Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TECHNICAL PROJECTS CONSULTANTS PVT. LTD.

CANTILEVER SLAB DESIGN


PROJECT : SGC-BLOCK-A Ground Floor Roof SLAB MARK : S16/CS3
DESIGN DATA
Cantilver Length (from support face to free end) = 1.8 m
Characterstic Strength of Concrete (f ck) = 25 N/mm
2

Characterstic Strength of Steel (f y) = 500 N/mm


2

Clear Cover = 20 mm
Assumed Depth = 200 mm

Dead Load of Slab = 5.00 KN/m


2

Floor Finish 50 mm = 1.20 KN/m


2

Sunk 50 mm = 1.00 KN/m


2

Live Load = 3.00 KN/m


2

Total Load (w) = 10.20 KN/m


2

Prapet/Railing Load(P) = 3.00 KN/m


DESIGN
Provided Effective Depth dxprov. = 174 mm
Effective Span = 1.887 m
Factored Bending Moment at Support = 35.73 KN/m
Factored Shear = 33.37 KN
Effective Depth Required (d) = 101.77 mm
Required Overall Depth (D) = 127.77 mm
DEPTH CHECK OK
Main bar at Distribution
Reinforcement Calculation support Reinforceme
Area of Steel Required Ast 502 nt
240 mm
2

Dia of Reinforcement 12 8 mm
Spacing of Reinforcement bars Required 225 209 mm
Spacing of Reinforcement bars Provided 150 200 mm
Area of Steel Provided Ast 753.98 251.33 mm
2

CHECK FOR DEFLECTION


Area of c/s of steel required 2
f s =0.58*f y * = 193 N/m IS 456, Fig. 4
Area of c/s of steel provided
Basic span/eff depth ratio for cantilever slab = 7
Modification factor = 1.61
Coefficient for max ratio of span/eff depth = 11
Effective Depth required = 167 < 174 mm SAFE
Overall Depth required = 193 < 200 mm SAFE

UDL = 1.08444 mm
Elastic Deformation
POINT = 0.45074 mm
Total Elastic Deformation = 1.5352 mm
Permanent Deflection = 3.0703 mm
Permissible Deflection = 7.5480 mm SAFE
CHECK FOR SHEAR
Factored Shear (Vu) = 33.37 kN
tv = Vu/bd = 0.19 N/mm2
Percentage of Tnsion Steel (pt) = 0.43 %
b = 6.70 [As per SP_16, b=0.8*fck/(6.89*pt)], but not less than 1
tcmax = 0.46 N/mm2 [As per SP_16, tc=[0.85*root(0.8*fck)*root(1+5b)-1]/(6*b)
k = 1.20 (As per IS:456:2000:40.2.1.1)