Power Solutions for

Telecommunications
Flexible and modular telecom solutions for
Europe, Middle East and Africa

www.deltapowersolutions.com
2 3

About Delta Group Contents


Delta Group, founded in 1971, is the world’s top provider has built environmentally-friendly green buildings around the
of power management and thermal management solutions.
Facing the issue of climate change, Delta Group pursues
globe since 2004 for its factories and offices.
Systems: Indoor systems 6 Systems
CellD
the mission “To provide innovative, clean and energy- Delta Group has received many global awards and
efficient solutions for a better tomorrow.” As an energy- noteworthy recognition. In 2011 Delta was named to two of Ready to use systems
Systems: Indoor systems 11
saving solutions provider, Delta’s business scope covers the prestigious Dow Jones Sustainability Indexes: the DJSI
CabD Modular
power electronics, energy management and smart green World Index and the DJSI Asia/Pacific Index. Delta was
life. also recognized as a SAM Gold Class company in the 2012 Systems: Outdoor systems Flexible configurations
Sustainability Yearbook of Sustainable Asset Management OutD 13
Delta has sales offices worldwide and manufacturing plants (SAM).
in Taiwan, China, USA, Thailand, Japan, Mexico, India, Brazil Solutions: Renewable hybrid 15
and Europe. Committed to environmental protection, Delta RenE

Thermal Management 17

Smarter. Greener. Together. Intelligence:


System & Site Controller 18
Intelligence

Delta strives continuously to provide new, innovative


solutions for telecommunications that enable sustainable
Components:
Rectifiers 20 Components
development. Through our wide partner network, we are
able to offer these solutions everywhere in EMEA, even in
the most remote locations. The following outlines Delta’s
customer promise; our smart solutions boost your business,
energy-efficient power solutions reduce carbon footprint and
Services 22 Services
energy costs and Delta aims for long-lasting partnerships.
4 5

Delta Group: Fast Facts Delta EMEA:


Assembly, Testing, Service & Logistics center
Slovakia

7000+ 23 16 310 All Delta products delivered in the EMEA region are
assembled, tested and serviced from our assembly and
R&D engineers R&D labs manufacturing patents service center in Slovakia.
worldwide plants
Having a local hub within Europe assures full compliance
with all European quality requirements, quick assembly,
excellent service and shorter delivery times.

At Delta, we commit to quality. We trust our center in Slovakia


is an essential asset, which allows us to deliver top quality
products and first class service to our customers in the Dubnica nad Vahom, Slovakia
EMEA region.

global reach local strength

Delta Slovakia: plant details

18000m2 680 4000


production space local employees systems monthly

Certifications:
ISO 9001
ISO 14001
CSH OHSAS 18000

US$ Millions
0.04 4,846 6,609 7,081 7,101 7,180

33.4%
1971

2009

2010

2011

2012

2013

CAGR since 1971


Credit: p. 3-4 - the graphic features creatives designed by Freepik (www.freepik.com) and Flaticon (www.flaticon.com),
licensed under Creative Commons BY 3.0
6 7

Indoor systems: CellD Technical Specifications


CellD
Efficiency
95.2% 96.4% 97.2% CellD 40 CellD 100 CellD 125

General DPS 850B-48-3 DPS 850B-48-6 DPS 2900B-48-3 DPS 2900B-48-3


40A 2.55kW
DPS 850B-48-3

The CellD product family is based on DC power systems. 5.1kW


DPS 850B-48-6
They are modular and can be configured with additional 100A
components to meet any requirement. CellD systems are 8.7kW
DPS 2900B-48-3
the most compact on the market and offer extremely high Rectifier module DPR 850B-48 (max. 3 pcs.) DPR 850B-48 (max. 6 pcs.) DPR 2900B-48 (max. 3 pcs.) DPR 2900B-48 (max. 3 pcs.)

Installed power
power density. 125A 8.7kW
DPS 2900B-48-3
Efficiency 95.2% 95.2% 96.4% or 97,2% 96.2% or 97,2%
14.5kW
CellD units can be installed alongside other equipment, in DPS 2900B-48-5 19IN-5U
Install power (max. 2.55 kW 5.1 kW 8.7 kW 8.7 kW
an existing rack for example. They work seamlessly and at 17.4kW
config.)
DPS 2900B-48-6 19IN-6U
optimal efficiency up to more then 97% with Delta’s EnergE 300A
Input protection 25 A gL/gG fuse 3 x 10 A (3L+N+PE) 3 x 20 A (3L+N+PE) 3 x 20 A (3L+N+PE)
(recom.)
rectifiers and advanced controllers. This configuration 8.7kW
DPS 2900B-48-3 21IN-4U Dimensions H x W x D 43.6 (1U) x 444 (19’) x 280 mm 86.8 (2U) x 444 (19’) x 295 mm 86.8 (2U) x 444 (19’) x 323 mm 133.5 (3U) x 481.5 (19’) x 329 mm
ensures reliable system operation, generates savings in
Weight 4.1 kg 7.0 kg 7.0 kg 15 kg
OPEX and CO2, and maximizes battery lifetime. 17.4kW
DPS 2900B-48-6 21IN-5U AC input

AC configuration L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE or


34.8kW DPS 2900B-48-12 19IN- 3x (L+N+PE) or
9U L+N+PE
600A
Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS
20kW DPS 4000B-48-5 Frequency range 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz
19IN-7U
Mains connection Screw terminals Screw terminals Screw terminals Screw terminals

DC output

Max. output current / 40 A / 2.55 kW 100 A / 5.1 kW 100 A / 8.7 kW 125 A / 8.7 kW
max. installed power

Load breakers 6x(2-30 A) or 2 x (6-50A) 12 x (2-30 A) or 4 x (6-50A) 12 x (2-30 A) or 4 x (6-50A) 11 x MCB (2 – 63 A)

Battery breakers 2 x MHCB 50 A 2 x 100 A 2 x 100 A 2x MCB (80 – 125 A)

LVD (battery) Yes Yes Yes Yes

PLD (not critical loads) No Optional Optional Optional

Output protection Inbuilt fuses (both poles)


Over-heating protection

Critical / non critical N/A 6 / 6 or 2 / 2 6 / 6 or 2 / 2 5/6


loads configuration

Control / monitoring

Controller ORION; PSC 3

Local interface Display, keypad, LEDs


Main features Applications Remote monitoring Alarm relays, modem option, LAN, SNMP protocol

Others
• Wide DC power range – systems available from 40A up to • Wireless applications, network
600A base stations, applications, Operating temperature -45 - +65 °C -45 - +65 °C -45 - +65 °C -45 - +65 °C

• Extremely wide input AC voltage range – for all AC networks broadband services Humidity (relative) 95% max, non cond. 95% max, non cond. 95% max, non cond. 95% max, non cond.
in any location (80 … 300 Vac). Also for applications where • Transmission
Environment standard ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3
only a low quality AC grid is available • Modular UPS configurations
• Wide operating temperatures (-45 °C… +65 °C) Safety standard IEC 60950 IEC 60950 IEC 60950 IEC 60950
• Indoor and outdoor containers
• Modular structure and configuration adjusted to customer • Telecom, wireless, datacom EMC standard EN 300 386 EN 300 386 EN 300 386 EN 300 386
requirements
• Containers/shelters Ordering
• Highest efficiency – CellD systems use high-efficiency
System 3799321900 3799361100 3799361100 3791605600
EnergE rectifiers
• 19’’ platform – universal 19” rack mounted modules can be Rectifier TPS1010004B-PML-M TPS1010004B-PML-M ESR-48/56B F-S or ESR-48/56D ESR-48/56B F-S or ESR-48/56D
installed in different 19” structures and cabinets. Efficiency is 95.0~95.9% A-M A-M
• Advanced monitoring – state-of-the-art controllers ORION,
PSC 3; 6 alarm relays, modems, WEB Interface, SNMP Efficiency is 96.0~96.9%
protocol Efficiency is 97.0~97.9%
• Hot plug modules and components Pantone 2665 C
8 9

CellD Technical Specifications CellD Technical Specifications


CellD 600
CellD 300
General DPS 2900B-48-12 19IN-9U DPS 4000B-48-5 19IN-7U

General DPS 2900B-48-5 19IN-5U DPS 2900B-48-6 19IN-6U DPS 2900B-48-3 21IN-4U DPS 2900B-48-6 21IN-5U

Rectifier module DPR 2900B-48 (max. 12 pcs.) DPR 4000B-48 (max. 5 pcs.)
Rectifier module DPR 2900B-48 (max. 5 pcs.) DPR 2900B-48 (max. 6 pcs.) DPR 2900B-48 (max. 3 pcs.) DPR 2900B-48 (max. 6 pcs.) Efficiency 96.4% or 97,2% 95.2%
Efficiency 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% Install power (max. 34.8 kW 20 kW
config.)
Install power (max. 14.5 kW 17.4 kW 8.7 kW2 17.4 kW
config.) Input protection 2 x (3 x 40 A) 3 x 50 A
(recom.)
Input protection 3 x 40 A (3L+N+PE) 3 x 40 A (3L+N+PE) 3 x 20 A (3L+N+PE) 3 x 40 A (3L+N+PE)
(recom.) Dimensions H x 399 (9U) x 480 (19’) x 375 mm 311 (7U) x 480 (19’) x 465 mm
WxD
Dimensions H x W x D 222 (5U) x 444 (19’) x 315 mm 266 (6U) x 444 (19’) x 315 mm 177 (4U) x 495 (21’) x 315 mm 222 (5U) x 495 (21’) x 315 mm
Weight 30 kg 25 kg
Weight
AC input
AC input
AC configuration 3L+N+PE configurable 3L+N+PE configurable
AC configuration 3L+N+PE configurable 3L+N+PE configurable 3L+N+PE configurable 3L+N+PE configurable
Input voltage range 80 - 300 VRMS 80 - 300 VRMS
Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS
Frequency range 45 – 66 Hz 45 – 66 Hz
Frequency range 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz
Mains connection Screw terminals Screw terminals
Mains connection Screw terminals Screw terminals Screw terminals Screw terminals
DC output
DC output
Max. output current / 600 A / 34.8 kW 600 A / 20 kW
Max. output current / 250 A / 14,5 kW 250 A / 17.4 kW 250 A / 8.7 kW 250 A / 17.4 kW
max. installed power
max. installed power
Load breakers 14x MCB (up to 63 A)
Load breakers 15-21 x MCB (2-63 A) 15-21 x MCB (2-63 A) 18-24 x MCB (2-63 A) 18-24 x MCB (2-63 A)
Battery breakers 9x MHCB (up to 100A) or 4x MHCB (up to 200A) or 3x MHCB (up to 300A)
Optionally narrow load
21 x MCB (2-63 A) 25 x MCB (2-63 A) 25 x MCB (2-63 A)
breakers (13 mm) LVD (battery) Yes Yes
Battery breakers 2 x MHCB 50 A 2 x 100 A 2 x 100 A 2x MCB (80 – 125 A) PLD (not critical Optional Optional
loads)
LVD (battery) Yes Yes Yes Yes
Output protection Inbuilt fuses (both poles)
PLD (not critical loads) Optional Optional Optional Optional
Over-temperature protection
Output protection Inbuilt fuses (both poles)
Critical / non critical 6/8 6/8
Over-temperature protection
loads configuration
Critical / non critical 7/8 or 10/8 or 13/8 7/8 or 10/8 or 13/8 7/11 or 10/11 or 13/11 7/11 or 10/11 or 13/11
Control / monitoring 6/8 6/8
loads configuration

Control / monitoring Controller ORION; PSC 3

Controller ORION; PSC 3 Local interface Display, keypad, LEDs

Local interface Display, keypad, LEDs Remote monitoring Alarm relays, modem option, LAN, SNMP protocol

Remote monitoring Alarm relays, modem option, LAN, SNMP protocol Others

Others Operating -45 - +45 °C -45 - +45 °C


temperature
Operating temperature -45 - +65 °C -45 - +65 °C -45 - +65 °C -45 - +65 °C
Humidity (relative) 95 % max, non cond. 95 % max, non cond.
Humidity (relative) 95% max, non cond. 95% max, non cond. 95% max, non cond. 95% max, non cond.
Environment ETSI EN 300 019-1-3 ETSI EN 300 019-1-3
Environment standard ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 standard

Safety standard IEC 60950 IEC 60950 IEC 60950 IEC 60950 Safety standard IEC 60950 IEC 60950

EMC standard EN 300 386 EN 300 386 EN 300 386 EN 300 386 EMC standard EN 300 386 EN 300 386

Ordering Ordering

System 3799294100 3799294100 3799294100 3799294100 System 3791546100 3791546100

Rectifier ESR-48/56B F-S or ESR- ESR-48/56B F-S or ESR- ESR-48/56B F-S or ESR-48/56D ESR-48/56B F-S or ESR- Rectifier ESR-48/56B F-S or ESR-48/56D A-M TPS1010016C
48/56D A-M 48/56D A-M A-M 48/56D A-M
10 11

Additional Elements Indoor systems:


Site Support cabinets CabD
General SC600 SC770 SC1300 SC1800 SC2000

Internal space 12 U 15 U 27 U 38 U 42 U

Height 620 mm 759 mm 1295 mm 1790 mm 1961 mm


The Delta CabD product series offer high power-density
systems, ideal for space critical indoor applications.
Scalable
Width 600 mm

Depth 450 or 600 mm


CabD systems are built on modular basis and allow
flexibility in configuration.
Modular
Cooling Natural convention (no fans, no air filter)

Optional equipment Battery shelves (240 kg), 19’ or 21’ internal rails / supporters Front door or battery section covers, Rear panel
or steel crossing Blanking plates (1U, 2U and 3U) The system includes up to twelve rectifiers, AC and DC
Up to 97.2% efficiency
Ordering 3799295400 Configurator connections, battery connection and the Delta ORION
controller (more about the ORION controller on p. 18).

Wall Box

General WB 5U WB 8U WB 12U

Internal space 5 U / 19‘ 8 U / 19‘ 12 U / 19‘

Height 253 mm 387 mm 564 mm

Width 548 mm

Depth 475 mm

Cooling Natural convention (no fans, no air filter)

Optional equipment Front door, Blanking plates (1U, 2U and 3U) Main features
Ordering 3791518600 Configurator

• Scalable power system up to 144 kW per cabinet and max


768 kW parallel
• Truly modular building blocks
• Mirroring the system built for top entry or bottom entry for
AC Panel DC Panel cabling
• High efficiency rectifiers up to 97.2%
General APD 19IN-3U DPD 19IN-3U
• Enhanced monitoring and controlling with ORION controller

Applications
Optional equipment Screw terminals, Main switch, Circuit breakers (MCB, DC Load circuits breakers, max 24x or 27x MCB (up
RCD), Service sockets, Overvoltage protection to 63A), Two load groups: A and B with 10-14 x MCB
• Central offices
(OVP),Relays and contactors each, PLD contactor 250A ( critical and no critical loads • Mobile telephone switching offices
groups)
• Telecom, wireless, datacom
Operating voltage / AC: 230 / 400 V (1 or 3 ph) / Related to equipment DC: 20-60 V / 300 A • Data centers
Current (max.)
• Modular UPS configurations
Internal space 19IN: 24 modules (18 mm), 21IN: 27 modules (18 mm) 19IN: 24 modules (18 mm), 21IN: 27 modules (18 mm)
• Indoor and outdoor container
Dimensions H x 133 (3U) x 480 (19’) x 188 mm or 133 (3U) x 480 (19’) x 188 mm or
WxD 133 (3U) x 530 (21’) x 188 133 (3U) x 530 (21’) x 188

Ordering 3799374500 Configurator


12 13

CabD Technical Specifications Outdoor systems:


General CabD 600 CabD 1500
CabD Systems

CabD 3000
OutD
Delta OutD are cost-effective and high-density outdoor
systems, suitable for any climate. The OutD systems are
Choice between cost
equipped with advanced cooling solutions and ensure effective or fully optimised
remarkable savings in both capital and operational
expenditures. Additionally, all OutD products ensure low
modular configurations
noise levels and a multi lock mechanism.

Max. output current / 600 A / 34.8 kW 1500 A / 144 kW 3000 A / > 144 kW We offer a choice between a basic cost-effective
max. installed power
configuration and an optimized modular system alternative.
Rectifier module DPR 6000 (max. 8 pcs.), DPR 6000 (max. 12 pcs.), DPR 6000 ( max 24 pcs.)
DPR 4000 (max.12 pcs.) DPR 4000 (max. 18 pcs.), DPR 4000 (max. 36 pcs.),
DPR 2900 (max.12 pcs.)

Efficiency 95.2% ... 97,2% 95.2 % ... 96,5 % 95.2 % ... 96,5 %

AC configuration 3L+N+PE configurable

Load and battery Configurable – modular design

Applications
connection

LVD / PLD Option / Option Main features


Controlling and ORION / PSC 3
monitoring
• Modular • Network base stations
Operating temperature -5 - +45 °C • Flexible configuration • Wireless applications
Dimensions H x W x D Single cabinet:1800/2000/2200 x 600 x 600 Single or multiticabinets 1800/2000/2200 x Single or multiticabinets 1800/2000/2200 • Multiple thermal management options • Fixed line applications, data communications
mm 600 x 600/800 mm x 600 x 600/800 mm
• Enhanced noise management
Weight Depends on the configuration • Choice between cost effective or fully optimized
Ordering 3799363900 Configurator 3791691700 Configurator 3791691700 Configurator configuration

DC distribution (examples)
M series, passive cooling M series, active cooling V series, passive cooling V series, active cooling

AC input

Rectifier shelves

Batt. connections
NH00, NH2, NH3, EFEN 630A, MCB,
TPS2(1200/1600A)
14 15

OutD Technical Specifications Solutions: Renewable hybrid


General OutD M Series
OutD Systems

OutD V Series
RenE Reliable “green” power

The RenE product series are renewable-hybrid energy


Low OPEX
solutions that provide the network transmission site with
power from renewable solar and/or wind energy sources.
Up to 97.2% efficiency

RenE secures reliable and uninterrupted power supply All RenE systems can include a selected combination of
even in remote and rural areas with missing power network Orion PLC, Grid/Genset input, rectifiers, solar chargers,
or low network reliability. In combination with careful energy DC-converters, AC-inverters, power distribution unit for
Optimized modular design Basic and cost effective solution management from alternative sources, the system lowers solar and wind power, load and battery connections, as
Key advantages Flexible and modular Cost effective operational expenditure, minimizes the waste of energy well as optional automatic transfer switch (ATS). The
Battery box extension (battery cooler) Battery cooler (Separated battery compartment with advanced and can significantly drop CO2 emissions. systems are expandable with battery cabinets and racks
thermal insulation 40mm EPS and active cooling (TEC or AC)) with variable cooling options.
IP20 equipment extension
Single or Multilayer wall design
Side by side connection available
-7dB(A) (lower than standard cabinets with the same cooling
-7dB(A) (lower than standard cabinets with the same cooling capacity)
capacity)
Steel or aluminium outside walls

Flexible configuration - 19’ or 21’ racks, battery shelves,


multiple PSU options (power supply systems), multiple cable Main Features Applications
management options

Multiple colling options (AV, AC, Hybrid AC+AC)


• Power up to 12/24 kW, high power density • Wireless applications, network base stations
• Renewable green energy by wind and solar power • Remote areas with difficult site access

Dimensions OutD 1.8M - H1827 x W770 x D852 mm - 35HU OutD 1.8V - H1860 x W708 x D768mm - 35HU • Cyclic battery discharge for genset fuel efficiency • Areas with unreliable mains grid or off-grid
OutD 2.0M - H2050 x W870 x D952mm - 40HU OutD 2.0V – H2060 x W808 x D860mm - 39HU
• ORION controller for ultimate energy management
Protection class up to IP55 and site control
Efficiency is 95.0~95.9%
Material Steel or Aluminum, Single or multilayer with optional thermal isolation
Efficiency is 96.0~96.9%
Lifetime Steel : up to 15 year, Aluminium: up to 20 years Efficiency is 97.0~97.9%
Cooling options AV (Air Ventilation), HEX (Heat Exchanger,) AC (Air con), Hybrid AV+AC (Hybrid cooling Air Ventilation + Air con) Pantone 2665 C

Features Low audible noise emissions (-7dB) Basic solution for high runner applications
Assembling – disassembling on site, Flat packing Low audible noise emissions (-7dB)
Side by side and vertical extension modules
Rear door available, side panels removable

Options Cable Management: Delta universal, PG, Multigate, Roxtec, Service LED light, Smoke detectors, Flood water sensor, Blocked
filter sensors , High humidity sensor, Notebook shelf , Battery movable tray, Heaters, Alarm terminals (Krone, Screw) and much
more
16 17

RenE Technical Specifications Thermal Management


RenE-InD-300-48 RenE-InD-600-48 RenE-OutD-300-48 RenE-OutD-600-48

Input grid section

AC connection 3L + N + PE Active cooling Hybrid cooling


Nominal voltage 3 x 230 VRMS (L-N) Done via either AC or DC powered air conditioning The hybrid cooling systems allow intelligent temperature
Voltage range 88 - 300 VRMS system, the active cooling solutions are perfect for management. This cooling solution meets the challenges
Frequency range 45 - 66 Hz regions with significant temperature amplitudes. This of high amplitude temperatures while decreasing OPEX.
Current nominal / phase 25 ARMS 50 ARMS 25 ARMS 50 ARMS solution guarantees optimal temperatures at all times.
Mains terminal Terminal blocks, or main breaker

Input protection, Optional Passive cooling


transient OVP
Excellent solution for mild climates, both OPEX and
Input generator section
CAPEX friendly. Delta’s passive cooling solutions
AC connection 3L + N + PE
are designed with meticulous precision and deliver
Nominal voltage 3 x 230 VRMS (L-N)
outstanding results.
Current nominal / phase 25 ARMS 50 ARMS 25 ARMS 50 ARMS

Automatic transfer switch Voltage relay monitoring, mechanical interlocking (optional)

Mains terminal Terminal blocks, or main breaker


Active cooling Passive cooling Passive cooling Hybrid cooling
Input protection Optional
a) b)
Input renewable power section Fans Fans
Renewable DC 6 feeds 10A 12 feeds 10A 6 feeds 10A 12 feeds 10A
connection

Voltage range 70-350 Vdc

Current max / pole 10 ADC

Heat Exchanger
Input terminal 6x2P Switch 12x2P Switch 6x2P Switch 12x2P Switch

Air Con
Input protection Internal fuse

Transient protection 600Vdc/2+V

Output power section

Air Filter

Air Filter
Rectifier power 12 kW max 24 kW max 12 kW max 24 kW max

Solar power 6 x 2,2 kWpeak 12 x 2,2 kWpeak 6 x 2,2 kWpeak 12 x 2,2 kWpeak

Voltage range 42 - 58 Vdc; 53.5 Vdc nom

Battery MCB, MCB See CellD 300 specifications See CellD 600 specifications See CellD 300 specifications See CellD 600 specifications

LVLD 250 600A 250A 600A

PLD 250A, optional 250A, optional 250A, optional 250A, optional

Batt-capacity expansion n*600 Ah n*600 Ah n*600 Ah n*600 Ah Passive cooling Passive cooling
Active cooling Hybrid cooling
cabinet a) b)
AirCon AirCon Air to Air Thermo-Siphon AirCon + Air
Energy management section Air Ventilation
230Vac supply 48Vdc supply HEX HEX Ventilation
Energy management Configurable, depending on applied energy sources and OPEX saving targets 850 – 2000 W 800 – 2000 W AV – 250 W/KAC –
Cooling Capacity 100 ~ 250 W/K 80 ~ 160 W/K 100 ~ 600 W/K
@ L35/L35 @ L35/L35 2000 W
Thermal management Optional Optional Fans and filters Fans and filters
Power Consumption High High Very low Medium Medium Low
AC & genset mgt Automatic, configurable
AV – 26; AC –
Energy meter AC and DC power throughput Coefficient of
10 ~ 26 2.5. ~ 4.5 4,0 ~ 5,5 1,7 @ L35L35,
Performance (COP) 1,7~2,0 @ 35/35 1,6~4,0 @ 35/35
@ DT=5K @ DT=5K @ DT=5K DT=5K230Vac
General supply
Ambient temperature -5 - +45 °C -40 - +45 °C
Energy consumption
Safety IEC/EN 60950 OPEX

EMC EN 300 386 Investment CAPEX

Protection IP20, ETS 300 019 Part 1-3 IP55, ETS 300 019 Part 1-4

Ordering 3799279100 Configurator


18 19

Intelligence: ORION Technical Specifications


System and Site controller General

Voltage range
ORION

18 - 75 Vdc

Current 0.8 ADC (max)

Full site controller


ORION is a single full site controller solution for any size system, Input protection / switch Internal fuse 2A / none
supporting up to 128 rectifiers. ORION is easily expandable with Dimensions (H x W x D) 40.0 x 83.4 x 175 mm
CAN bus communication and a range of front-end modules.
Remote monitoring: iPhone
Weight 0.6 kg

ORION provides full site control, allowing management of all Standards


EN 60950, class I; UL 60950; CAN / CSA - C22.2
power system features. Monitoring reports and alarms are
available via the specifically designed iPhone application, LAN,
App, LAN, SNMP, Modbus •

Safety
EMC
EN 55022, class B; ETSI EN 300386 compliant

SNMP or Modbul. Battery management with capacity test and Cooling Natural air flow
life length prediction as well as enhanced rectifier functions,
including redundancy supervision, allow planning site visits in a
Integrates hybrid energy Operating temperature 0 to +65 ºC

Relative humidity 95%, non-condensing


cost-effective manner.
Functions
ORION is hot-pluggable, with easy configuration management System • PLC functionality for customizing and supervision and control of auxiliary devices
and supports various languages. All common battery profiles • AC measurement (internal / external)
are pre-configured. The controller supports both lead acid and
• Mains failure / phase failure detection and alarming
lithium ion batteries.
• LVD and PLD functions
• Advanced genset functions for fuel savings
• Configurable event and data log

Battery • Temperature compensated float charge / Boost and equalize charge


• Charging current limitation (advanced)
Main Features Applications • Low voltage disconnection, state of charge supervision and display
• Backup time supervision / life time prediction, automatic capacity test
• Remote monitoring with modem or LAN (Ethernet) • Network base transceiver stations • Symmetry supervision for voltage and currents
connection • Wireless network applications • Block voltage supervision (optional)

• Integrated, user friendly web-server for browser access, and • Fixed line network applications, data communications Rectifiers • Individual rectifier information and control
local HW display and keypad • Sequential start-up / system soft start
• Hybrid Power Plants and sites
• Integrated PLC (Programmable Logic Controller) functions • Efficiency mode with advanced rectifier cycling
to enhance modular flexibility • Redundancy and power capacity supervision

• Monitoring and controlling site infrastructure Temperature Humidity Genset Battery Features
detector detector management management
• PSU control, temperature detector, humidity detector, Grid/ Rectifier interface Digital, CAN-based
Genset management, battery management, performance
Number of rectifiers Up to 128
data, thermal control, access control, flood detector, smoke/
fire detector, intrusion detector, etc. Digital input From 4 up to 227

• Advanced battery management, supervision and testing Performance Flood Smoke Intrusion Relay output From 6 up to 99
methods data detector detector detector
Temperature From 2 up to 98
• Easy maintenance by pluggable architecture
Voltage, current Up to 200

Display 1 integrated, up to 2 user interface modules

Local monitoring LAN / WEB browser

Remote monitoring LAN / modem, GSM, GPRS / WEB browser/SNMP/Modbus

Remote alarming Dry contacts / SNMP/SMS

Languages English + 2 downloadable

User interface

Local user interface 5 configurable LEDs; LCD display; Keypad

UIM (optional) 5 configurable LEDs; LCD display; Keypad; Buzzer

Web Four different access levels; more than 200 dynamic web pages; SW and setup updates locally and remotely

SNMP Remote alarms using traps; Dial-out feature together with modems

Renewable
energy sources

Remote AC smart
management metering
20 21

Components: Rectifiers Technical Specifications


Rectifiers DPR 850-48 DPR 2900-48 DPR 2900-48 DPR 4000-48 DPR 6000-48

With energy efficiency of over 96%, Delta’s EnergE Efficiency


rectifiers are the new benchmark in power density.
95.2% 96.4% 96.5% 97.2%
Pantone 2665 C Pantone 2665 C

EnergE series rectifiers are designed for medium to high 850W


power applications and serve for up to 7% lower site

Power output
DPR 850-48
energy consumption, delivering significant OPEX savings. Output
2900W
Additional benefits are the lower temperature management DPR 2900-48 DPR 2900-48
Nominal system 53.5 V 54.0 V 54.0 V 53.5 V 53.5 V
requirements and lower CO2 emissions. voltage
4000W
DPR 4000-48 Operating voltage 42 - 58 V 40 - 58 V 42 - 58 V 42 - 58 V 42 - 58 V
Delta’s rectifiers are hot-pluggable and can be installed on range
any system. 6000W Power output 850 W 2900 W 2900 W 4000 W 6000 W
DPR 6000-48
Efficiency 95.2% 96.4% 97.2% 95.2% 96.5%

Current limitation 17.7 A 56.25 A 56.25 A 83.3 A 125.0 A

Input

Mains voltage 80 – 300VAC 80 – 310VAC 90 – 300VAC 80 – 300VAC 250 - 530 VAC (3ph)

Mains frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz

Efficiency is 95.0~95.9% Protection Internal fuse 2 x8A (L,N) Internal fuse 20A Internal fuse 20A Internal fuse 2 x 30A Internal fuse 3 x 20A

General
Efficiency is 96.0~96.9% Power density 30 W / in3 36.5 W / in3 36.5 W / in3 27.3 W / in3 26.5 W / in3

Efficiency is 97.0~97.9% Control and


ORION, PSC 3
monitoring
Pantone 2665 C

Hot-pluggable Yes Yes Yes Yes Yes

Dimensions
51.8 x 40.0 x 247.2 mm 125.5 x 41.0 x 269.9 mm 125.5 x 41.0 x 269.9 mm 82.0 x 86.9 x 377.9 mm 129.5 x 83.0 x 380.7 mm
(W x H x D)

Weight 0.6 kg 2.0 kg 2.0 kg 3.5 kg 5.2 kg

Cooling Fan cooled with speed control

Acoustics

Operating
-40 to + 75 °C -40 to + 75 °C -40 to + 75 °C -45 to + 75 °C -40 to + 70 °C
temperature

Standards

Safety EN / IEC 60950; UL 60950; CAN / CSA – C22.2

EMI (radiated) EN 55022 class B

Environment RoHS compliant

Ordering

Order numbers TPS1010004A-PML-M ESR-48/56B F-A ESR-48/56D A-M TPS1010016C

Main Features Applications


• Market leaders in power density - an essential feature in electronic
devices as it defines the product’s energy conversion capability in • Network base stations
relation to its size • Wireless applications
• Small size – Delta EnergE rectifiers require less cabinet space • Fixed line applications, data communications
than competing products
• Advanced over voltage protection - fewer maintenance trips to the
site
• High operation temperatures - EnergE rectifiers also tolerate high
operating temperatures, which delivers additional savings. For
example, a temperature increase from 40 °C to 50 °C at the site
creates savings of over 6%
22

Services

Engineering
During our extensive experience in the telecom power field, at Delta we have
learned that some client needs can be truly unique. Such circumstances
require special solutions and we are there to provide them. Our team of
highly qualified engineers is available to work with these clients and develop
specially engineered solutions to match their unique challenges based on
our standard product portfolio, standardization efforts and building block
philosophy.
Consulting
At Delta we don’t just provide power electronics, we work to solve our
customers’ challenges. Our team is always prepared to work together
with the customer in order to find the best solution for their situation, Maintenance
providing real network expertise. Our subject matter experts possess We offer maintenance services for all our products. Our
the knowledge and experience to understand our clients’ challenges experienced technicians are well trained and have the
and to provide valuable consult and advice. knowledge needed to deliver seamless maintenance and assure
uninterrupted working processes using as well remote monitoring
tools providing the advantages of speed and flexibility.

Training
Delta’s engineers are available to facilitate training programs and
refreshers, tailored to the client’s specific needs. We will develop the
content so that it serves our clients’ individual needs and solves their
specific challenges.
Hot line
For our clients’ convenience, we provide a customer service hot
line, customized to their real needs. This can cover the standard
office hours as well as a full 24h service line day by day to ensure
highest customer satisfaction.
Installation & Commissioning
Installation and commissioning can be a long and costly process, demanding
a lot of recourses, time, and most of all - manpower. This is why we are
glad to offer you our installation and commissioning services. Our people
are well trained and have excellent knowledge of the equipment. They will
make sure that your network runs smoothly and within the set timeframes.
Delta EMEA Headquarters

Netherlands
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands
email: info.europe@delta-es.com
Tel: +31 20 655 0900

Delta Telecom Power - EMEA Locations


Czech Republic Slovakia - assembly, testing & logistics center EMEA
Perucka 2482/7 120 00 Praha 2, Czech Republic Priemyselna ulica 4600/1, 018 41 Dubnica nad Vahom, Slovakia
Tel: +420 272 019 330 Tel: +421 42 466 1111

Dubai South Africa


Gate 7, 3rd Floor, Hamarain Centre, Unit 305B Lougardia Building Centurion, Pretoria, South Arica
Dubai, United Arab Emirates
Spain
Finland Calle Luis I n° 60, Nave 1a P.I. de Vallecas 28031 Madrid, Spain
Juvan teollisuuskatu 15, 02921 Espoo, Finland Tel: + 34 91 223 74 20
Tel: +358 9 849 660
Sweden
France P.O. Box 3096 SE 350 33 Växjö, Sweden
ZI du bois Chaland 2 15 rue des Pyrénées, Tel: +46 470 706 800
Lisses 91056 Evry Cedex, France
Tel: +33 1 69 77 82 60 Switzerland
Freiburgstrasse 251, 3018 Bern Bümpliz, Switzerland
Germany Tel: +41 31 998 53 11
Coesterweg 45, D 59494 Soest, Germany
Tel: +49 2921 987 0 Turkey
Serifali Mevkii Barboros Bulvari Soylesi Sok No 19 Y.Dudullu-Umraniye/
Istanbul, Turkey
Italy Tel: +90 216 499 9910
Piazza Grazioli 18 00186 Roma, Italy
Tel: +39 06 69941209
United Kingdom
Greenside Way, Middleton, Manchester, M24 1XX, United Kingdom
Poland Tel: +44 161 947 3300
23 Poleczki Str. 02 822 Warsaw, Poland
Tel: +48 22 335 26 00

Russia
Vereyskaya Plaza II, office 401 Vereyskaya str.17
121357 Moscow, Russia
Tel: +7 495 644 3240

www.deltapowersolutions.com
© 2014 Delta Electronics, Inc, All Rights Reserved