Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1

STAIRCASE-3 1300 4930

TPL022 10 TREADS @ 280= 2800 2130


PL5*1350 1310
NOTES

30
1. ALL DIMENSION ARE IN MILLIMETERS AND ALL LEVELS ARE IN METERS
EL.+6.450
AND CO-ORDINATES ARE IN METERS UNLESS NOTED OTHERWISE.
(MEZZANINE LVL F.F.L)
2. CIVIL & STRUCTURAL DRAWINGS SHALL BE IN CONJUNCTION
WITH MECHANICAL,ELECTRICAL,PIPING AND OTHER DICSIPLINE DWGS.
PFC-230*75*26

230
3. ALL WORKS SHALL BE IN ACCORDANCE WITH BS STANDARDS

10 RISERS @ 163= 1634


EXCEPT AS NOTED OTHERWISE ON THE DESIGN DRAWING OR
DET - 139 WITHIN SPECIFICATIONS.
TPL004
E038 ST
0
TYP. PL5*330 PF 21 4. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD.
C-
1634

TYP. 23 CONDITIONS NOT COVERED BY THE DRAWING OR SPECIFICATIONS


PFC-230*75*26 0* 7
5*2 SHALL BE BROUGHT TO THE NOTICE OF THE DESIGN ENGINEER
6

58
BEFORE PROCEEDING WITH THE CONSTRUCTION.
100
5. STRUCTURAL STEEL MEMBERS SHALL BE OF GRADE S355JR.

6. ALL CONNECTIONS ARE 8MM WELD U.N.O.


1275 10 TREADS @ 280= 2800 1427 703
7. DRAWINGS SHALL NOT BE SCALED. ONLY WRITTEN DIMENSIONS
1422 ARE FOLLOWED.

30
EL.+4.816
(2ND LANDING LVL)
TPL025
PL5*1400
PFC-230*75*26
10 RISERS @ 163= 1633

TPL023
TPL003 PL5*1400
PL5*330 KEY PLAN
4900

1633

1285 TYP.

58
6
3 5*2 100
02 0*7
ST -23
C
PF

TPL024 TPL026
10 TREADS @ 280= 2800 2130
PL5*1335 PL5*1320
30

EL.+3.183
(1ST LANDING LVL)
AMENDMENTS
REV. DATE DESCRIPTION
PFC-230*75*26

10 RISERS @ 163= 1633


TPL004 07.03.2018 ISSUED FOR APPROVAL
A
PL5*330
TYP. ST DET - 144
0
PF 22 E039
1633

C-
23 TYP.
0* 7
5*2
6
58

100 ISSUE

SUBCONTRACTORS
CONTRACTOR

TECHNOPARK
DCD
Q.S.
ST. ENG.

TRAKHEES
CLIENT

MUNICIPALITY

TENDER ISSUE
DIC
MEP
DATE

EL.+1.550
(F.F.L) 1
D-D DET - 143
SCALE 1:20 E039
E052
EL.+6.450
(MEZZANINE LVL F.F.L)

260
BE139
PFC-230*75*26

BE140
PFC-230*75*26

1634
6230
PROJECT & CLIENT

1275 10 TREADS @ 280= 2800 1427 703


PROPOSED IDS WORKSHOP
1300 830
TPL025
OILFIELDS SUPPLY CENTER LTD.
1437
PL5*1400
PLOT No. TP030501C, TCHNO PARK, DUBAI

30
EL.+4.816 CLIENT REPRESENTATIVE
(2ND LANDING LVL)
4 5*2
6 B & A ENGINEERING
02 0*7
ST -23 PFC-230*75*26 CONSULTANTS
C
PF
P.O.Box: 53363, Office 2201, Gold & Diamond Park-2
10 RISERS @ 163= 1633

Dubai, United Arab Emirates, Tel: +9714 3791883,


Fax: +9714 3791884, Web: www.badriassociates.com

58
4900

1633

CONSULTANT
100

25 1270
TPL003
PL5*330 DET - 144
TPL026
TYP. E039
PL5*1320 TYP.
Tel:04 2951822, Fax: 04 2951844, P.O Box :90201, Dubai, U.A.E
Email :designhousedubai@gmail.com www. designhouseuae.com
EL.+3.183
30

(1ST LANDING LVL) CONTRACTOR


CONTECH
PFC-230*75*26 ENGINEERING
PB.NO. 5750, DUBAI, UAE.
TEL. 04-8802662 FAX. 04-8802622

DRAWING TITLE
UC254*254*73
1633

UC254*254*73
STAIR-3 SECTIONS - 2
CN066

CN065
JOB NO. DRG.No. REVISION NORTH

E054 A
J-1654 SCALE DATE

NOTE : 1:20 07.03.2018


EL.+1.550
(F.F.L)
ALL CONNECTION DESIGN AND FABRICATION DESIGNED BY SRK
E-E
TO BE RESPONSIBLE BY CONTRACTOR'S SCALE 1:20 DRAWN BY NGP
E052
Tekla structures

DESIGNER. CHECKED BY KVR

You might also like