Quality Control Services Testing Lab
Quality Control Services Testing Lab
Quality Control Services Testing Lab
Wt. of Wt. of
Sieve Material Retained Cumulative %
Container Container+ % Retained Remarks
Opening (gm) Retained
(gm) Sand (gm)
4.75mm 458 465.0 7.0 0.70 0.70
2.36mm 518 535.4 17.4 1.74 2.44
1.18mm 487 570.0 83.0 8.31 10.76
600µm 405 920.8 515.8 51.65 62.41
300µm 388 678.0 290.0 29.04 91.45 Clay Content
150µm 350 423.2 73.2 7.33 98.78 0.40%
75µm 350 358.2 8.2 0.82 99.60
Pan 421 425.0 4.0 0.40 99.18
Total = 999
FM = 2.67
Name : Engr. Md. Thouhid Rahman Name : Engr. Md. Mostafizur Rahman
Designation : Lab Engineer Designation : Sr. Manager
Note: Sample have been testedas it was supplied in CMTL. CMTL does not have any responsibility to the representative standard of the
sample required to be tested. It is recommanded thatsample are sent in secure & sealed cover / packet / container with signature of the
RCC Ref no : RCC/Jan30/19 Customer Ref no :
Name of Customer: Date of Sample received :
Address: Condition on received:
Project:
Wt. of Wt. of
Sieve Material Retained
Container Container+ % Retained
Opening (gm)
(gm) Sand (gm)
4.75mm 458 468 4.8 0.97
2.36mm 518 578 7.0 1.42
1.18mm 487 522 39.0 7.89
600µm 405 633 292.4 59.19
300µm 388 497 113.8 23.04
150µm 350 393 33.2 6.72
200µm 350 353 2.8 0.57
Pan 421 436 1.0 0.20
Total = 494
FM =
Counter Signed by
Note: Sample have been testedas it was supplied in CMTL. CMTL does not have any responsibility to the representative stand
sample required to be tested. It is recommanded thatsample are sent in secure & sealed cover / packet / container with signat
competent authority.
Testing Lab
D
hali
8 02Dhaka – 1206
8831751
rcclab.net
STM C 33
Cumulative %
Remarks
Retained
0.97
2.39 Clay Content = 0.20%
10.28
69.47
92.51 Clay Content
99.23 0.20%
99.80
99.43
2.75