Professional Documents
Culture Documents
Questions For Scaffolding GI 8.001
Questions For Scaffolding GI 8.001
1. Who fills in the scaffold field inspection checklist for a scaffold over 6 meters?
3. Who Should verify and sign the scaffold plan prior to submitting to the proponent?
a. Scaffold Erector
b. Scaffold inspector
c. Structural Engineer
d. Scaffold Supervisor
4. Which check list used for performing pre – use safety inspection?
a. Structural Engineer
b. ALPD
c. Proponent
d. CSD
Page 1 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
c. Scaffold over 38 meters
d. Scaffold supported by or hung from outrigger beams
7. All scaffold shall built in accordance with the work process/decision flowchart of which
publication?
a. SSH
b. CSM
c. GI 8.001
d. GI SSH ,CSM
a. Proponent
b. LPD
c. Scaffold Supervisor
d. Scaffold Inspector
10. Who shall confirm the adequacy of the existing structure to support the scaffold load
and ensure that all necessary precautions are taken?
a. Scaffold Erector
b. CSD
c. ALPD
d. Proponent
11. What does the yellow Scaffold tag Signifies on the scaffold?
Page 2 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
12. Prior to how many days, shall a scaffold plan of Special Scaffold be submitted to the
ALPD?
a. 2 weeks
b. 4 weeks
c. 3 weeks
d. 1 weeks
13. Who shall survey the job site prior to scaffold erection?
15. Who shall verify the scaffold plan for job functionality and access?
16. Who shall review if deviation from an accepted scaffold plan is required?
a. ALPD
b. Proponent
c. CSD
d. Supervisor
17. Under whom supervisor and direction shall scaffold be altered and dismantle?
a. Supervisor
Page 3 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
b. ALPD
c. CSD
d. Inspector
18. Scaffold craftsman shall wear PPE, including personal fall arrest system during erection,
alteration & dismantling in accordance to which publication?
a. SSH &CSM
b. GI
c. Manufactures Guideline
d. GI, CSM &SSH
a. LPD
b. Representative of Scaffold Erector
c. Representative of proponent
d. CSD
a. anyone
b. Scaffold Supervisor & inspector
c. Proponent
d. Health & safety department
a. The Proponent files it for use as a model for similar jobs in the future
b. The scaffold erector files it for use as a model for similar jobs in the future
c. Returned to the scaffold erector
d. Returned to the scaffold Supervisor
27. Who fills in the scaffold field inspection checklist for a scaffold up to 6 meters?
a. Proponent
b. Scaffold inspector
c. Scaffold Supervisor
d. Scaffold Erector
a. Proponent
Page 5 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
b. Scaffold Erector
c. LPD
d. CSD
29. Who shall sing a green or yellow tag for scaffold up to 6 meters?
30. Who shall sign a green or yellow tag for a scaffold over 6 meters?
31. Who shall enter the date of next inspection on green or yellow Scaffold tag over 6
meters?
a. Scaffold erector
b. Scaffold supervisor
c. Scaffold inspector
d. Scaffold Supervisor & inspector
32. Who shall securely affix a green or yellow tag on scaffold tag over 6 meters?
a. Scaffold Inspector
b. Scaffold erector
c. Scaffold supervisor
d. Scaffold Supervisor and inspector
a. Scaffold craftsmen under the supervisor of the supervisor of the scaffold erector
b. Scaffold craftsman under the supervisor of the proponent
c. Scaffold Craftsman under the supervisor of any supervisor
d. Scaffold craftsman under the supervisor of LPD
Page 6 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
34. Who shall notify the scaffold erector that the scaffold is ready for dismantle?
a. Proponent
b. LPD
c. Supervisor
d. inspector
36. Who shall ensure that the scaffold craftsman is wearing PPE?
a. Safety officer
b. Supervisor
c. Proponent
d. Inspector
37. Which of these would be a major hazard affecting the operation of scaffold?
a. work on roof
b. Overhead power line
c. Excavation
d. work over water
39. When should a red (DO NOT USE) tag be clearly visible on a scaffold structure?
Page 7 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
b. Until inspection not done and appropriate tagged
c. when scaffold is unsafe
d. All of above
40. When a scaffold structure of 8 meters in height has been altered, which authorities must
insect and re – tag it?
41. Scaffold supervisor can sign (tags) on their own on scaffold up to height of?
a. Any height
b. Up to 6 meters
c. Above 6 meters
d. All of above
42. Scaffold inspector must can sign (tags) on the following types of scaffold?
a. or b,c,d
b. Scaffold up to 6 meters special scaffolds requiring a plan
c. Scaffold over 6 meters special scaffold requiring a plan
d. Scaffold over 38 meters special scaffold requiring plan
43. The specialized scaffold erector should ensure that their scaffold plan is complete in
accordance with which publication?
44. Who reviews every scaffold plan for completeness, functionality, access and any
clearance requirements prior to submitting it to the loss prevention department?
Page 8 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
c. CSD
d. Safety Supervisor
46. A medium-duty scaffold with two working levels can have a maximum height of:
a. 78 feet or 24 meters
b. 91 feet or 28 meters
c. 125 feet or 38 meters
d. None is given
47. Safe landings shall be provided at the top of all ladders and at least _______________ of
ladder height.
48. For insulated power lines, what is the minimum safe clearance between power lines and
scaffold for 300 volts to 50 kV?
49. For insulated power lines, what is the minimum safe clearance between power lines and
scaffold for less than 60 kV?
Page 9 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
50. What is the minimum distance the gin wheel shall be mounted on a cantilever tube
projecting outward from the scaffold?
a. 550 mm
b. 850 mm
c. 450 mm
d. 750 mm
52. What bracing is important to prevent excessive sway and necessary in both transverse
and longitudinal directions of all system and tube and coupler scaffolds?
54. System scaffold components shall not be used to construct what type of scaffolds?
55. Bearer (transoms), including board bearers (intermediate transoms) shall extend at least
_______________ beyond the runner centerline.
Page 10 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
a. 550 mm
b. 100 mm
c. 450 mm
d. 200 mm
56. What scaffold tool is required to tighten scaffold couplers to the torque between 40 kg-m
to 80 kg-m?
a. spanner
b. cheater bars
c. long handled wrenches
d. none of the above
57. What is the maximum scaffold height required for light-duty tube and coupler scaffold
with maximum 3 working levels?
58. What is the maximum scaffold height required for medium-duty tube and coupler
scaffold with maximum 1 working level?
59. Mobile and tower scaffold shall be horizontally and vertically braced in what directions?
a. both directions
b. one direction only
c. no direction required
d. upward direction
60. What is the maximum post spacing required in both directions for light-duty tube and
coupler, mobile and tower scaffolds that are 1 bay long and 1 bay wide and constructed
with steel tubing that is NOT manufactured and embossed.
Page 11 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
a. 6 meters (20 feet)
b. 9 meters (30 feet)
c. 3 meters (10 feet)
d. 1.7 meters (5.5 feet)
61. What is the maximum post spacing required in both directions for light-duty tube and
coupler, mobile and tower scaffolds that 1 bay long and 1 bay wide and constructed with
steel tubing that is manufactured and embossed?
a. base plate
b. screw jacks
c. sill (sole board or sole plate)
d. none is given
63. What is the required diameter of steel casters for mobile scaffold rated for light-duty?
a. 120 mm
b. 100 mm
c. 170 mm
d. 200 mm
64. What is the required diameter of steel casters for mobile scaffold rated for medium-
duty?
a. 120 mm
b. 100 mm
c. 170 mm
d. 200 mm
65. What shall be used to fit all casters to prevent movement while the mobile scaffold is
being used?
a. screw jacks
Page 12 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
b. positive wheel lock
c. negative wheel lock
d. none is given
66. Which of the following is not permitted for mobile or tower scaffold?
69. What is the required load in order fabricated tubular frame scaffold can be used?
Page 13 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
71. What is the maximum height of fabricated tubular frame scaffold?
a. medium-duty
b. light-duty
c. special-duty
d. heavy-duty
73. Bracket, bracket straps and other associated structural members shall be free from
_______________.
a. detrimental corrosion
b. damage
c. defects
d. a, b, c
a. diagonally
b. vertically
c. horizontally
d. none is given
75. A guardrail system shall be provided on the inside platform edge when the gap between
the platform and tank is _______________.
77. When should the guardrail support uprights be constructed above the walking surface?
a. the top rail is 0.95 m (38 inches), not more than 1.15 m (45 inches)
b. the top rail is 1.90 m (76 inches), not more than 2.30 m (90 inches)
c. the top rail is 2.85 m (114 inches), not more than 3.45 m (135 inches)
d. none of the above
78. What is the vertical distance from the top edge of toeboard to the level of the
walking/working surface?
a. 100 mm (4 inches)
b. 200 mm (8 inches)
c. 300 mm (12 inches)
d. 400 mm (16 inches)
a. 50 mm (2 inches)
b. 25 mm (1 inch)
c. 75 mm (3 inches)
d. 100 mm (4 inches)
80. How many kilograms a solid toeboards can be capable of withstanding a load in any
downward or horizontal direction?
Page 15 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
d. 3 meters (10 feet)
82. What is the minimum diameter of wire rope that horizontal and vertical lifelines be
made of?
a. 50 mm (2 inches)
b. 25 mm (1 inch)
c. 75 mm (3 inches)
d. 10 mm (3/8 inch)
83. What degrees that temporary stairways be installed above the horizontal?
84. What is the minimum clearance shall be provided between the handrail and wall or
other object?
a. 50 mm (2 inches)
b. 25 mm (1 inch)
c. 80 mm (3 inches)
d. 10 mm (3/8 inch)
85. What is the required slope that straight ladders and extension ladders shall be placed?
a. 3:1
b. 4:1
c. 2:3
d. 1:5
86. What is the minimum clear perpendicular distance of ladders from the rungs to the
nearest projecting object on the climbing side?
Page 16 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
87. How many person/s shall be required on a single-run ladder at a time?
a. two persons
b. only one person
c. three persons
d. four persons
88. If the length of the rung is 500 mm (20 inches) or less, what is the required thickness?
a. 50 mm (2 inches)
b. 20 mm (0.78 inch)
c. 80 mm (3 inches)
d. 10 mm (3/8 inch)
89. Why scaffold components made of dissimilar metals shall not be used together?
90. Guardrail systems shall be able to withstand, without failure, a force of at least
_______________.
91. How long a guardrail system at hoisting areas shall be erected on each side of the access
point through which material is hoisted?
92. At what height that a person could fall shall be protected from falling by a fall protection
system?
Page 17 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
a. 3.6 meters (12 feet)
b. 1.8 meters (6 feet)
c. 2 meters (6.5 feet)
d. 3 meters (10 feet)
a. 100 mm (4 inches)
b. 200 mm (8 inches)
c. 300 mm (12 inches)
d. 400 mm (16 inches)
97. For scaffolds over 38 meters (125 feet), what type of scaffold is preferred to erect?
Page 18 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
d. none of the above
98. What is the minimum number of clips to be installed at the load end and at the
attachment end of each wire rope?
a. 4
b. 5
c. 3
d. 6
a. 10 rope diameters
b. 7 rope diameters
c. 8 rope diameters
d. 6 rope diameters
ANSWERS
Page 19 of 20
QUESTIONAIRE FOR SCAFFOLDERS:
a b c d a b c d a b c d a b c d a b c d
1 21 41 61 81
2 22 42 62 82
3 23 43 63 83
4 24 44 64 84
5 25 45 65 85
6 26 46 66 86
7 27 47 67 87
8 28 48 68 88
9 29 49 69 89
10 30 50 70 90
11 31 51 71 91
12 32 52 72 92
13 33 53 73 93
14 34 54 74 94
15 35 55 75 95
16 36 56 76 96
17 37 57 77 97
18 38 58 78 98
19 39 59 79 99
20 40 60 80 100
Page 20 of 20