CHILLERS
CATALOGUE
» WE BRING BETTER AIR TO LIFE
A leader in air
technology
solutions with ENVIRONMENT
ECONOMICAL
EXPERTISE
global expertise
85% of the Life Cycle Cost in a ventilation system is generated by the running energy cost. At
Fläkt Woods we are committed to the continuous development of our complete range of Air
Technology products and solutions, providing substantial energy and cost savings. Fläkt Woods is
a global leader with a proven and impressive track record. High-performing components are an
obvious starting point and every 5 minutes we deliver an air treatment, air ventilation or air
diffusion product for complete climate systems all over the world. Reducing the environmental foot
print through innovative products and energy efficient solutions has been at the core of our
business since the start and that mindset is transferred through our unrivalled industry expertise
into every project. Every day.
Nordics
44%
Air Technology
Asia 15% innovation is in
Americas 9%
our roots and we strongly
believe that we are bringing
15 2300 65 Countries
32%
Rest of Europe
FLÄKT WOODS GROUP Worldwide ”Better Air to Life”!
TURNOVER 430M€
Our partners in Europe, the Middle East, US, and Asia include:
end users, contractors, distributors, consultants and engineering firms
Focus Areas
Air Comfort Fire Safety
Every day we consume 1 kg of food and drink 2 Fläkt Woods pioneered air movement in Fire
litres of water, however, we inhale approximately Safety, having built up vast applicational
20 000 litres of air. People deserve a high knowledge through involvement in many major
quality of indoor comfort. Property owners want construction projects. The ability to offer a full
energy efficient, profitable buildings achieving or package of equipment, coupled with our vast
surpassing environmental targets. Our aim is to experience, makes Fläkt Woods the ideal
help you to achieve that. With over 100 years of provider of fire safety solutions.
experience, that is what our customers have All our products are CE marked.
come to expect from us.
UK ChIller
PROJECT APPLICATION
North Staffs Hospital Hospital
Rolls Royce, Heathrow Offices
St. Albums Academy
King Edward School
Circle Health, Reading
Education
Education
Hospital
Project
Harefield Hospital
Gloucester Courts
Westminster Magistrates
Hospital
Public Building
Public Building
References
Blackpool Hospital Hospital
Baxter Foods Factory
Rowley Regis College Education
Burnley Hospital Hospital
Harris Boys Academy Education
Llandudno Theatre Public Building
Sheffield University Education
Middlesbrough College Education
Hexel, Duxford Public Building
Chester Hospital Hospital
One City Square, Leeds Offices
Alderhey Hospital, Liverpool Hospital
Ashford Care Centre Public Building
Assay, Goldsmiths, Birmingham Offices
Salford University Education
Emerson House Offices
Sheffield Hallam University Education
Newcastle University Education
Crossrail Canary Wharf Public Building
Dundee College Education
Evelina Hospital, London Hospital
Freemans Reach HMPO Offices
Goodmans Field, London Public Building
North Ayrshire Hospital Hospital
Inverclyde Hospital Hospital
Edinburgh University, Kelvin Hall Education
Crown House, Worksop Office Offices
Cobalt Offices, Newcastle Offices
Minerva House, Reading Offices
Paisley Hospital, Glasgow Hospital
Aldernmaston, Phoenix Building Public Building
SCRM, Edinburgh Offices
Watson Building, Liverpool Offices
York Art Gallery, York Public Building
1 QC Street Offices
4
CONTENTS
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
5
CONTENTS
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
6
Heat pump Air cooled Outdoor installation R-410A Hermetic Scroll Ice protection system
CAUTION!
A1 For trouble-free operation of the unit it is essential to
A
B2 maintain the safety distances indicated by the green areas.
A2 B
17÷31 C
A1
A
B2
41÷71 A2 B
Size – KCSA 17 21 31 41 51 61 71
A - Length mm 800 800 800 800 800 800 800
B - Width mm 300 300 300 300 300 300 300
C - Height mm 1242 1242 1242 1372 1372 1372 1372
A1 mm 100 100 100 100 100 100 100
A2 mm 500 500 500 500 500 500 500
B2 mm 150 150 150 150 150 150 150
Operating weight kg 75 80 85 105 110 115 120
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
7
TECHNICAL DATA
Size – KCSA 17 21 31 41 51 61 71
Cooling capacity (1) kW 6.50 7.00 8.47 11.3 15.0 17.0 18.8
Sensible capacity (1) kW 5.27 5.52 7.26 8.80 11.7 12.2 15.0
Total power input (1) kW 1.7 1.94 2.32 3.07 4.01 5.27 5.94
EER - 3.44 3.57 3.54 3.64 3.68 3.22 3.21
Heating capacity (2) kW 6.35 6.90 8.47 11.2 15.0 17.2 18.1
Total power input (2) kW 1.65 1.79 2.06 2.84 3.81 4.45 4.66
COP - 3.91 3.91 4.22 3.98 3.99 3.94 3.94
No. of compressors Nr 1 1 1 1 1 1 1
Type of compressors - SCROLL
Standard power supply V 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N
Sound pressure level (3) dB(A) 56 56 57 57 59 59 59
Notes
1. Data referred to coupling with our terminal unit CN-X 17-71 of the same size and in tri-phase versions with compressors
400/3/50+N
2. Internal exchanger air temperature 27°C D.B. 19.5°C W.B. Ambient temperature = 35°C; Total input is obtained from compressor
power input + fan power input
3. Internal exchanger air temperature 20°C; External exchanger air temperature 7 D.B. /6 (°C) W.B. Total input is obtained from
compressor power input + fan power input
4. The sound pressure level refers to a distance of 1m from the outer surface of the unit operating in an open field.
ACCESSORIES
A full list of accessories is available on page 71.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
8
Size – KCSG 8.2 10.2 12.2 16.2 18.2 22.2 26.2 30.2
A - Length mm 1739 1739 1739 1967 1967 1967 2367 2367
B - Width mm 721 721 721 1143 1143 1143 1141 1141
C - Height mm 1287 1287 1287 1599 1599 1599 1593 1593
A1 mm 700 700 700 700 700 700 700 700
A2 mm 700 700 700 700 700 700 700 700
B1 mm 700 700 700 700 700 700 700 700
B2 mm 700 700 700 700 700 700 700 700
Operating weight kg 298 303 323 456 469 490 547 561
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
9
TECHNICAL DATA
Size – KCSG 8.2 10.2 12.2 16.2 18.2 22.2 26.2 30.2
Cooling capacity (1) kW 25.7 31.3 36.0 43.4 51.6 59.1 72.3 80.1
Compressor power input (1) kW 8.79 9.95 12.4 14.1 16.2 20.3 22.6 26.6
Total power input (1) kW 9.20 10.4 12.9 15.6 17.7 21.8 24.2 28.4
EER (1) - 2.78 3.01 2.80 2.78 2.91 2.71 2.99 2.82
Refrigeration circuits Nr 1 1 1 1 1 1 1 1
No. of compressors Nr 2 2 2 2 2 2 2 2
Type of compressors - SCROLL
Standard airflow l/s 2553 2545 2514 4965 4902 4778 7196 6971
Standard power supply V 400/3/50+N
Sound pressure level (2) dB(A) 60 60 60 64 64 65 65 65
Notes
(1) Saturated suction temperature (SST) = 5°C; Outdoor air temperature 35°C
(2) The sound levels refer to the unit at full load, in the rated test conditions.
The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field.
ACCESSORIES
A full list of accessories is available on page 71.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
10
All the units are factory assembled and tested and ready for
operation after connection, with consequent substantial reduction
in installation costs.
FUNCTIONS AND FEATURES
B1 A
B
B2
A1
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
ST - Standard LN - Low Noise
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
11
400T Supply voltage 400/3/50 without neuttral (Standard) - Energy recovery: not required (Standard)
D Partial energy recovery
TECHNICAL DATA
(1) Data referred to following conditions: Saturated suction temperature (SST) = 9.5°C (Dew Point); Outdoor air temperature 35°C
(2) Total absorbed power is given by the compressor absorbed power + fan absorbed power + auxiliary circuit absorbed power.
(3) SCROLL = scroll compressor
(4) The sound levels refer to the unit at full load, in the rated test conditions.
ACCESSORIES
A full list of accessories is available on page 71.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
12
CAUTION!
For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
B1 A2
B A
B2
A1
Size – KCSD 65D 70D 75D 80D 90D 100D 110D 120D 135F 150F 165F 180F
A - Length mm 2950 2950 2950 2950 2950 2950 4250 4250 4250 4250 4250 4250
B - Width mm 2195 2195 2195 2195 2195 2195 2195 2195 2195 2195 2195 2195
C - Height mm 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410
A1 mm 700 700 700 700 700 700 700 700 700 700 700 700
A2 mm 700 700 700 700 700 700 700 700 700 700 700 700
B1 mm 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300
B2 mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
SC Operating weight kg 2102 2164 2226 2288 2293 2298 2926 2984 3113 3120 3506 3670
EN Operating weight kg 2112 2184 2246 2308 2313 2318 2876 3009 3203 3300 3596 3650
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
SC - Compressors soundproofing EN - Super-silenced
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
13
- Energy recovery: not required (Standard) CREFP Device for consumption reduction of the external
D Partial Energy Recovery section at variable speed (phase-cutting) (Standard)
CREFB Device for consumption reduction of the external
section ECOBREEZE fans
ACOUSTIC CONFIGURATION:
SC Acoustic configuration with compressor soundproofing
(Standard)
EN Extremely low noise acoustic configuration
TECHNICAL DATA
Size – KCSD 65D 70D 75D 80D 90D 100D 110D 120D 135F 150F 165F 180F
Cooling capacity (1) kW 210 226 240 255 278 318 364 386 429 462 518 588
Compressor power input kW 56,5 61,2 67,6 73,9 81,2 88,5 99,5 114 124 140 157 172
Total power input (2) kW 64,8 69,5 75,9 82,2 89,5 96,8 112 126 138 156 179 193
EER - 3,25 3,25 3,17 3,10 3,10 3,29 3,25 3,06 3,10 2,95 2,90 3,04
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2
No. of compressors Nr 4 4 4 4 4 4 4 4 6 6 6 6
Type of compressors - SCROLL
Standard power supply V 400/3/50
Sound pressure level (3) dB(A) 76 76 76 76 76 76 78 78 78 78 79 79
Notes
(1) Data referred to the following conditions: Saturated suction temperature (SST) = 9.5°C (Dew Point);
Outdoor air temperature 35°C
(2) Total absorbed power is given by the compressor absorbed power + fan absorbed power + auxiliary circuit absorbed power.
(3) Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. The sound levels refer
to the unit at full load, in the rated test conditions.
The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Data referred to the
following conditions: Saturated suction temperature (SST) = 9.5 °C (Dew Point); Outdoor air temperature 35°C
ACCESSORIES
A full list of accessories is available on page 71.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
14
C
CAUTION!
For trouble-free operation of the unit it is essential to
A maintain the safety distances indicated by the green areas.
1
A
B2
A2
B
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
15
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
PRM Premium
EXC Excellence
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
16
Notes
(*) Data referred to excellence version
(1) User side entering/leaving water temperature 12/7 °C, external exchanger entering air 35°C
ACCESSORIES
A full list of accessories is available on page 71.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
17
Heating only Air cooled Outdoor installation R-407C Hermetic Scroll ELFOControl²
41÷61
A 1
CAUTION!
B2 For trouble-free operation of the unit it is essential to
A
B
maintain the safety distances indicated by the green areas.
C
81
B2 A1
B A
Size – KCDG 41 61 81
A - Length mm 1120 1120 1526
B - Width mm 524 524 557
C - Height mm 1176 1176 1224
A1 mm 150 150 150
B2 mm 500 500 500
Operating weight kg 150 157 266
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
18
TECHNICAL DATA
Size – KCDG 41 61 81
UNIT FOR RADIANT PANELS
A7/W35
Heating capacity kW 14.6 19.2 25.3
Total power input kW 3.76 4.76 6.49
COP (EN 14511:2013) - 3.88 4.04 3.89
COP high efficency option H - 4.10 4.20 4.10
A2/W35
Heating capacity kW 13.0 17.1 22.7
Total power input kW 3.62 4.56 6.26
COP (EN 14511:2013) - 3.59 3.75 3.62
A-5/W35
Heating capacity kW 9.37 12.2 16.0
Total power input kW 3.70 4.69 6.43
COP (EN 14511:2013) - 2.53 2.61 2.48
TERMINAL UNITS
A7/W45
Heating capacity kW 14.8 19.1 26.0
Total power input kW 4.51 5.90 8.30
COP (EN 14511:2013) - 3.28 3.24 3.13
A2/W45
Heating capacity kW 13.2 17.0 23.2
Total power input kW 4.34 5.58 7.91
COP (EN 14511:2013) - 3.04 3.05 2.93
A-5/W45
Heating capacity kW 9.64 12.6 16.7
Total power input kW 4.37 5.63 7.91
COP (EN 14511:2013) - 2.21 2.24 2.11
RADIATORS
A7/W55
Heating capacity kW 15.1 19.0 26.8
Total power input kW 5.27 7.04 10.1
COP (EN 14511:2013) - 2.87 2.70 2.65
A2/W55
Heating capacity kW 13.4 16.9 23.7
Total power input kW 5.06 6.61 9.57
COP (EN 14511:2013) - 2.65 2.56 2.47
A-5/W55
Heating capacity kW 10.0 13.1 17.4
Total power input kW 5.00 6.60 9.40
COP (EN 14511:2013) - 1.97 1.99 1.85
Water flow-rate (User Side) (1) l/s 0.63 0.79 1.06
Useful pump discharge head (1) kPa 43 60 ND
Standard power supply V 230/1/50 400/3/50+N 400/3/50+N
Sound Pressure Level (10m) dB(A) 42 44 48
Min inlet air temperature (W.B.) (2) °C -18 -17 -17
Max. leaving water temperature (3) °C 60 60 60
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
19
Notes
(1) Data referred to the following conditions: Outlet water internal exchanger 45°C; Outdoor air temperature 7°C DB - 6°C WB;
DT=difference between inlet/outlet water temperature=6°C
(2) Water to internal exchanger 49/55°C
(3) Outdoor air temperature: -10°C D.B./ -10.5°C W.B.
ACCESSORIES
A full list of accessories is available on page 71.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
20
Liquid chillers and heat pumps are ideal for the small
scale commercial sector, are specifically designed for outdoor
installation.
Cooling only Heat pump Air cooled Outdoor installation R-410A Hermetic Scroll
(KCAG) (KCBG)
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
21
- Low temperature not required (Standard) - Device for fan consumption reduction of the external
B Water low temperature section: not required (Standard)
CREFB Device for consumption reduction of the external
section ECOBREEZE fans
FREE COOLING (KCAG ONLY):
ENERGY RECOVERY:
- FREE COOLING: not required (Standard)
FCD Direct FREE COOLING - Energy Recovery: not required (Standard)
D Partial energy recovery
TECHNICAL DATA
Size – KCAG 82 102 122 162 182 222 262 302
TERMINAL UNITS
A35/W7
Cooling capacity kW 24.7 28.7 34.2 40.5 46.4 55.2 65.0 73.1
Total power input kW 9.25 10.7 12.8 14.6 17.1 20.8 24.0 27.2
EER (EN 14511:2013) - 2.67 2.67 2.68 2.78 2.72 2.65 2.70 2.69
ESEER - 3.95 3.93 3.88 4.09 3.99 3.90 3.97 3.92
Water flow-rate (User Side) (1) l/s 1.20 1.30 1.60 1.90 2.20 2.60 3.10 3.40
Useful pump discharge head (1) kPa 132 126 120 104 88 148 139 131
Standard power supply V 400/3/50+N
Sound Pressure Level (10m) dB(A) 44 44 44 49 49 50 50 50
Min. entering air temperature (2) °C -10 -10 -10 -10 -10 -10 -10 -10
Max. leaving water temperature °C 18 18 18 18 18 18 18 18
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
22
Notes
(1) Data referred to the following conditions: Internal exchanger water = 12/7°C; Entering external exchanger air temperature 35°C
(2) External exchanger air in quiet
(3) Data referred to the following conditions: Internal exchanger water = 23/18°C;
Entering external exchanger air temperature 35°C
(4) Internal exchanger water = 12/7°C
(5) Exchanger water outlet 35°C
(6) Outlet water internal exchanger 45°C
(7) Room temperature = 7°C (RH = 85%)
ACCESSORIES
A full list of accessories is available on page 72.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
23
Our large water chillers and heat pumps provide the highest
seasonal efficiency. They are designed to be installed outdoor
and feature uneven scroll compressors mounted in the same
circuit, electronic expansion valves and high efficiency plate type
evaporators.
Showcasing an unmatched seasonal efficiency ESEER and is
available in two versions: EXCELLENCE and PREMIUM. The standard
version EXCELLENCE offers the highest efficiency both at full and
at part load. Also the PREMIUM version offers high efficiency at
part load but favour also the compact dimensions being therefore
extremely competitive.
Thanks to its features, we can offer:
SELF-ADAPTABILITY IN DIFFERENT LOAD CONDITIONS, thanks to
the availability of several capacity steps and the adjustment logic
developed for maximum efficiency and minimum wear. FUNCTIONS AND FEATURES
VERY HIGH OVERALL RELIABILITY, thanks to the consolidated
construction choices and the use of industrially-made products
LOWER SOUND EMISSIONS, achieved thanks to the optimal sizing
of the exchange surfaces and the use of high efficiency fans with Cooling only Heat pump Air cooled Outdoor installation R-410A Hermetic Scroll
(KCAJ) (KCBJ)
“winglets”.
QUICK AND EASY installation thanks to the quick connections
with the main circuit, electrical wiring enablement and complete
functional testing before delivery. The units can also be supplied with Ice protection system FREE-COOLING HydroPack ECOBREEZE Electronic expansion
valve
pump assemblies, partial heat recovery and inertial storage tank
already installed on board, bringing together all the system’s main
components in a single solution.
CAUTION!
For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
A2
B1
A
B
B2
A1
Size – KCAJ 352 402 432 452 502 552 602 702 802
SC-EXC A - Length mm 3075 3075 3075 4025 4025 4025 4025 5025 5025
SC-EXC B - Width mm 1097 1097 1097 1097 1097 1097 1097 1097 1097
SC-EXC C - Height mm 1805 1805 1805 1805 1805 1805 1805 1805 1805
SC-EXC A1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000
SC-EXC A2 mm 700 700 700 700 700 700 700 700 700
SC-EXC B1 mm 1350 1350 1350 1350 1350 1350 1350 1350 1350
SC-EXC B2 mm 1350 1350 1350 1350 1350 1350 1350 1350 1350
SC-EXC Operating weight kg 896 933 1024 1207 1234 1256 1302 1497 1544
SC-PRM Operating weight kg 778 802 892 924 963 984 1087 1295 1324
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
24
Size - KCBJ 352 402 432 452 502 552 602 702 802
A - Length mm 3075 3075 3075 3075 3075 4025 4025 5025 5025
B - Width mm 1097 1097 1097 1097 1097 1097 1097 1097 1097
C - Height mm 1805 1805 1805 1805 1805 1805 1805 1805 1805
A1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000
A2 mm 700 700 700 700 700 700 700 700 700
B1 mm 1350 1350 1350 1350 1350 1350 1350 1350 1350
B2 mm 1350 1350 1350 1350 1350 1350 1350 1350 1350
SC Operating weight kg 915 975 1059 1101 1126 1326 1341 1549 1564
EN Operating weight kg 915 975 1059 1101 1126 1326 1341 1549 1564
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
SC-EXC Compressors soundproofing (SC)-Excellence SC Compressors soundproofing (SC)
TECHNICAL DATA
Size – KCAJ 352 402 432 452 502 552 602 702 802
SC-EXC Cooling
capacity (EN14511:2013) (1) kW 95.6 109 120 129 140 152 174 195 216
SC-EXC Total power input (EN14511:2013) (1) kW 30.6 34.8 38.8 40.9 45.0 49.0 55.8 62.3 69.6
SC-EXC EER (EN 14511:2013) (1) - 3.12 3.13 3.10 3.15 3.12 3.10 3.12 3.13 3.11
SC-EXC ESEER (1) - 4.22 4.30 4.22 4.21 4.24 4.26 4.16 4.32 4.10
SC-PRM Cooling capacity (EN14511:2013) (1) kW 89.7 101 111 119 130 143 159 185 203
SC-PRM Total power input (EN14511:2013) (1) kW 32.6 37.7 42.0 44.2 48.0 53.2 61.0 66.9 75.9
SC-PRM EER (EN 14511:2013) (1) - 2.75 2.67 2.64 2.70 2.71 2.69 2.61 2.76 2.67
SC-PRM ESEER (1) - 3.91 3.95 3.90 4.03 4.02 3.99 3.90 3.99 3.79
SC-EXC Sound pressure level (2) dB(A) 67 67 68 68 68 69 69 70 70
SC-PRM Sound pressure level (2) dB(A) 67 67 67 67 68 68 68 69 69
Refrigeration circuits Nr 1 1 1 1 1 1 1 1 1
No. of compressors Nr 2 2 2 2 2 2 2 2 2
Type of compressors - SCROLL
Standard power supply V 400/3/50
Size – KCBJ 352 402 432 452 502 552 602 702 802
SC
Cooling capacity (EN14511:2013) (1) kW 84.4 96.7 105 114 122 140 156 183 202
SC Total power input (EN14511:2013) (1) kW 32.7 36.5 41.3 43.6 48.5 51.3 60.8 66.9 76.5
SC EER (EN 14511:2013) (1) - 2.58 2.65 2.55 2.61 2.52 2.73 2.56 2.73 2.64
SC ESEER (1) - 3.43 3.56 3.54 3.54 3.56 3.49 3.40 3.35 3.31
SC
Heating capacity (EN14511:2013) (3) kW 100 116 127 136 147 165 183 212 234
SC Total power input (EN14511:2013) (3) kW 32.6 36.7 40.4 42.1 45.8 51.0 57.1 65.3 72.6
SC COP (EN 14511:2013) (3) - 3.08 3.16 3.14 3.23 3.20 3.24 3.21 3.25 3.23
SC Refrigeration circuits Nr 1 1 1 1 1 1 1 1 1
SC No. of compressors Nr 2 2 2 2 2 2 2 2 2
SC Type of compressors - SCROLL
SC Standard power supply V 400/3/50
SC Sound pressure level (2) dB(A) 67 67 67 67 67 68 68 71 71
EN Sound pressure level (2) dB(A) 62 63 64 64 64 65 65 66 66
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
25
Notes
(1) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: Internal exchanger water
temperature = 12/7°C; entering external exchanger air temperature = 35°C
(2) The sound levels refer to the unit at full load, in the rated test conditions.
The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Measures
according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. Data referred to the following
conditions: Internal exchanger water = 12/7°C; Outdoor air temperature 35°C
(3) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: Internal exchanger water
temperature = 40/45°C. External exchanger air temperature 7 D.B. /6 (°C) W.B.
SC-EXC Compressors soundproofing (SC)-Excellence
SC-PRM Compressors soundproofing (SC)-Premium
SC Compressors soundproofing (SC)
EN Super-silenced (EN)
ACCESSORIES
A full list of accessories is available on page 72.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
26
Heat pump Air cooled Outdoor installation R-407C Hermetic Scroll ELFOControl²
CAUTION!
For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
A2
B1
B A
B2
A1
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
27
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
28
Notes
(1) COP (EN 14511:2008) performance coefficient in heating mode. Ratio between heating capacity supplied and absorbed power
in accordance with EN 14511:2008. The absorbed power is the sum of the power absorbed by the compressor + electric
auxiliary circuit + percentage of power absorbed by the pump to prevent pressure drops inside the unit
(2) Data refer to the following conditions: internal water exchanger = 12/7°C; outdoor air temperature 35°C
ACCESSORIES
A full list of accessories is available on page 72.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
29
The KCAP / KCBP heat pumps and liquid chillers are high efficiency
packaged units for small and medium-sized applications in the
services sector. Designed for outdoor installation, they ensure the
highest energy efficiency over the entire operating cycle, especially
under load staging conditions that coincide with the unit’s longer
operating time, thanks to the continuous capacity modulation that
adapts the capacity supplied to the actual energy demand required
by the system.
Available in the EXCELLENCE version offering the highest energy
efficiency both during the seasonal cycle and under full load
conditions.
Benefits:
HIGH UNIT RELIABILITY, thanks to the double refrigerant circuit, to
the proven architecture and to the components produced at high
volumes.
FUNCTIONS AND FEATURES
ADVANCED TECHNOLOGY: The modulating pumping unit consisting
of two parallel pumps controlled by an inverter, allows for lower
consumption and at the same time ensures operation even under
critical conditions. It automatically reduces the water flow rate
according to the load required by the system, by controlling the Cooling only Heat pump Air cooled Outdoor installation R-410A Hermetic Scroll
(WSAT-XIN) (WSAN-XIN)
temperature, and prevents blocks due to overloads in the event of
critical conditions.
MODULARITY AND MANAGEMENT OF MORE UNITS IN CASCADE: The
compact construction allows to combine multiple units in confined
AxiTop Vary Flow Full Inverter DC
spaces, offering a high power system. The control allows to
coordinate up to 7 units managing automatically the operation with
maximum efficiency.
CAUTION!
For trouble-free operation of the unit it is essential to
A1
maintain the safety distances indicated by the green areas.
A
B2
B
A2
B1
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
30
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
(*) PRELIMINARY DATA
TECHNICAL DATA
Size – KCAP 18.2 20.2 25.2 30.2 35.2* 40.2* 45.2*
Cooling capacity (EN14511:2013) (1) kW 50.1 62.7 74.3 86.3 99.3 112 126
Total power input (EN14511:2013) (1) kW 16.1 20.2 23.9 27.6 31.9 36.1 40.5
EER (EN 14511:2013) (1) - 3.12 3.10 3.11 3.13 3.11 3.10 3.12
ESEER (1) - 4.10 4.05 4.03 4.04 4.08 4.06 4.03
Refrigeration circuits Nr 2 2 2 2 2 2 2
No. of compressors Nr 2 2 2 2 2 2 2
Type of compressors - INVERTER + ON/OFF SCROLL
Standard power supply V 400/3/50+N
Sound pressure level dB(A) 65 65 66 66 70 70 71
(1) Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature =
12/7°C - Entering external exchanger air temperature = 35°C
(2) Data calculated in compliance with Standard UNI-EN14511:2013 referred to the following conditions:Internal exchanger water
temperature = 40/45°C, entering external exchanger air temperature = 7°C D.B. / 6°C W.B.
ACCESSORIES
A full list of accessories is available on page 73.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
31
The KCCR / KCDR heat pumps and liquid chillers are high efficiency
packaged units for small and medium-sized applications in the
services sector. Designed for outdoor installation, they ensure the
highest energy efficiency over the entire operating cycle, especially
under load staging conditions that coincide with the unit’s longer
operating time, thanks to the modular scroll technology that adapts
the capacity supplied to the actual energy demand required by the
system.
Available in the two EXCELLENCE and PREMIUM versions. The
EXCELLENCE version offers the highest energy efficiency both during
the seasonal cycle and under full load conditions. The PREMIUM
version provides excellent performance under partial load conditions,
but has a compact design which gives it an additional competitive
edge.
Benefits:
HIGH UNIT RELIABILITY, thanks to the double refrigerant circuit, to the FUNCTIONS AND FEATURES
proven architecture and to the components produced at high volumes.
ADVANCED TECHNOLOGY: The modulating pumping unit consisting
of two parallel pumps controlled by an inverter, allows for lower
consumption and at the same time ensures operation even under
Cooling only Heat pump Air cooled Outdoor installation R-410A Hermetic Scroll
critical conditions. It automatically reduces the water flow rate (KCCR) (KCDR)
CAUTION!
For trouble-free operation of the unit it is essential to
A2 maintain the safety distances indicated by the green areas.
B1
B A
B2
A1
Size – KCCR 50.4 55.4 60.4 65.4 70.4 80.4 90.4 100.4 110.4 120.4
A - Length mm 4200 4200 4200 4200 4400 4400 4400 5200 5200 5200
B - Width mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250
C - Height mm 1655 1655 1655 1655 2300 2300 2300 2300 2300 2300
A1 mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
A2 mm 750 750 750 750 750 750 750 750 750 750
B1 mm 1100 1100 1100 1500 1500 1500 1500 1500 1500 1500
B2 mm 1100 1100 1100 1500 1500 1500 1500 1500 1500 1500
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
32
Size – KCDR 50.4 55.4 60.4 65.4 70.4 80.4 90.4 100.4 110.4 120.4
A - Length mm 4200 4200 4200 4200 4400 4400 4400 5200 5200 5200
B - Width mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250
C - Height mm 1655 1655 1655 1655 2300 2300 2300 2300 2300 2300
A1 mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
A2 mm 750 750 750 750 750 750 750 750 750 750
B1 mm 1100 1100 1100 1500 1500 1500 1500 1500 1500 1500
B2 mm 1100 1100 1100 1500 1500 1500 1500 1500 1500 1500
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
PRELIMINARY DATA
TECHNICAL DATA
Size – KCCR 50.4 55.4 60.4 65.4 70.4 80.4 90.4 100.4 110.4 120.4
Cooling capacity (EN14511:2013) (1) kW 150 160 172 183 198 225 253 295 319 347
Total power input (EN14511:2013) (1) kW 47.9 51.6 55.3 59.1 63.6 72.3 81.6 94.9 102 112
EER (EN 14511:2013) (1) - 3.13 3.11 3.12 3.10 3.12 3.11 3.10 3.11 3.12 3.10
ESEER (1) - 4.21 4.23 4.20 4.22 4.19 4.22 4.24 4.28 4.26 4.26
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2
No. of compressors Nr 4 4 4 4 4 4 4 4 4 4
Type of compressors - ON/OFF SCROLL
Standard power supply V 400/3/50+N
Size – KCDR 50.4 55.4 60.4 65.4 70.4 80.4 90.4 100.4 110.4 120.4
Cooling capacity (EN14511:2013) (1) kW 139 149 160 170 184 208 234 273 296 321
Total power input (EN14511:2013) (1) kW 48.7 53.6 58.3 63.8 67.5 77.1 92.6 98.0 110 126
EER (EN 14511:2013) (1) - 2.85 2.77 2.74 2.66 2.72 2.70 2.53 2.79 2.69 2.55
ESEER (1) - 4.06 3.98 4.01 4.03 4.01 4.04 4.02 4.02 4.04 4.01
Heating capacity (EN14511:2013) (2) kW 155 167 183 193 209 239 273 315 340 380
Total power input (EN14511:2013) (2) kW 47.9 52.1 56.5 60.1 65.3 74.3 85.1 97.5 106 118
COP (EN 14511:2013) (2) - 3.23 3.21 3.24 3.21 3.20 3.22 3.20 3.23 3.22 3.21
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2
No. of compressors Nr 4 4 4 4 4 4 4 4 4 4
Type of compressors - ON/OFF SCROLL
Standard power supply V 400/3/50+N
Notes
(1) Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature =
12/7°C - Entering external exchanger air temperature = 35°C
(2) Data calculated in compliance with Standard UNI-EN14511:2013 referred to the following conditions:Internal exchanger water
temperature = 40/45°C, entering external exchanger air temperature = 7°C D.B. / 6°C W.B.
PRELIMINARY DATA
ACCESSORIES
A full list of accessories is available on page 73.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
33
CAUTION!
For trouble-free operation of the unit it is essential to
A1
maintain the safety distances indicated by the green areas.
A
B2
B
A2
B1
Size – KCCP 18.2 20.2 25.2 30.2 35.2* 40.2* 45.2*
A - Length mm 2400 2400 2400 2400 3540 3540 3540
B - Width mm 1100 1100 1100 1100 1500 1500 1500
C - Height mm 1540 1540 1790 1790 1655 1655 1655
A1 mm 800 800 800 800 1500 1500 1500
A2 mm 800 800 800 800 750 750 750
B1 mm 800 800 800 800 1100 1100 1100
B2 mm 800 800 800 800 1100 1100 1100
Operating weight kg 650 660 720 755 1270 1300 1340
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative. (*) PRELIMINARY DATA
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
34
- Energy recovery: not required (Standard) 4T Configuration for 4-pipe system (Standard)
D Partial energy recovery 2T Configuration for 2-pipe system
Refrigeration circuits Nr 2 2 2 2 2 2 2
No. of compressors Nr 2 2 2 2 2 2 2
Type of compressors - INVERTER + ON/OFF SCROLL
Standard power supply V 400/3/50+N
Sound pressure level dB(A) 65 65 66 66 70 70 71
Notes
(1) Data refer to the following conditions: internal water exchanger = 40/45°C; outdoor air temperature 7°C D.B. / 6°C W.B.
(2) Data refer to the following conditions: internal water exchanger = 12/7 °C; outdoor air temperature 35°C
(3) Data referred to the following conditions: - internal exchanger water (evaporator) = 12/7°C - external exchanger water
(condenser) = 40/45°C
(4) Overall efficiency = (Cooling capacity + Heating capacity) / (Total power input) (*) PRELIMINARY DATA
ACCESSORIES
A full list of accessories is available on page 73.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
35
CAUTION!
For trouble-free operation of the unit it is essential to
A2
B1 maintain the safety distances indicated by the green areas.
B A
B2
A1
Size – KCER 50.4 55.4 60.4 65.4 70.4 80.4 90.4 100.4 110.4 120.4
A - Length mm 4240 4240 4240 4240 4440 4440 4440 5240 5240 5240
B - Width mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250
C - Height mm 1655 1655 1655 1655 2300 2300 2300 2300 2300 2300
A1 mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
A2 mm 750 750 750 750 750 750 750 750 750 750
B1 mm 1100 1100 1100 1500 1500 1500 1500 1500 1500 1500
B2 mm 1100 1100 1100 1500 1500 1500 1500 1500 1500 1500
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative. (*) PRELIMINARY DATA
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
36
TECHNICAL DATA
Size – KCER 50.4 55.4 60.4 65.4 70.4 80.4 90.4 100.4 110.4 120.4
COOLING 0% - HEATING 100%
Heating capacity (1) kW 156 169 185 195 211 242 276 319 344 384
Total power input (1) kW 46.1 50.2 54.5 57.9 62.9 71.6 82.0 93.9 102 114
COP at full load (1) - 3.39 3.37 3.40 3.37 3.36 3.38 3.36 3.39 3.38 3.37
COOLING 100% - HEATING 0%
Cooling capacity (2) kW 139 149 160 170 184 209 235 274 297 323
Total power input (2) kW 48.1 53.0 57.6 63.0 66.7 76.2 91.5 96.8 109 125
EER at full load (2) - 2.90 2.81 2.78 2.70 2.76 2.74 2.57 2.83 2.73 2.59
COOLING 100% - HEATING 100%
Cooling capacity (3) kW 141 151 162 172 187 212 238 278 300 326
Heating capacity (3) kW 180 194 213 224 243 278 317 367 396 442
Total power input (3) kW 41.1 44.7 48.5 51.5 56.0 63.7 73.0 83.6 90.7 102
Overall efficiency (4) - 7.81 7.73 7.74 7.70 7.68 7.68 7.61 7.71 7.68 7.56
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2
No. of compressors Nr 4 4 4 4 4 4 4 4 4 4
Type of compressors - ON/OFF SCROLL
Standard power supply V 400/3/50+N
Notes
(1) Data refer to the following conditions: internal water exchanger = 40/45°C; outdoor air temperature 7°C D.B. / 6°C W.B.
(2) Data refer to the following conditions: internal water exchanger = 12/7 °C; outdoor air temperature 35°C
(3) Data referred to the following conditions: - internal exchanger water (evaporator) = 12/7°C - external exchanger water
(condenser) = 40/45°C
(4) Overall efficiency = (Cooling capacity + Heating capacity) / (Total power input) (*) PRELIMINARY DATA
ACCESSORIES
A full list of accessories is available on page 73.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
37
C
CAUTION!
For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
A2
B1
A
B
B2 A1
Size – KCCC 200H 220H 230H 240H 270J 300L 315L 330L 345L 360L
ST/SC A - Length mm 4750 4750 4750 4750 5708 6658 6658 6658 7608 7608
ST/SC B - Width mm 2233 2233 2233 2233 2233 2233 2233 2233 2233 2233
ST/SC C - Height mm 2250 2250 2250 2250 2280 2280 2280 2280 2280 2280
ST/SC A1 mm 1930 1930 1930 1930 1690 1690 1690 1690 1690 1690
ST/SC A2 mm 1700 1700 1700 1700 1700 1700 1700 1700 1700 1700
ST/SC B1 mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
ST/SC B2 mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
ST Operating weight kg 3887 4118 4360 4374 5358 6023 6080 6114 6511 6567
SC Operating weight kg 4038 4268 4510 4524 5570 6266 6324 6357 6745 6800
EN Operating weight kg 4038 4268 4510 4524 5570 6266 6324 6357 6745 6800
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative. (*) PRELIMINARY DATA
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
38
TECHNICAL DATA
Size – KCCC 200H 220H 230H 240H 270J 300L 315L 330L 345L 360L
ST/SC Cooling
capacity (EN14511:2013) (1) kW 509 556 609 647 692 748 797 860 910 965
ST/SC Total power input (EN14511:2013) (1) kW 185 204 220 235 251 273 289 310 328 349
ST/SC EER (EN 14511:2013) (1) - 2.73 2.69 2.73 2.71 2.71 2.70 2.71 2.73 2.73 2.72
ST/SC ESEER (1) - 4.24 4.17 4.46 4.43 4.51 4.58 4.60 4.64 4.64 4.62
ST/SC Refrigeration circuits Nr 4 4 4 4 4 4 4 4 4 4
ST/SC No. of compressors Nr 8 8 8 8 10 12 12 12 12 12
ST/SC Type of compressors - SCROLL
EN
Cooling capacity (EN14511:2013) (1) kW 491 533 573 609 658 714 754 810 854 916
EN Total power input (EN14511:2013) (1) kW 193 211 229 246 259 283 300 322 339 360
EN EER (EN 14511:2013) (1) - 2.54 2.52 2.50 2.48 2.54 2.52 2.51 2.52 2.52 2.54
EN ESEER (1) - 4.32 4.24 4.23 4.21 4.38 4.40 4.41 4.42 4.42 4.46
EN Refrigeration circuits Nr 4 4 4 4 4 4 4 4 4 4
EN No. of compressors Nr 8 8 8 8 10 12 12 12 12 12
EN Type of compressors - SCROLL
ST Sound pressure level (2) dB(A) 80 80 80 81 81 81 81 82 82 82
SC Sound pressure level (2) dB(A) 75 76 76 77 77 78 78 78 79 79
EN Sound pressure level (2) dB(A) 70 71 71 71 71 72 72 73 73 73
Notes
(1) Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature =
12/7°C - Entering external exchanger air temperature = 35°C
(2) Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. The sound levels refer
to the unit at full load, in the rated test conditions.
The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Data referred to
the following conditions: Internal exchanger water = 12/7°C; Outdoor air temperature 35°C; The sound levels EN version is valid within
the operating range relative to these acoustic versions; make reference to the noise data relative to SC version for higher outdoor air
temperatures and in any case included within the operation limits of SC version.
ST Standard (ST)
SC Compressors insulation (SC)
EN Super-silenced (EN)
ACCESSORIES
A full list of accessories is available on page 74.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
39
energy recovery.
INDUSTRIALISED SYSTEM - The units can be installed easily and
quickly thanks to the quick connections towards the user circuit, to Hermetic Scroll HydroPack AxiTop Electronic expansion
the fact that they are already set up for electrical connections and (sizes 120.4÷240.4) valve
thanks to the full operating test before shipping. They can also be
provided with pumping units already installed, thereby integrating all
the main components of the system in a single solution.
B1
A2
CAUTION!
B
A
For trouble-free operation of the unit it is essential to
90.4 ÷ B2
240.4 1
A
C maintain the safety distances indicated by the green areas.
A2
B1
A
B
260.8
÷ 480. B2
8
A1
Size – KCCK 90.4 100.4 110.4 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.8 280.8 300.8 320.8 340.8 360.8 400.8 440.8 480.8
SC-EXC A - Length mm 4151 4151 4151 4151 5126 5126 5126 5995 5995 5995 9317 10294 10294 10294 10294 10294 12122 12122 12122
SC-EXC B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
SC-EXC C - Height mm 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668
SC-EXC A1 mm 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535
SC-EXC A2 mm 700 700 700 700 700 700 700 700 700 700 1535 1535 1535 1535 1535 1535 1535 1535 1535
SC-EXC B1 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
SC-EXC B2 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
40
Size – KCCK 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.6 280.6 300.6 320.6 340.6 360.6 400.8 440.8 480.8
SC-PRM A - Length mm 4151 4151 4151 5126 5126 5995 5995 8342 8342 8342 8342 9317 10294 10294 12122 12122
SC-PRM B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
SC-PRM C - Height mm 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668
SC-PRM A1 mm 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535
SC-PRM A2 mm 700 700 700 700 700 700 700 1535 1535 1535 1535 1535 1535 1535 1535 1535
SC-PRM B1 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
SC-PRM B2 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
Size - KCDK 90.4 100.4 110.4 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.8 280.8 300.8 320.8 340.8 360.8 400.8 440.8 480.8
A - Length mm 4151 4151 4151 4151 5126 5126 5995 5995 5995 5995 9317 10294 10294 10294 11215 12122 12122 12122 12122
B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
C - Height mm 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668
A1 mm 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535
A2 mm 700 700 700 700 700 700 700 700 700 700 1535 1535 1535 1535 1535 1535 1535 1535 1535
B1 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
B2 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
SC-EXC: Compressors soundproofing (SC)-Excellence
SC-PRM: Compressors soundproofing (SC)-Premium
- Double set point: not required (Standard) SC Acoustic configuration with compressor soundproofing
DSP Double set point (Standard)
EN Extremely low noise acoustic configuration
ENERGY RECOVERY:
- Energy recovery: not required (Standard) VERSION:
D Partial energy recovery EXC Excellence (Standard)
R Total energy recovery PRM Premium (KCCK only) (sizes 120.4 - 240.4)
LOW TEMPERATURE:
- Low temperature: not required (Standard)
B Water low temperature
Size – KCCK 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.6 280.6 300.6 320.6 340.6 360.6 400.8 440.8 480.8
SC-PRM Cooling
capacity (EN14511:2013) (1) kW 333 379 421 490 529 594 645 691 735 776 817 884 951 1058 1188 1290
SC-PRM Total power input (EN14511:2013) (1) kW 120 136 151 174 189 211 229 251 267 281 296 319 341 378 422 458
SC-PRM EER (EN 14511:2013) (1) - 2.78 2.79 2.79 2.82 2.80 2.82 2.82 2.75 2.76 2.76 2.76 2.77 2.79 2.80 2.82 2.82
SC-PRM ESEER (1) - 4.11 4.15 4.12 4.12 4.06 4.12 4.10 4.22 4.25 4.23 4.21 4.20 4.22 4.16 4.22 4.20
SC-PRM Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4
SC-PRM No. of compressors Nr 4 4 4 4 4 4 4 6 6 6 6 6 6 8 8 8
SC-PRM Type of compressors - SCROLL
SC-PRM Standard power supply V 400/3~/50
SC-PRM Sound pressure level (2) dB(A) 72 72 73 75 75 74 74 75 75 75 76 77 78 78 77 77
EN-PRM Sound pressure level (2) dB(A) 66 66 67 69 69 69 69 69 69 69 70 71 72 72 72 72
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
41
Notes
(1) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: Internal exchanger water
temperature = 12/7°C; Entering eExternal exchanger air temperature = 35°C
(2) Sound levels refer to full load units, in test nominal conditions. The sound pressure level refers to 1 m. from the standard unit
outer surface operating in open field. Measurements are carried out according to the UNI EN ISO 9614-2 standard, in
compliance with the EUROVENT 8/1 certification. Data refer to the following conditions: internal water exchanger = 12/7 °C;
outdoor air temperature 35°C
(3) Sound levels refer to full load units, in test nominal conditions. The sound pressure level refers to 1 m. from the standard unit
outer surface operating in open field. Measurements are carried out according to the UNI EN ISO 9614-2 standard, in
compliance with the EUROVENT 8/1 certification. Data refer to the following conditions: internal water exchanger =
12/7 °C; outdoor air temperature 35°C; The indicated sound levels are only valid within the operating field of the unit in the
“Supersilenced EN” configuration; with outdoor air temperatures which are higher and in any case within the operating field of
the “Soundproofed Compressors SC” configuration bearing in mind the sound levels of the unit in the “Soundproofed
Compressors SC” configuration.
(4) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: Internal exchanger water
temperature = 40/45°C. Entering external exchanger air temperature = 7°C D.B./6°C W.B.
ACCESSORIES
A full list of accessories is available on page 74.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
42
CAUTION!
For trouble-free operation of the unit it is essential to
B1
2
B
A
maintain the safety distances indicated by the green areas.
A
90.4 ÷ B2
240.4
A1
C
A2
B1
A
B
260.8
÷ 480. B2
8
A1
Size - KCEK 90.4 100.4 110.4 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.8 280.8 300.8 320.8 340.8 360.8 400.8 440.8 480.8
A - Length mm 4151 4151 4151 4151 5126 5126 5995 5995 5995 5995 9317 10294 10294 10294 11215 12122 12122 12122 12122
B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
C - Height mm 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668
A1 mm 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535
A2 mm 700 700 700 700 700 700 700 700 700 700 1535 1535 1535 1535 1535 1535 1535 1535 1535
B1 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
B2 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
43
- Double set point: not required (Standard) SC Acoustic configuration with compressor soundproofing
DSP Double set point (Standard)
EN Extremely low noise acoustic configuration
ENERGY RECOVERY:
R Total energy recovery VERSION:
EXC Excellence (Standard)
LOW TEMPERATURE:
- Low temperature: not required (Standard) CONFIGURATION:
B Water low temperature 4T Configuration for 4 pipe system (Standard)
2T Configuration for 2 pipe system
TECHNICAL DATA
Size – KCEK 90.4 100.4 110.4 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.8 280.8 300.8 320.8 340.8 360.8 400.8 440.8 480.8
COOLING 100%
SC-4T Cooling
capacity (1) kW 258 274 297 339 383 433 502 543 600 648 722 766 816 866 935 1004 1086 1200 1296
SC-4T Total power input (1) kW 88.8 96.1 105 119 137 151 175 189 206 227 256 274 288 302 326 350 378 412 454
SC-4T EER (1) - 2.91 2.85 2.83 2.85 2.80 2.87 2.87 2.87 2.91 2.85 2.82 2.80 2.83 2.87 2.87 2.87 2.87 2.91 2.85
HEATING 100%
SC-4T Heating
capacity (2) kW 296 327 356 397 446 494 568 629 677 731 843 892 940 988 1062 1136 1258 1354 1462
SC-4T Total power input (2) kW 82.9 90.8 98 108 122 135 157 173 189 203 230 244 257 270 292 314 346 378 406
SC-4T COP (2) - 3.57 3.60 3.63 3.68 3.66 3.66 3.62 3.64 3.58 3.60 3.67 3.66 3.66 3.66 3.64 3.62 3.64 3.58 3.60
COOLING 100% - HEATING 100%
SC-4T Cooling
capacity (3) kW 255 275 305 344 397 442 509 556 612 670 741 794 839 884 951 1018 1112 1224 1340
SC-4T Heating
capacity (3) kW 331 357 396 447 513 573 658 720 794 866 960 1026 1086 1146 1231 1316 1440 1588 1732
SC-4T Total power input (3) kW 76.6 82.6 91.2 103 117 132 150 164 183 197 220 234 249 264 282 300 328 366 394
SC-4T Overall efficiency (4) - 7.65 7.65 7.69 7.68 7.78 7.69 7.78 7.78 7.687.80 7.73 7.78 7.73 7.69 7.74 7.78 7.78 7.68 7.80
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4
No. of compressors Nr 4 4 4 4 4 4 4 4 4 4 8 8 8 8 8 8 8 8 8
Type of compressors - SCROLL
Standard power supply V 400/3~/50
Notes
(1) Data refer to the following conditions: internal water exchanger = 12/7°C; outdoor air temperature 35°C
(2) Data referred to the following conditions: internal exchanger water = 40/45°C.
External exchanger air temperature 7 D.B. /6°C W.B.
(3) Data refer to the following conditions: internal water exchanger = 12/7°C; outdoor air temperature 40/45°C
(4) Overall efficiency = (Heating capacity + Heating capacity) / (Total power input)
PRELIMINARY DATA
ACCESSORIES
A full list of accessories is available on page 75.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
44
CAUTION!
B1
For trouble-free operation of the unit it is essential to
A2
B
A maintain the safety distances indicated by the green areas.
90.4 ÷ B2
240.4
A1
C
A2
B1
A
B
260.8
÷ 480. B2
8
A1
Size - KCFK 90.4 100.4 110.4 120.4 140.4 160.4 180.4 200.4 220.4 240.4 260.8 280.8 320.8 360.8 400.8 440.8 480.8
SC A - Length mm 4110 4110 4110 4110 5085 5085 5085 6060 6060 6060 9195 10170 10170 10170 12120 12120 12120
SC B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
SC C - Height mm 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673
SC A1 mm 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690
SC A2 mm 750 750 750 750 750 750 750 750 750 750 1690 1690 1690 1690 1690 1690 1690
SC B1 mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
SC B2 mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
SC: Acoustic configuration with compressor soundproofing
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
45
- Double set point: not required (Standard) SC Acoustic configuration with compressor soundproofing
DSP Double set point (Standard)
DSPB Double set point for water low temperature EN Extremely low noise acoustic configuration
FREE COOLING:
LOW TEMPERATURE:
FDC Direct FREE COOLING (Standard)
- Low temperature: not required (Standard)
FCI Direct FREE COOLING
B Water low temperature
VERSION:
EXC Excellence (Standard)
TECHNICAL DATA
Size – KCFK 90.4 100.4 110.4 120.4 140.4 160.4 180.4 200.4 220.4 240.4
FREE-COOLING OFF
SC Cooling
capacity (1) kW 293 318 347 387 444 503 563 627 681 740
SC Total power input (1) kW 84 91 100 111 128 142 162 177 196 213
SC EER (1) - 3.48 3.49 3.47 3.47 3.48 3.53 3.47 3.54 3.47 3.48
FREE-COOLING
SC Cooling
capacity (2) kW 206 223 231 236 330 335 344 445 449 458
SC Total power input (2) kW 9.28 9.35 9.35 9.58 12.5 12.8 13.0 16.0 16.1 16.2
SC EER (2) - 22.2 23.9 24.7 24.7 26.4 26.3 26.5 27.9 27.9 28.3
SC Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2
SC No. of compressors Nr 4 4 4 4 4 4 4 4 4 4
SC Type of compressors - SCROLL
SC Standard power supply V 400/3~/50
Notes
(1) Data referred to the following conditions: internal exchanger water = 15/10°C; glycol 30% entering external exchanger air
temperature 30°C
(2) Internal exchanger water temperature = 15 / 10°C;
External exchanger entering air temperature = 2°C D.B. / 1°C W.B.; Glycol 30%
PRELIMINARY DATA
ACCESSORIES
A full list of accessories is available on page 75.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
46
maintenance costs.
CAUTION!
For trouble-free operation of the unit it is essential to
C
maintain the safety distances indicated by the green areas.
B1
A2
B
A
B2
A1
Size – KCCM 200.2 210.2 220.2 240.2 260.2 280.2 320.2 340.2 360.2 400.2 440.2 500.2 540.2 580.2
ST-EXC A - Length mm 4788 4788 5758 5758 5758 6738 6738 7714 7714 8691 8691 10640 10640 10640
ST-EXC B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
ST-EXC C - Height mm 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668
ST-EXC A1 mm 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535
ST-EXC A2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
ST-EXC B1 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
ST-EXC B2 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
ST-PRM A - Length mm 4788 4788 4788 4788 4788 5758 5758 6738 6738 6738 7714 7714 8691 8691
ST-PRM B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
ST-PRM C - Height mm 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668 2668
ST-PRM A1 mm 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535 1535
ST-PRM A2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
ST-PRM B1 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
ST-PRM B2 mm 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
ST-EXC Operating weight kg 4717 4715 5401 5454 5565 6088 6282 7055 7435 8013 8165 8527 8930 9160
ST-PRM Operating weight kg 4617 4643 4669 4799 4903 5612 5712 6442 6651 6854 7701 7911 8293 8467
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
ST-EXC: Standard (ST)-Excellence ST-PRM: Standard (ST)-Premium
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
47
LOW TEMPERATURE:
ENERGY RECOVERY:
- Low temperature: not required (Standard)
B Water low temperature - Energy recovery: not required (Standard)
D Partial energy recovery
R Total energy recovery
VERSION:
EXC Excellence (Standard)
PRM Premium
TECHNICAL DATA
Size – KCCM 200.2 210.2 220.2 240.2 260.2 280.2 320.2 340.2 360.2 400.2 440.2 500.2 540.2 580.2
ST/SC-EXC Cooling
capacity (EN14511:2013) (1) kW 484 508 549 583 635 706 780 835 898 977 1096 1213 1315 1423
ST/SC-EXC Total power input (EN14511:2013) (1) kW 156 164 175 186 204 226 247 267 287 313 353 388 424 454
ST/SC-EXC EER (EN 14511:2013) (1) - 3.10 3.10 3.14 3.14 3.11 3.13 3.16 3.13 3.13 3.12 3.10 3.13 3.10 3.13
ST/SC-EXC ESEER (1) - 4.00 4.00 4.05 4.06 4.01 4.03 4.07 4.03 4.04 4.02 4.00 4.03 4.00 4.04
ST/SC-EXC Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/SC-EXC No. of compressors Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/SC-EXC Type of compressors (2) - DSW
ST/SC-EXC Standard power supply V 400/3~/50
ST/SC-PRM Cooling
capacity (EN14511:2013) (1) kW 467 489 512 558 599 666 741 781 833 912 1024 1139 1255 1353
ST/SC-PRM Total power input (EN14511:2013) (1) kW 162 172 182 195 215 243 264 284 309 337 379 416 463 482
ST/SC-PRM EER (EN 14511:2013) (1) - 2.89 2.84 2.81 2.86 2.79 2.74 2.80 2.75 2.70 2.70 2.70 2.74 2.71 2.81
ST/SC-PRM ESEER (1) - 3.93 3.86 3.82 3.89 3.79 3.73 3.81 3.74 3.67 3.68 3.67 3.73 3.68 3.82
ST/SC-PRM Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/SC-PRM No. of compressors Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/SC-PRM Type of compressors (2) - DSW
ST/SC-PRM Standard power supply V 400/3~/50
ST-EXC Sound pressure level (3) dB(A) 81 81 81 81 80 80 80 81 82 83 85 86 87 87
ST-PRM Sound pressure level (3) dB(A) 81 81 80 81 80 80 80 81 82 83 85 85 87 87
SC-EXC Sound pressure level (3) dB(A) 77 77 77 77 77 77 77 78 79 80 82 82 83 83
SC-PRM Sound pressure level (3) dB(A) 77 77 77 77 77 77 77 78 79 80 82 82 83 83
Notes
(1) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: Internal exchanger water =
12/7°C; External exchanger entering air = 35°C
(2) DSW = twin-screw compressor
(3) Sound levels refer to full load units, in test nominal conditions. The sound pressure level refers to 1 m. from the standard unit
outer surface operating in open field. Measurements are carried out according to the UNI EN ISO 9614-2 standard, in
compliance with the EUROVENT 8/1 certification. Data referred to the following conditions: Internal exchanger water = 12/7°C;
Entering external exchanger air temperature 35°C
SC-EXC Compressors insulation (SC)-Excellence
SC-PRM Compressors insulation (SC)-Premium
ST-EXC Standard (ST)-Excellence
ST-PRM Standard (ST)-Premium
ACCESSORIES
A full list of accessories is available on page 76.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
48
CAUTION!
For trouble-free operation of the unit it is essential to
C
maintain the safety distances indicated by the green areas.
B1
A2
B
A
B2
A1
Size – KCFM 200.2 210.2 220.2 240.2 260.2 280.2 320.2 340.2 360.2 400.2 440.2 500.2 540.2 580.2
SC A - Length mm 5110 5110 6088 6088 6088 7092 7092 8067 8067 9043 9043 10989 10989 10989
SC B - Width mm 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246 2246
SC C - Height mm 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673 2673
SC A1 mm 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690 1690
SC A2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
SC B1 mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
SC B2 mm 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
SC Operating weight kg 6040 6100 7220 7435 7533 8259 8453 9317 9685 10855 10999 12080 12488 12708
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
SC: Acoustic configuration with compressor soundproofing
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
49
ACOUSTIC CONFIGURATION:
DOUBLE SET POINT:
SC Acoustic configuration with compressor soundproofing
- Double set point: not required (Standard)
EN Extremely low noise acoustic configuration
DSP Double set point
DSPB Double set point for water low temperature
FREE COOLING:
FDC Direct FREE COOLING (Standard)
LOW TEMPERATURE:
FCI Direct FREE COOLING
- Low temperature: not required (Standard)
B Water low temperature
VERSION:
EXC Excellence (Standard)
TECHNICAL DATA
Size – KCFM 200.2 210.2 220.2 240.2 260.2 280.2 320.2 340.2 360.2 400.2 440.2 500.2 540.2 580.2
FREE-COOLING OFF
SC
Cooling capacity (1) kW 523 548 591 629 682 765 838 899 961 1061 1191 1298 1428 1548
SC Total power input (1) kW 158 166 177 184 203 226 247 267 288 314 354 393 427 455
SC EER (1) - 3.30 3.31 3.35 3.42 3.37 3.38 3.40 3.37 3.33 3.38 3.36 3.30 3.35 3.40
FREE-COOLING
SC
Cooling capacity (2) kW 340 348 447 447 455 568 567 615 618 726 744 964 982 982
SC Total power input (2) kW 12.5 12.6 15.4 15.6 15.8 18.7 19.1 21.9 22.3 24.9 25.4 30.8 31.2 31.8
SC EER (2) - 27.3 27.6 29.0 28.7 28.8 30.4 29.7 28.0 27.8 29.1 29.3 31.3 31.5 30.8
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
No. of compressors Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Type of compressors (3) - DSW
Standard power supply V 400/3~/50
Notes
(1) Data referred to the following conditions: internal exchanger water = 15/10°C; glycol 30%; entering external exchanger air
temperature 30°C
(2) Internal exchanger water temperature = 15 / 10°C;
External exchanger entering air temperature = 2°C D.B. / 1°C W.B.; Glycol 30%
(3) DSW = twin-screw compressor
PRELIMINARY DATA
ACCESSORIES
A full list of accessories is available on page 76.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
50
KCNE / KCOE water chillers and heat pumps are indoor units with
ducted condensation.
CAUTION!
For trouble-free operation of the unit it is essential to
C
maintain the safety distances indicated by the green areas.
A1
A B2
B
A2 B1
Size - KCNE 122 162 182 222 262 302 352 402
A - Length mm 1450 1450 1875 1875 2650 2650 2650 2650
B - Width mm 780 780 780 780 780 780 780 780
C - Height mm 1995 1995 1995 1995 1995 1995 1995 1995
A1 mm 100 100 100 100 100 100 100 100
A2 mm 500 500 500 500 500 500 500 500
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 1300 1300 1300 1300 1300 1300 1300 1300
Operating weight kg 463 513 572 578 676 711 836 836
Size - KCOE 122 162 182 222 262 302 352 402
A - Length mm 1450 1450 1875 1875 2650 2650 2650 2650
B - Width mm 780 780 780 780 780 780 780 780
C - Height mm 1995 1995 1995 1995 1995 1995 1995 1995
A1 mm 100 100 100 100 100 100 100 100
A2 mm 500 500 500 500 500 500 500 500
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 1300 1300 1300 1300 1300 1300 1300 1300
Operating weight kg 501 555 620 626 732 770 874 904
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
51
ENERGY RECOVERY:
- Energy recovery: not required (Standard)
D Partial energy recovery
TECHNICAL DATA
Size – KCNE 122 162 182 222 262 302 352 402
Cooling capacity (EN14511:2013) (1) kW 36.1 41.7 49.3 58.3 67.5 78.6 89.8 102
Total power input (EN14511:2013) (1) kW 12.8 14.9 17.6 21.4 24.7 27.9 32.1 37.7
EER (EN 14511:2013) (1) - 2.83 2.80 2.81 2.72 2.74 2.81 2.79 2.70
ESEER (1) - 4.24 4.39 4.42 4.37 4.34 4.32 4.45 4.41
Refrigeration circuits Nr 1 1 1 1 1 1 1 1
No. of compressors Nr 2 2 2 2 2 2 2 2
Type of compressors (2) - SCROLL
Standard airflow l/s 4444 4444 5000 5000 6667 7500 7500 8333
Max external static pressure Pa 570 570 450 450 570 450 420 240
Standard power supply V 400/3~/50
Sound power in the duct dB(A) 76 77 80 81 79 82 84 87
Sound pressure level (3) dB(A) 59 60 63 64 61 65 66 70
Size – KCOE 122 162 182 222 262 302 352 402
Cooling capacity (EN14511:2013) (5) kW 33.9 41.0 47.6 54.5 64.5 75.0 86.3 98.9
Total power input (EN14511:2013) (5) kW 15.9 17.7 20.5 24.9 27.5 31.5 37.4 41.6
EER (EN 14511:2013) (5) - 2.13 2.32 2.32 2.19 2.35 2.38 2.31 2.38
ESEER (5) - 2.93 3.12 3.14 3.14 3.37 3.21 3.43 3.53
Heating capacity (EN14511:2013) (6) kW 41.0 48.3 59.0 68.0 80.0 92.4 103 112
Total power input (EN14511:2013) (6) kW 13.3 15.5 18.7 21.4 25.1 28.7 32.6 36.8
COP (EN 14511:2013) (6) - 3.09 3.12 3.16 3.17 3.19 3.22 3.17 3.05
Refrigeration circuits Nr 1 1 1 1 1 1 1 1
No. of compressors Nr 2 2 2 2 2 2 2 2
Type of compressors (2) - SCROLL
Standard airflow l/s 4444 4444 5000 5000 6667 7500 7500 7500
Max external static pressure Pa 510 510 390 390 570 390 390 390
Water flow-rate (User Side) (4) l/s 1.56 1.89 2.19 2.51 3.10 3.60 4.04 4.54
Standard power supply V 400/3~/50
Sound power in the duct (7) dB(A) 84 84 87 87 84 87 87 87
Sound pressure level (3) dB(A) 61 62 65 67 67 68 69 70
Notes
(1) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: Internal exchanger water
temperature = 12/7°C; Entering External exchanger air temperature = 35°C
(2) SCROLL = scroll compressor
(3) Sound levels refer to standard units (no accessories) at full load. The sound pressure is measured at 1 m from the external
surface of the ducted unit operating in an open field. (standard UNI EN ISO 9614-2); Data referred to the following conditions:
Internal exchanger water temperature = 12/7°C; Outdoor air temperature 35°C; Static available pressure 120 Pa; Please note
that when the unit is installed in conditions different from nominal test conditions (e.g. near walls or obstacles in general), the
sound levels may undergo substantial variations.
(4) Data referred to the following conditions: Internal exchanger water temperature = 12/7°C; Entering eExternal exchanger air
temperature = 35°C
(5) Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature =
12/7°C - Entering external exchanger air temperature = 35°C
(6) Data calculated in compliance with Standard UNI-EN14511:2013 referred to the following conditions:Internal exchanger water
temperature = 40/45°C, entering external exchanger air temperature = 7°C D.B. / 6°C W.B.
(7) Sound power measured in accordance with UNI EN ISO 9614 and Eurovent 8/1 standards for ducted unit with available
pressure equal to 120 Pa.
ACCESSORIES
A full list of accessories is available on page 76.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
52
CAUTION!
For trouble-free operation of the unit it is essential to
C
maintain the safety distances indicated by the green areas.
A2
B1 A
B
B2 A1
Size - KCRE 432 452 552 602 702 80D 90D 100D 110D 120D
A - Length mm 3312 3312 3312 3312 4400 4400 5486 5486 5486 5486
B - Width mm 1151 1151 1151 1151 1151 1151 1151 1151 1151 1151
C - Height mm 2326 2326 2326 2326 2326 2326 2326 2326 2326 2326
A1 mm 900 900 900 900 900 900 900 900 900 900
A2 mm 900 900 900 900 900 900 900 900 900 900
B1 mm 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300
B2 mm 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300
Operating weight kg 1430 1384 1507 1573 1861 1994 2369 2561 2695 2737
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
53
ENERGY RECOVERY:
- Energy recovery: not required (Standard)
D Partial energy recovery
R Total energy recovery (sizes 702 - 120D)
TECHNICAL DATA
Size – KCRE 432 452 552 602 702 80D 90D 100D 110D 120D
Cooling capacity (EN14511:2013) (1) kW 115 122 147 166 184 199 238 268 295 318
Total power input (EN14511:2013) (1) kW 41.6 45.0 54.1 61.4 66.6 72.6 87.7 99.0 109 126
EER (EN 14511:2013) (1) - 2.77 2.72 2.71 2.71 2.76 2.75 2.71 2.71 2.70 2.52
ESEER - 4.24 4.13 4.07 4.11 4.26 4.41 4.18 4.15 4.16 3.92
Refrigeration circuits Nr 1 1 1 1 1 2 2 2 2 2
No. of compressors Nr 2 2 2 2 2 4 4 4 4 4
Type of compressors (2) - SCROLL
Standard airflow l/s 12333 12333 12333 12333 16444 16444 20556 20556 21389 22222
Standard power supply V 400/3/50
Sound power in the duct (3) dB(A) 92 92 92 92 93 93 95 95 96 97
Notes
(1) Data compliant to Standard EN 14511:2013 referred to the following conditions: - Internal exchanger water temperature =
12/7°C - Entering external exchanger air temperature = 35°C
(2) SCROLL = scroll compressor
(3) Sound power measured in accordance with UNI EN ISO 9614 and Eurovent 8/1 standards for ducted unit with available
pressure equal to 120 Pa.
ACCESSORIES
A full list of accessories is available on page 77.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
54
FUNCTIONS AND FEATURES
CAUTION!
For trouble-free operation of the unit it is essential to
C
maintain the safety distances indicated by the green areas.
A1
A B
A2 B1
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
55
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
56
Notes
(1) Data referred to the following conditions: Internal exchanger water = 23/18°C; External exchanger water = 30/35°C
(2) Data referred to the following conditions: Internal exchanger water = 12/7°C; External exchanger water = 30/35°C
ACCESSORIES
A full list of accessories is available on page 77.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
57
NOTES
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………………………
…………………….......................................................................................................................
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
58
KCGW / KCHW are water cooled water chillers and heat pumps for
indoor installation, ideal for multi-family and commercial buildings.
The main features are:
HIGH SEASONAL EFFICIENCY - The combination of different size
compressors allows to gain more control steps, to provide the
energy actually required by the system, to reduce the consumption
and to achieve the high seasonal efficiency. The unit reaches
the Eurovent Class A heating and cooling for use with underfloor
heating.
VERSION GROUND WATER OR GEOTHERMAL - The use of heat
exchangers for specific applications with ground water or
geothermal closed loop maximize the energy efficiency.
PREASSEMBLED UNIT - All major components are provided on the FUNCTIONS AND FEATURES
unit, ensuring maximum reliability and ease of installation.
MODULARITY AND MANAGEMENT OF MORE UNITS IN CASCADE - The
compact construction allows to combine multiple units in confined
spaces, offering a high power system. The control allows to Cooling only Heat pump Water cooled Indoor installation R-410A
(KCGW) (KCHW)
coordinate up to 7 units managing automatically the operation with
maximum efficiency.
CAUTION!
C
For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
A1
B2
A
B
A2
B1
Size - KCGW 10.2 12.2 14.2 16.2 19.2 22.2 27.2 30.2 35.2 40.2 43.2 45.2 50.2 55.2 60.2 70.2 80.2 90.2 100.2 120.2
A - Length mm 837 837 837 837 837 837 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110
B - Width mm 607 607 607 607 607 607 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040
C - Height mm 1481 1481 1481 1481 1481 1481 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907
A1 mm 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
A2 mm 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
B1 mm 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
B2 mm 300 300 300 300 300 300 350 350 350 350 350 350 350 350 350 350 350 350 350 350
Operating weight kg 260 260 277 328 355 361 471 476 580 631 710 675 792 814 863 932 990 1075 1410 1533
Size - KCHW 10.2 12.2 14.2 16.2 19.2 22.2 27.2 30.2 35.2 40.2 43.2 45.2 50.2 55.2 60.2 70.2 80.2 90.2 100.2 120.2
A - Length mm 837 837 837 837 837 837 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110 1110
B - Width mm 607 607 607 607 607 607 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040 1040
C - Height mm 1481 1481 1481 1481 1481 1481 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907 1907
A1 mm 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
A2 mm 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
B1 mm 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500
B2 mm 300 300 300 300 300 300 350 350 350 350 350 350 350 350 350 350 350 350 350 350
Operating weight kg 279 279 286 356 377 383 501 506 592 670 749 687 838 861 878 995 1006 1106 1504 1666
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
59
ENERGY RECOVERY:
- Energy recovery: not required (Standard)
D Partial energy recovery
TECHNICAL DATA
Size – KCGW 10.2 12.2 14.2 16.2 19.2 22.2 27.2 30.2 35.2 40.2 43.2 45.2 50.2 55.2 60.2 70.2 80.2 90.2 100.2 120.2
Cooling capacity (EN14511:2013) (1) kW 30.8 35.4 42.7 49.6 59.1 68.4 84.0 94.0 109 123 135 147 159 173 197 221 249 280 305 356
Total power input (EN14511:2013) (1) kW 6.45 7.63 9.22 10.8 12.5 15.6 17.5 20.4 23.5 26.6 29.8 31.5 34.1 37.7 42.7 48.2 54.7 61.5 68.4 82.4
EER (EN 14511:2013) (1) - 4.77 4.64 4.63 4.61 4.72 4.39 4.80 4.63 4.62 4.63 4.53 4.65 4.68 4.58 4.60 4.59 4.55 4.56 4.46 4.32
ESEER (2) - 6.31 6.20 5.65 5.52 5.71 5.51 6.19 6.05 6.03 6.02 5.78 6.00 5.97 5.79 5.62 5.78 5.48 5.52 5.48 5.31
Heating capacity (EN14511:2013) (3) kW 35.8 41.4 49.6 57.8 68.6 81.0 96.3 109 126 143 157 169 184 200 227 257 290 328 355 420
Total power input (EN14511:2013) (3) kW 8.27 9.79 11.6 13.5 15.7 19.2 21.9 25.3 28.9 32.9 36.7 38.7 41.9 46.5 52.4 59.3 66.7 76.6 83.4 101
COP (EN 14511:2013) (3) - 4.33 4.23 4.26 4.29 4.37 4.23 4.43 4.32 4.35 4.35 4.27 4.37 4.39 4.30 4.33 4.34 4.34 4.28 4.25 4.16
Refrigeration circuits Nr 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
No. of compressors Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Type of compressors - SCROLL
Standard power supply V 400/3/50
Max. leaving water temperature °C 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Sound pressure level (4) dB(A) 44 44 45 49 49 49 49 49 58 58 60 58 60 60 61 63 63 64 64 65
Size – KCHW 10.2 12.2 14.2 16.2 19.2 22.2 27.2 30.2 35.2 40.2 43.2 45.2 50.2 55.2 60.2 70.2 80.2 90.2 100.2 120.2
Cooling capacity (EN14511:2013) (5) kW 29.2 34.4 40.7 48.4 57.7 67.6 82.0 91.8 102 120 131 138 155 168 187 217 240 265 292 347
Total power input (EN14511:2013) (5) kW 6.40 7.50 9.10 10.6 12.5 15.4 17.5 20.5 23.6 26.8 29.9 31.7 34.2 37.7 42.6 48.2 54.5 61.4 67.8 81.7
EER (EN 14511:2013) (5) - 4.57 4.58 4.47 4.56 4.62 4.38 4.68 4.49 4.32 4.47 4.38 4.37 4.52 4.46 4.38 4.50 4.40 4.31 4.31 4.25
ESEER (2) - 5.99 5.77 5.39 5.27 5.44 5.25 5.87 5.66 5.71 5.69 5.49 5.74 5.65 5.50 5.41 5.54 5.24 5.28 5.34 5.28
Heating capacity (EN14511:2013) (6) kW 34.4 40.4 48.0 56.8 67.0 79.5 93.8 107 119 139 151 163 178 195 218 252 280 314 343 408
Total power input (EN14511:2013) (6) kW 8.18 9.65 11.6 13.4 15.7 19.1 21.4 24.7 28.3 32.3 36.0 38.4 41.3 45.7 51.9 58.0 65.5 75.3 82.5 100
COP (EN 14511:2013) (6) - 4.20 4.19 4.15 4.25 4.27 4.15 4.38 4.32 4.21 4.30 4.18 4.24 4.32 4.27 4.20 4.34 4.27 4.17 4.16 4.07
Refrigeration circuits Nr 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
No. of compressors Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Type of compressors - SCROLL
Standard power supply V 400/3/50
Max. leaving water temperature °C 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Sound pressure level (4) dB(A) 44 44 45 49 49 49 49 49 58 58 60 58 60 60 61 63 63 64 64 65
Notes
(1) Data referred to the following conditions: Internal exchanger water = 12/7°C; External exchanger water = 30/35°C;
Performance data calculated in accordance with UNI-EN14511:2013; The unit can operate in cooling-only or in heating-only
mode. To be able to operate in both modes, the system must be designed with a water circuit change-over.
(2) ESEER calculated by EUROVENT, for systems featuring terminal units with water produced at 7°C; Performance data calculated
in accordance with UNI-EN14511:2013
(3) Data referred to the following conditions: Water to internal exchanger 40/45°C; Water temperature to external exchanger
10/7 °C; Performance data calculated in accordance with UNI-EN14511:2013; The unit can operate in cooling-only or in heating
only mode. To be able to operate in both modes, the system must be designed with a water circuit change-over.
(4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the
external surface of the unit in open field conditions.
(5) Data referred to the following conditions: Internal exchanger water = 12/7°C; External exchanger water = 30/35°C;
Performance data calculated in accordance with UNI-EN14511:2013
(6) Data referred to the following conditions: Water to internal exchanger 40/45°C; Water temperature to external exchanger
10/7°C; Performance data calculated in accordance with UNI-EN14511:2013
ACCESSORIES
A full list of accessories is available on page 77.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
60
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
61
CAPACITY MODULATION
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
62
C
CAUTION!
For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
B2
A1
A B
A2
B1
Size - KCGC 65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F
A - Length mm 2547 2547 2547 2547 2552 2552 2552 2552 2552 2552 3062 3062 3062 3062
B - Width mm 850 850 850 850 850 850 850 850 850 850 850 850 850 850
C - Height mm 1886 1886 1886 1886 1886 1886 1886 1886 1886 1886 1886 1886 1886 1886
A1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
A2 mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
Operating weight kg 1238 1320 1360 1397 1489 1490 1604 1694 1723 1731 2012 2272 2409 2406
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
63
ACOUSTIC CONFIGURATION:
ST Standard acoustic configuration
EN Extremely low noise acoustic configuration
TECHNICAL DATA
Size – KCGC 65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F
ST/EN Cooling
capacity (EN14511:2013) (1) kW 194 206 222 233 250 285 311 333 352 370 404 438 495 558
ST/EN Total power input (EN14511:2013) (1) kW 43.3 46.5 49.8 52.5 55.5 62.1 67.5 72.8 78.3 82.5 89.9 97.8 110 126
ST/EN EER (EN 14511:2013) (1) - 4.48 4.43 4.46 4.44 4.51 4.59 4.61 4.57 4.49 4.48 4.50 4.48 4.50 4.44
ST/EN ESEER (1) - 5.40 5.42 5.11 5.34 5.17 5.31 5.21 5.44 5.39 5.37 5.40 5.56 5.50 5.52
ST/EN Heating
capacity (EN14511:2013) (2) kW 224 237 257 269 289 327 356 383 407 428 466 506 574 646
ST/EN Total power input (EN14511:2013) (2) kW 51.2 55.0 58.2 61.6 64.9 73.2 79.9 86.6 93.1 98.2 107 115 130 147
ST/EN COP (EN 14511:2013) (2) - 4.38 4.31 4.42 4.37 4.45 4.47 4.46 4.42 4.37 4.36 4.36 4.40 4.42 4.39
ST/EN Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/EN No. of compressors Nr 4 4 4 4 4 4 4 4 4 4 5 6 6 6
ST/EN Type of compressors - SCROLL
ST/EN Standard power supply V 400/3/50
ST Sound pressure level (3) dB(A) 73 74 74 74 74 74 76 76 76 76 76 76 77 77
EN Sound pressure level (3) dB(A) 64 64 65 65 66 66 67 68 68 68 68 68 68 69
Notes
(1) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions: - internal exchanger water
(evaporator) = 12/7°C - external exchanger water (condenser) = 30/35°C
(2) Data referred to unit in ‘OHI - Operation with water circuit change-over’ configuration; Data calculated in compliance with
Standard EN 14511:2013 referred to the following conditions: - internal exchanger water (evaporator) = 12/7°C - external
exchanger water (condenser) = 40/45°C
(3) Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. The sound levels refer
to the unit at full load, in the rated test conditions.
The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Data
referred to the following conditions: Internal exchanger water = 12/7°C; External exchanger water = 30/35°C
ST Standard (ST)
EN Extremely low noise (EN)
ACCESSORIES
A full list of accessories is available on page 78.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
64
CAUTION!
C For trouble-free operation of the unit it is essential to
maintain the safety distances indicated by the green areas.
A1
A B2
B
A2 B1
Size - KCGC 65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F
A - Length mm 4266 4266 4266 4266 4266 4266 4266 4266 4266 4266 4723 4723 4723 4723
B - Width mm 850 850 850 850 850 850 850 850 850 850 850 850 850 850
C - Height mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
A1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
A2 mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
Operating weight kg 1238 1320 1360 1397 1489 1490 1604 1694 1723 1731 2012 2272 2409 2406
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
65
TECHNICAL DATA
Size – KCGC 65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F
COOLING 0% - HEATING 100%
Heating capacity (1) kW 224 237 257 269 289 327 356 383 407 428 466 506 574 646
Total power input kW 51.4 55.2 58.4 61.8 65.1 73.4 80.1 86.8 93.3 98.4 107 116 130 148
COP at full load - 4.36 4.29 4.40 4.36 4.43 4.45 4.44 4.41 4.36 4.35 4.37 4.38 4.41 4.37
COOLING 100% - HEATING 0%
Cooling capacity (2) kW 212 227 243 255 272 311 341 364 385 404 443 480 539 608
Total power input kW 32.6 34.8 37.9 39.9 43.6 47.4 52.2 55.7 59.6 62.4 68.2 74.6 83.6 94.4
EER at full load - 6.50 6.51 6.41 6.38 6.25 6.56 6.54 6.54 6.46 6.48 6.50 6.46 6.45 6.44
COOLING 100% - HEATING 100%
Cooling capacity (3) kW 173 182 199 208 224 254 276 297 314 330 360 391 444 500
Heating capacity (3) kW 224 237 257 269 289 327 356 383 407 428 466 506 574 646
Total power input kW 51.4 55.2 58.4 61.8 65.1 73.4 80.1 86.8 93.3 98.4 107 116 130 148
Overall efficiency - 7.73 7.59 7.80 7.72 7.88 7.91 7.89 7.83 7.72 7.70 7.74 7.76 7.83 7.74
Standard (ST)/Extremely low noise(EN)
Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
No. of compressors Nr 4 4 4 4 4 4 4 4 4 4 5 6 6 6
Type of compressors - SCROLL
Standard power supply V 400/3/50
Standard (ST)
Sound pressure level (4) dB(A) 73 74 74 74 74 74 76 76 76 76 76 76 77 77
Super-silenced (EN)
Sound pressure level (4) dB(A) 64 64 65 65 66 66 67 68 68 68 68 68 68 69
Notes
(1) Heating water circuit = 45/40°C; Source water circuit = 12/7°C
(2) Cooling water circuit = 7/12°C; Source water circuit = 15/25°C
(3) Cooling water circuit = 7/12°C; Heating water circuit = 45/40°C
(4) Measures according to UNI EN ISO 9614-2 regulations, with respect to the EUROVENT 8/1 certification. The sound levels refer
to the unit at full load, in the rated test conditions.
The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Data
referred to the following conditions: Internal exchanger water = 12/7°C; External exchanger water = 30/35°C
ACCESSORIES
A full list of accessories is available on page 78.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
66
The KCGK units are water chillers with extremely high efficiency that
feature:
MAXIMUM ENERGY SAVING - Excellence version is placed in Eurovent
Energy Efficiency Class A and stands for high efficiency at partial load
operation with continuous modulation of the compressor capacity
from 100% to 25%.
HIGH TEMPERATURES - The configuration HWT (High Water
Temperature) is particularly suitable for high leaving water
temperature up to 65°C.
PERFECT FOR GREEN BUILDINGS - Top efficiency figures match
with demanding protocols such as ECBC and LEED certification
requirements. The refrigerant is zero-ODP. Furthermore, its quantity
is much smaller than most of the market chillers can do, such as
flooded evaporator models, thus further increasing the relevant design
credits.
RELIABLE TECHNOLOGY - Excellent energy figures originate from high
performance double screw compressor complete with electronic
FUNCTIONS AND FEATURES
thermostatic valve and innovative shell & tube heat exchangers
optimized for operation with R-134a. Single compressor units are
especially suitable for parallel system configuration (Ecoshare), while
two compressors design allows more reliability, higher flexibility and Cooling only Water cooled Indoor installation R-134a Semi-hermetic
Twin-screw
low starting current.
HIGHLY VERSATILE APPLICATION - Suitable for all terminal types, from
fan coil units to radiant systems and chilled beams, KCGK is also
available for low temperature supply (Brine) in high dehumidification Reversible water
circuit
Electronic expansion
valve
or industrial process applications. On the source side, it can easily
benefit from tower, dry cooler or well water plant design.
120.1÷290.1
A2
CAUTION!
B1 A For trouble-free operation of the unit it is essential to
B
B 1
C maintain the safety distances indicated by the green areas.
2 A
A2
220.2÷580.2
B1 A
B
B2
A1
Size – KCGK 120.1 140.1 160.1 180.1 200.1 220.1 250.1 270.1 290.1
A - Length mm 4624 4624 4624 4609 4609 4609 4609 4609 4609
B - Width mm 1350 1350 1350 1350 1350 1350 1350 1350 1350
ST-EXC C - Height mm 1574 1574 1574 1660 1660 1660 1660 1660 1660
EN-EXC C - Height mm 1574 1574 1574 1750 1750 1750 1750 1750 1750
A1 mm 700 700 700 700 700 700 700 700 700
A2 mm 700 700 700 700 700 700 700 700 700
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 1160 1160 1160 1170 1170 1170 1170 1170 1170
ST-EXC Operating weight kg 2377 2457 2514 3263 3274 3352 3403 3530 3561
EN-EXC Operating weight kg 2541 2650 2707 3486 3497 3575 3626 3753 3784
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
67
Size – KCGK 220.2 240.2 260.2 280.2 300.2 320.2 340.2 360.2 400.2 440.2 470.2 500.2 540.2 580.2
A - Length mm 4639 4639 4639 4639 4639 4639 5006 5006 5010 5010 5010 5076 5076 5076
B - Width mm 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350
ST-EXC C - Height mm 2000 2000 2000 2000 2000 2000 2270 2270 2270 2270 2270 2405 2405 2405
EN-EXC C - Height mm 2100 2100 2100 2100 2100 2100 2382 2382 2382 2382 2382 2500 2500 2500
A1 mm 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410
A2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
ST-EXC Operating weight kg 3936 3967 4043 4068 4123 4179 5246 5473 5600 5750 5799 6641 6830 6889
EN-EXC Operating weight kg 4264 4295 4400 4454 4509 4565 5662 5919 6046 6196 6245 7087 7276 7335
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative.
ST-EXC Standard (ST)-Excellence EN-EXC Super-silenced (EN)-Excellence
ENERGY RECOVERY:
LOW TEMPERATURE:
- Low temperature: not required (Standard) - Energy recovery: not required (Standard)
B Water low temperature D Partial energy recovery
R Total energy recovery
ACOUSTIC CONFIGURATION:
VERSION:
ST Standard acoustic configuration
EXC Excellence (Standard)
EN Extremely low noise acoustic configuration
OPERATION: APPLICATION:
OCO Cooling only operation (Standard) T Cooling tower application (Standard)
OHI Operation with water circuit change-over P Groundwater application
TECHNICAL DATA
Size – KCGK 120.1 140.1 160.1 180.1 200.1 220.1 250.1 270.1 290.1
ST/EN-EXC Cooling
capacity (EN14511:2013) (1) kW 325 392 430 504 550 613 668 736 782
ST/EN-EXC Total power input (EN14511:2013) (1) kW 63.0 76.6 85.0 96.6 106 118 130 144 155
ST/EN-EXC EER (EN 14511:2013) (1) - 5.15 5.12 5.05 5.22 5.19 5.19 5.13 5.13 5.05
ST/EN-EXC ESEER - 5.51 5.50 5.46 5.56 5.56 5.55 5.54 5.52 5.41
ST/EN-EXC Heating
capacity (EN14511:2013) (2) kW 360 439 482 560 612 682 745 821 874
ST/EN-EXC Total power input (EN14511:2013) (2) kW 75.3 90.2 99.9 114 125 139 153 169 182
ST/EN-EXC COP (EN 14511:2013) (2) - 4.79 4.87 4.83 4.92 4.91 4.90 4.86 4.87 4.81
ST/EN-EXC Refrigeration circuits Nr 1 1 1 1 1 1 1 1 1
ST/EN-EXC No. of compressors Nr 1 1 1 1 1 1 1 1 1
ST/EN-EXC Type of compressors (3) - DSW
ST/EN-EXC Standard power supply V 400/3~/50
ST-EXC Sound pressure level (4) dB(A) 70 75 75 78 78 79 80 81 81
EN-EXC Sound pressure level (4) dB(A) 65 69 70 72 72 73 74 75 75
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
68
Size – KCGK 220.2 240.2 260.2 280.2 300.2 320.2 340.2 360.2 400.2 440.2 470.2 500.2 540.2 580.2
ST/EN-EXC Cooling
capacity (EN14511:2013) (1) 599 638 693 780 817 855 922 975 1077 1207 1251 1329 1452 1535
ST/EN-EXC Total power input (EN14511:2013) (1) 116 125 137 152 161 169 178 190 211 236 247 258 282 304
ST/EN-EXC EER (EN 14511:2013) (1) 5.16 5.12 5.05 5.13 5.07 5.05 5.19 5.13 5.11 5.12 5.06 5.15 5.14 5.05
ST/EN-EXC ESEER 5.77 5.78 5.73 5.74 5.71 5.71 5.83 5.80 5.72 5.75 5.70 5.82 5.82 5.66
ST/EN-EXC Heating
capacity (EN14511:2013) (2) 668 712 779 875 918 962 1030 1096 1210 1354 1409 1482 1618 1727
ST/EN-EXC Total power input (EN14511:2013) (2) 137 149 163 179 190 199 210 225 248 278 292 304 333 360
ST/EN-EXC COP (EN 14511:2013) (2) 4.87 4.78 4.77 4.88 4.84 4.83 4.90 4.87 4.87 4.87 4.83 4.87 4.86 4.80
ST/EN-EXC Refrigeration circuits 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/EN-EXC No. of compressors 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/EN-EXC Type of compressors (3) DSW
ST/EN-EXC Standard power supply 400/3~/50
ST-EXC Sound pressure level (4) 73 73 76 78 78 78 79 81 81 83 83 83 84 84
EN-EXC Sound pressure level (4) 68 68 70 72 72 73 73 75 75 77 78 77 78 78
Notes
(*) The programme applies to water chillers up to 1500 kW.
(1) Data calculated in compliance with Standard EN 14511:2013 referred to the following conditions:
Internal exchanger water = 12/7°C; External exchanger water = 30/35°C
(2) Data referred to unit in ‘OHI - Operation with water circuit change-over’ configuration; Data calculated in compliance with
Standard EN 14511:2013 referred to the following conditions: Internal exchanger water = 12/7°C;
External exchanger water = 40/45°C
(3) DSW = twin-screw compressor
(4) Sound levels refer to full load units, in test nominal conditions. The sound pressure level refers to 1 m. from the standard unit
outer surface operating in open field. Measurements are carried out according to the UNI EN ISO 9614-2 standard, in
compliance with the EUROVENT 8/1 certification. Data referred to the following conditions: Internal exchanger water = 12/7°C;
External exchanger water = 30/35°C
EN-EXC Extremely low noise (EN)-Excellence
ST-EXC Standard (ST)-Excellence
ACCESSORIES
A full list of accessories is available on page 78.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
69
The KCGL units are particularly suited in civil and industrial sector
systems in the following applications:
BUILDINGS WITH ARCHITECTURAL VALUE - The chiller is normally
installed in a service room and therefore completely concealed from
sight, whereas the outdoor exchange section can be positioned
remotely.
EXTREMELY LOW NOISE EMISSION - Separated from the chiller, the
outdoor exchange section can be selected and sized as required to
reduce noise emission.
PARTICULARLY SEVERE CLIMATES - The two section solution makes
it possible to avoid having an outdoor water system and therefore
having to perform the winter emptying needed to protect it against
freezing. With KCGL, the pipes between the two sections contain a
refrigerant fluid and not water. FUNCTIONS AND FEATURES
Electronic expansion
valve
C
120.1÷290.1
CAUTION!
For trouble-free operation of the unit it is essential to
2
A
maintain the safety distances indicated by the green areas.
B1
B A
B2 C
A1
A2
B1 A
B
220.2÷580.2 B2
A1
Size – KCGL 120.1 140.1 160.1 180.1 200.1 220.1 250.1 270.1 290.1
A - Length mm 4210 4210 4210 4189 4189 4189 4189 4324 4324
B - Width mm 1350 1350 1350 1350 1350 1350 1350 1350 1350
ST-EXC C - Height mm 1558 1558 1558 1642 1642 1642 1642 1657 1657
EN-EXC C - Height mm 1573 1573 1573 1750 1750 1750 1750 1750 1750
A1 mm 700 700 700 700 700 700 700 700 700
A2 mm 700 700 700 700 700 700 700 700 700
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 1160 1160 1160 1160 1160 1160 1160 1160 1160
ST-EXC Operating weight kg 2073 2152 2229 2821 2832 2843 2895 2981 3012
EN-EXC Operating weight kg 2237 2345 2422 3044 3055 3066 3118 3204 3235
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
70
Size – KCGL 220.2 240.2 260.2 280.2 300.2 320.2 340.2 360.2 400.2 440.2 470.2 500.2 540.2 580.2
A - Length mm 4638 4638 4638 4638 4638 4638 4992 4992 5006 5006 5006 5077 5077 5077
B - Width mm 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350 1350
ST-EXC C - Height mm 1790 1790 1790 1790 1790 1790 1995 1995 2010 2010 2010 2145 2145 2145
EN-EXC C - Height mm 1900 1900 1900 1900 1900 1900 2121 2121 2121 2121 2121 2239 2239 2239
A1 mm 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410 1410
A2 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 700
B1 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
B2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
ST-EXC Operating weight kg 3390 3422 3497 3587 3681 3745 4448 4675 4763 4784 4832 5680 5817 5876
EN-EXC Operating weight kg 3830 3862 3966 4013 4107 4171 5010 5267 5388 5445 5493 6318 6455 6514
The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations
contact your Fläkt Woods representative. ST-EXC: Standard (ST) Excellence EN-EXC: Super-silenced (EN) Excellence
VERSION:
EXC Excellence (Standard)
TECHNICAL DATA
Size – KCGL 120.1 140.1 160.1 180.1 200.1 220.1 250.1 270.1 290.1
ST/EN-EXC Cooling
capacity (1) kW 300 364 401 466 508 566 620 683 728
ST/EN-EXC Compressor power input (1) kW 69.1 82.4 90.5 105 114 128 140 154 165
ST/EN-EXC Total power input (1) kW 69.6 82.9 91.0 105 114 128 140 154 165
ST/EN-EXC EER (2) - 4.35 4.42 4.43 4.44 4.46 4.42 4.43 4.44 4.42
ST/EN-EXC Refrigeration circuits Nr 1 1 1 1 1 1 1 1 1
ST/EN-EXC No. of compressors Nr 1 1 1 1 1 1 1 1 1
ST/EN-EXC Type of compressors (3) - DSW
ST/EN-EXC Standard power supply V 400/3/50
ST-EXC Sound pressure level (4) dB(A) 71 76 76 79 79 80 81 82 82
EN-EXC Sound pressure level (4) dB(A) 66 70 71 73 73 74 75 76 76
Size – KCGL 220.2 240.2 260.2 280.2 300.2 320.2 340.2 360.2 400.2 440.2 470.2 500.2 540.2 580.2
ST/EN-EXC Cooling
capacity (1) kW 550 585 642 720 757 794 848 899 997 1115 1159 1231 1344 1427
ST/EN-EXC Compressor power input (1) kW 128 137 150 164 173 181 195 208 228 255 267 280 307 329
ST/EN-EXC Total power input (1) kW 128 138 151 165 174 182 196 209 228 256 268 281 308 329
ST/EN-EXC EER (2) - 4.30 4.26 4.27 4.38 4.37 4.39 4.34 4.31 4.38 4.37 4.34 4.39 4.38 4.34
ST/EN-EXC Refrigeration circuits Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/EN-EXC No. of compressors Nr 2 2 2 2 2 2 2 2 2 2 2 2 2 2
ST/EN-EXC Type of compressors (3) - DSW
ST/EN-EXC Standard power supply V 400/3/50
ST-EXC Sound pressure level (4) dB(A) 74 74 77 79 79 79 80 82 82 84 84 84 85 85
EN-EXC Sound pressure level (4) dB(A) 69 69 71 73 73 74 74 76 76 78 79 78 79 79
Notes
The units are shipped with a sealed charge of nitrogen. (sizes 220.2-580.2)
(1) Data referred to the following conditions: Internal exchanger water = 12/7°C; Condensing temperature = 45°C
(2) EER referred only to compressors
(3) DSW = twin-screw compressor
(4) Sound levels refer to full load units, in test nominal conditions. The sound pressure level refers to 1 m. from the standard unit
outer surface operating in open field. Measurements are carried out according to the UNI EN ISO 9614-2 standard, in
compliance with the EUROVENT 8/1 certification. Data referred to the following conditions: Internal exchanger water = 12/7°C;
Condensing temperature = 45°C
EN-EXC Extremely low noise (EN)-Excellence ST-EXC Standard (ST)-Excellence
ACCESSORIES
A full list of accessories is available on page 79.
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
71
ACCESSORIES
KCX Connection set ACS300X 300 litre domestic hot water storage tank (sizes 21-51)
MEN15 Minimum outdoor air temperature down to -15°C ACS3SX 300 litre domestic hot water storage tank with solar coil (sizes
PGCEX Coil protection grilles outdoor air side ACS500X 500 litre domestic hot water storage tank (sizes 21-101)
PMX Phase monitor ACS5SX 500 litre domestic hot water storage tank with solar coil (sizes
KCSC - PAGE 10
AMMX Spring antivibration mounts KCDG - PAGE 17
CBS Overload circuit breakers 3DHWX Three way valve for domestic hot water
CCCA Copper / aluminium condenser coil with acrylic lining 3WV Three way valve
CCCA1 Condensor coil with Energy Guard DCC Alumium ACS500X 500 litre domestic hot water storage tank
CMPB Serial communication module to PC or BUS ACS5SX 500 litre domestic hot water storage tank with solar coil
PFCP Power factor correction capacitors (cosfi > 0.9) CCCA Copper / aluminium condenser coil with acrylic lining
PGFC Finned coil protection grill CCCA1 Condensor coil with Energy Guard DCC Alumium
RCMRX Remote control via microprocessor control EH246 Modular supplementary electric heater, from 2-4 and 6kW
KITERAX Electronic wall mounting room thermostat
KSAX 100 litre circuit breaker
KCSD - PAGE 12
KTFL1X 1" water side hose kit
AMMX Spring antivibration mounts
KTFL2X 1 1/4" water side hose kit
CCCA Copper / aluminium condenser coil with acrylic lining
KVICX Boiler control kit
CCCA1 Condensor coil with Energy Guard DCC Alumium
KVMSP1X Radiant panels management kit with 1" connections
CFSC Potential-free contacts for compressor status
KVMSP2X Kit management of radiant panels with connections of 1 1/4"
CMSC4 CAN/Modbus serial converter kit
PBLC1X Service keypad (cable from 1.5 metres)
CMSC6 CAN/LON WORKS serial converter kit
PMX Phase monitor
KCX Connection set
SFSTR4N Disposal for inrush current reductions, for unit 400/3/50+N
LR Liquid receiver
PFCP Power factor correction capacitors (cosfi > 0.9)
PGCC Finned coil protection grilles and compressor compartment
PGCCH Anti-hail protection grilles
PM Phase monitor
RCMRX Remote control via microprocessor control
SLS Inlet seperator
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
72
ACCESSORIES
KCAG / KCBG - PAGE 20 PFCP Power factor correction capacitors (cosfi > 0.9)
1PUM Single pump with larger available head PGCCH Anti-hail protection grilles
1PUR Single pump with reduced available head PGFC Finned coil protection grill
2PUM Double pump with larger available head PSX Mains power supply
2PUR Double pump with reduced available head (sizes 222-302) RCMRX Remote control via microprocessor control
2PUS Standard double pump SCP4 Set point compensation with signal 0-10V
ACC1 Teflon steel storage device SFSTR Disposal for inrush current reductions
amrx Rubber antivibration mounts SPC2 Set point compensation with outdoor air temperature probe
ccca Copper / aluminium condenser coil with acrylic lining KCAJ ONLY
CCCA1 Condensor coil with energy guard dcc alumium MF2 Multi-function phase monitor
CLSE Free contacts alarm RE-20 Electrical panel antifreeze protectionfor min. outdoor
CMSC7 Modbus/lon works serial converter kit RE-25 Electrical panel antifreeze protectionfor min. outdoor
IFWX Steel mesh strainer on the water side temperature down to 25°C
MHP High and low pressure guages RE-30 Electrical panel antifreeze protectionfor min. outdoor
temperature down to 30°C
PCDWX Daily and weekly programming clock
RE-35 Electrical panel antifreeze protectionfor min. outdoor
PFCP Power factor correction capacitors (cosfi > 0.9)
temperature down to 35°C
pgcex Coil protection grilles outdoor air side
RE-39 Electrical panel antifreeze protectionfor min. outdoor
pm Phase monitor
temperature down to 39°C
RCMRX Remote control via microprocessor control
FANQE Electrical panel ventilation
SCP3X Set point compensation according to the outside enthalpy
SDV Cutoff valve on compressor supply and return
SFSTR4N Disposal for inrush current reductions, for unit 400/3/50+N
KCBJ ONLY
KCAG ONLY
PM Phase monitor
SPCX Set point compensation with outdoor air temperature probe
OHE Limit extension kit in heating up to -10°C (W.B)
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
73
ACCESSORIES
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
74
ACCESSORIES
KCCC - PAGE 37 MEN15A Minimum outdoor air temperature with unit powered on but
2PM Hydropack load side with 2 pumps not operational down to -15°C
AMMX Spring antivibration mounts MEN18A Minimum outdoor air temperature with unit powered on but
CCCA Copper / aluminium condenser coil with acrylic lining not operational down to -18°C
CFSC Potential-free contacts for compressor status MEN18S Minimum storage outdoor air temperature down to -18°C
MHP High and low pressure guages MEN20A Minimum outdoor air temperature with unit powered on but
not operational down to -20°C
PFCP Power factor correction capacitors (cosfi > 0.9)
MEN20S Minimum storage outdoor air temperature down to -20°C
PGCC Finned coil protection grilles and compressor compartment
MEN25A Minimum outdoor air temperature with unit powered on but
PM Phase monitor
not operational down to -25°C
RCMRX Remote control via microprocessor control
MEN25S Minimum storage outdoor air temperature down to -25°C
SCP3 Set point compensation according to the outside enthalpy
MEN30A Minimum outdoor air temperature with unit powered on but
SDV Cutoff valve on compressor supply and return
not operational down to -30°C
SFSTR Disposal for inrush current reduction
MEN35A Minimum outdoor air temperature with unit powered on but
SPC1 Set point compensation with 4-20 mA signal
not operational down to - 35°C
SPC2 Set point compensation with outdoor temperture probe
MEN39A Minimum outdoor air temperature with unit powered on but
not operational down to -39°C
KCCK / KCDK - PAGE 39 MHP High and low pressure guages
2PM Hydropack load side with 2 pumps PFCP Power factor correction capacitors (cosfi > 0.9)
3PM Hydropack load side with 3 pumps PGCCH Anti-hail protection grilles
4PM Hydropack user side with 4 pumps PGFC Finned coil protection grill
6PM Hydropack user side with 6 pumps PIU20 Minimum outdoor air temperature up to +20°C
6PMV Hydropack user side with 6 inverter pumps PIU5 Minimum outdoor air temperature up to +5°C
A550 550L STORAGE TANKS PSX Mains power supply
A550PPS 550L storage tank with primary circuit with built in pump RCMRX Remote control via microprocessor control
A700 700L storage tanks RPRPDI Refrigerant leak detector with pump down function in the casing
A700PPS 700L storage tank with primary circuit with built in pump SDV Cutoff valve on compressor supply and return
A900 900L storage tanks SFSTR Disposal for inrush current reduction
A900PPS 900L storage tank with primary circuit with built in pump SPC1 Set point compensation with 4-20 mA signal
ACC Storage tank SPC2 Set point compensation with outdoor temperture probe
ACCPPS Storage tank and pump with primary circuit built in SCP4 Set point compensation with signal 0-10V
AMMX Spring antivibration mounts KCCK ONLY
CCCA Copper / aluminium condenser coil with acrylic lining CFSC Potential free contacts for compressor status
CCCA1 Condensor coil with Energy Guard DCC Alumium FANQE Electrical panal ventilation
CMSC10 Serial communication module to LonWorks supervisor IVFDT Inverter driven variable flow rate user side control depending
CMSC11 Serial communication module to BACnet-IP supervisor on the temperature differential
CMSC9 Serial communication module to Modbus supervisor MEN18 Minimum outdoor air temperature down to -18°C
CONTA2 Energy Meter MF2 Multi-function phase monitor
CREFB Device for consumption reduction of the exernal section PM Phase monitor
ECOBREEZE fans REGBT Device for stepping of condensing coils
CSVX Couple of manual shut off valves KCDK ONLY
DML0-10 Demand limit with signal 0-10V IVFDT Inverter driven variable flow rate user side control depending
DML4-20 Demand limit with signal 4-20mA on the temperature differential (SIZES 160.4, 260.8-480.8)
ECS ECOSHARE function for the automatic management of a OHE Limit extension kit in heating up to -10°C (W.B)
group of units
IFWX Steel mesh strainer on the water side
MEN10G Minimum outdoor air temperature down to -10°C
MEN15 Minimum outdoor air temperature down to -15°C
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
75
ACCESSORIES
KCEK - PAGE 42 MEN30A Minimum outdoor air temperature with unit powered on but
2PM Hydropack load side with 2 pumps not operational down to -30°C
2PMV Hydropack user side with 2 inverter pumps (sizes 90.4-120.4) MEN35A Minimum outdoor air temperature with unit powered on but
3PM Hydropack load side with 3 pumps not operational down to - 35°C
3PMV Hydropack user side with 3 inverter pumps MEN39A Minimum outdoor air temperature with unit powered on but
not operational down to -39°C
A550 550L storage tanks (sizes 90.4-120.4)
MHP High and low pressure guages
A550PPS 550L storage tank with primary circuit with built in pump
(sizes 90.4-120.4) OHE Limit extension kit in heating up to -10°C (W.B)
A700 700L storage tanks (sizes 140.4-160.4) PFCP Power factor correction capacitors (cosfi > 0.9)
A700PPS 700L storage tank with primary circuit with built in pump PGCCH Anti-hail protection grilles
A900 900L storage tanks (sizes 180.4-240.4) PIU20 Minimum outdoor air temperature up to +20°C
A900PPS 900L storage tank with primary circuit with built in pump PIU5 Minimum outdoor air temperature up to +5°C
AMMX Spring antivibration mounts RCMRX Remote control via microprocessor control
CAR Storage tank connection recovery side RPRPDI Refrigerant leak detector with pump down function in casing
CAU Storage tank connection user side SDV Cutoff valve on compressor supply and return
CCCA Copper / aluminium condenser coil with acrylic lining SFSTR Disposal for inrush current reduction
CCCA1 Condensor coil with Energy Guard DCC Alumium SPC1 Set point compensation with 4-20 mA signal
CMSC10 Serial communication module to LonWorks supervisor SPC2 Set point compensation with outdoor temperture probe
CMSC11 Serial communication module to BACnet-IP supervisor SCP4 Set point compensation with signal 0-10V
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
76
ACCESSORIES
SFSTR Disposal for inrush current reduction ECS ECOSHARE function for the automatic management of a
SPC2 Set point compensation with outdoor temperture probe group of units
SPC4 Set point compensation with signal 0-10V FANQE Electrical panal ventilation
PFCP Power factor correction capacitors (cosfi > 0.9)
KCCM - PAGE 46 PGCC Finned coil protection grilles and compressor compartment
2PM Hydropack load side with 2 pumps PSX Mains power supply
3PM Hydropack load side with 3 pumps RCMRX Remote control via microprocessor control
AMMX Spring antivibration mounts SCP4 Set point compensation with signal 0-10V
CCCA Copper / aluminium condenser coil with acrylic lining SPC2 Set point compensation with outdoor temperture probe
CMSC9 Serial communication module to Modbus supervisor ABU Flush hydraulic connections
CREFB Device for consumption reduction of the exernal section CCCA Copper / aluminium condenser coil with acrylic lining
ECOBREEZE fans CMSC10 Serial communication module to LonWorks supervisor
CREFO Device for consumption reduction of the exernal section CMSC11 Serial communication module to BACnet-IP supervisor
type on / off CSVX Couple of manual shut off valves
CSVX Couple of manual shut off valves FANQE Electrical panal ventilation
DML0-10 Demand limit with signal 0-10V IFWX Steel mesh strainer on the water side
DML4-20 Demand limit with signal 4-20mA MHP High and low pressure guages
ECS ECOSHARE function for the automatic management of a PFCP Power factor correction capacitors (cosfi > 0.9)
group of units PGFC Finned coil protection grill
PFCP Power factor correction capacitors (cosfi > 0.9) SDV Cutoff valve on compressor supply and return
PGCC Finned coil protection grilles and compressor compartment SFSTR Disposal for inrush current reductions
PGCCH Anti-hail protection grilles SPC1 Set point compensation with 4-20 mA signal
PSX Mains power supply SPC2 Set point compensation with outdoor temperture probe
RCMRX Remote control via microprocessor control SPC4 Set point compensation with signal 0-10V
REGBT Device for stepping of condensing coils KCNE ONLY
SFSTR2 Progressive compressor strt up device 1PUA High static pressure single pump
SPC1 Set point compensation with 4-20 mA signal 1PUB Low static pressure single pump
SPC2 Set point compensation with outdoor temperture probe CFSC Potential-free contacts for compressor status
SPC4 Set point compensation with signal 0-10V CMSC12 Serial communication module to BACnet MSTP supervisor
KRIX Kit to remote the control interface by microprocessor
KCFM - PAGE 48 PM Phase monitor
2PM Hydropack load side with 2 pumps SCP3 Set point compensation according to the outside enthalpy
3PM Hydropack load side with 3 pumps KCOE ONLY
AMMX Spring antivibration mounts 1PUA High static pressure single pump (sizes 182-402)
CBS Overload circuit breaker 1PUB Low static pressure single pump (sizes 182-402)
CCCA Copper / aluminium condenser coil with acrylic lining CLSCLR Free contacts compressor state and local / remote
CCCA1 Condensor coil with Energy Guard DCC Alumium management
CMSC10 Serial communication module to LonWorks supervisor CMSC9 Serial communication module to Modbus supervisor
CMSC11 Serial communication module to BACnet-IP supervisor CONTA2 Energy Meter
CMSC9 Serial communication module to Modbus supervisor DML0-10 Demand limit with signal 0-10V
CONTA2 Energy Meter DML4-20 Demand limit with signal 4-20mA
DML Demand limit
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
77
ACCESSORIES
ECS ECOSHARE function for the automatic management of a group SFSTR4N Disposal for inrush current reductions, for unit 400/3/50+N
of units SPCX Set point compensation with outdoor air temperature probe
MF2 Multi-function phase monitor KCGA ONLY
OHE Limit extension kit in heating up to -10 (W.B) SFSTR1 Disposal for inrush current reduction, for unit 230/1/50
PSX Mains power supply (sizes 17-41)
RCMRX Remote control via microprocessor control KCLA ONLY
STSOL Additional lifting brackets 3DHWX Three way valve for domestic hot water
ACS300X 300 litre domestic hot water storage tank (sizes 17-41)
KCRE - PAGE 52 ACS3SX 300 litre domestic hot water storage tank with solar coil
2PM Hydropack load side with 2 pumps ACS500X 500 litre domestic hot water storage tank (sizes 17-81)
3PM Hydropack load side with 3 pumps (sizes 90D-120D) ACS5SX 500 litre domestic hot water storage tank with solar coil
CSVX Couple of manual shut off valves CACSX Domestic hot water kit control
ABU Flush hydraulic connections KITERAX Electronic wall mounting room thermostat
CCCA Copper / aluminium condenser coil with acrylic lining KSAX 100 litre circuit breaker
CCCA1 Condensor coil with Energy Guard DCC Alumium KTFL1X 1" water side hose kit
AMMX Spring antivibration mounts KTFL2X 1 1/4" water side hose kit
MF2 Multi-function phase monitor KVMSP1X Radiant panels management kit with 1" connections
CONTA2 Energy Meter KVMSP2X Kit management of radiant panels with connections of 1 1/4"
RCMRX Remote control via microprocessor control SFSTR Disposal for inrush current reduction, for unit 230/1/50
(sizes 17-51)
PSX Mains power supply
CMSC10 Serial communication module to LonWorks supervisor
CMSC8 Serial communication module to BACnet supervisor
KCGW / KCHW - PAGE 58
AVIBX Anti vibration mount support
CMSC9 Serial communication module to Modbus supervisor
BACX BACnet serial communication module
SCP4 Set point compensation with signal 0-10V
CMMBX Serial communication module to supervisor (Modbus)
SPC2 Set point compensation with outdoor temperture probe
CMSC10 Serial communication module to LonWorks supervisor
ECS ECOSHARE function for the automatic management of a
group of units CMSC8 Serial communication module to BACnet supervisor
PFCP Power factor correction capacitors (cosfi > 0.9) CMSC9 Serial communication module to Modbus supervisor
SFSTR Disposal for inrush current reduction CMSLWX LonWorks serial communication module
FANQE Electrical panal ventilation IFWX Steel mesh strainer on the water side
MHP High and low pressure guages MF2 Multi-function phase monitor
SDV Cutoff valve on compressor supply and return MOBMAG Larger units
DSP Double set point PFCP Power factor correction capacitors (cosfi > 0.9)
RCTX Remote control
3WV Three way valve SPCX Set point compensation with outdoor air temperature probe
CMMBX Serial communication module to supervisor (Modbus) HYGC1 Cooling side hydronic unit with 1 ON/OFF pump
IVMSX Modulating valve source side HYGC2 Cooling side hydronic unit with 2 ON/OFF pump
IVWX Water side motorized valve HYGH1 Heating side hydronic unit with 1 ON/OFF pump
KDT3VX Double temperature control kit, set point compensation with HYGH2 Heating side hydronic unit with 2 ON/OFF pumps
4-20mA, 3 ways valve control VACSHX Heating side DHW switching valve
PBLC1X Service keypad (cable from 1.5 metres) VARYC VARYFLOW+ (cooling side 2 inverter pumps)
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
78
ACCESSORIES
VS2MC Cooling side two way modulating valve SDV Cutoff valve on compressor supply and return
VS2MH Heating side two way modulating valve SFSTR Disposal for inrush current reduction
VS3MC Cooling side three way modulating valve SPC1 Set point compensation with 4-20 mA signal
VS3MH Heating side three way modulating valve SPC2 Set point compensation with outdoor temperture probe
KCHW ONLY SPC4 Set point compensation with signal 0-10V
HYGS1 Source side hydronic unit with 1 ON/OFF pump VP Varypack
HYGS2 Source side hydronic unit with 2 ON/OFF pump
HYGU1 User side hydronic assembly with 1 ON/OFF pump KCGK - PAGE 64
HYGU2 User side hydronic assembly with 2 ON/OFF pump AMRX Rubber antivibration mounts
VACSUX User side DHW switching valve CFSC Potential-free contacts for compressor status
VARYS VARYFLOW+ (source side 2 inverter pumps) CMSC10 Serial communication module to LonWorks supervisor
VARYU VARYFLOW+ (user side 2 inverter pumps) CMSC8 Serial communication module to BACnet supervisor
VS2M Source side 2 way modulating valve CMSC9 Serial communication module to Modbus supervisor
VS3M Source side 3 way modulating valve IFWX Steel mesh strainer on the water side
MHP High and low pressure guages
KCGC - PAGE 62 PFCP Power factor correction capacitors (cosfi > 0.9)
2P1SB Hydropack with 2 pumps + 1 stand by PM Phase monitor
2P1SBS Hydropack source side with 2 pumps + 1 in stand by (sizes RCMRX Remote control via microprocessor control
65D-100D, 115D-180F) SDV Cutoff valve on compressor supply and return
2PM Hydropack load side with 2 pumps SFSTR Disposal for inrush current reductions
2PMS Hydropack source side with 2 pumps (sizes 65D-100D,
115D-180F) KCGK - PAGE 66
3PM Hydropack load side with 3 pumps AMRX Rubber antivibration mounts
3PMS Hydropack source side with 3 pumps CBS Overload circuit breaker
AMRX Rubber antivibration mounts CFSCE Potential free contacts for compressor status and enabling
CEHS Connection set exchanger with hydronic assemby (source CMSC10 Serial communication module to LonWorks supervisor
side)
CMSC11 Serial communication module to BACnet-IP supervisor
CEHU Connection set exchanger with hydronic assemby (user side)
CMSC9 Serial communication module to Modbus supervisor
CFSC Potential-free contacts for compressor status
CONTA2 Energy Meter
CMSC4 CAN/Modbus serial converter kit
DML0-10 Demand limit with signal 0-10V
CMSC5 CAN/BACnet serial converter kit
DML4-20 Demand limit with signal 4-20mA
CMSC6 CAN/LON WORKS serial converter kit
ECS ECOSHARE function for the automatic management of a
DSP Double set point group of units
DSPB Double set point for water low temperature EVE Electronic expansive valves
EHS Anti freeze electric heaters source side for hydronic IVMSX Modulating valve source side
assembly
PFCP Power factor correction capacitors (cosfi > 0.9)
EHU Anti freeze electric heaters user side for hydronic assembly
PSX Mains power supply
IFS2X Steel mesh strainer on source side
PVSX Water flow valve
IFUX Steel mesh strainer on the user side
RCMRX Remote control via microprocessor control
IVMSX Modulating valve source side
SFSTR2 Progressive compressor start up device
MHP High and low pressure guages
SPC1 Set point compensation with 4-20 mA signal
MSLX Master / salve operation
SPC2 Set point compensation with outdoor temperture probe
PFCP Power factor correction capacitors (cosfi > 0.9)
SPC4 Set point compensation with signal 0-10V
PM Phase monitor
PVSX Water flow valve
RCMRX Remote control via microprocessor control
SCP3 Set point compensation according to the outside enthalpy
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
79
ACCESSORIES
KCGL - PAGE 69
AMRX Rubber antivibration mounts
CBS Overload circuit breaker
CFSCE Potential free contacts for compressor status and enabling
CMSC10 Serial communication module to LonWorks supervisor
CMSC11 Serial communication module to BACnet-IP supervisor
CMSC9 Serial communication module to Modbus supervisor
CONTA2 Energy Meter
DML0-10 Demand limit with signal 0-10V
DML4-20 Demand limit with signal 4-20mA
ECS ECOSHARE function for the automatic management of a
group of units
PFCP Power factor correction capacitors (cosfi > 0.9)
PSX Mains power supply
RCMRX Remote control via microprocessor control
SFSTR2 Progressive compressor start up device
SPC1 Set point compensation with 4-20 mA signal
SPC2 Set point compensation with outdoor temperture probe
SPC4 Set point compensation with signal 0-10V
Fläkt Woods 9809GB 2016.07 Specifications are subject to alteration without notice
© Copyright 2016 Fläkt Woods Limited
9809GB 2016.07
Chillers Catalogue 2016
WE BRING WWW.FLAKTWOODS.CO.UK CHILLERS CATALOGUE | 9809GB
BETTER AIR ™
TO LIFE
With over a century of innovation and expertise to share with our
customers, Fläkt Woods is a global leader in Air Technology products
and solutions. We specialise in the design and manufacturing of a
wide range of products and solutions for Air Movement, Air Treatment,
Air Distribution, Air Management and Air Diffusion with focus on two
major benefits – Air Comfort and Fire Safety. With market presence
in 65 countries we are in a unique position to be a local supplier
and an international partner in our customer’s projects.
For Sales Call: 01206 222 555 for further information or use the contact details below for more information
Fläkt Woods Limited | Axial Way, Colchester, Essex, CO4 5ZD - AIR MOVEMENT - FANS CENTRE OF EXCELLENCE
After sales support | tel: 01202 835258 | email: support.uk@flaktwoods.com
email: salesuk@flaktwoods.com | website: www.flaktwoods.co.uk | twitter: @flaktwoodsuk