E290 MT Rev.0 PDF
E290 MT Rev.0 PDF
MT Procedure
Rev. Rev.
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
PAGE No. PAGE No.
1 X 36
2 X 37
3 X 38
4 X 39
5 X 40
6 X 41
7 X 42
8 X 43
9 X 44
10 45
11 46
12 47
13 48
14 49
15 50
16 51
17 52
18 53
19 54
20 55
21 56
22 57
23 58
24 59
25 60
26 61
27 62
28 63
29 64
30 65
31 66
32 67
33 68
34 69
35 70
DOCUMENT No. DOCUMENT TITLE PO. NO.:
Contents
1. SCOPE
2. REFERENCE
3. SURFACE PREPARATION
4. MAGNETIC PARTICLES
5. MAGNETIZATION METHOD
6. DEMAGNETIZATION
8. METHOD OF EXAMINATION
9. INTERPRETATION
15. CALIBRATION
DOCUMENT No. DOCUMENT TITLE PO. NO.:
1) SCOPE
This article contains methods and requirements for Magnetic Particle Examination of Heat Exchangers
for SARKHUN NATURAL GAS PROJECT.
2) REFERENCE
- ASME Sec. V, Article 7, (Edition 2007)
- ASME Sec. VIII, Div. 1, (Edition 2007))
- ASNT-TC-1A (2006 Edition)
3) SURFACE PREPARATION
3.1. Satisfactory results are usually obtained when the surfaces are as welded conditions .however,
surface preparation by grinding or machining may be necessary where surface irregularities could
make indication due to discontinuities.
3.2. Prior to magnetic particle examination, the surface to be examined and all adjacent area within at
least 25.4 mm shall be dry and free of all dirt, grease, welding flux and spatter, oil or other extraneous
matter that could interfere with the examination.
3.3. Cleaning may be accomplished using detergents, organic solvents, paint remover, vapor
degreasing, grit blasting, or ultrasonic cleaning methods.
3.4. If coatings are left on the part in the area being examined, it must be demonstrated that
indication can be detected through the existing maximum coating thickness applied.
4) MAGNETIC PARTICLES
4.1. The magnetic particles used for finding discontinuities will be wet method. Powders for wet test
are non- fluorescent. The powders used will be as liquid suspension, they shall have a high permeabil-
ity and a low capacity of keeping magnetization. Particles shall be visible under normal light. The
following powders and / or similar will be used:
- Natural light black (Magnaflux or equivalent)
- Red (Magnaflux or equivalent)
4.2. Two types of Liquid Carriers may be used:
4.2.1. Oil - bath
The oil used in preparing the bath shall be light oil or refined oil having a low sulphur and chloride
limits content: Further it shall completely with the requirement of the ASME regulations.
When using oil as carrier of fluorescent particles, it shall be controlled by black light so that is gets
DOCUMENT No. DOCUMENT TITLE PO. NO.:
5) MAGNETIZATION METHOD
5.1. The Electromagnetic Yoke Technique shall be used. This method shall be performed only to
surface and sub-surface discontinuities.
5.2. The AC magnetizing technique will be used provided that it has a 4.5 kg lifting that weighed with
a scale from a reputable manufacturer. This test shall be performed before use; recording of this test is
not required.
5.3. The DC technique will be used provided that it has 18 kg lifting capacity at the maximum
Pole spacing. This test shall be performed before use; recording of this test is not required.
5.4. Two examinations at least shall be carried out in every area where the prods are placed so that the
flux lines result approximately perpendicular.
5.5. Two examination at least shall be carried out with a sufficient overlapping (MIN. 15%
overlapped) so as to ensure the 100% covering of the surface to be tested.
6) DEMAGNETIZATION
When residual magnetism in the part could interfere with subsequent or usage, the part shall be
demagnetized any time after completion of the examination.
DOCUMENT No. DOCUMENT TITLE PO. NO.:
8) METHOD OF EXAMINATION
Examination shall be done by continuous method: that is the magnetizing current remains on while the
examination medium in being applied and while excess of the examination medium is being removed.
9) INTERPRETATION
For Non–fluorescent particles examination is performed using visible light. A minimum light intensity
of 50 FC (500 Lx) is required to ensure adequate sensitivity during the examination and evaluation of
indication.
of circular or elliptical shape with a length equal to or less than three times the width. Any
questionable or doubtful indication shall be re-examined to determine whether or not they are relevant.
Light Meters:
Light meters shall be calibrated at least once a year or whenever the meter has been repaired. If meters
have not been in use for one year or more, calibration shall be done before being used.