CURVE INSPECTION REGISTER

Section/Station : Chaparmukh Jn-Lumding Jn Line : SL

Curve No. : 84

From : 119 135 m To : 119 385 m

Degree of Curve : 2.25

Station Design Design Details of Inspection 21/06/2019 Details of Inspection


No Versine SE V SE G V SE G
-3 0 0 5

-2 0 0 5

-1 0 0 3

0 0 0 0 0 5

1 11 11 10 -10 5

2 23 22 21 -21 3

3 35 33 34 -32 5

4 46 44 44 -44 5

5 55 55 52 -53 3

6 65 65 64 -65 5

7 64 65 63 -64 2

8 64 65 62 -64 5

9 64 65 62 -64 5

10 64 65 63 -64 3

11 64 65 63 -64 5

12 64 65 63 -64 4

13 64 65 63 -64 5

14 64 65 63 -64 5

15 64 65 63 -64 4

16 64 65 63 -64 5

17 64 65 63 -64 5

18 64 65 63 -64 3

19 65 65 63 -64 5

20 55 55 54 -54 3

21 46 44 45 -44 4

22 35 33 34 32 5

23 23 22 22 -21 5

24 11 11 10 -10 5
Station Design Design Details of Inspection 21/06/2019 Details of Inspection
No Versine SE V SE G V SE G
25 0 0 2 -4 5

26 0 0 5

27 0 0 5

28 0 0 5

Realignment Required :-

Adequacy of Ballast :- Yes

Remarks :-

Inspecting offical :- jitendra mahato

Designation :- SE/P.Way/CPK/East

Entry Date :- 29/06/2019 13:26

Date Remarks Date Remarks


Compliance :-
CURVE INSPECTION REGISTER

Section/Station : Chaparmukh Jn-Lumding Jn Line : SL

Curve No. : 85

From : 120 556 m To : 121 106 m

Degree of Curve :3

Station Design Design Details of Inspection 21/06/2019 Details of Inspection


No Versine SE V SE G V SE G
-3 0 0 5

-2 0 0 5

-1 0 0 5

0 0 0 0 0 5

1 7 13 5 11 5

2 15 26 14 24 5

3 23 39 21 38 2

4 31 52 30 51 5

5 39 65 38 64 5

6 47 78 45 76 5

7 55 91 54 90 5

8 64 104 63 102 5

9 72 117 71 115 5

10 80 130 80 129 5

11 86 140 84 141 3

12 86 140 84 141 5

13 86 140 84 141 5

14 86 140 84 141 3

15 86 140 84 141 5

16 86 140 84 141 4

17 86 140 84 141 4

18 86 140 84 140 5

19 86 140 85 141 3

20 86 140 84 139 5

21 86 140 84 139 5

22 86 140 84 141 3

23 86 140 84 141 5

24 86 140 84 141 5
Station Design Design Details of Inspection 21/06/2019 Details of Inspection
No Versine SE V SE G V SE G
25 86 140 84 141 3

26 86 140 84 139 5

27 86 140 84 139 5

28 86 140 84 139 4

29 86 140 84 139 5

30 86 140 84 139 5

31 86 140 84 139 5

32 86 140 84 140 5

33 86 140 84 139 3

34 86 140 84 139 5

35 86 140 86 140 5

36 86 140 86 140 6

37 86 140 86 140 5

38 86 140 86 140 5

39 86 140 85 141 4

40 86 140 85 142 5

41 86 140 86 140 3

42 86 140 86 140 5

43 86 140 85 140 4

44 86 140 85 140 4

45 80 130 79 131 5

46 72 117 73 118 5

47 64 104 65 105 3

48 55 91 56 92 5

49 47 78 48 80 5

50 39 65 40 66 3

51 31 52 31 53 5

52 23 39 24 40 4

53 15 26 16 27 5

54 7 13 8 14 5

55 0 0 2 3 5

56 0 0 0

57 0 0 0

58 0 0 0
Realignment Required :-

Adequacy of Ballast :- Yes

Remarks :-

Inspecting offical :- jitendra mahato

Designation :- SE/P.Way/CPK/East

Entry Date :- 29/06/2019 13:38

Date Remarks Date Remarks


Compliance :-