Application Worksheet
Application Worksheet
Company: Date:
Address: Phone:
Fax:
End-User: *
Contact: Final Destination: *
* Required
Rev. 21-Liquid: Orifice Meter (US) Rev. 25-Liquid: Orifice Meter (Metric Units)
Rev. 22-Liquid: Turbine/PD Meter with MF Curve (US) Rev. 26-Liquid: Turbine/PD Meter with MF Curve (Metric)
Rev. 23-Gas: Orifice/Turbine/Ultrasonic Meter (US) Rev. 27-Gas: Orifice/Turbine/Ultrasonic Meter (Metric)
(select one)–
Oils: Crude Oil Refined Products LPGs Propylene Ethylene NGLs E-P Mix
Gases: Nat. Gas Ethylene CO2 Steam N2 O2 H2 Ar2
Other:
Standard Panel Standard Panel Mount With Separate 3 Piece Assembly; Separate Keypad, card chassis (18 in
Back Panel & 5ft* Extended Cables cable between)and Back Panel with 5 ft* Extended Cables
*Standard cable length 5ft. Extended cables are optionally available in 10ft lengths.
(Only check box if you require Omni to mount the flow computer in an enclosure)
Page 1 of 2
Meter Meter Meter Meter Common/
Run #1 Run #2 Run #3 Run #4 Station
Flow Meter*
select: Turbine (T), PD Meter (PD), Pulse Fidelity (PF), Ultrasonic
(USM)#, Diff. Pres. (DP) State if 1 or 2 DP transmitters per meter run)
Coriolis Mass
select: Yes (Y) or No (N)
Temperature
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD)
Pressure
select: 4-20mA (mA) or 1-5Volts (V) or Digital (D)
Gravity
select: 4-20mA (mA) or 1-5Volts (V) or Frequency (F)
Density
select: 4-20mA (mA) or 1-5Volts (V) or Frequency (F)
Density Temperature
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD)
Additional Analog Inputs (BS&W, CO2, N2, O2 etc.)
select: 4-20mA (mA) or 1-5Volts (V)
Gas Analyzer
select: 4-20mA (mA) or RS232 (RS)
Smart Multi-Variable
select: Rosemount (SV) (modbus only) or Honeywell (HV)
*Note: Combination of Turbine and Differential Pressure inputs is only available on Rev. 23 and 27.
#Note: Please state if ultrasonic meter output is serial data, pulse or both.
Comments:
Omni Flow Computers, Inc. 12620 W. Airport Blvd., Suite 100 Sugar Land, Texas 77478 USA
Tel: 281-240-6161 Fax: 281-240-6162 Website: http:// www.omniflow.com E-mail: sales@omniflow.com
Page 2 of 2
Submit Form Reset
Omni Flow Computers, Flow Meter, Data Acquisition, Flow Computer
About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us
OMNI has gained a worldwide reputation for providing superior product quality and
customer services in flow measurement. OMNI instruments integrate easily into
your metering, flow and valve control
and system communication needs.
Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting
About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us
Hardware Solutions
OMNI Flow Computers has acquired a leading role in flow measurement technology with its
OMNI 3000 and OMNI 6000 product lines of flow computers, software, controllers and RTUs.
Software Solutions
Instruments of Choice
Major industry users specify OMNIs as their flow Training Solutions
computers of choice on many upgrade and new
projects. They recognize the versatile, built-in
functions of these instruments for measurement
and control - indispensable for pipeline, terminal,
petrochemical and process applications.
I/O boards are quality tested and temperature-trimmed to optimize analog resolution, and
burned-in before shipment for field installation.
Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting
About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us
Hardware Solutions
General Information on the Omni
Omni 3000/6000 Overview
Omni has the capability to match its standard products to
the customer's application needs. The non-restrictive I/O SmartBus Overview
bus design permits any combination of inputs and outputs
to meet most metering, flow and valve control and Literature
communication requirements.
Software Solutions
Exceptional Reliability
From components to I/O boards to operator front-panel Training Solutions
interfaces, Omni combines reliable, high-performance
hardware with software that's optimized for custody
transfer accuracy measurement and control operations.
Optical isolation all but guarantees continual performance.
With a system inherently immune to electrical noise, you
get dependability without the maintenance headaches.
That's why Omni has a three-year warranty for its
products.
Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting
About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us
Hardware Solutions
The Omni 3000 and Omni 6000 Flow Computers are reliable, easy to use, uniquely
versatile instruments. They are usually factory-programmed for single and multi-run Omni 3000/6000 Overview
configuration measuring crude oils, refined products, NGLs, LPGs, ethylene, propylene,
natural gas, and specialty gases such as O2, N2, H2,Ar, H2O, and CO2. The compact, rugged Product Details
design and operation incorporate many user-requested features that can reduce or eliminate
requirements for other ancillary control devices. Design Features
Hardware Matrix
Key Features
Model Guide
• 500 msec calculation cycle
• Photo-optical isolation of each I/O point Mounting Options
• Online Configurable SCADA data packet
• 32 bit processing with math co-processor Omni 3000/6000 Metrological
Approvals
• 4 line, alpha-numeric, backlit LCD display
• Communications to 38.4K Baud Application Worksheet
• Stored reports and data archiving
• 34 button, alpha-numeric keypad SmartBus Overview
Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting
About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us
Hardware Solutions
Photo-optical Isolation of Each I/O Point
Omni 3000/6000 Overview
The isolation of circuitry via photo-optical devices from all field wiring prevents accidental
damage to the electronics, including that caused by static electricity. The isolation also Product Details
inhibits electrical noise from inducing measurement errors. All I/O is modular and plug-in for
easy field maintenance and replacement. Design Features
Hardware Matrix
32 Bit Processing with Math Co-Processor
Model Guide
A powerful 16/32 bit, CMOS microprocessor and
32 bit floating point math co-processor are used Mounting Options
for high-speed execution of both high-level and
assembler code instructions. They provide in Omni 3000/6000 Metrological
excess of 1 MTOPS. A hardware real-time clock is Approvals
also incorporated. Time-keeping continues even
when power is lost to the Omni, which Application Worksheet
automatically resets on power-up. Time and
duration of power failure is logged, and printed SmartBus Overview
when power is restored.
Remote Meter Controller
Up to 1 Mbyte of CMOS SRAM and 1 Mbyte of Metrological Approvals
CMOS EPROM are standard on the CPU module.
All SRAM is backed up by nickel-cadmium Literature
batteries.
Software Solutions
4 line, Alpha-numeric, back-lit LCD Display
The 4 line x 20 alpha-numeric character, back-lit Liquid Crystal Display is updated every 500 Training Solutions
ms and displays all messages and system variables in English language engineering units.
Four dual-color LEDs indicate various operating modes and alarms. Three nonresettable 6
digit electromechanical counters are included on the front panel and can be programmed to
count gross, net mass or energy units at any rate up to 10 counts per second.
The keypad provides the user with a unique on-line capability to configure measurement and
control data, perform diagnostic tasks and display operator information. Context-sensitive
help screens are provided as an additional aid.
Configuration, program and diagnostic data can be entered via the keypad or remotely by
serial hook-up into battery-backed up, CMOS SRAM memory. Security codes and an internal
mechanical switch ensure that configure/program functions can be disabled when required.
Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting
About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us
Hardware Solutions
Model Number
Omni 3000/6000 Overview
The Omni 3000 is designed to accept two combo modules, one 12-channel digital I/O module
and one dual-channel serial I/O module. The Omni 6000 can accept up to six combo Product Details
modules, two 12-channel digital I/O modules and two dual channel serial I/O modules. If the
number of combo modules required, including communication boards and spare I/O's, is Design Features
greater than the Omni 3000 limits, select an Omni 6000.
Hardware Matrix
Model Guide
Mounting Options
Application Worksheet
Remember to provide for sufficient spare I/O for your computer system. A
minimum I/O system is not a manufacturer-recommended practice in important SmartBus Overview
measurement applications.
Remote Meter Controller
Combo Modules Required Metrological Approvals
'A' modules provide four input channels, two selectable as analog only input channels. The Literature
third and fourth input channels are selectable analog or pulse. Two analog outputs are
available.
Software Solutions
'B' modules provide four input channels where the first three process inputs are identical to
the 'A' module and the fourth channel is fixed to provide a periodic time density pulse input.
Training Solutions
One analog output is provided. The number of 'B' type combo modules required are equal to
the number of digital pulse densitometers that are interfacing (see type 'E/D' below).
'E' modules provide two selectable analog inputs and either two single pulse inputs or one
dual pulse input, when pulse fidelity checking is required. One double chronometry detector
switch input and two analog outputs are also provided.
'E/D' modules provide four process inputs including two analogs and two periodic time
density pulse inputs on the third and fourth channels. Two analog outputs are provided.
'H' denotes a four input digital module used solely with Honeywell Smartline™ 3000
transmitters.
'HV' modules have four Honeywell DE™ digital protocol ports dedicated to Honeywell SMV
3000 transmitters. Two analog outputs are provided.
'SV' modules provide two RS-485 channels to be used with Rosemount 3095FB multivariable
transmitters, Micro Motion RFT 9739, Daniel, Instromet, FMC Kongsberg, Caldon and Krohne
ultrasonic devices. There are six analog outputs provided.
To determine the total number of combo modules (Types 'A' + 'B' + 'E' + 'E/D' + 'H' + 'HV' +
'SV') required, the number of temperatures, pressures, densitometers, gravitometers,
differential pressures, turbine/PD meter pick-offs that will have interfacing connections
should be added. Remember to provide for sufficient space for physical I/O. Round the
number up to the nearest increment of four and divide that number by four. Please consult
Omni when 'HV' or 'SV' modules are required.
The Omni 3000 is limited to one dual serial I/O module. The Omni 6000 can accept up to
three serial I/O modules. The first port can be configured for a printer or Modbus™. All
sixports are Modbus-compatible slaves. Port #2 can be used as a Modbus master for
redundant flow computer applications and communicating with slave devices. The SE Module
provides two communication channels. Channel one is an RS-232/RS-485 serial channel and
channel two is a 10BaseT Ethernet channel. The computer includes an AC/DC power supply
suitable for use with 24VDC, 120VAC and 240VAC. When AC powered, the Omni 3000
provides a maximum of 650mA at 24VDC for powering the transducer loops. The Omni 6000
provides a maximum of 500mA at 24VDC.
Power
The computer includes an AC/DC power supply suitable for use with 24VDC, 120VAC,and
240VAC. When AC powered. the Omni 3000 provides a maximum of 650mA at 24VDC for
powering the transducer loops. The Omni 6000 provides a maximum of 500mA at 24VDC.
Firmware Revision
Firmware is available either in US or metric customary measurement units for liquid or gas
applications.