Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

PROJECT Title JOB: 1518.

01
Locatio PILE DESIGN BY: TYC
(1). Pile Shear capacity

Strength Requirement
1926.7.4.2

Axial Compression(1911.3.1.2)
Vc = 0.166(1+0.073Nu/Ag)fc' 0.5Ag
and Vc not greater than 0.166fc' 0.5Ag

Allowable concrete stress, fcu 25 N/mm2


Allowable concrete stress, fc' 21.25 N/mm2
Concrete pile 2000
Concrete area, Ag( 80% of gross area) 2513274 mm2
Vc not greater than 0.166fc' 0.5Ag 1923 kN
Strength reduction factor, f 0.7 cl: 1909.3.2.2

(a). Compression on Piles (w/o shear link)

Pile Type Pile Size Reinft Pile Working Load Ultimate Load Ag Vc' Allowable shear Nominal shear stre Working capacity
mm (kN) Nu (kN) (kN) Vc (kN) cl:1911.5.5 fVn (kN) cl:1911.1.1 Vs (kN)

P2000 2000 18700 28049.9344 2513274 1923 962 673 437

(b).Compression on Piles (w/ shear link)

Allowable concrete stress, fcu 25 N/mm2 Axial compression(1911.5.6.2)


Vs =3.14AbfyhD' / 2s
Allowable concrete stress, fc' 21.25 N/mm2
Concrete pile 2000
Concrete area, Ag ( 80% of gross area) 2513274 mm2
Vc not greater than 0.166fc' 0.5Ag 1923 kN
Axial Compression(1911.3.1.2)
Specified yield strength, fy 390 N/mm2 Vc = 0.166(1+0.073Nu/Ag)fc' 0.5Ag
Shear Link provided sizes 12 mm and Vc not greater than 0.166fc' 0.5Ag

Spacing, s 150 mm
Avprov 113 mm2
Min. Shear requirement, Av =0.34bws/fy 123 mm2
Strength reduction factor, f 0.7 cl: 1909.3.2.2

Pile Type Pile Size Reinft Pile Working Load Ultimate Load shear strength shear strength Nominal shear strength Working capacity
mm spacing (kN) N (N) Vc (kN) cl:1911.5.5 Vs (kN) cl:1911.5.6 fVn (kN) cl:1911.1.1 Vs (kN)

P2000 2000 100 18700 28049.9344 962 520 1037 673

In conclusion, the moment capacities for piles P1 to P7 & P9 are greater than moment induced (233kNm).

(c).Tension on Piles
Allowable concrete stress, fc' (C60) 25 N/mm2 Axial Tension(1911.5.6.2) Axial Tension(1911.3.2.3)
Vs =3.14AbfyhD' / 2s Vc = 0.166(1+0.29N/Ag)fc' 0.5Ag
Concrete area, Ag ( 80% of gross area) 2513274 mm2
and Vc not greater than 0.09fc' 0.5Ag
Vc not greater than 0.166fc' 0.5Ag 2086 kN
S h e a r S t re n g t h , k N

Concrete area, Ag ( 80% of gross area) 2513274 mm2


Vc not greater than 0.166fc' 0.5Ag 2086 kN
Specified yield strength, fy 235 N/mm2 P2A and P5A fVn

Shear Link provided sizes 12 mm 1600


1400
Spacing, s 150 mm 1200
Avprov 113 mm2 1000
800
Min. Shear requirement, Av =0.34bws/fy 74 mm2 600
400
Strength reduction factor, f 0.7 200
0
cl: 1909.3.2.2 -3000 -2500 -2000 -1500 -1000 -500 0
Ultimate Tension, kN

Pile Type Pile Size Reinft Comp. Working LoadTension ULT Load shear strength shear strength Nominal shear strength Working capacity
mm (kN) N (kN) Vc (kN) cl:1911.5.5 Vs (kN) cl:1911.5.6 fVn (kN) cl:1911.1.1 Vs (kN)
P2000 2000 32T25 0 -500 1966 209 1522 988
(0.5%) -1000 1845 209 1438 934
-1500 1725 209 1354 879
-2000 1605 209 1269 824
-2500 1484 209 1185 770
-3000 1364 209 1101 715
P2000 2000 16T25 0 -500 1966 209 1522 988
(0.25%) -1000 1845 209 1438 934
-1500 1725 209 1354 879
-2000 1605 209 1269 824
-2500 1484 209 1185 770
-3000 1364 209 1101 715
In conclusion, the moment capacities for piles are greater than moment induced (233kNm).

(2).Pile Confinement Reinforcement

ACI-99 Section 21.8.4.4 - requires min. transverse reinforcement at certain location in the bored piles.
ACI-99 Section 21.4.4 -provide these equations.
rs = 0.12 . f'c/fyh Eqn (21-2) 1)rs =0.12fc'/fyh
Eqn (21.3) - need not comply due to provision in Section 21.4.4.1 Item (d) 2)s - links spacing c/c
Eqn (10-5) - need not comply due to provision in Section 21.4.4.1 Item (d) 3)hc - enclosed area by link
4) As = rs(fc'/fyh)Vconc/(2phc/2)
Eqn (21.4) - used for rectangular hoop, not to be use for spiral or circular hoop reinf.

Pile type Working Equivalent fc' fyh rs s hc Vconc Length of link Asreq Bar
load (N/mm2) (N/mm2) mm mm mm3 (mm) (mm2) provided
P1 2000 18700 6.0 390 0.0018 100 1850 268802521.42 5812 85 T12

Note : The confinement zone shall be limited 5 diameter from pile cut off level. The remaining circular links will be T10-300.
Pile Shear capacity
Alternative Design Method
1926.7.4.2
Axial Compression(1926.7.4.3)
vc = 0.09(1+0.004N/Ag)fc' 0.5 Axial Tension(1926.7.4.5)
and vc not greater than 0.09fc' 0.5 vc = 0.09(1+0.0006N/Ag)fc' 0.5
and vc not greater than 0.09fc' 0.5

Allowable concrete stress, fc' (C60) 45 N/mm2


vc not greater than 0.09fc' 0.5 0.604 N/mm2
Concrete area, Ag ( 80% of gross area) 508938 mm2

Compression on Piles

Pile Type Pile Size Reinft Pile Working Load Service Load Shear Stress
mm (kN) N (kN) vc (N/mm2)
P1 900 8T25 3500 3500 0.604
P2 900 8T25 4500 4500 0.604
P3 900 8T25 5500 5500 0.604
P4 900 8T25 6500 6500 0.604
P5 900 8T25 7500 7500 0.604
P6 900 8T25 8500 8500 0.604
P7 900 8T25 9500 9500 0.604
P9 900 15T32 4500 4500 0.604

In conclusion, the moment capacities for piles P1 to P7 & P9 are greater than
moment induced (233kNm).
5)
)fc' 0.5
0.09fc' 0.5

Allowable shear
Vc (kN) cl:1926.7.5.4.3
154
154
154
154
154
154
154
154
Pile Shear capacity
Alternative Design Method
1926.7.4.2
Axial Compression(1926.7.4.3)
vc = 0.09(1+0.004N/Ag)fc' 0.5 Axial Tension(1926.7.4.5)
and vc not greater than 0.09fc' 0.5 vc = 0.09(1+0.0006N/Ag)fc' 0.5
and vc not greater than 0.09fc' 0.5

Compression on Piles

Pile Type Pile Size Reinft Pile Working Load Ultimate Load Moment Capacity
mm (kN) Np (kN) Mp (kNm)
P1 900 8T25 3500 5250 1622
P2 900 8T25 4500 6750 1661
P3 900 8T25 5500 8250 1663
P4 900 8T25 6500 9750 1596
P5 900 8T25 7500 11250 1451
P6 900 8T25 8500 12750 1226
P7 900 8T25 9500 14250 925
P9 900 15T32 4500 6750 2038

In conclusion, the moment capacities for piles P1 to P7 & P9 are greater than
moment induced (233kNm).