Professional Documents
Culture Documents
Rectificadores Delta
Rectificadores Delta
Telecommunications
Flexible and modular telecom solutions for
Europe, Middle East and Africa
www.deltapowersolutions.com
2 3
Thermal Management 17
7000+ 23 16 310 All Delta products delivered in the EMEA region are
assembled, tested and serviced from our assembly and
R&D engineers R&D labs manufacturing patents service center in Slovakia.
worldwide plants
Having a local hub within Europe assures full compliance
with all European quality requirements, quick assembly,
excellent service and shorter delivery times.
Certifications:
ISO 9001
ISO 14001
CSH OHSAS 18000
US$ Millions
0.04 4,846 6,609 7,081 7,101 7,180
33.4%
1971
2009
2010
2011
2012
2013
Installed power
power density. 125A 8.7kW
DPS 2900B-48-3
Efficiency 95.2% 95.2% 96.4% or 97,2% 96.2% or 97,2%
14.5kW
CellD units can be installed alongside other equipment, in DPS 2900B-48-5 19IN-5U
Install power (max. 2.55 kW 5.1 kW 8.7 kW 8.7 kW
an existing rack for example. They work seamlessly and at 17.4kW
config.)
DPS 2900B-48-6 19IN-6U
optimal efficiency up to more then 97% with Delta’s EnergE 300A
Input protection 25 A gL/gG fuse 3 x 10 A (3L+N+PE) 3 x 20 A (3L+N+PE) 3 x 20 A (3L+N+PE)
(recom.)
rectifiers and advanced controllers. This configuration 8.7kW
DPS 2900B-48-3 21IN-4U Dimensions H x W x D 43.6 (1U) x 444 (19’) x 280 mm 86.8 (2U) x 444 (19’) x 295 mm 86.8 (2U) x 444 (19’) x 323 mm 133.5 (3U) x 481.5 (19’) x 329 mm
ensures reliable system operation, generates savings in
Weight 4.1 kg 7.0 kg 7.0 kg 15 kg
OPEX and CO2, and maximizes battery lifetime. 17.4kW
DPS 2900B-48-6 21IN-5U AC input
DC output
Max. output current / 40 A / 2.55 kW 100 A / 5.1 kW 100 A / 8.7 kW 125 A / 8.7 kW
max. installed power
Control / monitoring
Others
• Wide DC power range – systems available from 40A up to • Wireless applications, network
600A base stations, applications, Operating temperature -45 - +65 °C -45 - +65 °C -45 - +65 °C -45 - +65 °C
• Extremely wide input AC voltage range – for all AC networks broadband services Humidity (relative) 95% max, non cond. 95% max, non cond. 95% max, non cond. 95% max, non cond.
in any location (80 … 300 Vac). Also for applications where • Transmission
Environment standard ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3
only a low quality AC grid is available • Modular UPS configurations
• Wide operating temperatures (-45 °C… +65 °C) Safety standard IEC 60950 IEC 60950 IEC 60950 IEC 60950
• Indoor and outdoor containers
• Modular structure and configuration adjusted to customer • Telecom, wireless, datacom EMC standard EN 300 386 EN 300 386 EN 300 386 EN 300 386
requirements
• Containers/shelters Ordering
• Highest efficiency – CellD systems use high-efficiency
System 3799321900 3799361100 3799361100 3791605600
EnergE rectifiers
• 19’’ platform – universal 19” rack mounted modules can be Rectifier TPS1010004B-PML-M TPS1010004B-PML-M ESR-48/56B F-S or ESR-48/56D ESR-48/56B F-S or ESR-48/56D
installed in different 19” structures and cabinets. Efficiency is 95.0~95.9% A-M A-M
• Advanced monitoring – state-of-the-art controllers ORION,
PSC 3; 6 alarm relays, modems, WEB Interface, SNMP Efficiency is 96.0~96.9%
protocol Efficiency is 97.0~97.9%
• Hot plug modules and components Pantone 2665 C
8 9
General DPS 2900B-48-5 19IN-5U DPS 2900B-48-6 19IN-6U DPS 2900B-48-3 21IN-4U DPS 2900B-48-6 21IN-5U
Rectifier module DPR 2900B-48 (max. 12 pcs.) DPR 4000B-48 (max. 5 pcs.)
Rectifier module DPR 2900B-48 (max. 5 pcs.) DPR 2900B-48 (max. 6 pcs.) DPR 2900B-48 (max. 3 pcs.) DPR 2900B-48 (max. 6 pcs.) Efficiency 96.4% or 97,2% 95.2%
Efficiency 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% Install power (max. 34.8 kW 20 kW
config.)
Install power (max. 14.5 kW 17.4 kW 8.7 kW2 17.4 kW
config.) Input protection 2 x (3 x 40 A) 3 x 50 A
(recom.)
Input protection 3 x 40 A (3L+N+PE) 3 x 40 A (3L+N+PE) 3 x 20 A (3L+N+PE) 3 x 40 A (3L+N+PE)
(recom.) Dimensions H x 399 (9U) x 480 (19’) x 375 mm 311 (7U) x 480 (19’) x 465 mm
WxD
Dimensions H x W x D 222 (5U) x 444 (19’) x 315 mm 266 (6U) x 444 (19’) x 315 mm 177 (4U) x 495 (21’) x 315 mm 222 (5U) x 495 (21’) x 315 mm
Weight 30 kg 25 kg
Weight
AC input
AC input
AC configuration 3L+N+PE configurable 3L+N+PE configurable
AC configuration 3L+N+PE configurable 3L+N+PE configurable 3L+N+PE configurable 3L+N+PE configurable
Input voltage range 80 - 300 VRMS 80 - 300 VRMS
Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS
Frequency range 45 – 66 Hz 45 – 66 Hz
Frequency range 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz
Mains connection Screw terminals Screw terminals
Mains connection Screw terminals Screw terminals Screw terminals Screw terminals
DC output
DC output
Max. output current / 600 A / 34.8 kW 600 A / 20 kW
Max. output current / 250 A / 14,5 kW 250 A / 17.4 kW 250 A / 8.7 kW 250 A / 17.4 kW
max. installed power
max. installed power
Load breakers 14x MCB (up to 63 A)
Load breakers 15-21 x MCB (2-63 A) 15-21 x MCB (2-63 A) 18-24 x MCB (2-63 A) 18-24 x MCB (2-63 A)
Battery breakers 9x MHCB (up to 100A) or 4x MHCB (up to 200A) or 3x MHCB (up to 300A)
Optionally narrow load
21 x MCB (2-63 A) 25 x MCB (2-63 A) 25 x MCB (2-63 A)
breakers (13 mm) LVD (battery) Yes Yes
Battery breakers 2 x MHCB 50 A 2 x 100 A 2 x 100 A 2x MCB (80 – 125 A) PLD (not critical Optional Optional
loads)
LVD (battery) Yes Yes Yes Yes
Output protection Inbuilt fuses (both poles)
PLD (not critical loads) Optional Optional Optional Optional
Over-temperature protection
Output protection Inbuilt fuses (both poles)
Critical / non critical 6/8 6/8
Over-temperature protection
loads configuration
Critical / non critical 7/8 or 10/8 or 13/8 7/8 or 10/8 or 13/8 7/11 or 10/11 or 13/11 7/11 or 10/11 or 13/11
Control / monitoring 6/8 6/8
loads configuration
Local interface Display, keypad, LEDs Remote monitoring Alarm relays, modem option, LAN, SNMP protocol
Remote monitoring Alarm relays, modem option, LAN, SNMP protocol Others
Safety standard IEC 60950 IEC 60950 IEC 60950 IEC 60950 Safety standard IEC 60950 IEC 60950
EMC standard EN 300 386 EN 300 386 EN 300 386 EN 300 386 EMC standard EN 300 386 EN 300 386
Ordering Ordering
Rectifier ESR-48/56B F-S or ESR- ESR-48/56B F-S or ESR- ESR-48/56B F-S or ESR-48/56D ESR-48/56B F-S or ESR- Rectifier ESR-48/56B F-S or ESR-48/56D A-M TPS1010016C
48/56D A-M 48/56D A-M A-M 48/56D A-M
10 11
Internal space 12 U 15 U 27 U 38 U 42 U
Optional equipment Battery shelves (240 kg), 19’ or 21’ internal rails / supporters Front door or battery section covers, Rear panel
or steel crossing Blanking plates (1U, 2U and 3U) The system includes up to twelve rectifiers, AC and DC
Up to 97.2% efficiency
Ordering 3799295400 Configurator connections, battery connection and the Delta ORION
controller (more about the ORION controller on p. 18).
Wall Box
General WB 5U WB 8U WB 12U
Width 548 mm
Depth 475 mm
Optional equipment Front door, Blanking plates (1U, 2U and 3U) Main features
Ordering 3791518600 Configurator
Applications
Optional equipment Screw terminals, Main switch, Circuit breakers (MCB, DC Load circuits breakers, max 24x or 27x MCB (up
RCD), Service sockets, Overvoltage protection to 63A), Two load groups: A and B with 10-14 x MCB
• Central offices
(OVP),Relays and contactors each, PLD contactor 250A ( critical and no critical loads • Mobile telephone switching offices
groups)
• Telecom, wireless, datacom
Operating voltage / AC: 230 / 400 V (1 or 3 ph) / Related to equipment DC: 20-60 V / 300 A • Data centers
Current (max.)
• Modular UPS configurations
Internal space 19IN: 24 modules (18 mm), 21IN: 27 modules (18 mm) 19IN: 24 modules (18 mm), 21IN: 27 modules (18 mm)
• Indoor and outdoor container
Dimensions H x 133 (3U) x 480 (19’) x 188 mm or 133 (3U) x 480 (19’) x 188 mm or
WxD 133 (3U) x 530 (21’) x 188 133 (3U) x 530 (21’) x 188
CabD 3000
OutD
Delta OutD are cost-effective and high-density outdoor
systems, suitable for any climate. The OutD systems are
Choice between cost
equipped with advanced cooling solutions and ensure effective or fully optimised
remarkable savings in both capital and operational
expenditures. Additionally, all OutD products ensure low
modular configurations
noise levels and a multi lock mechanism.
Max. output current / 600 A / 34.8 kW 1500 A / 144 kW 3000 A / > 144 kW We offer a choice between a basic cost-effective
max. installed power
configuration and an optimized modular system alternative.
Rectifier module DPR 6000 (max. 8 pcs.), DPR 6000 (max. 12 pcs.), DPR 6000 ( max 24 pcs.)
DPR 4000 (max.12 pcs.) DPR 4000 (max. 18 pcs.), DPR 4000 (max. 36 pcs.),
DPR 2900 (max.12 pcs.)
Efficiency 95.2% ... 97,2% 95.2 % ... 96,5 % 95.2 % ... 96,5 %
Applications
connection
DC distribution (examples)
M series, passive cooling M series, active cooling V series, passive cooling V series, active cooling
AC input
Rectifier shelves
Batt. connections
NH00, NH2, NH3, EFEN 630A, MCB,
TPS2(1200/1600A)
14 15
OutD V Series
RenE Reliable “green” power
RenE secures reliable and uninterrupted power supply All RenE systems can include a selected combination of
even in remote and rural areas with missing power network Orion PLC, Grid/Genset input, rectifiers, solar chargers,
or low network reliability. In combination with careful energy DC-converters, AC-inverters, power distribution unit for
Optimized modular design Basic and cost effective solution management from alternative sources, the system lowers solar and wind power, load and battery connections, as
Key advantages Flexible and modular Cost effective operational expenditure, minimizes the waste of energy well as optional automatic transfer switch (ATS). The
Battery box extension (battery cooler) Battery cooler (Separated battery compartment with advanced and can significantly drop CO2 emissions. systems are expandable with battery cabinets and racks
thermal insulation 40mm EPS and active cooling (TEC or AC)) with variable cooling options.
IP20 equipment extension
Single or Multilayer wall design
Side by side connection available
-7dB(A) (lower than standard cabinets with the same cooling
-7dB(A) (lower than standard cabinets with the same cooling capacity)
capacity)
Steel or aluminium outside walls
Dimensions OutD 1.8M - H1827 x W770 x D852 mm - 35HU OutD 1.8V - H1860 x W708 x D768mm - 35HU • Cyclic battery discharge for genset fuel efficiency • Areas with unreliable mains grid or off-grid
OutD 2.0M - H2050 x W870 x D952mm - 40HU OutD 2.0V – H2060 x W808 x D860mm - 39HU
• ORION controller for ultimate energy management
Protection class up to IP55 and site control
Efficiency is 95.0~95.9%
Material Steel or Aluminum, Single or multilayer with optional thermal isolation
Efficiency is 96.0~96.9%
Lifetime Steel : up to 15 year, Aluminium: up to 20 years Efficiency is 97.0~97.9%
Cooling options AV (Air Ventilation), HEX (Heat Exchanger,) AC (Air con), Hybrid AV+AC (Hybrid cooling Air Ventilation + Air con) Pantone 2665 C
Features Low audible noise emissions (-7dB) Basic solution for high runner applications
Assembling – disassembling on site, Flat packing Low audible noise emissions (-7dB)
Side by side and vertical extension modules
Rear door available, side panels removable
Options Cable Management: Delta universal, PG, Multigate, Roxtec, Service LED light, Smoke detectors, Flood water sensor, Blocked
filter sensors , High humidity sensor, Notebook shelf , Battery movable tray, Heaters, Alarm terminals (Krone, Screw) and much
more
16 17
Heat Exchanger
Input terminal 6x2P Switch 12x2P Switch 6x2P Switch 12x2P Switch
Air Con
Input protection Internal fuse
Air Filter
Air Filter
Rectifier power 12 kW max 24 kW max 12 kW max 24 kW max
Solar power 6 x 2,2 kWpeak 12 x 2,2 kWpeak 6 x 2,2 kWpeak 12 x 2,2 kWpeak
Battery MCB, MCB See CellD 300 specifications See CellD 600 specifications See CellD 300 specifications See CellD 600 specifications
Batt-capacity expansion n*600 Ah n*600 Ah n*600 Ah n*600 Ah Passive cooling Passive cooling
Active cooling Hybrid cooling
cabinet a) b)
AirCon AirCon Air to Air Thermo-Siphon AirCon + Air
Energy management section Air Ventilation
230Vac supply 48Vdc supply HEX HEX Ventilation
Energy management Configurable, depending on applied energy sources and OPEX saving targets 850 – 2000 W 800 – 2000 W AV – 250 W/KAC –
Cooling Capacity 100 ~ 250 W/K 80 ~ 160 W/K 100 ~ 600 W/K
@ L35/L35 @ L35/L35 2000 W
Thermal management Optional Optional Fans and filters Fans and filters
Power Consumption High High Very low Medium Medium Low
AC & genset mgt Automatic, configurable
AV – 26; AC –
Energy meter AC and DC power throughput Coefficient of
10 ~ 26 2.5. ~ 4.5 4,0 ~ 5,5 1,7 @ L35L35,
Performance (COP) 1,7~2,0 @ 35/35 1,6~4,0 @ 35/35
@ DT=5K @ DT=5K @ DT=5K DT=5K230Vac
General supply
Ambient temperature -5 - +45 °C -40 - +45 °C
Energy consumption
Safety IEC/EN 60950 OPEX
Protection IP20, ETS 300 019 Part 1-3 IP55, ETS 300 019 Part 1-4
Voltage range
ORION
18 - 75 Vdc
SNMP or Modbul. Battery management with capacity test and Cooling Natural air flow
life length prediction as well as enhanced rectifier functions,
including redundancy supervision, allow planning site visits in a
Integrates hybrid energy Operating temperature 0 to +65 ºC
• Integrated, user friendly web-server for browser access, and • Fixed line network applications, data communications Rectifiers • Individual rectifier information and control
local HW display and keypad • Sequential start-up / system soft start
• Hybrid Power Plants and sites
• Integrated PLC (Programmable Logic Controller) functions • Efficiency mode with advanced rectifier cycling
to enhance modular flexibility • Redundancy and power capacity supervision
• Monitoring and controlling site infrastructure Temperature Humidity Genset Battery Features
detector detector management management
• PSU control, temperature detector, humidity detector, Grid/ Rectifier interface Digital, CAN-based
Genset management, battery management, performance
Number of rectifiers Up to 128
data, thermal control, access control, flood detector, smoke/
fire detector, intrusion detector, etc. Digital input From 4 up to 227
• Advanced battery management, supervision and testing Performance Flood Smoke Intrusion Relay output From 6 up to 99
methods data detector detector detector
Temperature From 2 up to 98
• Easy maintenance by pluggable architecture
Voltage, current Up to 200
User interface
Web Four different access levels; more than 200 dynamic web pages; SW and setup updates locally and remotely
SNMP Remote alarms using traps; Dial-out feature together with modems
Renewable
energy sources
Remote AC smart
management metering
20 21
Power output
DPR 850-48
energy consumption, delivering significant OPEX savings. Output
2900W
Additional benefits are the lower temperature management DPR 2900-48 DPR 2900-48
Nominal system 53.5 V 54.0 V 54.0 V 53.5 V 53.5 V
requirements and lower CO2 emissions. voltage
4000W
DPR 4000-48 Operating voltage 42 - 58 V 40 - 58 V 42 - 58 V 42 - 58 V 42 - 58 V
Delta’s rectifiers are hot-pluggable and can be installed on range
any system. 6000W Power output 850 W 2900 W 2900 W 4000 W 6000 W
DPR 6000-48
Efficiency 95.2% 96.4% 97.2% 95.2% 96.5%
Input
Mains voltage 80 – 300VAC 80 – 310VAC 90 – 300VAC 80 – 300VAC 250 - 530 VAC (3ph)
Mains frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Efficiency is 95.0~95.9% Protection Internal fuse 2 x8A (L,N) Internal fuse 20A Internal fuse 20A Internal fuse 2 x 30A Internal fuse 3 x 20A
General
Efficiency is 96.0~96.9% Power density 30 W / in3 36.5 W / in3 36.5 W / in3 27.3 W / in3 26.5 W / in3
Dimensions
51.8 x 40.0 x 247.2 mm 125.5 x 41.0 x 269.9 mm 125.5 x 41.0 x 269.9 mm 82.0 x 86.9 x 377.9 mm 129.5 x 83.0 x 380.7 mm
(W x H x D)
Acoustics
Operating
-40 to + 75 °C -40 to + 75 °C -40 to + 75 °C -45 to + 75 °C -40 to + 70 °C
temperature
Standards
Ordering
Services
Engineering
During our extensive experience in the telecom power field, at Delta we have
learned that some client needs can be truly unique. Such circumstances
require special solutions and we are there to provide them. Our team of
highly qualified engineers is available to work with these clients and develop
specially engineered solutions to match their unique challenges based on
our standard product portfolio, standardization efforts and building block
philosophy.
Consulting
At Delta we don’t just provide power electronics, we work to solve our
customers’ challenges. Our team is always prepared to work together
with the customer in order to find the best solution for their situation, Maintenance
providing real network expertise. Our subject matter experts possess We offer maintenance services for all our products. Our
the knowledge and experience to understand our clients’ challenges experienced technicians are well trained and have the
and to provide valuable consult and advice. knowledge needed to deliver seamless maintenance and assure
uninterrupted working processes using as well remote monitoring
tools providing the advantages of speed and flexibility.
Training
Delta’s engineers are available to facilitate training programs and
refreshers, tailored to the client’s specific needs. We will develop the
content so that it serves our clients’ individual needs and solves their
specific challenges.
Hot line
For our clients’ convenience, we provide a customer service hot
line, customized to their real needs. This can cover the standard
office hours as well as a full 24h service line day by day to ensure
highest customer satisfaction.
Installation & Commissioning
Installation and commissioning can be a long and costly process, demanding
a lot of recourses, time, and most of all - manpower. This is why we are
glad to offer you our installation and commissioning services. Our people
are well trained and have excellent knowledge of the equipment. They will
make sure that your network runs smoothly and within the set timeframes.
Delta EMEA Headquarters
Netherlands
Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands
email: info.europe@delta-es.com
Tel: +31 20 655 0900
Russia
Vereyskaya Plaza II, office 401 Vereyskaya str.17
121357 Moscow, Russia
Tel: +7 495 644 3240
www.deltapowersolutions.com
© 2014 Delta Electronics, Inc, All Rights Reserved