CONTENT:
• Structural loads.
• Load distribution system.
• Structural members.
• Structural Typology.
Structural load :
Structural loads are forces, deformations, or accelerations applied to a structure or its components.
Types of loads
• Dead load
• Loads that are relatively constant over time.
• Also known as permanent or static loads.
• Live load
• Dynamic or impose or moving loads,
temporary of short duration.
• Considerations: impact, momentum,
vibration, slosh dynamic of fluid.
• Environmental loads
These are loads that act as a result of weather,
topography and other natural phenomena. These are:
• Seismic load
• Snow, rain and ice load
• Wind loads
• Thermal loads (temperature changes leading to thermal expansion)
• Lateral pressure of soil, groundwater or bulk materials
Reference: Wikipedia
Seismic Load:
• Buildings undergoes dynamic motion
during earthquake.
• Building is subjected to inertia forces
that act in opposite direction to the
acceleration of earthquake
excitations.
• These inertia forces, called seismic
loads, are usually dealt with by
assuming forces external to the
building.
Reference: http://www.aij.or.jp/jpn/symposium/2006/loads/Chapter7_com.pdf
Foundation diagram for resisting seismic load
Reference: http://www.aij.or.jp/jpn/symposium/2006/loads/Chapter7_com.pdf
Wind Load:
Wind load has the ability to bring a building to
sway.
V max.
Plan view
WIND TURBULENCE :
When any moving air mass meets an obstruction,
such as building, it responds like any fluids by
moving to each side, then rejoining the major
airflow.
Column :
A rigid relativity slender structural member designed
primarily to support axial compressive loads
applied at the member ends.
In high rise buildings it can be use as mega column,
concrete filled tubular(CFT) etc.
Shear wall:
A vertical diaphragm or wall acting as a thin, deep
cantilever beam in loads to the ground foundation.
Bracing :
It is a structural element for positioning,
supporting, strengthening or restraining the
member of a structural frame.
Core :
Core is one of the most important structural and functional
elements of the high rise building.
The core of a building is the area reserved for elevators’ stairs,
mechanical equipments and the vertical shafts that are necessary
for ducts, pipes and wires.
Its wall are also the most common location for the vertical wind
bracing.
The placement of the service core stems from four generic types
which are :
- Central core
- Split core
- End core
- Atrium core
According to Mir M. Ali and Kyoung Sun Moon, Structural systems of tall buildings
can be divided into two broad categories-
INTERIOR STRUCTURES
By clustering steel columns and beams in the core, engineers create a stiff
backbone that can resist tremendous wind forces. The inner core is used as
an elevator shaft , and the design allows lots of open space on each floor
Interior structure
1. Rigid Frames
2. Shear Wall Hinged Frames
3. Shear Wall (or Shear Truss) -
Frame Interaction System
4. Outrigger Structures
EXTERIOR STRUCTURES
In newer skyscrapers, like the Sears Tower in Chicago, engineers moved the
columns and beams from the core to the perimeter, creating a hollow, rigid
tube as strong as the core design, but weighing much, much less.
Exterior structure
1. Tube
2. Diagrid
3. Space Truss Structures
4. Super frames
5. Exo-skeleton
INTERIOR STRUCTURE
The two basic types of lateral load-
resisting systems in the category of
interior structures are the moment-
resisting frames and shear
trusses/shear walls.
1. Rigid Frames:
• When shear trusses or shear walls are combined with MRFs, a shear truss (or
shear wall)-frame interaction system results.
• The upper part of the truss is restrained by the frame, whereas at the lower
part, the shear wall or truss restrains the frame.
Sub category :
1. Braced Rigid Frames
2. Shear Wall Rigid Frames
Braced Rigid Frames
Empire
state
building
Seagram
Building, up to
the 17th floor
(New York,
USA, 38 stories,
157 m)
Material:
Concrete
Shear Wall +
Steel Rigid
Frame
Cook County
Administration
Building, former
Brunswick Building
(Chicago, USA, 38
stories, 145 m)
Material:
Concrete
Shear Wall +
Concrete
Frame
OUTRIGGER SYSTEM
• Outriggers serve to reduce the overturning moment in the core that would otherwise
act as pure cantilever, and to transfer the reduced moment to the outer columns
through the outriggers connecting the core to these columns.
• The core may be centrally located with outriggers extending on both sides or in some cases it
may be located on one side of the building with outriggers extending to the building
columns on the other side.
• The outriggers are generally in the form of trusses in steel structures, or walls in concrete
structures.
Effectively resists bending by exterior columns connected
to outriggers extended from the core.
Belt truss
EXTERIOR STRUCTURE
1. Tube system
• In the simplest incarnation of the tube, The different tubular systems are-
the perimeter of the exterior consists of
closely spaced columns that are tied
together with deep spandrel beams Framed tube
through moment connections. Braced tube
Bundled tube
• This assembly of columns and beams Tube in tube
forms a rigid frame that amounts to a
dense and strong structural wall along
the exterior of the building.
FRAMED TUBE
• In a framed tube system, which is the basic tubular form, the building has closely spaced
columns and deep spandrel beams rigidly connected together throughout the exterior frames.
• Exterior column spacing should be from 5 to 15ft (1.5 to 4.5m) on centers. Practical spandrel beam
depths should vary from 24 to 48in (600 to 1200mm)
• The axial forces in the corner columns are the greatest and the distribution is non-linear for both the
web frame (i.e., frame parallel to wind), and the flange frame (i.e., frame perpendicular to wind).
• This is because the axial forces in the columns toward the middle of the flange frames lag behind those
near the corner due to the nature of a framed tube which is different from a solid-wall tube. This
phenomenon is known as shear lag.
• The purpose is to limit the shear lag effect and aim for more cantilever-type behavior of the
structure.
• A reasonable and practical limits can be a cantilever deflection of 50 to 80 percent of the total
lateral sway of the building.
Aon Center (Chicago, USA, 83 stories, 346 m)
The framed tube becomes progressively inefficient over 60 stories since the web frames
begin to behave as conventional rigid frames. Consequently, beam and column designs
are controlled by bending action, resulting in large size. In addition, the cantilever
behavior of the structure is thus undermined and the shear lag effect is aggravated.
BRACED TUBE
• A braced tube overcomes this problem by stiffening the perimeter frames in
their own planes.
• This concept stems from the fact that instead of using closely spaced perimeter
columns, it is possible to stiffen the widely spaced columns by diagonal
braces to create wall-like characteristics.
• The braces also collect gravity loads from floors and act as inclined columns.
• Therefore, the columns can be more widely spaced and the sizes of spandrels
and columns can be smaller than those needed for framed tubes, allowing for
larger window openings than in the framed tubes (Khan, 1967).
John Hancock Center (Chicago, USA, 100 stories 344 m)
Architect: Skidmore, Owings & Merril
Braced
frame
Onterie Center (Chicago, 58 stories, 174 m)
Architect: Skidmore, Owings & Merril
Braced frame
BUNDLED TUBE
Bundle
Tubes
TUBE IN TUBE
• For diagrid structures, almost all the conventional vertical columns are eliminated.
• This is possible because the diagonal members in diagrid structural systems can
carry gravity loads as well as lateral forces due to their triangulated
configuration in a distributive and uniform manner.
• Efficiently resists lateral shear by axial forces in the diagonal members but have
Complicated joints.
30 St Mary Axe, also known as Swiss Re Triangular steel frame
Building (London, UK, 41 stories, 181 m)
Material /Configuration : • Steel framed tube type
structural system
STEEL • Triangular steel frame
generates the tube
• Beams are supported by
diagonal steel member
• Requires less steel then
conventional steel frame
• The concept of super frame can be used in various ways for tall buildings, such as the
56-story tall Parque Central Complex Towers of 1979 in Caracas, Venezuela and the
168-story tall Chicago World Trade Center proposed by Fazlur Khan in 1982 (Ali,
2001; Iyengar, 1986).
Parque Central
Complex Towers
• Fire proofing of the system is not a serious issue due to its location outside the
building line.
Exterior skeloton
References :
• Council on Tall Buildings and Urban Habitat. (CTBUH)
• Structural Developments in Tall Buildings: Current Trends and Future
Prospects -Mir M. Ali† and Kyoung Sun Moon
• http://www.aij.or.jp/jpn/symposium/2006/loads/Chapter7_com.pdf
• High-rise building structure -Wolfgang Schueller
• www.greatbuilding.com .
• www.riba.com .