Professional Documents
Culture Documents
Firmware Upgrade Tool Duplex User Guide V1.08
Firmware Upgrade Tool Duplex User Guide V1.08
User Guide
TRACUT001
Version:[1.08]
Firmware_Upgrade_Tool_Duplex User Guide
Revision: 1.08
Date: 2017-09-19
Status: Release
General Notes
k
Queclink offers this information as a service to its customers, to support application and
n
engineering efforts that use the products designed by Queclink. The information provided is
i
based upon requirements specifically provided to Queclink by the customers. Queclink has
l l
not undertaken any independent search for additional relevant information, including any
c
information that may be in the customer’s possession. Furthermore, system validation of this
ia
product designed by Queclink within a larger electronic system remains the responsibility of
e t
the customer or the customer’s system integrator. All specifications supplied herein are
u
subject to change.
Q fide n
Copyright
This document contains proprietary technical information which is the property of Queclink
Wireless Solutions Co., Ltd. The copying of this document and giving it to others and the
using or communication of the contents thereof, are forbidden without express authority.
Offenders are liable to the payment of damages. All rights reserved in the event of grant of a
n
patent or the registration of a utility model or design. All specification supplied herein are
subject to change without notice at any time.
Co
TRACUT001 -1-
Firmware_Upgrade_Tool_Duplex User Guide
Contents
Contents ............................................................................................................................................ 2
Figure Index....................................................................................................................................... 3
0. Revision history ............................................................................................................................. 4
1. Tool Introduction ........................................................................................................................... 5
1.1.System Requirements ........................................................................................................... 5
1.2 Tool Interface ........................................................................................................................ 5
1.2.1.Introduction of the UI ................................................................................................. 5
2. Upgrade Operation Instruction ..................................................................................................... 9
k
2.1.Step1_Upgrade Prepare ....................................................................................................... 9
2.2.Step2_Upgrade Tool Basic Setting ........................................................................................ 9
i n
2.3.Step3_Device Prepare ........................................................................................................ 13
l l
2.3.1. Prepare for W series and GV75 ............................................................................... 13
c
2.3.2. Prepare for Other Devices ....................................................................................... 14
ia
2.4.Step4_Upgrade Process ...................................................................................................... 15
e t
2.5.Step5_Upgrade Success...................................................................................................... 24
2.6.Step6_Restart the device ................................................................................................... 24
u n
3. FQA.............................................................................................................................................. 25
3.1.COM_PORT_OPEN_FAIL ..................................................................................................... 25
Q fide
3.2.CHANGE_BAUDRATE_FAIL .................................................................................................. 26
3.3.INCORRECT_ROM_LOAD .................................................................................................... 27
3.4.DA_EXT_RAM_ERROR ........................................................................................................ 28
3.5.DOWNLOAD_DA_FAIL or BROM_CMD_JUMP_FAIL ........................................................... 29
n
3.6.Progress Bar Does Not Run................................................................................................. 29
Co
TRACUT001 -2-
Firmware_Upgrade_Tool_Duplex User Guide
Figure Index
k
FIGURE 8: UI OF BAUD RATE ................................................................................................................... 11
n
FIGURE 9: UI OF SELECTING OPTION ...................................................................................................... 12
i
FIGURE 10: UI OF STARTING UPGRADE FOR W SERIES AND GV75 ......................................................... 14
l l
FIGURE 11: UI OF STARTING UPGRADE................................................................................................... 15
c
FIGURE 12: UI OF DOWNLOAD DA.......................................................................................................... 16
ia
FIGURE 13 : UI OF DOWNLOAD BOOTLOADER ....................................................................................... 17
e t
FIGURE 14: UI OF PRE-FORMAT .............................................................................................................. 18
FIGURE 15: UI OF DOWNLOAD BIN......................................................................................................... 19
u n
FIGURE 16: UI OF ENTER META MODE IN UART ..................................................................................... 19
FIGURE 17: UI OF BOOT META IN BROM STAGE ..................................................................................... 20
Q fide
FIGURE 18: UI OF INIT CLEAR NV FILES ................................................................................................... 20
FIGURE 19: UI OF CLEAR NV SYS FILES .................................................................................................... 21
FIGURE 20: UI OF DOWNLOAD DA.......................................................................................................... 22
FIGURE 21: UI OF DOWNLOAD BIN......................................................................................................... 23
n
FIGURE 22: UI OF CONFIRM FM ............................................................................................................. 23
FIGURE 23: UI OF UPGRADE OK .............................................................................................................. 24
o
FIGURE 24: UI OF PORT ERROR............................................................................................................... 25
FIGURE 25: UI OF BAUD RATE ERROR ..................................................................................................... 26
C
FIGURE 26: UI OF UPGRADE WITH INCORRECT SCATTER FILE PATH ....................................................... 27
FIGURE 27: UI OF UPGRADE WITH INCORRECT SCATTER FILE ................................................................ 28
FIGURE 28: UI OF POWER SUPPLY OR USB ABNORMAL ......................................................................... 29
FIGURE 29: UI OF PROGRESS BAR DOES NOT RUN ................................................................................. 30
TRACUT001 -3-
Firmware_Upgrade_Tool_Duplex User Guide
0.Revision history
k
1.03 2016-01-20 Mark Sun 1.Add notices about GV75 firmware
upgrading.
n
1.04 2016-05-06 Leaf Ye 1. Add notice in “Step3_Power Off
l i
Device”: make sure the parameter
l
<Working Mode> in AT+GTURT function
c a
is set to “0” before upgrading.
e i
1.05 2016-09-02 Ella.huang 1. Update Chapter 2.2, recommend
t
“Load FW Files” firstly;
u n
1.06 2017-01-13 Happy.peng 1. Add notices about GV50 firmware
upgrading.
Q fide
1.07 2017-08-25 Una.Lu 1, Declare connect to external power
supply still when GV75 firmware
upgrading.
1.08 2017-09-19 Janet.He 1. Add upgrade difference between W
series and other devices.
o n
C
TRACUT001 -4-
Firmware_Upgrade_Tool_Duplex User Guide
1.Tool Introduction
1.1.System Requirements
The tool can run in PC without install, and the operation system must be in the list below:
Windows XP
k
Windows 7
n
Windows 8
i
Windows 10
cl a l
Any upgraded version of the tool will be informed in advance and provided by Queclink.
u e
1.2 Tool Interface
n t i
Q fide
1.2.1.Introduction of the UI
o n
C
TRACUT001 -5-
Firmware_Upgrade_Tool_Duplex User Guide
Basic Information
Select Area
Upgrade File
Show Area
i n k
l l
Progress Show
c a
and Control Area
u e n t i
Q fide
Figure 1: UI of the main interface
n
<Load FM Files>: This button used to select files to upgrade.
o
<COM Port>: It is the port connected device and PC.
C
<Baudrate>: It is baud rate for upgrade.
Note:
1. Suggest 460800 or above.
2. For GV50, there is no “baudrate” select area on the main interface.
<Start>/<Stop> button:
TRACUT001 -6-
Firmware_Upgrade_Tool_Duplex User Guide
Warning:
1. Click the Stop button to stop upgrading. But if the upgrade process is interrupted, there would
be no valid firmware in the module. So it is strongly recommended never to stop the firmware
upgrade process.
i n k
cl ia l
u e n t
Q fide
Figure 2: UI of Stop Upgrade
2. Please DO NOT remove download cable during downloading. This MAY cause the terminal
abnormal when upgrading GV300W/GV75W/GL300W.
o n
C
Figure 3: UI of Warning interface
TRACUT001 -7-
Firmware_Upgrade_Tool_Duplex User Guide
<Progress Bar>:
Indicate progress of upgrading process.
i n k
cl ia l
u e n t
Q fide
n
Figure 4: UI of Progress Bar
Co
TRACUT001 -8-
Firmware_Upgrade_Tool_Duplex User Guide
2.1.Step1_Upgrade Prepare
k
Each device type has its own upgrade
n
Upgrade Cable cable.
i
2 Upgrade Cable
l l
for device Note: Please make sure upgrade cable
c
always connect to PC.
ia
Make sure Queclink will provide driver base on
e t
cable can be device type. But driver also would be
3 Driver
u n
identified by found automatically in WIN 7 or above
PC. system after insert upgrade cable to PC.
Q fide
Getting from Queclink.
Note:
Firmware for
3 Firmware File Normally we will compress the firmware
upgrade.
file to you. But please make sure
n
decompress this file.
o
Please refer to Chapter 0 system
4 Computer PC for short
requirements.
C
Queclink_Firmware
5 Upgrade tool Getting from Queclink.
_Upgrade_Tool_Duplex
In this step, please make sure the upgrade cable connect to the PC first. And now, open
Queclink_Firmware_Upgrade_Tool_Duplex and configure basic information in tool, including
<Load FW Files>,<COM Port>, <Baudrate> and <option>.
TRACUT001 -9-
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 5: UI of Load FW Files
o n
C
Figure 6: UI of After Load FW Files
TRACUT001 - 10 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e t
Figure 7: UI of Port
Q fide n
o n
C
Figure 8: UI of Baud rate
TRACUT001 - 11 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t Figure 9: UI of Selecting option
Q fide
Note:
1. The first time to open the tool there is no option and showing error reminder, should
load the Selecting FW Files.
2. For GV200 and GV75, the highest baud rate is 460800.
n
3. Don’t have COM port and baudrate option if USB download.
4. For W series and GV75, Select the COM port according to chapter 2.3.1.
o
5. “Option” setting will be hiding if no need.
C
TRACUT001 - 12 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
e t
2.3.Step3_Device Prepare
u n
For the device prepare, these is a little different between W series/GV75 and other devices.
Q fide
Please see the details as below.
n
Select the COM Port.
o
Click “Start” button in Queclink_Firmware_Upgrade_Tool_Duplex.
C
TRACUT001 - 13 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide Figure 10: UI of Starting Upgrade for W series and GV75
n
NOTE:
o
Make sure the parameter <Working Mode> in the AT+GTURT command is set to “0” before
upgrading GV75.
C
2.3.2. Prepare for Other Devices
TRACUT001 - 14 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 11: UI of Starting Upgrade
n
Note:
o
For GL500, need to connect the device to upgrade cable, and then install battery in.
For GV200/GV200G/GV200N, need to connect external power supply after upgrade cable
C
connected.
2.4.Step4_Upgrade Process
There are several steps in the progress of upgrading firmware when has chosen the option
of Upgrade Firmware and Clear User Data .
Download DA
Download Bootloader
Pre-Format
Download Bin
Enter meta mode in uart
Boot meta in brom stage
TRACUT001 - 15 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
o n Figure 12: UI of Download DA
C
TRACUT001 - 16 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 13 : UI of Download Bootloader
o n
C
TRACUT001 - 17 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 14: UI of Pre-Format
o n
C
TRACUT001 - 18 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 15: UI of Download Bin
o n
C
Figure 16: UI of Enter meta mode in uart
TRACUT001 - 19 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 17: UI of Boot meta in brom stage
o n
C
Figure 18: UI of Init clear nv files
TRACUT001 - 20 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 19: UI of Clear Nv Sys Files
There are several steps in the progress of upgrading firmware when has chosen the option
of Upgrade Firmware Upgrade Firmware Only.
n
Download DA
o
Download Bin
Confirm FM
C
Dialogue frames are shown in Figure 13 : UI of Download Bootloader, Figure 14: UI of Pre-Format,
Figure 15: UI of Download Bin
TRACUT001 - 21 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 20: UI of Download DA
o n
C
TRACUT001 - 22 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 22: UI of Confirm FM
o n
C
TRACUT001 - 23 -
Firmware_Upgrade_Tool_Duplex User Guide
2.5.Step5_Upgrade Success
i n k
cl ia l
u e n t
Q fide Figure 23: UI of Upgrade OK
o n
C
2.6.Step6_Restart the device
After finishing the upgrade, disconnect the upgrade cable or external power supply to power
off the device.
Then power on the device and you can configure the device now.
Note:
For GV50,if you choose the option of Upgrade FM and Clear User Data, the device will power
on automatically after finishing the upgrade
TRACUT001 - 24 -
Firmware_Upgrade_Tool_Duplex User Guide
3.FQA
3.1.COM_PORT_OPEN_FAIL
i n k
cl ia l
u e n t
Q fide
o n Figure 24: UI of Port ERROR
C
Possible Reason Solution
COM port is occupied by other tools, this tool cannot open Release this COM in other
COM. tools.
Upgrade cable is not connected. Connect cable to PC.
This COM port is dead. Reboot PC.
TRACUT001 - 25 -
Firmware_Upgrade_Tool_Duplex User Guide
3.2.CHANGE_BAUDRATE_FAIL
i n k
cl ia l
u e n t
Q fide Figure 25: UI of Baud rate ERROR
n
Possible Reason Solution
o
Baud rate is not supported by environment. Change baud rate, and try again.
C
TRACUT001 - 26 -
Firmware_Upgrade_Tool_Duplex User Guide
3.3.INCORRECT_ROM_LOAD
i n k
cl ia l
u e n t
Q fide Figure 26: UI of Upgrade with Incorrect Scatter File Path
o n
Possible Reason Solution
Wrong scat file path select. Correct the scat file path.
C
TRACUT001 - 27 -
Firmware_Upgrade_Tool_Duplex User Guide
3.4.DA_EXT_RAM_ERROR
i n k
cl ia l
u e n t
Q fide Figure 27: UI of Upgrade with Incorrect Scatter File
n
Possible Reason Solution
o
Wrong scat file select. Correct the scat file.
C
TRACUT001 - 28 -
Firmware_Upgrade_Tool_Duplex User Guide
3.5.DOWNLOAD_DA_FAIL or BROM_CMD_JUMP_FAIL
i n k
cl ia l
u e n t
Q fide Figure 28: UI of Power supply or USB Abnormal
o n
Possible Reason Solution
Power supply is unstable. Obtain stable power supply.
C
USB abnormal Change PC or upgrade cable to obtain stable COM port
communication.
Follow the standard steps, in step 0, progress bar does not run in this step.
TRACUT001 - 29 -
Firmware_Upgrade_Tool_Duplex User Guide
i n k
cl ia l
u e n t
Q fide
Figure 29: UI of Progress Bar Does Not Run
n
Serial port problem 1) Make sure COM Port is available or try to change
another valid COM Port;
o
2) Reboot PC and try to upgrade once more.
C
TRACUT001 - 30 -