Using A 6-2E/TP-12 Test Point Adaptor in Network Amplifiers
Using A 6-2E/TP-12 Test Point Adaptor in Network Amplifiers
1. Replace the jumper or equalizer in the "Distribution Slope Equalizer" (or Secondary Output
Equalizer) position with the 6-2E/TP-12 (as illustrated below). With the testpoint plugged in
there is RF continuity to the feeder ports. Please note that network amplifiers that are model
"B" or "C" have -30 dB directional coupler test points already built into their circuit boards.
The 6-2E/TP12 is not recommended for use with "B" amplifiers.
2. When the testpoint replaces an equalizer, the measured output does not include the loss or
the tilt of the equalizer. When using the 6-2E/TP-12 to verify or set output levels on a
feeder/secondary port, be sure to compensate for the loss of the equalizer.
3. After using the testpoint to verify output, put the original jumper or equalizer back in place.
The following is the Test Point Value Table for Trunk Network Ampifiers, and for High Gain
Global Network Amplifiers (550 MHz, 600 MHz, 750 MHz, excludes loss from equalizers):