ? y

Deleting ...
===================================================================================
368 Equipment=1,FieldReplaceableUnit=SCU >>> Mo deleted
===================================================================================
Total: 1 MOs attempted, 1 MOs deleted

Hasilnya SCU terdelete :

X3453918G_CO> st field

171130-23:53:51 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


===================================================================================
Proxy Adm State Op. State MO
===================================================================================
286 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=1
302 0 (LOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=PDU-1
304 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
309 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
314 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-3
319 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-4
324 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-5
329 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-6
334 0 (LOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=SAU
===================================================================================
Total: 9 MOs

4. Buat SUP dan ecport bila belum tersedia dengan command berikut (tinggal copas) :

confb+
gs+
crn Equipment=1,FieldReplaceableUnit=SUP
administrativeState 1
isSharedWithExternalMe
positionCoordinates
positionInformation
positionRef Cabinet=1
userLabel
end

crn Equipment=1,FieldReplaceableUnit=SUP,EcPort=1
cascadingOrder 0
ecBusRef EcBus=1
hubPosition X
end
confb-
gs-

5. Cek SUP, ecport dan ecbus sudah di buat dgn command :


st field
get ecport=1
get ecbus=1

Hasilnya :
X3453918G_CO> st field

171201-00:00:59 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


===================================================================================
Proxy Adm State Op. State MO
===================================================================================
286 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=1
302 0 (LOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=PDU-1
304 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-1
309 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-2
314 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-3
319 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-4
324 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-5
329 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=RRU-6
334 0 (LOCKED) 0 (DISABLED) Equipment=1,FieldReplaceableUnit=SAU
6127 1 (UNLOCKED) 1 (ENABLED) Equipment=1,FieldReplaceableUnit=SUP >>> SUP Ter Create
===================================================================================
Total: 10 MOs

Ecport ter create harus sesuai dibawah

OFFLINE_3453339G_CO-JALAN_TIMOR_NUSANTARA_U21L18> get ecport=1

171201-00:45:09 OFFLINE_3453339G_CO-JALAN_TIMOR_NUSANTARA_U21L18 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/7308


=================================================================================================================
541 Equipment=1,FieldReplaceableUnit=1,EcPort=1
=================================================================================================================
cascadingOrder 0
ecBusRef EcBus=1
ecPortId 1
hubPosition X >>> Master harus X
=================================================================================================================
558 Equipment=1,FieldReplaceableUnit=PDU-1,EcPort=1
=================================================================================================================
cascadingOrder 0
ecBusRef EcBus=1
ecPortId 1
hubPosition >>> Kosong
=================================================================================================================
631 Equipment=1,FieldReplaceableUnit=SAU,EcPort=1
=================================================================================================================
cascadingOrder 0
ecBusRef EcBus=1
ecPortId 1
hubPosition >>> Kosong
=================================================================================================================
641 Equipment=1,FieldReplaceableUnit=SUP,EcPort=1
=================================================================================================================
cascadingOrder 0
ecBusRef EcBus=1
ecPortId 1
hubPosition NA >>> rubah dengan “set proxy hubPosition NA”
=================================================================================================================
Total: 4 MOs

6. Pada st field buat PositionRef pada SAU, SUP dengan cabinet=1, misal pada proxy SAU di st field adlah 334 :
get 334
set 334 positionRef Cabinet=1

X3453918G_CO> set 334 positionRef Cabinet=1

171201-00:06:49 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


Set positionRef on following 1 MOs ?
===================================================================================
334 Equipment=1,FieldReplaceableUnit=SAU
===================================================================================
Set positionRef on 1 MOs. Are you Sure [y/n] ? y

============================================================================================================
Id MO positionRef Result
============================================================================================================
334 FieldReplaceableUnit=SAU Cabinet=1 >>> Set.
============================================================================================================
Total: 1 MOs attempted, 1 MOs set
HASIL SAU

X3453918G_CO> get 334

171201-00:06:53 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/2556


=================================================================================================================
334 Equipment=1,FieldReplaceableUnit=SAU
=================================================================================================================
administrativeState 0 (LOCKED)
availabilityStatus i[1] = 1 (FAILED)
faultIndicator 1 (NOT_AVAILABLE)
fieldReplaceableUnitId SAU
hwTestResult Struct{0}
isSharedWithExternalMe
maintenanceIndicator 1 (NOT_AVAILABLE)
operationalIndicator 1 (NOT_AVAILABLE)
operationalState 0 (DISABLED)
positionCoordinates Struct{0}
positionInformation s[0] =
positionRef Cabinet=1
productData Struct{0}
reservedBy [0] =
specialIndicator t[0] =
statusIndicator 1 (NOT_AVAILABLE)
supportUnitRef [0] =
userLabel
=================================================================================================================
Total: 1 MOs

HASIL PADA SUP di SITE LAIN

3453339G_CO-JALAN_TIMOR_NUSANTARA_U21L18> get 632

171201-00:52:48 OFFLINE_3453339G_CO-JALAN_TIMOR_NUSANTARA_U21L18 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/7308


=================================================================================================================
632 Equipment=1,FieldReplaceableUnit=SUP
=================================================================================================================
administrativeState 1 (UNLOCKED)
availabilityStatus i[0] =
faultIndicator 2 (OFF)
fieldReplaceableUnitId SUP
hwTestResult Struct{0}
isSharedWithExternalMe
maintenanceIndicator 0 (NOT_APPLICABLE)
operationalIndicator 3 (STEADY_ON)
operationalState 1 (ENABLED)
positionCoordinates Struct{0}
positionInformation s[0] =
positionRef Cabinet=1
productData Struct{5}
>>> 1.productionDate = 20170314
>>> 2.productName = SUP 6601
>>> 3.productNumber = 1/BFL 901 009/4
>>> 4.productRevision = R2E
>>> 5.serialNumber = BR85343178
reservedBy [0] =
specialIndicator t[0] =
statusIndicator 0 (NOT_APPLICABLE)
supportUnitRef [0] =
userLabel
=================================================================================================================
Total: 1 MOs

7. Pada get cabinet=1 isi product data cabinet nya sesuai label SUP yg tertera, dgn command :

Set Cabinet=1 productdata productiondate=20170707,productname=SUP 6601,productnumber=103/BFL 901


009,productrevision=R1A,serialnumber=DB26035308

Pastikan cabinetIdentifier, productData, dan reservedBy telah terisi seperti contoh dibawah :
X3453918G_CO> get cabinet=1

171201-00:14:37 OFFLINE_X3453918G_CO 17.0f MSRBS_NODE_MODEL_17.Q1_309.32786.55_f84b stopfile=/tmp/4872


=================================================================================================================
283 Equipment=1,Cabinet=1
=================================================================================================================
cabinetId 1
cabinetIdentifier 1/BFL 901 009/4_BR85425854
climateRegulationSystem 0 (NOT_APPLICABLE)
climateSystem 0 (STANDARD)
positionRef
productData Struct{5}
>>> 1.productionDate = 20170707
>>> 2.productName = SUP 6601
>>> 3.productNumber = 103/BFL 901 009
>>> 4.productRevision = R1A
>>> 5.serialNumber = DB26035308
reservedBy [5] =
>>> reservedBy = Equipment=1,FieldReplaceableUnit=PDU-1
>>> reservedBy = EquipmentSupportFunction=1,Climate=1
>>> reservedBy = EquipmentSupportFunction=1,PowerDistribution=1
>>> reservedBy = EquipmentSupportFunction=1,PowerSupply=1
>>> reservedBy = Equipment=1,FieldReplaceableUnit=SUP
sharedCabinetIdentifier
smokeDetector false
userLabel
=================================================================================================================
Total: 1 MOs

8. Cek alarm harus clear yg berkaitan dengan :

Enclosure Product Data Mismacth


EcBus=1
EcPort=1

9. Buat CV dengan command "cvms DonePrecomm" dan restart dgn 2 2 0

Cara Setting BB Master - Slave dalam satu MU


1. Cek BB sebagai Master EC dgn get . supportsystem pastikan “true”
2. Cek get ecbus=1 pastikan sudah ter-create jika belum gunakan command dibawah sekaligus, akhiri dgn lt all

gs+
crn Equipment=1,EcBus=1
ecBusConnectionType EC
ecBusConnectorRef FieldReplaceableUnit=1
end
gs-

3. Cek get ecport=1 pastikan sudah ter-create jika belum gunakan command dibawah sekaligus, akhiri dgn lt all

gs+
crn Equipment=1,FieldReplaceableUnit=1,EcPort=1
cascadingOrder 0
ecBusRef EcBus=1
hubPosition X  sesuaikan port Master-nya
end
gs-
4. Cek get externalnode pastikan sudah ter-create jika belum gunakan command dibawah satu-satu, akhiri dgn lt all

cr Equipment=1,ExternalNode=1
cr Equipment=1,ExternalNode=1,EcPort=1
set Equipment=1,ExternalNode=1,EcPort=1 ecBusRef EcBus=1
set Equipment=1,ExternalNode=1,EcPort=1 hubPosition Y  sesuaikan port Slave-nya

5. Cek get ecport=1 pastikan “external node” sudah ter-create

6. Create CV

7. Pada BB sebagai SLAVE get . supportsystem pastikan “false”


8. Cek get ecport=1 pastikan sudah ter-create jika belum gunakan command dibawah sekaligus, akhiri dgn lt all

gs+
crn Equipment=1,FieldReplaceableUnit=1,EcPort=1
cascadingOrder 0
ecBusRef EcBus=1
hubPosition Y  sesuaikan port Slave-nya
end
gs-

9. Create CV
10. Cek alarm pastikan clear keduanya, jika belum siapkan Team Viewer dan Call Para Suhu Derajat terkait atau TAC