From

Company: Date:
Address: Phone:
Fax:
End-User: *
Contact: Final Destination: *
* Required

Rev. 20-Liquid: Turbine/PD/Mass/Ultrasoinc (US) Rev. 24-Liquid: Turbine/PD/Mass/Ultrasonic (Metric)

Rev. 21-Liquid: Orifice Meter (US) Rev. 25-Liquid: Orifice Meter (Metric Units)

Rev. 22-Liquid: Turbine/PD Meter with MF Curve (US) Rev. 26-Liquid: Turbine/PD Meter with MF Curve (Metric)

Rev. 23-Gas: Orifice/Turbine/Ultrasonic Meter (US) Rev. 27-Gas: Orifice/Turbine/Ultrasonic Meter (Metric)

(select one)–
Oils: Crude Oil Refined Products LPGs Propylene Ethylene NGLs E-P Mix
Gases: Nat. Gas Ethylene CO2 Steam N2 O2 H2 Ar2
Other:

(select one) (select one)


110-120VAC & 18-24VDC 220-240VAC & 18-24VDC English French Spanish Russian

*Note: this is the keypad only - Menus will be in English.

(Also see web site www.omniflow.com/products/mountion options)

Standard Panel Standard Panel Mount With Separate 3 Piece Assembly; Separate Keypad, card chassis (18 in
Back Panel & 5ft* Extended Cables cable between)and Back Panel with 5 ft* Extended Cables
*Standard cable length 5ft. Extended cables are optionally available in 10ft lengths.

(Only check box if you require Omni to mount the flow computer in an enclosure)

NEMA 4 (Carbon Steel) NEMA 4X (Stainless Steel )

Page 1 of 2
Meter Meter Meter Meter Common/
Run #1 Run #2 Run #3 Run #4 Station
Flow Meter*
select: Turbine (T), PD Meter (PD), Pulse Fidelity (PF), Ultrasonic
(USM)#, Diff. Pres. (DP) State if 1 or 2 DP transmitters per meter run)
Coriolis Mass
select: Yes (Y) or No (N)
Temperature
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD)
Pressure
select: 4-20mA (mA) or 1-5Volts (V) or Digital (D)
Gravity
select: 4-20mA (mA) or 1-5Volts (V) or Frequency (F)
Density
select: 4-20mA (mA) or 1-5Volts (V) or Frequency (F)
Density Temperature
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD)
Additional Analog Inputs (BS&W, CO2, N2, O2 etc.)
select: 4-20mA (mA) or 1-5Volts (V)
Gas Analyzer
select: 4-20mA (mA) or RS232 (RS)
Smart Multi-Variable
select: Rosemount (SV) (modbus only) or Honeywell (HV)
*Note: Combination of Turbine and Differential Pressure inputs is only available on Rev. 23 and 27.
#Note: Please state if ultrasonic meter output is serial data, pulse or both.

Plenum Pressure (Brooks Only.) Digital I/O Points Required


select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD) Maximum 24
Dual chronometry Proving ? 4-20 mA outputs Required
Select: Yes (Y) or No (N) (Maximum 12)
Inlet Temperature Serial Ports Required
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD) (Maximum 6 (6000) and 2 (3000)
Outlet Temperature Ethernet Port Required
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD) (Maximum 2 (6000) and 1 (3000)
Inlet Pressure
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD)
Outlet Pressure
select: 4-20mA (mA) or 1-5Volts (V) or RTD 4-Wire (RTD)
Prover Density
select: Analog (A) or Frequency (F)

Model Number: Qty:

Flow Meter Brand:

Comments:

Omni Flow Computers, Inc. 12620 W. Airport Blvd., Suite 100 Sugar Land, Texas 77478 USA
Tel: 281-240-6161 Fax: 281-240-6162 Website: http:// www.omniflow.com E-mail: sales@omniflow.com

Page 2 of 2
Submit Form Reset
Omni Flow Computers, Flow Meter, Data Acquisition, Flow Computer

About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us

Home| Sitemap | Make Enquiry | Employment | Search

PRODUCTS & SERVICES

OMNI has gained a worldwide reputation for providing superior product quality and
customer services in flow measurement. OMNI instruments integrate easily into
your metering, flow and valve control
and system communication needs.

Quality components and reliable,


optimized firmware and software
provide high performance for custody
transfer accuracy.

Click here for the Omni 3000/6000


OMNI has the largest installed base of multi-tasking, panel-mount 32-bit multi-run
Flow Computer Application
flow computers for the custody transfer measurement of hydrocarbon liquids and
Worksheet
gases. Worldwide in over 70 countries, OMNI flow computers are connected to
approximately 25,000 turbine, mass and ultrasonic flow meters and related
transducers in single and multi-run configurations. SUPPORT

OMNI’s continued growth depends on


responsive technical support and
customer education.

Click here to download manuals and


brochures, search the knowledge base,
or use our library of industry related
links.

NEWS & EVENTS

Relevant industry news and links to


industry conferences, expositions and
training schools. Click here.

Check out events to see if we’ll be in


your area or contact us to see our
worldwide representatives list.

Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting

©2003 Omni Flow Computers, Inc. All rights reserved

http://www.omniflow.com/ [10/02/2008 09:20:12]


Products and Services

About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us

Home | Sitemap | Make Enquiry | Search

Products and Services

Hardware Solutions
OMNI Flow Computers has acquired a leading role in flow measurement technology with its
OMNI 3000 and OMNI 6000 product lines of flow computers, software, controllers and RTUs.
Software Solutions
Instruments of Choice
Major industry users specify OMNIs as their flow Training Solutions
computers of choice on many upgrade and new
projects. They recognize the versatile, built-in
functions of these instruments for measurement
and control - indispensable for pipeline, terminal,
petrochemical and process applications.

Standard software for liquids and


gases
Virtually any fluid or gas, from crude oil, refined
products, LPGs, NGLs, propylene and ethylene to natural gas, carbon dioxide and other
industrial gases can be measured without the expense of custom software support typical of
other computer and RTU manufacturers.

Putting it All Together


OMNI took a systems approach to its product designs. That resulted in an optimum assembly
time for putting together the elements - components, boards, standard software. It shortens
the build cycle and gets the product to the customer on schedule.

I/O boards are quality tested and temperature-trimmed to optimize analog resolution, and
burned-in before shipment for field installation.

Standard Hardware to Match the Application


OMNI has the capability to match its standard products to the
customer's application needs. The non-restrictive I/O bus
design permits any combination of inputs and outputs to meet
most metering, flow and valve control and communication
requirements.

Higher Accuracy Technology


Plug-in I/O modules provide the customer with an assurance of
maximum product life by higher accuracy measurement
technologies such as meter pulse fidelity checking and
HoneywellTM digital transmitter interface modules.

Protecting the Customer's Investment


OMNI has worked hard to ensure that the benefits of new developments in measurement
standards and operations practice are passed on to its customers at minimal expense. OMNI
standard software eliminates field training time and enables customers to connect their
hardware to almost any field equipment in a real-time environment.

Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting

©2003 Omni Flow Computers, Inc. All rights reserved

http://www.omniflow.com/productsandservices/index.html [10/02/2008 09:20:36]


General Information of Omni Products

About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us

Home | Sitemap | Make Enquiry | Search

Products and Services

Hardware Solutions
General Information on the Omni
Omni 3000/6000 Overview
Omni has the capability to match its standard products to
the customer's application needs. The non-restrictive I/O SmartBus Overview
bus design permits any combination of inputs and outputs
to meet most metering, flow and valve control and Literature
communication requirements.
Software Solutions
Exceptional Reliability
From components to I/O boards to operator front-panel Training Solutions
interfaces, Omni combines reliable, high-performance
hardware with software that's optimized for custody
transfer accuracy measurement and control operations.
Optical isolation all but guarantees continual performance.
With a system inherently immune to electrical noise, you
get dependability without the maintenance headaches.
That's why Omni has a three-year warranty for its
products.

Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting

©2003 Omni Flow Computers, Inc. All rights reserved

http://www.omniflow.com/productsandservices/hardwaresolutions/index.html [10/02/2008 09:20:46]


Omni Flow Computers Features Index

About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us

Home | Sitemap | Make Enquiry | Search

Products and Services

Hardware Solutions
The Omni 3000 and Omni 6000 Flow Computers are reliable, easy to use, uniquely
versatile instruments. They are usually factory-programmed for single and multi-run Omni 3000/6000 Overview
configuration measuring crude oils, refined products, NGLs, LPGs, ethylene, propylene,
natural gas, and specialty gases such as O2, N2, H2,Ar, H2O, and CO2. The compact, rugged Product Details
design and operation incorporate many user-requested features that can reduce or eliminate
requirements for other ancillary control devices. Design Features

Hardware Matrix
Key Features
Model Guide
• 500 msec calculation cycle
• Photo-optical isolation of each I/O point Mounting Options
• Online Configurable SCADA data packet
• 32 bit processing with math co-processor Omni 3000/6000 Metrological
Approvals
• 4 line, alpha-numeric, backlit LCD display
• Communications to 38.4K Baud Application Worksheet
• Stored reports and data archiving
• 34 button, alpha-numeric keypad SmartBus Overview

Remote Meter Controller


Additional Features Metrological Approvals
• Gas & Liquid Metering Literature
• Turbine and Orifice Calculations
• Flow & valve control
• Multiple Protocols for Gas chromatograph Software Solutions
interface
• Point-to-point digital transmitter interface
• Up to 4 flow/pressure control loops Training Solutions
• User configuration displays and reports
• On-line configuration software
• User configurable control logic
• 4-20 mA or Rtd temperature compensation

Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting

©2003 Omni Flow Computers, Inc. All rights reserved

http://www.omniflow.com/productsandservices/hardwaresolutions/omni30006000/index.html [10/02/2008 09:20:59]


Omni Product Details

About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us

Home | Sitemap | Make Enquiry | Search

Products and Services

Hardware Solutions
Photo-optical Isolation of Each I/O Point
Omni 3000/6000 Overview
The isolation of circuitry via photo-optical devices from all field wiring prevents accidental
damage to the electronics, including that caused by static electricity. The isolation also Product Details
inhibits electrical noise from inducing measurement errors. All I/O is modular and plug-in for
easy field maintenance and replacement. Design Features

Hardware Matrix
32 Bit Processing with Math Co-Processor
Model Guide
A powerful 16/32 bit, CMOS microprocessor and
32 bit floating point math co-processor are used Mounting Options
for high-speed execution of both high-level and
assembler code instructions. They provide in Omni 3000/6000 Metrological
excess of 1 MTOPS. A hardware real-time clock is Approvals
also incorporated. Time-keeping continues even
when power is lost to the Omni, which Application Worksheet
automatically resets on power-up. Time and
duration of power failure is logged, and printed SmartBus Overview
when power is restored.
Remote Meter Controller
Up to 1 Mbyte of CMOS SRAM and 1 Mbyte of Metrological Approvals
CMOS EPROM are standard on the CPU module.
All SRAM is backed up by nickel-cadmium Literature
batteries.
Software Solutions
4 line, Alpha-numeric, back-lit LCD Display
The 4 line x 20 alpha-numeric character, back-lit Liquid Crystal Display is updated every 500 Training Solutions
ms and displays all messages and system variables in English language engineering units.
Four dual-color LEDs indicate various operating modes and alarms. Three nonresettable 6
digit electromechanical counters are included on the front panel and can be programmed to
count gross, net mass or energy units at any rate up to 10 counts per second.

34 Button, Alpha-numeric Keypad


Control of the flow computer is via the front-panel 34 button, imprinted alpha-numeric
character membrane keypad with tactile domes and audio feedback. Imprinted characters
are color coded to indicate operator and program functions, as well as primary and
secondary alpha-numeric functions.

The keypad provides the user with a unique on-line capability to configure measurement and
control data, perform diagnostic tasks and display operator information. Context-sensitive
help screens are provided as an additional aid.

Configuration, program and diagnostic data can be entered via the keypad or remotely by
serial hook-up into battery-backed up, CMOS SRAM memory. Security codes and an internal
mechanical switch ensure that configure/program functions can be disabled when required.

Communications to 38.4K Baud Supported


Multiple port high-speed serial communications up to 38.4K baud is provided for direct
interface with SCADA and process control mainframes. Software selectable baud rates also
allow for multi-drop RS232C communications with printers, PCs, and various brands of digital
transmitters.

Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting

©2003 Omni Flow Computers, Inc. All rights reserved

http://www.omniflow.com/productsandservices/hardwaresolutions/omni30006000/productdetails.html [10/02/2008 09:21:10]


Omni Model Guide

About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us

Home | Sitemap | Make Enquiry | Search

Products and Services

Hardware Solutions
Model Number
Omni 3000/6000 Overview
The Omni 3000 is designed to accept two combo modules, one 12-channel digital I/O module
and one dual-channel serial I/O module. The Omni 6000 can accept up to six combo Product Details
modules, two 12-channel digital I/O modules and two dual channel serial I/O modules. If the
number of combo modules required, including communication boards and spare I/O's, is Design Features
greater than the Omni 3000 limits, select an Omni 6000.
Hardware Matrix

Model Guide

Mounting Options

Omni 3000/6000 Metrological


Approvals

Application Worksheet
Remember to provide for sufficient spare I/O for your computer system. A
minimum I/O system is not a manufacturer-recommended practice in important SmartBus Overview
measurement applications.
Remote Meter Controller
Combo Modules Required Metrological Approvals

'A' modules provide four input channels, two selectable as analog only input channels. The Literature
third and fourth input channels are selectable analog or pulse. Two analog outputs are
available.
Software Solutions
'B' modules provide four input channels where the first three process inputs are identical to
the 'A' module and the fourth channel is fixed to provide a periodic time density pulse input.
Training Solutions
One analog output is provided. The number of 'B' type combo modules required are equal to
the number of digital pulse densitometers that are interfacing (see type 'E/D' below).

'E' modules provide two selectable analog inputs and either two single pulse inputs or one
dual pulse input, when pulse fidelity checking is required. One double chronometry detector
switch input and two analog outputs are also provided.

'E/D' modules provide four process inputs including two analogs and two periodic time
density pulse inputs on the third and fourth channels. Two analog outputs are provided.

'H' denotes a four input digital module used solely with Honeywell Smartline™ 3000
transmitters.

'HV' modules have four Honeywell DE™ digital protocol ports dedicated to Honeywell SMV
3000 transmitters. Two analog outputs are provided.

'SV' modules provide two RS-485 channels to be used with Rosemount 3095FB multivariable
transmitters, Micro Motion RFT 9739, Daniel, Instromet, FMC Kongsberg, Caldon and Krohne
ultrasonic devices. There are six analog outputs provided.

To determine the total number of combo modules (Types 'A' + 'B' + 'E' + 'E/D' + 'H' + 'HV' +
'SV') required, the number of temperatures, pressures, densitometers, gravitometers,
differential pressures, turbine/PD meter pick-offs that will have interfacing connections
should be added. Remember to provide for sufficient space for physical I/O. Round the
number up to the nearest increment of four and divide that number by four. Please consult
Omni when 'HV' or 'SV' modules are required.

Digital I/O Modules Required


'1D' (12 digital I/O) is always used when specifying an Omni 3000. An Omni 6000 can use
'2D'. To determine the number of digital I/O modules needed, the number of digital I/O
points required must be added for the total. These include, but are not limited to prover
detector inputs, sampler pulse outputs, control outputs, alarm outputs and control inputs.

Serial / Ethernet I/O Modules Required

http://www.omniflow.com/productsandservices/hardwaresolutions/omni30006000/modelguide.html (1 of 2) [10/02/2008 09:21:30]


Omni Model Guide

The Omni 3000 is limited to one dual serial I/O module. The Omni 6000 can accept up to
three serial I/O modules. The first port can be configured for a printer or Modbus™. All
sixports are Modbus-compatible slaves. Port #2 can be used as a Modbus master for
redundant flow computer applications and communicating with slave devices. The SE Module
provides two communication channels. Channel one is an RS-232/RS-485 serial channel and
channel two is a 10BaseT Ethernet channel. The computer includes an AC/DC power supply
suitable for use with 24VDC, 120VAC and 240VAC. When AC powered, the Omni 3000
provides a maximum of 650mA at 24VDC for powering the transducer loops. The Omni 6000
provides a maximum of 500mA at 24VDC.

Power
The computer includes an AC/DC power supply suitable for use with 24VDC, 120VAC,and
240VAC. When AC powered. the Omni 3000 provides a maximum of 650mA at 24VDC for
powering the transducer loops. The Omni 6000 provides a maximum of 500mA at 24VDC.

Power Requirements must be specified

Firmware Revision
Firmware is available either in US or metric customary measurement units for liquid or gas
applications.

Application firmware revision numbers must be specified.

Home | About Omni | Products and Services | Online Catalogue | Support | News and Events | Contact Us | GoTo Meeting

©2003 Omni Flow Computers, Inc. All rights reserved

http://www.omniflow.com/productsandservices/hardwaresolutions/omni30006000/modelguide.html (2 of 2) [10/02/2008 09:21:30]