Professional Documents
Culture Documents
Should Be Lesser or Equal To Of: Size of Column Post
Should Be Lesser or Equal To Of: Size of Column Post
Should Be Lesser or Equal To Of: Size of Column Post
τp = 1.84 Mpa
Depth = 200 mm
No. of Post= 1
Size of Post = 200 mm
Perimeter = 800
Punching resistance = 293938.8 N
293.9388 KN
Maximum force on column 240.00 kN safe
depth of saddle stone = 600.00 mm
Size of saddle stone = 1000.00 mm
sses given in Table1 for compression perpenducular to the grain are also the permissible stresses for any length at end of members and fo
n 150 mm in length and located 75mm or more from the end of a member
ength at end of members and for bearing 150 mm or more in length
Seismic Weight calculation
Z = 0.36
I = 1.5
R = 3
dx = 12 m
dy = 10 m
ht = 3.4 m
Time period of building
Along X = 0.088335 sec
Along Y = 0.096766 sec
For this time period
Sa/gx =
Sa/gy =
Ahx = 0
Ahy = 0
Design Seismic Base Shear
Weight of structure
Vb = kN