AIR HANDLING CABINETS

CIATRONIC SYSTEM
SOLUTIONS FOR DATA CENTERS

NA 10.114 D
CIATRONIC System
System
PRODUCTION AIR HANDLING

OPTIMISATION
FR
EE C
HILLI

AQUACIATPOWER
NG

E
EF
FICIENC
Y
& EXPERTISE
> OPTIMISING YOUR PUE:
R
MO

OWER
 Our multiple compressor EN P FR
GRE
the keys to an energy-efficient system EE C G
OOLIN

L E S S CO
2

technology, ideally suited to


• Water: the best vector for • Higher air temperature ranges MAGISTER
partial load situations, plays
optimising your system. enable higher water temperature
a significant role in achieving
• Room design: optimum server ranges, thus increasing the number  Excellent compromise between power
excellent PUE (Power Usage layout and hot aisle/cold aisle of hours when free cooling becomes supplied and footprint.
Effectiveness). partitioning keep air temperatures possible.  Larger transfer area for increased
under control. free cooling.
 No need for a dedicated mechanical
room.

60%
ADDITIONAL
FR
FREE COOLING
INCREASED
5°C
EE C NG
HILLI
CLIMACIAT
OPERA WATER TEMPERATURE AIRTECH
INCREASED
5
 Excellent balance between footprint and
discharged power.
AIR TEMPERATURE °C  Direct free cooling solution with fresh air/
return air mixing box.
 EC motor for reduced energy consumption (PUE)
 Overpressurisation of rooms.

ITEX
CRISTOPIA
 A wide range of plate heat  One of the free chilling solution
STORAGE exchangers for decoupling between components.
FR
EE C
OOLIN
G

energy production and the


 Cristopia nodules secure your production and offer secondary network (air handling).
12 hours of cooling autonomy.
CIATRONIC System
System
The high performance range

Expair
Magister Climrack Capacity: 5 to 50 kW
Capacity: 10 to 130 kW
Capacity: from 5 to 18 kW
• Temperature and humidity monitoring
• Temperature and humidity monitoring • Chilled water or direct expansion air cooling
• Chilled water or direct expansion air cooling • Water-cooled rack
• Many options
• A host of custom features, a wide choice of options and air • Cooling at source
• Competitiveness
flow systems • Compact
• Availability
• High energy efficiency • 47U or 52U rack
• Low sound level • Condensation-free solution
• High-efficiency filtration
• Maximum security for your facilities
Magister
Exacting performance

ENERGY SAVINGS ENHANCED SECURITY FOR YOUR SYSTEMS

• Rotation/Backup/Auxiliary functions between cabinets (up to


• Plug fan for enhanced air handling efficiency combined > Chilled water (CW) models 10 units)
with an EC motor for optimum energy efficiency • MODBUS/JBUS/LON protocol communication for real-time
• Self-regulating control: the automatic controller varies > Direct expansion (DXA) models information
the air handling fan speed depending on the room's load • 25 mm compressed double-skin insulation: M0 fire resistance
or the pressure drop in the raised floor • Options: - LON Gateway
• Enthalpic free cooling module (option): the data center is - Raised floor pressure control
cooled by fresh air taken from outside, depending on the - Change-over sensor
temperature and humidity conditions.
PLC

ADAPTATION

• Chilled water or direct expansion system cabinet


• Temperature and humidity monitoring
• Sound level reduced thanks to:
- Double-skin insulation
- Air flow rate adapted to cooling demand
- Optimised airflow: reduced system effect,
air velocity below 2.5 m/s
PLUG FAN (EC motor) • Compact and unobtrusive design for perfect integration into
premises
• Modbus module* as standard for communica- • Continuous air filtration
tion between the fan and the controller to gather • Setpoint stability guaranteed by automated control system
data on fan faults, power and input currents. technology (PI or PID) and pressure control valve (gradual)
* Only for Magister CW • Associated CD condensation units
• SCROLL R410A compressor

EASY HANDLING AND MAINTENANCE SYSTEM INTEGRATION


Magister : La solution DATA CENTERS
• Sturdy, resistant housing, with front access
• Fan/motor direct coupling • Combining chilled water production, free cooling and
• Filters mounted on supports for easy handling air diffusion, Magister integrates perfectly into CIAT's
• Networked control devices enables information to be comprehensive solution for DATA CENTERS.
Condenciat CD
fed back to the monitoring system • The variable speed control of the EC motors, associated with
the flexibility offered by water - a natural coolant, provides a solution to:
- Variations in data center loads over time
- The demands of Tier IV classification
- Developments in data centers and their modular needs.
Expair
Expair
Performance and efficiency

EASY INTEGRATION ON SITE > Chilled water (CW) models


• Direct-drive centrifugal fan controlled by frequency > Direct expansion air (DXA)
variation to adjust the flow rate and pressure to the air
duct network
• Optimised, compact footprint
• Networked control of cabinets and feedback to a BMS
possible (MODBUS/JBUS/LON) COMPETITIVENESS AND PERFORMANCE

• Temperature and humidity monitoring


• Double-skin panels for improved sound
dampening (M0 fire resistance)
• Wide range of options
AVAILABLE QUICKLY • Chilled water or direct expansion, air-cooled
condensation
Main components in stock: • Free cooling module (option) takes in fresh
• panels air from outside.
• coils
• condensation units
• humidifiers
• filters
• electric heaters

EASY INSTALLATION AND MAINTENANCE


SIMPLICITY AND EFFICIENCY
• Flexible couplings kit for hydraulic connections Condenciat CL
• Front panel access • Associated CONDENCIAT CL condensation units
• Pre-charged outdoor units (direct expansion model) • Sleek design and finish
• Accessible connections • High energy efficiency
• Handling: lightweight, aluminium chassis • SCROLL compressor and R410A refrigerant
(compressors are in the outdoor unit) • Speed control board to match the fan speed to the
• Easy removal of filters condenser's exchange requirements
• Optional condensate drain pump. • Installation: the outdoor unit may be placed up to 50 metres
away from the indoor unit
Choice of technologies Assemblies
Assemblies
Fitting
Design

Performance
Performance
Performance
Options

APPLICATION EXPAIR MAGISTER > ASSEMBLIES


CW 5 to 55 10 to 130
Capacity range (kW)
DXA 5 to 47 50 to 86
PERFORMANCE Number of models available
* chilled water CW 7 5  Expair  Expair
* direct expansion DXA 11 4  Magister  Magister
FILTRATION Filtration efficiency G4 / F7 / G4 + F7 G4 / F7
Coil frame Galvanised steel Galvanised or stainless steel
COOLING COIL
Condensate pan Aluminium Aluminium/Stainless steel
Direct drive centrifugal fan motor Plug Fan fan motor assembly (EC
FAN Fan with variable flow rate/pressure assembly with variable frequency motor) with 0-10 V signal for speed
drive variation
Humidifier Electrode
HUMIDITY
MONITORING Humidification control Progressive
(option) Dehumidification monitoring Option
 Expair
Hot water coil Option  Expair  Magister CW
HEATING COIL Electric heater Shielded stainless steel element
(option)
Electric heater control 2-stage or TRIAC

Available configurations 1 / 3 / 4 or 5 1 / 3 or 5*
Water coil controlled by
CONFIGURATION
Chilled water model (CW) 2-way or 3-way progressive valve > CABINET PERFORMANCE
Cabinet associated with 1 or 2 CIAT Cabinet associated with 2 CIAT CD
Direct expansion air (DXA) CL condensation units condensation units
Chilled water range EXPAIR CW
(compressor outdoors) (compressor outdoors) Chilled water model (CW) CW5 CW8 CW12 CW16 CW27 CW39 CW59
Air flow (m3/h) 1300 2000 2500 3000 4000 5000 6000 7000 8000 10000 12000
Controls CIAT µair connect 2
Cooling capacity (kW)) 5 8 10,5 14,7 18 23 27 34 38 48 55
Protocol MODBUS / JBUS / LON
Rotation/backup/auxiliary YES Chilled water range MAGISTER CW
Display text Chilled water model (CW) CW40 CW53 CW78 CW100 CW115
Filter fouling indicator standard Nominal* Maximum** Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum
Air flow (m3/h)
Air flow monitoring standard 10000 13300 13300 13300 18800 20500 24500 26600 27000 27500
CONTROL SYSTEM Water leak sensor standard Sensible cooling capacity (kW) 40 45 55 53 78 78 100 100 127 130
*7/12°C 24°C/45% **10/15 26°C/40%
Low limit control on discharge option
Direct expansion range EXPAIR DXA
Management of pressure in raised floor** option
DXA model DXA 5 DXA 8 DXA 10 DXA 12 DXA 15 DXA 19 DXA 24 DXA 31 DXA 36 DXA 38 DXA 48
Changeover sensor option
Air flow (m3/h) 1300 2000 2500 3000 4000 5000 6000 7000 8000 10000 12000
Room temperature sensor option 30,1 35 38 47
Total power (kW) 5 8 10,6 11 15 19 23,2
Room temperature and humidity sensor option Number of circuits 1 1 1 1 1 1 1 2 2 2 2

Frame Aluminium frame Aluminium frame Direct expansion range MAGISTER DXA
CONSTRUCTION Double-skin construction with Double-skin construction with DXA model DXA 59 DXA 65 DXA 70 DXA 85
Panels compressed glass wool compressed glass wool
(M0 fire rating) (M0 fire rating) Air flow(m3/h) 15000 15700 18500 21000
Compressor fluid R410A R410A Total power (kW) 60 67 72 86
REFRIGERANT CIRCUIT (DXA) Number of circuits 2 2 2 2
Compressor technology SCROLL SCROLL
Adjustable support frame YES YES > CLIMRACK PERFORMANCE
Supply plenum YES YES
OPTIONS CLIMRACK
Motor-driven air intake damper YES YES Return air Water temperature Humidity T°
temperature / humidity range (°C) Power (kW) Water flow rate (m3/h) for supply air Pressure drop (mWC)
Free cooling plenum thermo enthalpic
33°C/10 g/kg dry air 13/18 14 2,4 22.5°C/10 g/kg dry air 2.13
33°C/10 g/kg dry air 14/19 13 2.24 23.2°C/10 g/kg dry air 1.87
* CW115: Configuration 1 only 37°C/10 g/kg dry air 13/18 18 3,09 23.5°C/10 g/kg dry air 3.39
** Only for Magister CW 37°C/10 g/kg dry air 14/19 17 2,93 24.2°C/10 g/kg dry air 3.06
Present in over 70 countries

Over 10 million units in


2200 employees 9 production centers
operation around the world

CIAT, EUROPE'S
OUR REFERENCES

LEADING NAME TELECOMMUNICATIONS


MTN South Africa/Cameroon
IN AIR SFR France
France Telecom France
HANDLING Belgacom Belgium
Postes et Télécommunications Luxembourg
Mobilcom Germany
CIAT possesses unrivalled expertise, T-System Switzerland
building on over 75 years of experience, Algérie Télécom Algeria
of which have been in providing Free France
solutions for data centers.
With 9 production plants around the DATA CENTERS
world and offices in over 70 countries, NATO Belgium
CIAT is the key partner for your projects. CERN Switzerland
Drawing on tour skills, experience and Météo France France
our R & I potential, we offer a range of Michelin France
solutions that meet the specific needs of Société Générale Romania
DATA CENTERS. Total France
EADS France
Cairo Metro Egypt

This document is not legally binding. As part of its policy for continual product improvement, CIAT reserves the right to make any technical modification it considers necessary without prior notice.