BNI IOL-302-002-K006

IO-Link 1.1 sensor/actuator hub


with extension port
User´s Guide
1 Contents

1 User Instructions 4
1.1. About this Manual 4
1.2. Structure of the Manual 4
1.3. Typographical Conventions 4
Enumerations 4
Actions 4
Syntax 4
Cross-references 4
1.4. Symbols 4
1.5. Abbreviations 4
2 Safety 5
2.1. Intended Use 5
1.1 Installation and Startup 5
2.2. General Safety Instructions 5
Dangerous voltage 5
3 First Steps 6
3.1. Connection overview 6
3.2. Mechanical Connection 7
3.3. Electrical Connection 7
Function ground 7
IO-Link connection 7
Connecting the sensor hub 8
Module variants 8
Digital sensors 8
Extension port 8
Extension port 9
Extension port configuration 9
4 Configuration: "Extension Off" 10
4.1. IO-Link Data 10
4.2. Process Data/ Input Data 10
4.3. Process Data/ Output Data 10
4.4. Parameter Data/ Demand Data 11
Parameter data/ demand data 11
Inversion of the inputs (40hex) 12
Configuration of inputs /outputs (41hex) 12
Safe state of outputs (42hex) 13
Safe state of the outputs on Pin 4 (42hex) 13
Safe state of the outputs on Pin 2 (43hex) 14
Voltage monitoring (44hex) 15
Monitoring the outputs (45hex) 15
Monitoring the outputs (46hex) 15
Setting the serial number (54hex) 16
Configuration of the extension port (55hex) 16
5 Configuration: Extended with BNI IOL-302-002-K006 17
5.1. IO-Link Data 17
5.2. Process Data/ Input Data 17
5.3. Process Data/ Output Data 18
5.4. Parameter Data/ Demand Data 19
Parameter Data/ Demand Data 19
Inversion of the inputs (40hex) 20
Configuration of inputs/outputs (41hex) 21
Safe state of outputs (42hex) 22
Safe state of the outputs on Pin 4 (42hex) 22
Safe state of the outputs on Pin 2 (43hex) 23
Voltage monitoring (44hex) 24
Monitoring the outputs (45hex) 24
Actuator warning (46hex) 25
Setting the serial number (54hex) 26
Configuration of the Extension port (55hex) 26
6 Configuration extended with Valve Terminal Connector with 22/24 Valves 27
6.1. IO-Link Data 27
6.2. Process Data/ Input Data 27
6.3. Process Data/ Output Data 27
6.4. Parameter Data / Demand Data 29
Parameter Data/ Demand Data 29
Inversion of the inputs (40hex) 30
Configuration of inputs/outputs (41hex) 30
Safe state of Outputs 42hex 31
Safe state of the Outputs Pin 4, 42hex 31
Safe state of the outputs on Pin 2 (43hex) 32
Voltage monitoring (44hex) 33
Monitoring the outputs (45hex) 34
Actuator warning (46hex) 34
Setting the serial number (54hex) 35
Configuration of the extension port (55hex) 35
6.5. Error Codes/ Errors 36
6.6. Events 36
7 IO-Link Functions 37
7.1. IO-Link Version 1.0/ 1.1 37
7.2. Data Storage 37
7.3. Block Configuration 37
7.4. Restoring the Factory Settings 37
8 Technical Data 38
8.1. Dimensions 38
8.2. Mechanical Data 38
8.3. Electrical Data 38
8.4. Operating conditions 38
9 Function Indicators 39
9.1. Function Indicators 39
LED indicator module status 39
Digital LED indicators for inputs/outputs 40
Extension port 40
10 Appendix 41
10.1. Type Code 41
10.2. Ordering Information 41

www.balluff.com 3
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

1 User Instructions

1.1. About this Manual This manual describes the Balluff IO-Link I/O module, also called a sensor/actuator hub.
The IO-Link protocol is used to link to the higher-level master module.
In terms of function, this compact, cost-effective module is similar to a passive splitter box; it
records digital and analog sensor signals and transmits them over the IO-Link interface. It
passes control signals coming over IO-Link to the connected actuators.

1.2. Structure of the The manual is organized so that the sections build on one another.
Manual Chapter 2: Basic safety information.
……..

1.3. Typographical The following typographical conventions are used in this manual.
Conventions

Enumerations Enumerations are shown as a list with an en-dash.


 Entry 1.
 Entry 2.

Actions Action instructions are indicated by a preceding triangle. The result of an action is indicated
by an arrow.
 Action instruction 1.
 Action result.
 Action instruction 2.

Syntax Numbers:
Decimal numbers are shown without additional indicators (e.g. 123), hexadecimal numbers
are shown with the additional indicator hex (e. g. 00hex).

Cross-references Cross-references indicate where additional information on the topic can be found (see Sec-
tion 5 "Technical Data").

1.4. Symbols Attention!


This symbol indicates a safety instruction that must be followed without exception.

Note, tip
This symbol indicates general notes.

1.5. Abbreviations BNI Balluff Network Interface


DPP Direct Parameter Page
I/O port Digital input/output port
IOL IO-Link
EMC Electromagnetic compatibility
FE Function ground
LSB Least Significant Bit
MSB Most Significant Bit
SPDU Service Protocol Data Unit

www.balluff.com 4
2 Safety

2.1. Intended Use The BNI IOL-… acts as a decentralized input/output sensor module, which is connected to a
higher-level IO-Link master module through an IO-Link interface.

1.1 Installation and Note


Startup Installation and startup must only be carried out by trained technical personnel.
Qualified personnel are people who are familiar with installation and operation of
the product and have the necessary qualifications for these tasks. Any damage
resulting from unauthorized tampering or improper use voids the manufacturer's
guarantee and warranty. The operator must ensure that appropriate safety and
accident prevention regulations are observed.

2.2. General Safety Commissioning and inspection


Instructions Before commissioning, carefully read the user's guide.
The system must not be used in applications in which the safety of persons is dependent
upon proper functioning of the device.
Authorized personnel
Installation and startup must only be carried out by trained technical personnel.
Intended use
Warranty and liability claims against the manufacturer are rendered void by:
 Unauthorized tampering
 Improper use
 Use, installation or handling contrary to the instructions provided in this user's
guide
Obligations of the operating company
The device is a piece of equipment in accordance with EMC Class A. This device can pro-
duce RF noise. The operator must take appropriate precautionary measures. The device
may only be used with an approved power supply. Only use approved cables.
Malfunctions
In the event of defects and device malfunctions that cannot be rectified, the device must be
taken out of operation and protected against unauthorized use.
Intended use is ensured only when the housing is fully installed.

Dangerous volt- Note


age Before maintenance, disconnect the device from the power supply.

Note
In the interests of product improvement, Balluff GmbH reserves the right to
change the technical data of the product and the content of this manual at any
time without notice.

www.balluff.com 5
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

3 First Steps

3.1. Connection over-


view
17
7
15 16

1 1

2
14
55
5

13 3

12 4

11 6

7
1

10 8

Figure 3-1: Connection overview BNI IOL-302-002-K006

1 Mounting hole 9 Status LED: Power supply for sensors


2 IO-Link interface 10 Standard I/O port 6
3 Standard I/O port 1 11 Standard I/O port 4
4 Standard I/O port 3 12 Standard I/O port 2
5 Status LED: Standard I/O port 5 (pin 2) 13 Standard I/O port 0
6 Standard I/O port 5 14 Label
7 Status LED: Standard I/O port 5 (pin 4) 15 Status LED IO-Link
8 Extension port or standard I/O port 7 16 Status LED power supply for actuators
17 Ground connection

www.balluff.com 6
3 First Steps

3.2. Mechanical Con- The BNI IOL modules are fastened with 3 M4 screws (position 1, Fig. 3-1/3-2).
nection

3.3. Electrical Con- The BNI IOL-302-xxx-K006 modules do not require a separate supply voltage connection.
nection Supply voltage is provided via the IO-Link interface and the higher-level IO-Link master
module.

Function ground The modules are equipped with a ground connection.

Figure 3-3: BNI ground connection IOL-302...

 Connect the sensor hub module to the ground connection.

Note!
The FE connection from the housing to the machine must have low-impedance
and be kept as short as possible.

IO-Link connec- The IO-Link connection is established via an M12 connector (A-coded, male).
tion
IO-Link (M12, A-coded, male)

Pin Requirement
1 Supply voltage for controller Us, +24 V
2 Supply voltage for actuators Ua, +24 V
3 GND, reference potential
4 C/Q, IO-Link data transmission channel

www.balluff.com 7
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

3 First Steps

Connecting the  Connect ground conductor to the FE terminal, if available.


sensor hub  Connect the incoming IO-Link cable to the sensor hub.

Note!
A standardized sensor cable is used to connect to the higher-level IO-Link master
module. Maximum length of 20 m.

Module variants Sensor hub variants Digital port


BNI IOL-302-002-K006 16 inputs/outputs, freely configurable

Digital sensors Digital input/output port (M12, A-coded, female)

Pin Requirement
1 +24 V
2 Input 2/output 2
3 0 V, GND
4 Input 1/output 1
5 FE

Note!
For the digital inputs, the input guideline specified in EN 61131-2, Type 3 applies.

Note!
Unused input port sockets must be fitted with blind caps to ensure the IP67 protec-
tion rating.

Extension port Digital input/output port (M12, A-coded, female)

Pin Requirement
1 +24 V
2 Extension port for actuator power supply
3 0 V, GND
4 Communication
5 FE

Note!
A standardized sensor cable is used to connect to the device to be extended.
Maximum length of 20 m.

www.balluff.com 8
3 First Steps

Extension port The BNI IOL-302-002-K006 module gives you the ability to use the No. 7 slot in various
ways. By default, it is used as a digital I/O slot, where both pin 2 and pin 4 can be used as a
digital input or output.
This slot can be used as an Extension port by making a corresponding entry in the parame-
ter with an index of 55hex. This makes it possible to operate one of the following modules
using the No. 7 slot.
BNI IOL-302-002-K006
BNI IOL-751-V08-K007
BNI IOL-751-V10-K007
BNI IOL-751-V13-K007

Extension port Configuration Index 0x55 value


configuration BNI IOL-302-002-K006 0
BNI IOL-302-002-K006 with BNI IOL-302-002-K006 1
BNI IOL-302-002-K006 with BNI IOL-751-V08-K007 2
BNI IOL-302-002-K006 with BNI IOL-751-V10-K007 3
BNI IOL-302-002-K006 with BNI IOL-751-V13-K007 4

Note!
The "Factory reset" command does not affect the configuration of the extension
port in any way.

www.balluff.com 9
4

Input Data

Output Data
4.1. IO-Link Data

www.balluff.com
4.3. Process Data/
4.2. Process Data/
Description

Bit
Byte
Description

Bit
Byte
7
Input Port 7 Pin 4

7
Output Port 7 Pin 4
Configuration: "Extension Off"

Transfer rate

6
Input Port 6 Pin 4

BNI IOL-302-…

6
Output Port 6 Pin 4

5
Minimum cycle time
Process data length
Input Port 5 Pin 4

5
Output Port 5 Pin 4

BNI IOL-302-000-K006

4
Input Port 4 Pin 4

4
Output Port 4 Pin 4

0
Process data length of 2 bytes:

Process data length of 2 bytes


3
Input Port 3 Pin 4

3
Output Port 3 Pin 4

3.5 ms

2
Input Port 2 Pin 4

2
Output Port 2 Pin 4 BNI IOL-302-002-K006 Extension off

1
Input Port 1 Pin 4

1
Output Port 1 Pin 4

0
Input Port 0 Pin 4

0
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

Output Port 0 Pin 4


COM2 (38.4 kbaud)

7
Input Port 7 Pin 2

7
Output Port 7 Pin 2
2 byte input, 2 byte output

6
Input Port 6 Pin 2

6
Output Port 6 Pin 2

5
Input Port 5 Pin 2

5
Output Port 5 Pin 2 4
Input Port 4 Pin 2

4
Output Port 4 Pin 2
1

1
3

Input Port 3 Pin 2

3
Output Port 3 Pin 2
2

Input Port 2 Pin 2

2
Output Port 2 Pin 2
1

Input Port 1 Pin 2

1
Output Port 1 Pin 2
0

Input Port 0 Pin 2

0
Output Port 0 Pin 2

10
4 Configuration: "Extension Off"

4.4. Parameter Data/ DPP SPDU Parameter Data Access Default value
Demand Data Index Index Sub- width rights
index
07hex
Vendor ID 2 bytes 0378hex
08hex
09hex
0Ahex Device ID 3 bytes 0x05 0B 00
0Bhex
10hex 0 Vendor name 8 bytes BALLUFF
11hex 0 Vendor text 16 bytes www.balluff.com
Product 20/24
12hex 0 BNI IOL-302-002-K006
Identification data

Read only
name bytes
13hex 0 Product ID 7 bytes BNI007Z
0 M12 sensor/actuator
14hex Product text 16 bytes
hub

15hex 0 Serial number 16 bytes 0hex

Hardware
16hex 0
revision
Firmware
17hex 0
revision

18hex Application-
0 32 bytes 0hex
specific tag

Parameter data/ DPP SPDU Parameter Data width Access rights Default
demand data Index Index Subindex Value
40hex 0
64 Inversion of the inputs 2 bytes Read/write 0hex
1-16
41hex 0
65 Config. inputs/outputs 2 bytes Read/write 0hex
1-16
42hex 0
66 Pin 4 safe state 2 bytes Read/write 0hex
1-8
Parameter data

43hex 0
67 Pin 2 safe state 2 bytes Read/write 0hex
1-8
44hex 0
68 Voltage monitoring 2 bytes Read -
1-16
45hex 0
69 Output monitoring 2 bytes Read -
1-16
46hex 0
70 Actuator warning 2 bytes Read -
1-16
54hex 0 Serial number 16 bytes Read/write 16x00hex
84
55hex 0 Extension port 1 byte Read/write 0hex
85

www.balluff.com 11
4

(41hex)
/outputs
of inputs

www.balluff.com
inputs (40hex)

Configuration
Inversion of the

Description Description

Bit
Bit

Byte
Byte

Sub-
Sub-

index
index

0 – Input
1 – Output
0 – Normal
Configuration: "Extension Off"

1 - Inverted.

8
7
8
7

Direction Port 7 Pin 4 Inversion of Port 7 Pin 4

7
6
7
6

Direction Port 6 Pin 4 Inversion of Port 6 Pin 4

Direction of port (x):


Inversion of port (x):

6
5
6
5

Direction Port 5 Pin 4 Inversion of Port 5 Pin 4

5
4
5
4

Direction Port 4 Pin 4 Inversion of Port 4 Pin 4

0
0

4
3
4
3

Direction Port 3 Pin 4 Inversion of Port 3 Pin 4

3
2
3
2

Direction Port 2 Pin 4 Inversion of Port 2 Pin 4

2
1
2
1

Direction Port 1 Pin 4 Inversion of Port 1 Pin 4


Balluff Network Interface / IO-Link BNI IOL-302-002-K006

1
0
1
0

Direction Port 0 Pin 4 Inversion of Port 0 Pin 4

7
7

Direction Port 7 Pin 2 Inversion of Port 7 Pin 2


16
16

6
6

Direction Port 6 Pin 2 Inversion of Port 6 Pin 2


15
15

5
5

Direction Port 5 Pin 2 Inversion of Port 5 Pin 2


14
14

4
4

Direction Port 4 Pin 2 Inversion of Port 4 Pin 2


13
13

1
1

3
3

Direction Port 3 Pin 2 Inversion of Port 3 Pin 2


12
12

2
2

Direction Port 2 Pin 2 Inversion of Port 2 Pin 2


11
11

1
1

Direction Port 1 Pin 2 Inversion of Port 1 Pin 2


10
10

9
0
9
0

Direction Port 0 Pin 2 Inversion of Port 0 Pin 2

12
4 Configuration: "Extension Off"

Safe state of The safe state parameter makes it possible to configure the outputs in case of a fault. If no IO-
outputs (42hex) Link communication is possible or the "valid flag" of the output process data has not been set
by the master, then each output adopts the configured status. The following statuses can be
configured for each pin.

Safe state of Byte 0 1


the outputs on
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Pin 4 (42hex)
Sub-
4 3 2 1 8 7 6 5
index
Safe state Port 3 Pin 4

Safe state Port 2 Pin 4

Safe state Port 1 Pin 4

Safe state Port 0 Pin 4

Safe state Port 7 Pin 4

Safe state Port 6 Pin 4

Safe state Port 5 Pin 4

Safe state Port 4 Pin 4


Description

www.balluff.com 13
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

4 Configuration: "Extension Off"

Safe state of Byte 0 1


the outputs
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
on Pin 2
(43hex) Subindex 4 3 2 1 8 7 6 5

Safe state Port 3 Pin 2

Safe state Port 2 Pin 2

Safe state Port 1 Pin 2

Safe state Port 0 Pin 2

Safe state Port 7 Pin 2

Safe state Port 6 Pin 2

Safe state Port 5 Pin 2

Safe state Port 4 Pin 2


Description

Value
Output state
bin dec
00 0 Output is 0V
01 1 Output is 24V
10 2 Current status is maintained
11 3 Not defined

www.balluff.com 14
4

(46hex)
(45hex)

Monitoring
Monitoring

the outputs
the outputs

www.balluff.com
toring (44hex)
Description Description Description Voltage moni-

Bit
Bit
Bit

Byte
Byte
Byte

Sub-
Sub-
Sub-

index
index
index

8
7
8
7
8
7

Warning Port 7 Pin 4 Short-circuit Port 7 Pin 4 Short-circuit Port 7 Pin 1


Configuration: "Extension Off"

7
6
7
6
7
6

Warning Port 6 Pin 4 Short-circuit Port 6 Pin 4 Short-circuit Port 6 Pin 1

6
5
6
5
6
5

Warning Port 5 Pin 4 Short-circuit Port 5 Pin 4 Short-circuit Port 5 Pin 1

5
4
5
4
5
4

Warning Port 4 Pin 4 Short-circuit Port 4 Pin 4 Short-circuit Port 4 Pin 1

0
0
0

4
3
4
3
4
3

Warning Port 3 Pin 4 Short-circuit Port 3 Pin 4 Short-circuit Port 3 Pin 1

3
2
3
2
3
2

Warning Port 2 Pin 4 Short-circuit Port 2 Pin 4 Short-circuit Port 2 Pin 1

2
1
2
1
2
1

Warning Port 1 Pin 4 Short-circuit Port 1 Pin 4 Short-circuit Port 1 Pin 1

1
0
1
0
1
0

Warning Port 0 Pin 4 Short-circuit Port 0 Pin 4 Short-circuit Port 0 Pin 1

7
7
7

Warning Port 7 Pin 2 Short-circuit Port 7 Pin 2 -

16
16
16

6
6
6

Warning Port 6 Pin 2 Short-circuit Port 6 Pin 2 -

15
15

5
5
5

Warning Port 5 Pin 2 Short-circuit Port 5 Pin 2 -

14
14

4
4
4

Warning Port 4 Pin 2 Short-circuit Port 4 Pin 2

13
13

1
1
1

3
3
3

Warning Port 3 Pin 2 Short-circuit Port 3 Pin 2 -

12
12

2
2
2

Warning Port 2 Pin 2 Short-circuit Port 2 Pin 2 Undervoltage Ua

11
11
11

1
1
1

Warning Port 1 Pin 2 Short-circuit Port 1 Pin 2 -

10
10

9
0
9
0
9
0

Warning Port 0 Pin 2 Short-circuit Port 0 Pin 2 Undervoltage Us

15
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

4 Configuration: "Extension Off"

Setting the se- The serial number has a default value of 16x00hex.
rial number In order to use the "Identity" master validation mode, a serial number can be set using this
(54hex) parameter.
This prevents a device from connecting to the wrong master port.

Configuration Configuration Index 0x55 value


of the exten- BNI IOL-302-002-K006 0
sion port
BNI IOL-302-002-K006 with BNI IOL-302-002-
(55hex) 1
K006
BNI IOL-302-002-K006 with BNI IOL-751-V08-
2
K007
BNI IOL-302-002-K006 with BNI IOL-751-V10-
3
K007
BNI IOL-302-002-K006 with BNI IOL-751-V13-
4
K007

Note!
The "Factory reset" command does not affect the configuration of the extension port in
any way.

www.balluff.com 16
5

Input Data
5.1. IO-Link Data

www.balluff.com
5.2. Process Data/

Bit
Bit
Description Description

Byte
Byte
Input Input

7
7
Port 7 pin 4 Port 7 pin 4

Transfer rate
Input Input

6
6
Port 6 pin 4 Port 6 pin 4
Input Input

5
5
Minimum cycle time
Process data length
Port 5 pin 4 Port 5 pin 4
Input Input

4
4
Port 4 pin 4 Port 4 pin 4

2
0
Process data length of 4 bytes:
Input Input

3
3
Configuration: Extended with BNI IOL-302-002-K006

Port 3 pin 4 Port 3 pin 4

4.5 ms
Input Input

2
2
Port 2 pin 4 Port 2 pin 4
Input Input

1
1
Port 1 pin 4 Port 1 pin 4
Input Input

0
0
Port 0 pin 4 Port 0 pin 4
Input Input COM2 (38.4 kbaud)

7
7
Port 7 pin 2 Port 7 pin 2
4 byte input, 4 byte output

Extension port
Input Input

6
6
Port 6 pin 2 Port 6 pin 2
Input Input

5
5
BNI IOL-302-002-K006 extended with BNI IOL-302-002-K006

Port 5 pin 2 Port 5 pin 2


Input Input

4
4
Port 4 pin 2 Port 4 pin 2

3
1
Input Input

3
Port 3 pin 2 Port 3 pin 2 3
Input Input

2
2

Port 2 pin 2 Port 2 pin 2


Input Input

1
1

Port 1 pin 2 Port 1 pin 2


Input Input

0
0

Port 0 pin 2 Port 0 pin 2

17
5

Output Data

www.balluff.com
5.3. Process Data/
Description Description

Bit
Bit

Byte
Byte

7
7
Output Port 7 Pin 4 Output Port 7 Pin 4

6
6

Output Port 6 Pin 4 Output Port 6 Pin 4

5
5

Output Port 5 Pin 4 Output Port 5 Pin 4

4
4

Output Port 4 Pin 4 Output Port 4 Pin 4

2
0
Process data length of 4 bytes

3
3

Output Port 3 Pin 4 Output Port 3 Pin 4


Configuration: Extended with BNI IOL-302-002-K006

2
2

Output Port 2 Pin 4 Output Port 2 Pin 4

1
1

Output Port 1 Pin 4 Output Port 1 Pin 4


0
0

Output Port 0 Pin 4 Output Port 0 Pin 4


Balluff Network Interface / IO-Link BNI IOL-302-002-K006

7
7

Output Port 7 Pin 2 Output Port 7 Pin 2


6
6

Extension port

Output Port 6 Pin 2 Output Port 6 Pin 2


5
5

Output Port 5 Pin 2 Output Port 5 Pin 2


4
4

Output Port 4 Pin 2 Output Port 4 Pin 2


3
1

3
3

Output Port 3 Pin 2 Output Port 3 Pin 2


2
2

Output Port 2 Pin 2 Output Port 2 Pin 2


1
1

Output Port 1 Pin 2 Output Port 1 Pin 2


0
0

Output Port 0 Pin 2 Output Port 0 Pin 2

18
5 Configuration: Extended with BNI IOL-302-002-K006

5.4. Parameter Data/ DPP SPDU Parameter Data Access Default value
Demand Data Index Index Sub- width rights
index
07hex
Vendor ID 2 bytes 0378hex
08hex
09hex
0Ahex Device ID 3 bytes 0x05 0B 01
0Bhex
10hex 0 Vendor Name 8 bytes Balluff
11hex 0 Vendor text 16 bytes www.balluff.com
20/24 BNI IOL-302-002-K006
Product
12hex 0 Byte with BNI IOL-302-002-
Name
Identification data

Read only
K006

13hex 0 Product ID 7 bytes BNI007Z

M12 sensor/actuator
14hex 0 Product text 16 bytes
hub
15hex 0 Serial number 16 bytes 0hex

Hardware
16hex 0
revision
Firmware
17hex 0
revision

18hex Application-
0 32 bytes 0hex
specific tag

Parameter Data/ DPP SPDU Parameter Data width Access rights Default
Demand Data Index Index Subindex Value
40hex 0
64 Inversion of the inputs 4 bytes Read/write 0hex
1-32
41hex 0
65 Config. inputs/outputs 4 bytes Read/write 0hex
1-32
42hex 0
66 Safe state Pin 4 4 bytes Read/write 0hex
1-16
Parameter data

43hex 0
67 Safe state Pin 2 4 bytes Read/write 0hex
1-16
44hex 0
68 Voltage monitoring 4 bytes Read -
1-32
45hex 0
69 Output monitoring 4 bytes Read -
1-32
46hex 0
70 Actuator warning 4 bytes Read -
1-32
54hex 0 Serial number 16 bytes Read/write 16x00hex
84
55hex 0 Extension port 1 byte Read/write 1hex
85

www.balluff.com 19
5

www.balluff.com
inputs (40hex)
Inversion of the

Description Description

Bit
Bit

Byte
Byte

Sub-
Sub-

index
index

0 – Normal
1 - Inverted
* No function

7
8
7

Inversion of Port 7 Pin 4 * Inversion of Port 7 Pin 4

24
6
7
6

Inversion of Port 6 Pin 4 Inversion of Port 6 Pin 4

23

Inversion of port (x):


5
6
5

Inversion of Port 5 Pin 4 Inversion of Port 5 Pin 4

22
4
5
4

Inversion of Port 4 Pin 4 Inversion of Port 4 Pin 4

21
2
0

3
4
3
Configuration: Extended with BNI IOL-302-002-K006

Inversion of Port 3 Pin 4 Inversion of Port 3 Pin 4

20
2
3
2

Inversion of Port 2 Pin 4 Inversion of Port 2 Pin 4

19
1
2
1

Inversion of Port 1 Pin 4 Inversion of Port 1 Pin 4

18
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

0
1
0

Inversion of Port 0 Pin 4 Inversion of Port 0 Pin 4

17
7
7

Inversion of Port 7 Pin 2 32 Inversion of Port 7 Pin 2


16

Extension port
6
6

Inversion of Port 6 Pin 2 Inversion of Port 6 Pin 2


31
15

5
5

Inversion of Port 5 Pin 2 Inversion of Port 5 Pin 2


30
14

4
4

Inversion of Port 4 Pin 2 Inversion of Port 4 Pin 2


29
13

3
1

3
3

Inversion of Port 3 Pin 2 Inversion of Port 3 Pin 2


28
12

2
2

Inversion of Port 2 Pin 2 Inversion of Port 2 Pin 2


27
11

1
1

Inversion of Port 1 Pin 2 Inversion of Port 1 Pin 2


26
10

0
9
0

Inversion of Port 0 Pin 2 Inversion of Port 0 Pin 2


25

20
5

of in-

(41hex)
puts/outputs

www.balluff.com
Configuration
Description Description

Bit
Bit

Su-
Su-

Byte
Byte

bindex
bindex

0 - Normal
1 - Inverted
* No function

7
8
7

Direction Port 7 Pin 4 * Direction Port 7 Pin 4

24
6
7
6

Direction Port 6 Pin 4 Direction Port 6 Pin 4

23

Inversion of port (x):


5
6
5

Direction Port 5 Pin 4 Direction Port 5 Pin 4

22
4
5
4

Direction Port 4 Pin 4 Direction Port 4 Pin 4

21
2
0

3
4
3
Configuration: Extended with BNI IOL-302-002-K006

Direction Port 3 Pin 4 Direction Port 3 Pin 4

20
2
3
2

Direction Port 2 Pin 4 Direction Port 2 Pin 4

19
1
2
1

Direction Port 1 Pin 4 Direction Port 1 Pin 4

18
0
1
0

Direction Port 0 Pin 4 Direction Port 0 Pin 4

17
7
7

Direction Port 7 Pin 2 32 * Direction Port 7 Pin 2


16

Extension port
6
6

Direction Port 6 Pin 2 Direction Port 6 Pin 2


31
15

5
5

Direction Port 5 Pin 2 Direction Port 5 Pin 2


30
14

4
4

Direction Port 4 Pin 2 Direction Port 4 Pin 2


29
13

3
1

3
3

Direction Port 3 Pin 2 Direction Port 3 Pin 2


28
12

2
2

Direction Port 2 Pin 2 Direction Port 2 Pin 2


27
11

1
1

Direction Port 1 Pin 2 Direction Port 1 Pin 2


26
10

0
9
0

Direction Port 0 Pin 2 Direction Port 0 Pin 2


25

21
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

5 Configuration: Extended with BNI IOL-302-002-K006

Safe state of The safe state parameter makes it possible to configure the outputs in case of a fault. If no IO-
outputs (42hex) Link communication is possible or the "valid flag" of the output process data has not been set
by the master, then each output adopts the configured status. The following statuses can be
configured for each pin.

Safe state of Byte 0 1


the outputs on
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Pin 4 (42hex)
Sub-
4 3 2 1 8 7 6 5
index
Safe state Port 3 Pin 4

Safe state Port 2 Pin 4

Safe state Port 1 Pin 4

Safe state Port 0 Pin 4

Safe state Port 7 Pin 4

Safe state Port 6 Pin 4

Safe state Port 5 Pin 4

Safe state Port 4 Pin 4


Description

Byte 2 3
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Sub-
12 11 10 9 16 15 14 13
index
Extension port
* Safe state Port 7 Pin 4
Safe state Port 3 Pin 4

Safe state Port 2 Pin 4

Safe state Port 1 Pin 4

Safe state Port 0 Pin 4

Safe state Port 6 Pin 4

Safe state Port 5 Pin 4

Safe state Port 4 Pin 4


Description

* No function

www.balluff.com 22
5

(43hex)
on Pin 2
the outputs
Safe state of

www.balluff.com
Description Description

Bit
Bit

11
10
01
00
bin
Byte
Byte

Subindex
Subindex

* No function
7
7

Value
4
Safe state Port 3 Pin 2 Safe state Port 3 Pin 2

12

3
2
1
0
6
6

dec
5
5

Safe state Port 2 Pin 2 Safe state Port 2 Pin 2

11
4
4

2
0

3
3

Safe state Port 1 Pin 2 Safe state Port 1 Pin 2

10
Configuration: Extended with BNI IOL-302-002-K006

2
2

Output is 0V

Not permitted
Output is 24V
1
1

9
1

Safe state Port 0 Pin 2 Safe state Port 0 Pin 2

0
0

7
7

Current status is maintained


8

* Safe state Port 7 Pin 2 Safe state Port 7 Pin 2

16
6
6

Output state
5
5

Safe state Port 6 Pin 2 Safe state Port 6 Pin 2


15
4
4

3
1

3
3

Safe state Port 5 Pin 2 Safe state Port 5 Pin 2


14
2
2

1
1

Safe state Port 4 Pin 2 Safe state Port 4 Pin 2


13
0
0

23
5

www.balluff.com
toring (44hex)
Voltage moni-

Monitoring the
outputs (45hex)
Description

Bit
Description Description

Bit
Bit

dex
dex

Byte

Sub-
Byte
Byte

index
Subin-
Subin-

8
7

* No function
7
8
7

* Short-circuit Port 7 Pin 4 Short-circuit Port 7 Pin 1 Short-circuit Port 7 Pin 1

24

7
6
6
7
6

Short-circuit Port 6 Pin 4 Short-circuit Port 6 Pin 1 Short-circuit Port 6 Pin 1

23

6
5
5
6
5

Short-circuit Port 5 Pin 4 Short-circuit Port 5 Pin 1 Short-circuit Port 5 Pin 1

22

5
4
4
5
4

Short-circuit Port 4 Pin 4 Short-circuit Port 4 Pin 1 Short-circuit Port 4 Pin 1

21

0
2
0

4
3
3
4
3

Short-circuit Port 3 Pin 4 Short-circuit Port 3 Pin 1 Short-circuit Port 3 Pin 1

20
Configuration: Extended with BNI IOL-302-002-K006

3
2
2
3
2

Short-circuit Port 2 Pin 4 Short-circuit Port 2 Pin 1 Short-circuit Port 2 Pin 1

19

2
1
1
2
1

Short-circuit Port 1 Pin 4 Short-circuit Port 1 Pin 1 Short-circuit Port 1 Pin 1

18
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

1
0
0
1
0

Short-circuit Port 0 Pin 4 Short-circuit Port 0 Pin 1 Short-circuit Port 0 Pin 1


17

7
7
7

* Short-circuit Port 7 Pin 2 - -

16
32

Extension port

6
6
6

Short-circuit Port 6 Pin 2 - -

15
31

5
5
5

Short-circuit Port 5 Pin 2 - -

14
30

4
4
4

Short-circuit Port 4 Pin 2

13
29

- -

1
3
1

3
3
3

Short-circuit Port 3 Pin 2

12
28

- -

2
2
2

Short-circuit Port 2 Pin 2

11
27
11

Undervoltage Ua Undervoltage Ua

1
1
1

Short-circuit Port 1 Pin 2

10
26

- -

9
0
0
9
0

Short-circuit Port 0 Pin 2 Undervoltage Us Undervoltage Us


25

24
5

ing (46hex)

www.balluff.com
Actuator warn-
Description Description Description

Bit
Bit
Bit

Byte
Byte
Byte

Subindex
Subindex
Subindex

* No function

7
8
7
7

Warning Port 7 Pin 4 * Warning Port 7 Pin 4 Short-circuit Port 7 Pin 4

24
24

6
7
6
6

Warning Port 6 Pin 4 Warning Port 6 Pin 4 Short-circuit Port 6 Pin 4

23
23

5
6
5
5

Warning Port 5 Pin 4 Warning Port 5 Pin 4 Short-circuit Port 5 Pin 4

22
22

4
5
4
4

Warning Port 4 Pin 4 Warning Port 4 Pin 4 Short-circuit Port 4 Pin 4

21
21

2
0
2
Configuration: Extended with BNI IOL-302-002-K006

3
4
3
3

Warning Port 3 Pin 4 Warning Port 3 Pin 4 Short-circuit Port 3 Pin 4

20
20

2
3
2
2

Warning Port 2 Pin 4 Warning Port 2 Pin 4 Short-circuit Port 2 Pin 4

19
19

1
2
1
1

Warning Port 1 Pin 4 Warning Port 1 Pin 4 Short-circuit Port 1 Pin 4

18
18

0
1
0
0

Warning Port 0 Pin 4 Warning Port 0 Pin 4 Short-circuit Port 0 Pin 4

17
17

7
7
7

Warning Port 7 Pin 2 * Warning Port 7 Pin 2 Short-circuit Port 7 Pin 2

32
16
32

Extension port
Extension port

6
6
6

Warning Port 6 Pin 2 Warning Port 6 Pin 2 Short-circuit Port 6 Pin 2

31
15
31

5
5
5

Warning Port 5 Pin 2 Warning Port 5 Pin 2 Short-circuit Port 5 Pin 2

30
14
30

4
4
4

Warning Port 4 Pin 2 Warning Port 4 Pin 2 Short-circuit Port 4 Pin 2

29
13
29

3
1
3

3
3
3

Warning Port 3 Pin 2 Warning Port 3 Pin 2 Short-circuit Port 3 Pin 2

28
12
28

2
2
2

Warning Port 2 Pin 2 Warning Port 2 Pin 2 Short-circuit Port 2 Pin 2

27
11
27

1
1
1

Warning Port 1 Pin 2 Warning Port 1 Pin 2 Short-circuit Port 1 Pin 2

26
10
26

0
9
0
0

Warning Port 0 Pin 2 Warning Port 0 Pin 2 Short-circuit Port 0 Pin 2

25
25

25
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

5 Configuration: Extended with BNI IOL-302-002-K006

Setting the se- The serial number has a default value of 16x00hex.
rial number In order to use the "Identity" master validation mode, a serial number can be set using this
(54hex) parameter.
This prevents a device from connecting to the wrong master port.

Configuration Configuration Index 0x55 value


of the Exten- BNI IOL-302-002-K006 0
sion port
BNI IOL-302-002-K006 with BNI IOL-302-002-K006 1
(55hex)
BNI IOL-302-002-K006 with BNI IOL-751-V08-K007 2
BNI IOL-302-002-K006 with BNI IOL-751-V10-K007 3
BNI IOL-302-002-K006 with BNI IOL-751-V13-K007 4

Note!
The "Factory reset" command does not affect the configuration of the extension port
in any way.

www.balluff.com 26
6

Input Data

Output Data
6.1. IO-Link Data

www.balluff.com
6.3. Process Data/
6.2. Process Data/

Bit
Description Description

Bit
Byte

Byte
7

7
Output Port 7 Pin 4 Input Port 7 Pin 4

Transfer rate

6
Output Port 6 Pin 4 Input Port 6 Pin 4

Minimum cycle time


Process data length

5
Output Port 5 Pin 4 Input Port 5 Pin 4

4
Output Port 4 Pin 4 Input Port 4 Pin 4

0
Process data length of 6 bytes
Process data length of 2 bytes:

3
Output Port 3 Pin 4 Input Port 3 Pin 4

4.5 ms

2
Input Port 2 Pin 4

2
Output Port 2 Pin 4

1
Input Port 1 Pin 4

1
Output Port 1 Pin 4

0
Input Port 0 Pin 4

0
COM2 (38.4 kbaud)
Output Port 0 Pin 4

7
Input Port 7 Pin 2

7
Output Port 7 Pin 2

2 byte input, 6 byte output


Configuration extended with Valve Terminal Connector with 22/24 Valves

6
Output Port 6 Pin 2 Input Port 6 Pin 2

5
Output Port 5 Pin 2 Input Port 5 Pin 2

4
Output Port 4 Pin 2 Input Port 4 Pin 2
1

1
3

3
Output Port 3 Pin 2 Input Port 3 Pin 2 2

2
Output Port 2 Pin 2 Input Port 2 Pin 2
1

1
Output Port 1 Pin 2 Input Port 1 Pin 2
BNI IOL-302-002-K006, extended with valve terminal connector with 22/24 valves

0
Output Port 0 Pin 2 Input Port 0 Pin 2

27
6

www.balluff.com
Description Description

Bit
Bit

Byte
Byte

7
7

- -

6
6

- -

* No function for V013


* No function for V013

5
5

- -

4
4

- -

4
2

3
3

* Valve 12 – Coil B * Valve 12 – Coil A

2
2

Valve 11 – Coil B Valve 11 – Coil A

1
1

Valve 10 – Coil B Valve 10 – Coil A


Balluff Network Interface / IO-Link BNI IOL-302-002-K006

0
0

Valve 09 – Coil B Valve 09 – Coil A


7
7

Valve 08 – Coil B Valve 08 – Coil A


Configuration extended with Valve Terminal Connector with 22/24 Valves

Extension port
6

Valve 07 – Coil B
6

Valve 07 – Coil A
5

Valve 06 – Coil B
5

Valve 06 – Coil A
Valve terminal on the Extension port

Valve 05 – Coil B
4

Valve 05 – Coil A
5
3

Valve 04 – Coil B
3

Valve 04 – Coil A
2

Valve 03 – Coil B
2

Valve 03 – Coil A
1

Valve 02 – Coil B
1

Valve 02 – Coil A
0

Valve 01 – Coil B
0

Valve 01 – Coil A

28
6 Configuration extended with Valve Terminal Connector with 22/24 Valves

6.4. Parameter Data DPP SPDU Parameter Data Access Default value
/ Demand Data Index Index Sub- width rights
index
07hex
Vendor ID 2 bytes 0378hex
08hex
09hex 0x05 0B 02
0Ahex Device ID 3 bytes 0x05 0B 03
0Bhex 0x05 0B 04
10hex 0 Vendor Name 8 bytes Balluff
11hex 0 Vendor text 16 bytes www.balluff.com
BNI IOL-302-002-K006
with BNI IOL-751-V08-
K007
BNI IOL-302-002-K006
Product 20/24
12hex 0 with BNI IOL-751-V10-
name bytes
K007
BNI IOL-302-002-K006
with BNI IOL-751-V13-
K007
Identification data

Read only
BNI005L (302-002-K006)
13hex 0 Product ID 7 bytes

Sensor/actuator hub M12


with expanded BNI IOL-
751-V08-K007
Sensor/actuator hub M12
14hex 0 Product text 16 bytes with Extended BNI IOL-
751-V10-K007
Sensor/actuator hub M12
with Extended BNI IOL-
751-V13-K007
15hex 0 Serial number 16 bytes 0hex
Hardware
16hex 0
revision
Firmware
17hex 0
revision
Application-
18hex 0 32 bytes 0hex
specific tag

Parameter Data/ DPP SPDU Parameter Data width Access rights Default
Demand Data Index Index Subindex Value
40hex 0
64 Inversion of the inputs 2 bytes Read/write 0hex
1-16
41hex 0
65 Config. inputs/outputs 2 bytes Read/write 0hex
1-16
42hex 0
66 Safe state on Pin 4 10 bytes Read/write 0hex
1-32
Parameter data

43hex 0
67 Safe state on Pin 2 2 bytes Read/write 0hex
1-8
44hex 0
68 Voltage monitoring 3 bytes Read -
1-23
45hex 0
69 Output monitoring 6 bytes Read -
1-40
46hex 0
70 Actuator warning 2 bytes Read -
1-16
54hex 0 Serial number 16 bytes Read/write 16x00hex
84
55hex 0 Extension port 1 byte Read/write 2, 3, 4hex
85

www.balluff.com 29
6

of in-

(41hex)
puts/outputs

www.balluff.com
inputs (40hex)

Configuration
Inversion of the

Description Description

Bit
Bit

Su-
Byte
Byte

Sub-
index

bindex

0 - Normal
0 - Normal

1 - Inverted
1 - Inverted

8
7
8
7

Direction Port 7 Pin 4 Inversion of Port 7 Pin 4

7
6
7
6

Direction Port 6 Pin 4 Inversion of Port 6 Pin 4

Inversion of port (x):


Inversion of port (x):

6
5
6
5

Direction Port 5 Pin 4 Inversion of Port 5 Pin 4

5
4
5
4

Direction Port 4 Pin 4 Inversion of Port 4 Pin 4

0
0

4
3
4
3

Direction Port 3 Pin 4 Inversion of Port 3 Pin 4

3
2
3
2

Direction Port 2 Pin 4 Inversion of Port 2 Pin 4

2
1
2
1

Direction Port 1 Pin 4 Inversion of Port 1 Pin 4


Balluff Network Interface / IO-Link BNI IOL-302-002-K006

1
0
1
0

Direction Port 0 Pin 4 Inversion of Port 0 Pin 4


7
7

Direction Port 7 Pin 2 Inversion of Port 7 Pin 2


16
16
Configuration extended with Valve Terminal Connector with 22/24 Valves

6
6

Direction Port 6 Pin 2 Inversion of Port 6 Pin 2


15
15

5
5

Direction Port 5 Pin 2 Inversion of Port 5 Pin 2


14
14

4
4

Direction Port 4 Pin 2 Inversion of Port 4 Pin 2


13
13

1
1

3
3

Direction Port 3 Pin 2 Inversion of Port 3 Pin 2


12
12

2
2

Direction Port 2 Pin 2 Inversion of Port 2 Pin 2


11
11

1
1

Direction Port 1 Pin 2 Inversion of Port 1 Pin 2


10
10

9
0
9
0

Direction Port 0 Pin 2 Inversion of Port 0 Pin 2

30
6 Configuration extended with Valve Terminal Connector with 22/24 Valves

Safe state of The safe state parameter makes it possible to configure the outputs in case of a fault. If no IO-
Outputs 42hex Link communication is possible or the "valid flag" of the output process data has not been set
by the master, then each output adopts the configured status. The following statuses can be
configured for each pin.

Safe state of Byte 0 1


the Outputs Pin
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
4, 42hex
Sub-
4 3 2 1 8 7 6 5
index
Safe state Port 3 Pin 4

Safe state Port 2 Pin 4

Safe state Port 1 Pin 4

Safe state Port 0 Pin 4

Safe state Port 7 Pin 4

Safe state Port 6 Pin 4

Safe state Port 5 Pin 4

Safe state Port 4 Pin 4


Description

Byte 2 3
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Sub-
31 29 27 25
index

Valve terminal on the extension port


* Valve 12 – Coil A

Valve 11 – Coil A

Valve 10 – Coil A

Valve 09 – Coil A
Description

* No function for V013

Byte 4 5
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Sub-
23 21 19 17 15 13 11 9
index

Valve terminal on the extension port


Valve 08 – Coil A

Valve 07 – Coil A

Valve 06 – Coil A

Valve 05 – Coil A

Valve 04 – Coil A

Valve 03 – Coil A

Valve 02 – Coil A

Valve 01 – Coil A
Description

www.balluff.com 31
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

6 Configuration extended with Valve Terminal Connector with 22/24 Valves

Byte 6 7
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Sub-
32 30 28 26
index

Valve terminal on the extension port

* Valve 12 – Coil B

Valve 11 – Coil B

Valve 10 – Coil B

Valve 09 – Coil B
Description

-
* No function for V013

Byte 8 9
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Sub-
24 22 20 18 16 14 12 10
index
Valve terminal on the extension port
Valve 08 – Coil B

Valve 07 – Coil B

Valve 06 – Coil B

Valve 05 – Coil B

Valve 04 – Coil B

Valve 03 – Coil B

Valve 02 – Coil B

Valve 01 – Coil B
Description

Safe state of Byte 0 1


the outputs on
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Pin 2 (43hex)
Subindex 4 3 2 1 8 7 6 5
Safe state Port 2 Pin 2
Safe state Port 3 Pin 2

Safe state Port 1 Pin 2

Safe state Port 0 Pin 2

Safe state Port 7 Pin 2

Safe state Port 6 Pin 2

Safe state Port 5 Pin 2

Safe state Port 4 Pin 2


Description

Value
Output state
bin dec
00 0 Output is 0V
01 1 Output is 24V
10 2 Current status is maintained
11 3 Not defined

www.balluff.com 32
6

www.balluff.com
toring (44hex)
Voltage moni-
Description Description
Bit

Bit
dex
Byte

Byte

Sub-
index
Subin-
8
7

7
- Short-circuit Port 7 Pin 1
7
6

6
Overload UA Short-circuit Port 6 Pin 1

23
6
5

Short-circuit Port 5 Pin 1

5
-
5
4

Short-circuit Port 4 Pin 1

4
-
0

2
4
3

Short-circuit Port 3 Pin 1

3
-
3
2

Short-circuit Port 2 Pin 1

2
Undervoltage UA

19
2
1

Short-circuit Port 1 Pin 1

1
-
1
0

Valve terminal on the extension port


Short-circuit Port 0 Pin 1
0
Undervoltage US

17
7

-
16
Configuration extended with Valve Terminal Connector with 22/24 Valves

-
5

-
4

-
1
3

-
2

Undervoltage Ua
11
1

-
9
0

Undervoltage Us

33
6

(46hex)
(45hex)

warning
Actuator
Monitoring
the outputs

www.balluff.com
Description Description Description

Bit
Bit
Bit

Byte
Byte
Byte

Description

Sub-
Sub-
Sub-

Bit

index
index
index

Byte

Subindex

8
7
7
8
7

Warning Port 7 Pin 4 - Short-circuit Port 7 Pin 4

7
-

7
6
6
7
6

Warning Port 6 Pin 4 - Short-circuit Port 6 Pin 4

* No function for V013


* No function for V013

6
-

6
5
5
6
5

Warning Port 5 Pin 4 - Short-circuit Port 5 Pin 4

5
-

5
4
4
5
4

Warning Port 4 Pin 4 - Short-circuit Port 4 Pin 4

4
-

0
2
0

4
3
3
4
3

Warning Port 3 Pin 4 * Valve 12 – Coil A Short-circuit Port 3 Pin 4

39

3
* Valve 12 – Coil B

40

3
2
2
3
2

Warning Port 2 Pin 4 Valve 11 – Coil A Short-circuit Port 2 Pin 4

37

2
Valve 11 – Coil B

38

2
1
1
2
1

Warning Port 1 Pin 4 Valve 10 – Coil A Short-circuit Port 1 Pin 4


35

1
Valve 10 – Coil B

36
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

1
0
0
1
0

Warning Port 0 Pin 4 Valve 09 – Coil A Short-circuit Port 0 Pin 4


33

0
Valve 09 – Coil B

34

7
7
7

Warning Port 7 Pin 2 Valve 08 – Coil A Short-circuit Port 7 Pin 2

16
31
16

7
Valve 08 – Coil B

32
Configuration extended with Valve Terminal Connector with 22/24 Valves

Extension port

6
6
6

Extension port
Warning Port 6 Pin 2 Valve 07 – Coil A Short-circuit Port 6 Pin 2

15
29
15

6
Valve 07 – Coil B

30

5
5
5

Warning Port 5 Pin 2 Valve 06 – Coil A Short-circuit Port 5 Pin 2

14
27
14

5
Valve 06 – Coil B

28

4
4
4

Warning Port 4 Pin 2 Valve 05 – Coil A Short-circuit Port 4 Pin 2

13
25
13

4
Valve 05 – Coil B

26

1
3
1

3
3
3

Warning Port 3 Pin 2 Valve 04 – Coil A Short-circuit Port 3 Pin 2

12
23
12

3
Valve 04 – Coil B

24

2
2
2

Warning Port 2 Pin 2


2 Valve 03 – Coil A Short-circuit Port 2 Pin 2

11
21
11

Valve 03 – Coil B
22

1
1
1

Warning Port 1 Pin 2 Valve 02 – Coil A Short-circuit Port 1 Pin 2

10
19
10

Valve 02 – Coil B
20

9
0
0
9
0

Warning Port 0 Pin 2 Valve 01 – Coil B Valve 01 – Coil A Short-circuit Port 0 Pin 2
17

18

34
6 Configuration extended with Valve Terminal Connector with 22/24 Valves

Setting the se- The serial number has a default value of 16x00hex.
rial number In order to use the "Identity" master validation mode, a serial number can be set using this
(54hex) parameter.
This prevents a device from connecting to the wrong master port.

Configuration Configuration Index 0x55 value


of the exten- BNI IOL-302-002-K006 0
sion port
BNI IOL-302-002-K006 with BNI IOL-302-002-K006 1
(55hex)
BNI IOL-302-002-K006 with BNI IOL-751-V08-K007 2
BNI IOL-302-002-K006 with BNI IOL-751-V10-K007 3
BNI IOL-302-002-K006 with BNI IOL-751-V13-K007 4

Note!
The "Factory reset" command does not affect the configuration of the extension port
in any way.

www.balluff.com 35
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

6 Configuration extended with Valve Terminal Connector with 22/24 Valves

6.5. Error Codes/ Error code Description


Errors 0x8011 Index not available
0x8012 Subindex not available
0x8023 Access denied
0x8033 Parameter length overrun
0x8034 Parameter length underrun
0x8035 Function not available

6.6. Events IO-Link Revision 1.0


Event code Description
0x5112 Low sensor voltage (US)
0x5114 Low actuator voltage (UA)
0x5410 Output stages
0x8DF0 Retry at the extension port
0x8DF1 Device lost at the extension port
0x8DF2 Wrong device at the extension port
IO-Link Revision 1.1
Event code Description
0x5111 Low sensor voltage (US)
0x5112 Low actuator voltage (UA)
0x7710 Short circuit
0x8DF0 Retry at the extension port
0x8DF1 Device lost at the extension port
0x8DF2 Wrong device at the extension port

www.balluff.com 36
7 IO-Link Functions

7.1. IO-Link Ver- This device can be operated with an IO-Link master according to IO-Link version 1.0, and ver-
sion 1.0/ sion 1.1. Version-specific functions such as data storage (version 1.1) are only supported in
1.1 combination with a suitable IO-Link master.

7.2. Data Storage Each IO-Link master of IO-Link version 1.1 features data storage in which an image of the IO-
Link device configuration can be stored. When a device is replaced, the stored configuration is
automatically transferred to the new device. This guarantees minimal downtime. Validation must
be switched on in order to use the data storage. For information about the configuration of data
storage and validation, please refer to the operating manual of the respective IO-Link master.

7.3. Block Config- The device supports block configuration. This allows all parameters in a data block to be con-
uration sistently imported from a controller or a configuration tool into the device.

7.4. Restoring the The factory settings on the device can be restored by carrying out the "restore factory settings"
Factory Set- system command.
tings 0x82 must be written to Index 2 Subindex 0 for the command.

www.balluff.com 37
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

8 Technical Data

8.1. Dimensions

8.2. Mechanical Data Housing material Plastic, transparent


IO-Link port IO-Link port M12, A-coded, male
I/O ports M12x1, A-coded, female (8 piece)
Weight 90 g
Dimension (L × W × H, without connect-
115 × 50 × 30.8 mm
or)
8.3. Electrical Data Supply voltage 18–30.2 V DC, corresponding to EN 61131-2
Ripple < 1%
Current consumption without load ≤ 65 mA
Load current (PIN 1) Max. 200 mA (temperature-dependent)
Load current per output (PIN 2.4) Max. 300 mA (temperature-dependent)
Inputs PNP, type 3

8.4. Operating condi- Operating temperature –5 °C … +55 °C


tions Storage temperature –25 °C … +70 °C
EMC
Immunity tests: EN 61000-6-2:2005 AC:2005
Emission tests: EN 61000-6-4:2007 A1:2011
IP67 (only in plugged-in and screwed
Degree of protection
state)
Vibration/shock EN 60068 Part 2-6/27

www.balluff.com 38
9 Function Indicators

9.1. Function Indica-


tors

COM UA

LED 1

LED 2

US

LED indicator Indicator Function


module status IO-Link communica- Green No communication
tion
Green, negatively pulsed Communication OK
Red Communication overload
Off Module is without voltage

Us LED Green Sensor power supply is OK


Green, flashing slowly Sensor power supply short-circuit
Green, flashing quickly Undervoltage < 18 V
Off Module is without voltage

Ua LED Green Actuator power supply is OK


Green, flashing slowly Actuator short circuit
Green, flashing quickly Undervoltage < 18 V
Off No actuator power supply

www.balluff.com 39
Balluff Network Interface / IO-Link BNI IOL-302-002-K006

9 Function Indicators

Digital LED LED 2, input/output on Pin 4 and LED 1, input/output on Pin 2


indicators for
inputs/outputs Indicator Request / Signal
Yellow Input/output signal = 1
Sensor power supply short-circuit,
Red actuator warning
actuator short circuit
Off Input/output signal = 0

Extension port The table is valid if the extension port is active. If the extension port is used as a standard I/O,
then the description from "Digital LED indicators for inputs/outputs" can be used.

Status Function
Green IO-Link – connection active
Green, flashing No IO-Link connection or faulty IO-Link device
Quick, red flashing Incorrect IO-Link device or incorrect configuration
Red IO-Link short-circuit on Pin 4

www.balluff.com 40
10 Appendix

10.1. Type Code

BNI IOL-302-002-K006

Balluff Network Interface

IO-Link interface
Functions
302 = 16 inputs/outputs

Variants
002 = with IO-Link 1.1 extension port

Mechanical configuration
K006 = plastic housing, bus connection and
power supply: 1x M12x1, external thread,
I/O ports: 8 x M12x1, internal thread

10.2. Ordering Type code Ordering code


Information BNI IOL-302-002-K006 BNI007Z

www.balluff.com 41
www.balluff.com

No. 919408 E  Edition L14  Subject to modification

Balluff GmbH