Should Be Lesser or Equal To Of: Size of Column Post

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

Clause 7.4.

3 states depth should not exceed quarter of the section


Size of column post
depth d = 100 mm
max notch = 25 mm
Size of timber key lock
max width = 75 mm
should be lesser or equal to of 75 mm Clause 7.5.8.3 states
1 The permissible stresses given in Table1 for compres
2 for bearing less than 150 mm in length and located 7
Horizontal force
Fx = 240 kN
Fy = kN
Area of bearing = 21428.57 mm2
permissble bearing s= 11.2 Mpa
height of key = 285.7143 mm
Provide = 50 mm IS 883 recommends minimum 50 mm
Cantilever end moment
M = 80000 N-mm
Required thickness
t = 6.546537 mm
hence the required size is
width = 75 mm
depth = 50 mm
Saddle stone design
τp = 0.25(fck)0.5
for the stone (Sandstone)
fck= 54 Mpa (Bieniawski et.al (1974))

τp = 1.84 Mpa
Depth = 200 mm
No. of Post= 1
Size of Post = 200 mm
Perimeter = 800
Punching resistance = 293938.8 N
293.9388 KN
Maximum force on column 240.00 kN safe
depth of saddle stone = 600.00 mm
Size of saddle stone = 1000.00 mm
sses given in Table1 for compression perpenducular to the grain are also the permissible stresses for any length at end of members and fo
n 150 mm in length and located 75mm or more from the end of a member
ength at end of members and for bearing 150 mm or more in length
Seismic Weight calculation
Z = 0.36
I = 1.5
R = 3
dx = 12 m
dy = 10 m
ht = 3.4 m
Time period of building
Along X = 0.088335 sec
Along Y = 0.096766 sec
For this time period
Sa/gx =
Sa/gy =
Ahx = 0
Ahy = 0
Design Seismic Base Shear
Weight of structure
Vb = kN

You might also like