Gas Well Data Drawdown Test Data Pi (psia) t (horas) Pwf (psia) ψ (pwf) -psia^2/cp ɸ Swi Vw (ft^3) h (ft) T (F) rw (ft) µi (cp) qg (Mscf/D) ɣ Cti (psi^-1) Área (acres)

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

GAS WELL DATA DRAWDOWN TEST DATA

Pi (psia) 3000 t (horas) Pwf (psia) ψ(pwf)-psia^2/cp


ɸ 0.19 0.000 3000 6.338E+08
Swi 0.211 0.024 2964 6.210E+08
Vw (ft^3) 286 0.096 2920 6.055E+08
h (ft) 10 0.244 2890 5.947E+08
T (F) 200 0.686 2866 5.864E+08
rw (ft) 0.365 2.015 2848 5.801E+08
µi (cp) 0.01911 6 2833 5.747E+08
qg (Mscf/D) 1000 17.96 2817 5.693E+08
ɣ 0.7 53.82 2802 5.640E+08
Cti (psi^-1) 2.35E-04 161 2786 5.585E+08
Área (acres) 640 281 2777 5.553E+08
401 2771 5.532E+08
521 2766 5.517E+08
641 2763 5.505E+08
761 2760 5.494E+08
881 2757 5.485E+08
GAS WELL DATA DRAWDOWN TEST DATA
Pi (psia) 3000 Time (Hours) Pwf (psia) ψ(pwf)-psia^2/cp
ɸ 0.19 0.000 3000 6.338E+08
Swi 0.211 0.024 2964 6.210E+08
Vw (ft^3) 2.86E+02 0.096 2920 6.055E+08
h (ft) 10 0.244 2890 5.947E+08
T (F) 200 0.686 2866 5.864E+08
rw (ft) 0.365 2.015 2848 5.801E+08
µi (cp) 0.01911 6 2833 5.747E+08
qg (Mscf/D) 1000 17.96 2817 5.693E+08
ɣ 0.7 53.82 2802 5.640E+08
Cti (psi^-1)
2.35E-04 161 2786 5.585E+08
Área (acres) 640 281 2777 5.553E+08
401 2771 5.532E+08
521 2766 5.517E+08
641 2763 5.505E+08
761 2760 5.494E+08
881 2757 5.485E+08

ΔP vs t
1.000E+09
1.000E+08
1.000E+07
1.000E+06
Axis Title

1.000E+05
1.000E+04
1.000E+03
1.000E+02
1.000E+01
0.01 0.1 1 10
Axis Title
Del gráfico vemos que tiene una pendiente recta (45 grados) y de e
para este caso escogemos el siguiente punto:

t (hrs) 0.0218
Pi-Pwf (psia) 47.0

C (RB/psi) 0.0212
Grafico Semilog de Prueba Drawdown
7.000E+08

6.800E+08

6.600E+08

6.400E+08

Flowing BHP (psia)


6.200E+08

6.000E+08

5.800E+08

5.600E+08

5.400E+08

5.200E+08

5.000E+08
0.01 0.1 1

Time (Hours)

ΔP vs t

1 10 100 1000
Axis Title
te recta (45 grados) y de esa pendiente escogemos un punto cualquiera
og de Prueba Drawdown

1 10 100 1000

Time (Hours)

m (psi/ciclo) 880
P1H (hrs) 2020

k (md) 0.21
s 5.37
GAS WELL DATA DRAWDOWN TEST DATA
Pi (psia) 3000 Time (Hours) Pwf (psia) ψ(pwf)-psia^2/cp Δψ(p)-psia^2/cp
ɸ 0.19 0.000 3000 6.037E+08
Swi 0.211 0.024 2964 5.915E+08 1.220E+07
Vw (ft^3) 2.86E+02 0.096 2920 5.766E+08 2.710E+07
h (ft) 10 0.244 2890 5.665E+08 3.720E+07
T (F) 200 0.686 2866 5.585E+08 4.520E+07
rw (ft) 0.365 2.015 2848 5.525E+08 5.120E+07
µi (cp) 0.01911 6.000 2833 5.475E+08 5.620E+07
qg (Mscf/D) 1000 17.960 2817 5.422E+08 6.150E+07
ɣ 0.7 53.820 2802 5.372E+08 6.650E+07
Cti (psi^-1) 2.35E-04 161 2786 5.319E+08 7.180E+07
Área (acres) 640 281 2777 5.290E+08 7.470E+07
401 2771 5.270E+08 7.670E+07
521 2766 5.253E+08 7.840E+07
641 2763 5.244E+08 7.930E+07
761 2760 5.234E+08 8.030E+07
881 2757 5.224E+08 8.130E+07
ψ(pwf)-psia^2/cp

Grafico Semilog de Prueba Drawdown


7.000E+08
6.800E+08
6.600E+08
6.400E+08
6.200E+08
6.000E+08
5.800E+08
5.600E+08
5.400E+08
5.200E+08
5.000E+08
0.01 0.1 1 10 100 1000

Time (Hours)

Del ploteo de ψ(pwf) vs Log Δt, la forma de la curva nos sugiere que la distorsión por almacenamiento finaliza
a t=1 hr y los efectos de frontera empiezan cerca de t=200 hrs.

Se observa:
ψ(p1hr) 5.558E+08

*El valor absoluto de la pendiente del MTR es:

X Y
2.015 5.525E+08
161 5.319E+08

m (psia^2/cp-ciclo) 1.083E+07

*Procedemos hallar la permeabilidad:

k (md) 9.98
*Procedemos hallar el daño aparente:

s -0.33

El pozo aparentemente esta ligeramente estimulado.

Procedemos hallar los radios de investigación al comienzo y fin del MTR:

*Radio de investigación al comienzo del MTR:

t (horas) 1

ri (ft) 111

*Radio de investigación al final del MTR:

t (horas) 200

ri (ft) 1571

You might also like