ACUSON X300

US

System Introduction
System
Definitions, Acronyms and Conventions

© Siemens AG 2006
The reproduction, transmission or use
of this document or its contents is not
permitted without express written
Siemens Medical Solutions
ejt
Ultrasound
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.

Print No.: US11-101.810.01.01.02 English


Replaces: n.a. Doc. Gen. Date: 09.06
n.a.

Part No.:
sd
2 Revision / Disclaimer
1Revision / Disclaimer

Copyright
Copyright © 2006 by Siemens Corporation. All rights reserved. No part of this publication
may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into
any language or computer language, in any form or by any means, electronic, mechanical,
magnetic, optical, chemical, manual, or otherwise, without the prior written permission of
Siemens Corporation. Siemens Corporation reserves the right to change its products and
services at any time. In addition, this manual is subject to change without notice. Siemens
Corporation welcomes customer input on corrections and suggestions for improvements
to this manual.Although Siemens Corporation has attempted to ensure accuracy through-
out this manual, Siemens Corporation assumes no liability for any errors or omissions, nor
for any damages resulting from the application or use of this information.
Trademarks
ACUSON, Sequoia, Cypress, AEGIS, Aspen, 128XP, XP, AcuNav, CV70, SONOLINE,
SONOVISTA, Adara, Antares, G20, G40, G50, G60S, X300, X500, Omnia, Premier and
KinetDx are trademarks of Siemens Corporation registered in the U.S. Patent and Trade-
mark Office. CWS3000, DS3000, WS3000, and WebPro are trademarks of Siemens Cor-
poration.
Windows XP, 2000 and NT are registered trademarks of Microsoft Corporation. Internet
Explorer is a trademark of Microsoft Corporation. Netscape and Netscape Navigator are
registered trademarks of Netscape Communications Corporation. Java and the JavaScript
name are registered trademarks of Sun Microsystems, Inc. Adobe Acrobat is a registered
trademark of Adobe Systems, Inc.
Other products and brand names are trademarks of their respective owners.
Disclaimer
The service of equipment described herein is to be performed by qualified personnel who
are employed by Siemens or one of its affiliates or who are otherwise authorized by Sie-
mens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service pro-
cedures.
License Agreement
All computer programs copyright 1990-2006 by Siemens Corporation or its suppliers. Pro-
grams are licensed under the following agreement:
Siemens or its suppliers retain(s) ownership of and title to any computer program supplied
with the equipment and to the trade secrets embodied in such computer programs. Sub-
ject to the Buyer’s acceptance and fulfillment of the obligations in this paragraph, Siemens
grants the Buyer a personal, non-transferable, perpetual, non-exclusive license to use any
computer program supplied with the Equipment that is necessary to operate the Equip-
ment solely on the medium in which such program is delivered for the purpose of operat-
ing the equipment in accordance with the instructions set forth in the operator’s manuals
supplied with the Equipment and for no other purpose whatsoever. Buyer may not
reverse-assemble, reverse-compile or otherwise reverse-engineer such computer pro-
grams nor may Buyer make a copy of such program or apply any techniques to derive the

ACUSON X300 US11-101.810.01.01.02 Page 2 of 12 Siemens


09.06 sd Medical Solutions USA, Inc.
Revision / Disclaimer 3

trade secrets embodied therein. In the event of a failure by Buyer to comply with the terms
of this license, the license granted by this paragraph shall terminate. Further, because
unauthorized use of such computer programs will leave Siemens without an adequate
remedy at law, Buyer agrees that injunctive or other equitable relief will be appropriate to
restrain such use, threatened or actual. Buyer further agrees that (i) any of Siemens"s
suppliers of software is a direct and intended beneficiary of this end-user sublicense and
may enforce it directly against Buyer with respect to software supplied by such supplier,
and (ii) No supplier of Siemens shall be liable to buyer for any general, special, direct, indi-
rect, consequential, incidental or other damages arising out of the sublicense of the com-
puter programs supplied with the equipment.

Siemens US11-101.810.01.01.02 Page 3 of 12 ACUSON X300


Medical Solutions USA, Inc. 09.06 sd
4 Table of Contents
1- 0Table of Contents

1 _______ Definitions, Acronyms and Conventions_____________________________ 5

Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Definition, Acronyms and Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2 _______ Changes to Previous Version _____________________________________ 11

Changes to Previous Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

ACUSON X300 US11-101.810.01.01.02 Page 4 of 12 Siemens


09.06 sd Medical Solutions USA, Inc.
Definitions, Acronyms and Conventions 5
2-
Safety Information
1Definitions, Acronyms and Conventions

Definition, Acronyms and Conventions 0

Alerts
Caution alerts notify the user and service personnel of potential hazards to the equipment
and are presented in the following format:

CAUTION The system contains components that are sensitive to damage by


electrostatic discharge (ESD).
¹ Observe ESD protective procedures and use ESD protec-
tive equipment-including an ESD wrist strap-when pro-
tective covers are removed from the system.

Warning alerts notify the user and service personnel of potential hazards to the user, the
patient, or to service personnel and are presented in the following format:

WARNING The system contains hazardous voltages that can range from 90
VAC to 264 VAC and cause serious injury or death.
¹ Only authorized service personnel are permitted to
remove protective covers and access the energized com-
ponents of this system.

Notes
Notes contain helpful suggestions or references to material not covered in the document:

NOTE The ultrasound system is not designed to be used as an archive


device.

Siemens US11-101.810.01.01.02 Page 5 of 12 ACUSON X300


Medical Solutions USA, Inc. 09.06 sd
6 Definitions, Acronyms and Conventions

Definitions
Tab. 1 Acronym Definitions

Term Acro- Definition


nym
Field Replacement Unit FRU A part on the ultrasound system that may be
replaced in the field.
Replace - To exchanged a faulty FRU with an operative
FRU.
To install the same operative FRU that was
previously removed from the system, back
from which it came.

ACUSON X300 US11-101.810.01.01.02 Page 6 of 12 Siemens


09.06 sd Medical Solutions USA, Inc.
Definitions, Acronyms and Conventions 7

Acronyms 0

ACP AC Power Module


ADC Analog to Digital Converter
AOP Acoustic Output Power
ASIC Application Specific Integrated Circuit
AV Audio and Video
AVIF Audio Video Interface
BE Backend
BIST Built in Self Test
BIT Built in Test
CD/DVD-R/RW Compact Disk / Digital Versatile Disc - Recordable/Rewriteable
CPLD Complex Programming Logic Device
CP Control Panel
DAC Digital to Analog Converter
DGC Depth Gain Control
DHCP Dynamic Host Configuration Protocol
DICOM Digital Imaging and Communications in Medicine
DIMAQ Digital Image Acquisition
DIMM Dual Inline Memory Module
DLL Dynamic Link Library
ECG Electrocardiogram
ECPR Echo Processor
EM Electronics Module
EMIFIL EMI (Electro-Magnetic Intererence) Filter
EMUX Echo Multiplexer
EP Echo Processor
EPLD Embeded programable logic device
ESD Electrostatic Discharge
ETX Embedded Technology Extended Module

Siemens US11-101.810.01.01.02 Page 7 of 12 ACUSON X300


Medical Solutions USA, Inc. 09.06 sd
8 Definitions, Acronyms and Conventions

FPD Flat Panel Display


FDA Food and Drug Administration
FRU Field Replaceable Unit
FE Frontend
FiFo Fast in Fast out memory
FOV Field of View
FPGA Field Programmable Gate Array IC
HDD Hard Disk Drive
HPRF High Pulse Rate Frequency
HV-MUX High Voltage Multiplexer
IDE Intergrated Drive Electornics
IQ In Phase/ Quadrature phase
IO or I/O Input-Output Board
IOS Input Output Sub Board
IQ In phase/Quadrature phase
LAN Local Area Network
LNF Line Filter
LSPS Line Selector and Power Supply
M&R Measurement & Report
MON Monitor
MPDR Mid Processor/Digital Receiver
MPEP Mid Processor/Echo Processor
NTSC National Television Standards Committee
OB Obstetric
OEM Original Equipment Manufacturer (Manufacturing)
OGL Orchid Graphic Library
OS Operating System
OUTL Outlet
PAL Phase Alternation by Line
PCB Printed Circuit Board

ACUSON X300 US11-101.810.01.01.02 Page 8 of 12 Siemens


09.06 sd Medical Solutions USA, Inc.
Definitions, Acronyms and Conventions 9

PCD Power Combiner/Divider


PCI Peripheral Component Interconnect
PCIF PCI Interface
PCIMG PCI Industrial Computers Manufactures Group
PM Physio Module, Planned Maintenance
POST Power on self test
PRF Pulse Repetition Frequency
PSA Analog Power Supply
PSAC Power Supply AC tray
PSD Digital Power Supply
RACS Real Time Acoustic Control System
RC Receive beamformer and Controller
RF RadioFrequency
RGB Red Green Blue
RGLT Regulator
RM Realtime Manager (Runtime Manager)
RMP Realtime Manage Processor
ROI Region of Interest
RTC Real Time Controller
Rx Receive
RXBF Receive Beam Former
SAM Service Access Manager
SC Scan Conversion
SBC Single Board Computer
SBCR Single Board Computer Riser
SCWD Steerable Continuous Wave Doppler
SDRAM Synchronous Dynamic Random Access Memory
SIP Signal/Image Processor
SODIMM Small Outline Dual Inline Memory Module
SPC Spare Part Catalog

Siemens US11-101.810.01.01.02 Page 9 of 12 ACUSON X300


Medical Solutions USA, Inc. 09.06 sd
10 Definitions, Acronyms and Conventions

SVGA monitor Super VGA (800x600)


SWRG Switching Regulator
TBGR Time Base Generator and dRfp ( Digital RF Processor)
TGC(DGC) Time gain compensation(Depth Gain Compensation)
THI Tissue Harmonic Imaging
TI Transducer Interface
TR Transmit / Receive
TRBF Tx / Rx Beam Former
TRNS Isolation Transformer
Tx Transmit
TXPG Transmit Power Generator
TXRX Transmit / Receive Echo
USB Universal Serial Bus
VGA Video Graphic Array
VI Video IO
VP Video Processing
XGA Extended Grapics Array 1024 x768

ACUSON X300 US11-101.810.01.01.02 Page 10 of 12 Siemens


09.06 sd Medical Solutions USA, Inc.
Changes to Previous Version 11
3-
Changes to Previous Version
2Changes to Previous Version

Change(s) Description
New document Initials Release.

Siemens US11-101.810.01.01.02 Page 11 of 12 ACUSON X300


Medical Solutions USA, Inc. 09.06 sd
12 Changes to Previous Version

ACUSON X300 US11-101.810.01.01.02 Page 12 of 12 Siemens


09.06 sd Medical Solutions USA, Inc.