Sheet1

Slab Design Frame Structure only

Inputs Caln.
Fc` = 3000 psi Fc = 1350 psi 1 MPa = 145.038 psi
= 20.68 Mpa Fs = 36000 psi 1 KPa = 0.145038 psi
Fy = 60000 psi n = 20
= 413.68 MPa k = 0.429 Colum Size (in Inch)= 10
Kn = 5.68 MPa j = 0.857
(From side table 3.1) R = 248 psi b 10
Vc = 60 psi
Thickness determination a

Long Span, l1 = 18.00 ft = 5.61 m ln = 5360.97 mm


Short Span, l2 = 15.00 ft = 4.68 m ln-s = 4425.81 mm

Thickness, h = ln (( 800/1000 ) + fy / (1.5*1000 )) / (36000/1000) = 160 mm


Fix Thickness, h = 6.5 inch = 162.5 mm

5.6 5.6 5.6 1.294 m

4.68 2.338 m

2.338 m
b= width of colm strip =
2.81 m
4.68 2.338 m

2.338 m

4.68 2.338 m

1.294 m

1.53 2.81 2.81 2.81 2.81 2.81 1.53 m

Page 1
Sheet1

Load Inputs

Dead Load ( @ 150 lb/cft ) = 81.25 ( psf ) 3.89 Kpa


F.F. = 25 ( psf ) 1.20 Kpa
Partition (considering all partition wall on the floor) = 80 ( psf ) 3.83 Kpa ( TO BE CALCULATED SEPERATELY )
Live Load = 40 ( psf ) 1.92 Kpa

Total DL & LL= W = 226.25 ( psf ) 10.84 Kpa


Total DL & LL=(1.4DL+1.7LL), is not being used
Depth Check for Shear:-

Clear Cover = 0.75 inch 18.75 mm


To be used bar No = 12 mm
Avg. steel depth, d = (h - clear cover - bar no. / 2) = 137.75 mm
Width of each side, b = 0.388 mm
Fully factored shear force,Vu=W(pannel size-(minm colm face side + d)) = 282.66 KN
Nominal shear strength, Vn = Vu / 0.85 = 332.54 KN
Allowable vc = 1/3*SQRT(Fc') = 1516.00 KN
du = Vn / ( vc*b ) = = 141.43 mm < h =162.5
O.K.

Moment Calculation:-

dl = h - clear cover - bar dia/2 = 137.75 mm


ds = h - clear cover - 1.5*bar dia = 125.75 mm
MO (for long span) = 0.125*W*l2*ln^2 = 0.182 MN-m
MO (for short span) = 0.125*W*l1*ln-s^2 = 0.149 MN-m

Depth Check for Moment:-

The highest moment is the long span -ve moment.

Mu ( long span ) = 0.75 ( 0.65 Mo ) = 0.089 MN-m


Mn = Mu / 0.9 = 0.099 MN-m
Required Kn = Mn / bd2 = 2.22 MPa < 5.68 MPa

Page 2
Sheet1

O.K.

Page 3
Sheet1

Steel Calculation:-

Long Span = 5.61 m c/c Short Span = 4.68 m c/c


Colm Strip 2337.91 (mm) Midl.Strip 2337.91 (mm) Colm Strip 2805.49 (mm) Midl.Strip 2805.49
(-Ve) (+Ve) (-Ve) (+Ve) (-Ve) (+Ve) (-Ve) (+Ve)
Slab Thickness, "h" in mm 162.5 162.5
Effective depth, "d" in mm 137.75 125.75
Mo in KN-m 182.017 148.86
Mu = Mo / 0.9 202.2412 165.41
Resisting Moment .49Mu .21Mu .16Mu .14Mu .49Mu .21Mu .16Mu .14Mu
Mn in KN-m 99.0982 42.4707 32.3586 28.3138 81.0486 34.7351 26.4648 23.1567
fy in MPa = 413.68 413.68
z = .95d 130.8625 119.4625
zfy = 54135.81 49419.81
As =Mn /zfy in mm2 = 1830.55 784.52 597.73 523.01 1640.00 702.86 535.51 468.57
Min. As =.0018*b*h = 683.8373 683.8373 683.8373 683.8373 820.6047 820.6047 820.6047 820.6047
# of bar = 12 12 12 12 12 12 12 12
Spacing in mm = 144 337 386 386 193 386 386 386
Maxm spacing=2*h= 325 325 325 325 325 325 325 325
Spacing should be= 144 325 325 325 193 325 325 325

Column Design
3 = 14
Inputs Caln. Colm zone
Fc` = 2500 psi Fc = 1125 psi
Fy = 60000 psi Fs = 36000 psi 1= 16 2= 15
n = 24 C-3
k = 0.429
j = 0.857
R = 207 psi
Vc = 55 psi 4 = 12

Page 4
Sheet1

Column No. = C-3 Load Inputs Length= 9.5 ft


Supported Span No. 1 2 3 4 Size, a (in) 12 Ag = 144 sq.inch
Span Length ( ft ) = 16 15 14 12 b (in) 12 Dead Load 1425 pound
Col.zone ( sft ) 202 Load from slab = 45589 pound
Load per Level,w = 47014 pound/floor
multiply by No. of Levels= 6
Total Load , P = 282086 pounds
DESIGN CALCULATION

P = 282086 lbs Load carried by Steel ( Lb) 192086


Ag = 144 sq.inch Use #5 bar Steel Area 0.44 sq.inch
Load carried by conc.(Lb) 90000 No. of bars reqd.= 12.1 Nos.
Provide 12.1 Nos. of bars
Provide # 3 bar as ties 10 in c/c. Stirrup Calculation
48 tie dia= 18 inch
16 bar dia= 10 inch
Col.width= 12 inch

Footing Design
Inputs Caln.
Fc` = 2500 psi Fc = 1125 psi
Fy = 60000 psi Fs = 36000 psi
Bearing Capacity = 3500 psf n = 24
k = 0.429
Total Load from Col., P = 282086 Pounds j = 0.857
Add 10% as Footing Self Wt.= 28209 Pounds R = 207 psi
Total Load on Footing, F = 310295 Pounds Vc = 55 psi
Vpunching= 100 psi
Design Calculation :- Corresponding Col. Size
Reqd. Footing Area= 88.7 sft Provide Footing Size,L= 7.0 ft 12.0 in
Reqd.Footing Size= 9.4 ft Square B = 7.0 ft 12.0 in
For rectangle B = 14.0 ft Provided Footing Area 49.0 sft
L = 6.3 ft So,Contact Pressure 6333 psf
Check Punching Shear Moment in Short Dir. = 28496 Lb-ft / ft
Net Punching Load = 110580 Pounds Moment in Long Dir. = 28496 Lb-ft / ft

Page 5
Sheet1
Punching Perimeter= 100.0 in D required due to moment 11.7 in
Punching Shear, V = 85 psi Provide Effective Depth, D 13.0 in
Allowable Vpunching= 100 psi So, Thickness of Footing = 16.0 in
O.K.
Reinforcement Calculation
FootingNo. 1
M -Short M -Long Eff.Depth Eff.Depth As - Short As - Long
(#-ft) (#-ft) Short (in) Long(in) Area(sq-in) Area(sq-in)
28496 28496 12.0 13.0 0.92 0.85

Spacing of Steel ( nos. @ in c/c )


Steel Size Steel Area
3/8 inch dia 0.11 sq-in 1 2
1/2 inch dia 0.2 sq-in 3 3
5/8 inch dia 0.31 sq-in 4 4
6/8 inch dia 0.44 sq-in 6 6
7/8 inch dia 0.6 sq-in 8 8

DESIGN OF STAIR

Inputs Caln.
Fc` = 2500 psi Fc = 1125 psi
Fy = 40000 psi Fs = 24000 psi
n = 16
k = 0.429
j = 0.857
R = 207 psi
Vc = 55 psi

Inputs
Span L = 10 ft
Height of Floor = 10 ft b
Riser = 6 inch
Tread = 11 inch t
Slab thickness , t = 5 inch
Finishing = 15 lb/sq-ft
Live load = 60 lb/sq-ft L

Page 6
Sheet1
Calculation

Height of Flight = 5 ft LOAD PER FEET OF STEP :-


No of riser in each flight = 10 Nos Self wt of step = 34.375 lb/ft
No of tread in each flight = 9 Nos Self wt of waist slab = 62.5 lb/ft
Space reqd for treads = 8.25 ft Floor finish = 13.75 lb/ft
Space left for Landing = 1.75 ft for one lan. Live Load = 55.00 lb/ft
0.875 ft for two lan. Total Load = 165.63 lb/ft
b = 12.53 inch

Moment (#-ft) D req (in inch) D actual (in inch) Steel required(sq-in) Distribution Steel
2070 3.17 4.25 0.284 0.16
O.K.
Spacing of Steel ( nos. @ in c/c )
Steel Size Steel Area
3/8 inch dia 0.11 sq-in 5 8
1/2 inch dia 0.2 sq-in 8 15
5/8 inch dia 0.31 sq-in 13 24
6/8 inch dia 0.44 sq-in 19 34
7/8 inch dia 0.6 sq-in 25 46

Page 7
Sheet1

TABLE - 3.1:-Values of Limiting Constant, Kn

Steel:- fy = 300 Mpa fy = 400 Mpa


Cocrete Gr f 'c, MPa km, MPa kn, MPa km, MPa kn, MPa
C20 20 5.11 5.68 4.73 5.25
C25 25 6.4 7.11 5.92 6.58
C30 30 7.68 8.53 7.1 7.89
C35 35 8.65 9.61 7.98 8.87
C40 40 9.51 10.56 8.77 9.74

Page 8
Sheet1

(mm)

Page 9