V200R005C01
Installation Guide
Issue 03
Date 2008-07-10
Part Number 00357932
Website: http://www.huawei.com
Email: support@huawei.com
and other Huawei trademarks are the property of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but the statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Contents
3 Installing Hardware...................................................................................................................3-1
3.1 Hardware Connection......................................................................................................................................3-2
3.2 Installing a Computer......................................................................................................................................3-2
3.3 Connecting Equipment Cables........................................................................................................................3-3
3.4 Checking the Hardware Installation................................................................................................................3-4
9 FAQ...............................................................................................................................................9-1
9.1 How to Enable the Telnet Authority of User root...........................................................................................9-3
9.2 How to Enable the FTP Authority of User root..............................................................................................9-3
9.3 How to Check Whether Sybase Service Process Is Started............................................................................9-3
9.4 How to Modify the License of Sybase............................................................................................................9-4
9.5 How to Manually Start the Database Server...................................................................................................9-4
9.6 How to Manually Shut Down the Database Server.........................................................................................9-4
9.7 How to Check Whether the T2000 Server Is Started on UNIX......................................................................9-5
9.8 How to Shut Down T2000 Server on UNIX...................................................................................................9-5
9.9 How to Shut Down the Workstation...............................................................................................................9-6
9.10 How to Enable the Northbound Interface......................................................................................................9-7
9.11 Identifying Network Card Name...................................................................................................................9-7
9.12 How to Change the IP Address.....................................................................................................................9-8
9.13 How to Change the Host Name.....................................................................................................................9-9
9.14 About Time Zones.........................................................................................................................................9-9
9.15 Command Failure Caused by an Improper Terminal Windows Size..........................................................9-11
B Disk Mirror................................................................................................................................B-1
B.1 Creating Disk Mirror......................................................................................................................................B-2
B.2 Common Operations About Disk Mirrors.....................................................................................................B-3
B.2.1 Checking the Configuration and Status of the State Database Replica................................................B-4
B.2.2 Checking Mirror Configurations...........................................................................................................B-4
B.2.3 Checking the Mirror Status................................................................................................................... B-5
B.2.4 Creating a State Database Replica........................................................................................................B-5
B.2.5 Deleting State Database Replica........................................................................................................... B-5
B.2.6 Creating Mirrors and Submirrors..........................................................................................................B-6
B.2.7 Creating Mirror root..............................................................................................................................B-6
B.2.8 Clearing Submirrors or Mirrors............................................................................................................B-6
Figures
Tables
Purpose
The document describes how to install the T2000 and provides guides to obtain the reference
information of the T2000 installation..
Related Versions
The following table lists the product versions related to this document.
Intended Audience
The intended audience of this document are:
Organization
This document is organized as follows.
Chapter Description
Chapter Description
4 Installing the T2000 on UNIX This chapter describes how to install the
T2000 on Solaris 10.
5 Installing the T2000 on Windows This chapter describes how to install the
T2000 on Windows.
A Obtaining and Installing a T2000 This chapter describes how to obtain and
License install a T2000 license.
E Setting Alarm Forwarding to External This chapter describes how to forward alarms
Systems to an external system by using email or short
messages.
Conventions
Symbol Conventions
The following symbols may be found in this document. They are defined as follows.
Symbol Description
General Conventions
Convention Description
Boldface Names of files, directories, folders, and users are in boldface. For
example, log in as user root.
Command Conventions
Convention Description
GUI Conventions
Convention Description
Boldface Buttons, menus, parameters, tabs, window, and dialog titles are in
boldface. For example, click OK.
> Multi-level menus are in boldface and separated by the ">" signs. For
example, choose File > Create > Folder.
Keyboard Operation
Format Description
Key Press the key. For example, press Enter and press Tab.
Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt+A means the
three keys should be pressed concurrently.
Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means the two keys
should be pressed in turn.
Mouse Operation
Action Description
Click Select and release the primary mouse button without moving the pointer.
Double-click Press the primary mouse button twice continuously and quickly without
moving the pointer.
Drag Press and hold the primary mouse button and move the pointer to a certain
position.
Update History
Updates between document versions are cumulative. Therefore, the latest document version
contains all updates made to previous versions.
This chapter is added to describe how to install a T2000 plug-in (which is used to support the
NG WDM or RTN equipment) on UNIX and Windows.
1 Installation Process
This chapter describes the process for installing the T2000 system.
The following is the explanation for frequently used terms during the installation process.
l Server: It can refer to either the hardware or the software. When we refer to the client/server
architecture, the server here refers to the server application, which is the software. Usually,
the computer that runs the server application is also called a server, which is the hardware.
l Client: It can refer to either the hardware or the software. When we refer to the client/server
architecture, the client here refers to the client application, which is the software. The client
application can either run on the same computer with server application, or separately run
on another computer. Usually, the computer that runs the client application is also called a
client, which is the hardware.
l Workstation, host: In this manual, the workstation is the same as the host. Both of them
refer to the computer that runs the UNIX system.
The T2000 software includes the server program and the client program. You can install the
T2000 software on the same or separate computers using either of the following two ways:
l Installing the server/client system together: Install both the T2000 server program and the
client program on the same computer.
l Installing the server/client system separately: Install the T2000 server program on one
computer and the client program on another.
The T2000 software can be installed on both the UNIX and Windows platforms. Table 1-1
shows the supported operating systems.
NOTE
2 Installation Preparations
Before you install the T2000 system, make sure that the preparations for the software, hardware
and environment are done.
Based on different network scales and application environments, you can choose different
configurations during the installation. The T2000 server can run on both the UNIX and Windows
platforms. Table 2-1 and Table 2-2 list the recommended configuration for the server on UNIX
and Windows platforms respectively.
Fujitsu PW650
The T2000 client can be installed and run on both UNIX and Windows platforms and the latter
one is recommended. The minimum configuration for the T2000 client is shown in Table 2-3.
Context
CAUTION
l If the server computer has multiple network cards, you only need to obtain a license for the
network card used by the T2000 server.
l Do not make any modifications to the license file. Otherwise, the license will fail.
Procedure
Step 1 Obtain the contract number in project documents.
Step 3 Send the contract number and the MAC address to a Huawei engineer or the nearest branch.
Step 4 The Huawei engineer will fill in the application form and mail it to the License Center to obtain
a T2000 license.
NOTE
For details about how to obtain a license, refer to A.2 Obtaining a T2000 License.
----End
Procedure
Step 1 Read the engineering documents to learn the related network planning, floor plan, detailed
construction drawing and cabling diagram.
Step 2 Read manuals of the equipment to learn the precautions for the installation.
Step 3 Read this document to learn the details of installation.
----End
Procedure
Step 1 Check whether the packing cases are damaged. Ensure that the equipment is not placed upside
down during the transportation and that the place of delivery agrees with the actual installation
place.
Step 2 Unpack the packing cases and inspect the goods. Check and accept the articles piece by piece
carefully with reference to the name, type and quantity of the articles stated on the Packing
List.
----End
Postrequisite
If you find that there is any item missing or the equipment is damaged, contact Huawei in time
to check whether the installation could be proceeded.
Procedure
Step 1 Prepare the following general tools:
l Measuring tool, such as long tape, ruler, angle square and industrial horizontal ruler.
l Marking tool, such as marking pen and ink fountain.
l Drilling related tools, such as percussion drill and vacuum cleaner.
l Fastening tool, such as straight screwdriver, cross screwdriver, adjustable wrench, socket
wrench, double offset ring wrench, and long-arm wrench.
l Small tool, such as sharp-nose pliers, diagonal pliers, pincer pliers, hand-held electric drill,
file, handsaw, crowbar, rubber hammer, and horn hammer.
l Auxiliary tool, such as tweezers, brush, paper knife, plumb, electric iron, solder wires, and
electric outlet.
Step 2 Prepare some special tools including earth resistance tester, ESD wrist strap, golve, cable peeler,
clamp pincer, RJ-45 crimping pliers and cable cutter.
Step 3 Prepare related instruments, including multimeter and 500 V megohmmeter (used to test the
insulation resistance).
NOTE
The instruments must pass the calibration test.
----End
Procedure
Step 1 Ensure that there is enough space to place a computer.
l The back of the computer must be at least 8 cm away from other objects to ensure good
ventilation.
l Put the server computer into a cabinet.
l If no cabinet is available, provide a desk that is stable and large enough to place the computer,
keyboard, mouse and other necessary devices.
Step 2 Refer to relevant computer specifications to verify that the temperature and humidity within the
equipment room meet the requirements.
NOTE
Usually, the required temperature is 15℃–30℃ and the humidity is 40%–75%.
Step 3 Verify that other ambient requirements, such as the cleanness, density of corrosive gas,
electromagnetic environment and lightning protection, meet the requirements of a telecom
equipment room.
Step 4 Ensure that a minimum of 2 Mbit/s communication bandwidth between the T2000 client and
server is provided and the packet loss ratio is lower than 0.1%.
----End
Procedure
Step 1 Ensure that there is enough power supply to power on a workstation.
The power consumption requirements for the commonly used SUN workstations are listed in
Table 2-4.
----End
Procedure
Step 1 Check the Solaris 10 installation disk. The disk shipped with the product can either be DVD (1
piece) or CD-ROMs. The CD-ROMs must include the following:
l Solaris 10 Software 1 (01/06 SPARC Platform Edition)
l Solaris 10 Software 2 (01/06 SPARC Platform Edition)
l Solaris 10 Software 3 (01/06 SPARC Platform Edition)
l Solaris 10 Software 4 (01/06 SPARC Platform Edition)
Step 2 Check the T2000 installation CD-ROMs or the installation software packages, which must
include the following:
l T2000 for UNIX installation CD-ROM #1 (System patches CD-ROM) or installation
software package: t2000v200r005c01b0xx_unix_cd1.tar
l T2000 for UNIX installation CD-ROM #2 (T2000 application CD-ROM) or installation
software package: t2000v200r005c01b0xxen_unix_cd2.tar
l T2000 for UNIX installation CD-ROM #3 (Tool software CD-ROM) or installation software
package: t2000v200r005c01b0xx_unix_cd3.tar
----End
NOTE
The space of slice 4 is fixed to 30 MB without a mount point. Disk mirror cannot be created without slice
4.
NOTE
The IP addresses and network card name displayed in Table 2-6 are examples. The installation program
automatically identifies the name during the installation. You can change these values based on actual
situations.
Procedure
Step 1 The computer name must be the combination of English letters and digits.
NOTE
l Ensure that the first character is a letter and no space is included in the name.
l If the server and client software is installed on the same computer, the recommended computer name
is T2000.
l If the server and client software is installed on separate computers, the following host naming
specifications are recommended.
Server PC: T2000; Client PC: T2000clientn.
Here, n is the serial number of different clients.
Step 2 Ensure that a user with the Administrator authority has been created.
Step 3 In order to have a better display effect after installation, the display mode of the computer should
be modified as: 1024 x 768 pixels, High Color, 16 bit enhanced color or more.
----End
Procedure
Step 1 Verify that the Windows XP Professional or Windows Server 2003 Standard Edition, and their
corresponding patches is installed. To be specific, Service Pack 2 should be installed for
Windows XP, and Service Pack 1 should be installed for Windows 2003.
NOTE
For the installation of the Windows operating system and its patches, refer to the CD-ROM of Windows
installation and related materials.
TIP
To confirm whether the SP2 patch has been installed in the Windows XP operating system, right-click My
Computer, and choose Properties from the shortcut menu. If there is Service Pack x in the System
Properties list in the General tab, it indicates that Service Pack x is installed.
----End
CAUTION
By default, the T2000 is installed in the C:\T2000 directory. Hence, ensure drive C has enough
space.
D: 40 GB Other usage.
3 Installing Hardware
A maximum of 32 clients can access one server and be operated on at the same time. The number
of clients accessed to one server is related to not only the authority assigned by the license but
also the hardware of the server.
NOTE
The client/server structure refers to a structure where multiple terminals are connected with the server
through LAN or WAN. Users can operate on the clients, while a set of data saved on the server is shared
networkwide. The client of the T2000 implements the workstation function of TMN for users to operate
and manage the transmission network. The server of the T2000 implements the operating system function
of TMN, saving network data and providing various management functions for the transmission network.
Prerequisite
The operation desk or the cabinet must be prepared.
Context
NOTE
If you want to install the computer in the dedicated cabinet, follow the attached instructions of the cabinet.
The following procedure describes how to install a computer on an operation desk.
Procedure
Step 1 Choose a proper operation desk according to the computer model. For details about the
dimensions of the commonly used SUN workstations, refer to Table 3-1.
Step 2 Place the host of the computer on top of the operation desk at the left side.
Step 3 Mount the monitor to the base and place it on top of or beside the host. The right side of the
operation desk is reserved for a printer.
Step 4 Properly connect the monitor cable, monitor power cable, host power cable, keyboard, mouse
and network cables.
Step 5 If other peripherals, such as tape drive, external CD-ROM and external hard disk, are required,
properly connect them following the corresponding instructions. Place these peripherals on the
operation desk.
Step 6 Follow the corresponding instructions to install the printer. Upon completion, check whether
the printer works normally.
----End
Prerequisite
The T2000 computer must be correctly installed.
Procedure
Step 1 Replace the power cable core of the T2000 computer with the grounding cable that is specifically
delivered to ground the T2000 computer. Connect one end of the grounding cable to the
grounding conductor of the T2000 computer, and the other end to the protection grounding bar
in the equipment room or to the casing earth PGND of the transmission equipment.
NOTE
l Generally, at the network interface side of the T2000 computer, there is a dedicated grounding screw
with a grounding mark . If there is not such a grounding screw, ground the cable to a place (on the
T2000 computer cabinet) that is equivalent to earth. The grounding cable of the T2000 computer should
be routed under the antistatic floor, and then be connected to the protection grounding bar in the
equipment room or to the casing earth PGND of the transmission equipment.
l If the computer uses UPS for power supply, the shell of the UPS should be connected to the PGND
connectors of the equipment room or the PGND of the transmission equipment chassis. The AC ground
wire (PE) must be disconnected.
Step 2 Connect the network cable to the network interface of the T2000 computer.
Step 3 Check whether the network connection is normal.
CAUTION
Before plugging or unplugging the serial/parallel port cable for the computer, make sure to power
off the computer.
----End
Prerequisite
The computer installation and all equipment cable connections must be complete.
Procedure
Step 1 Check the power cables and grounding cables for each component. Make sure that these cables
are connected to the correct poles in a safe and proper manner.
Step 2 Properly bound all cables without damaging the cable surface.
Step 3 Check the hardware connection cables and network cables according to the hardware connection
diagram.
Step 4 Check the plugs and sockets.
l Make sure that the locker of each cable is secured. For a coaxial cable, make sure that the
rotary plug is tightly fastened.
l Check whether there are any missing pins, bent pins, or short circuits on each socket.
Step 5 Do not leave cable straps, stubs, or desiccant bags on the installation site. Keep all parts on the
site neat and clean.
Step 6 Remove unnecessary objects from the equipment room. Objects in the equipment room should
be placed orderly. Keep the operation desk and the movable floor neat and clean.
----End
Result
After checking the hardware installation, you can power on the computer.
If a SUN workstation is used, you should turn the rotary switch beside the power supply to the
normal position (I) before powering on the workstation. See Figure 3-2.
This chapter describes how to install the T2000 on UNIX (Solaris 10).
Prerequisite
The hardware such as the workstation is correctly connected and is normally started.
4.1 Installing the Operating System
You can install the Solaris 10 operating system.
4.2 Preconfiguration for Installation
The preconfiguration tasks for installation include the installation of the HWICMR software
package, the installation of Solaris 10 patches, and relevant configurations.
4.3 Installing the T2000
You can install the T2000 on UNIX.
4.4 Installing the T2000 License
You can install the T2000 license on UNIX.
4.5 Creating Shortcut Icons
By creating icons for the T2000 client and server programs, you can start the T2000 in an easier
way.
4.6 Enabling the Northbound Interface (Optional)
To connect the T2000 to an NMS/OSS, you must enable the corresponding northbound interface,
such as CORBA, MML and SNMP.
4.7 Creating a Disk Mirror (Optional)
You can create a disk mirror.
4.8 Verifying the Installation
After you install the T2000, you need to check directories, user, the running status of databases
and the running status of the T2000.
Context
NOTE
The following procedure describes how to use CD-ROMs to install Solaris 10. To install the Solaris 10 by
using the DVD (only one piece), you can refer to this procedure.
Procedure
Step 1 Start the workstation.
Step 3 Insert the CD/DVD for Solaris 10 Software 1 (01/06 SPARC Platform Edition). Run the
following command at the ok prompt to restart the system:
boot cdrom
In about five minutes, the system prompts you to select the language for installation.
Step 4 Enter 0 to select English as the language for installation and then press Enter.
The Welcome dialog box is displayed.
l This dialog box is not displayed on the computer that has only one network card.
l Usually, it is recommended that you select the first option.
l To identify the network port corresponding to the name of each network card, refer to 9.11 Identifying
Network Card Name after the operating system is successfully installed.
Step 9 Enter the host name that is previously planned, for example, T2000. Click Next.
The IP Address dialog box is displayed.
Step 10 Enter the IP address that is previously planned, for example, 129.9.1.1. Click Next.
The Netmask dialog box is displayed.
Step 11 Enter the confirmed subnet mask 255.255.255.0 and click Next.
The IPv6 dialog box is displayed.
Step 18 Set the region and time zone correctly, and click Next.
The Date and Time dialog box is displayed.
Step 20 Enter rootkit, the password of user root twice and click Next.
NOTE
rootkit is the default password for the super user root. After installing the OS, change the default password
immediately through GUI or command line. The password should not be less than eight characters.
The Confirm Information dialog box is displayed.
Step 23 Select Yes in the Reboot automatically after software installation? field and select Yes in the
Eject a CD/DVD automatically after software installation? field, and then click Next.
The Specify Media dialog box is displayed.
If the Select Upgrade or Initial install dialog box is displayed, the system is upgradeable. If a backup of
the previous Solaris version is not needed, select Initial Install and click Next.
If the Pausing dialog box is displayed during the installation, click Continue.
After the system restarts, the Do you need to override the system's default NFS version 4
domain name (yes/no)? dialog box is displayed.
Step 40 Enter no, and press Enter.
The Specify Media dialog box is displayed.
Step 41 Select CD/DVD to specify the media from which to install Solaris 10 Software 2 for SPARC
Platform, and click Next.
The system automatically ejects the Solaris 10 Software 1 (01/06 SPARC Platform Edition)
disk.
Step 42 Insert the CD/DVD for Solaris 10 Software 2 (01/06 SPARC Platform Edition), and then click
OK.
The Ready to Install dialog box is displayed.
Step 44 Select CD/DVD to specify the media from which to install Solaris 10 Software 3 for SPARC
Platform, and click Next.
The system automatically ejects the Solaris 10 Software 2 (01/06 SPARC Platform Edition)
disk.
Step 45 Insert the CD/DVD for Solaris 10 Software3 (01/06 SPARC Platform Edition), and then click
OK. The Ready to Install dialog box is displayed.
The Specify Media dialog box is displayed.
Step 46 Select CD/DVD to specify the media from which to install Solaris 10 Software 4 for SPARC
Platform, and click Next.
The system automatically ejects the Solaris 10 Software 3 (01/06 SPARC Platform Edition)
disk.
Step 47 Insert the CD/DVD for Solaris 10 Software 4 (01/06 SPARC Platform Edition), and then click
OK.
The Ready to Install dialog box is displayed.
----End
Procedure
Step 1 Log in to the system as user root. Insert the T2000 for UNIX installation CD-ROM #1 (System
patches CD-ROM) or prepare the installation package:
t2000v200r005c01b0xx_unix_cd1.tar.
TIP
If the installation software package needs to be transferred by FTP, run the following commands first to
enable the FTP function for user root.
# sed "/^root/s//#root/g" /etc/ftpd/ftpusers > /tmp/ftpusers
# cp /tmp/ftpusers /etc/ftpd/ftpusers
Then transfer the software package to the /export directory in the bin mode.
Step 2 Run the following command in the terminal window and enter the installation path:
# cd /cdrom/cdrom0
NOTE
To install the software from the hard disk, run the following commands to uncompress the installation
package and navigate to the installation directory:
# cd /export
# tar xvf t2000v200r005c01b0xx_unix_cd1.tar
# cd disk1
NOTE
The value of the key fingerprint is displayed according to the actual situation.
Your identification has been saved in //.ssh/id_rsa.
Your public key has been saved in //.ssh/id_rsa.pub.
The key fingerprint is:
05:28:0f:03:c5:19:35:27:33:4e:53:f0:ab:47:3e:52 root@T2000
......
Installing the HWICMR software...
x HWICMR, 0 bytes, 0 tape blocks
x HWICMR/conf, 0 bytes, 0 tape blocks
x HWICMR/conf/locales, 0 bytes, 0 tape blocks
x HWICMR/conf/locales/C, 0 bytes, 0 tape blocks
......
The HWICMR software has been installed successfully.
Installing the T2000 agent for HWICMR software...
x HWICMR, 0 bytes, 0 tape blocks
x HWICMR/agent, 0 bytes, 0 tape blocks
......
The HWICMR agent has been installed successfully.
Installing the HWICMR configuration file...
The HWICMR configuration file has been installed successfully.
......
For more installation messages refer to the installation logfile:
/var/sadm/install_data/Solaris_10_Extra_log
The configuration of system has been modified, so the system must be reboot.
Please press ENTER to reboot the system.
NOTE
To install from the hard disk, run the following command to access the corresponding directory:
# cd /export/disk1
Step 9 Run the following command to install the remaining operating system patches:
# ./install_patches.sh
----End
Prerequisite
The following CD-ROMs or the installation packages must be prepared:
l T2000 for UNIX installation CD-ROM #2 (T2000 application CD-ROM) or installation
software package: t2000v200r005c01b0xxen_unix_cd2.tar
l T2000 for UNIX installation CD-ROM #3 (Tool software CD-ROM) or installation
software package: t2000v200r005c01b0xx_unix_cd3.tar
To install the software from the hard disk, FTP the installation packages to the /export directory
of the server in the bin mode. Run the following commands to uncompress the installation
packages:
# cd /export
# tar xvf t2000v200r005c01b0xxen_unix_cd2.tar
# tar xvf t2000v200r005c01b0xx_unix_cd3.tar
Context
CAUTION
During the installation, the system may take some time to respond after you press Enter. Do not
perform any operation until the system displays the corresponding operation result.
NOTE
Your session answers are stored as defaults for the next time you run this menu option.
Procedure
Step 1 Open a terminal window. Select Options > Font Size > Default, and then select Options >
Window Size > 132x24 from the menu to adjust the terminal window as required.
Select the installation type. The installation wizard will guide you through
the rest of the installation process according to the installation type you
selected.
Select[1]:
Step 3 Enter 1.
Host name is the only ID of the host. It is the name used to indicate the
host
in the network. Host name for each host is unique in the network.
Press Enter to use the current host name, or enter a new host name.
The new host name will take into effect after the host reboots.
The host name can contain numerals, letters, dots, minus signs, and
underlines. It must begin with a letter or an underline, and end with a letter or
numeral.
Enter[T2000]:
Step 4 Enter the host name that is previously planned, for example, T2000.
1. bge0
2. bge1
3. bge2
4. bge3
Select[1]:
NOTE
l The system automatically detects the names of network cards. These names given above may vary with
the hardware. For example, ce, eri, bge, and so on.
l If you press Enter directly, the system uses the network card represented by the number within the
bracket.
l The prompt information given above will not be displayed if the workstation has only one network
card.
Step 5 Enter 1.
The terminal displays:
======= IP Address of the Master NIC =======
Enter[129.9.1.1]:
Step 6 Enter the IP address that is previously planned, for example, 129.9.1.1.
The terminal displays:
======= Subnet Mask of the Master NIC =======
Enter[255.255.255.0]:
Step 7 Enter the mask address that is previously planned, for example, 255.255.255.0.
The terminal displays:
======= Information Confirmation =======
Confirm[Y]:
Step 8 Enter Y.
The terminal displays:
======= Install SYBASE Software =======
Enter[Y]:
Step 9 Enter Y.
The terminal displays:
======= SYBASE Installation Directory =======
Enter[/opt/sybase]:
Confirm[Y]:
Step 11 Enter Y.
The terminal displays:
======= Install OptiX iManager T2000 =======
Enter "Y" to install the T2000 software. Enter "N" to skip this step.
Enter[Y]:
Step 12 Enter Y.
The terminal displays:
======= OptiX iManager T2000 Installation Directory =======
Enter[/T2000]:
Select (You can select multiple items and separate them with spaces.)[1 2]:
Step 14 Enter 1 2.
NOTE
Enter 1 2 to install all components including both the client and server software. Therefore, enter 1 2 for
single-system structure installation, 1 for independent client and 2 for independent server.
Select[1]:
NOTE
The timeslot modes include the numbering mode and the interleaved mode which determined by the way
in which VC12 timeslots are numbered in a VC4. For the two numbering modes, refer to F Timeslot
Numbering Policy.
Step 15 Enter 1.
The terminal displays:
======= Information Confirmation =======
Confirm[Y]:
Step 16 Enter Y.
The terminal displays:
======= Northbound Interface =======
Select(You can select multiple items and separate them with spaces.)[]:
NOTE
l You can also configure the CORBA interface with the T2000 config tool. For details, refer to the OptiX
iManager T2000 Northbound CORBA Interface User Guide.
Confirm[Y]:
Step 18 Enter Y.
Select[Y]:
Step 19 Enter N.
Confirm[Y]:
Step 20 Enter Y.
Acquire the software package from the CD-ROM or from the hard disk
Name of Software Package: sybase12.5.3.3.tar.bz2
Option 1: From the CD-ROM
Option 2: From the hard disk. The path of the software package is
required.
1. CD-ROM
2. Hard disk
Select[1]:
NOTE
l To install the software from the hard disk, make sure the sybase12.5.3.3.tar.bz2 file (extracted from
the t2000v200r005c01b0xx_unix_cd3.tar package) is prepared.
l The installation program automatically searches for the file in the /export/disk3/tools directory. If the
file is already there, the program automatically starts the installation. Otherwise, enter the path of the
file.
Step 21 Enter 1.
The terminal displays:
======= Insert CD-ROM =======
Step 22 Insert the T2000 installation CD-ROM #3 (Tool software CD-ROM). Press Enter to continue.
The installation of the Sybase database software starts. After the installation, the terminal
displays:
NOTE
l To install the T2000 from the hard disk, make sure the t2000v200r005c01.tar.bz2 file (uncompressed
from the t2000v200r005c01b0xxen_unix_cd2.tar package) is available.
l The installation program automatically searches for the t2000v200r005c01.tar.bz2 file in the /export/
disk2 directory. If the file is already there, the program automatically starts the installation. Otherwise,
enter the path of the file.
Install SYBASE Software........................................Done
Acquire the software package from the CD-ROM or from the hard disk?
Name of Software Package: t2000v200r005c01.tar.bz2
Option 1: From the CD-ROM
Option 2: From the hard disk. The path of the software package is
required.
1. CD-ROM
2. Hard disk
Select[1]:
Step 23 Enter 1.
The terminal displays:
======= Insert CD-ROM =======
Step 24 Insert the T2000 installation CD-ROM #2 (OptiX iManager T2000 application CD-ROM). Press
Enter to continue.
The installation of the T2000 software starts. After the installation, the terminal displays:
Install OptiX iManager T2000 software..........................Done
Build database server and backup server........................Done
Configure OptiX iManager T2000 software........................Done
......
Initialize OptiX iManager T2000 database.......................Done
......
Step 25 If you install the T2000 from CD-ROM, run the following commands to eject the CD-ROM:
# cd /
# eject
Step 27 Log in to the system as user t2000. If you log in to the system as t2000 for the first time, the
system prompts you to set the password. After that, the login interface is displayed again.
Step 28 Log in to the system as user t2000. The system prompts you to select the default desktop.
----End
Procedure
Step 1 Apply for a T2000 license.
NOTE
l Transfer the license file in the ASCII mode as user t2000. Otherwise, the license fails.
Step 2 Copy the valid T2000 license file to the T2000 directory.
NOTE
The default directory is /T2000/server.
----End
Procedure
Step 1 Right-click a blank area of the desktop and choose Tools > Create Action from the shortcut
menu. The Create Action dialog box is displayed.
CAUTION
Be aware that the letters are case sensitive. Especially, the program path which the shortcut icon
points to should be correct.
Step 3 Choose File > Save to save the new action (saved in the start directory). Then close the Create
Action dialog box.
Step 4 Right-click a blank area of the desktop and choose the Folders > File Manager - Home from
the shortcut menu. The File Manager dialog box is displayed.
Step 5 Right-click the T2000Client icon and choose Put in Workspace from the shortcut menu. On
the desktop, the T2000 shortcut icon is displayed, indicating that the process was successful.
Step 7 Repeat this procedure to create the T2000 server icon. For information that differs from the
T2000 client, refer to Table 4-1.
----End
Prerequisite
The T2000 applications must be normally shut down.
Procedure
Step 1 Configure the northbound interfaces.
1. Configure the CORBA interface. Refer to the OptiX iManager T2000 Northbound CORBA
Interface Developer Guide.
2. Configure the SNMP interface. Refer to the OptiX iManager T2000 Northbound SNMP
Interface Developer Guide.
3. Configure the MML interface.
a. By using the vi command, open the ems.cfg file in the server directory in the
installation path of the T2000. By default, the installation path is \T2000\server.
b. Search for the "te_mml" string, to find "#LoadModule_** = te_mml". Remove "#"
and save the file.
c. Restart the T2000 server to apply the settings.
Step 2 Open a terminal window. Select Options > Font Size > Default, and then select Options >
Window Size > 132x24 from the menu to adjust the terminal window as required.
Step 3 Run the following commands in the terminal window:
# cd /opt/HWICMR/bin
# ./runtaskflow.sh config_nbi_ha.tf
Select(You can select multiple items and separate them with spaces.)[]:
Step 4 Select the interfaces to be enabled. You can select multiple items and separate them with spaces.
NOTE
Select[Y]:
Step 6 Enter N.
The terminal displays:
======= Information Confirmation =======
Confirm[Y]:
Step 7 Enter Y.
The terminal displays:
Configure OptiX iManager T2000 software........................Done
Configure the northbound interface..................................Done
/var/ICMR/ICMR_LOG_20070318161630
----End
Prerequisite
The workstation has two hard disks with the same capacity and is not used for high availability
(HA) system installation.
Procedure
Disk mirroring is recommended. To know how to create a disk mirror, refer to B.1 Creating
Disk Mirror.
----End
normally and the data in the NE is correct, upload the data from the NE to the T2000. After
uploading, you need to perform a consistency check.
4.8.9 Checking Consistency of Configuration Data Between an NE and the T2000
A consistency check is done to compare the configuration data in the NEs with the data in the
T2000. After the check, a report of the result is created. If the result shows the configuration
data is inconsistent, you need to upload the configuration data from the NE to the T2000 or
download the data from the T2000 to the NE for data synchronization.
4.8.10 Viewing Current NM Alarms
By viewing the current NM alarms, you can query the status of the T2000 and whether the
communication between the T2000 and NEs is normal. When you view all the current alarms
on the T2000, you can perform other operations for these alarms at the same time. For example,
synchronize, refresh, check, acknowledge and filter alarms.
Procedure
Step 1 After the T2000 is installed, the T2000 directory must exist.
The following files or directories should exist by default: /T2000
Step 2 After the T2000 is installed, the Sybase directory must exist.
The following files or directories should exist by default: /opt/sybase
----End
Procedure
Step 1 After you install the T2000, open a terminal window and log in as user root.
----End
Procedure
Step 1 Open a terminal window and log in as user root.
NOTE
If you log in to the system as user sybase for the first time, the system prompts you to set the password.
To ensure the system security, periodically change the password of user sybase using the passwd
sybase command. The password must contain a minimum of eight characters.
----End
Procedure
Step 1 Double-click the T2000Server icon on the desktop.
The System Monitor window with a login dialog box is displayed in several seconds.
Step 2 Enter the user name, password and server. After you successfully log in to the T2000 server,
wait until all required T2000 processes are in the Running state.
NOTE
l By default, the initial user name of the Sysmonitor client is admin, the password is T2000 and the
server is Local.
l To ensure the T2000 security, change the password in a timely manner. Be sure to remember it, for it
will be used again afterwards.
l By default, the initial user name of the T2000 client is admin, the password is T2000 and the server
is Local.
l To allow different users to manage the T2000, create new NM users and assign authorities to them in
a timely manner.
l You can click to set the IP address and port number of the T2000 server.
----End
Result
If all the previous checks are passed, the installation of the T2000 on UNIX proves successful.
Prerequisite
The T2000 server must be installed.
Procedure
Run the more command to view the ems.cfg file in the $IMAP directory. If you have enabled
the MML interface when you install the T2000, the screen displays as follows:
#@ upper class NMS interface module (optional)
LoadModule_** = te_mml
NOTE
l The $IMAP variable represents the installation directory of the T2000 server. For example, if the T2000
server is installed in the directory /T2000/server on UNIX, the $IMAP points to the directory /T2000/
server.
l "**" refers to the serial number.
l If the ems.cfg file contains "#LoadModule_** =te_mml", it indicates that the function that the MML
interface corresponds to is disabled, because "#" indicates that the function defined in this row is
disabled.
----End
Prerequisite
The T2000 server must be installed.
Procedure
l Run the following command to view the licenseXXXXXXX.txt file (each X represents an
integer between 0 and 9) in the $IMAP path.
# more licenseXXXXXXX.txt
NOTE
The $IMAP variable represents the installation directory of the T2000 server. For example, if the
T2000 server is installed in the directory /T2000/server on UNIX, the $IMAP points to the
directory /T2000/server.
l Check the T2000 CORBA interface software. If the files listed in the following table exist,
it indicates that the T2000 CORBA interface software is correctly installed.
l Run the following command to view the ems.cfg file in the $IMAP path.
# more ems.cfg
If you have enabled the CORBA interface when you install the T2000, the screen displays
as follows:
LoadModule_** = te_corba_core
LoadModule_** = te_corba_snc
LoadModule_** = te_corba_gct
LoadModule_** = te_corba_mstp
LoadModule_** = te_corba_ctrlplane
LoadModule_** = te_corba_flowdomain
NOTE
----End
Prerequisite
The T2000 server must be installed.
Procedure
l Run the following commands to view the licenseXXXXXXX.txt file (X represents integers
between 0 and 9) in the $IMAP path.
# more licenseXXXXXXX.txt
Check whether the T2000 license file contains the SNMP item and whether SupportSnmpIF
is set to 1. If the license does not support the SNMP interface, you need to apply a license
for the SNMP interface.
NOTE
The $IMAP variable points to the T2000 server installation directory. For example, if the T2000
server is installed in the /T2000/server directory on UNIX, $IMAP points to /T2000/server.
l Run the following command to view the ems.cfg file in the $IMAP directory.
# more ems.cfg
If you have enabled the SNMP interface when you install the T2000, the screen displays
as follows:
LoadModule_** = te_snmp
NOTE
----End
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs from the Object Tree and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Upload. Alternatively, right-click and select Upload from the shortcut menu.
Step 5 Click OK in the confirmation dialog box.
Step 6 Click Close in the Operation Result dialog box.
----End
data is inconsistent, you need to upload the configuration data from the NE to the T2000 or
download the data from the T2000 to the NE for data synchronization.
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Context
l Configuration data consistency check between the T2000 and NEs does not change the
configuration data in the NEs and in the T2000.
l To ensure that the T2000 properly manages the NEs, it is recommended that you run this
function on a monthly basis to keep the consistency of configuration data in NEs and the
T2000 server.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs in the left pane and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Consistency Check. Alternatively, right-click the NE and select Consistency Check from
the shortcut menu.
l If the result indicates an inconsistency in the configuration data between the NE and the T2000, you
need to upload or download the data to achieve consistency.
l Click Save As to save inconsistent information to a file.
----End
Prerequisite
To view the alarms, you must be an NM user with the "NE and Network Monitor" authority or
higher. To acknowledge, check, synchronize or delete alarms, you must be an NM user with the
"NM Monitor" authority or higher.
Procedure
Step 1 Right-click the local NM icon on the Main Topology and choose Browse Current Alarms. The
current NM alarms of all severity levels are displayed.
You can also choose Fault > Browse Current Alarms from the Main Menu and select the local
NM to view the current NM alarm.
Step 2 If you want to display the latest alarms, check the Display the Latest Alarms check box.
NOTE
The function of the checked check box is equivalent to the refresh function. Thus, when the check box is
checked, the Refresh button is grayed out.
Step 3 To query alarms by certain criteria, click Filter, and the Filter dialog box is displayed.
NOTE
If you check the Display the Lasted Alarms check box, in the Filter dialog box that is displayed, the
Cleared Time filter criteria is not available.
Step 4 Set the filter criteria, such as Alarm Name, Remark, Rising Time, Alarm Status, Alarm
Severity, Alarm Type and so on. Then, click Filter to filter the alarms.
The alarm information is displayed according to the criteria you set.
Step 5 Optional: Select one or more alarms, and click Check to check the selected alarms.
NOTE
An alarm check helps you to confirm the status of the uncleared alarms. It also clears the alarms that are
actually cleared but still are uncleared in the NM alarm library.
Step 6 Select an alarm. Its details and causes are displayed in the table below.
Step 7 Select one or more alarms and click Acknowledge. The Operation Result dialog box is
displayed.
Step 8 Click Close. The corresponding parameter values are displayed in the Ack Time and Ack
User fields.
NOTE
Acknowledged and cleared alarms automatically change to history alarms.
Step 9 Select one or more alarms and click Delete. The Delete Alarms dialog box is displayed. Click
Yes.
The progress bar about the alarm deletion is displayed.
Step 10 Click Yes in the Operation Result dialog box.
Step 11 Optional: Click Print or Save As to output the alarm data.
----End
Prerequisite
l The Windows XP Professional (SP2) or Windows Server 2003 Standard Edition (SP1) have
been installed in the computer.
l A user t2000 that has the administrator authority must be created.
Context
NOTE
This procedure illustrates the T2000 installation on Windows XP Professional (Service Pack 2). The
installation procedure on other Windows platforms is the same. Therefore, you can refer to this procedure
when installing T2000 on other Windows Platforms.
Procedure
Step 1 Log in to Windows as user t2000.
Step 2 Insert the T2000 for Windows installation CD-ROM #1 or uncompress the installation software
package: t2000v200r005c01b0xx_en_pc_cd1.zip. Run the setup.exe file.
Step 4 Select I accept the terms of the license agreement, and click Next.
NOTE
The timeslot modes include the numbering mode and the interleaved mode which determined by the way
in which VC12 timeslots are numbered in a VC4. For the two numbering modes, refer to F Timeslot
Numbering Policy.
Step 10 You can obtain the directory for the installation file from a CD-ROM or a hard disk.
l From a CD-ROM: Insert CD-ROM #2 and click Browse... to select the directory for the
CD-ROM.
l From a hard disk: Select the path for the installation file (uncompress from the
t2000v200r005c01b0xx_en_pc_cd2.zip package. Make sure that the uncompressed file
path is short and contains no space or punctuation.)
NOTE
l For Windows Server 2003 Standard Edition, you should insert CD-ROM #3. To install the software
from the hard disk, select the directory for the installation files (uncompress from the
t2000v200r005c01b0xx_en_pc_cd3.zip package).
l When you install the T2000 on Windows Server 2003 Standard Edition, a prompt may appear telling
you that the operating system does not support the current SQL Server version and the patch version.
As the installation setup will automatically install SQL Server 2000 SP4, click Continue.
----End
Procedure
Step 1 Log in to Windows as user t2000. The DOS window and the message are displayed.
NOTE
The Initializing database message is covered by the DOS Window. Drag the DOS window away and you
can see the message.
----End
Prerequisite
An authorized T2000 license must be obtained.
Procedure
Copy the valid license file to the T2000 server installation folder.
For example, the default directory is C:\T2000\server.
NOTE
----End
Procedure
Step 1 Open the ems.cfg file in the T2000 server directory. The default directory is C:\T2000\server.
Step 2 Search for the "te_mml" string, to find "#LoadModule_** = te_mml". Remove "#" and save the
file.
Step 3 Restart the T2000 server to apply the settings.
----End
Prerequisite
Before you enable the CORBA interface, check whether the following items are realized:
l The T2000 license includes the CORBA items, and the CORBA items SupportCorbaIFBase
is set to 1 and SupportCorbaIFAdv is set to 1.
l The T2000 is correctly installed. That is, the T2000 is able to be normally started without
enabling the CORBA interface.
Context
NOTE
Use the T2000 config tool to configure the CORBA interface and enable CORBA services. For details, refer to
the OptiX iManager T2000 Northbound CORBA Interface User Guide.
Procedure
Step 1 Open the ems.cfg file in the T2000 server directory. By default, the installation directory is C:
\T2000\server.
Search for "te_corba" to find the following information
#LoadModule_** = te_corba_core
#LoadModule_** = te_corba_snc
#LoadModule_** = te_corba_gct
#LoadModule_** = te_corba_mstp
#LoadModule_** = te_corba_ctrlplane
#LoadModule_** = te_corba_flowdomain
NOTE
Step 2 Log in to the T2000 Sysmonitor client, and enable the naming service and notification
service processes.
----End
Prerequisite
The T2000 license supports the SNMP interface. That is, the T2000 license file contains the
SNMP item and SupportSnmpIF is set to 1.
Procedure
Step 1 Modify the ems.cfg file.
NOTE
The ems.cfg file is placed at %IMAP%\ems.cfg.
In the ems.cfg file, enable the SNMP module. That is, remove "#" from "#LoadModule_** =
te_snmp".
Step 2 Start the T2000.
NOTE
For the Sysmonitor to monitor the SNMP process, the %IMAP%\sysmoni\monisnmpagent.cfg file must
exist.
Use Sysmonitor to start the T2000. After the T2000 process is started, start the SNMP process
in the Sysmonitor.
----End
Prerequisite
The T2000 and the MS SQL server must be successfully installed on Windows.
5.7.1 Checking Directories and Files
After the T2000 is installed, you can check whether directories and files are correct.
5.7.2 Checking the Running Status of Databases
After the T2000 is installed, you can check the running status of databases.
Procedure
Step 1 Check whether the T2000 folder exists. The default directory is C:\T2000.
Step 2 Check the shortcut icons.
1. There must be T2000 Server and T2000 Client shortcut icons on the Windows desktop.
2. Choose Start > Programs , and there should be the iManager T2000 shortcut directory
with T2000Server and T2000Client shortcut items.
Step 3 Check the environment variables.
1. Right-click My Computer on the desktop and choose Properties from the shortcut menu.
Click the Advanced tab.
2. Click Environment Variables. The IMAP variable should exist in the System
Variables area of the dialog box displayed.
NOTE
l If the T2000 is installed in C:\T2000, the value of the IMAP variable is C:\T2000\server.
l If the T2000 is installed in other directories, the variable changes accordingly.
----End
Procedure
Choose Start > Programs > Microsoft SQL Server > Service Manager . The SQL Server
should be correctly started.
----End
Procedure
Step 1 Double-click the T2000Server icon on the desktop.
The System Monitor Client window with a login dialog box is displayed in several seconds.
Step 2 Enter the user name, password and server. After you successfully log in to the T2000 server,
wait until the Ems Server, Schedulesrv Server, Security Server, Topo Server, Syslog
Agent, Toolkit Server, WebLCT Server and Database Server Process are all in the
Running state.
NOTE
l By default, the initial user name of the Sysmonitor client is admin, the password is T2000 and the
server is Local.
l To ensure the T2000 security, change the password in a timely manner. Be sure to remember it, for it
will be used again afterwards.
Step 4 Enter the user name, password and the IP address of the server.
NOTE
By default, the initial user name of the T2000 client is admin, the password is T2000 and the server is
Local. To allow different users to manage the T2000, create new NM users and assign authorities to them
in a timely manner. You can click to set the IP address and port number of the T2000 server for login.
----End
Prerequisite
The T2000 server must be installed.
Procedure
Step 1 Open the ems.cfg file in the T2000 server directory. By default, the installation directory is C:
\T2000\server.
Step 2 Search for the "te_mml" string. If you find "LoadModule_**= te_mml", it indicates that the
MML interface is enabled.
NOTE
----End
Prerequisite
The T2000 server must be installed.
Procedure
Step 1 Check the T2000 license.
Check the licenseXXXXXXX.txt (each X represents an integer between 0 and 9) file in %IMAP
%. If SupportCorbaIFBase is set to 1 and SupportCorbaIFAdv is set to 1, it indicates that the
T2000 license supports the CORBA interface.
NOTE
If the T2000 server is installed in c:\T2000\server, %IMAP% points to c:\T2000\server.
%IMAP%\bin te_corba_core.dll The dynamic library files for the CORBA interface
te_corba_alm.dll software
te_corba_ems.dll
te_corba_env.dll
te_corba_eqt.dll
te_corba_gct.dll
te_corba_maintena
nce.dll
te_corba_me.dll
te_corba_pfm.dll
te_corba_pro.dll
te_corba_pub.dll
te_corba_snc.dll
te_corba_mstp.dll
te_corba_topo.dll
te_corba_flowdom
ain.dll
Step 3 Open the ems.cfg file in the T2000 server directory, which is default to C:\T2000\server.
By finding "te_corba", check whether the ems.cfg file contains the following information.
LoadModule_** = te_corba_core
LoadModule_** = te_corba_snc
LoadModule_** = te_corba_gct
LoadModule_** = te_corba_mstp
LoadModule_** = te_corba_ctrlplane
LoadModule_** = te_corba_flowdomain
If the ems.cfg file contains such information, it indicates that the CORBA interface is enabled.
NOTE
----End
Prerequisite
The T2000 server must be installed.
Procedure
Step 1 Check whether the T2000 license supports the SNMP interface feature.
Check the licenseXXXXXXX.txt (each X represents an integer between 0 and 9) file in %IMAP
%.
l If SupportSnmpIF is set to 1, it indicates that the T2000 license supports the SNMP interface.
l If the license does not support the SNMP interface, you need to apply a license for the SNMP
interface.
NOTE
If the T2000 server is installed in c:\T2000\server, %IMAP% points to c:\T2000\server.
Step 2 Navigate to the ems.cfg file in the T2000 server directory. By default, the installation directory
is C:\T2000\server.
Search for "te_snmp", if you find "LoadModule_** =te_snmp", it indicates that the SNMP
interface is enabled.
NOTE
Step 3 Check whether the monisnmpagent.cfg file exists in the %IMAP%\sysmoni directory.
----End
Result
If you have completed the previous steps, the SNMP interface is successfully installed.
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs from the Object Tree and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Upload. Alternatively, right-click and select Upload from the shortcut menu.
----End
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Context
l Configuration data consistency check between the T2000 and NEs does not change the
configuration data in the NEs and in the T2000.
l To ensure that the T2000 properly manages the NEs, it is recommended that you run this
function on a monthly basis to keep the consistency of configuration data in NEs and the
T2000 server.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs in the left pane and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Consistency Check. Alternatively, right-click the NE and select Consistency Check from
the shortcut menu.
l If the result indicates an inconsistency in the configuration data between the NE and the T2000, you
need to upload or download the data to achieve consistency.
l Click Save As to save inconsistent information to a file.
----End
Prerequisite
To view the alarms, you must be an NM user with the "NE and Network Monitor" authority or
higher. To acknowledge, check, synchronize or delete alarms, you must be an NM user with the
"NM Monitor" authority or higher.
Procedure
Step 1 Right-click the local NM icon on the Main Topology and choose Browse Current Alarms. The
current NM alarms of all severity levels are displayed.
You can also choose Fault > Browse Current Alarms from the Main Menu and select the local
NM to view the current NM alarm.
Step 2 If you want to display the latest alarms, check the Display the Latest Alarms check box.
NOTE
The function of the checked check box is equivalent to the refresh function. Thus, when the check box is
checked, the Refresh button is grayed out.
Step 3 To query alarms by certain criteria, click Filter, and the Filter dialog box is displayed.
NOTE
If you check the Display the Lasted Alarms check box, in the Filter dialog box that is displayed, the
Cleared Time filter criteria is not available.
Step 4 Set the filter criteria, such as Alarm Name, Remark, Rising Time, Alarm Status, Alarm
Severity, Alarm Type and so on. Then, click Filter to filter the alarms.
The alarm information is displayed according to the criteria you set.
Step 5 Optional: Select one or more alarms, and click Check to check the selected alarms.
NOTE
An alarm check helps you to confirm the status of the uncleared alarms. It also clears the alarms that are
actually cleared but still are uncleared in the NM alarm library.
Step 6 Select an alarm. Its details and causes are displayed in the table below.
Step 7 Select one or more alarms and click Acknowledge. The Operation Result dialog box is
displayed.
Step 8 Click Close. The corresponding parameter values are displayed in the Ack Time and Ack
User fields.
NOTE
Acknowledged and cleared alarms automatically change to history alarms.
Step 9 Select one or more alarms and click Delete. The Delete Alarms dialog box is displayed. Click
Yes.
The progress bar about the alarm deletion is displayed.
Step 10 Click Yes in the Operation Result dialog box.
Step 11 Optional: Click Print or Save As to output the alarm data.
----End
If you need to install an independent T2000 client program on Windows, adopt the scheme of
installing an independent T2000 client.
Prerequisite
l The Windows XP Professional (SP2) or Windows Server 2003 Standard Edition (SP1) have
been installed in the computer.
l Other applications and anti-virus software are closed.
l Make sure you have the T2000 for Windows installation CD-ROM #1 or software package
in hand.
NOTE
l To install the T2000 client from the hard disk, make sure you have the following installation
software package: t2000v200r005c01b0xx_en_pc_cd1.zip.
l The directory of the installation software package should be simplified. Make sure that no space,
punctuation or non-English character exists in the path.
l This manual illustrates how to install the T2000 client on Windows XP Professional (SP2). The
installation procedure on other Windows platforms is the same. Therefore, you can refer to this
procedure when installing T2000 on other Windows platforms.
Procedure
Step 1 Log in to Windows XP as an operating system user with administrator authority.
CAUTION
To properly run the T2000 client after the installation is complete, you must log in to the
Windows operating system as the same user that you used during the installation.
Step 2 Insert the T2000 for Windows installation CD-ROM #1 or uncompress the installation software
package: t2000v200r005c01b0xx_en_pc_cd1.zip. Run the setup.exe file. The installation
interface is displayed.
Step 3 Wait until the Welcome to the InstallShield Wizard for iManager T2000 dialog box is
displayed.
Step 5 Select I accept the terms of the license agreement, and click Next. The Choose Destination
Location dialog box is displayed.
NOTE
Step 7 Select Client and click Next. The Ready to Install the Program dialog box is displayed.
----End
Prerequisite
The T2000 server and client must be installed.
6.2.1 Uploading NE Configuration Data
The NE configuration data in the T2000 may differ from that in the NE. During maintenance,
you need to keep the data in the T2000 consistent with the data in the NE. If the network runs
normally and the data in the NE is correct, upload the data from the NE to the T2000. After
uploading, you need to perform a consistency check.
6.2.2 Checking Consistency of Configuration Data Between an NE and the T2000
A consistency check is done to compare the configuration data in the NEs with the data in the
T2000. After the check, a report of the result is created. If the result shows the configuration
data is inconsistent, you need to upload the configuration data from the NE to the T2000 or
download the data from the T2000 to the NE for data synchronization.
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs from the Object Tree and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Upload. Alternatively, right-click and select Upload from the shortcut menu.
----End
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Context
l Configuration data consistency check between the T2000 and NEs does not change the
configuration data in the NEs and in the T2000.
l To ensure that the T2000 properly manages the NEs, it is recommended that you run this
function on a monthly basis to keep the consistency of configuration data in NEs and the
T2000 server.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs in the left pane and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Consistency Check. Alternatively, right-click the NE and select Consistency Check from
the shortcut menu.
l If the result indicates an inconsistency in the configuration data between the NE and the T2000, you
need to upload or download the data to achieve consistency.
l Click Save As to save inconsistent information to a file.
----End
Prerequisite
To view the alarms, you must be an NM user with the "NE and Network Monitor" authority or
higher. To acknowledge, check, synchronize or delete alarms, you must be an NM user with the
"NM Monitor" authority or higher.
Procedure
Step 1 Right-click the local NM icon on the Main Topology and choose Browse Current Alarms. The
current NM alarms of all severity levels are displayed.
You can also choose Fault > Browse Current Alarms from the Main Menu and select the local
NM to view the current NM alarm.
Step 2 If you want to display the latest alarms, check the Display the Latest Alarms check box.
NOTE
The function of the checked check box is equivalent to the refresh function. Thus, when the check box is
checked, the Refresh button is grayed out.
Step 3 To query alarms by certain criteria, click Filter, and the Filter dialog box is displayed.
NOTE
If you check the Display the Lasted Alarms check box, in the Filter dialog box that is displayed, the
Cleared Time filter criteria is not available.
Step 4 Set the filter criteria, such as Alarm Name, Remark, Rising Time, Alarm Status, Alarm
Severity, Alarm Type and so on. Then, click Filter to filter the alarms.
The alarm information is displayed according to the criteria you set.
Step 5 Optional: Select one or more alarms, and click Check to check the selected alarms.
NOTE
An alarm check helps you to confirm the status of the uncleared alarms. It also clears the alarms that are
actually cleared but still are uncleared in the NM alarm library.
Step 6 Select an alarm. Its details and causes are displayed in the table below.
Step 7 Select one or more alarms and click Acknowledge. The Operation Result dialog box is
displayed.
Step 8 Click Close. The corresponding parameter values are displayed in the Ack Time and Ack
User fields.
NOTE
Acknowledged and cleared alarms automatically change to history alarms.
Step 9 Select one or more alarms and click Delete. The Delete Alarms dialog box is displayed. Click
Yes.
The progress bar about the alarm deletion is displayed.
Step 10 Click Yes in the Operation Result dialog box.
Step 11 Optional: Click Print or Save As to output the alarm data.
----End
If you need to install an independent T2000 client on UNIX, adopt the scheme of installing an
independent T2000 client.
Context
NOTE
The following procedure describes how to use CD-ROMs to install Solaris 10. To install the Solaris 10 by
using the DVD (only one piece), you can refer to this procedure.
Procedure
Step 1 Start the workstation.
Step 3 Insert the CD/DVD for Solaris 10 Software 1 (01/06 SPARC Platform Edition). Run the
following command at the ok prompt to restart the system:
boot cdrom
In about five minutes, the system prompts you to select the language for installation.
Step 4 Enter 0 to select English as the language for installation and then press Enter.
The Welcome dialog box is displayed.
l This dialog box is not displayed on the computer that has only one network card.
l Usually, it is recommended that you select the first option.
l To identify the network port corresponding to the name of each network card, refer to 9.11 Identifying
Network Card Name after the operating system is successfully installed.
Step 11 Enter the confirmed subnet mask 255.255.255.0 and click Next.
The IPv6 dialog box is displayed.
Step 18 Set the region and time zone correctly, and click Next.
The Date and Time dialog box is displayed.
Step 20 Enter rootkit, the password of user root twice and click Next.
NOTE
rootkit is the default password for the super user root. After installing the OS, change the default password
immediately through GUI or command line. The password should not be less than eight characters.
The Confirm Information dialog box is displayed.
Step 23 Select Yes in the Reboot automatically after software installation? field and select Yes in the
Eject a CD/DVD automatically after software installation? field, and then click Next.
The Specify Media dialog box is displayed.
If the Select Upgrade or Initial install dialog box is displayed, the system is upgradeable. If a backup of
the previous Solaris version is not needed, select Initial Install and click Next.
Step 32 Set the Software Group Entire Group Plus OEM, Default Packages and click Next.
The Disk Selection dialog box is displayed.
Step 36 Enter the name and the size of each partition. After that, click other areas in the table. The system
refreshes the unused disk space.
NOTE
l There are no special requirements for disk partition of the client workstation.
l The recommended partition shown in the following table is for reference only.
If the Pausing dialog box is displayed during the installation, click Continue.
After the system restarts, the Do you need to override the system's default NFS version 4
domain name (yes/no)? dialog box is displayed.
Step 40 Enter no, and press Enter.
The Specify Media dialog box is displayed.
Step 41 Select CD/DVD to specify the media from which to install Solaris 10 Software 2 for SPARC
Platform, and click Next.
The system automatically ejects the Solaris 10 Software 1 (01/06 SPARC Platform Edition)
disk.
Step 42 Insert the CD/DVD for Solaris 10 Software 2 (01/06 SPARC Platform Edition), and then click
OK.
The Ready to Install dialog box is displayed.
Step 43 Click Install Now.
The installation of Solaris 10 Software 2 (01/06 SPARC Platform Edition) takes approximately
20 minutes. After that, the Specify Media dialog box is displayed.
Step 44 Select CD/DVD to specify the media from which to install Solaris 10 Software 3 for SPARC
Platform, and click Next.
The system automatically ejects the Solaris 10 Software 2 (01/06 SPARC Platform Edition)
disk.
Step 45 Insert the CD/DVD for Solaris 10 Software3 (01/06 SPARC Platform Edition), and then click
OK. The Ready to Install dialog box is displayed.
The Specify Media dialog box is displayed.
Step 46 Select CD/DVD to specify the media from which to install Solaris 10 Software 4 for SPARC
Platform, and click Next.
The system automatically ejects the Solaris 10 Software 3 (01/06 SPARC Platform Edition)
disk.
Step 47 Insert the CD/DVD for Solaris 10 Software 4 (01/06 SPARC Platform Edition), and then click
OK.
The Ready to Install dialog box is displayed.
Step 48 Click Install Now.
The system is restarted.
Step 49 Log in to the Solaris system as user root.
The Select Desktop Environment dialog box is displayed.
Step 50 Select Common Desktop Environment (CDE), and click OK.
Now the installation of Solaris 10 is complete.
----End
Procedure
Step 1 Log in to the system as user root. Insert the T2000 for UNIX installation CD-ROM #1 (System
patches CD-ROM) or prepare the installation package:
t2000v200r005c01b0xx_unix_cd1.tar.
TIP
If the installation software package needs to be transferred by FTP, run the following commands first to
enable the FTP function for user root.
# sed "/^root/s//#root/g" /etc/ftpd/ftpusers > /tmp/ftpusers
# cp /tmp/ftpusers /etc/ftpd/ftpusers
Then transfer the software package to the /export directory in the bin mode.
Step 2 Run the following command in the terminal window and enter the installation path:
# cd /cdrom/cdrom0
NOTE
To install the software from the hard disk, run the following commands to uncompress the installation
package and navigate to the installation directory:
# cd /export
# tar xvf t2000v200r005c01b0xx_unix_cd1.tar
# cd disk1
NOTE
The value of the key fingerprint is displayed according to the actual situation.
Your identification has been saved in //.ssh/id_rsa.
Your public key has been saved in //.ssh/id_rsa.pub.
The key fingerprint is:
05:28:0f:03:c5:19:35:27:33:4e:53:f0:ab:47:3e:52 root@T2000
......
Installing the HWICMR software...
x HWICMR, 0 bytes, 0 tape blocks
x HWICMR/conf, 0 bytes, 0 tape blocks
x HWICMR/conf/locales, 0 bytes, 0 tape blocks
x HWICMR/conf/locales/C, 0 bytes, 0 tape blocks
......
Step 8 In the terminal window, run the following command to access the corresponding directory:
# cd /cdrom/cdrom0
NOTE
To install from the hard disk, run the following command to access the corresponding directory:
# cd /export/disk1
Step 9 Run the following command to install the remaining operating system patches:
# ./install_patches.sh
----End
Prerequisite
The following CD-ROM or the installation package must be prepared:
l T2000 for UNIX installation CD-ROM #2 (T2000 application CD-ROM) or installation
software package: t2000v200r005c01b0xxen_unix_cd2.tar
To install the software from the hard disk, FTP the installation package to the /export directory
of the server in the bin mode. Run the following commands to uncompress the installation
package:
# cd /export
# tar xvf t2000v200r005c01b0xxen_unix_cd2.tar
Context
CAUTION
During the installation, the system may take some time to respond after you press Enter. Do not
perform any operation until the system displays the corresponding operation result.
NOTE
Your session answers are stored as defaults for the next time you run this menu option.
Procedure
Step 1 Open a terminal window. Select Options > Font Size > Default, and then select Options >
Window Size > 132x24 from the menu to adjust the terminal window as required.
Step 2 Run the following commands in the terminal window:
# cd /opt/HWICMR/bin
# ./install.sh
Select the installation type. The installation wizard will guide you through
the rest of the installation process according to the installation type you
selected.
Select[1]:
Step 3 Enter 1.
The terminal displays:
======= Host Name =======
Host name is the only ID of the host. It is the name used to indicate the
host in the network. Host name for each host is unique in the network.
Press Enter to use the current host name, or enter a new host name.
The new host name will take into effect after the host reboots.
The host name can contain numerals, letters, dots, minus signs, and
underlines. It must begin with a letter or an underline, and end with a letter or
numeral.
Enter[client1]:
1. bge0
2. bge1
3. bge2
4. bge3
Select[1]:
NOTE
l The system automatically detects the names of network cards. These names given above may vary with
the hardware. For example, ce, eri, bge, and so on. If you press Enter directly, the system uses the
network card represented by the number within the bracket.
l The prompt information given above is not displayed if the workstation has only one network card.
Step 5 Enter 1.
Enter[129.9.1.234]:
Enter[255.255.255.0]:
Step 7 Enter the subnet mask address as previously planned, for example, 255.255.255.0.
The terminal displays:
======= Information Confirmation =======
Confirm[Y]:
Step 8 Enter Y.
The terminal displays:
======= Install SYBASE Software =======
Enter[Y]:
Step 9 Enter N.
The terminal displays:
======= SYBASE Installation Directory =======
Enter[/opt/sybase]:
Confirm[Y]:
Step 11 Enter Y.
The terminal displays:
======= Install OptiX iManager T2000 =======
Enter "Y" to install the T2000 software. Enter "N" to skip this step.
Enter[Y]:
Step 12 Enter Y.
The terminal displays:
======= OptiX iManager T2000 Installation Directory =======
Enter[/T2000]:
Select (You can select multiple items and separate them with spaces.)[1 2]:
Step 14 Enter 1.
Confirm[Y]:
Step 15 Enter Y.
Acquire the software package from the CD-ROM or from the hard disk?
Name of Software Package: t2000v200r005c01.tar.bz2
Option 1: From the CD-ROM
Option 2: From the hard disk. The path of the software package is
required.
1. CD-ROM
2. Hard disk
Select[1]:
NOTE
l To install the T2000 client from the hard disk, make sure the t2000v200r005c01.tar.bz2 file
(uncompressed from the t2000v200r005c01b0xxen_unix_cd2.tar package) is available.
l The installation program automatically searches for the t2000v200r005c01.tar.bz2 file in the /export/
disk2 directory. If the file is already there, the program automatically starts the installation. Otherwise,
enter the path of the file.
Step 16 Enter 1.
Step 17 Insert the T2000 installation CD-ROM #2 (OptiX iManager T2000 application CD-ROM), and
press Enter.
The installation of the T2000 software starts. After the installation, the terminal displays:
Install OptiX iManager T2000 software..........................Done
Configure OptiX iManager T2000 software........................Done
......
All operation logs are saved in:
/var/ICMR/ICMR_LOG_20071110162217
Step 19 Log in to the system as user t2000. If you log in to the system as t2000 for the first time, the
system prompts you to set the password. After that, the login interface is displayed again.
Step 20 Log in to the system as user t2000. The system prompts you to select the default desktop.
Step 21 Select Common Desktop Environment (CDE). Then click OK.
NOTE
To ensure the system security, regularly modify the password of user t2000 by using the passwd t2000
command. The password should not be less than eight characters.
----End
Procedure
Step 1 Right-click a blank area of the desktop and choose Tools > Create Action from the shortcut
menu. The Create Action dialog box is displayed.
CAUTION
Pay attention when you type the program path, as it is case-sensitive.
Step 3 Choose File > Save to save the new action (saved in the start directory). Then close the Create
Action dialog box.
Step 4 Right-click a blank area of the desktop and choose the Folders > File Manager - Home from
the shortcut menu. The File Manager dialog box is displayed.
Step 5 Right-click the T2000Client icon and choose Put in Workspace from the shortcut menu. On
the desktop, the T2000 shortcut icon is displayed, indicating that the process was successful.
----End
Prerequisite
The T2000 server and client must be installed.
7.5.1 Uploading NE Configuration Data
The NE configuration data in the T2000 may differ from that in the NE. During maintenance,
you need to keep the data in the T2000 consistent with the data in the NE. If the network runs
normally and the data in the NE is correct, upload the data from the NE to the T2000. After
uploading, you need to perform a consistency check.
7.5.2 Checking Consistency of Configuration Data Between an NE and the T2000
A consistency check is done to compare the configuration data in the NEs with the data in the
T2000. After the check, a report of the result is created. If the result shows the configuration
data is inconsistent, you need to upload the configuration data from the NE to the T2000 or
download the data from the T2000 to the NE for data synchronization.
7.5.3 Viewing Current NM Alarms
By viewing the current NM alarms, you can query the status of the T2000 and whether the
communication between the T2000 and NEs is normal. When you view all the current alarms
on the T2000, you can perform other operations for these alarms at the same time. For example,
synchronize, refresh, check, acknowledge and filter alarms.
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs from the Object Tree and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Upload. Alternatively, right-click and select Upload from the shortcut menu.
Step 5 Click OK in the confirmation dialog box.
Step 6 Click Close in the Operation Result dialog box.
----End
Prerequisite
You must be an NM user with "NE and network operator" authority or higher.
Context
l Configuration data consistency check between the T2000 and NEs does not change the
configuration data in the NEs and in the T2000.
l To ensure that the T2000 properly manages the NEs, it is recommended that you run this
function on a monthly basis to keep the consistency of configuration data in NEs and the
T2000 server.
Procedure
Step 1 Select Configuration > Configuration Data Management from the Main Menu.
Step 2 Select one or more NEs in the left pane and click the double-right-arrow button (red).
Step 3 Select one or more NEs from the Configuration Data Management List.
Step 4 Click Consistency Check. Alternatively, right-click the NE and select Consistency Check from
the shortcut menu.
l If the result indicates an inconsistency in the configuration data between the NE and the T2000, you
need to upload or download the data to achieve consistency.
l Click Save As to save inconsistent information to a file.
----End
Prerequisite
To view the alarms, you must be an NM user with the "NE and Network Monitor" authority or
higher. To acknowledge, check, synchronize or delete alarms, you must be an NM user with the
"NM Monitor" authority or higher.
Procedure
Step 1 Right-click the local NM icon on the Main Topology and choose Browse Current Alarms. The
current NM alarms of all severity levels are displayed.
You can also choose Fault > Browse Current Alarms from the Main Menu and select the local
NM to view the current NM alarm.
Step 2 If you want to display the latest alarms, check the Display the Latest Alarms check box.
NOTE
The function of the checked check box is equivalent to the refresh function. Thus, when the check box is
checked, the Refresh button is grayed out.
Step 3 To query alarms by certain criteria, click Filter, and the Filter dialog box is displayed.
NOTE
If you check the Display the Lasted Alarms check box, in the Filter dialog box that is displayed, the
Cleared Time filter criteria is not available.
Step 4 Set the filter criteria, such as Alarm Name, Remark, Rising Time, Alarm Status, Alarm
Severity, Alarm Type and so on. Then, click Filter to filter the alarms.
The alarm information is displayed according to the criteria you set.
Step 5 Optional: Select one or more alarms, and click Check to check the selected alarms.
NOTE
An alarm check helps you to confirm the status of the uncleared alarms. It also clears the alarms that are
actually cleared but still are uncleared in the NM alarm library.
Step 6 Select an alarm. Its details and causes are displayed in the table below.
Step 7 Select one or more alarms and click Acknowledge. The Operation Result dialog box is
displayed.
Step 8 Click Close. The corresponding parameter values are displayed in the Ack Time and Ack
User fields.
NOTE
Acknowledged and cleared alarms automatically change to history alarms.
Step 9 Select one or more alarms and click Delete. The Delete Alarms dialog box is displayed. Click
Yes.
The progress bar about the alarm deletion is displayed.
Step 10 Click Yes in the Operation Result dialog box.
Step 11 Optional: Click Print or Save As to output the alarm data.
----End
You can uninstall the T2000 software from the Windows or the UNIX operating system.
Prerequisite
The T2000 and the database must be shut down.
Procedure
Step 1 To delete the T2000, do as follows:
1. Run the following commands to delete the T2000 software.
# cd /T2000
# rm -rf *
4. Run the following command to delete the user t2000 in the home directory.
# rm -rf /export/home/t2000
7. Run the following commands to delete the installation log or the operation log.
# cd /var/ICMR
# rm -rf *
----End
Result
After you complete these steps, the T2000 is successfully deleted.
Procedure
Step 1 Choose Start > Settings > Control Panel. The Control Panel window is displayed.
Step 2 Double-click Add/Remove Programs. The Add/Remove Programs window is displayed.
Step 3 Select iManager T2000, and click Change/Remove.
----End
Result
After you complete these steps, the T2000 is successfully deleted.
9 FAQ
This chapter describes how to troubleshoot the common problems in the installation procedure.
To connect the T2000 to the upper NMS, you must enable the corresponding northbound
interface.
9.11 Identifying Network Card Name
You can follow the procedure described as follows to identify the network card name that
corresponds to each network port.
9.12 How to Change the IP Address
You need to change the IP address if the site network environment or the configuration changes.
Follow the steps below to change the IP address of the workstation.
9.13 How to Change the Host Name
When changing the host name of the workstation, follow the steps below to ensure effective
operations and the security of the equipment.
9.14 About Time Zones
This section describes the files about time zones in the workstation.
9.15 Command Failure Caused by an Improper Terminal Windows Size
Solutions to misoperation of the commands caused by misconfiguring the size of the terminal
window.
Prerequisite
You must have the authority of user root.
Procedure
Step 1 Log in to the Solaris operating system as user root.
Step 2 Run the following commands to enable the telnet authority of user root:
# svcadm enable telnet
# sed "/^CONSOLE/s//#CONSOLE/g" /etc/default/login > /tmp/login
# cp /tmp/login /etc/default/login
----End
Prerequisite
You must have the authority of user root.
Procedure
Step 1 Log in to the Solaris operating system as user root.
Step 2 Run the following commands to enable the FTP authority of user root:
# svcadm enable ftp
# sed "/^root/s//#root/g" /etc/ftpd/ftpusers > /tmp/ftpusers
# cp /tmp/ftpusers /etc/ftpd/ftpusers
----End
Context
There are two database service processes: dataserver and backupserver.
Procedure
Run the following command:
# /opt/sybase/ASE-12_5/install/showserver
Check whether the dataserver and backupserver are running. If not, the database service
processes fail to be started.
----End
Procedure
Step 1 Run the following commands to open the Sybase license manager window:
# cd /opt/sybase/SYSAM-1_0/bin
# ./lmgr
Step 2 Enter the information as prompted on the screen according to the requirements in the license of
Sybase.
----End
Prerequisite
You must log in to the Solaris system as user root.
Procedure
Step 1 Open a terminal window in the Solaris system.
Step 3 Run the following command to check whether the database is started.
$ ./showserver
----End
Prerequisite
Log in to Solaris as user root.
Procedure
Run the following commands to shut down the Sybase database.
# su - sybase
$ cd /opt/sybase/OCS-12_5/bin
$ ./isql -ST2000DBServer -Usa -Ppassword_of_user_sa -zus_english
NOTE
If you did not set the password of user sa, the default password is null.
1> shutdown SYB_BACKUP
2> go
1> shutdown
2> go
To check whether the database is shut down, refer to 9.3 How to Check Whether Sybase
Service Process Is Started.
----End
Procedure
Step 1 Run the following commands:
% cd /T2000/server/bin
% ./showt2000server
Step 2 Check whether the following processes are running: sysmoniter, mdp, security, toposvr,
schedulesrv, syslog agent, weblct and ems.
l If any of these processes has only one process ID each, it indicates that the server has already
been booted up.
l If a process is found absent, it indicates that the server has not been booted up completely.
l If a process has two or more IDs, it indicates that the server has been started repeatedly.
On the last two occasions mentioned above, you should run the /T2000/server/bin/
shutdownserver command to shut down the server, and then restart the server.
----End
Procedure
Step 1 Run the following commands:
% cd /T2000/smclient
% ./smclient.sh
Step 3 Choose System > Shutdown System from the menu of the System Monitor.
CAUTION
It usually takes five to six minutes to shut down the server, because the server needs to complete
operations that are not finished yet. During the process, do not start the T2000 server again.
Step 4 Optional: To shut down T2000 forcibly, run the following commands:
% cd /T2000/server/bin
% ./shutdownserver
NOTE
Shutting down the T2000 server forcibly may leave some data unsaved. Do not use this method unless the
server startup is incomplete, or the system is collapsed.
----End
Prerequisite
In UNIX, only user root can shut down the system. Other users can use the su command to
switch to user root and then shut down the system.
Procedure
Take the following steps to shut down the workstation properly:
1. Stop the application programs including the T2000 program.
2. Open a command terminal. If you logged in as user root, skip to next step; otherwise, enter
the su command and enter the password of user root as prompted.
3. Run the following command:
# /usr/sbin/shutdown -y -g0 -i5
----End
Procedure
Step 1 To enable the northbound interface on UNIX, refer to 4.6 Enabling the Northbound Interface
(Optional).
Step 2 To enable the northbound interface on Windows, refer to the following:
l To enable the MML interface, refer to 5.4 Enabling the MML Interface (Optional).
l To enable the CORBA interface, refer to 5.5 Enabling the CORBA Interface
(Optional).
l To enable the SNMP interface, refer to 5.6 Enabling the SNMP Interface (Optional).
----End
Prerequisite
l If the workstation is not equipped with any display device, use serial port cables to connect
the workstation so that you can perform remote operations.
l Ensure that the tags are available for you to label the identified network port.
Procedure
Step 1 Log in as user root, and open a terminal.
Step 2 Run the following command to start the network card.
# ifconfig bge0 plumb
NOTE
l You must enable all network cards. In this example, the network card name is bge0.
l After the preconfiguration for the installation is complete, you can run the following commands to
query the names of all network cards of the workstation.
# cd /opt/HWICMR/bin
# ./runtaskflow.sh querynic.tf
Step 3 Run the following command to trace the change of the messages file:
# tail -f /var/adm/messages
NOTE
The information displayed on the screen varies with the actual situations. In this example, "bge0" is name
of the network card. The network cable is removed and reconnected to the port on the network card.
Step 7 Repeat this procedure to identify and label the corresponding network card of each network port
of the workstation.
----End
Procedure
Step 1 Shut down the T2000 server and database. Refer to section 9.8 How to Shut Down T2000
Server on UNIX and section 9.6 How to Manually Shut Down the Database Server.
Step 3 Open a terminal window. Choose Options > Font Size > Default , and then choose Options
> Window Size > 132×24 from the menu to adjust the terminal window accordingly.
CAUTION
The number and names of the network cards must be consistent with the original configuration
during installation.
----End
Context
CAUTION
Make sure that the operation of changing host name does not affect other applications. Back up
the files to be modified before this operation.
Procedure
Step 1 Shut down the T2000 server and database. Refer to section 9.8 How to Shut Down T2000
Server on UNIX and section 9.6 How to Manually Shut Down the Database Server.
Step 2 Log in to the system as user root.
Step 3 Open a terminal window. Choose Options > Font Size > Default , and then choose Options
> Window Size > 132×24 from the menu to adjust the terminal window accordingly.
Step 4 Run the following commands:
# cd /opt/HWICMR/bin
# ./changehostname.sh
Enter the new host name as prompted on the screen.
Step 5 Run the following commands to restart the workstation.
# sync;sync;sync;sync;sync
# shutdown -y -g0 -i6
----End
To select a time zone for a country not specified in this list, select the region containing this
country. For example, if France is not included in the list and you select France during
installation, the system generates the WET (west Europe) time instead. However, this time is
incorrect.
You can use the following method to generate the local time in Solaris 10.
In /usr/share/lib/zoneinfo/src, there are some .txt files to record the time zone setting rules of
each country. For example, the europe file gives the following time setting rules for Romania.
# Romania
# Rule NAME FROM TO TYPE IN ON AT SAVE
LETTER/S
Rule Romania 1932 only - May 21 0:00s
1:00 S
Rule Romania 1932 1939 - Oct Sun>=1 0:00s 0
-
Rule Romania 1933 1939 - Apr Sun>=2 0:00s
1:00 S
Rule Romania 1979 only - May 27 0:00
1:00 S
Rule Romania 1979 only - Sep lastSun 0:00
0 -
Rule Romania 1980 only - Apr 5 23:00
1:00 S
Rule Romania 1980 only - Sep lastSun 1:00
0 -
Rule Romania 1991 1993 - Mar lastSun 0:00s
1:00 S
Rule Romania 1991 1993 - Sep lastSun 0:00s
0 -
# Zone NAME GMTOFF RULES FORMAT [UNTIL]
Zone Europe/Bucharest 1:44:24 - LMT 1891 Oct
1:44:24 - BMT 1931 Jul 24 # Bucharest
MT
2:00 Romania EE%sT 1981 Mar 29 2:00s
2:00 C-Eur EE%sT 1991
2:00 Romania EE%sT 1994
2:00 E-Eur EE%sT 1997
2:00 EU EE%sT
For each of these .txt files, Solaris 10 provides a time zone compiler zic to generate the
geographical information of the corresponding countries. For example, using the zic file to
compile the europe file will generate an Europe subdirectory in /usr/share/lib/zoneinfo. This
subdirectory contains the following information:
Amsterdam Bucharest Kaliningrad Minsk Samara Tirane
Andorra Budapest Kiev Monaco San_Marino Vaduz
Athens Chisinau Lisbon Moscow Sarajevo Vatican
Belfast Copenhagen Ljubljana Oslo Simferopol Vienna
Belgrade Dublin London Paris Skopje Vilnius
Berlin Gibraltar Luxembourg Prague Sofia Warsaw
Bratislava Helsinki Madrid Riga Stockholm Zagreb
Brussels Istanbul Malta Rome Tallinn Zurich
On this basis, European time zone information becomes usable. For example, to set the Romania
time, just change the TZ line in /etc/TIMEZONE to "TZ=Europe/Bucharest". Then, the local
time is displayed after the computer is restarted.
Similarly, the time zone information of Asian countries can also be compiled. According to this
Solaris principle, if there is no time zone information about a country or region, you can create
a time zone setting rules file in the same format and then use zic to compile the file into time
zone information.
Context
If some commands fail to be issued, a message is displayed saying "The terminal columns are
less than 132. Adjust the width of terminal, and then execute again." or "The terminal rows are
less than 24. Adjust the length of terminal, and then execute again."
Procedure
Choose Options > Font Size > Default, and then choose Options > Window Size > 132×24
from the menu to adjust the terminal window accordingly.
----End
The following describes the T2000 license file and how to obtain, install and use the T2000
license.
Precautions
l A T2000 license exists in the form of text file. The file name is in the format of
licenseXXXXXXX.txt.
l One license file corresponds to the MAC address of the network card of a T2000 computer,
which can only be used on the corresponding computer.
l For the server that has multiple network cards, obtain the license for only the network card
that is used by the T2000.
l Never make any modifications to the license file. Otherwise, the license will fail.
l Make sure there is only one license file in the server directory of the T2000.
l On UNIX, FTP the license file to a workstation as user t2000 in the mode of ASCII.
l The license of the T2000 V200 is incompatible with that of the T2000 V100. If you have
upgraded the T2000, reapply for a license.
l The items that the license supports vary with different versions of the T2000. You must
use the application form template specific to that T2000 version when applying for the
license.
Context
l The T2000 license file is not sent to the customer with the T2000 installation CD-ROM,
but is applied by the Huawei engineer according to the contract number and the MAC
address.
l When users need to change the T2000 computer server or increase the management
capability of the server, they need to feed back the MAC address and the contract number
to a Huawei engineer for the T2000 license.
l The Huawei engineer applies for a T2000 license according to the contract number and the
MAC address.
Procedure
Step 1 Get the contract number in project documents.
In Windows XP:
In Solaris 10:
1. Open a Terminal.
2. Run the following command to switch to user root:
% su - root
NOTE
Enter the password of user root according to the screen prompt. The default password is rootkit.
3. Run the following command to view the MAC address:
# ifconfig -a
Step 3 Send the contract number and the MAC address to a Huawei engineer or the nearest branch.
Step 4 The Huawei engineer fills in the application form to obtain a T2000 license.
Step 5 After the Huawei engineer obtains the T2000 license, she or he sends it to the customer.
----End
Prerequisite
The T2000 license file is ready.
Context
To install the T2000 license, you can copy the license file to the server directory of the T2000.
NOTE
l If the T2000 server is installed on UNIX, copy the license to the $IMAP directory (the default directory
is /T2000/server).
l If the T2000 server is installed on Windows, copy the license to the %IMAP% directory (the default
directory is C:\T2000\server).
Procedure
Step 1 Exit all the T2000 client software.
Step 3 On the computer of the T2000 server, copy the authorized license file to the server installation
directory.
l On the UNIX platform, FTP the license file to the $IMAP directory in the ASCII mode as
user t2000.
l On the Windows platform, copy the license file to the %IMAP% directory.
Then the license can take effect. Choose Help > About from the Main Menu and then click
License Information to check the license information when the T2000 client is started.
----End
Context
NOTE
Do not modify the name, the content, or the format of the license file. Otherwise the license will be invalid.
If the license file is invalid, follow the procedure described as follows to check the correctness
of the license.
Procedure
l Check the correctness of the license on UNIX.
1. Run the following command to get the MAC address of the host computer.
# ifconfig -a
The characters that follow "ether" is the MAC address of the network card. The MAC
address format is xx:xx:xx:xx:xx:xx, where xx is one or two hexadecimal numbers.
NOTE
You must uses ifconfig -a command as user root to get the MAC address of the host computer.
2. View the license file by the more command.
# cd /T2000/server
# more licenseXXXXXXX.txt
License = A26F90385ACE5FD947F057C36786A4C5E33E1C854AB410A11292
0687F007548AF4A586BBE902313F309F6A82DD19
The characters that follow "MAC=" is the MAC address of the network card that
corresponds to the license. Check whether the two MAC addresses are the same or
not. If not, get the appropriate license file.
3. Make sure that $IMAP/imapgetmac is owned by root, and the permission is 4755.
4. Check whether the text mode, namely ASCII mode, is adopted to transfer the license
file.
NOTE
To check the transfer mode, open the licenseXXXXXXX.txt file at the workstation by the vi
command. If every line is ended with "^M", it indicates that the transfer mode is incorrect, and
the transfer should be repeated in the mode of ASCII.
l Check the correctness of the license on Windows.
1. Choose Start > Programs > Accessories > Command Prompt to start a command
terminal. Run the following command.
ipconfig /all
The characters that follow "Physical Address" is the MAC address of the network
card.
2. Open the license file.
The screen displays:
......
SupportIPEndToEnd = 1
SupportLct = 1
SupportMDSXMLFileIF = 1
SupportOAMS = 1
SupportOpticWdmAson = 1
SupportPrefabTrail = 1
SupportRTN = 1
......
MAC = 00:16:EC:3F:53:CC
License =
A26F90385ACE5FD9556281DF02A5568066BBF2CF80CC7AAE2427D0C32623FC6452F1F31F7
095722DAF3B3490BE5A5B7C67FDEBA9A49F34E96C5D8E7F1D8F590B14963DBAC644C68AE1
C44B972C68D9B4B16AE9455C2BA60CC8A9559727BB6BAD10262D.......
The characters that follow "MAC=" is the MAC address of the network card that
corresponds to the license. Check whether the two MAC addresses are the same or
not. If not, get the appropriate license file.
3. Check whether the network adapter is available or not.
– If not, the MAC address cannot be detected, and the license will be invalid. Check
whether there is any error during the transfer of the license.
– If yes, re-transfer the license file and store it in the C:\T2000\server directory. Re-
activate the T2000 to see whether it is valid.
----End
B Disk Mirror
This appendix describes how to create and maintain disk mirror. It also describes the common
operations about disk mirror.
Prerequisite
l The workstation contains two hard disks with the same capacity.
l Only the first hard disk is partitioned.
l A 30 MB space has been allocated for slice 4 of the boot disk.
l The T2000 for UNIX installation CD-ROM is ready.
Procedure
Step 1 Log in to the system as user root. Insert the T2000 installation CD-ROM #1 (System patches
CD-ROM).
l For the Solaris 8 operating system, run the following command:
# cp /cdrom/cdrom0/setup_mirror_s8.sh /setup_mirror.sh
Step 3 Enter y.
The terminal displays:
Disk Mirror is set up successfully! Please reboot to resync mirror!
Step 5 Log in to the system as user root and run the following command to run the script of disk mirror
creation again:
# sh /setup_mirror.sh
The disk mirror is being synchronized, and this process takes about six hours.
Step 6 Wait until the terminal displays:
Mirror Resync completed!
# /usr/sbin/metastat -p
When the following prompt is displayed, disk mirror is successful. Note that the logical name
of the hard disk may vary with the computer type.
d1 -m d11 d12 1
d11 1 1 c1t1d0s0
d12 1 1 c1t2d0s0
d2 -m d21 d22 1
d21 1 1 c1t1d0s1
d22 1 1 c1t2d0s1
d3 -m d31 d32 1
d31 1 1 c1t1d0s3
d32 1 1 c1t2d0s3
d4 -m d41 d42 1
d41 1 1 c1t1d0s7
d42 1 1 c1t2d0s7
----End
B.2.1 Checking the Configuration and Status of the State Database Replica
This command is used to display the number of state database replicas created, the status, and
the corresponding physical partitions.
B.2.2 Checking Mirror Configurations
This command is used to display the mirroring relations and submirror-partition relations.
B.2.3 Checking the Mirror Status
This section describes how to check the mirror status.
B.2.4 Creating a State Database Replica
This section describes how to create a state database replica.
B.2.5 Deleting State Database Replica
This section describes how to delete a state database replica.
B.2.6 Creating Mirrors and Submirrors
This section describes how to create mirrors and submirrors.
B.2.7 Creating Mirror root
Procedure
Run the following command:
# /usr/sbin/metadb -i
This command is used to display the number of state database replica and the physical partition
they are located as well as their status. For details of the command, use metadb -h.
----End
Procedure
Run the following command:
# /usr/sbin/metastat -p
d31 1 1 c0t1d0s3
d32 1 1 c0t0d0s3
d4 -m d41 d42 1
d41 1 1 c0t1d0s7
d42 1 1 c0t0d0s7
This command is used to display the mirroring relations and submirror-partition relations. For
example in the previous output, there are four mirrors d1 – d4, among which d1 has two
submirrors, that is, d11 in partition c0t1d0s0 and d12 in c0t0d0s0. The name of physical partition
varies with the actual computer mode. For details of the command, use metastat -h.
----End
Procedure
l Run the following command to obtain the status of all submirrors and mirror.
# /usr/sbin/metastat
l Run the following command to obtain the status of d11 and d12.
# /usr/sbin/metastat d11 d12
The command varies with the specific situation. For details, use metastat -h.
----End
Procedure
Run the following command:
# /usr/sbin/metadb -afc 3 c0t0d0s4
This command is used to create the basic state database replica for mirroring on physical partition
c0t0d0s4. The value 3 means to create three state database replicas. For details, use metadb -
h.
----End
Procedure
Run the following command:
# /usr/sbin/metadb -f -d 3 c0t0d0s4
This command is used to delete the state database replicas on the physical partition. For details,
use metadb -h.
----End
Procedure
Run the following commands:
# /usr/sbin/metainit -f d11 1 1 c0t0d0s0
# /usr/sbin/metainit d12 1 1 c0t0d1s0
These two commands are used to create submirror d11 in partition c0t0d0s0 and submirror d12
in c0t1d0s0 respectively.
# /usr/sbin/metainit d1 -m d11
This command is used to create a mirror d1 with submirror d11. For details, use metainit -h.
----End
Procedure
Run the following command:
# /usr/sbin/metaroot d1
If mirrors are created on the /file system, you must use the metaroot command to boot the Solaris
system by the mirrors.
NOTE
The metaroot command automatically modifies the /etc/system and /etc/vfstab files. Using it incorrectly
may make the system unable to boot. To boot the system by physical partitions, run the following command:
# /usr/sbin/metaroot c0t0d0s0
----End
Procedure
Run the following command:
# /usr/sbin/metaclear -a -f
This command is used to clear all submirrors and mirrors. If the system is already mounted on
the mirror, the clearing cannot succeed. To clear the mirrors and submirrors successfully, you
have to separate the submirrors from the mirrors and mount the file system in the partition. For
details, use metaclear -h.
----End
Context
If this problem occurs, the following information is displayed:
Insufficient metadevice database replicas located.
Use metadb to delete databases which are broken.
Ignore any "Read-only file system " error messages.
Reboot the system when finished to reload the metadevice database.
After reboot, repair any broken database replicas which were deleted.
Type control-d to proceed with with normal startup,
(or give root password for system maintenance):
Procedure
Step 1 Enter the password of user root, and Solaris gets into the single-user mode.
Step 2 Run the following commands.
# cd /usr/sbin
# ./metadb
Step 3 The lines stamped unknown above refer to state databases that cannot be found. Run the
following command to delete them.
# /usr/sbin/metadb -d c0t1d0s4
NOTE
The c0t1d0s4 refers to the hard disk partition mentioned in the unknown line. It varies with the computer.
----End
Context
After the disk mirrors are mounted, the failure or removal of a hard disk will make the system
unable to boot. The following system prompt is displayed.
Insufficient metadevice database replicas located.
Use metadb to delete databases which are broken.
Ignore any "Read-only file system " error messages.
Reboot the system when finished to reload the metadevice database.
After reboot, repair any broken database replicas which were deleted.
Type control-d to proceed with with normal startup,
(or give root password for system maintenance):
Procedure
Step 1 Enter the password of user root, and Solaris gets into the single-user mode.
Step 2 Run the following commands.
# cd /usr/sbin
# ./metadb
Step 3 The lines stamped unknown above refer to state databases that cannot be found. Run the
following command to delete them.
# /usr/sbin/metadb -d c0t1d0s4
NOTE
The c0t1d0s4 here corresponds to the hard disk partition in the system outputs. It varies with the computer.
Step 6 Run the following commands to detach the submirrors on the failed hard disk from the mirror.
From the outputs of the metadb command, you can know the hard disk c0t1d0 has failed and
thus you have to detach d11 (c0t1d0s0), d21 (c0t1d0s1), d31 (c0t1d0s3), and d41 (c0t1d0s7).
# /usr/sbin/metadetach -f d1 d11
# /usr/sbin/metadetach -f d2 d21
# /usr/sbin/metadetach -f d3 d31
# /usr/sbin/metadetach -f d4 d41
Step 8 Replace the hard disk with a new one of the same capacity.
Step 9 Restart the computer.
Step 10 Partition the new hard disk. Run the following command to back up the partition table of the
first hard disk partition.
# prtvtoc /dev/dsk/c0t0d0s2 > /tmp/c0t0d0.vtoc
Then run the following command to write the partition table of the first hard disk partition to
the other hard disk.
# fmthard -s /tmp/c0t0d0.vtoc /dev/rdsk/c0t1d0s2
CAUTION
This step writes the partition information of the good hard disk, c0t0d0, to the new one, c0t1d0.
In the example above, the partition information of c0t0d0 is written into c0t1d0.
NOTE
This example is based on the assumption that the state database replicas are on c0t1d0s4. They can also be
on another partition.
Step 12 Run the following commands to attach the detached submirror to the mirror again.
# /usr/sbin/metattach d1 d11
# /usr/sbin/metattach d2 d21
# /usr/sbin/metattach d3 d31
# /usr/sbin/metattach d4 d41
Then the system starts mirror synchronization. The completion of this process also means the
completion of the hard disk replacement.
Step 13 Run the following command to check whether the synchronization is complete.
# /usr/sbin/metastat d1
This command checks mirror d1 only. Other mirrors can be checked the same way.
The terminal displays:
d1: Mirror
Submirror 0: d11
State: Okay
Submirror 1: d12
State: Okay
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 5640264 blocks
d11: Submirror of d1
State: Okay
Size: 5640264 blocks
Stripe 0:
Device Start Block Dbase State Hot Spare
c0t1d0s0 0 No Okay
d12: Submirror of d1
State: Okay
Size: 5640264 blocks
Stripe 0:
Device Start Block Dbase State Hot Spare
c0t0d0s0 0 No Okay
Check the State items to make sure they are all Okay, which means the mirror synchronization
is complete.
----End
Procedure
Step 1 Check the mirror configuration.
Run the following command:
# /usr/sbin/metadb
This command displays the relations between the mirrors, submirrors, and physical partitions.
For example, the above outputs include the following information. There are four mirrors d1-
d4. d1 has two submirrors d11 and d12. d11 is partition c0t1d0s0 and d12 is partition c0t0d0s0.
Run the following commands to detach the submirrors according to the above system outputs.
# /usr/sbin/metadetach d1 d12
# /usr/sbin/metadetach d2 d22
# /usr/sbin/metadetach d3 d32
# /usr/sbin/metadetach d4 d42
Step 3 Run the following command to boot the /file system by physical partitions.
# /usr/sbin/metaroot c0t0d0s0
Manually modify or overwrite the /etc/vfstab file with the backup vfstab file saved in the mount
file system of the physical partition.
Step 6 Run the following command to delete all submirrors and mirrors.
# /usr/sbin/metaclear -a
Step 7 Run the following command to delete the state database replicas.
# /usr/sbin/metadb -f -d c0t0d0s4 c0t1d0s4
----End
Context
Otherwise, if you boot the system directly, the following system prompt is displayed.
mount:/dev/dsk/c0t0d0s0 is not this fstype.
Failed to open /etc/coreadm.confsyseventd: Unable to open daemon lock file
'/etc/sysevent/syseventd_lock':'Read-only file system' ln: cannot create
/dev/fb:Read-only file system
INIT: cannot create /var/adm/utmpx
INIT: failed write of utmpx entry:” “
INIT: failed write of utmpx entry:” “
INIT:SINGLE USER MODE
Type control-d to proceed with with normal startup,
(or give root password for system maintenance):
Procedure
Step 1 Run the following commands:
# sync;sync;sync;sync;sync
# shutdown -y -g0 -i0
Step 2 Run the following command under the ok prompt to boot the system to the single-user mode.
ok boot cdrom -s
----End
This appendix describes related precautions, service ports of the T2000, and how to query the
service ports.
C.1 Background
This section describes the service ports used by the T2000.
C.2 Notes and Precautions
In the practical communication process, the source (the server) and the sink (the client) use
relevant ports. Usually you only need to specify the source port, and the sink port is dynamically
created.
C.3 Service Ports Used by the T2000
This section describes service ports of the system.
C.4 How to Query Service Ports
This section describes how to query the service ports.
C.1 Background
This section describes the service ports used by the T2000.
To ensure the network security, you can take measures on the customer's network. The following
are the two cases that affect the network security:
l Security filtering settings such as routers or firewalls are configured in the network
environment where the T2000 runs. When carrying out the project, make sure that the
service ports used by the T2000 are not filtered out according to the security settings.
l Some service ports providing system services are closed to prevent network or virus attacks.
Note that the service ports used by the T2000 should not be closed. Otherwise, the
T2000 does not run properly.
Procedure
Run the following command to view the system service ports:
netstat -an
----End
This appendix describes the usage and functions of the commonly used Solaris system
commands.
Command/Usage Function
Command/Usage Function
Command/Usage Function
Command/Usage Function
Command/Usage Function
tar [function_options [modify_option]] [file] Utility program for file backup and
restoration.
bc Calculator
Command/Usage Function
Command/Usage Function
This appendix describes how to forward alarms to an external system by using email or short
messages.
Prerequisite
You must be an NM user with "NM monitor" and "NE and network operator" authority or higher.
Procedure
Step 1 Choose Fault > Set Alarm Notification from the Main Menu.
Step 2 In the Set Alarm Notification window, click Create to add a new alarm notification.
Step 3 Set the Communication Mode to EMAIL and specify an email address in the Communication
Number/Email Address field.
Step 4 Set the parameters such as User Name, Send Duration and Switch one by one.
Step 5 Click the Filter Criteria tab and click Select Object.
Step 6 In the Select Object dialog box that appears, select one or multiple monitored objects.
Step 7 Select an object from the Monitored Object list and set filter criteria for it.
Alarm Attribute Set the Severity and Type for the alarms to be filtered.
Alarm Name Click Alarm Settings and add alarm events in the dialog box that appears.
Step 8 Click the Preview Custom Field tab to set the alarm notification information to be displayed.
NOTE
You can preview the format of the alarm information on the right-hand pane.
----End
Context
Only the Windows operating system supports alarm notifications by short message. This section
describes how to install the alarm notification software in Windows XP. For the procedures for
installing the software in other Windows platforms, refer to this section, because the procedures
are similar.
E.2.1 Installing e-TEK TD-8011 GSM MODEM
Currently, short messages can be sent to a mobile phone by using the e-TEK TD-8011 GSM
MODEM. The TD-8011 GSM MODEM is connected to the T2000 server computer by using
the DB-9 serial port cable.
E.2.2 Installing Nokia SDK 3.0 Software
To send short messages using the Nokia mobile phone, you must install the Nokia SDK 3.0
software. After you complete the installation of the T2000 server, the installation file of the
Nokia SDK 3.0 is automatically put into the relevant directory.
E.2.3 Installing the DKU-5 Connectivity Adapter Cable Driver
To enable communication between the computer and the Nokia mobile phone by using the
DKU-5 connectivity adapter cable, you must install the driver of the DKU-5 connectivity adapter
cable.
E.2.4 Installing the Infrared Device Driver
To enable communication between the computer and the Nokia mobile phone by using the
infrared device, you must install the infrared adapter driver.
E.2.5 Checking the Correctness of Installation
When using the Nokia mobile phone to send alarm notification short message, after the
installation is complete, perform the following operations to check whether the installation is
correct.
Context
l TD-8011 GSM MODEM can only be used on a Windows platform where pc_sms.exe is
installed.
l By default, the T2000 server is installed in the C:\T2000 directory, and the pc_sms.exe
file is in the C:\T2000\sms directory on the T2000 server. In this case, start directly from
Step 4.
l If the T2000 server is installed on a UNIX workstation, a PC installed with the Windows
operating system must be connected to the UNIX workstation, and the PC and the
workstation must be in the same network segment. In this case, install TD-8011 GSM
MODEM on this PC by following Steps 1 through 3.
l For the settings after installation, refer to E.3 Automatically Forwarding Alarms to
Mobile Phone.
Procedure
Step 1 Optional: If the T2000 server is installed on a UNIX workstation, copy the sms.zip file from
the /T2000/server/tools/ directory on the workstation to a PC installed with the Windows
operating system. It is assumed that the sms.zip file is uncompressed to the C:\T2000\ directory
on the PC.
NOTE
Step 2 Optional: On a PC that is installed with the Windows operating system, add an environment
variable respectively in the User variables and System variables areas. The variable name is
IMAP, and the variable value is C:\T2000\sms.
Step 3 Optional: Open the imap.cfg file in the C:\T2000\sms directory, and modify "MDPAddress =
127.0.0.1" to "MDPAddress = IP", in which IP refers to the IP address of the UNIX workstation.
Step 4 Connect the TD-8011 GSM MODEM to the serial port of the computer using the DB-9 serial
port cable.
NOTE
The serial port of the computer is usually the external COM1 or COM2.
Step 5 After the settings is complete, navigate to the C:\T2000\sms directory. Double-click
pc_sms.exe to run the program. The initialization window is displayed. After the initialization
is complete, install the dual band external Modem.
NOTE
Sometimes the TD-8011 GSM MODEM is connected properly, but the initialization of the pc_sms.exe
fails to be started. In this case, switch off the power of the TD-8011 GSM MODEM, and power on again.
Then, run pc_sms.exe again.
----End
Procedure
Step 1 Open the sms directory in the T2000 installation directory (the path defaults to be C:\T2000
\sms). Double-click the SDK_3_0.exe file, and the Installshield Wizard is displayed.
Step 3 Choose I accept the terms in the license Agreement and click Next to start the Nokia SDK
3.0 setup.
Step 4 Choose Yes, I want to restart my computer now. and click Finish to restart the computer.
After the computer is restarted, the shortcut icon appears at the lower right corner of the
desktop, which indicates the installation of the Nokia SDK 3.0 software is complete.
----End
Procedure
Step 1 Plug one end of the DKU-5 connectivity adapter cable into the USB interface of the computer,
and the system detects the new hardware automatically.
Step 2 Choose Install from a list or specific location (Advanced) and click Next to choose your search
and installation options.
Step 3 Choose Don't search. I will choose the driver to install. and click Next to choose the device
driver you want to install for this hardware.
Step 5 Insert the DKU-5 Connectivity Adapter Cable driver disk. In the Copy manufacturer’s files
from: field, specify the Driver directory in the driver disk directory and click OK.
Step 6 Click Next to start the hardware installation.
Step 7 Click Continue Anyway, and a window is displayed indicating the completion of hardware
installation.
----End
Procedure
Step 1 Connect the infrared adapter to the USB interface of the computer. The system prompts that new
hardware is detected.
Step 2 Choose Install from a list or specific location (Advanced) and click Next to choose your search
and installation options.
Step 3 Choose Don't search. I will choose the driver to install. Click Next to select infrared device.
Step 5 In the Copy manufacturer’s files from: field, specify the sms\IrDA Driver in the T2000
installation directory (the path defaults to be C:\T2000\sms\IrDA Driver) and click OK.
Step 6 Click Next.
NOTE
If this driver has been installed before, during the process of installation, a dialog box may be displayed,
asking you to specify the path of the file to be copied. In this case, re-specify path of the file to the sms
\IrDA Driver in the T2000 installation directory. By default, the path is C:\T2000\sms\IrDA Driver.
----End
Procedure
Step 1 Check the shortcut icon in the lower right corner of the desktop (on the system tray).
Step 2 Power on the mobile phone, and connect the mobile phone to the computer.
NOTE
To set up the connection:
l Use the DKU-5 connectivity adapter cable.
l Set the infrared function to the Emit state. Aim the infrared transceiver interface at the corresponding
position of the infrared adapter.
Step 3 Double-click the shortcut icon, and the Nokia Connection Manager window is displayed.
NOTE
If you use the data wire connection, click the icon to select the serial port used by the data
wire.
Step 4 Check the model of the connected mobile phone in the Phone field. If the model appears, it is
an indication that the driver is successfully installed.
Step 5 Navigate to the sms folder in the T2000 installation directory. The sms folder is default to C:
\T2000\sms. Double-click pc_sms.exe to run the program. The initialization window is
displayed. After the initialization is complete, you can send short messages using a mobile phone.
NOTE
During the process of initialization pc_sms.exe, the information "ATCommanderWavecom Init Failed!" and
"Nokia Component Library Init Success!" is displayed. This is a normal step of detection. It does not affect
sending messages by using the Nokia mobile phone.
----End
Prerequisite
l You must be an NM user with "NM monitor" and "NE and network operator" authority or
higher.
l Currently, only the Nokia mobile phone and the e-TEK TD-8011 GSM MODEM support
alarm short messages. You are recommended to use the TD-8011 GSM MODEM and Nokia
6610 to forward the alarm information.
l For the installation of Nokia mobile phone software and TD-8011 GSM MODEM, refer to
E.2 Installing the Software Used to Forward Alarms by Mobile Phone Short
Messages.
Procedure
Step 1 Choose Fault > Set Alarm Notification from the Main Menu.
Step 2 In the Set Alarm Notification window, click Create to add a new way of alarm notification.
Step 3 Set the Communication Mode to Short Message and specify the mobile phone number in the
Communication Number/Email Address field.
NOTE
When you enter the mobile phone number, add the country code before the number.
Step 4 Set the parameters such as User Name, Send Duration, Send Count and Switch one by one.
Step 5 Click the Filter Criteria tab and click Select Object.
Step 6 In the Select Object dialog box that appears, select one or multiple monitored objects.
Step 7 Select an object from the Monitored Object list and set filter criteria for it.
Alarm Attribute Set the Severity and Type for the alarms to be filtered.
Alarm Name Click Alarm Settings, and add alarm events in the dialog box that appears.
Step 8 Click the Preview Custom Field tab to set the alarm notification information to be displayed.
NOTE
You can preview the format of the received alarm information on the right-hand pane.
Step 9 Click Communication Settings. In the dialog box that appears, specify a Mobile Phone.
NOTE
The Mobile Phone parameter refers to the communication port through which the TD-8011 GSM MODEM
or the mobile phone is connected to the computer.
----End
There are two modes for numbering VC12 timeslots in a VC4: numbering mode and interleaved
mode.
The numbering mode is recommended in ITU-T G.707. Figure F-1 shows the numbering mode.
The calculation formula for VC12 numbering by order is as follows: VC12 number = K + (L -
1) * 3 + (M - 1) * 21.
The interleaved mode is used for optimizing the VC3 trails. Figure F-2 shows the interleaved
mode.
The calculation formula for VC12 numbering in the interleaved mode is as follows: VC12
number = (K - 1) * 21 + (L - 1) * 3 + M.
G Glossary
Configuration data The data that configures the NE hardware for coordination
between this NE and other NEs in the entire network and
operation of specified services. Configuration data is the
instruction file of NEs, and it is the key for efficient network
running. The typical configuration data includes board
configuration, clock configuration and protection relationship.
Current alarms Alarms that do not clear, or has cleared but is not acknowledged.
Host name Name of the computer that functions as a main controlling point
in a network and provides special service to the users.
LCT Local Craft Terminal. The LCT provides the user with single-
layer management network solutions to the transmission
network of up to five NEs to realize integrated management of
multi-service transmission network. Usually it uses the cross-
over cable or serial port cable to connect one NE, so as to
configure and maintain a single NE. See also T2000-LCT.
Lock status The service will not be switched to the protection board when
fault occurs, if currently no switching takes place. If currently
the switching takes place, after the protected board becomes
normal, the service will not be switched to the protected board
either.
Main Topology The default T2000 client interface, and all topology
management functions are accessed here.
Network segment The range of IP addresses in which the gateway NE will operate.
Route The IP route selection is in table driving mode. In each host and
each router of the Internet, there is a routing table that contains
information about how the service is transmitted from the source
to the sink, providing a basis for route selection. Ethernet static
routing in ET1 refers to the mapping relationship between the
Ethernet port and the bound path. Its routing type includes port
routing and VLAN routing. Port routing: It means configuring
a route between the Ethernet port and the bound path port, which
is usually used for point-to-point networking communication;
VLAN routing: It means configuring a route between the
Ethernet port and the bound path port based on the VLAN
service. It can be used flexibly in point-to-point, point-to-
multipoint or multipoint-to-multipoint communication. The
implementation is to divide and converge the data stream
according to the VLAN flag of the packet. As a VLAN flag can
be added to the Ethernet port, the equipment can be applied more
flexibly.
Script file It is the text file describing the physical information and
configuration information of the entire network, including the
NE configuration file, port naming file, end-to-end
configuration file, NE physical view script file, NM information
file and service implementation data script file.
Subnet mask Also referred to as the network mask off code, it is used to define
network segments, so that only the computers in the same
network segment can communicate with one another, thus
suppressing broadcast storm between different network
segments.
User group User set refers to the set of NMS users with the same
management authorities. The default user group includes:
system administrator, system maintainer, system operator and
system supervisor. The attributes of user set include name and
detailed description.
User The user of the T2000 client, and the user and his/her password
define the corresponding authority of operation and
management of the T2000.
ID Identity
IP Internet Protocol
MO Managed Object
NE Network Element
NM Network Management
Index
A
D
alarm email notification, E-2
alarm management data consistency check between the T2000 and NE,
alarm email notification, E-2 4-25, 5-18, 6-10, 7-15
alarm short message notification, E-15 database
alarm short message notification, E-15 checking service process, 9-3
deleting disk mirror, B-10
C disk
disk configuration, 2-8
changing host name, 9-9 disk mirror, 2-8
changing IP address, 9-8 disk partition, 2-7
checking disk partition, 2-10, 7-2
correctness of installation, E-14
database running, 4-19 E
database service process, 9-3
equipment environment, 2-5 enabling
hardware, 2-4 northbound interface, 4-16
hardware installation, 3-4 environment variable, 5-13
mirror configurations, B-4 equipment cable, 3-3
mirror status, B-5
necessary software, 2-10 G
sybase user, 4-19
T2000 running status, 4-20 getting MAC address, A-2
T2000 user, 4-19
whether T2000 server is started, 9-5 H
client
creating shortcut icon, 7-12 hardware connection, 3-2
configuration data management
consistency check, 4-25, 5-18, 6-10, 7-15 I
uploading, 4-24, 5-18, 6-10, 7-15
configuration file initial user name, 5-14
ems.cfg file, 4-20, 4-21, 4-23, 5-11, 5-11, 5-12, initializing database, 5-9
5-15, 5-15, 5-17 installation
monisnmpagent.cfg, 5-17 hardware installation, 3-4
CORBA operating system, 4-2
check CORBA interface, 5-15 T2000 license, 5-10
checking CORBA interface on UNIX, 4-21 T2000 software, 4-7
enabling CORBA interface on Windows, 5-11 installation procedure, 1-1
enabling the CORBA interface, 9-7 installation tool, 2-5
creating installing
client shortcut icon, 7-12 computer, 3-2
disk mirror, 4-18, B-2 DKU-5 connectivity adapter cable driver, E-7
T2000 shortcut icon, 4-14 infrared adapter driver, E-10
planning W
IP address, 2-11
port number, 4-20 workstation time zone, 9-9
Q
querying service port, C-6
R
replacing corrupted disk, B-8
S
server
manually shutting down server, 9-4
starting the database manually, 9-4
server configuration, 2-2
service port, C-2
shutting down
workstation, 9-6