Scott B.

Moore Construction
Property Inspection Report
Cover Page

2829 Barclay Rd., Medford, OR 97504


Inspection prepared for: Linda Holland
Date of Inspection: 6/3/2019 Time: 9am
Age of Home: 36 Size: 1646
Weather: 65 Degrees and clear.

Inspector: Scott B. Moore


License # CCB 209211 OCHI # 1543
240 Willow Bend Way, Central Point, OR 97502
Phone: 541-621-1793
Email: scottbmooreconstruction@gmail.com
http://www.roguevalleyhomeinspections.com
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Report Summary
Report Summary
The summary below consists of potentially significant findings. These findings can be a safety
hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra
attention to. The summary is not a complete listing of all the findings in the report, and reflects the
opinion of the inspector. Please review all of the pages of the report as the summary alone does not
explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I
recommend obtaining a copy of all receipts, warranties and permits for the work done.
Interior Areas
Page 8 Item: 9 Smoke Detectors • **CARBON MONOXIDE DETECTORS**
• No CO detector present at time of inspection. CO detectors
are required whenever there is a combustible source in the
home or an attached garage. Recommend installation of
adequate detector within 15 feet of each bedroom as per
industry standards before closing.
Page 8 Item: 10 Stairs & Handrail • Very loose newel posts observed at the top of the stairs.
Recommend evaluation by a licensed contractor and review
for costs of repairs as needed before closing.
Bathroom
Page 20 Item: 7 GFCI • No GFCI -
Electrical outlets in this bathroom appeared to be in
serviceable condition at the time of the inspection but had no
Ground Fault Circuit Interrupter (GFCI) protection.
Although this condition may have been commonly considered
safe or acceptable at the time the home was originally
constructed, as general knowledge of safe building practices
has improved with the passage of time, building standards
have changed to reflect current understanding.
Consider having GFCI protection installed as a safety
precaution for outlets within 6 feet of a plumbing fixture.
This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets
2. Replacing the outlet in this bathroom circuit which is
nearest the main electrical service panel with a GFCI outlet.
3. Replacing the breaker currently protecting the electrical
circuit which contains these bathroom outlets with a GFCI
breaker.
This condition is typical at other required locations as well.
Recommend evaluation by a licensed electrical contractor and
review for costs of upgrades to current industry standards
before closing.
Page 23 Item: 20 Window Condition • Evidence of condensation observed. This is an indication of
failed seals between the dual glazing of the window. This
condition is typical in bathroom 3 and the laundry room as
well. Recommend evaluation by a qualified window company
and review for costs of replacement before closing.
Bathroom 2
Page 25 Item: 7 GFCI • GFCI did not respond to test. Recommend review for costs
of replacement before closing.
Bathoom 3
Page 30 Item: 7 GFCI • No GFCI protection present, suggest installing GFCI
protected receptacles for safety.

Page 1 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Page 32 Item: 20 Window Condition • Evidence of condensation observed. Recommend review for
costs of replacement before closing.
Laundry
Page 41 Item: 16 Window Condition • Evidence of condensation observed. Recommend review for
costs of replacement before closing.
Garage
Page 49 Item: 7 GFCI • No GFCI protection present, suggest installing GFCI
protected receptacles for safety.
Page 49 Item: 14 Garage Door's • No eye beam system present on the east side door.
Reverse Status Recommend evaluation by a qualified door technician and
review for costs of installation as per industry standards
before closing.
Roof
Page 51 Item: 1 Roof Condition • Moss on roof. This can lead to the premature failure of the
roof and subsequent leaks. Recommend treating moss during
its growing season (wet months) with a moss killer. For
information on various moss treatment products and their pros
and cons, visit
http://bryophytes.science.oregonstate.edu/page24.htm.
Page 53 Item: 3 Chimney • Severely damage paint observed. Recommend evaluation
by a licensed contractor and review for costs of repairs before
closing.
Page 54 Item: 7 Gutter • Evidence of leaks and rust observed under the south side
gutters. Recommend evaluation by a qualified gutter
technician and review for costs of repair/replacement as
needed before closing.
Exterior Areas
Page 58 Item: 2 Window Condition • Most of the components appeared in satisfactory condition
at time of inspection. Recommend review for costs of
replacements as needed before closing.
Page 60 Item: 5 Exterior Paint • Peeling paint observed, suggest scraping and painting as
necessary.
Grounds
Page 61 Item: 3 Vegetation • Prune or remove any plants that are in contact or proximity
Observations to home to eliminate pathways of wood destroying insects.
• Tree limbs within 10 feet of roof should be trimmed away to
provide air and sunlight to roof, while minimizing debris &
dampness.
• Trim trees that are in contact or proximity to home, as
branches can abrade roofing or siding.
Page 62 Item: 4 Gate Condition • The east side gate is in disrepair. Recommend
repair/replacement before occupancy.
Page 62 Item: 5 Patio and Porch • Severe settlement observed under the east corner of the
Deck front deck. Recommend invasive evaluation by a licensed
contractor and review for costs of repairs as needed before
closing.
Page 63 Item: 8 GFCI • No GFCI protection observed in the plug at the back deck
location. Recommend review for costs of upgrade to current
industry standards before closing.

Page 2 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Page 65 Item: 17 Fence Condition • **FENCING**


• Fence leaning in areas mostly on the east side of the home.
Recommend review for costs of repairs as needed before
closing.
Foundation
Page 66 Item: 7 Access Panel • Limited inspection from the access area only due to standing
water in the crawlspace. Common condition for this area of
town.

Page 3 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire
Inspection Report. Call us after you have reviewed your report, so we can go over any questions
you may have. Remember, when the inspection is completed and the report is delivered, we are still
available to you for any questions you may have, throughout the entire closing process.
Properties being inspected do not "Pass" or "Fail.” - The following report is based on an inspection
of the visible portion of the structure; inspection may be limited by vegetation and possessions.
Depending upon the age of the property, some items like GFI outlets may not be installed; this
report will focus on safety and function, not current code. This report identifies specific non-
code, non-cosmetic concerns that the inspector feels may need further investigation or repair.
For your safety and liability purposes, we recommend that licensed contractors evaluate and repair
any critical concerns and defects. Note that this report is a snapshot in time. We recommend
that you or your representative carry out a final walk-through inspection immediately before
closing to check the condition of the property, using this report as a guide.

Page 4 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Inspection Details
1. Attendance
In Attendance: Client not present
2. Home Type
Home Type: Single Family Home
3. Occupancy
Occupancy: Occupied - Furnished: Heavy volume of personal and household
items observed. • The utilities were on at the time of inspection. • Access to
some items such as: electrical outlets/receptacles, windows, wall/floor
surfaces, and cabinet interiors may be restricted by furniture or personal
belongings. Any such items are excluded from this inspection report.

Page 5 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Interior Areas
The Interior section covers areas of the house that are not considered part of the Bathrooms,
Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of
hallways, foyer, and other open areas. Within these areas the inspector is performing a visual
inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal
items in the structure may prevent the inspector from viewing all areas on the interior.

The inspector does not usually test for mold or other hazardous materials. A qualified expert should
be consulted if you would like further testing.
1. Bar
Good Fair Poor N/A None

General Condition General Condition

General Condition
2. Cabinets
Good Fair Poor N/A None

Page 6 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

General Condition General Condition


5. Door Bell
Good Fair Poor N/A None
Observations:
X • Operated normally when tested.

6. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. Electrical
Good Fair Poor N/A None
Observations:
X • The majority of grounded receptacles , were tested and found to be wired
correctly.
• Some outlets not accessible due to furniture and or stored personal items.
8. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

Page 7 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

9. Smoke Detectors
Good Fair Poor N/A None
Observations:
X • **SMOKE DETECTORS**
• Operated when tested.
• **CARBON MONOXIDE DETECTORS**
• No CO detector present at time of inspection. CO detectors are required
whenever there is a combustible source in the home or an attached garage.
Recommend installation of adequate detector within 15 feet of each bedroom
as per industry standards before closing.
10. Stairs & Handrail
Good Fair Poor N/A None
Observations:
X • Very loose newel posts observed at the top of the stairs. Recommend
evaluation by a licensed contractor and review for costs of repairs as needed
before closing.

General Condition General Condition

Loose
11. Window-Wall AC or Heat
Good Fair Poor N/A None

Page 8 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

12. Ceiling Condition


Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
13. Patio Doors
Good Fair Poor N/A None
Observations:
X • **Sliding Patio Doors**
• The sliding patio door was functional during the inspection.
14. Screen Doors
Good Fair Poor N/A None
Observations:
X • Sliding door screen is functional.

15. Wall Condition


Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.
16. Fireplace
Good Fair Poor N/A None
Materials: Living Room
X Observations:
• **Wood Fireplaces**
• The wood stove has been removed.
17. Window Condition
Good Fair Poor N/A None
Materials: Aluminum framed single hung window noted.
X Observations:
• Operated windows appeared functional, at time of inspection
• Some not accessible.
• Missing screens observed.

Page 9 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Bedrooms
The main area of inspection in the bedrooms is the structural system. This means that all walls,
ceilings and floors will be inspected. Doors and windows will also be investigated for damage and
normal operation. Personal items in the bedroom may prevent all areas to be inspected as the
inspector will not move personal items.
1. Locations
Locations: Master
2. Cabinets
Good Fair Poor N/A None

General Condition General Condition


3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

Page 10 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition
5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • The majority of grounded receptacles , were tested and found to be wired
correctly.
• Some outlets not accessible due to furniture and or stored personal items.
7. Fireplace
Good Fair Poor N/A None

8. Floor Condition
Good Fair Poor N/A None
Flooring Types: Carpet is noted.
X Observations:
• No concerns in this area.

General Condition

Page 11 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

9. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

10. Smoke Detectors


Good Fair Poor N/A None
Observations:
X • **Smoke Detectors**
• The smoke detectors operated during the inspection.
11. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.
12. Window-Wall AC or Heat
Good Fair Poor N/A None

13. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection.
14. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
15. Patio Doors
Good Fair Poor N/A None
Observations:
X • There are no patio doors present in this room.

16. Screen Doors


Good Fair Poor N/A None

Page 12 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Bedroom 2
1. Locations
Locations: Upper level left.
2. Cabinets
Good Fair Poor N/A None

General Condition General Condition


3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

General Condition

Page 13 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • The majority of grounded receptacles , were tested and found to be wired
correctly.
• Some outlets not accessible due to furniture and or stored personal items.
7. Fireplace
Good Fair Poor N/A None

8. Floor Condition
Good Fair Poor N/A None
Flooring Types: Carpet is noted.
X Observations:
• No concerns in this area.

General Condition
9. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

10. Smoke Detectors


Good Fair Poor N/A None
Observations:
X • **Smoke Detectors**
• The smoke detectors operated during the inspection.
11. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.

Page 14 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

12. Window-Wall AC or Heat


Good Fair Poor N/A None

13. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection.
14. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
15. Patio Doors
Good Fair Poor N/A None
Observations:
X • There are no patio doors present in this room.

16. Screen Doors


Good Fair Poor N/A None

Page 15 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Bedroom 3
1. Locations
Locations: Upper level right.
2. Cabinets
Good Fair Poor N/A None

General Condition General Condition


3. Ceiling Fans
Good Fair Poor N/A None
Observations:
X • None present.

4. Closets
Good Fair Poor N/A None
Observations:
X • The closet is in serviceable condition.

General Condition

Page 16 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • The majority of grounded receptacles , were tested and found to be wired
correctly.
• Some outlets not accessible due to furniture and or stored personal items.
7. Fireplace
Good Fair Poor N/A None

8. Floor Condition
Good Fair Poor N/A None
Flooring Types: Carpet is noted.
X Observations:
• No concerns in this area.

General Condition
9. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

10. Smoke Detectors


Good Fair Poor N/A None
Observations:
X • **Smoke Detectors**
• The smoke detectors operated during the inspection.
11. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.

Page 17 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

12. Window-Wall AC or Heat


Good Fair Poor N/A None

13. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection.
14. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
15. Patio Doors
Good Fair Poor N/A None
Observations:
X • There are no patio doors present in this room.

16. Screen Doors


Good Fair Poor N/A None

Page 18 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Bathroom
Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets.
Because of all the plumbing involved it is an important area of the house to look over. Moisture in the
air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home
inspector will identify as many issues as possible but some problems may be undetectable due to
problems within the walls or under the flooring..
1. Locations
Locations: Master Bathroom
2. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

General Condition
3. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
4. Counters
Good Fair Poor N/A None
Observations:
X • Solid Surface tops noted.
• There is normal wear noted for the age of the counter tops.

Page 19 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition
5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI -
Electrical outlets in this bathroom appeared to be in serviceable condition at
the time of the inspection but had no Ground Fault Circuit Interrupter (GFCI)
protection.
Although this condition may have been commonly considered safe or
acceptable at the time the home was originally constructed, as general
knowledge of safe building practices has improved with the passage of time,
building standards have changed to reflect current understanding.
Consider having GFCI protection installed as a safety precaution for outlets
within 6 feet of a plumbing fixture.
This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets
2. Replacing the outlet in this bathroom circuit which is nearest the main
electrical service panel with a GFCI outlet.
3. Replacing the breaker currently protecting the electrical circuit which
contains these bathroom outlets with a GFCI breaker.
This condition is typical at other required locations as well. Recommend
evaluation by a licensed electrical contractor and review for costs of
upgrades to current industry standards before closing.
8. Exhaust Fan
Good Fair Poor N/A None
Observations:
X • The bath fan was operated and no issues were found.

Page 20 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

9. Floor Condition
Good Fair Poor N/A None
Materials: Sheet vinyl flooring is noted.
X Observations:
• No concerns in this area.

General Condition
10. Heating
Good Fair Poor N/A None
Observations:
X • Central heating and cooling noted in this room. At the time of the
inspection, all appeared to be functioning and in serviceable condition.
• Heat lamp mounted in the ceiling noted in this room. At the time of the
inspection, it appeared to be functioning and in serviceable condition.
11. Mirrors
Good Fair Poor N/A None
Observations:
X • The mirror is adequate.

12. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

13. Security Bars


Good Fair Poor N/A None

14. Showers
Good Fair Poor N/A None
Observations:
X • **SHOWER BASE**
• No deficiencies observed.
• **SHOWER FAUCET**
• No deficiencies observed.

Page 21 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

15. Shower Walls


Good Fair Poor N/A None
Observations:
X • **MATERIALS**
• Cultured Marble noted.
• **OBSERVATIONS**
• Appeared functional, staining observed.

General Condition
16. Bath Tubs
Good Fair Poor N/A None
Observations:
X • Appeared functional, staining observed.

General Condition
17. Enclosure
Good Fair Poor N/A None
Observations:
X • The shower enclosure was functional at the time of the inspection.

Page 22 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

18. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.
• Broken stopper observed.

General Condition
19. Toilets
Good Fair Poor N/A None
Observations:
X • Operated when tested. No deficiencies noted.

20. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Evidence of condensation observed. This is an indication of failed seals
between the dual glazing of the window. This condition is typical in bathroom
3 and the laundry room as well. Recommend evaluation by a qualified
window company and review for costs of replacement before closing.

Page 23 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Bathroom 2
1. Locations
Locations: Full bath upper level.
2. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

General Condition
3. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
4. Counters
Good Fair Poor N/A None
Observations:
X • Plastic laminate tops noted.
• There is normal wear noted for the age of the counter tops.

General Condition

Page 24 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. GFCI
Good Fair Poor N/A None
Observations:
X • GFCI did not respond to test. Recommend review for costs of replacement
before closing.
8. Exhaust Fan
Good Fair Poor N/A None
Observations:
X • The bath fan was operated and no issues were found.

9. Floor Condition
Good Fair Poor N/A None
Materials: Sheet vinyl flooring is noted.
X Observations:
• No concerns in this area.

General Condition
10. Heating
Good Fair Poor N/A None
Observations:
X • Central heating and cooling noted in this room. At the time of the
inspection, all appeared to be functioning and in serviceable condition.
• Heat lamp mounted in the ceiling noted in this room. At the time of the
inspection, it appeared to be functioning and in serviceable condition.
11. Mirrors
Good Fair Poor N/A None
Observations:
X • The mirror is adequate.

Page 25 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

12. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

13. Security Bars


Good Fair Poor N/A None

14. Showers
Good Fair Poor N/A None
Observations:
X • **SHOWER BASE**
• No deficiencies observed.
• **SHOWER FAUCET**
• No deficiencies observed.
15. Shower Walls
Good Fair Poor N/A None
Observations:
X • **MATERIALS**
• Fiberglass surround noted.
• **OBSERVATIONS**
• Appeared functional, staining observed.

General Condition
16. Bath Tubs
Good Fair Poor N/A None
Observations:
X • Appeared functional, staining observed.

Page 26 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition
17. Enclosure
Good Fair Poor N/A None
Observations:
X • Curtain present at the shower enclosure.

18. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.

General Condition
19. Toilets
Good Fair Poor N/A None
Observations:
X • Operated when tested. Appeared functional, at time of inspection - except
as noted.

Page 27 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

20. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Operated windows appeared functional, at time of inspection

Page 28 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Bathoom 3
1. Locations
Locations: Half bathroom lower level.
2. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

General Condition
3. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
4. Counters
Good Fair Poor N/A None
Observations:
X • Plastic laminate tops noted.
• There is normal wear noted for the age of the counter tops.
• Some of the areas not visible due to stored personal items.

General Condition
Page 29 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

5. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

6. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

7. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI protection present, suggest installing GFCI protected receptacles
for safety.
8. Exhaust Fan
Good Fair Poor N/A None
Observations:
X • The bath fan was operated and no issues were found.

9. Floor Condition
Good Fair Poor N/A None
Materials: Hardwood flooring is noted.
X Observations:
• No concerns in this area.

General Condition
10. Heating
Good Fair Poor N/A None

11. Mirrors
Good Fair Poor N/A None
Observations:
X • The mirror is adequate.

12. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

Page 30 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

13. Security Bars


Good Fair Poor N/A None

14. Showers
Good Fair Poor N/A None

15. Shower Walls


Good Fair Poor N/A None

16. Bath Tubs


Good Fair Poor N/A None

17. Enclosure
Good Fair Poor N/A None

18. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.

General Condition
19. Toilets
Good Fair Poor N/A None
Observations:
X • Operated when tested. No deficiencies noted.

Page 31 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

20. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Evidence of condensation observed. Recommend review for costs of
replacement before closing.

Page 32 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Kitchen
The kitchen is used for food preparation and often for entertainment. Kitchens typically include a
stove, dishwasher, sink and other appliances.
1. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional at time of inspection.

General Condition General Condition

General Condition
2. Counters
Good Fair Poor N/A None
Observations:
X • Granite tops noted.
• There is normal wear noted for the age of the counter tops.
• Some of the areas not visible due to stored personal items.

Page 33 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition
3. Dishwasher
Good Fair Poor N/A None
Observations:
X • Dishwasher was operational at the time of inspection. Dishwashers most
commonly fail internally at the pump, motor or seals. We do not disassemble
these units to inspect these components. We recommend you operate this
unit prior to closing.
4. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

5. Garbage Disposal
Good Fair Poor N/A None
Observations:
X • Operated - appeared functional at time of inspection.

6. Microwave
Good Fair Poor N/A None
Observations:
X • Built-in microwave ovens are tested using normal operating controls. Unit
was tested and appeared to be serviceable at time of inspection. Leak and/or
efficiency testing is beyond the scope of this inspection. If concerned, client
should seek further review by qualified technician prior to closing.
7. Cook top condition
Good Fair Poor N/A None
Observations:
X • Gas cook top noted.
• All burners responded to controls.

Page 34 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition
8. Oven & Range
Good Fair Poor N/A None
Observations:
X • Oven: gas burners
• All burners responded to controls.

General Condition
9. Sinks
Good Fair Poor N/A None
Observations:
X • **DRAINS**
• No deficiencies observed.
• **SUPPLY**
• No deficiencies observed.

Page 35 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition General Condition


10. Drinking Fountain
Good Fair Poor N/A None
Observations:
X • There was no drinking fountain present in this kitchen.

11. Spray Wand


Good Fair Poor N/A None
Observations:
X • The spray wand was operated and was functional.

12. Hot Water Dispenser


Good Fair Poor N/A None

13. Soap Dispenser


Good Fair Poor N/A None
Observations:
X • There was no soap present in the dispenser, could not test.

14. Trash Compactor


Good Fair Poor N/A None

15. Vent Condition


Good Fair Poor N/A None
Materials: Exterior Vented
X Observations:
• Central ventilation system is present.
• Exhaust fan is operable.
16. Window Condition
Good Fair Poor N/A None

17. Floor Condition


Good Fair Poor N/A None
Materials: Hardwood flooring is noted.
X Observations:
• No concerns in this area.
Page 36 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition
18. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.

19. Ceiling Condition


Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
20. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

21. Patio Doors


Good Fair Poor N/A None
Observations:
X • **Sliding Patio Doors**
• The sliding patio door was functional during the inspection.
22. Screen Doors
Good Fair Poor N/A None
Observations:
X • Sliding door screen is functional.

23. Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

24. GFCI
Good Fair Poor N/A None
Observations:
X • GFCI in place and operational.

Page 37 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

25. Wall Condition


Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
• No concerns in this area.

Page 38 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Laundry
1. Locations
Locations: Of the kitchen area.
2. Cabinets
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

General Condition
3. Counters
Good Fair Poor N/A None

4. Dryer Vent
Good Fair Poor N/A None
Observations:
X • The dryer vent is functional.

5. Electrical
Good Fair Poor N/A None
Observations:
X • The dryer plug was tested and is functional.

6. GFCI
Good Fair Poor N/A None

7. Exhaust Fan
Good Fair Poor N/A None
Observations:
X • None present.

8. Gas Valves
Good Fair Poor N/A None
Observations:
X • No gas present.

Page 39 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

9. Wash Basin
Good Fair Poor N/A None

10. Floor Condition


Good Fair Poor N/A None
Materials: Vinyl squares (tiles) are noted
X Observations:
• No concerns in this area.

General Condition
11. Plumbing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional at time of inspection.
• Some not accessible.
12. Wall Condition
Good Fair Poor N/A None
Materials: Drywall walls noted.
X Observations:
• Some areas not accessible due to stored personal items.
13. Ceiling Condition
Good Fair Poor N/A None
Materials: There are drywall ceilings noted.
X Observations:
• No concerns in this area.
14. Security Bars
Good Fair Poor N/A None
Observations:
X • No security bars are present in this room.

15. Doors
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

Page 40 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

16. Window Condition


Good Fair Poor N/A None
Materials: Aluminum framed sliding window noted.
X Observations:
• Evidence of condensation observed. Recommend review for costs of
replacement before closing.

Condensation

Page 41 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Heat/AC
The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the
climate control system for the structure. The goal of these systems is to keep the occupants at a
comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at
a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be
powered by other sources such as butane, oil, propane, solar panels, or wood.

The inspector will usually test the heating and air conditioner using the thermostat or other controls.
For a more thorough investigation of the system please contact a licensed HVAC service person.
1. Heater Condition
Good Fair Poor N/A None
Materials: Location: • The furnace is located in the garage
X Materials: Gas fired forced hot air.
Observations:
• The average heat output at time of inspection was 95 degrees. This is a 25
degree variance from the ambient room temperature.

General Condition
2. Heater Base
Good Fair Poor N/A None
Observations:
X • The heater base appears to be functional.

3. Enclosure
Good Fair Poor N/A None
Observations:
X • Normal surface rust/corrosion observed, no signs of flaking or excessive
deterioration noted.
4. Venting
Good Fair Poor N/A None
Observations:
X • **VENTING MATERIALS**
• Plastic - PVC vent noted.
• **VENTING OBSERVATIONS**
• The visible portions of the vent pipes appeared functional.
5. Gas Valves
Good Fair Poor N/A None
Observations:
X • Gas shut off valves were present and functional.

Page 42 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

6. Refrigerant Lines
Good Fair Poor N/A None
Observations:
X • No defects found.

7. AC Compress Condition
Good Fair Poor N/A None
Compressor Type: Electric
X Location: The compressor is located on the exterior south.
Observations:
• The typical temperature differential split between supply and return air in an
air conditioner of this type is 15 - 20 degrees F. This system responded and
achieved an acceptable differential temperature of 16-17 degrees F.
• This unit was manufactured in April of 1997.
• Annual HVAC service contract is recommended.

General Condition
8. Air Supply
Good Fair Poor N/A None
Observations:
X • The return air supply system appears to be functional.

9. Registers
Good Fair Poor N/A None

10. Filters
Good Fair Poor N/A None
Location: Located inside heater cabinet.
X Observations:
• Electronic filter observed.
• Electronic air filters are beyond the scope of a home inspection.
11. Thermostats
Good Fair Poor N/A None
Observations:
X • Digital - programmable type.
• Functional at the time of inspection.
• Thermostats are not checked for calibration or timed functions.

Page 43 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Water Heater
1. Base
Good Fair Poor N/A None
Observations:
X • The water heater base is functional.

2. Heater Enclosure
Good Fair Poor N/A None
Observations:
X • The water heater enclosure is functional.

3. Combusion
Good Fair Poor N/A None
Observations:
X • The combustion chamber appears to in functional condition.

4. Venting
Good Fair Poor N/A None

5. Water Heater Condition


Good Fair Poor N/A None
Heater Type: Gas
X Location: The heater is located in the garage.
Observations:
• This water heater was manufactured in June of 2006.
• Tank appears to be in satisfactory condition -- no concerns.

General Condition
6. TPRV
Good Fair Poor N/A None
Observations:
X • Temperature Pressure Release (TPR) valve and discharge pipe --
functional and in satisfactory condition.
7. Number Of Gallons
Good Fair Poor N/A None
Observations:
X • 50 gallons

Page 44 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

8. Gas Valve
Good Fair Poor N/A None
Observations:
X • Appears functional.

9. Plumbing
Good Fair Poor N/A None
Materials: Copper
X Observations:
• No deficiencies observed at the visible portions of the supply piping.
10. Overflow Condition
Good Fair Poor N/A None
Materials: Copper
X Observations:
• Appears to be in satisfactory condition -- no concerns.
11. Strapping
Good Fair Poor N/A None
Observations:
X • The water heater is strapped to current code.

Page 45 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Electrical
1. Electrical Panel
Good Fair Poor N/A None
Location: Main Location: • Panel box located in garage.
X Observations:
• No major system safety or function concerns noted at time of inspection at
main panel box.
• Access to panel box blocked; interior not evaluated due to safety issues.

General Condition General Condition


2. Main Amp Breaker
Good Fair Poor N/A None
Observations:
X • 200 amp

3. Breakers in off position


Good Fair Poor N/A None

4. Cable Feeds
Good Fair Poor N/A None
Observations:
X • There is an underground service lateral noted.

5. Breakers
Good Fair Poor N/A None
Materials: Copper non-metallic sheathed cable noted.
X Observations:
• All of the circuit breakers appeared serviceable.
6. Fuses
Good Fair Poor N/A None

Page 46 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Garage
1. Roof Condition
Good Fair Poor N/A None
Materials: Roofing is the same as main structure.
X Materials: Composition shingles noted.
Observations:
• No major system safety or function concerns noted at time of inspection.
2. Walls
Good Fair Poor N/A None
Observations:
X • Appeared satisfactory, at time of inspection.
• Personal items in garage block complete inspection of all floor, wall and
ceiling areas.

General Condition General Condition

General Condition
3. Anchor Bolts
Good Fair Poor N/A None
Observations:
X • The anchor bolts were not visible, obscured by drywall.

Page 47 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

4. Floor Condition
Good Fair Poor N/A None
Materials: Bare concrete floors noted.
X Observations:
• Common cracks noted.

General Condition
5. Rafters & Ceiling
Good Fair Poor N/A None
Observations:
X • Engineered wood roof truss framing noted.
• No deficiencies observed at the visible portions of the roof structure.

Typical Typical
6. Electrical
Good Fair Poor N/A None
Observations:
X • Some outlets not accessible due to furniture and or stored personal items.

7. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI protection present, suggest installing GFCI protected receptacles
for safety.

Page 48 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

8. 240 Volt
Good Fair Poor N/A None
Observations:
X • There are no 240 volt outlets visible in this room.

9. Exterior Door
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

10. Fire Door


Good Fair Poor N/A None
Observations:
X • Appeared satisfactory and functional, at time of inspection.

11. Garage Door Condition


Good Fair Poor N/A None
Materials: Two 8' x 7' sectional roll up doors observed.
X Observations:
• No deficiencies observed.

General Condition General Condition


12. Garage Door Parts
Good Fair Poor N/A None
Observations:
X • The garage doors appeared functional during the inspection.

13. Garage Opener Status


Good Fair Poor N/A None
Observations:
X • Chain drive openers noted.
• Appeared functional using normal controls, at time of inspection.
14. Garage Door's Reverse Status
Good Fair Poor N/A None
Observations:
X • Eye beam system present and operating on the west side door.
• No eye beam system present on the east side door. Recommend
evaluation by a qualified door technician and review for costs of installation
as per industry standards before closing.

Page 49 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

15. Ventilation
Good Fair Poor N/A None

16. Vent Screens


Good Fair Poor N/A None

17. Cabinets
Good Fair Poor N/A None

18. Counters
Good Fair Poor N/A None

19. Wash Basin


Good Fair Poor N/A None

Page 50 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Roof
1. Roof Condition
Good Fair Poor N/A None
Materials: Roof was visually inspected from accessible points on the interior
X and/or exterior. If a roof is too high, is too steep, is wet, or is composed of
materials which can be damaged if walked upon, the roof is not mounted or
some areas not walked upon. Therefore, client is advised that this is a limited
review and a licensed roofer should be contacted if a more detailed report is
desired.
Materials: Composition shingles noted.
Observations:
• Moderate wear and loss of granules observed throughout the roof.
Common condition for the age of the shingles. With normal maintenence we
would estimate 10+ years of service life remaining in these shingles.
• Moss on roof. This can lead to the premature failure of the roof and
subsequent leaks. Recommend treating moss during its growing season (wet
months) with a moss killer. For information on various moss treatment
products and their pros and cons, visit
http://bryophytes.science.oregonstate.edu/page24.htm.

General Condition General Condition

General Condition General Condition

Page 51 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition Typical

Moss
2. Flashing
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional.

Page 52 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition General Condition


3. Chimney
Good Fair Poor N/A None
Observations:
X • Severely damage paint observed. Recommend evaluation by a licensed
contractor and review for costs of repairs before closing.

Peeling
4. Sky Lights
Good Fair Poor N/A None

5. Spark Arrestor
Good Fair Poor N/A None

6. Vent Caps
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional.

Page 53 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition General Condition


7. Gutter
Good Fair Poor N/A None
Observations:
X • Evidence of leaks and rust observed under the south side gutters.
Recommend evaluation by a qualified gutter technician and review for costs
of repair/replacement as needed before closing.

Rust

Page 54 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Attic
1. Access
Good Fair Poor N/A None
Observations:
X • **Location of access**
• Scuttle Hole located in bedroom 3 closet.
• **Access Observations**
• Entering attics that are heavily insulated can cause damage to the
insulation and attic framing. Attics with deep insulation cannot be safely
inspected due to limited visibility of the framing members upon which the
inspector must walk. In such cases,the attic is only partially accessed,
thereby limiting the review of the attic area from the hatch area only.

Typical
2. Structure
Good Fair Poor N/A None
Observations:
X • No deficiencies observed in the visible portions of the roof structure.

Typical Typical

Page 55 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Typical
3. Ventilation
Good Fair Poor N/A None
Observations:
X • Under eave soffit inlet vents noted.
• Gable louver vents noted.
• Fixed, roof-field exhaust vent noted.
4. Vent Screens
Good Fair Poor N/A None
Observations:
X • Vent screens noted as functional.

5. Duct Work
Good Fair Poor N/A None
Observations:
X • Appeared adequate and functional.

Typical
6. Electrical
Good Fair Poor N/A None
Observations:
X • Most areas not accessible due to insulation.

Page 56 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

7. Attic Plumbing
Good Fair Poor N/A None
Observations:
X • ABS plumbing vents
• No deficiencies noted in plumbing vent piping.
8. Insulation Condition
Good Fair Poor N/A None
Materials: Loose fill insulation noted.
X Depth: Insulation averages about 14-16 inches in depth
Observations:
• Insulation appears adequate. R-38 value observed.
9. Chimney
Good Fair Poor N/A None

10. Exhaust Vent


Good Fair Poor N/A None
Observations:
X • Could not access.

Page 57 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Exterior Areas
1. Doors
Good Fair Poor N/A None
Observations:
X • Appeared in functional and in satisfactory condition, at time of inspection.

Typical Typical

Typical
2. Window Condition
Good Fair Poor N/A None
Observations:
X • Most of the components appeared in satisfactory condition at time of
inspection. Recommend review for costs of replacements as needed before
closing.

Page 58 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Typical Typical

Typical
3. Siding Condition
Good Fair Poor N/A None
Materials: Wood siding, wood frame construction, concrete / block foundation
X Observations:
• T1-11 wood siding observed. Typical wear for the age of the structure.
• No major system safety or function concerns noted at time of inspection.

Page 59 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

T1-11
4. Eaves & Facia
Good Fair Poor N/A None
Observations:
X • The eaves at the home appeared to be in serviceable condition at the time
of the inspection.

Typical
5. Exterior Paint
Good Fair Poor N/A None
Observations:
X • Peeling paint observed, suggest scraping and painting as necessary.

6. Stucco
Good Fair Poor N/A None

Page 60 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Grounds
1. Driveway and Walkway Condition
Good Fair Poor N/A None
Materials: Concrete driveway noted. • Concrete sidewalk noted.
X Observations:
• Driveway and sidewalk in good shape for age and wear. No deficiencies
noted.

General Condition
2. Grading
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

3. Vegetation Observations
Good Fair Poor N/A None
Observations:
X • Maintenance Tip: When landscaping, keep plants, even at full growth, at
least a foot (preferably 18 inches) from house siding and windows. Keep
trees away from foundation and roof. Plants in contact or proximity to home
can provide pathways for wood destroying insects, as well as abrade and
damage siding, screens and roofs.
• Prune or remove any plants that are in contact or proximity to home to
eliminate pathways of wood destroying insects.
• Tree limbs within 10 feet of roof should be trimmed away to provide air and
sunlight to roof, while minimizing debris & dampness.
• Trim trees that are in contact or proximity to home, as branches can abrade
roofing or siding.

Page 61 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Trim Trim

Trim
4. Gate Condition
Good Fair Poor N/A None
Materials: Wood
X Observations:
• The east side gate is in disrepair. Recommend repair/replacement before
occupancy.
5. Patio and Porch Deck
Good Fair Poor N/A None
Observations:
X • The back deck appears in satisfactory and functional condition with normal
wear for its age.
• Severe settlement observed under the east corner of the front deck.
Recommend invasive evaluation by a licensed contractor and review for
costs of repairs as needed before closing.

Page 62 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

General Condition General Condition

General Condition Settlement


6. Stairs & Handrail
Good Fair Poor N/A None

7. Grounds Electrical
Good Fair Poor N/A None
Observations:
X • No major system safety or function concerns noted at time of inspection.

8. GFCI
Good Fair Poor N/A None
Observations:
X • No GFCI protection observed in the plug at the back deck location.
Recommend review for costs of upgrade to current industry standards before
closing.

Page 63 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

9. Main Gas Valve Condition


Good Fair Poor N/A None
Materials: Main gas shut off located at outside meter - west side.
X Observations:
• Meter located at exterior. All gas appliances have cut-off valves in line at
each unit. No gas odors detected.

General Condition
10. Plumbing
Good Fair Poor N/A None
Materials: Copper piping noted.
X Observations:
• Appeared adequate and functional.
11. Water Pressure
Good Fair Poor N/A None

12. Pressure Regulator


Good Fair Poor N/A None

13. Exterior Faucet Condition


Good Fair Poor N/A None
Location: Front and rear of structure.
X Observations:
• Appeared adequate and functional.
14. Balcony
Good Fair Poor N/A None

15. Patio Enclosure


Good Fair Poor N/A None

Page 64 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

16. Patio and Porch Condition


Good Fair Poor N/A None
Materials: The patio/porch roof is the same as main structure.
X Observations:
• No major system safety or function concerns noted at time of inspection.
17. Fence Condition
Good Fair Poor N/A None
Materials: Wood
X Observations:
• **FENCING**
• Fence leaning in areas mostly on the east side of the home. Recommend
review for costs of repairs as needed before closing.
18. Sprinklers
Good Fair Poor N/A None

Page 65 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Foundation
1. Slab Foundation
Good Fair Poor N/A None

2. Foundation Perimeter
Good Fair Poor N/A None
Observations:
X • No deficiencies were observed at the visible portions of the structural
components of the home.
3. Foundation Walls
Good Fair Poor N/A None
Observations:
X • Normal settlement.
• Visible portions of foundation wall were dry at the time of the inspection.
See Limitations.
4. Cripple Walls
Good Fair Poor N/A None
Observations:
X • Concrete block/wood piers support floor above.

5. Ventilation
Good Fair Poor N/A None
Observations:
X • Screened openings noted.

6. Vent Screens
Good Fair Poor N/A None
Observations:
X • Vent screens noted as functional.

7. Access Panel
Good Fair Poor N/A None
Observations:
X • The foundation access panel installed and functional during the inspection.
• Limited inspection from the access area only due to standing water in the
crawlspace. Common condition for this area of town.

Location, kitchen closet Location

Page 66 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Water
8. Post and Girders
Good Fair Poor N/A None
Observations:
X • Beam Material: Wood
• Concrete block/wood piers support floor above.
• No deficiencies were observed at the visible portions of the structural
components of the home. See Limitations.

Typical
9. Sub Flooring
Good Fair Poor N/A None
Observations:
X • **DECKING**
• Plywood sheathing sub floor.
• **FRAMING**
• Dimensional lumber wood beams.
• Visible areas appear satisfactory at the time of inspection. See limitations.
• Mostly obscured by insulation.

Page 67 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

Typical
10. Anchor Bolts
Good Fair Poor N/A None
Observations:
X • The anchor bolts were not visible.

11. Foundation Electrical


Good Fair Poor N/A None

12. Foundation Plumbing


Good Fair Poor N/A None
Observations:
X • **SUPPLY**
• Not visible for identification.
• **DRAIN, WASTE, VENT**
• Acrylonitrile-Butadiene-Stryrene "ABS" waste and vent pipes noted.
• **OBSERVATIONS**
• Appears Functional at time of inspection.
• Most not accessible.

ABS

Page 68 of 69
Scott B. Moore Construction 2829 Barclay Rd., Medford, OR

13. Sump Pump


Good Fair Poor N/A None
Observations:
X • **SUMP PUMP**
• Could not access to verify if a sump pump is in place.
14. Ducting
Good Fair Poor N/A None
Observations:
X • Appeared functional, at time of inspection.

Typical

Page 69 of 69