PRODUCT TYPE

PERFORMANCE CURVE CP3085.182 HT


DATE PROJECT CURVE NO ISSUE
2003-03-19 53-250-00-2450 2
1/1-LOAD 3/4-LOAD 1/2-LOAD RATED IMPELLER DIAMETER
POWER ..... 2.4 kW 132 mm
POWER FACTOR 0.92 0.90 0.84 STARTING
EFFICIENCY 80.0 % 82.0 % CURRENT ...
82.0 % RATED 27 A MOTOR # STATOR REV
MOTOR DATA --- --- --- CURRENT ... 4.7 A 15-09-2AL 39D 10
COMMENTS INLET/OUTLET RATED FREQ. PHASES VOLTAGE POLES
SPEED ..... 2830 rpm
- / 80 mm TOT.MOM.OF 50 Hz 3 400 V 2
IMP. THROUGHLET INERTIA ... 0.010 kgm2 GEARTYPE RATIO
NO. OF
40 mm BLADES 1 --- ---

[kW]

SHAFT POWER
INPUT POWER
3.0
POWER

2.5

O
*
G

2.0

OVERALL EFF.
PUMP EFF.
1.5

DUTY-POINT FLOW [l/s] HEAD [m] POWER [kW] EFF. [%] NPSH [m] GUARANTEE

O
*
B.E.P. 9.24 14.4 2.66 ( 2.16) 49.1 (60.4) 4.1 ISO 9906/annex A.2
NPSH RE
[m]

BEST EFF. POINT


[m]
Curva de
Estrangulamiento
25
de la Bomba. 12.5

Curva de EFF.
20 NPSH 10.0 [%]
HEAD

15 7.5 60
Eficiencia de
Eje. 50

10 5.0 40

30
NPSH RE=11 m
5 Eficiencia de 2.5 20
Entrada.
10

0 0.0 0
0 4 8 12 16 20 [l/s]
FLOW

GUARANTEE BETWEEN LIMITS (G) ACC. TO

Performance with clear water and ambient temp 40 °C ISO 9906/annex A.2