Download as pdf or txt
Download as pdf or txt
You are on page 1of 285

User Manual

Augermatic
BP/FLUXX/BP2/MP/FXB/
MalePan/Vista

Code No. 99-97-7218


Edition: 01/2018 GB
Overview of changes / updates in the manual Page 1

Overview of changes / updates in the manual

Product
Type of information
change / / Editor’s
Chapter name update initials Issue date Page

3.10.3 ”Feed quantities Feed values updated, SSa 01/2018 41


in the pans” notes inserted

SSa
4.5.1 ”Sensor DOL 26” Chapter inserted 03/2017
01-0058

SSa
12.1 ”Sensor DOL 26” Chapter inserted 03/2017 228
01-0003

View and assembly with


8.5 ”Hopper” SSa 03/2017
extension inserted

SSa
Chapter inserted 09/2016
1671

Complete revision and RSi 04/2014


addition

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Table of contents Page I

1 Basic instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.1 EC declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Purpose of the BD manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Explanation of the symbols and structure of these instructions . . . . . . . . . 3
1.4.1 Structure of the safety instructions in this manual . . . . . . . . . . . . . . . . . . . . . . . 3
1.4.2 Structure of the general instructions in the manual . . . . . . . . . . . . . . . . . . . . . . 3
1.4.3 Special safety symbols in the manual and on the system . . . . . . . . . . . . . . . . . 4
1.5 Necessary qualifications of the persons working with the system. . . . . . . . 5
1.5.1 Employing external personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5.2 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5.3 Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.6 Obligations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.7 Warranty and liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.8 First aid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.9 Transport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.10 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.11 Pollution abatement regulations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.12 Waste disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.13 Notes for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.14 Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10


2.1 Instructions on accident prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.3 Personal safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.4 Personal protective equipment and measures . . . . . . . . . . . . . . . . . . . . . . . 12
2.5 Use of electrical appliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.6 Special safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6.1 Danger zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6.2 Entire system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.7 Individual parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.7.1 Auger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.7.2 Electrical components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.8 Safety contrivances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.9 Dangers resulting from non-compliance with the safety instructions . . . . 17
2.10 Safety component parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.11 Safety symbols at this system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

3 System description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21


3.1 Designated use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.2 Avoidance of foreseeable misuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page II Table of contents

3.3 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23


3.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
3.4.1 Technical data of the conveying system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
3.4.1.1 Available drive units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
3.4.2 Dimensions of feed pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
3.4.2.1 BigPan 330 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
3.4.2.2 FLUXX 330 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
3.4.2.3 FLUXX 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
3.4.2.4 BigPan 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
3.4.2.5 MultiPan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
3.4.2.6 FLUXX Breeder 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
3.4.2.7 MalePan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
3.4.2.8 Vista 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
3.5 Notes for layout and calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
3.5.1 BigPan 330 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
3.5.1.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
3.5.1.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .37
3.5.1.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
3.5.2 FLUXX 330 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
3.5.2.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
3.5.2.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .40
3.5.2.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
3.5.3 FLUXX 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
3.5.3.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
3.5.3.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .43
3.5.3.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
3.5.4 BigPan 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
3.5.4.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
3.5.4.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .46
3.5.4.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
3.5.5 MultiPan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
3.5.5.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
3.5.5.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .47
3.5.5.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
3.5.6 FLUXX Breeder 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
3.5.6.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
3.5.6.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .49
3.5.6.3 Feed quantities in the pans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
3.5.6.4 Dimensions of eating window at FLUXX breeder 360 rearing - production . . . . . . .50
3.5.6.5 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
3.5.7 MalePan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
3.5.7.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
3.5.7.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . .52
3.5.7.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
3.5.8 Vista 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
3.5.8.1 Area of use of feed pan and control pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Table of contents Page III

3.5.8.2 Determine complete lifting capacity for suspended feed lines . . . . . . . . . . . . . . . . 54


3.5.8.3 Recommended numbers of birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
3.5.9 Feeder 30 ltr Empa 2 (20-00-3930) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
3.5.10 Feeder 30ltr Empa 3 (20-00-3940) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
3.5.11 Feeder 30ltr Empa 4 (20-00-3950) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
3.5.12 Feeder 12 ltr Picorett (11-31-3080) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

4 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60


4.1 Important information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
4.2 Management recommendations for the housing and production . . . . . . . . 61
4.2.1 Preparations for the moving-in procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
4.2.1.1 Airing / ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
4.2.1.2 Heating / heat requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4.2.1.3 Feed supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4.2.1.4 Feeding system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4.2.1.5 Water supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.2.2 Place birds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4.2.3 Daily tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
4.2.3.1 House temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
4.2.3.2 Feeding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
4.2.4 Preparation of the moving-out procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.2.4.1 Climate before and after moving the birds out . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.2.4.2 Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.2.4.3 Shutting off the feed supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.2.5 After the moving-out procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.3 The feed pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.3.1 General features of the feed pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.3.2 BigPan 330 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.3.2.1 Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.3.2.2 Adjusting the feed level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
4.3.3 FLUXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
4.3.3.1 Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
4.3.3.2 Adjusting the feed level [FLUXX 330]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
4.3.3.3 Adjusting the feed level [FLUXX 360]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
4.3.4 BigPan 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
4.3.4.1 Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
4.3.4.2 Adjusting the feed level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
4.3.5 MultiPan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.3.5.1 Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
4.3.5.2 Adjusting the feed level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
4.3.6 FLUXX Breeder 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.3.6.1 Features: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4.3.6.2 Minimum sensor at lower part for feed hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
4.3.6.3 Adjusting the feed level [FLUXX Breeder 360 broiler breeder rearing] . . . . . . . . . 92
4.3.6.4 Possibilities for adjustment
[FLUXX breeder 360 broiler breeder rearing & production] . . . . . . . . . . . . . . . . . . 93

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page IV Table of contents

4.3.7 MalePan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97


4.3.7.1 Features:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
4.3.7.2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
4.3.7.3 MalePan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
4.3.7.4 MalePan Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101
4.3.7.5 Adjusting the feed level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
4.3.8 Vista 360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
4.3.8.1 Features:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
4.3.8.2 Adjusting the feed level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
4.3.9 Automatic flooding mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
4.4 Cable winch 350 kg GS for wall mounting incl. hand crank (99-50-3099) . .107
4.4.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
4.4.2 Selecting and fastening the cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
4.4.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
4.5 Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
4.5.1 Sensor DOL 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
4.5.1.1 Information concerning the sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
4.5.1.2 Electrical connection of DOL 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110
4.5.1.3 Technical data DOL 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
4.5.1.4 Functioning of the sensor DOL 26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
4.5.1.5 Setting the time delay and sensitivity at the sensor DOL 26 . . . . . . . . . . . . . . . . .112
4.5.2 Sensor DOL 44RG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
4.5.2.1 Information concerning the sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
4.5.2.2 Electrical connection of the DOL 44RG sensor . . . . . . . . . . . . . . . . . . . . . . . . . . .114
4.5.2.3 Technical data DOL 44RG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
4.5.2.4 Functioning of the sensor DOL 44RG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
4.5.2.5 Setting the time delay and sensitivity at the sensor DOL 44RG . . . . . . . . . . . . . . .117
4.6 Dial-type crane scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118

5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
5.1 Drive units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
5.1.1 Maintenance of the drive unit AM6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
5.1.2 Oil level control AM5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
5.2 Auger HD AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
5.2.1 Fastening of auger at the drive unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
5.2.2 Replace bearing at the tension shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
5.2.3 Repair auger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
5.2.4 Weld the auger HD AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
5.3 Replace conveying tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
5.3.1 Fixing the feed pans to the feed tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
5.3.2 Join the conveying tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137
5.3.3 Shorten the feed line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
5.3.4 Position of the control pan at the end tube . . . . . . . . . . . . . . . . . . . . . . . . . . .139
5.4 Cable winch 350 kg GS for wall mounting incl. hand crank (99-50-3099) . .140

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Table of contents Page V

6 Hygiene, health and safety, cleaning and disinfection. . . . . . . . . . . .142


6.1 Hygiene measures for maintaining a high hygiene level . . . . . . . . . . . . . . 142
6.2 Staff health and safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
6.3 Cleaning and disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
6.3.1 Comparison between wet and dry cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . 145
6.3.2 Service life of equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
6.3.3 Carrying out cleaning and disinfection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
6.3.3.1 Basic procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
6.3.3.2 Before cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
6.3.3.3 Primary cleaning, combating of rodents and applying insecticides . . . . . . . . . . . 148
6.3.3.4 Soaking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
6.3.3.5 Wet cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
6.3.3.6 Rinsing and drying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
6.3.3.7 Disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
6.3.3.8 Drying after a complete and successful wet disinfection procedure . . . . . . . . . . . 153

7 Troubles and their remedies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154


7.1 Hooked bolt M 6x35 broken. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
7.2 Warm place in the tube or hole picked in the tube . . . . . . . . . . . . . . . . . . . 154
7.3 The entire feed line does not start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
7.4 Protective motor switch regularly switches off the motor . . . . . . . . . . . . . 155
7.5 Auger operates irregularly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
7.6 Bearing of tension shaft is stuck or damaged. . . . . . . . . . . . . . . . . . . . . . . 156
7.7 Tube kink in the tube outlet holes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
7.8 Augermatic does not switch off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
7.9 Auger causes an excessive noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157

8 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158


8.1 Conveying tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
8.1.1 Tube 45x1.25-3050 2-4 hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
8.1.2 Tube 45x1,25x3050 MalePan (for MalePan and FLUXX Breeder 360). . . . . 160
8.1.3 End tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
8.2 Feed pans and control pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
8.2.1 Big Pan 330 single components [feed pans] . . . . . . . . . . . . . . . . . . . . . . . . . 162
8.2.2 Big Pan 330 single components [control pans] . . . . . . . . . . . . . . . . . . . . . . . 166
8.2.3 FLUXX 330 single components [feed pans] . . . . . . . . . . . . . . . . . . . . . . . . . 170
8.2.4 FLUXX 330 Single components [control pans] . . . . . . . . . . . . . . . . . . . . . . . 182
8.2.5 FLUXX 360 Single components [feed pans] . . . . . . . . . . . . . . . . . . . . . . . . . 190
8.2.6 FLUXX 360 Single components [control pans] . . . . . . . . . . . . . . . . . . . . . . . 198
8.2.7 BigPan 2 Single components [feed pans] . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
8.2.8 BigPan 2 Single components [control pans] . . . . . . . . . . . . . . . . . . . . . . . . . 210
8.2.9 MultiPan Single components [feed pans] . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
8.2.10 MultiPan Single components [control pans]. . . . . . . . . . . . . . . . . . . . . . . . . . 216

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page VI Table of contents

8.2.11 FLUXX Breeder 360 Single components [feed pans] . . . . . . . . . . . . . . . . . . .218


8.2.12 FLUXX Breeder 360 Single components [control pans] . . . . . . . . . . . . . . . . .220
8.2.13 MalePan Single components [feed pans] . . . . . . . . . . . . . . . . . . . . . . . . . . . .222
8.2.14 MalePan Single components [control pans] . . . . . . . . . . . . . . . . . . . . . . . . . .224
8.2.15 Vista 360 Single components [feed pans]. . . . . . . . . . . . . . . . . . . . . . . . . . . .228
8.2.16 Vista 360 Single components [control pans] . . . . . . . . . . . . . . . . . . . . . . . . . .229
8.3 Drive unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230
8.3.1 Drive unit AM6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230
8.3.2 Drive unit AM5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
8.3.3 AM4 drive unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236
8.3.4 AM3 drive unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238
8.4 Anti-roost unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240
8.4.1 Anti-roost wire for drive AM6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240
8.4.2 Anti-roost device for AM5 drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241
8.4.3 Anti-roost device for AM4 drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242
8.4.4 Anti-roost wire for drive AM3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243
8.5 Hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
8.5.1 Lower part for feed hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250
8.5.2 Tension shaft complete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251
8.6 Cable winch 350 kg GS for wall mounting incl. hand crank (99-50-3099) . .252
8.7 Feeders [single parts] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
8.7.1 Feeder 30 ltr Empa 2 (20-00-3930) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256
8.7.2 Feeder 30ltr Empa 3 (20-00-3940) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257
8.7.3 Feeder 30ltr Empa 4 (20-00-3950) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258
8.7.4 Feeder 12 ltr Picorett (11-31-3080). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259

9 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260

1 Checklist key points summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Basic instructions Page 1

1 Basic instructions

!
Important:
Please take care of these documents and keep them close to the system
at all times for quick reference.
All persons operating, maintaining and cleaning this system have to be
familiar with the contents of these instructions.
Observe these security instructions whenever any work is carried out on
this system!
Manuals can be reordered from Big Dutchman when necessary.

One of the following information is required to reorder a manual:


• the 8-digit code number of your language version [99-97-xxxx] as stated on your
manual's cover;
• the complete title of the manual including information on the type of instruction;
• if stated, the 8-digit universal code number [99-94-xxxx] including information on
the required language version.

1.1 EC declaration of conformity

We hereby declare that the system described in this manual corresponds to the
relevant health and safety requirements according to the EC directive because of its
design and construction as introduced to the market by us.
The declaration of conformity can be found at the beginning of the manual.

1.2 Purpose of the BD manuals

Depending on the intended use, Big Dutchman provides the following documentation:
1. Assembly manual
2. User manual
3. Operation manual (assembly and use of the system)
4. Spare parts lists
5. "Local add-on manuals": (for products which differ from those of the original manual
in specific countries).
The type of instruction of your manual can be found on the cover above the title.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 2 Basic instructions

1.3 Basics

The Big Dutchman system has been built with state-of-the-art technology and fulfils
the recognized technical safety requirements. It is safe to operate. However, danger to
the life and limb of third parties or impairments to the system or other property can
occur if it is used in an incorrect manner.
The system may only be installed, used, serviced and repaired under the following
conditions:
• in accordance with its designated use
• in an excellent state from the safety and technical point of view
• by trained, safety-conscious personnel familiar with the hazards associated with
the machine's use.
In the event of special problems which are not described in detail in this manual, we
recommend to contact us for your own safety.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Basic instructions Page 3

1.4 Explanation of the symbols and structure of these instructions

1.4.1 Structure of the safety instructions in this manual

Basic structure:

Pictograph Type of danger


Possible consequence(s) of non-compliance
Signal word • Measure(s) against the danger

Meaning of the signal words:

Pictograph Signal Meaning Consequences of non-


word compliance
Possible personal injuries:
DANGER directly dangerous Will lead to death or severe
possible safety situation injuries.
symbols: WARNING possibly May lead to death or severe
dangerous situation injuries.
see chapter
CAUTION possibly May lead to minor injuries.
1.4.3
dangerous situation
Possible damage to property:
CAUTION May lead to damage to property

1.4.2 Structure of the general instructions in the manual

! IMPORTANT!
This symbol indicates important information. There is no risk of personal
injuries or damage to property.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 4 Basic instructions

1.4.3 Special safety symbols in the manual and on the system

These safety symbols (pictographs) illustrate remaining dangers when handling the
system. They are used in the safety instructions of this manual (also refer to chapter
1.4.1) and on the system.

Warning: general danger

Warning: dangerous electric tension

Warning: laser beam

Safety symbols and instructions on the system must always be


easily visible and undamaged.
• If they are soiled by dust, manure, feed remains, oil or grease,
CAUTION
clean them with a water-detergent mixture.
• Damaged, lost, or unreadable safety symbols have to be
replaced immediately.
• If a safety symbol or instruction is fixed to a part to be replaced,
ensure that it will be fixed to the new part as well.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Basic instructions Page 5

1.5 Necessary qualifications of the persons working with the system

1.5.1 Employing external personnel

! IMPORTANT:
The supervisor is responsible for the safety of external personnel.

Mounting works are frequently carried out by external personnel not familiar with the
circumstances specific for the system and the inherent dangers.
You as operator are to survey the personnel and to define responsibilities and powers.
Inform these people in detail on the dangers of their area of work. Check their method
of working and intervene as soon as possible.

1.5.2 Assembly

Assembly of the system can be carried out by the farmer himself or by a person
authorized by him. We assume that the operator or the authorized person either have
received technical training or have the necessary knowledge or practical experience
that are necessary for a proper assembly of the system.

1.5.3 Electrical installation

Work on the electric components may only be carried out by technically skilled
personnel and according to German Industry Standards, VDE regulations, safety
instructions and electro-technical regulations of the power supply industry (EVU) and
the applicable national regulations.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 6 Basic instructions

1.6 Obligations

Closely adhere to the instructions in this manual.


A basic condition for safe operation and trouble-free handling of this system is the
knowledge of the basic safety instructions and regulations.
This manual, particularly the safety instructions, must be observed by all persons
working on this system. Moreover, the regulations and instructions for the prevention
of accidents valid at the respective place of use have to be observed.
The manufacturer is not responsible for any damage to the system resulting from
changes not authorized by Big Dutchman.

1.7 Warranty and liability

Warranty and liability claims regarding personal injury or property damage are
excluded if they result from one or several of the following causes:
• inappropriate assembling of the system;
• non-compliance with the instructions in this manual regarding transport, storage
and assembly;
• unauthorized modifications to the system;
• disasters caused by foreign matter or force majeure.

1.8 First aid

In the case of an accident, a first-aid kit must always be available at the place of work,
unless otherwise specified. Material taken out and used is to be replaced immediately.
If you need help, describe the accident as follows:
• where it happened
• what happened
• the number of persons injured
• what type of injury
• who is reporting the accident.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Basic instructions Page 7

1.9 Transport

Due to the high number of possible building units and parts, we can only supply general
information in this manual. This information should be sufficient for experienced
technicians and transport experts. If you have questions, please contact Big
Dutchman.
The system is supplied in pre-assembled building units and packaging units. They have
to be secured adequately against shifting and tilting during transport. The transport has
to be carried out by experts.
The building and packaging units are transported to the construction site with
appropriate means of transport. To avoid any possible damage, make sure that the
units are loaded and unloaded carefully. If the goods are transported by hand, please
keep in mind the reasonable human lifting and carrying abilities.
See that the transport is carried out safely. Avoid bumps and impacts and see to a
secure standing at every stage of the transport.
The scope of the delivery is listed in the shipping documents. Please check for
completeness upon receipt. Possible transport damage and / or missing parts have to
be reported immediately in writing.

1.10 Storage

Thermal expansion causes by temperature changes


• Store the building parts where they will be needed so that their
temperature can adjust to the environment.
CAUTION
The storage area should be dry and roofed. If this is not possible, the parts should be
covered with PE-foil and stored with enough ground clearance. Make sure that, when
stored, the parts are protected against dust and moisture.

Storage of electrical parts


• Store all electrical parts in a dry and closed space.

CAUTION
Open-air storage is acceptable only for a short time. If stored outside for a longer time,
the parts have to be protected against harmful environmental influences. They also
have to be protected against mechanical damage.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 8 Basic instructions

1.11 Pollution abatement regulations

All works on and with the installation have to be carried out in compliance with the legal
requirements concerning waste prevention and proper recycling / disposal of waste.
Water pollutants like lubricating grease and oils as well as solvent-containing cleaning
solutions may not pollute the soil or reach the canalisation! These materials have to be
kept, transported, collected and disposed of in appropriate containers!

1.12 Waste disposal

After completing the assembly, dispose of the packing material and all remains which
cannot be used further according to the legal provisions for recycling.

1.13 Notes for use

In the interest of further development, we reserve the right to modify design and
technical data of this installation.
No claims can therefore be derived from any information, illustration or drawing and
description contained herein. Errors and omissions excepted!
Inform yourself about adjusting, operating and maintenance requirements before
putting the system into operation.
Apart from the safety information in this manual and the obligatory accident prevention
regulations applicable in the user's country, please heed the accepted technical rules
(safe and expert working in accordance with UVV, VBG, VDE etc.).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Basic instructions Page 9

1.14 Copyright

This manual is copyrighted. The information and drawings included in this manual shall
not be copied without the manufacturer's consent, nor shall they be misused or be
disclosed to third parties.
The contents of this manual can be altered without prior notice.
If you find mistakes or unclear information in this manual, please do not hesitate to let
us know.
All trademarks mentioned or shown in the text are trademarks of their respective
owners and deemed patented.

 copyright 201 by Big Dutchman

For further information please contact:


Big Dutchman International GmbH, P.O. Box 1163, D-49360 Vechta, Germany, 
Phone +49 (0)4447/801-0, Fax +49 (0)4447/801-237
E-Mail: big@bigdutchman.de, Internet: www.bigdutchman.de

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 10 Safety instructions

2 Safety instructions

2.1 Instructions on accident prevention

Before operating, cleaning, maintaining or disassembling this system, the operator or


person authorized by him is obliged to instruct any person carrying out any of these
works on
• the remaining dangers when carrying out these tasks
• the applicable rules and regulations regarding accident prevention and to ensure
they are complied with!
The basis for these are:
• the installation's technical documentation, specifically the included safety
instructions,
• the applicable safety and health regulations applicable at the place of work.

2.2 General safety instructions

Risk of injury
Children in the area of the system are at risk of injury as they can
often not be supervised sufficiently and are not able to
recognize hazards.
WARNING • Ensure that children do not use the system as a playground and
are not left unsupervised in the vicinity of the system. Explain
remaining dangers fully to the children.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Safety instructions Page 11

The respective safety precautions and other generally accepted regulations regarding
safety and operational health have to be observed. 
Please check safety and function control devices to ensure safe and accurate
operation
• before putting the system into operation again
• in adequate intervals (confer maintenance intervals)
• after modifications or repairs.
Check the proper functioning of the system after any kind of repair works. You may only
put the device into operation when all protective system have been put into place again.
Also observe the regulations of local water distribution and power supply companies.

2.3 Personal safety instructions

These safety instructions are intended to make you familiar with important information
on the handling of the system. They are important for your safety and for the safety of
the system.
The farm staff has to familiarize itself with the function and arrangement of the safety
devices, in particular of the emergency stop button.
The farm staff has to regularly participate in health and safety briefings (according to
the provisions e.g. by trade associations).
Maintenance works may only be carried out by specially trained personnel.

Risk of injury
Lack of knowledge about the structural design of the system can
lead to injury.
• Make yourself familiar with the design and construction of the
WARNING system under sufficient lighting!
• Inform yourself as responsible person for the system and your
employees about the remaining dangers in connection with this
system!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 12 Safety instructions

2.4 Personal protective equipment and measures

Risk of injury
The following instructions apply to all works carried out on the
system.
• Wear close-fitting protective clothing and protective
WARNING footwear.
• Use protective gloves where there is a risk of hand injuries and
safety goggles where there is a risk of eye injuries.
• Do not wear any rings, necklaces, watches, scarves, ties or
other items which could get caught in parts of the system.
• Make sure that long hair is always tied back. Hair can get
caught in powered or rotating working units or parts of the
installation, resulting in severe injuries.
• When working underneath the installation always wear a hard
hat!

2.5 Use of electrical appliances

You as the person responsible for the system or his agent have to ensure that the
system with its electrical appliances is operated and maintained according to the local
electro-technical regulations.

Risk of injury and danger to life


Dangerous electric tension may be bare in the case of open
control units and may cause severe injuries or lead to death!
• Be aware of the danger and keep workers of other professions
away from the danger zone.
• Installations and works on electric components/building units may
only be carried out by qualified persons according to electro-
technical regulations (e.g. EN 60204, DIN VDE 0100/0113/0160).
WARNING
• Immediately switch off the system in the event of malfunctions of the power supply
units. Check that the electrical equipment is not alive.
• Check the electrical wiring and cables for recognisable damage before putting the
system into operation again. Replace damaged wiring and cables before taking the
system into operation.
Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Safety instructions Page 13

Danger of short circuits


Never repair or shut defective fuses.
• Defective fuses should be replaced by new ones immediately.

WARNING
• Never cover an electrical motor. This can cause high temperatures resulting in fires
and the destruction of the equipment.
• Always keep the switch cabinet and all terminal and connection boxes closed.
• Damaged or broken plugs should be immediately replaced by an electrician.
• Do not pull the plug from the socket at the flexible cable.
• For the respective connections please see the enclosed connecting plan of the
system parts delivered.

2.6 Special safety instructions

2.6.1 Danger zone

The individual zones of the Big Dutchmansystem are constructed differently.There are
several ejecting, rotating or sliding parts that might be a risk if you are not familiar with
their type of construction.

Risk of injury
Lack of knowledge regarding the system's type of construction
increases the risk of injury.
• Never reach into the running system. First stop the system and
WARNING secure it against an inadvertent restart.
• Assure yourself before reaching into the system that the main
switch is in the OFF position and cannot be put in the ON position
without your knowledge.
The system has been equipped with all mechanisms that guarantee a safe operation.
In places where the danger zone could not be safeguarded totally, in consideration of
the operational reliability, safety signs have been placed. They indicate remaining
technical dangers when handling the system and give information on how to avoid
these dangers.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 14 Safety instructions

Safety symbols and instructions on the system must always be


easily visible and undamaged.
• If they are soiled by dust, manure, feed remains, oil or grease,
CAUTION
clean them with a water-detergent mixture.
• Damaged, lost, or unreadable safety symbols have to be
replaced immediately.
• If a safety symbol or instruction is fixed to a part to be replaced,
ensure that it will be fixed to the new part as well.

2.6.2 Entire system

Only use suitable tools and observe the local accident prevention regulations.
Ensure that the system is switched off before performing any repair or maintenance
work or cleaning, or rectifying any functional defects. Disconnect the system from the
power supply and secure it against being switched back on.
Secure the system by placing a “Do not use” sign on the master switch and include a
notice about maintenance being performed, if required.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Safety instructions Page 15

Risk of injury
Parts lying about on the system and in its vicinity can cause
persons to stumble and/or fall and thus risk injuring themselves
by contact with system components.
WARNING Lack of knowledge about the structural design of the system can
lead to injury.
Party lying about in or on the components can lead to serious
damage of the system.
• Never deposit objects (e.g. spare parts, replaced parts, tools,
cleaning tools etc.) in the accessible areas of the system or in the
surrounding areas have having carried out works on the system!
• Make yourself familiar with the design and construction of the
system under sufficient lighting! If this is not possible, inform
yourself about any remaining dangers in connection with this
system!
• Before restarting the system, assure yourself that all loose or
replaced parts have been removed from the system components!
• The device may only be put into operation after all protective
systems have been put into place again and are functioning.

2.7 Individual parts

2.7.1 Auger

Risk of injury
Rotating parts of the feeding system can lead to injuries.
• The power supply must always be disconnected before working
on the feeding system since this can start unexpectedly if the
WARNING system is operated via an automatic control system.
• Never grasp into the auger running in the feed hopper.
• Never grasp into the auger rotating in the tubes.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 16 Safety instructions

2.7.2 Electrical components

Risk of electric shocks and short circuits


Live parts may be bare while different kinds of work are carried
out. Touching live parts might lead to injuries caused by electric
shock and short circuits.

WARNING • Before performing any repair or maintenance work, turn the main
switch to "OFF" and display a sign warning that repair or
maintenance work is in progress!
• Never touch bare electrical components. Equipment with bare
electrical components must not be used by the farm staff.

2.8 Safety contrivances

Risk of injury and danger to life


Defective or disassembled safety contrivances can lead to
severe injuries or to death!
• It is strictly forbidden to remove or put out of operation any safety
contrivance.
• Should the safety contrivances be damaged, the system has to
be put out of operation immediately. The main switch has to be
locked in zero position and damages have to be eliminated.
WARNING • Make sure that all safety contrivances are properly mounted and
functioning after all works on the system and before putting the
system into operation again

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Safety instructions Page 17

2.9 Dangers resulting from non-compliance with the safety


instructions

Non-observance of these instructions can cause severe danger for life and health of
people or can lead to material or environmental damages and to the forfeiture of any
claim for damages. To be precise, the non-observance of these instructions can lead to:
• Failure of vital functions of the installation
• Failure of prescribed maintenance methods
• Dangers for people owing to electrical and mechanical influences.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 18 Safety instructions

2.10 Safety component parts

!
The system described in this manual may only be operated if the listed
safety component parts have been mounted and installed correctly and
have been checked for correct functioning!
If safety component parts are missing or defective, the original part must
be ordered from Big Dutchman and replaced immediately!

The Augermatic feed line comprises the following safety components:

Pos. Code no. Description


1 11-31-1315 Wire mesh guard cpl for lower part of hopper BP/AM
consisting of:
11-31-1314 Wire mesh guard for lower part of hopper BP/AM
99-10-1602 Mushroom head square neck bolt M 6x 16 DIN 603 4.6 galv
99-10-3953 Washer 6.4x30x1.5 galv
99-20-1043 Self-locking counter nut M 6 galv DIN985-6
2 83-07-9239 Wire mesh guard for bracket of drive AM6
3 83-09-2274 Cap rubber for Augermatic AM tension shaft

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Safety instructions Page 19

2.11 Safety symbols at this system

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 20 Safety instructions

00-00-1119

00-00-1118 00-00-1186

Pos. Code no. Description


1 00-00-1119 Sticker D/GB/F: End pipe for control pan
2 00-00-1188 Pictograph: Risk of injury / hopper
3 00-00-1186 Pictograph: Before maintenance work main switch "OFF"

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 21

3 System description
The Big DutchmanAugermatic with the different feed pans is a special pan feeding
system which meets the requirements of the day-old chicks as well as those of full-
grown poultry as broilers, layers, turkeys or ducks.
A restrictive feeding of e.g. broiler breeders is possible as well.
These birds are genetically predisposed to realise enormous growth, however, the
objective of production at this level is to produce hatching eggs so that special feeding
requirements must be fulfilled.

Passage height at a lifted system

All dimensions in mm
The dimension 1500 is an approximate dimension and depends on the hook length
X = passage height (ceiling height - 1500mm)
Y = ceiling height

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 22 System description

3.1 Designated use

The Big Dutchman Augermatic may only be used for the transport of pourable animal
feed with a grain size of 4 mm max.
The Big Dutchman system may only be used according to its designated use.
Every other use is considered non-designated. The manufacturer does not accept
liability for damages resulting from other uses, the user alone has to bear the risk. The
designated use also includes the exact following of the operation, maintenance and
repair conditions as prescribed by the manufacturer.

3.2 Avoidance of foreseeable misuse

The following uses of the Big Dutchman system are not permitted and qualify as
misuse:
• Filling foreign objects in the conveying auger at the feed hopper and drive
• Filling the feed screw with feed, which has a too low dry substance content (< 84%)
or a too high fat content and which is not sufficiently free-flowing
• Operation of the system with fully functional anti-perching wire
• Using improper detergents and disinfectants.
• Too long residence time of detergents and disinfectants.
A non-designated use will lead to a liability exclusion by Big Dutchman.
The operator of the system exclusively bears the risk resulting from misuse!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 23

3.3 Overview

Figure 3-1: Feed line with feed


hopper 1-line

Pos. Description
1 Feed hopper
2 Conveying pipe with auger
3 Feed pan
4 Control pan with sensor
5 Drive AM
6 Anti-roost wire
7 Suspension
8 Extension for feed hopper

Figure 3-2: Feed line with feed


hopper 2-lines central

Pos. Description
1 Feed hopper
2 Conveying pipe with auger
3 Feed pan
4 Control pan with sensor
5 Drive AM
6 Anti-roost wire
7 Suspension
8 Extension for feed hopper

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 24 System description

3.4 Technical data

3.4.1 Technical data of the conveying system

Hopper with feed hopper: Contents approx. 115 l / 75 kg


Extension for feed hopper: Content approx. 38 l / 25 kg
0.55/ 0.75 kW, 230/400V 50 Hz, 3 phases, 320
Drive unit with gear motor: rpm (rotations per minute)
(=> 3.4.1.1 ”Available drive units”)
Conveying capacity: approx. 450 kg/h (kilogram per hour)
Pellet size: up to 4 mm
Material feed pans: Polypropylene, to recycle
During feeding, the Big Dutchman Augermatic systems creates a sound level < 70
dB (A).

3.4.1.1 Available drive units

For BP / FLUXX / BP2 / MP / MalePan and Vista:

Maximum Operating
Code no. Description
line lengths (m) voltage (V)
Drive 0.55KW 230/400V 50Hz AM6 wo/
11-31-5020 145 400
sensor with switch box
Drive 0.55kW 220/380V 60Hz AM6 wo/
11-31-5021 145 380
sensor w/switch box
Drive 0.55kW 200V 3PH 50Hz AM6 wo/
11-31-5022 145 200
sensor w/switch box
Drive 0.55kW 200V 3PH 60Hz AM6 wo/
11-31-5023 145 200
sensor w/switch box
Drive 0.55kW 230V 1PH 50Hz AM6 wo/
11-31-5024 145 230
sensor w/switch box
Drive 0.55kW 230/400V 50Hz AM6 wo/
37-96-9528 145 400
sensor w/switch box AMX
Drive 0.55kW 220/380V 60Hz AM6 wo/
37-96-9531 145 380
sensor w/switch box AMX

For MalePan:

Maximum Operating
Code no. Description
line length (m) voltage (V)
Drive 0.75kW 230V 1PH 50Hz S3 AM6
11-03-3705 75 230
Rapid-Rooster wo/sensor w/switch box
Drive 0.55kW 230/400V 50Hz AM6 Rapid-
11-03-3753 75 400
Rooster wo/sensor w/switch box

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 25

3.4.2 Dimensions of feed pans

3.4.2.1 BigPan 330

11-31-3501 Feed pan cpl BP330 wo/shut- 11-31-3530 Feed pan cpl BP330 with
off shut-off

11-31-3701 Feed pan cpl BP330-Plus wo/ 11-31-3730 Feed pan cpl BP330-Plus with
shut-off shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 26 System description

3.4.2.2 FLUXX 330

The height dimension of these feed pans is variable. The height dimension
indicated here is the maximum height.

11-31-4773 Feed pan cpl FLUXX 330-5 11-31-1522 Feed pan cpl FLUXX 330-5
without shut-off with shut-off

11-31-4774 Feed pan cpl FLUXX 330-5 11-31-1524 Feed pan cpl FLUXX 330-5
plus without shut-off plus with shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 27

11-31-4742 Feed pan cpl FLUXX 330-5 11-31-4740 Feed pan cpl FLUXX 330-5
w/AMX-dish without shut-off with AMX-dish with shut-off

11-31-4771 Feed pan cpl FLUXX 330-14 11-31-1521 Feed pan cpl FLUXX 330-14
without shut-off with shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 28 System description

11-31-4772 Feed pan cpl FLUXX 330-14 11-31-1523 Feed pan cpl FLUXX 330-14
plus without shut-off plus with shut-off

11-31-4747 Feed pan cpl FLUXX 330-14 11-31-4745 Feed pan cpl FLUXX 330-14
w/AMX-dish without shut-off w/AMX-dish with shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 29

3.4.2.3 FLUXX 360

The height dimension of these feed pans is variable. The height dimension
indicated here is the maximum height.

11-31-4680 Feed pan cpl FLUXX 360-8 11-31-4685 Feed pan cpl FLUXX 360-8
without shut-off with shut-off

11-31-4780 Feed pan cpl FLUXX 360-8 11-31-4785 Feed pan cpl FLUXX 360-8
plus without shut-off plus with shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 30 System description

11-31-4670 Feed pan cpl FLUXX 360-16 11-31-4675 Feed pan cpl FLUXX 360-16
without shut-off with shut-off

11-31-4770 Feed pan cpl FLUXX 360-16 11-31-4775 Feed pan cpl FLUXX 360-16
plus without shut-off plus with shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 31

3.4.2.4 BigPan 2

The height dimension of these feed pans is variable. The height dimension
indicated here is the maximum height.

11-31-1532 Feed pan cpl BigPan 2 330-5 11-31-4931 Feed pan cpl BigPan 2 330-5
without shut-off w/shut-off

11-31-1534 Feed pan cpl BigPan 2 330-5 11-31-4921 Feed pan cpl BigPan 2 330-5
plus without shut-off plus w/shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 32 System description

11-31-1531 Feed pan cpl BigPan 2 330-14 11-31-4911 Feed pan cpl BigPan 2 330-14
without shut-off w/shut-off

11-31-1533 Feed pan cpl BigPan 2 330-14 11-31-4901 Feed pan cpl BigPan 2 330-14
plus without shut-off plus w/shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 33

3.4.2.5 MultiPan

11-31-3555 Feed pan cpl MP330 with 11-31-3555 Feed pan cpl MP330 with
shut-off and BP-dish shut-off and BP-dish
with feed saving collar (= option)

11-31-3565 Feed pan cpl MP330-plus with 11-31-3565 Feed pan cpl MP330-plus with
shut-off with RPM-dish shut-off with RPM-dish
with feed saving collar (= option)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 34 System description

3.4.2.6 FLUXX Breeder 360

The height dimension of these feed pans is variable. The height dimension
indicated here is the maximum height.

11-31-3815 Feed pan cpl FXB360 for tube 11-31-3810 Feed pan cpl FXB360 for tube
dia 45 BB-rearing dia 45 BB-rearing & product.

Height feed pan (mm)


(distance between floor and upper edge of the pan)
67.5 X = 67.5 - 85.8
Widths of eating window (mm)
not alterable 34 - 53
Heights of eating window (mm)
not alterable 55 - 73

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 35

3.4.2.7 MalePan

11-31-3585 Feed pan cpl MalePan with 11-31-3590 Feed pan cpl MalePan plus
shut-off and BP-dish with shut-off and RPM-dish

3.4.2.8 Vista 360

11-31-4860 Feed pan cpl Vista 360

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 36 System description

3.5 Notes for layout and calculation

3.5.1 BigPan 330

3.5.1.1 Area of use of feed pan and control pan

Preparatory and final fattening of turkeys*


Kind of feeding Weight range

Preparatory and final fattening of ducks*

(geese, pheasants, guinea fowls, etc.)*

11-31-3569 feed saving collar

11-31-3569 feed saving collar


Area of use

7.0 - 12kg, only with:


2 - 7kg, only with: 
Broiler production*
Turkey rearing*

Pullet rearing*
Duck rearing*

controlled
ad libitum

restricted
0 - 2.5kg
0 - 3.5kg
rationed
Layers*
Other

11-31- Feed pan complete. BigPan


    
3501 330 without shut-off
11-31- Feed pan cpl BP330 with shut-
    
3530 off
11-31- Feed pan cpl BP330-Plus wo/
      
3701 shut-off
11-31- Feed pan cpl BP330-Plus with
      
3730 shut-off

11-31- Control pan cpl BigPan 330


    
3552 including sensor DOL 26
11-31- Control pan cpl BigPan 330
      
3732 plus including sensor DOL
11-31- Control pan cpl BigPan 330
    
3553 including sensor DOL 44RG
11-31- Control pan cpl BigPan 330
   
3551 excluding sensor

* Observe weight ranges:  suitable

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 37

3.5.1.2 Determine complete lifting capacity for suspended feed lines

Basic unit tube 2-holes with feed pans + feed: 13.2 kg/pc
Basic unit tube 3-holes with feed pans + feed: 15.9 kg/pc
Basic unit tube 4-holes with feed pans + feed: 18.3 kg/pc
Feed hopper + feed: 90.0 kg/pc
Drive 20.0 kg/pc
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

3.5.1.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

for the ad-libitum feeding of broilers:


Range of weight: 0 - 3.5 kg

(125 : desired final weight kg/bird) + 20


Example calculation
for example:(125 : 1.25 kg/bird) + 20 = 120 birds/pan

up to 1.5 kg end weight = 100 birds


up to 2.0 kg end weight = 85 birds
Number of birds per pan: up to 2.5 kg end weight = 70 birds
up to 3.0 kg end weight = 66 birds
up to 3.5 kg end weight = 55 birds

for the feeding of pullets and layers:


Weight range 1.3 - 1.5 kg
Number of birds per pan: 45 - 60 pullets
Weight range: 1.8 - 2.2 kg
Number of birds per pan: 30 - 45 layers

for the rationed feeding of broilers:


Number of birds per pan: calculate approx. 25 - 30% less bird per pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 38 System description

3.5.2 FLUXX 330

3.5.2.1 Area of use of feed pan and control pan

Preparatory and final fattening of turkeys **


Kind of Weight

Preparatory and final fattening of ducks **


feeding range

(geese, pheasants, guinea fowls, etc.)*


Area of use

Broiler production *
Turkey rearing **

Duck rearing **

Pullet rearing*

controlled

restrictive
ad libitum

0 - 2.5kg

0 - 3.5kg
rationed
Layers*
Other
Feed pan cpl FLUXX
11-31-4771     
330-14 without shut-off
Feed pan cpl FLUXX
11-31-1521     
330-14 with shut-off
Feed pan cpl FLUXX
11-31-4772     
330-14 plus without shut-off
Feed pan cpl FLUXX
11-31-1523      
330-14 plus with shut-off
Feed pan cpl FLUXX 330-14
11-31-4747     
with AMX-dish without shut-off
Feed pan cpl FLUXX 330-
11-31-4745     
14 with AMX-dish with shut-off

11-31-4773 Feed pan cpl FLUXX 330-5 without shut-off     


11-31-1522 Feed pan cpl FLUXX 330-5 with shut-off     
Feed pan cpl FLUXX 330-5 plus without
11-31-4774          
shut-off
11-31-1524 Feed pan cpl FLUXX 330-5 plus with shut-off          
Feed pan cpl FLUXX 330-5
11-31-4742     
with AMX-dish without shut-off
Feed pan cpl FLUXX 330-5
11-31-4740     
with AMX-dish with shut-off

* Observe weight ranges:  suitable

* * up to 2.0 kg / with feed saving collar (11-31-3569) up to 12 kg

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 39

Preparatory and final fattening of turkeys **


Kind of Weight

Preparatory and final fattening of ducks **


feeding range

(geese, pheasants, guinea fowls, etc.)*


Area of use

Broiler production *
Turkey rearing **

Duck rearing **

Pullet rearing*

controlled

restrictive
ad libitum

0 - 2.5kg

0 - 3.5kg
rationed
Layers*
Other
Control pan FLUXX330-14 including sensor
11-31-4776      
DOL
Control pan FLUXX330-14 including sensor
11-31-4829      
DOL 44RG
Control pan FLUXX330-14 plus including
11-31-4777          
sensor DOL 26
Control pan FLUXX330-14 plus including
11-31-4839          
sensor DOL 44RG
Control pan cpl FLUXX330-14 with AMX
11-31-4746     
dish
Control pan FLUXX330-5 including sensor
11-31-4778     
DOL
Control pan FLUXX330-5 plus including
11-31-4781       
sensor DOL 26
11-31-4741 Control pan cpl FLUXX330-5 with AMX dish     

* Observe weight ranges:  suitable

* * up to 2.0 kg / with feed saving collar (11-31-3569) up to 12 kg

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 40 System description

3.5.2.2 Determine complete lifting capacity for suspended feed lines

With maximum feed filling:

Base unit tube 2 hole with feed pans + feed: 13.2 kg / pc


Base unit tube 3 hole with feed pans + feed: 15.5 kg / pc
Base unit tube 4 hole with feed pans + feed: 18.3 kg / pc
Feed hopper + feed: 90.0 kg / feed line
Drive 20.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 41

3.5.2.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

for the ad-libitum feeding of broilers:


Range of weight: 0 - 3.5 kg

(125 : desired final weight kg/bird) + 20


Example calculation
for example:(125 : 1.25 kg/bird) + 20 = 120 birds/pan

up to 1.5 kg end weight = 100 birds


up to 2.0 kg end weight = 85 birds
Number of birds per pan: up to 2.5 kg end weight = 70 birds
up to 3.0 kg end weight = 66 birds
up to 3.5 kg end weight = 55 birds

for the feeding of pullets and layers:


Weight range: 1.3 - 1.5 kg
Number of birds per pan: 45 - 60 pullets
Weight range: 1.8 - 2.2 kg
Number of birds per pan: 30 - 45 layers

for the rationed feeding of broilers:


Number of birds per pan: calculate approx. 25 - 30% less bird per pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 42 System description

3.5.3 FLUXX 360

3.5.3.1 Area of use of feed pan and control pan

Preparatory and final fattening of turkeys *


Weight
Kind of feeding

Preparatory and final fattening of ducks*

(geese, pheasants, guinea fowls, etc.)*


range

Area of use
Broiler production *
Turkey rearing **

Duck rearing **

Pullet rearing*

controlled

restrictive
ad libitum

0 - 2.5kg

0 - 3.5kg
rationed
Layers*
Other
11-31-4680 Feed pan cpl FLUXX 360-8 without shut-off       
11-31-4685 Feed pan cpl FLUXX 360-8 with shut-off       
Feed pan cpl FLUXX 360-8 plus without
11-31-4780        
shut-off
Feed pan cpl FLUXX 360-8 plus with shut-
11-31-4785        
off

Feed pan cpl FLUXX 360-16 without shut-


11-31-4670     
off
11-31-4675 Feed pan cpl FLUXX 360-16 with shut-off     
Feed pan cpl FLUXX 360-16 plus without
11-31-4770      
shut-off
Feed pan cpl FLUXX 360-16 plus with shut-
11-31-4775      
off

Control pan cpl. Fluxx360-16 without shut-


11-31-4679     
off
Control pan cpl. Fluxx360-16 plus without
11-31-4779      
shut-off
11-31-4689 Control pan cpl. Fluxx360-8 without shut-off       
Control pan cpl. Fluxx360-8 plus without
11-31-4789        
shut-off

* Observe weight ranges:  suitable

* * up to 2.0 kg

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 43

3.5.3.2 Determine complete lifting capacity for suspended feed lines

With maximum feed filling:

Basic unit tube 2 hole with feed pans + feed: 14.2 kg / pc


Basic unit tube 3 hole with feed pans + feed: 17.8 kg / pc
Basic unit tube 4 hole with feed pans + feed: 21.8 kg / pc
Feed hopper + feed: 90.0 kg / feed line
Drive 20.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

3.5.3.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

for the ad-libitum feeding of broilers:


Weight range: 0 - 3.5 kg

((125 : desired final weight kg/bird) + 20) x 1.12


Example calculation: for example:
((125 : 1.25 kg/bird) + 20) x 1.12 = 134 birds/pan

up to 1.5 kg final weight = 112 birds


up to 2.0 kg final weight = 95 birds
Number of birds per pan: up to 2.5 kg final weight = 78 birds
up to 3.0 kg final weight = 73 birds
up to 3.5 kg final weight = 61 birds

for the feeding of pullets and layers:


Weight range: 1.3 - 1.5 kg
Number of birds per pan: 50 - 67 pullets
Weight range: 1.8 - 2.2 kg
Number of birds per pan: 33 - 50 layers

for the rationed feeding of broilers:


number of birds per pan: calculate approx. 25 - 30% less bird per pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 44 System description

3.5.4 BigPan 2

3.5.4.1 Area of use of feed pan and control pan

Preparatory and final fattening of turkeys*


Kind of feeding Weight range

Preparatory and final fattening of ducks*

(geese, pheasants, guinea fowls, etc.)*

11-31-3569 feed saving collar

11-31-3569 feed saving collar


Area of use

7.0 - 12kg, only with:


2 - 7kg, only with: 
Broiler production*
Turkey rearing*

Pullet rearing*
Duck rearing*

controlled

restrictive
ad libitum

0 - 2.5kg
0 - 3.5kg
rationed
Layers*
Other
11-31- Feed pan cpl BigPan 2 330-5
    
1532 without shut-off
11-31- Feed pan cpl BigPan 2 330-5
    
4931 with shut-off
11-31- Feed pan cpl BigPan 2 330-5
     
1534 plus without shut-off
11-31- Feed pan cpl BigPan 2 330-5
     
4921 plus with shut-off

11-31- Feed pan cpl BigPan 2 330-14


    
1531 without shut-off
Feed pan cpl Gladiator dia 45
11-31-
manually with rearing pan,     
4911
without cone
11-31- Feed pan cpl BigPan 2 330-14
     
1533 plus without shut-off
11-31- Feed pan cpl BigPan 2 330-14
     
4901 plus with shut-off

11-31-
Control pan cpl. BigPan2 330-5     
4939
11-31- Control pan cpl. BigPan2 330-5
     
4929 plus

11-31- Control pan cpl. BigPan2 330-


    
4919 14
11-31- Control pan cpl. BigPan2 330-
     
4909 14 plus

* Observe weight ranges:  suitable

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 45

3.5.4.2 Determine complete lifting capacity for suspended feed lines

Basic unit tube 2 hole with feed pan + feed: 13.2 kg / pc


Basic unit tube 3 hole with feed pan + feed: 15.9 kg / pc
Basic unit tube 4 hole with feed pan + feed: 18.3 kg / pc
Feed hopper + feed: 90.0 kg / feed line
Drive 20.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 46 System description

3.5.4.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

for the ad-libitum feeding of broilers:


Range of weight: 0 - 3.5 kg

(125 : desired final weight kg/bird) + 20


Example calculation
for example:(125 : 1.25 kg/bird) + 20 = 120 birds/pan

up to 1.5 kg end weight = 100 birds


up to 2.0 kg end weight = 85 birds
Number of birds per pan: up to 2.5 kg end weight = 70 birds
up to 3.0 kg end weight = 66 birds
up to 3.5 kg end weight = 55 birds

for the feeding of pullets and layers:


Weight range: 1.3 - 1.5 kg
Number of birds per pan: 45 - 60 pullets
Weight range: 1.8 - 2.2 kg
Number of birds per pan: 30 - 45 layers

for the rationed feeding of broilers:


Number of birds per pan: calculate approx. 25 - 30% less bird per pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 47

3.5.5 MultiPan

3.5.5.1 Area of use of feed pan and control pan

Preparatory and end fattening of turkeys*


Kind of feeding Weight range

Preparatory and end fattening of ducks*

(geese, pheasants, guinea fowls, etc.)*

11-31-3569 feed saving collar

11-31-3569 feed saving collar


Area of use

7.0 - 12kg, only with: 


2 - 7kg, only with: 
Broiler production*
Turkey rearing*

Pullet rearing*
Duck rearing*

controlled

restrictive
ad libitum

0 - 2.5kg
0 - 3.5kg
rationed
Layers*
Other
(
11-31- Feed pan cpl MP330 with shut-
        
3555 off and BP-dish

11-31- Feed pan cpl MP330-plus with
         
3565 shut-off and BP-dish

(
11-31- Control pan cpl MultiPan 330
        
3557 with BP dish incl sensor DOL

Control pan cpl MultiPan 330-
11-31-
plus with RPM dish including          
3567
sensor DOL 26

* Observe the weight ranges:  suitable ( suitable to only a limited extent

3.5.5.2 Determine complete lifting capacity for suspended feed lines

Basic unit tube 2 hole with feed pan + feed: 14.7 kg / pc


Basic unit tube 3 hole with feed pan + feed: 18.3 kg / pc
Basic unit 4 hole with feed pan + feed: 21.6 kg / pc
Feed hopper + feed: 90.0 kg / feed line
Drive 20.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 48 System description

3.5.5.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

For the ad-libitum feeding of broilers, turkeys and ducks:


Weight range: 0 - 2.0 kg
(125 : desired end weight kg/bird) + 20
Number of birds per pan:
for example:(125 : 1.25 kg/bird) + 20 = 120 birds / pan
Weight range: 2.0 kg -7.0 kg
95 - (5 x desired end weight kg/bird)
Number of birds per pan:
for example: 95 - (5 x 5 kg/bird) = 70 birds / pan
Weight range: 7.0 kg -12.0 kg
(250 : desired end weight kg/bird) + 25
Number of birds per pan:
for example:(250 : 10.0 kg/bird) + 25 = 50 birds / pan

for rationed feeding:


Number of birds per pan: calculate approx. 25-30% less birds per pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 49

3.5.6 FLUXX Breeder 360

3.5.6.1 Area of use of feed pan and control pan

(respectively 18th - 64th week of life)


1st day until 20th week of life max.

1st day until 64th week of life


Broiler breeders (rearing)
Area of use

Broiler breeders
11-31-3815 Feed pan cpl FXB360 for tube dia 45 BB-rearing 
11-31-3810 Feed pan cpl FXB360 for tube dia 45 BB-rearing & product.  

11-31-3819 Control pan cpl FXB360 d45 BB-rearing + sensor DOL 26 


11-31-3809 Control pan cpl FXB360 d45 BB-rearing & production + sensor DOL 26  

* Observe weight ranges:  suitable

3.5.6.2 Determine complete lifting capacity for suspended feed lines

Basic unit tube 2 hole with feed pans + feed: 14.2 kg / pc


Basic unit tube 3 hole with feed pans + feed: 17.8 kg / pc
Basic unit tube 4 hole with feed pans + feed: 21.8 kg / pc
Drives (all types) 20.0 kg / feed line
Feed hopper 1 feed line + feed: 90.0 kg / feed line
Feed hopper 2 feed lines + feed: 90.0 kg / feed line
Extension 48 l: 32.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 50 System description

3.5.6.3 Feed quantities in the pans

Following feed quantities in grams per pan apply both to the FXB360/
rearing as well as the FXB360 rearing/production.

Feed quantities in grammes per pan with non flooded pan:

Position of the outer cylinder at a not flooded pan


1 2 3 4 5 6 7 8
750 kg/m³ 502 540 569 601 646 721 756 831
Density

650 kg/m³ 435 468 493 521 560 625 655 720
550 kg/m³ 368 396 417 441 474 529 554 609

Feed quantities in grammes per pan with flooded pan:

Position of the outer cylinder at a not flooded pan


1 2 3 4 5 6 7 8
750 kg/m³ 817 847 882 978 1065 1133 1290 1402
Density

650 kg/m³ 708 734 764 848 923 982 1118 1215
550 kg/m³ 599 621 646 718 781 831 946 1028

Use positions 1 to 8 for the feed supply of broiler breeders. The positions
9 to 11 are only used for broiler growing.

3.5.6.4 Dimensions of eating window at FLUXX breeder 360 rearing - production

Possible combination of eating window width and eating window height

Width (mm)
34 38 40 43 44 45 46 47 48 50 53
          
Height (mm)

55
61           
67           
73           AZ

 = adjustment is possible
AZ= Dimensions of eating windows in case of rearing

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 51

3.5.6.5 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

Generally, there is a difference between eating places and animal


places.
A FLUXX Breeder 360 offers 16 eating places which can be calculated
according to the size of the birds, however, may not necessarily be
calculated as animal places.
The animal breed must be observed as well (e.g. Ross 308 or Cobb 500,
etc.) since bigger birds will reduce the number of animal places more than
smaller birds. The indicated values refer to small breeds.

FLUXX breeder rearing (FXB360AZ):


For rearing of broiler breeders (1. day of life up to 20. week of age max.). Males and
females can be fed together or separately as requested.

Day-old chicks: 16.5 birds / pan


week 10: 16 birds / pan
week 20: 15 birds / pan

FLUXX breeder rearing and production (FXB360):


For the rearing of broiler breeders (1st day until 18th week of life) with subsequent
laying phase (approx. 18th to 64th week of life [= „day-old-to-death“]) or only for the
laying phase if there is no rearing.

Day-old chicks: 16.5 birds / pan


week 10: 16 birds / pan
week 20: 15 birds / pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 52 System description

3.5.7 MalePan

3.5.7.1 Area of use of feed pan and control pan

18th - 64th week of life


Broiler breeder males
Area of use
11-31-3585 Feed pan cpl MalePan with shut-off and BP-dish 
11-31-3590 Feed pan cpl MalePan plus with shut-off and RPM-dish 

11-31-3588 Control pan cpl MalePan with BP dish incl. sensor DOL 26 
11-31-3595 Control pan cpl MalePan plus with RPM dish including sensor DOL 26 
11-31-3589 Control pan cpl MalePan-plus with RPM dish including sensor MS 44RG 
11-31-3591 Control pan cpl MalePan-plus with RPM dish excluding sensor 

* Observe weight ranges:  suitable

3.5.7.2 Determine complete lifting capacity for suspended feed lines

Basic tube 2 hole with feed pans + feed: 11.1 kg / pc


Basic tube 3 hole with feed pans + feed: 14.7 kg / pc
Basic tube 4 hole with feed pans + feed: 18.3 kg / pc
Drive (all types) 20.0 kg / feed line
Feed hopper 1 line + feed: 90.0 kg / feed line
Feed hopper 2 line + feed: 90.0 kg / feed line
Extension: 32.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 53

3.5.7.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

for the restrictive feeding of broiler breeder males:


7-9 birds / pan (MalePan)
Number of birds per pan:
7-8 birds / pan (MalePan plus)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 54 System description

3.5.8 Vista 360

3.5.8.1 Area of use of feed pan and control pan

Preparatory and final fattening of turkeys*


Weight

Preparatory and final fattening of ducks*


Kind of feeding

(geese, pheasants, guinea fowls, etc.)*


range

Area of use

Broiler production*
Turkey rearing*

Pullet rearing*
Duck rearing*

controlled

restrictive
ad libitum

0 - 2.5kg

0 - 3.5kg
rationed
Layers*
Other
11-31-4860 Feed pan cpl Vista 360   
11-31-4861 Control pan cpl. Vista 360   

* Observe weight ranges:  suitable

3.5.8.2 Determine complete lifting capacity for suspended feed lines

With maximum feed filling:

Basic unit tube 2 hole with feed pans + feed: 14.2 kg / pc


Basic unit tube 3 hole with feed pans + feed: 17.8 kg / pc
Basic unit tube 4 hole with feed pans + feed: 21.8 kg / pc
Feed hopper + feed: 90.0 kg / feed line
Drive 20.0 kg / feed line
If halving of loads is applied, only half of the calculated total weight has to be
considered for selecting the cable winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 55

3.5.8.3 Recommended numbers of birds

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

for the ad-libitum feeding of broilers:


Weight range: 0 - 3.5 kg

((125 : desired final weight kg/bird) + 20) x 1.12


Example calculation: for example:
((125 : 1.25 kg/bird) + 20) x 1.12 = 134 birds/pan

up to 1.5 kg final weight = 112 birds


up to 2.0 kg final weight = 95 birds
Number of birds per pan: up to 2.5 kg final weight = 78 birds
up to 3.0 kg final weight = 73 birds
up to 3.5 kg final weight = 61 birds

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 56 System description

3.5.9 Feeder 30 ltr Empa 2 (20-00-3930)

Technical data:

Contents approx: 30 l
Pan diameter: 510 mm
Height of pan rim: 120 mm
This self-feeder is designed for manual or restricted feeding of adult males from 2.5 to
4.5 kg live weight in broiler breeder production houses (laying).
Turkeys of 5 to 6 weeks of age can be fed with this feeder as well. This means that the
self-feeder is designed for turkeys with a live weight of 2 to 2.5 kg up to their maximum
finishing weight as well.

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

Recommended number of birds per feeder Empa 2:

Birds / Feeder Feeding method


Broiler breeder males production period as
16 restrictive
from week 16 / 18
Turkeys with a live weight of up to 12 kg 51 ad libitum
Turkeys with a live weight of up to 20 kg 33 ad libitum
In case of higher bird weights for growing/production, the number of birds per feeder
has to be reduced.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 57

3.5.10 Feeder 30ltr Empa 3 (20-00-3940)

Technical data

Contents approx: 30 l
Pan diameter: 375 mm
Height of pan rim: 70 mm
This feeder has a more flat and smaller feed dish with regard to the diameter. Therefore
it is particularly suitable for laying hens with a live weight of up to 2.2 kg and the rearing
of broiler breeder males until week 16 / 18.

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

Recommended number of birds per feeder Empa 3:

Birds / Feeder Feeding method


Broiler breeder males
17 restrictive
rearing until week 16/18
Laying hens with a live weight of up to 1.5
104 ad libitum
kg
Laying hens with a live weight of up to 2.2
92 ad libitum
kg
In case of higher bird weights for growing/production, the number of birds per feeder
has to be reduced.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 58 System description

3.5.11 Feeder 30ltr Empa 4 (20-00-3950)

Technical data:

Contents approx. 30 l
Pan diameter: 410 mm
Height of pan rim: 80 mm
This self-feeder is designed for manual or restricted feeding of adult males from 2.5 to
4.5 kg live weight in broiler breeder production houses (laying).
Turkeys of 5 to 6 weeks of age can be fed with this feeder as well. This means that the
self-feeder is designed for turkeys with a live weight of 2 to 2.5 kg up to their maximum
finishing weight as well.

!
The number of birds stated here are approximate and may vary according
to breed, stocking rate and ambient conditions. Please obtain advice on
this from your stock supplier. Different provisions, e.g. national regulations
must also be taken into account.

Recommended number of birds per feeder Empa 4:

Birds / Feeder Feeding method


Broiler-breeder-males production period as
16 restrictive
from week 16 / 18
Turkeys with a l.w. of up to 12 kg 51 ad libitum
Turkeys with a l.w. of up to 20 kg 33 ad libitum
Due to a flat feed dish the feeder Empa 4 is suitable both for laying hens with a weight
of up to 2.2 kg and the rearing of broiler breeder males until week 16 / 18.

Recommended number of birds per feeder Empa 4:

Birds / Feeder Feeding method


Broiler breeder males
17 restrictive
rearing until week 16 / 18
Laying hens with a l.w. of up to 1.5 kg 104 ad libitum
Laying hens with a l.w. of up to 2.2 kg 92 ad libitum
In case of higher bird weights for growing/production, the number of birds per feeder
has to be reduced.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
System description Page 59

3.5.12 Feeder 12 ltr Picorett (11-31-3080)

Technical data:

Contents approx.: 12 l
Pan diameter: 360 mm
Height of pan rim: 45 mm
Total height without cover: 280 mm
Total height with cover 370 mm
This feeder is particularly suitable for the chick rearing, especially for turkey chicks in
chick rings.
After the rearing in a chick ring, the feeder 12 ltr Picorett can be connected to the
Augermatic system instead of a feed pan and can thus be filled automatically.
The feeder 12 ltr Picorett offers the following advantages:
• Less chick losses
The low pan rim even allows day-old chicks easy access to the feed.
• Less feed losses
The feed level can be adapted to the birds' age and the flowability of the feed.
• Increased feed conversion
The chicks cannot stand nor sleep in the pans. The feed does not get soiled. A
cover protects the feed against dust, preventing the birds from entering the feed
hopper.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 60 Operating Instructions

4 Operating Instructions

The following aspects should be considered before operating


the installation!
• Initial operation must have been carried out by a qualified
Caution
technician with the respective proof of knowledge (service
technician).
• The installation's operator must have received all minutes
required by Big Dutchman and completely filled out:
confirmation minutes and the additional inspection protocols, if
applicable.

4.1 Important information

Carry out any work in the house quietly. The birds should not be scared or
startled.
Avoid unusually stressful situations in the house.

!
Important
If the house is disinfected thermally, please consider that the temperature
must not exceed 60°C.
Temperatures above 60°C can cause damage to the house equipment. In
particular, there is a risk that the plastic parts deform.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 61

4.2 Management recommendations for the housing and production

Correct and efficient management before and during the whole grow-out can
significantly increase and improve the productive capacity.
The first days of the chicks' lives are most important as these are highly influential on
the further development of the birds. This is why the preparations for the moving-in
procedure should be understood as an important part of successful production. The
following factors should be considered:

4.2.1 Preparations for the moving-in procedure

4.2.1.1 Airing / ventilation

The house should be aired well before heating so that no harmful gases from the
disinfection remain in the house.
The CO2 level in the house should not amount to more than 3,000 ppm when the birds
are moved in as a higher level could negatively influence the fattening performance. A
good air quality and an even air temperature are the best conditions for an optimal
development of the birds.
The birds can only be supplied with fresh air if the house is sealed and insulated well.
Unplanned air entrances in the walls should be closed as soon as possible.
Part of the climate is also the air humidity, not just the temperature. These two should
always be considered together. In the following, please find a table which illustrates that
you can lower the house temperature if the humidity is constantly high.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 62 Operating Instructions

Table 4-1: Temperature and humidity as a function of bird age

Normal set value Temperature and humidity


Age Temp. °C Humidity Ideal
(Days) 40% 50% 60% 70% 80%
0 30.0 60-70 36.0 33.2 30.8 29.2 27.0
3 28.0 60-70 33.7 32.1 28.9 27.3 26.0
6 27.0 60-70 32.5 29.9 27.7 26.0 24.0
9 26.0 60-70 31.3 28.6 26.7 25.0 23.0
12 25.0 60-70 30.2 27.8 25.7 24.0 23.0
15 24.0 60-70 29.0 26.8 24.8 23.0 22.0
18 23.0 60-70 27.7 25.5 23.6 21.9 21.0
21 22.0 60-70 26.9 24.7 22.7 21.3 20.0
24 21.0 60-70 25.7 23.5 21.7 20.2 19.0
27 20.0 60-70 24.8 22.7 20.7 19.3 18.0
Table 4-1 illustrates the relation between air humidity and effective temperature. If the
relative air humidity is not within the desired range, the temperature should be
adjusted, as shown in the table. This means that the house temperature should be
raised if the air humidity is lower than 60 percent.
Constantly check the birds' behaviour to ensure a good start of the fattening period and
a good daily weight gain.

Key points airing / ventilation

• Check the daily bird weight to achieve the desired weight for day

!
seven by adjusting humidity and temperature, if necessary.
• Monitor the birds' behaviour to be able to judge the climate conditions.
• Use the temperature and the minimum ventilation to stimulate the
birds' activity and appetite.
• If possible, try to maintain an air humidity of 60 to 70 percent during
the first three days and later a humidity of more than 50 percent.
• If necessary, reduce the temperature if the humidity exceeds 70
percent and monitor the birds' behaviour.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 63

4.2.1.2 Heating / heat requirements

Chicks cannot regulate their body temperature on their own during the first week of
their life, which is why the ambient temperature in the house plays an important role
when they are moved in. If the house temperature is not at an optimum, this means a
lot of stress for the chicks, which in turn influences their feed and water consumption
and their development negatively.
Before the birds are housed in, the house should be heated up to an appropriate
temperature. This should be done in time so that the brickwork can take the
temperature as well. If the floor is cold when the litter is deposited, this may lead to
moist litter. It is important that the heat is distributed evenly in the entire house.
30°C are a good moving-in temperature. However, you should ask your breeder for the
temperature ideal for your birds.
The house temperature should be checked regularly during the heating phase and
adjusted where necessary.

The best indicator for the temperature is the behaviour of the birds.

If the temperature is too low, the birds will crowd together and groups are formed.
In case of too high temperatures, the birds will lie in the litter with splayed wings and
open beaks. An equal distribution of the birds shows that the temperature is optimal.

4.2.1.3 Feed supply

Before the feed lines can be filled with feed, they must be moved to the lowest position.
In order to activate the flooding mechanism (e.g. at FLUXX) the feed pans must stand
in the litter and the Augermatic tube has to be lowered to the outer cylinder of the feed
pans (4.3.9 ”Automatic flooding mechanism”).
In order to flood the pan manually (e.g. at BigPan), the pan must be turned shortly. If
this pan stands on the floor, it cannot be flooded.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 64 Operating Instructions

automatic flooding mechanism manual flooding


(by short turning of the feed pan / only
possible with suspended pan)
The flooding mechanism causes a higher feed level (see figure: flooded pan). The pans
remain in this position during the first three days, thus facilitating the chicks' access to
feed.

Figure 4-1: Feed pan in the litter

The feed lines can now be supplied with feed one after the other. After all feed lines
have been supplied, you should check if all pans are filled sufficiently.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 65

4.2.1.4 Feeding system

The feed line Augermatic is supplied with feed from one or more silos by means of a
feed circuit (1). The Flex-Vey line (2) transports the feed from the silo into the house.
The feed is transported to the feed pans (3) via the auger HD AM. The feed line is
controlled via sensors in the control pans. This is always mounted as one bast last pan
in front of the drive.

• Make sure that all feed pans with grille (if available) are closed tightly!
• From the third day of life, the automatic flooding mechanism is
deactivated by lifting the Augermatic line. The pans must remain on
the floor. The feed in the pan remains on the level adjusted at the pan.
(4.3.9 ”Automatic flooding mechanism”).
The feed level in the pan is regulated by an adjustment mechanism.
When adjusting the feed level, remember to consider the feed type
and texture. The feed level in the pan depends on the feed
composition (meal/pellets).

For further information regarding the feed level adjustment see chapter 4.3 ”The feed
pans”.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 66 Operating Instructions

4.2.1.5 Water supply

Before moving the birds in, all drinker lines should be cleaned thoroughly with clean
water to remove cleaning agents and disinfectants. The drinker lines should be moved
to the lowest position so that the chicks can easily and quickly find the water. The lines
should only be filled with fresh and clean water shortly before moving the birds in. Make
sure that all nipples are functioning correctly. A water drop should be visible at each
nipple so that the chicks can easily find the water.

Follow the manual „Drinking systems / User Manual“.

Key points preparations for the moving-in procedure

• Heat the house before moving the birds in until a temperature of 30°C

!
is reached at the bird level. Make sure that the brickwork is also
heated sufficiently in order to avoid moist litter.
The correct moving-in temperature is the most important factor and
significantly influences the fattening process.
• Fill the feed line shortly before moving the birds in so that they can
immediately start eating.
• The feed pans should be flooded for the first days to facilitate feed
intake.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 67

4.2.2 Place birds

All chicks should be moved into one house at once (ideally within one or two days).
Experience shows that the feed composition should be adapted to the fattening age. If
there are birds with different ages in one house, the feed cannot be exactly adapted to
the bird age. This would mean that the different developmental stages of the birds could
not be optimally supported and the birds would not reach their full production
performance. There would also be disadvantages regarding hygiene and health.
To avoid germs inside the house, the hygiene management should be considered very
important. Vehicles, equipment and staff should be disinfected before entering the farm
area.
The chicks should be distributed in the litter quickly and carefully as soon as they are
delivered. The longer the chicks stay in the boxes, the larger the risk of dehydration.
Possible consequences include increased mortality during the first days and slow
weight gain.

Follow the manual „Drinking systems / User Manual“.

!
The chicks should be left alone for approximately one hour after moving-
in so they can relax and familiarise themselves with the new environment.
After this hour, check if all chicks can easily access water and feed. The
equipment and the temperature should be adjusted if required.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 68 Operating Instructions

Key points for the first days after moving the birds in

• During the first days after moving the birds in, make sure that all birds
have found feed and water.

!
• The light should be turned on at 100 percent during the first seven
days.
• On the first morning after moving the birds in, check if their crops are
filled with feed and water. The crops of birds which have taken in water
and feed are full, soft and rounded. If the crop is filled and hard, the
bird ate but did not drink.
– 95 to 100 percent of crops should be filled 24 hours after moving-
in.
• The flooding mechanism should be turned off starting with the third
day. To achieve this, the Augermatic line is lifted while the feed pans
remain on the floor (4.3.9 ”Automatic flooding mechanism”).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 69

4.2.3 Daily tasks

Check the following every day after the lights are switched on in your house:
• functioning of the feeding systems (exact monitoring of the feed consumption can
provide valuable information for bird management),
• house climate (ventilation, house temperature),
• lighting
• physique and behaviour of the birds,
• bird distribution.
• birds' health,
• mortality,
• manure composition.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 70 Operating Instructions

4.2.3.1 House temperature

Temperature
The ideal house temperature depends on the birds' age. Day-old chicks need a warm
climate to have a good start.
Apart from the sealing of the building, it is important to distribute fresh air evenly in the
house. Depending on the installed system, fresh air chimneys suck air into the building
without using a high negative pressure and distribute air by means of spreader discs.
The negative pressure is later increased continuously and may amount to 25 pascal -
if the ceiling chimneys are completely opened - before the fresh air is supplied by side
wall inlets.
If these fresh air chimneys used in colder climate zones are not installed, air is taken in
cyclically during the first days by opening the inlets at both side walls. To move warmed
air into the middle of the building in a house with a width of 18 meters, a negative
pressure of approximately 25 pascal is required.
It is important to set the spoilers above the inlets in a way that the airflow is not
deflected by obstacles at the ceiling.
Apart from the temperature and the humidity, the computer also calculates the correct
air speed in accordance with the birds' age. The values which the computer tries to
reach or to not exceed depend on the system similar to the following table:

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 71

Airing / ventilation
Again, the birds' behaviour must be monitored closely.
Birds lie flat on the floor and are hiding from the air flow = increase the temperature to
reduce ventilation and air speed.
Birds are panting = increase the air speed by reducing the temperature and thus
increasing the ventilation level.
Birds are panting in spite of an adequate air speed = start cooling earlier.
The most efficient method to distribute air correctly in the house is minimum ventilation,
which is connected with the negative pressure procedure. With this system, fresh air
coming in through the air flaps will move to the top of the house and mix with the warm
air. The lateral air flaps at the opening shall be opened at least five centimetres wide to
ensure a good mixing of air in the house. The house should be insulated well to
guarantee optimal functioning of the ventilation system. The perfect air speed at bird
level is very important throughout the whole grow-out and especially during the
beginning of the batch.

Table 4-2: Air speed as a function of the bird's age and airing system

System
Day Combi-Tunnel Combi-Cross-Tunnel
1 0.2 m/s 0.2 m/s
7 0.3 m/s 0.3 m/s
14 0.4 m/s 0.4 m/s
21 0.6 m/s 0.6 m/s
28 1.5 m/s 1.0 m/s
35 2.5m/s 1.6 m/s
42 3.5 m/s 1.6 m/s
49 3.5 m/s 1.6 m/s

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 72 Operating Instructions

Caution!
Never turn off components of the exhaust air or fresh air systems. The air
speed is essential after a certain age.

!
Never turn the cooling system on or off uncontrolled or manually.
Excessive air humidity in combination with too high temperatures can
cause the birds' death.
Alarm system:
Always make sure that the alarm system is active and tested regularly as
prescribed.
Power supply:
Ensure that power is supplied at any time and plan for the case of
emergencies. Train your farm staff according to these plans. Compared to
floor management, cage systems develop more heat, which requires
faster action.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 73

4.2.3.2 Feeding

During the first week of life until approximately day ten, the feed pans should stand on
the floor. This facilitates the chicks' access to feed. As feed is the largest expense factor
for broiler production, the feed pans should be lifted from day eleven so that the pan
rim is level with the back of the birds. Feed wastages can be prevented by the regularly
adjusting the feed pan height to the bird age.

Check the optimum height adjustment of the feed pans.


A too low adjustment of the feed pans leads to increased feed losses and
feed soiling.
If feed pans are adjusted too high, birds are impeded during feed
consumption which can lead to deformations of the skeleton.

! For the height of the feed pans, the following rule-of-thumb generally
applies:
Height of the birds' back = height of the pan rim!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 74 Operating Instructions

Key points for the daily inspection of birds

Check and document the following every day after the lights are switched

!
on in your house:
• functioning of drinker and feed lines (exact monitoring of water and
feed consumption can provide valuable information for bird
management),
• careful selection of birds and daily documentation,
• house climate (ventilation, house temperature),
• health and behaviour of the birds,
• manure composition.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 75

4.2.4 Preparation of the moving-out procedure

4.2.4.1 Climate before and after moving the birds out

Before moving the birds out:

Caution! Risk of suffocating or heat stroke!

The risk lies in the fact that the house gets too cold so that the ventilation system
automatically lowers the ventilation level. This means that neither fresh air nor heat are
transported into the house.
Prevent this from happening by specifically adjusting the minimum ventilation so that
the computer cannot lower the ventilation to a dangerous level. Checking the house
climate after long moving-out procedures is essential.

After moving the birds out:


If the moving-out procedure is paused at the end of the day, set all values back and
reset all settings carried out manually at the control cabinet and the alarm system.

4.2.4.2 Light

To ensure that the herd is calm during the moving-out procedure, the dark phases have
to be shortened. This should take place three days before moving the birds out.

4.2.4.3 Shutting off the feed supply

The feed supply has to be shut off approx. 10-12 hours before the birds are moved out
to ensure that no feed remains in the line, thus facilitating the cleaning process later.
As soon as the remaining feed has been transported into the feed pans, all drive units
of the feed line have to be turned off. This prevents unnecessary wear of the feed line.
The birds should have access to water as long as possible and only be blocked from it
if absolutely required.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 76 Operating Instructions

Key points for the preparation of the moving-out procedure

! •

Shorten the dark phase 3 days before moving the birds out.
Turn off the feed supply 10 - 12 hours before moving the birds out.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 77

4.2.5 After the moving-out procedure

Big Dutchman would like to remind you that all proceedings on your farm, including
the moving-out procedure, should be carried out very carefully regarding safety and
health of the staff. Please ensure appropriate clothing and anything else the staff might
need to carry out their tasks. Please instruct your staff to keep away from moving parts
of the installation which could lead to injuries; also refer to the notes on the installation
and the information in the manuals.

Key points after the moving-out procedure

! • Pay attention to moving parts of the installation.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 78 Operating Instructions

4.3 The feed pans

4.3.1 General features of the feed pan

• large, inwardly directed pan rim


= feed saving collar, feed losses are prevented

• pan can be mounted free swinging or rigidly at the tube


= always animal-friendly

• softly shaped pan rim


= no chest bruising during the final fattening.

4.3.2 BigPan 330

4.3.2.1 Features:

• Manual flooding: if the pan is swinging freely, the pan can easily be flooded for the
day-old chicks by simply spin it slightly
= no extra work for adjusting the feed level

• V-shaped bottom is seated deeply in the litter


= ideal for day-old chicks

• Slide shut-off
= for closing the pan

• Especially birds of more than 2 kg live weight are fed in a controlled manner. In this
way, the development of the cardio-vascular system and the skeleton can keep
pace with the increase in weight.
An essential prerequisite is that the feeding system distributes the feed rapidly
throughout the entire house upon each feeding time. The volume reducing insert
in combination with the sectional dish reduces the feed volume by approx. 2/3. This
allows filling the pans of one line with feed very rapidly.

• less damages to the skeleton, less leg and foot problems;


• improved feed conversion due to smaller fat deposits and lower mortality rate;
• precise attainment of the bird weights desired for the day of slaughter.
• The BigPan Plus is also suited for rearing ducks up to a weight of 2.5 kg. The
shallow sectional dish provides an optimum start of the ducklings, only requires a
small layer of litter and prevents feed losses.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 79

• Furthermore, ducks can very easily feed from the pan due to its sectional shape.
The grille prevents birds from entering the pan = thus preventing soiling of feed.
• BigPan 330 and BigPan Plus can also be used for rearing pullets and for feeding
layers. Supplementary wheat feeding can be a good alternative in growing broilers
for saving feed costs and for improving the birds' health.
The technical requirements for this are a second silo, the FW 99-B feed scale,
conveying augers (Flex Vey) from the silo to the scale and to the feeder as well as
the MC 95 production computer respectively Viper Touch (with full-broiler-
package). MC 95 / Viper Touch allows continuous adjustment of the portion of
wheat to the total ration according to the birds' development. Feed is mixed with
wheat via the weighing drum and the collecting basin.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 80 Operating Instructions

4.3.2.2 Adjusting the feed level

Pull at the brackets of the outer cylinder and adjust the desired feed level position. On
the left you'll find the uneven feed level positions and on the right you'll find the even
numbers.

According to experience, position 4 is the


optimal feed level adjustment which
should be chosen initially for the BigPan.

smallest feed level adjustment largest feed level adjustment

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 81

4.3.3 FLUXX

4.3.3.1 Features:

• automatic flooding mechanism: as long as the feed pan is standing in the litter and
the Augermatic tube is lowered to the outer cylinder of the feed pans, the pan is
flooded automatically (4.3.9 ”Automatic flooding mechanism”).
= high feed level, ideal for day-old chicks.

• 5 or 8-arm resp. 14 or 16-arm grille, consisting of flexible grille bars


= feed is easily accessible for all birds

= day-old chicks can easily get in and out of the feed pan

• corrugated flat pan bottom


= ideal for day-old chicks at a low litter height

• V-shaped bottom is seated deeply in the litter


= ideal for day-olds

• baffles rotate with the outer cylinder


= prevents feed wastage

= for easy and thorough cleaning

• in suspended position, the pan is not flooded


= low feed level

= always fresh feed in the pan

= no feed wastage

• The broiler pan FLUXX not only satisfies the needs of day-old chicks, but also
those of heavy birds in the final grow-out phase.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 82 Operating Instructions

• As the birds grow, the entire feed line is raised which causes the flooding
mechanism to close thus decreasing the feed level inside the pan. This reduces
feed wastage (4.3.9 ”Automatic flooding mechanism”).
• Baffles at the outer cylinder of the pan additionally prevent feed wastage as they
keep the birds from pushing feed out of the pan.
• There are different models of FLUXX available:
• with a diameter of 330 or 360 mm
• with 5- or 14-arm grille respectively 8- or 16-arm grille;
• with deep pan or corrugated bottom
• with or without shut-off

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 83

4.3.3.2 Adjusting the feed level [FLUXX 330]

On the top surface of the grille you'll find the numbers 1-7. These are
required for the adjustment of the different feed level positions. The arrow
on the cylinder outer must be adjusted centrally to the number of the
respective feed level position.

!
The feed pan shown in the
figure below, for example is
adjusted to feed level 1.

According to experience, position 3 is the optimal feed level adjustment which should be
chosen initially for the FLUXX 330.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 84 Operating Instructions

4.3.3.3 Adjusting the feed level [FLUXX 360]

On the top side of the grille you'll find the numbers 1-11. These are
required for the adjustment of the different feed level positions. The arrow
on the cylinder outer must be adjusted centrally to the number of the
respective feed level position.

!
The feed pan shown in the
figure below, for example, is
adjusted to feed level 1.

The levels 9-11 may only be


adjusted if the feed pan
FXB 360 (83-01-6343) is used!

According to experience, position 6 is the optimal feed level adjustment which should be
chosen initially for the FLUXX 360.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 85

4.3.4 BigPan 2

4.3.4.1 Features:

• Manual flooding: if the pan is swinging freely, the pan can easily be flooded for the
day-old chicks by simply spin it slightly
= no extra work for adjusting the feed level

• The BigPan2 combines the features of the BigPan with the spin’n lock-technology
of the feed pan FLUXX
• Simple feed level adjustment
• 7 feed level adjustments are possible

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 86 Operating Instructions

4.3.4.2 Adjusting the feed level

On the top side you'll find the numbers 1-7. These are required for the
adjustment of the different feed level positions. The arrow on the cylinder
outer must be adjusted centrally to the number of the respective feed level
position.

!
The feed pan shown in the
figure below, for example, is
adjusted to feed level 1.

According to experience, position 3 is the optimal feed level adjustment which should be
chosen initially for the BigPan 2.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 87

4.3.5 MultiPan

4.3.5.1 Features:

• Manual flooding: if the pan is swinging freely, the pan can easily be flooded for the
day-old chicks by simply spin it slightly
= no extra work for adjusting the feed level

• Can be used with or without feed saving collar.


• Engraving for precise adjustment of feed level in the pan.
• These feed pans were specially designed for alternative growing of broilers,
turkeys, ducks and other growing poultry (guinea fowls, pheasants, geese) up to a
live weight of 12 kg. Depending on the type of bird and feeding (ad libitum or
controlled), MultiPan or MultiPan Plus can be used.
• Both pans are equipped with a slide shut-off.
• For growing poultry up to approx 2.5 kg live weight as well as rearing of turkeys and
ducks, the pans are used without feed saving collar.
• From a live weight of approx. 2.5 kg upwards, the collar can be installed to minimize
feed losses.
• For controlled feeding, place a volume reducing insert into MultiPan Plus, reducing
the feed volume by approx. 2/3 in combination with the sectional dish. This ensures
rapid and uniform filling of all pans in one line immediately at the beginning of the
feeding.
• The sectional dish is ideally suited for ducks since they can feed easily due to the
shape of their beak.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 88 Operating Instructions

4.3.5.2 Adjusting the feed level

Pull at the brackets of the outer cylinder and adjust the desired feed level position. On
the left you'll find the uneven feed level positions and on the right you'll find the even
numbers.

According to experience, position 5 is the


optimal feed level adjustment which should be
chosen initially for the MultiPan.

smalles feed level position largest feed level position

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 89

4.3.6 FLUXX Breeder 360

4.3.6.1 Features:

• automatic flooding mechanism: as long as the feed pan is standing in the litter and
the Augermatic tube is lowered to the outer cylinder of the feed pans, the pan is
flooded automatically (4.3.9 ”Automatic flooding mechanism”).
= high feed level, ideal for day-old chicks.

• 16 eating places per feed pan; allow for a higher bird density and consequently less
investment costs per bird.
• feed level can be adjusted in 11 steps by one's own hand and cannot be adjusted
accidentally (spin ´n lock technology).
• 8 baffles at the circumference of the outer cylinder prevent feed losses.
• an integrated volume reducing insert allows for very small feed quantities per pan
and therefore a quick and equal filling of each feed pan on one circuit at the same
time; condition for a high uniformity of the flock.
• New locking mechanism between pan and grille allows for an easy opening of the
feed pan for cleaning purposes; less work.
• The specially formed dish has 4 cleaning openings. Even if it is closed, remaining
liquid of cleaning and disinfection can drain; no more accidental consumption of
highly concentrated disinfectants.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 90 Operating Instructions

Besides the above-mentioned features the Fluxx Breeder 360 rearing and
production (FXB360) has the following additional features:
• Special "female-only mechanism" which allows for the adjustment of 11 eating
window widths without having to open the feed pan.
• The levelling ring allows for the automatic adjustment of 4 eating window heights.

There are 44 possible combinations for the highest flexibility. Thus the
FXB360 is suited to keep the males away from the females’ feed for all
BB-breeds which makes it an ideal investment with a great future.

• An additional function of the levelling ring is the heightening of the pan rim when
the eating window height is reduced. This helps to minimise feed losses.
• Good illumination of the pan thanks to openings in the upper part of the inner grille
makes it easier for the birds to find the feed.

4.3.6.2 Minimum sensor at lower part for feed hopper

The lower part for feed hopper is equipped with a minimum sensor. It stops the
Augermatic drive after the daily amount of feed is distributed and the Augermatic
hopper runs empty. Thus, unnecessary noise and excessive wear of the system are
prevented.
• For an impeccable operation of the Augermatic line with FXB 360/FXB 360 rear.,
the birds have to eat sufficiently from the control pan.

Prevent cold, windy and uncomfortable areas around the control pan!

• Make sure that enough feed is replenished!

At least one Flex-Vey 75 per Augermatic line with lateral feeding!


At least one Flex-Vey 90 per Augermatic line with central feeding!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 91

• Feed pans may be empty before the ration is fully distributed if ...

...the conveying tubes of the feed line turn empty due to repeated short
starting.
...the birds prefer to stay in the centre of the house. The birds eat thus
more from those feed pans, which are thus emptied quicker than those in
the surrounding areas.
...the birds do not eat sufficiently from the control pans or if the feed level
in the control pans is too high.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 92 Operating Instructions

4.3.6.3 Adjusting the feed level [FLUXX Breeder 360 broiler breeder rearing]

On the top side of the grille you'll find the numbers 1-11. These are
required for the adjustment of the different feed level positions.The arrow
on the cylinder outer must be adjusted centrally to the number of the
respective feed level position.

!
The feed pan shown in the
figure below, for example, is
adjusted to feed level 1.

According to experience, position 4 is the optimal feed level adjustment which should initially
be chosen for the FLUXX Breeder 360 (broiler breeder rearing).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 93

4.3.6.4 Possibilities for adjustment


[FLUXX breeder 360 broiler breeder rearing & production]

On the top side of the grille


inner you'll find the numbers 1-

!
11.
These are required for the
different feed level position.
The arrow on the cylinder outer
must be adjusted centrally to
the number of the respective
feed level adjustment.
The feed pan shown in the
figure below, for example, is
adjusted to feed level 1.

According to experience, position 4 is the optimal feed level adjustment which should initially
be chosen for the FLUXX Breeder 360 (broiler breeder rearing & production).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 94 Operating Instructions

Slide shut-off closed Slide shut-off opened


(grille inner fixed with grille outer) (grille outer can be turned)

Push the slide shut-off only up to the limit


stop, otherwise the slide shut-off may fall
from the grille and could get lost!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 95

Possible combination of eating window width and eating window height

Width (mm)
34 38 40 43 44 45 46 47 48 50 53
          
Height (mm)

55
61           
67           
73           AZ

 = adjustment is possible
AZ= Dimensions of eating windows in case of rearing

On the grille outer you'll find 4 groups of figures totally (X). Each single
figure group refers to a height step of the eating window at the levelling
ring.

On the grille
outer you'll find 4
groups of figures
totally. Each
single figure
group «X» refers
to a height step
of the eating
window at the
levelling ring.

Height
adjustment:

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 96 Operating Instructions

6. Turn the grille outer until you have achieved the required height adjustment of the
levelling ring (the value of the levelling ring corresponds to the height in mm).

Figure 4-2: smallest height of the eating Figure 4-3: largest height of the eating
window window

Width adjustment:

7. Turn the grille outer within this figure group in order to adjust the width of the eating
window (value at the grille outer corresponds to the width in mm). Close the slide shut-off
in order to lock the grille outer.

Figure 4-4: smallest width of the eating Figure 4-5: largest width of the eating
window window

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 97

4.3.7 MalePan

4.3.7.1 Features:

• Fixed, not swinging tube connection via a compression spring and a holding pin.
• Shut-off for an equal distribution of the limited feed quantity on all males of the
breed with decreasing number of birds (mortality/selection).
• Stable 5-arm grille
• Deep pan to prevent feed wastage and for complete consumption of the required
daily rations for males.
• Numerical scale with exact and simple volume adjustment of all pans in a feeding
line.

4.3.7.2 Introduction

In broiler breeder houses, the separate sex feeding still has a very high production-
technical status.
This is important:
• to give a little smaller feed quantity to the males than to the females
• to control the sexual development of the males
• to avoid an uncontrolled weight gain as well as an early obesity.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 98 Operating Instructions

On the other hand, a feed recipe deviating from that of the hens shall also be offered
in individual cases.Separate male-female feeding ("separate sex feeding") can be put
into practice as follows:
• The males must be denied access to the feed of the females by means of a
relatively narrow eating grille.
• At the same time, a feeding place has to be offered to the males which cannot be
reached by the smaller hens due to its raised position.
Since the males are fed extremely restrictively as are the females, such a male feeding
system has to fulfil special requirements in order to give each male its exact daily ration.
Here, we distinguish different feeding procedures,
• according to the kind of quantity fixing
• and even distribution of the feed to the males.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 99

4.3.7.3 MalePan

Distribution of the daily ration by lowering the filled MalePan at the feeding time:
Here, we have the possibility to fix the daily ration per male:
• only by the volume adjusted at the outer cylinder of the "Male Pan",
• or to weigh the feed into the feed hopper additionally for a more exact fixing of the
feed quantity.

Advantages of the MalePan:


• The equal distribution of the feed ration is independent of the conveying lengths
and can be carried out up to 145 m from the gable.
• Every male obtains exactly the same volume (quantity) of feed.
• Thanks to the mostly suspended male feeding line, the birds have more place in
the scratching area. Through this, the insemination rate is improved. The danger
of misplaced eggs under the male pan is minimised.
• 7 - 9 males per feed pan.

Technical details of the feed pan MalePan:


(daily lowering of the filled Male-Pan at feeding time)
Possible grid positions of the Male-Pan and the corresponding feed quantities.

Grid position at the [.] 1 2 3 4 5 6 7 8 9 10 11 12


outer cylinderr
Feed volume (cm³) 1111 1162 1254 1384 1535 1703 1885 2078 2284 2505 2731 2973
Spec. density (g/cm³) 0,65
Feed quantity (g) 722 755 815 899 998 1107 1225 1351 1485 1626 1775 1932
= for 7 males (g/bird 103,1 107,9 116,4 128,5 142,5 158,1 175,0 193,0 212,1 232,3 253,6 276,0
= for 8 males (g/bird 90,2 94,4 101,8 112,4 124,7 138,4 153,1 168,9 185,6 203,3 221,9 241,5
= for 9 males (g/bird) 80,2 83,9 90,5 99,9 110,9 123,0 136,1 150,1 165,0 180,7 197,3 214,7

The calculated feed quantities should only be regarded as reference values.


Since the flowability of the feed in the pan also depends on the surface structure and a
lot of other factors - apart from the special density, the humidity and fat contents - it is
absolutely necessary to measure the feed quantities with the sort of used feed.

Process of the feeding in principle with volume dosing:


1. The feed line is suspended inaccessible for the males.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 100 Operating Instructions

2. The feed hopper of the Augermatic is continually kept filled by an auger or a Flex-
Vey conveying auger. The daily ration is not weighed in.
3. The Augermatic conveying auger is switched on. The feed pans MalePan are then
filled one after another from the feed hopper to the drive unit. The feed quantity
depends on the height adjustment of the outer cylinder as well as the adjusted
volume of the feed quantity.
4. The "full" sensor of the last but one feed pan will switch off the Augermatic
conveying auger.
5. The Augermatic conveying auger is switched currentless and is lowered
automatically or manually to bird level. In this lowered position, there is generally
no refill of the MalePan feed pans.
6. After that, the system is suspended again and filled for the next day.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 101

4.3.7.4 MalePan Plus

Distribution of the daily ration during the eating time - without daily lifting and
lowering of the MalePan feed pans:
The complete daily ration for the males is distributed during the feeding and eating
time; it is not necessary to lift or lower the feed pans in a daily change. In order to
guarantee an even distribution of the feed quantity to all birds, the following techniques
of Male-Pan plus are described.
• A minimum sensor in the feed hopper keeps the Augermatic conveying auger filled
between two feed pans so that feed will be available in all feed pans immediately
after having switched on the drive.
• The conveying capacity of the Augermatic is increased to more than 1 t/h thanks
to a special drive unit.
• The integrated volume reducing insert reduces the amount of feed in the feed pan,
thus ensuring a quick refilling after the beginning of the feeding.
• The trough-shaped feed dish realises an extremely flat feed level. Through this the
feeding speed of all birds is adapted to a low level.

Advantages of the MalePan-plus:


• The feed pans must not be lifted or lowered every day.
• Every male obtains the same amount of feed.
• A flat feed level in the trough-shaped feed pan will reduce feed wastage.
• 7-8 males per feed pan.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 102 Operating Instructions

Technical details of the feed pan MalePan Plus:


(distribution during the feeding time - without daily lowering of the feed pans)
General process of the feeding procedure:
1. The complete daily ration for the males of this feeding line is weighed into the feed
hopper.
2. The Augermatic conveying auger is switched on for feeding. The Male-Pan plus
feed pans are all filled simultaneously with the feed quantity located in the
conveying tube between two feed pans.
3. The maximum sensor of the last but one feed pan controls the Augermatic
conveying auger according to the actual eating performance of the birds.
4. The minimum sensor at the bottom of the feed hopper of the Augermatic switches
off feeding. In this way, the conveying tube is still filled with feed and is therefore
prepared for the next day.

General process of the feeding procedure at the weight dosing:


1. The feed line is suspended inaccessible for the males.
2. The entire daily ration for the males of this feed line is weighed in the feed hopper.
3. The Augermatic conveying auger is switched on. The MalePan feed pans are then
filled one after another from the feed hopper to the drive unit.
4. The minimum sensor in the feed hopper of the Augermatic system switches off the
Augermatic conveying auger when the entire amount of feed weighed in has been
distributed.
5. If the "full" sensor of the last but one feed pan stops before, the height adjustment
at the outer cylinder of all feed pans must be modified that way that the entire daily
ration can be consumed.
6. Only a very small amount of feed should remain in the feed hopper which should
be the same from day to day.
7. The Augermatic conveying auger is switched currentless and is lowered
automatically or manually to bird level. In this lowered position, there is generally
no refill of the MalePan feed pans.
8. After that, the system is suspended again and filled for the next day.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 103

4.3.7.5 Adjusting the feed level

Pull at the brackets of the outer cylinder and adjust the desired feed level position. On
the left you'll find the uneven feed level positions and on the right you'll find the even
numbers.

According to experience, position 3 is the


optimal feed level adjustment which
should initially be chosen for the MalePan.

lowest feed level position largest feed level position

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 104 Operating Instructions

4.3.8 Vista 360

4.3.8.1 Features:

• automatic flooding mechanism: as long as the feed pan is standing in the litter and
the Augermatic tube is lowered to the outer cylinder of the feed pans, the pan is
flooded automatically (4.3.9 ”Automatic flooding mechanism”).
= high feed level, ideal for day-old chicks.

• the pan can be flooded in standing position


= high feed level; easily accessible for day-old chicks

• From this pan, only one version is available without grille


= feed is easily accessible for all birds

= day-old chicks can easily get in and out of the feed pan.

• smooth shape of the rim


= prevents injuries in the final grow-out period.

• baffles rotate with the outer cylinder


= prevents feed wastage

= for easy and thorough cleaning

• in suspended position, the pan is not flooded


= low feed level

= always fresh feed in the pan

= no feed wastage

• The broiler pan Vista not only satisfies the needs of day-old chicks but also those
of heavy birds in the final grow-out phase.
• As the birds grow, the entire feed line is raised which causes the flooding
mechanism to close thus decreasing the feed level inside the pan. This reduces
feed wastage (4.3.9 ”Automatic flooding mechanism”).
• Baffles at the pan rim additionally prevent feed wastage as they keep the birds from
pushing feed out of the pan.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 105

4.3.8.2 Adjusting the feed level

On the top side of the rim you'll find the numbers 0-6. These are required
for the adjustment of the different feed level positions. The arrow on the
rim must be adjusted centrally to the arrow on the cylinder outer.

According to experience, position 2 is the optimal feed level adjustment which should initially
be chosen for the Vista 360.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 106 Operating Instructions

4.3.9 Automatic flooding mechanism

In case of young birds (approx. day 1-3) the automatic flooding mechanism of the feed
pan should be activated. For this, the feed line is lowered until the tube of the
Augermatic (pos. 1) is placed directly on the outer cylinder of the pan (pos. 2). Now the
pan is completely filled and switched off by the sensor. Feed is easily accessible for the
young animals. In order to avoid high feed wastage, it is important that feeding is only
activated once a day.

Figure 4-6: Activate the automatic flooding mechanism (example: feed pan Vista)

After some days, the feed wastage may be too big since the birds can now better reach
the pan. Now the automatic flooding mechanism can be switched off by lifting the feed
line until the feed pan hangs minimally above the floor. Then only the lower part of the
pan is filled with feed. The feeding can now completely be controlled by the sensors
of the control pan. A deactivation is no longer necessary.

Figure 4-7: deactivate automatic flooding mechanism (example: feed pan Vista)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 107

4.4 Cable winch 350 kg GS for wall mounting incl. hand crank
(99-50-3099)

This type of winch has been tested in accordance with the requirements of the following
regulations: VBG 8 DA (winches, hoisting and hauling devices) and DIN EN 13157
(Cranes - Safety - Hand powered cranes)

Risk of injury
In the event of improper use the cable winch may cause serious
injury.
• You must read the following instructions carefully.
Danger • Never use a motor to operate the winch. It is designed
exclusively for manual operation.

4.4.1 Technical data

based on the first layer of the coiled cable on


544 kg (1200 lbs)
Nominal the winch:
capacity based on the outermost layer of the coiled
172 kg (379 lbs)
cable on the winch:
Gear ratio: 4.1 : 1
Reel diameter: Ø 33 mm
Holding capacity of the reel:  Ø 4.76 mm x 1600 mm
Cable diameter x cable length: (3/16“ x 55 ft)
183 mm x 272 mm x 150
Dimensions (L x W x H):
mm
Length: 206 mm
Handle
Required manual force: 13.5 kg
Net weight: 3.5 kg

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 108 Operating Instructions

4.4.2 Selecting and fastening the cable

1. Select a cable which can absorb 5 times as much as tractive force as admissible
at the cable winch (safety factor = 5).
2. Observe norm ISO 4308 when selecting the cable (cranes and lifting appliances;
selection of wire ropes)
3. Fix the cable(s) to the cable winch.
The following graphics show how to fix the cable(s) depending on the mounting position
of the winch.
If one cable is used: Guide the cable from the inside through a large hole and then
through the ends of the cable clamps. Lock the cable clamp by tightening the nuts.
If two cables are used: Fix the cable by threading the end through the cable screw
and tightening the nut.

Figure 4-8: Cable fixing for one cable

4. Guide the cable straight to


the winch. If it is guided e.
g. over an angle, the cable
can become severely
worn:
„Danger of accidents!“.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 109

4.4.3 Operation

1. Tighten all nuts before using the winch.


2. Oil all shafts and gear wheels before operating it for the first time.
3. Carry out a static test on the winch. Load the winch for 10 minutes with a load 1.5x
greater than the nominal load.
4. Turning the hand crank clockwise raises the load. Turning it anti-clockwise lowers
it.
5. Turning the hand crank clockwise and thereby raising the load causes the ratchet
to make a clicking noise as it engages. It does not make a clicking noise when
lowering.
6. To lock the load in position on the winch, turn the hand crank slowly clockwise until
you hear two “clicks”. Then slowly release the crank. You can lock the load in any
position you want.

Risk of injury
Improper use the cable winch may result in serious injuries.
• Never exceed the nominal capacity of the winch. This is based on
the first layer of the coiled cable on the winch (chapter ) and
Danger decreases with the increasing number of layers on the winch. The
nominal capacity of the outermost layer is less than 172 kg.
• Do not load the winch when the
cable is fully unwound. Keep at
least three full turns of cable
on the winch!
• Only ever operate the winch by
hand! This winch should not be
operated with a motor of any kind. If the winch cannot be
operated easily by hand, it has probably been overloaded.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 110 Operating Instructions

4.5 Sensor

4.5.1 Sensor DOL 26

4.5.1.1 Information concerning the sensor

DOL 26 is a capacitive sensor for detection of loose and solid materials. Start delay and
sensitivity are set by small potentiometers.

Figure 4-9: Sensor DOL 26

The sensor is available in following design:


• Code No. 60-40-5107 Sensor DOL 26 capacitive 20-280V AC/DC 2-wire sensitivity
and delay adjustable
The feed sensor DOL 26 has the following features:
• Protection class IP 69K can resist short contacts with high-pressure cleaners
• Time delay infinitely variable
• Adjustable sensitivity

4.5.1.2 Electrical connection of DOL 26

The sensor is connected in series with the load. The polarity is not important.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 111

4.5.1.3 Technical data DOL 26

Value
Code number 60-40-5107
Power supply 20-280 V AC/DC
Frequency 47 to 63 Hz
Min. inrush current (Im) < 10 (Ue = 20-90)mA RMS / mA
DC
< 6 (Ue = 90-280)mA RMS / mA
DC
Breaking current (lr) < 3 (Ue = 20-90)mA RMS / mA DC
< 1 (Ue = 90-280)mA RMS / mA
DC
Related operating current (le) 500 mA
Voltage drop/Ud) <6 V RMS
Detection speed <15 Hz
Start delay adjustable 5 - 60 seconds
Switching distance adjustable 0 - 12 mm
Switching hysteresis <1.2 mm
Ambient temperature in operation -20 to +70°C
Storage temperature -40 to +80°C
Cable length 200 cm
Line 2 x 0.5 (2 x AWG20) mm
Weight + 170 g
Protection class IP 69K; NEMA 1,3,4,6,12,13
Certification CE, UL and C-UL

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 112 Operating Instructions

4.5.1.4 Functioning of the sensor DOL 26

The light diode (LED) shows the current status of the sensor:

LED status Function


LED off Relay switched off
Led flashes slowly red Set delay time has nearly elapsed
LED flashes briefly red 2 Sensor error (overload protection activate)
x
LED on Relay switched on

4.5.1.5 Setting the time delay and sensitivity at the sensor DOL 26

Figure 4-10: Configuring settings at the sensor DOL 26

Pos. Description
1 Light-emitting diode (LED)
2 Potentiometer for the adjustment of the sensitivity (0 mm to 12 mm)
3 Potentiometer for the adjustment of the delay time (5 s to 60 s)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 113

4.5.2 Sensor DOL 44RG

4.5.2.1 Information concerning the sensor

The capacitive sensor is used as full/empty or filling level indicator. Start delay and
sensitivity are adjusted via small potentiometers. DOL 44RG is equipped with a
variable start delay of 0-300 seconds and and adjustable sensitivity.

Figure 4-11: Sensor DOL 44RG

The sensor is available in two versions for different voltages:


• Code no. 60-40-0625 Sensor DOL 44RG 10-30V AC/DC threaded, sensitivity &
start delay adjustable
• Code no. 60-40-0626 Sensor DOL 44RG 90-265V AC/DC threaded, sensitivity &
start delay adjustable
The DOL 44RG feed sensor has the following features:
• Protection class IP 69K can resist short contacts with high-pressure cleaners.
• No programming required = very easy handling
• Improved electronic compatibility due to improved immunity from disturbances in
power supply.
• Sensitive only at the sensor head and not in the area of the thread, thus no
unintended reaction due to feed on the thread.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 114 Operating Instructions

4.5.2.2 Electrical connection of the DOL 44RG sensor

The relay switches are galvanically isolated from the supply voltage.

Supply voltage 24 V AC/DC


Blue = - (0V)
Brown = + (24V)
Black 1 = COM
Black 2 = NC
Black 3 = NO

Supply voltage 230 V AC


Blue = - N
Brown = L (230 V)
Black 1 = COM
Black 2 = NC
Black 3 = NO

Important!
When mains voltage is available and the relays are activated, the internal relay
switches to COM - NC (1-4).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 115

4.5.2.3 Technical data DOL 44RG

Value (230 V) Value (24 V)


Code number 60-40-0626 60-40-0625
Power supply 90-265 V AC 10-30 V (AC/DC)
Frequency 47 to 63 Hz 47 to 67 Hz
Ambient temperature in operation -20 to +64 °C (-4 to +158 °F)
Storage temperature -30 to +80 °C (-22 to +176 °F)
Protection class IP 69K; NEMA 1,3,4,6,12,13
Certified standards UL; C-UL;CE
Length 110 mm
Diameter / Thread 30 mm
Weight 290 g
Start delay adjustable 0 - 300 seconds
Min. relay current 12VDC 100 mA
Switching distance adjustable 1 - 12 mm
Max. switching voltage relay 250 V AC
Max. inductive relay load 2A
Max. ohmic relay load 5A
Cable length 3000 mm
Wire dimensions 5 x 0.5 mm² / 5 x AWG20

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 116 Operating Instructions

4.5.2.4 Functioning of the sensor DOL 44RG

The motor of the AM drive is controlled by the sensor DOL 44RG with an adjustable
time delay of 0-300 seconds.
When the feed reaches the head of the sensor DOL 44RG in the control pan, the motor
of AM drive is turned off automatically.
When the feed level drops and the sensor DOL 44RG is no longer touched by the feed,
the motor of the AM drive is turned on again, after a certain time-delay. As the feed level
constantly changes because of the feed consumption of the animals, the spiral would
have to be turned on and off frequently. To avoid this, the sensor DOL 44RG is
equipped with a time-delay mechanism.
The light diode (LED) shows the current status of the sensor:

LED status Function


LED off Relay switched off
LED flashes Relay switched off, adjusted time delay elapses
LED on Relay switched on

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 117

4.5.2.5 Setting the time delay and sensitivity at the sensor DOL 44RG

Figure 4-12: Configuring settings at the sensor DOL 44RG

Pos. Description
1 Light-emitting diode (LED)
2 Potentiometer for the adjustment of the sensitivity (1 mm of 12 mm)
3 Potentiometer for the adjustment of the delay time (0 s to 300 s)

The capacity of reaction of the sensor DOL 44RG is so great that the
varying moistness of the feed changes the switch time. For the
adjustment, the feed should be as dry as possible. The drier the feed, the
more secure the switching function of the sensor DOL 44RG.

If sensor DOL 44RG in the control pan does not interrupt the power supply of the AM
drive, the sensitivity has to be increased. If the sensor DOL 44RG in the control pan
does not react and the motor of the AM drive is not started, the sensitivity has to be
decreased.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 118 Operating Instructions

4.6 Dial-type crane scale

Mode of operation
The scale shuts the automatic outlet or stops the Flex-Vey drive as soon as the
adjusted feed amount has been filled into the suspended feed hopper.
(Please see also the manual „Flex-Vey“) The filling process is started manually or by
means of a timer.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Operating Instructions Page 119

1. Calibration of the scale

a) Fine calibration
• Set the needle of the scale to „0“
by means of the set screw
(Pos. 1).

b) Coarse calibration
• Loosen the sight glass locking
(Pos. 2).
• Dismount the fastening ring
(Pos. 3).
• Remove the sight glass (Pos. 4).
• Loosen the retaining screw for the
needle (Pos. 5). Set the needle
to„0“ and tighten the retaining
screw.
• Assemble the retaining ring
together with the sight glass.
• If necessary, carry out a fine
calibration (see subitem a).

2. Adjusting the desired feed quantity

• Loosen the sight glass locking


(Pos. 2).
• Turn the sight glass (Pos. 4) until
the arrow points at the desired
feed amount.
• Fix the sight glass locking.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 120 Maintenance

5 Maintenance
Ideally, the feed delivery date should be close to the moving-out date so that the silo,
the Flex Vey system, the Augermatic line and the feed pans are empty when you want
to stop the feeding.
If this is not possible, try to shut off the feed supply from the silo so early that the goal
described above is achieved by all parts of the silo's outlet system. Where this option
is not possible either, it may be necessary to remove the remaining feed by letting the
line run dry as soon as the feed supply is switched off.

5.1 Drive units

• Under normal conditions, there is no need for oil or grease change.


• Carry out the change of oil in accordance with the directions of the gear motor
manufacturer (see sticker at the gear motor). The lubricating grease for gear
motors type ESTA amounts to 90 grams for 0,37 kW or 280 grams for 0,75 kW
motors.
• In exceptional cases, e.g. after leakages, we recommend the following lubricants:

ARAL aral grease FDO


BP BP energrease HT-EP-00
CALYPSOL calypsol D 8024
ESSO esso fibrax EP 370
MOBILOIL mobilflex 46
SHELL shell special reductor grease H
shell grease S 3655
shell semnia grease-O
TEXACO glissando GF 1464
Table 5-1: Overview lubricants

• Prevent condensation and cleaning water from penetrating the inside of these
devices.
• Regularly clean the motors' cooling fins to prevent overheating.

5.1.1 Maintenance of the drive unit AM6

The drive AM 6 is maintenance-free.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 121

5.1.2 Oil level control AM5

All AM5 Augermatic drives have a ventilation opening on the gear unit. This ensures
that hot air can escape from the inside of the gear unit during operation.
The ventilation opening is located in the access shaft on the front side of the gear unit
and is closed during transport (Picture 1, Pos. 1).
Before putting the drive into operation, open the gear ventilation by pulling out
the plug (Picture 2, Pos. 1).

Picture 1: Ventilation closed Picture 2: Ventilation open

If the ventilation remains closed, leakage from the gear unit is likely.

Leaks may occur on the drive AM5 as a result of bleed plugs not being opened or of
spraying directly with high-pressure cleaner.
To prevent damage, a visual check of the Augermatic drive must thus be performed
regularly after each batch, however, every 6 weeks at the latest. If a leak is detected,
the drives' gearbox oil level must be checked.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 122 Maintenance

On the gearbox, there is a monitor screw


(detail A) which must be opened for
checking the oil level.
If the gearbox leaks oil or if the oil is right
beneath the lower edge of the hole, then
oil level is correct. Otherwise use oil of
specification SAE 85W-90 until it comes
out of the monitor hole.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 123

5.2 Auger HD AM

! Make sure that there are no bends in the auger!

5.2.1 Fastening of auger at the drive unit

If the auger must be fastened again to the drive, please observe the
following:

Turn the auger up to the guard plate


for drive shaft and clamp the auger by
means of the hooked bolt.

Figure 5-1: Mount the auger on the drive

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 124 Maintenance

5.2.2 Replace bearing at the tension shaft

1. Proceeding:
Loosen the U-bolt and pull the tension shaft carefully out of the lower part for feed
hopper.

Figure 5-2: Loosen U-bolt Figure 5-3: Pull out tension shaft
2. Proceeding:
Fix the auger in the lower part by means of a vise-grip wrench. Loosen the set
screw at the tension shaft and turn respectively pull the tension shaft out of the
auger.

Figure 5-4: Fix the auger by means of a Figure 5-5: Loosen the auger from the
vis-grip wrench tension shaft

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 125

3. Proceeding:
Replace the bearing at the tension shaft or replace the complete tension shaft.

4. Step
Twist or push the tension shaft into the auger and fix it by means of a threaded pin
(Figure figure 5-7).

Figure 5-6: Auger to tension shaft Figure 5-7: Fix auger


5. Step:
Remove the vise-grip wrench carefully while a fitter keeps the tension shaft.

Push the tension shaft into the lower part and fix it by means of an U-bolt.

Figure 5-8: Keep the tension shaft Figure 5-9: Fasten the tension shaft

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 126 Maintenance

5.2.3 Repair auger

Check the functioning of the conveying augers every day!

• If the auger must be repaired at the drive AM, the tube clamp between the last and
one but last tube (side of drive unit) is loosened and both tubes are pulled apart.
• The auger is now fixed between both tubes by using a vise-grip wrench.
• Loosen the auger at drive and carry out the repair.
• If the auger at the feed hopper must be repaired, please proceed in the same
way.

Figure 5-10: Repairing the auger

Pos. Qty. Code no. Description


1 Tube
2 11-31-3238 Auger HD AM
3 Tube clamp
4 Vise-grip wrench

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 127

5.2.4 Weld the auger HD AM

Avoid a too hot welding of the auger


Make sure that the welding device is correctly adjusted. Too hot welding
will change the material properties of the auger and thus increases the risk
for rupture.
The welding seam must not be cooled down abruptly with water or
other liquids.

Let the auger slowly cool down at the


air. A cooling with any liquids makes the
material of the auger brittle and thus
increases the risk of fracture!

– Selection of the welding filler metal


a) Gas metal arc welding
Welding wire: SG 2 Ø 0.8mm

Description according to EN ISO 14341-A: G 42 3 M G3Si1

b) Manual arc welding


Stick electrode 2.5 x 350 [mm]

Description according to EN ISO 2560-A: E 38 2 RB 12

– Procedure
• Step 1: Cleaning and degreasing of conveying auger
The ends of the auger must be thoroughly cleaned and degreased before the
welding process. For this purpose it is possible to use for example customary wash
dilution.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 128 Maintenance

• Step 2: Alignment of the conveying augers to be welded


Both ends of the auger must be aligned and fixed to each
other as an L- or U-profile. The fixation of the conveying
augers can be done by means of normal screw clamps.

The longer the profiles for the alignment, the more accurate the alignment
of the conveying augers to each other.

a) In order to prevent damage to


the tubes due to sharp edges,
the ends of the auger have to be
furnished with amply 45° bevels
and edges have to be removed.

b) Both ends of the augers must overlap 30mm. It is important that they are pushed
in front of each other and do not twist them together.

• Step 3: Preparation of a welding seam

a) Join both auger ends with an


internal welding seam with a
length of 20mm.

t= Height of the auger (in section)


b= Maximum depth of the welding seam (approx. 0.5 x t)

The distance of the welding seam must be 5


mm from both ends of the auger.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 129

! b)
The welding seam has to cool down for approx. 30 seconds after the
welding. An acceleration of the cooling-down process for example by
means of water is not allowed!

After the 20 mm welding seam has cooled


down, the ends of the auger have to be
welded to the respectively other auger by
means of an additional welding seam.
Explanation of symbols of the welding seam:

x= Material thickness e.g. Augermatic auger 3.85mm


b= 0.5 x height of the auger e.g. Augermatic auger 0.5 x 8 = 4[mm]

!
When the welder prepares the welding seam he has to start at point 1 and
move the welding device towards point 2.
It must be observed that point 2 is not heated for too long as this spot will
soften and consequently break during operation.

c) After both welding processes are carried out, there is no need for any rework e.g. with
an angle grinder. An edge which might have developed during the welding process
does not disturb the feed transport!
If the manual arc-welding procedure was applied, just remove the dross by tapping.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 130 Maintenance

5.3 Replace conveying tubes

Check all conveying tubes regarding bulges and deformations. Damaged conveying
tubes must not be mounted!

If you replace a conveying tube or an end tube, remove the feed pans and,
if necessary, the control pan as well. Fix them at the replaced tube. Make
sure that the pans are fastened in the same way.

5.3.1 Fixing the feed pans to the feed tubes

Standard:
1. „Swinging“ fastening of the feed pan BigPan 330, FLUXX 330, FLUXX
360, BigPan 2, MultiPan and Vista.
2. „Not swinging“ fastening of the feed pans MalePan and FLUXX
Breeder 360.
Option:
3. „not swinging“ fastening of the feed pans BigPan 330, BigPan 2,
MultiPan and Vista.
4. „not swinging“ fastening of the feed pans FLUXX330 or 360.
Additionally necessary: compression spring and holding bolts.
Conveying pipes BP are to be replaced by conveying pipes MalePan.
For the feed pans MalePan and FLUXX Breeder 360 a
„swinging“ fastening is not provided!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 131

Fastening types for the pans at the conveying tube

Standard:
1. swinging: pan can swing freely in the conveying tube.
2. not swinging: pan is kept in the conveying tube by means of a compression spring and
holding bolt.
1.swinging 2.not swinging

Option:
3. not swinging: the pan is suspended at the conveying tube with the inner cylinder
4. not swinging: the pan is kept in the conveying tube by means of a compression spring
and holding bolt
5. not swinging 6. not swinging

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 132 Maintenance

BigPan 330:

Fasten the feed pan with


the tube adapter to the
conveying tube (please also
observe 5.3.1 ”Fixing the
feed pans to the feed
tubes”).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 133

FLUXX 330:

Fasten the feed pan with the tube adapter on the conveying tube (see also ).

FLUXX 360:

Fasten the fed pan with the tube adapter on the conveying pipe (see also ).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 134 Maintenance

BigPan 2:

Fasten the feed pan with the tube adapter on the conveying tube (please also observe ).

MultiPan 330:

Fasten the feed pan with the tube adapter on the conveying tube (please also observe ).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 135

FLUXX Breeder 360:

Put the tube on the cylinder inner


Put the holding pin for tube adapter and the compression spring in the tube adapter.
Press the tube adapter on the tube together with the holding pin and the compression spring
and push the tube adapter on the cylinder inner.
The holding pin must lock into the boring of the tube. (Please also observe chapter )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 136 Maintenance

MalePan:

Put the tube on the cylinder inner


Insert the holding pin for tube adapter and the compression spring in the tube adapter.
Press the tube adapter on the tube together with the holding pin and the compression spring
and push the tube adapter onto the cylinder inner.
The holding pin must lock into the boring of the tube. (Please also observe chapter )

Vista 360:

Fasten the feed pan


with the tube adapter on
the conveying tube
(please observe
chapter ).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 137

5.3.2 Join the conveying tubes

The connecting sleeves are always directed towards the feed


hopper!

• Push a conveying tube with the smooth end to the limit stop of the connecting
sleeve of the following conveying pipe. The slot of the connecting sleeve must
show upwards.
• Mount the tube clamps that way that a distance of approx. 10mm is left to the end
of the tube.

Pos. Qty. Code no. Description


1 Conveying pipe
2 End tube
3 11-31-3211 Tube clamp riveted cpl for tube d45.0
X Direction of feed hopper

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 138 Maintenance

5.3.3 Shorten the feed line

!
If the feed line has to be shortened, this may only be carried out at the last
conveying tube in front of the feed hopper.
Please observe the following:
• The tube may only be shortened at the straight end, the sleeve must
remain.
• The conveying tube may be shortened maximally 100mm in front of
the last feed pan.
• Keep a minimum distance of 100mm to each feed pan.

Minimum length of the conveying tube Distance between cut and feed pans
(after the shortening)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 139

5.3.4 Position of the control pan at the end tube

Always mount the control pan as last but one pan in front of the drive.
End tubes must not be shortened!
Initially, the control pans are mounted to the end tubes without sensor.

Pos. Qty. Code no. Description


1 End tube
2 Feed pan
3 Control pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 140 Maintenance

5.4 Cable winch 350 kg GS for wall mounting incl. hand crank
(99-50-3099)

1. Lubricate the gear wheels, roller shaft and handle thread regularly to ensure they
function smoothly and guarantee the long service life of the winch.
2. Lubricate the winch as described above if it has been stood idle for a long period.
3. Keep all moving parts of the winch (gear wheels, ratchet mechanism, drive shafts
etc.) clean and lubricate them regularly to ensure the safe and reliable operation of
the winch.
4. Check the winch regularly for wear. To be able to see the brake disks (9 and 11)
and the ratchet (10 / 21), etc., remove the hand crank (26) and the protective cover
(14).
The brake discs must be replaced if they have been worn down by approx. 1.5 mm.
If the discs show any signs of cracks, they must be replaced immediately.

Risk of injury
In the event of improper use the cable winch may cause serious
injury.
• Never operate the winch if the cable is knotted or twisted, or if it
Danger is not properly secured!
• Ensure that no-one is located in the vicinity of the winch when it
is under load and/or is being operated.
• Only maintain and clean the winch when it is not under load.
• When replacing faulty parts, ensure they are positioned and
assembled correctly.
• Inspect the winch for corrosion and replace any faulty parts
before operating the winch.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Maintenance Page 141

Risk of injury
In the event of improper use the cable winch may cause serious
injury.
• The winch is only intended to be used for conveying and hoisting
Danger operations. Do not lift, secure or transport people or convey loads
over operational areas where people are located.
• Never oil the winch brake discs!
• Always avoid overloading the winch!
• Do not exceed the maximum tractive force specified for the cable.
• Do not intentionally knot the cable.
• Ensure that the winch is only operated by competent individuals.
Keep children and individuals unfamiliar with the operation of the
winch away from it.
• Ensure that the load to be hoisted by the winch is secured safely
and evenly.
• Always keep the winch in good condition.
• Never use the winch if it is damaged.

Risk of injury
Fingers, loose clothing and body parts may be drawn into the winch
by gear wheels, etc.

Danger • Keep a suitable distance from the winch’s moving parts.


• Wear close-fitting protective work clothing.
• Never work with long hair that has not been tied up.
• Never wear any rings, necklaces, watches, scarves, ties or
other such items.
• Keep a suitable distance and wear protective gloves if necessary.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 142 Hygiene, health and safety, cleaning and disinfection

6 Hygiene, health and safety, cleaning and disinfection


There are different measures for cleaning and disinfection which guarantee optimum
hygiene on the farm.
All these measures have the following objective:
1. Reduction and removal of contaminations
2. Prevention of diseases
3. Creation of optimum performance conditions for the birds
Since the conditions are very different on each farm, the following explanations serve
as guideline for the above mentioned objectives.

6.1 Hygiene measures for maintaining a high hygiene level

Maintaining a high hygiene level on the farm is an important factor in poultry


management. Remember that poultry houses cannot be sterile. It is therefore important
to reduce the number of pathogenic germs and to prevent their multiplication. In order
to guarantee a hygienic farm, Big Dutchman recommends observing the following
measures:
• The farm staff is not allowed to have contact to birds or other poultry outside of the
farm!
• All vehicles must be disinfected before entering the farm. Install sprinkler hoses as
well as disinfection tubs for tyres at a place outside of the farm!
• The farm should be fenced! The gate should only be opened when required.
• No other poultry and birds may be on the farm!
Farms should always be safeguarded against invasion of wild birds, if possible!
The buildings themselves must be protected against the invasion of birds of any
kind (even the smallest oscine birds). This can be realised e.g. by installing bird
screens in front of the ventilation openings.

• There should be no rodents on the farm! Draw up a plan for pest control and
implement it!
• Eliminate weed on the farm premises!
• No feed should left open anywhere on the farm! Store feed in a dry place and keep
it out of reach of animals!
• Hand disinfectants as well as disinfecting mats have to be available in every
service room!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Hygiene, health and safety, cleaning and disinfection Page 143

• All hygiene provisions should be complied with not only during the batch but also
during the entire service period!
• Keep the number of unnecessary visitors on the farm as low as possible. When
entering the farm / building, all visitors should wear protective clothing and enter
their name into the visitor book!
The farm should have a hygiene sluice for changing clothes and prevent a
spreading of germs! This sluice must be constructed according to the black/white
principle.

The "black" outdoor area which is regarded as potentially contaminated with


pathogenic germs shall be separated from the "white" inside area of the house
which is less contaminated so that a transmission of germs is hindered or
prevented.

Persons must take all their clothes off in a "black" dressing room in front of the
passage to the building; after having passed a shower, they will then reach another
"white" room where they can put on their work clothes / protective clothes. When
leaving the house, all these actions have to be taken in reverse order. All persons
entering or leaving the house have to pass through this hygiene sluice!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 144 Hygiene, health and safety, cleaning and disinfection

6.2 Staff health and safety

Big Dutchman would like to remind you that for all methods used on the farm, including
the hygiene program, the safety and well-being of your staff should always be carefully
considered. For most countries, there are laws and or/provisions which should be
complied with.
Do not forget to provide your staff with protective equipment required for the correct
carrying out of their tasks.
The protective equipment includes:
• protective clothing
• safety shoes
• protective mask, if necessary
• eye protection
• nose and mouth mask
• gloves
Be very careful when using disinfectants, especially gaseous agents, since many
agents available on the market may be harmful for the staff.

Shut off the power when cleaning live parts!


Protect moisture-sensitive components like control cabinets and motors
from splash water during wet cleaning by covering them!

Water in combination with dust and feed remains can lead to slippery
floors!

Cleaning agents and disinfectants can cause corrosion! Observe the


manufacturer's instructions!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Hygiene, health and safety, cleaning and disinfection Page 145

6.3 Cleaning and disinfection

6.3.1 Comparison between wet and dry cleaning

The system may either be wet-cleaned or dry-cleaned. Wet cleaning allows for a more
effective disinfecting process.
The system must be ventilated dry immediately after a wet cleaning. If the system is
not dried and is damp for a very long time, rust may form and can damage the
components.
Dry cleaning is the best option regarding a long service life of your system, but it may
not be the right method for you. We learned from different customers worldwide that dry
cleaning alone is not able to sufficiently reduce the number of germs, thus causing
more diseases in the birds and in turn reducing the animal performance.
Wet cleaning removes biological substances and germs more efficiently from the
system than dry cleaning.
If your program includes the use of disinfectants, you should also consider that
biological substances might protect the germs.
Young birds with low immune systems are exposed to germs which originate from the
last herd and which were not eliminated during the cleaning process. Big Dutchman
recommends discussing the details with your veterinarian.

6.3.2 Service life of equipment

!
Important
If the house is disinfected thermally, please consider that the temperature
must not exceed 60°C.
Temperatures above 60°C can cause damage to the house equipment. In
particular, there is a risk that the plastic parts deform.

Big Dutchman uses the best corrosion-free steel grades available on the market. In
some models, specific parts, especially in critical areas of the system, are made of
Galfan steel which provides the highest protection possible.
Still, it is common knowledge that some methods influence the product's service life
negatively, independent of the quality of the corrosion protection and the supplier of the
equipment. These unfavourable methods include:
(a) wet cleaning of the components if they are not immediately dried afterwards;

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 146 Hygiene, health and safety, cleaning and disinfection

(b) high-pressure cleaning which may be more aggressive than normal cleaning,
depending on the equipment and the duration of the cleaning process;
(c) use of disinfectants which can damage steel or plastics and shorten the service life
if they are used in high concentrations or longer than necessary.
These notes also refer to the building if this is made of coated steel.

!
Important
When choosing the disinfectant, you must pay attention to the corrosion
resistance.
Especially the disinfectants on acid basis tend to dissolve the zinc coat of
galvanized components.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Hygiene, health and safety, cleaning and disinfection Page 147

6.3.3 Carrying out cleaning and disinfection

Cleaning must be carried out in a way that the surface structure, colour and original
condition are clearly visible in every case.

6.3.3.1 Basic procedure

Primary Soaking Cleaning Rinsing and Disinfection Drying


cleaning, then according to (immediately
combating of immediately the manu- after
rodents and drying facturer’s completed
applying instructions. If disinfection
insecticides prescribed: procedure)
rinse

6.3.3.2 Before cleaning

• In order to guarantee a quick and thorough cleaning by means of a high-pressure


cleaner, the feeding system must be brought to an optimal working height with a
winch system.
The feed pans as well as the entire feeding system are so stable that a cleaning
with a high-pressure cleaner is possible without causing any damages.

Regarding the height adjustment of the feed line see also chapter

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 148 Hygiene, health and safety, cleaning and disinfection

6.3.3.3 Primary cleaning, combating of rodents and applying insecticides

1. Remove all remaining feed as well as litter rests and manure from the system!

Important:
The feed conveying tubes must be completely empty before cleaning the
house with water!
Rests can harden through the moisture. They are also a hygienic risk.

2. Remove the dust from all equipment pieces and all places below the coverings!
3. Treat walls and ceilings with insecticides while the house is still warm.
• A thorough cleaning and disinfection does not have any success if germs are
distributed by flys over the freshly disinfected surfaces.
4. Kill off rodents (mice, rats) and arthropodes which can transmit and distribute
germs of animal diseases!
5. All equipment which can be removed from the house should be taken outside.

6.3.3.4 Soaking

1. Only if possible: To make sure that the surfaces do not dry early during the
following soaking procedure, both ventilation and heating should be switched off
before starting with the soaking.
2. Soak the interior of the building, walls, ceilings and the residual equipment approx.
10 hours before the wet cleaning. Use fat- and protein-dissolving products.
• During soaking make sure that sufficient liquid arrives on the dirt in order to
dissolve the dried dirt layer.
3. Avoid a re-drying of the dirt until the wet cleaning is started.

Thorough soaking can reduce the duration of the following cleaning


period considerably.

6.3.3.5 Wet cleaning

For the wet cleaning, the pans should remain closed during the cleaning process so
that they can swing under the pressure of the water jet. After the high-pressure
cleaning, the pans should be opened so that the water can drain off.
1. Clean the house with pressure washers, starting with the ceiling and working down
to the floor, paying particular attention to ventilation elements, pipelines, edges and
top surfaces of beams.
Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Hygiene, health and safety, cleaning and disinfection Page 149

2. Make sure the house is well lit during the cleaning operation so that dirt is clearly
visible.
3. Dirty drinkers and water tanks are potential hazards and should therefore be
cleaned and disinfected (see also chapter 6.3.3.7 ”Disinfection”).
4. Any furniture taken outside and the exterior of the building, including outdoor
concreted areas, should also be washed down.
5. Keep in mind that some parts of the system and building must not be cleaned with
water, as e.g. electrical motors, electrical control panels as well as everything that
could be damaged by water.
6. The Big Dutchman motors are designed for gentle cleaning, however not for high-
pressure cleaning.

The cleaning process has been successfully finished when all


cleaned parts are visually clean and the drained off water is free from
dirt particles.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 150 Hygiene, health and safety, cleaning and disinfection

6.3.3.6 Rinsing and drying

1. After washing it is advisable to rinse the surfaces and equipment with clean water
to remove residues of cleaning agents.
2. Rinse the house starting with the ceiling and working down to the floor.
3. Ventilate the house thoroughly after having completed the cleaning so that it can
dry quickly.
• Remove water accumulations which cannot dry fast enough by hand!
4. Oil all the chain wheels, roller chains and rust-sensitive parts again.
5. After cleaning, carry out necessary repair and maintenance works.

A thorough and careful house cleaning is an imperative precondition


for a successful house disinfection!

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Hygiene, health and safety, cleaning and disinfection Page 151

6.3.3.7 Disinfection

Many hygiene programs all over the world demand the use of disinfectants after the
cleaning process. You should however keep in mind that many disinfectants may
reduce the service life of your installation.
For the choice of the correct disinfectant, please observe the following:
• Could the disinfectant endanger the health of persons?
– Take all necessary measures (e.g. protective clothing, gloves and respiratory
equipment, etc.) to exclude any dangers for the persons handling the
disinfectants!
• Which infectious agents can be combated with it?
– In case of doubt please contact your veterinarian.
• For which temperature range is the disinfectant provided?
– If the disinfectant is used at temperatures other than those specified, the
efficacy of the agent will be reduced.
• Is the disinfectant appropriate for the treatment of galvanized steel?
– Unsuitable disinfectants can lead to corrosion of the steel and destroy it!
• Is the disinfectant appropriate for the treatment of plastics?
– Unsuitable disinfectants can destroy plastics!
• Is the disinfectant appropriate for the treatment of other materials existing in
your house?
– Unsuitable disinfectants can destroy these materials.

The instruction leaflet and/or packing or the safety data sheet of the
manufacturer will provide you with information regarding the
protection of persons handling the disinfectant and regarding the
resistance of various materials to the disinfectant.

In any case, you should weigh up the advantages and disadvantages for each single
component of your system when you decide to use a disinfectant.
Please also consider its involvement in the entire process of your hygiene program.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 152 Hygiene, health and safety, cleaning and disinfection

Disinfection procedure:

!
Important
If the house is disinfected thermally, please consider that the temperature
must not exceed 60°C.
Temperatures above 60°C can cause damage to the house equipment. In
particular, there is a risk that the plastic parts deform.

An equipment like the Augermatic feed line is normally installed in a nearly airtight
building. This allows the use of gaseous substances which eliminate germs. This is a
method quite common in some parts of the world.
Below you will find a description of a wet disinfection:
1. Please consider and observe the usage recommendations of the manufacturer
regarding concentration, soaking time, admissible ambient temperature,
temperature of the components to be disinfected and quantity of the disinfectant
solution!
2. Take all measures (e.g. protective clothing, gloves and respiratory equipment, etc.)
to exclude any dangers for the persons handling the disinfectants!
3. Important: Never mix several disinfectants since the single active agents can
cancel each other and moreover new explosive connections could form.
4. The surfaces and objects to be disinfected must be clean and dry!
• Residual moisture or puddles in the house can lead to a dilution of the
disinfectant and thus to a reduction of the efficacy. Consequently, more
disinfectants must be applied in order to achieve an optimal result.
5. The disinfectant is applied starting in the back of the house and working to the front
respectively starting with the ceiling and working down to the floor.
6. When applying the disinfectant make sure that the surfaces are completely
moistened.
• This working solution should be applied with max. 10 to 12 bar working
pressure and reduced conveying capacity since otherwise aerosols will
develop and the wetting properties change.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Hygiene, health and safety, cleaning and disinfection Page 153

7. During the soaking time, the ventilation system should be switched off if possible
in order to avoid that the surfaces dry up too fast.
• The treated houses may only be entered with a respirator mask for a
certain time, depending on the method of applying, soaking time and
active agent.
8. The disinfected surfaces and objects should be rinsed thoroughly if the
specifications of the disinfectant manufacturer demand this.

!
Important
The feeding and drinker systems however must always be rinsed
thoroughly after the disinfection.
Drinker lines must always be rinsed on the inside after completed
disinfection. In case the soaking time is too long, the drinking nipples may
become leaky. Chlorous disinfectants are to be regarded as especially
critically in this connection.
All residues of the disinfectant should therefore be removed.

Checking the disinfection results:


Appropriate steps should be taken to check the efficiency of the disinfection.
1. Take adhesive film tests and swab samples of housing equipment and surfaces!
• The total number of germs / cm² is determined with these tests. It should be
below 1000 CFU (= colony forming units).

If the germ presence is determined to be too high following cleaning and


disinfection, the above measures are to be repeated and the moving a
new batch in is to be postponed.

6.3.3.8 Drying after a complete and successful wet disinfection procedure

The system must be ventilated dry immediately after a complete and successful wet
disinfection procedure.
If the system is not dried and is damp for a very long time, rust can form and thus
damage the components.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 154 Troubles and their remedies

7 Troubles and their remedies

7.1 Hooked bolt M 6x35 broken

• Foreign matter in the tube outlet


=> Tap the tube until you find the place where it is empty. Look for foreign matter.
Reduce auger tension. Turn back auger at the motor. Remove foreign matter.

• Congestion, obstruction in the auger


=> Localize the place where the tube is empty. Dismount the tube at that place and
remove the congestion.

• Auger broken
=> Remove the auger and repair it.

7.2 Warm place in the tube or hole picked in the tube

• Kink in the auger


=> Remove approx. 3m of auger and insert a new piece of auger by welding. (See
chapter ).

• Jam in the auger


=> Locate the place where the tube is empty or warm. Disassemble the tube and
remove jamming.

• Auger wrongly welded


=> If necessary, cut in two the auger, remove the deformed piece and weld again
(see chapter ).

• Auger bent at wear point


=> Replace respective piece of tube and of auger (see chapter ).

• Auger "climbs up" at the drive AM.


=> Auger too long. Shorten the auger (see chapter ).

=> Auger bent. Check the auger regarding deformations and repair it (see chapter
).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Troubles and their remedies Page 155

7.3 The entire feed line does not start

• No or too low supply voltage.


=> Replace the defective fuse.

=> Check whether thermal protection is correctly adjusted. Normally, the thermal
protection switches off the motor in case of too high intensity of current.

=> Check electric mains to the house for correct tension.

• Sensor does not switch.


=> Control fuse in switch box faulty.

• Time switch or time switch motor faulty.


=> Replace damaged time switch or motor of time switch.

• Delicacy of sensor is too high.


=> Reduce the delicacity (see also chapter )

7.4 Protective motor switch regularly switches off the motor

• Oil film on auger and inside of tube causes increased charge on motor upon first
putting into operation of Augermatic.
=> Remove oil film. Fill the system with so much feed that all feed pans are filled.

• Insufficient power supply to motor.


=> Check clamped tension at motor and compare with rating plate.

=> Check whether the cross section of the connecting cable is too small.

=> Check whether the motor 380V has to be connected to 3 phases, but is only
supplied by 2 phases.

• Foreign matter in auger. Motor starts, then stands still and the auger moves in the
opposite direction.
=> Check the feed hopper, control pan and feed outlets for foreign matters.
Remove them.

7.5 Auger operates irregularly

• Bearing or tension shaft is stuck or damaged.


=> Replace the bearing (see chapter ).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 156 Troubles and their remedies

• Insufficient auger tension.


=> Shorten auger (see chapter ).

• Foreign matter in auger


=> Remove foreign matter.

• Too strong tension on auger.


=> Lengthen auger at feed hopper (see chapter ).

• Auger is detached from tension shaft.


=> Check whether the tension shaft is fixed correctly (see chapter ).

7.6 Bearing of tension shaft is stuck or damaged.

• Cleaning water in the lower part for feed hopper.


=> Remove water.

=> Replace the bearing, if necessary (see chapter ).

7.7 Tube kink in the tube outlet holes

• Outlet holes not correctly made.


Replace tube (see chapter ).

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Troubles and their remedies Page 157

7.8 Augermatic does not switch off

• No feed in feed hopper.


=> Check supply systems and remove possible mistakes.

• Auger broken.
=> Repair auger (see chapter )

• Delicacy of sensor is not sufficient.


=> Enlarge delicacy of sensor (see chapter ).

7.9 Auger causes an excessive noise

• No feed in feed hopper.


=> Check silo filling. Repair supply systems, if necessary.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 158 Spare parts

8 Spare parts

Operational safety is the prime necessity!


For your own safety only use original Big Dutchman spare parts. For
foreign products that have not been released or recommended or for
modifications carried out (e.g. software, control units) we cannot judge
whether there is a safety risk in connection with the Big Dutchman
systems.

Indicate the following for ordering spare parts:


• Code no. and description of the spare part or
• Invoice no. of original invoice
• Current supply, e.g. 230/380 V 50/60 Hz

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 159

8.1 Conveying tubes

8.1.1 Tube 45x1.25-3050 2-4 hole

Pos. Code no. Description


1 11-31-3522 Tube 45x1.25-3050 2hole BP330
2 11-31-3523 Tube 45x1.25-3050 3hole BP330
3 11-31-3524 Tube 45x1.25-3050 4hole BP330

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 160 Spare parts

8.1.2 Tube 45x1,25x3050 MalePan (for MalePan and FLUXX Breeder 360)

Pos. Code no. Description


1 11-03-3721 Tube 45x1.25-3050 1hole Male-Pan
2 11-03-3722 Tube 45x1.25-3050 2hole Male-Pan
3 11-03-3723 Tube 45x1.25-3050 3hole Male-Pan
4 11-03-3724 Tube 45x1.25-3050 4hole Male-Pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 161

8.1.3 End tubes

! The end tubes must not be shortened.


Make sure that the sticker (00-00-1119) is applied on each end tube.

If the conveying tubes are used: 8.1.1 ”Tube 45x1.25-3050 2-4 hole”

If the following conveying tubes are used: 8.1.2 ”Tube 45x1,25x3050 MalePan (for
MalePan and FLUXX Breeder 360)”

Pos. Code no. Description


1 11-31-3529 End tube 2775mm 4hole dia45 BP330
2 11-03-3729 End tube 2775mm 3hole dia45.0 Male-Pan
3 00-00-1119 Sticker D/GB/F: End pipe for control pan

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 162 Spare parts

8.2 Feed pans and control pans

8.2.1 Big Pan 330 single components [feed pans]

[11-31-3501] Feed pan cpl BigPan 330 wo/shut-off

Pos. Code no. Description Graphics


1 11-31-3511 Dish BP330
2 11-31-3512 Grille BP330
Cylinder inner for BP/MP330
3 11-31-3513
wo/shut-off
Cylinder outer for BP/MP/
4 11-31-3514
RPM330/MalePan
5 11-31-3515 Tube adapter for BP/MP330
is not part of the feed pan
6 Tube 45x1.25-3050 BP330
Auger open core 35.4/45 right
7 11-31-3248
AM/SA per running meter (=> )
optionally available:
Volume reducing insert white
8 11-31-3568
MP/RPM330

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 163

[11-31-3530] Feed pan cpl BP330 with shut-off

Pos. Code no. Description Graphics


1 11-31-3511 Dish BP330
2 11-31-3512 Grille BP330
Cylinder outer for BP/MP/
3 11-31-3514
RPM330/MalePan
4 11-31-3536 Slide shut-off BP/MP330
5 11-31-3515 Tube adapter for BP/MP330
Cylinder inner for BP/MP330
6 11-31-3533
with shut-off
Guide ring for shut-off BP/
7 11-31-3537
MP330
is not part of the feed pan cpl:
8 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
9 11-31-3248
AM/SA per running meter (=> )
optionally available:
Volume reducing insert white
10 11-31-3568
MP/RPM330

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 164 Spare parts

[11-31-3701] Feed pan cpl BP330-Plus wo/shut-off

Pos. Code no. Description Graphics


1 11-31-3512 Grille BP330
Cylinder inner for BP/MP330
2 11-31-3513
wo/shut-off
Cylinder outer for BP/MP/
3 11-31-3514
RPM330/MalePan
4 11-31-3711 Dish RPM330
Volume reducing insert orange
5 11-31-3518
BP330-Plus
6 11-31-3515 Tube adapter for BP/MP330
is not part of the feed pan cpl:
End tube 2775mm 4hole dia45
7 11-31-3529
BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 165

[11-31-3730] Feed pan cpl BP330-Plus with shut-off

Pos. Code no. Description Graphics


1 11-31-3512 Grille BP330
Cylinder outer for BP/MP/
2 11-31-3514
RPM330/MalePan
3 11-31-3536 Slide shut-off BP/MP330
4 11-31-3711 Dish RPM330
Volume reducing insert orange
5 11-31-3518
BP330-Plus
6 11-31-3515 Tube adapter for BP/MP330
Cylinder inner for BP/MP330
7 11-31-3533
with shut-off
Guide ring for shut-off BP/
8 11-31-3537
MP330
is not part of the feed pan cpl:
9 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
10 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 166 Spare parts

8.2.2 Big Pan 330 single components [control pans]

[11-31-3552] Control pan cpl BP330 incl sensor DOL 26

Pos. Code no. Description Graphics


1 11-31-3515 Tube adapter for BP/MP330
Cylinder inner white for BP/
2 83-11-2669 MP330 without shut-off for
sensor DOL 26
Cylinder outer for BP/MP/
3 11-31-3514
RPM330/MalePan
5 11-31-3512 Grille for feed pan BP330
5 11-31-3511 Dish BP330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.54 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 167

[11-31-3732] Control pan cpl BP330 plus including DOL 26

Pos. Code no. Description Graphics


1 11-31-3515 Tube adapter for BP/MP
Cylinder inner white for BP/
2 83-11-2669 MP330 without shut-off for
sensor DOL26
Cylinder outer for BP/MP/
3 11-31-3514
RPM330/MalePan
5 11-31-3512 Grille for feed pan BP330
5 11-31-3711 Dish RPM330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.54 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 168 Spare parts

[11-31-3553] Control pan cpl BigPan 330 including sensor DOL 44RG

Pos. Code no. Description Graphics


1 11-31-3515 Tube adapter for BP / MP330
2 Cylinder inner for control pan
Cylinder outer for BP / MP /
3 11-31-3514
RPM 330 / MalePan
4 Grille for control pan BP330
5 11-31-3511 Dish BP330
6 99-20-1026 Washer A 8.4 DIN 125 galv.
Hexagon head screw M 8 x 16
7 99-10-1046
galv. DIN 933 8.8
Pipe clamp 32-35 mm S M8
8 99-50-3036 galv. with sound absorbing
profile
9 60-40-0754 Sensor MS-45R 220V threaded
Strap 360 mm x 4.5 mm black
10 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2275 mm 4hole dia
11 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
12 11-31-3248 19.6 x 4.3 right AM/SA rng.mtr.
(=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 169

[11-31-3551] Control pan cpl BP330 excl sensor

Pos. Code no. Description Graphics


1 11-31-3515 Tube adapter for BP/MP330
2 Cylinder inner for control pan
Cylinder outer for BP/MP/
3 11-31-3514
RPM330/MalePan
4 Grille for control pan BP330
5 11-31-3511 Dish BP330
6 99-20-1026 Washer A 8.4 DIN 125 galv
Hexagon head screw M 8x 16
7 99-10-1046
DIN 933 8.8 galv
8 99-50-3036 Pipe clamp 32-35mm S M8 galv
is not part of the control pan cpl:
End tube 2775mm 4hole dia45
9 11-31-3529
BP330
Auger open core 35,4/45 right
10 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 170 Spare parts

8.2.3 FLUXX 330 single components [feed pans]

[11-31-4771] Feed pan complete FLUXX 330-14 without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-00-8716 Cylinder inner for FLUXX 330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
4 83-05-7350 Dish with latch for Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35.4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 171

[11-31-1521] Feed pan cpl FLUXX 330-14 with shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner with shut-off
2 83-06-7527
FLUXX330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
4 83-05-7350 Dish with latch for Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
Slide valve shut-off BP-2/
6 83-03-9615
FLUXX330
is not part of the feed pan complete:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 172 Spare parts

[11-31-4772] Feed pan cpl FLUXX 330-14 plus without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-00-8716 Cylinder inner for FLUXX 330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish with latch and pocket for
4 83-05-7349
Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
is not part of the feed pan complete:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 173

[11-31-1523] Feed pan cpl FLUXX 330-14 plus with shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner with shut-off
2 83-06-7527
FLUXX330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish with latch and pocket for
4 83-05-7349
Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
Slide valve shut-off BP-2/
6 83-03-9615
FLUXX330
is not part of the feed pan complete:
7 Tube 45x1,25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 174 Spare parts

[11-31-4747] Feed pan cpl FLUXX 330-14 w/AMX-dish wo/shut-off

Pos. Code no. Description Graphics


Grille 14-arm with latch for
1 83-05-8537
Fluxx330
Dish AMX with latch for
2 83-07-4711
Fluxx330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
4 83-00-8716 Cylinder inner for FLUXX 330
5 83-00-8718 Tube adapter for FLUXX 330
is not part of the feed pan complete:
6 Tube 45x1.25-3050 BP330
Auger open core 35.4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 175

[11-31-4745] Feed pan cpl FLUXX 330-14 w/AMX-dish w/shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner with shut-off
2 83-06-7527
FLUXX330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish AMX with latch for
4 83-07-4711
Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
Slide valve shut-off BP-2/
6 83-03-9615
FLUXX330
is not part of the feed pan complete:
7 Tube 45x1.25-3050 BP330
Auger open core 35.4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 176 Spare parts

[11-31-4773] Feed pan cpl FLUXX 330-5 without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-00-8716 Cylinder inner for FLUXX 330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
4 83-05-7350 Dish with latch for Fluxx330
Grille 5-arm with latch for
5 83-05-8480
Fluxx330
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35.4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 177

[11-31-1522] Feed pan cpl FLUXX 330-5 with shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner with shut-off
2 83-06-7527
FLUXX330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Grille 5-arm with latch for
4 83-05-8480
Fluxx330
5 83-05-7350 Dish with latch for Fluxx330
Slide valve shut-off BP-2/
6 83-03-9615
FLUXX330
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 178 Spare parts

[11-31-4774] Feed pan cpl FLUXX 330-5 plus without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-00-8716 Cylinder inner for FLUXX 330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish with latch and pocket for
4 83-05-7349
Fluxx330
Grille 5-arm with latch for
5 83-05-8480
Fluxx330
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 179

[11-31-1524] Feed pan cpl FLUXX 330-5 plus with shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner with shut-off
2 83-06-7527
FLUXX330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Grille 5-arm with latch for
4 83-05-8480
Fluxx330
Dish with latch and pocket for
5 83-05-7349
Fluxx330
Slide valve shut-off BP-2/
6 83-03-9615
FLUXX330
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 180 Spare parts

[11-31-4742] Feed pan cpl FLUXX 330-5 w/AMX-dish wo/shut-off

Pos. Code no. Description Graphics


Grille 5-arm with latch for
1 83-05-8480
Fluxx330
Dish AMX with latch for
2 83-07-4711
Fluxx330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
4 83-00-8716 Cylinder inner for FLUXX 330
5 83-00-8718 Tube adapter for FLUXX 330
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 181

[11-31-4740] Feed pan cpl FLUXX 330-5 with AMX-dish and shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner with shut-off
2 83-06-7527
FLUXX330
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish AMX with latch for
4 83-07-4711
Fluxx330
Grille 5-arm with latch for
5 83-05-8480
Fluxx330
Slide valve shut-off BP-2/
6 83-03-9615
FLUXX330
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 182 Spare parts

8.2.4 FLUXX 330 Single components [control pans]

[11-31-4776] Control pan FLUXX 330-14 including sensor DOL 26

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner for FLUXX330 for
2 83-11-2660
sensor DOL26
Cylinder outer with short fins
3 83-03-4691
FLUXX330
5 83-05-7350 Dish with latch for FLUXX330
Grille 14-arm with latch for
5 83-05-8537
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 183

[11-31-4829] Control pan FLUXX 330-14 including sensor DOL 44RG

Pos. Code no. Description Graphics


1 60-40-0754 Sensor MS45R 220V threaded
Cylinder outer white for
2 83-11-2662
FLUXX330 for sensor MS-45
Cylinder inner white for
3 83-11-2665
FLUXX330 for sensor MS-45
4 83-00-8718 Tube adapter for FLUXX330
Dish AMX with latch for
5 83-05-7350
FLUXX330
Grille 14-arm with latch for
6 83-05-8537
FLUXX330
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 184 Spare parts

[11-31-4777] Control pan FLUXX330-14 plus incl sensor DOL 26

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
Cylinder inner for FLUXX330 for
2 83-11-2660
sensor DOL 26
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish with latch and pocket for
4 83-05-7349
FLUXX330
Grille 14-arm with latch for
5 83-05-8537
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 185

[11-31-4839] Control pan FLUXX 330-14 plus including sensor DOL 44RG

Pos. Code no. Description Graphics


1 60-40-0754 Sensor MS45R 220V threaded
Cylinder outer white for FLUXX
2 83-11-2662
330 for sensor MS-45
Cylinder inner white for
3 83-11-2665
FLUXX330 for sensor MS-45
5 83-00-8718 Tube adapter for FLUXX330
Dish with latch and pocket for
5 83-05-7349
FLUXX330
Grille 14-arm with latch for
6 83-05-8537
FLUXX330
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 186 Spare parts

[11-31-4746] Control pan cpl FLUXX330-14 with AMX-dish

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX330
Cylinder inner for FLUXX330 for
2 83-11-2660
sensor DOL 26
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish AMX with latch for
5 83-07-4711
FLUXX330
Grille 14-arm with latch for
5 83-05-8537
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 187

[11-31-4778] Control pan FLUXX 330-5 including sensor DOL 26

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX330
Cylinder inner for FLUXX330 for
2 83-11-2660
sensor DOL 26
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish AMX with latch for
5 83-05-7350
FLUXX330
Grille 5-arm with latch for
5 83-05-8480
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 188 Spare parts

[11-31-4741] Control pan cpl FLUXX330-5 with AMX-dish

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX330
Cylinder inner white for
2 83-11-2660
FLUXX330 for sensor DOL 26
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish AMX with latch for
5 83-07-4711
FLUXX330
Grille 5-arm with latch for
5 83-05-8480
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 189

[11-31-4781] Control pan FLUXX330-5 plus incl sensor DOL 26

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX330
Cylinder inner for FLUXX330 for
2 83-11-2660
sensor DOL 26
Cylinder outer with short fins
3 83-03-4691
FLUXX330
Dish with latch and pocket for
5 83-05-7349
FLUXX330
Grille 5-arm with latch for
5 83-05-8480
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
9 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 190 Spare parts

8.2.5 FLUXX 360 Single components [feed pans]

[11-31-4670] Feed pan cpl FLUXX 360-16 wo/shut-off

Pos. Code no. Description Graphics


1 83-02-5351 Grille 16-arm for FXB/Fluxx360
Cylinder inner for tube dia 45
2 83-04-2526
Fluxx360 wo/shut-off
Tube adapter for tube dia 45mm
3 83-01-8947
FXB/Fluxx360
4 83-05-3327 Dish Fluxx360
Cylinder outer with short fins
5 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 191

[11-31-4675] Feed pan cpl FLUXX 360-16 w/shut-off

Pos. Code no. Description Graphics


1 83-02-5351 Grille 16-arm for FXB/Fluxx360
Cylinder inner for tube dia 45
2 83-01-8946
FXB/Fluxx360 with shut-off
3 83-02-5359 Slide shut-off FXB/Fluxx360
Tube adapter for tube dia 45mm
4 83-01-8947
FXB/Fluxx360
5 83-05-3327 Dish Fluxx360
Cylinder outer with short fins
6 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 192 Spare parts

[11-31-4770] Feed pan cpl FLUXX 360-16 plus without shut-off

Pos. Code no. Description Graphics


1 83-02-5351 Grille 16-arm for FXB/Fluxx360
Cylinder inner for tube dia 45
2 83-04-2526
Fluxx360 wo/shut-off
Tube adapter for tube dia 45mm
3 83-01-8947
FXB/Fluxx360
4 83-01-6343 Dish FXB 360
Cylinder outer with short fins
5 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 193

[11-31-4775] Feed pan cpl FLUXX 360-16 plus with shut-off

Pos. Code no. Description Graphics


1 83-02-5351 Grille 16-arm for FXB/Fluxx360
Cylinder inner for tube dia 45
2 83-01-8946
FXB/Fluxx360 with shut-off
3 83-02-5359 Slide shut-off FXB/Fluxx360
Tube adapter for tube dia 45mm
4 83-01-8947
FXB/Fluxx360
5 83-01-6343 Dish FXB360
Cylinder outer with short fins
6 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 194 Spare parts

[11-31-4680] Feed pan cpl FLUXX 360-8 without shut-off

Pos. Code no. Description Graphics


1 83-04-1097 Grille 8-arm for Fluxx360
Cylinder inner for tube dia 45
2 83-04-2526
Fluxx360 wo/shut-off
Tube adapter for tube dia 45mm
3 83-01-8947
FXB/Fluxx360
4 83-05-3327 Dish Fluxx360
Cylinder outer with short fins
5 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 195

[11-31-4685] Feed pan cpl FLUXX 360-8 with shut-off

Pos. Code no. Description Graphics


1 83-04-1097 Grille 8-arm for Fluxx360
Cylinder inner for tube dia 45
2 83-01-8946
FXB/Fluxx360 with shut-off
3 83-02-5359 Slide shut-off FXB/Fluxx360
Tube adapter for tube dia 45mm
4 83-01-8947
FXB/Fluxx360
5 83-05-3327 Dish Fluxx360
Cylinder outer with short fins
6 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
8 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
9 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 196 Spare parts

[11-31-4780] Feed pan cpl FLUXX 360-8 plus without shut-off

Pos. Code no. Description Graphics


1 83-04-1097 Grille 8-arm for Fluxx360
Cylinder inner for tube dia 45
2 83-04-2526
Fluxx360 wo/shut-off
Tube adapter for tube dia 45mm
3 83-01-8947
FXB/Fluxx360
4 83-01-6343 Dish FXB360
Cylinder outer with short fins
5 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 197

[11-31-4785] Feed pan cpl FLUXX 360-8 plus with shut-off

Pos. Code no. Description Graphics


1 83-04-1097 Grille 8-arm for Fluxx360
Cylinder inner for tube dia 45
2 83-01-8946
FXB/Fluxx360 with shut-off
3 83-02-5359 Slide shut-off FXB/Fluxx360
Tube adapter for tube dia 45mm
4 83-01-8947
FXB/Fluxx360
5 83-01-6343 Dish FXB360
Cylinder outer with short fins
6 83-06-9060
FXB/Fluxx360
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 198 Spare parts

8.2.6 FLUXX 360 Single components [control pans]

[11-31-4679] Control pan cpl. FLUXX360-16 without shut-off

Pos. Code no. Description Graphics


Grille 16-arm white for FXB /
1 83-02-5351
FLUXX 360
Cylinder inside white FLUXX360
2 83-11-2672
for sensor DOL 26
Tube adapter for tube dia 45
3 83-01-8947
FXB/FLUXX360
Sensor AFS-03 ST 90-250VAC
5 60-40-2919
sensitivity and adjustable delay
5 83-05-3327 Dish FLUXX360
Cylinder outer with short fins
6 83-06-9060
FXB/FLUXX360
not part of the control pan complete:
End tube 2775 mm 4 hole dia
7 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
8 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 199

[11-31-4779] Control pan cpl. FLUXX360-16 plus without shut-off

Pos. Code no. Description Graphics


Grille 16-arm white for FXB/
1 83-02-5351
FLUXX360
Cylinder inside white FLUXX360
2 83-11-2672
for sensor DOL 26
Tube adapter for tube dia 45
3 83-01-8947
FXB/FLUXX360
5 83-01-6343 Dish FXB360
Cylinder outer with short fins
5 83-06-9060
FXB/FLUXX360
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
not part of the control pan complete:
End tube 2775 mm 4 hole dia
7 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
8 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 200 Spare parts

[11-31-4689] Control pan cpl. FLUXX360-8 without shut-off

Pos. Code no. Description Graphics


Grille 8-arm white for
1 83-04-1097
FLUXX360
Cylinder inside white FLUXX360
2 83-11-2672
for sensor DOL 26
Tube adapter for tube dia 45
3 83-01-8947
FXB/FLUXX360
Sensor AFS-03 ST 90-250VAC
5 60-40-2919
sensitivity and adjustable delay
5 83-05-3327 Dish FLUXX360
Cylinder outer with short fins
6 83-06-9060
FXB/FLUXX360
not part of the control pan complete:
End tube 2775 mm 4 hole dia
7 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
8 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 201

[11-31-4789] Control pan cpl. FLUXX360-8 plus without shut-off

Pos. Code no. Description Graphics


Grille 8-arm white for
1 83-04-1097
FLUXX360
Cylinder inside white FLUXX360
2 83-11-2672
for sensor DOL 26
Tube adapter for tube dia 45
3 83-01-8947
FXB/FLUXX360
5 83-01-6343 Dish FXB360
Cylinder outer with short fins
5 83-06-9060
FXB/FLUXX360
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
not part of the control pan complete:
End tube 2775 mm 4 hole dia 45
7 11-31-3529
BP330
Auger open core 35.4 x 45 x
8 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 202 Spare parts

8.2.7 BigPan 2 Single components [feed pans]

[11-31-1531] Feed pan cpl BigPan 2 330-14 without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 wo/shut-
3 83-06-4537
off
4 83-05-7350 Dish with latch for Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 203

[11-31-4911] Feed pan cpl BigPan 2 330-14 w/shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 with
3 83-03-9613
shut-off
Slide valve shut-off BP-2/
4 83-03-9615
FLUXX330
5 83-05-7350 Dish with latch for Fluxx330
Grille 14-arm with latch for
6 83-05-8537
Fluxx330
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 204 Spare parts

[11-31-1533] Feed pan cpl BigPan 2 330-14 plus without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 wo/shut-
3 83-06-4537
off
Dish with latch and pocket for
4 83-05-7349
Fluxx330
Grille 14-arm with latch for
5 83-05-8537
Fluxx330
6 83-03-9795 Volume reducing shaft for BP-2
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 205

[11-31-4901] Feed pan cpl BigPan 2 330-14 plus w/shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 with
3 83-03-9613
shut-off
Slide valve shut-off BP-2/
4 83-03-9615
FLUXX330
5 83-03-9795 Volume reducing shaft for BP-2
Dish with latch and pocket for
6 83-05-7349
Fluxx330
Grille 14-arm with latch for
7 83-05-8537
Fluxx330
is not part of the feed pan cpl:
8 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
9 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 206 Spare parts

[11-31-1532] Feed pan cpl BigPan 2 330-5 without shut-off

Pos. Code no. Description Graphics


Feed pan cpl BigPan 2 330-5
1 83-00-8718
without shut-off
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 wo/shut-
3 83-06-4537
off
4 83-05-7350 Dish with latch for Fluxx330
Grille 5-arm with latch for
5 83-05-8480
Fluxx330
is not part of the feed pan cpl:
6 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
7 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 207

[11-31-4931] Feed pan cpl BigPan 2 330-5 w/shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 with
3 83-03-9613
shut-off
Slide valve shut-off BP-2/
4 83-03-9615
FLUXX330
5 83-05-7350 Dish with latch for Fluxx330
Grille 5-arm with latch for
6 83-05-8480
Fluxx330
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 208 Spare parts

[11-31-1534] Feed pan cpl BigPan 2 330-5 plus without shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 wo/shut-
3 83-06-4537
off
Dish with latch and pocket for
4 83-05-7349
Fluxx330
Grille 5-arm with latch for
5 83-05-8480
Fluxx330
6 83-03-9795 Volume reducing shaft for BP-2
is not part of the feed pan cpl:
7 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
8 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 209

[11-31-4921] Feed pan cpl BigPan 2 330-5 plus w/shut-off

Pos. Code no. Description Graphics


1 83-00-8718 Tube adapter for FLUXX 330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner for BP-2 with
3 83-03-9613
shut-off
Slide valve shut-off BP-2/
4 83-03-9615
FLUXX330
5 83-03-9795 Volume reducing shaft for BP-2
Dish with latch and pocket for
6 83-05-7349
Fluxx330
Grille 5-arm with latch for
7 83-05-8480
Fluxx330
is not part of the feed pan cpl:
8 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
9 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 210 Spare parts

8.2.8 BigPan 2 Single components [control pans]

[11-31-4919] Control pan cpl BigPan 2 330-14

Pos. Code no. Description Graphics


Grille 14-arm with latch for
1 83-05-8537
FLUXX330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner white for BP-2
3 83-11-2667 without shut-off for sensor DOL
26
5 83-00-8718 Tube adapter for FLUXX 330
5 83-05-7350 Dish with latch for FLUXX 330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
not part of the control pan complete:
End tube 2775 mm 4 hole dia
7 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
8 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 211

[11-31-4909] Control pan cpl BigPan 2 330-14 plus

Pos. Code no. Description Graphics


Grille 14-arm with latch for
1 83-05-8537
FLUXX330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner white for BP-2
3 83-11-2667 without shut-off for sensor DOL
26
5 83-03-9795 Volume reducing shaft for BP-2
5 83-00-8718 Tube adapter for FLUXX330
Dish with latch and pocket for
6 83-05-7349
FLUXX330
Sensor AFS-03 ST 90-250VAC
7 60-40-2919
sensitivity and adjustable delay
not part of the control pan complete:
End tube 2775 mm 4 hole dia
8 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
9 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 212 Spare parts

[11-31-4939] Control pan cpl BigPan 2 330-5

Pos. Code no. Description Graphics


Grille 5-arm with latch for
1 83-05-8480
FLUXX330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner white for BP-2
3 83-11-2667 without shut-off for sensor DOL
26
4 83-00-8718 Tube adapter for FLUXX330
Dish AMX with latch for
5 83-05-7350
FLUXX330
Sensor AFS-03 ST 90-250VAC
6 60-40-2919
sensitivity and adjustable delay
not part of the control pan complete:
End tube 2775 mm 4 hole dia
7 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
8 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 213

[11-31-4929] Control pan cpl BigPan 2 330-5 plus

Pos. Code no. Description Graphics


Grille 5-arm with latch for
1 83-05-8480
FLUXX330
2 83-03-9614 Cylinder outer for BP-2
Cylinder inner white for BP-2
3 83-11-2667 without shut-off for sensor DOL
26
5 83-03-9795 Volume reducing shaft for BP-2
5 83-00-8718 Tube adapter for FLUXX330
Dish with latch and pocket for
6 83-05-7349
FLUXX330
Sensor AFS-03 ST 90-250VAC
7 60-40-2919
sensitivity and adjustable delay
not part of the control pan complete:
End tube 2775 mm 4 hole dia 45
8 11-31-3529
BP330
Auger open core 35.4 x 45 x
9 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 214 Spare parts

8.2.9 MultiPan Single components [feed pans]

[11-31-3555] Feed pan cpl MP330 with shut-off and BP-dish

Pos. Code no. Description Graphics


1 11-31-3511 Dish BP330
2 11-31-3562 Grille MP330
Cylinder inner for MalePan with
3 83-00-0131
shut-off
Cylinder outer for BP/MP/
4 11-31-3514
RPM330/MalePan
5 11-31-3536 Slide shut-off BP/MP330
6 83-00-0130 Guide ring for shut-off MalePan
7 11-31-3515 Tube adapter for BP/MP330
is not part of the feed pan cpl:
8 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
9 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 215

[11-31-3565] Feed pan cpl MP330-plus with shut-off with RPM-dish

Pos. Code no. Description Graphics


1 11-31-3711 Dish RPM330
2 11-31-3562 Grille MP330
Cylinder inner for MalePan with
3 83-00-0131
shut-off
Cylinder outer for BP/MP/
4 11-31-3514
RPM330/MalePan
5 11-31-3536 Slide shut-off BP/MP330
6 83-00-0130 Guide ring for shut-off MalePan
Volume reducing insert white
7 11-31-3568
MP/RPM330
8 11-31-3515 Tube adapter for BP/MP330
is not part of the feed pan cpl:
9 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
10 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 216 Spare parts

8.2.10 MultiPan Single components [control pans]

[11-31-3557] Control pan cpl MP330 without BP-dish incl sensor DOL 26

Pos. Code no. Description Graphics


1 11-31-3511 Dish PP BP330
2 11-31-3562 Grille MP330
Cylinder inner white for
3 83-11-2679 "MalePan with shut-off" for
sensor DOL 26
Cylinder outer for BP/MP/
5 11-31-3514
RPM330/MalePan
5 11-31-3536 Slide shut-off BP/MP330
Guide ring for shut-off for sensor
6 83-00-9502
AFS
7 11-31-3515 Tube adapter for BP/MP330
Sensor AFS-03 ST 90-250VAC
8 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
9 11-31-4106
sensor AFS-03
Strap 100 mm x 2.5 mm black
10 99-50-3836
(UV-resistant)
Strap 360 mm x 4.5 mm black
11 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia
12 11-31-3529
45.0 BP330
Auger open core 35.4 x 45 x
13 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 217

[11-31-3567] Control pan cpl MP330-plus with RPM-dish incl sensor DOL 26

Pos. Code no. Description Graphics


1 11-31-3711 Dish RPM330
2 11-31-3562 Grille MP330
Cylinder inner white for
3 83-11-2679 "MalePan with shut-off" for
sensor DOL 26
Cylinder outer for BP/MP/
5 11-31-3514
RPM330/MalePan
5 11-31-3536 Slide shut-off BP/MP330
Guide ring for shut-off for sensor
6 83-00-9502
AFS
7 11-31-3515 Tube adapter for BP/MP330
Sensor AFS-03 ST 90-250VAC
8 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
9 11-31-4106
sensor AFS-03
Strap 100 mm x 2.5 mm black
10 99-50-3836
(UV-resistant)
Strap 360 mm x 4.5 mm black
11 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia 45
12 11-31-3529
BP330
Auger open core 35.4 x 45 x
13 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 218 Spare parts

8.2.11 FLUXX Breeder 360 Single components [feed pans]

[11-31-3815] Feed pan cpl FXB360 for tube dia 45 BB-rearing

Pos. Code no. Description Graphics


Feed pan cpl FXB360 for tube dia 45
1 83-01-8947
BB-rearing
2 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter rigidly
3 11-31-3597
mounted
Cylinder inner for tube dia 45 FXB/
4 83-01-8946 Fluxx360 with shut-off 45 PCS PER
CTN
5 83-01-6343 Dish FXB360
6 83-02-5359 Slide shut-off FXB/Fluxx360
7 83-02-5351 Grille 16-arm for FXB/Fluxx360
Cylinder outer with short fins FXB/
8 83-06-9060
Fluxx360
is not part of the feed pan cpl:
9 Tube 45x1.25-3050 Male-Pan
Auger open core 35,4/45 right AM/SA
10 11-31-3248
per running meter(=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 219

[11-31-3810] Feed pan cpl FXB360 for tube dia 45 BB-rearing & product.

Pos. Code no. Description Graphics


Feed pan cpl FXB360 for tube dia 45 BB-
1 83-01-8947
rearing & product.
2 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter rigidly
3 11-31-3597
mounted
Cylinder inner for tube dia 45 FXB/
4 83-01-8946
Fluxx360 with shut-off 45 PCS PER CTN
5 83-01-6339 Grille inner for FXB360
6 83-01-6345 Locking slide FXB360
7 83-01-6344 Levelling ring FO for FXB360
8 83-01-6340 Grille outer for FXB360
9 83-01-6343 Dish FXB360
10 83-02-5359 Slide shut-off FXB/Fluxx360
Cylinder outer with short fins FXB/
11 83-06-9060
Fluxx360
is not part of the feed pan cpl:
12 Tube 45x1.25-3050 Male-Pan
Auger open core 35,4/45 right AM/SA per
13 11-31-3248
running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 220 Spare parts

8.2.12 FLUXX Breeder 360 Single components [control pans]

[11-31-3819] Control pan cpl FXB360 d45 BB-rearing + sensor DOL 26

Pos. Code no. Description Graphics


Tube adapter for tube dia 45 FXB/
1 83-01-8947
FLUXX360
2 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter rigidly
3 11-31-3597
mounted
5 83-01-6343 Dish FXB360
5 83-02-5359 Slide shut-off FXB/FLUXX360
Grille 16-arm white for FXB/
6 83-02-5351
FLUXX360
Cylinder inner white for FXB360
7 83-11-2675
d45 for sensor DOL26
Cylinder outer with short fins FXB/
8 83-06-9060
FLUXX360
Sensor AFS-03 ST 90-250VAC
9 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
10 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black (UV-
11 99-50-3777
resistant)
not part of the control pan complete:
End tube 2775 mm 3 hole dia 45.0
12 11-03-3729
MalePan
Auger open core 35.4 x 45 x 19.6
13 11-31-3248 x 4.3 right / Augermatic / runn. m
(=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 221

[11-31-3809] Control pan cpl FXB360 d45 BB-rearing & production + sensor DOL
26

Pos. Code no. Description Graphics


1 83-01-8947 Tube adapter for tube dia 45 FXB/FLUXX360
2 11-31-3596 Compression spring D-207 J-01
3 11-31-3597 Holding pin for tube adapter rigidly mounted
4 83-01-6339 Grille inner for FXB360
5 83-01-6345 Locking slide FXB360
6 83-01-6344 Levelling ring FO for FXB360
7 83-01-6340 Grille outer orange for FXB360
8 83-01-6343 Dish FXB360
9 83-02-5359 Slide shut-off FXB/FLUXX360
Cylinder inner white for FXB360 d45 for
10 83-11-2675
sensor DOL 26
11 83-06-9060 Cylinder outer with short fins FXB/FLUXX360
Sensor AFS-03 ST 90-250VAC sensitivity and
12 60-40-2919
adjustable delay
13 11-31-4106 Protective hose 1500 mm for sensor AFS-03
14 99-50-3777 Strap 360 mm x 4.5 mm black (UV-resistant)
not part of the control pan complete:
15 11-03-3729 End tube 2775 mm 3 hole dia 45.0 MalePan
Auger open core 35.4 x 45 x 19.6 x 4.3 right /
16 11-31-3248
Augermatic / runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 222 Spare parts

8.2.13 MalePan Single components [feed pans]

[11-31-3585] Feed pan cpl MalePan with shut-off and BP-dish

Pos. Code no. Description Graphics


1 11-31-3511 Dish BP330
2 11-31-3562 Grille MP330
3 83-00-0131 Cylinder inner for MalePan with shut-off
Cylinder outer for BP/MP/RPM330/
4 11-31-3514
MalePan
5 11-31-3536 Slide shut-off BP/MP330
6 83-00-0130 Guide ring for shut-off MalePan
7 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter rigidly
8 11-31-3597
mounted
9 11-31-3587 Tube adapter PA for rigid Male Pan
is not part of the feed pan cpl:
10 Tube 45x1.25-3050 Male-Pan
Auger open core 35,4/45 right AM/SA
11 11-31-3248
per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 223

[11-31-3590] Feed pan cpl MalePan plus with shut-off and RPM-dish

Pos. Code no. Description Graphics


1 11-31-3562 Grille MP330
Cylinder outer for BP/MP/
2 11-31-3514
RPM330/MalePan
3 11-31-3536 Slide shut-off BP/MP330
Volume reducing insert white
4 11-31-3568
MP/RPM330
5 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter
6 11-31-3597
rigidly mounted
Cylinder inner for MalePan with
7 83-00-0131
shut-off
8 83-00-0130 Guide ring for shut-off MalePan
9 11-31-3711 Dish RPM330
Tube adapter PA for rigid Male
10 11-31-3587
Pan
is not part of the feed pan cpl:
11 Tube 45x1.25-3050 Male-Pan
Auger open core 35,4/45 right
12 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 224 Spare parts

8.2.14 MalePan Single components [control pans]

[11-31-3588] Control pan cpl MalePan w/BP-dish incl sensor DOL 26

Pos. Code no. Description Graphics


1 11-31-3511 Dish PP BP330
2 11-31-3562 Grille MP330
Cylinder inner white for "MalePan
3 83-11-2679
with shut-off" for sensor DOL 26
Cylinder outer for BP/MP/RPM330/
5 11-31-3514
MalePan
5 11-31-3536 Slide shut-off BP/MP330
Guide ring white for shut-off for
6 83-11-2686
sensor AFS
7 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter rigidly
8 11-31-3597
mounted
9 11-31-3587 Tube adapter PA for rigid MalePan
Sensor AFS-03 ST 90-250VAC
10 60-40-2919
sensitivity and adjustable delay
Protective hose 1500 mm for
11 11-31-4106
sensor AFS-03
Strap 100 mm x 2.5 mm black (UV-
12 99-50-3836
resistant)
Strap 360 mm x 4.5 mm black (UV-
13 99-50-3777
resistant)
not part of the control pan complete:
End tube 2775 mm 3 hole dia 45.0
14 11-03-3729
MalePan
Auger open core 35.4 x 45 x 19.6 x
15 11-31-3248 4.3 right / Augermatic / runn. m (=>
)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 225

[11-31-3595] Control pan cpl MalePan plus with RPM-dish incl sensor DOL 26

Pos. Code no. Description Graphics


1 11-31-3711 Dish RPM 330
2 11-31-3562 Grille MP330
Cylinder inner white for
3 83-11-2679 "MalePan with shut-off" for
sensor DOL 26
Cylinder outer for BP/MP/
5 11-31-3514
RPM330/MalePan
5 11-31-3536 Slide shut-off BP/MP330
Guide ring white for shut-off for
6 83-11-2686
sensor AFS
7 11-31-3596 Compression spring D-207 J-01
Holding pin for tube adapter
8 11-31-3597
rigidly mounted
Tube adapter PA for rigid
9 11-31-3587
MalePan
Sensor AFS-03 ST 90-250VAC
10 60-40-2919
sensitivity and adjustable delay
Strap 100 mm x 2.5 mm black
11 99-50-3836
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 3 hole dia
12 11-03-3729
45.0 MalePan
Auger open core 35.4 x 45 x
13 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 226 Spare parts

[11-31-3589] Control pan cpl MalePan-plus with RPM-dish including sensor DOL
44RG

Pos. Code no. Description Graphics


Cylinder inner for control pan MP330 + DOL
1 83-11-1239
44RG
2 83-00-0130 Guide ring for shut-off MalePan
3 11-31-3536 Slide shut-off BP/MP330
4 11-31-3515 Tube adapter for BP/MP330
5 11-31-3597 Holding pin for tube adapter rigidly mounted
6 11-31-3596 Compression spring D-207 J-01
7 11-31-3562 Grille for feed pan MP330
Cylinder outer for control pan MP330 + DOL
8
44RG
9 11-31-3711 Dish RPM330
10 11-31-3568 Volume reducing insert white MP/RPM330
11 60-40-0754 Sensor MS-45R 220V threaded
Strap 360 mm x 4.5 mm black (UV-
12 99-50-3777
resistant)
not part of the control pan complete:
13 11-03-3729 End tube 2775 mm 3 hole dia 45.0 MalePan
Auger open core 35.4 x 45 x 19.6 x 4.3 right
14 11-31-3248
AM/SA rng.mtr. (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 227

[11-31-3591] Control pan cpl MalePan-plus with RPM pan exclusive sensor

Pos. Code no. Description Graphics


Cylinder inner for control pan
1 83-11-1239
MP330 + DOL 44RG
2 83-00-0130 Guide ring for shut-off MalePan
3 11-31-3536 Slide shut-off BP/MP330
4 11-31-3515 Tube adapter for BP/MP330
Holding pin for tube adapter
5 11-31-3597
rigidly mounted
6 11-31-3596 Compression spring D-207 J-01
7 11-31-3562 Grille for feed pan MP330
Cylinder outer for control pan
8
MP330 + DOL 44RG
9 11-31-3711 Dish RPM330
Volume reducing insert white
10 11-31-3568
MP/RPM330
not part of the control pan complete:
End tube 2775 mm 3 hole dia
11 11-03-3729
45.0 MalePan
Auger open core 35.4 x 45 x
12 11-31-3248 19.6 x 4.3 right AM/SA rng.mtr.
(=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 228 Spare parts

8.2.15 Vista 360 Single components [feed pans]

[11-31-4860] Feed pan cpl Vista 360

Pos. Code no. Description Graphics


1 11-31-3515 Tube adapter for BP/MP330
2 83-09-1430 Dish for Vista 360
Rim with fins for dish for Vista
3 83-09-1429
360
4 83-09-1428 Cylinder outer for Vista 360
5 83-09-1427 Cylinder inner for Vista 360
is not part of the feed pan cpl:
8 Tube 45x1.25-3050 BP330
Auger open core 35,4/45 right
9 11-31-3248
AM/SA per running meter (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 229

8.2.16 Vista 360 Single components [control pans]

[11-31-4861] Control pan cpl. Vista 360

Pos. Code no. Description Graphics


1 11-31-3515 Tube adapter for BP/MP330
Cylinder outer control pan Vista
2 83-11-3062
with bracket for sensor DOL 26
Sensor AFS-03 ST 90-250VAC
3 60-40-2919
sensitivity and adjustable delay
5 83-09-1427 Cylinder inner for Vista 360
Rim with fins for dish for Vista
5 83-09-1429
360
6 83-09-1430 Dish for Vista 360
Protective hose 1500mm for
7 11-31-4106
sensor AFS-03
Strap 360 mm x 4.5 mm black
8 99-50-3777
(UV-resistant)
not part of the control pan complete:
End tube 2775 mm 4 hole dia 45
9 11-31-3529
BP330
Auger open core 35.4 x 45 x
10 11-31-3248 19.6 x 4.3 right / Augermatic /
runn. m (=> )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 230 Spare parts

8.3 Drive unit

! Important for ventilating the geared motor


The breather hole of the gear has to be opened before starting the drive
unit. This can be done by removing the sealing plug.

8.3.1 Drive unit AM6

(see also chapter )

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 231

Pos. Code no. Description


For drives: 11-31-5020; 11-03-3753:
1 11-31-5050 Motor 0.55kW 230/400V 50Hz 3Ph B5 cpl for drive AM6
For drive: 11-31-5021:
11-31-5046 Motor 0.55kW 220/380V 3Ph 60Hz cpl B5 f/drive AM6
For drives: 11-31-5022; 11-31-5023:
11-31-5047 Motor 0.55kW 200/346V 3Ph 50-60Hz cpl B5 f/drive AM6
For drive: 11-31-5024:
11-31-5048 Motor 0.55kW 230V 1Ph 50Hz cpl B5 f/drive AM6
For drive: 11-03-3705:
11-31-5049 Motor 0.75kW 230V 1Ph 50Hz S3 cpl B5 f/drive AM6
2 39-00-3279 Insulator EV/UV
3 83-08-6881 Suspension sheet for drive AM6
4 99-10-1292 Hexagon socket head cap screw M 8x20 DIN 912 galv
5 83-08-4122 Protection washer for output driveshaft 19,1x40x4 galv AM6
6 83-07-9239 Wire mesh guard for bracket of drive AM6
7 83-08-6654 Sleeve 50.8x2.9 - 50mm lg for tube dia 45mm / AM6
8 11-31-5043 Tube clip Norma dia 64 AM6
9 99-10-3947 Hooked bolt galv M 6x35 Augermatic
10 99-20-1043 Self-locking counter nut M 6 galv DIN985-6
11 83-07-9237 Front bracket drive AM6
For drives: 11-31-5020; 11-31-5022; 11-31-5024:
12 11-31-5042 Gearbox 4.31R for motor 50Hz B5 AM6
For drives: 11-31-5021; 11-31-5023:
11-31-5045 Gearbox 5.70R for motor 60Hz B5 AM6
For drive: 11-03-3753:
Drive 0.55kW 230/400V 50Hz AM6 Rapid-Rooster wo/sensor w/switch
11-31-5044 box
13 99-10-1058 Hexagon head screw M 8x 30 DIN 933 8.8 galv
14 99-10-1040 Hexagon nut M 8 galv DIN934-8
15 11-31-5041 Cover for switch box AM6
16 11-31-5036 Screw M 4x12 DIN 7500 galv switch-box AM6
17 11-31-5040 Ventilator cowl PP orange AM6
18 11-31-5038 Fan wheel for motor AM6
19 11-31-3744 Insulator conical (for corner RPM/Challenger)
20 99-10-4127 Hexagon socket head cap screw M 6x50 DIN 912-8.8 galv AM6
21 99-50-1147 Washer B 6.4 DIN 125 galv

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 232 Spare parts

8.3.2 Drive unit AM5

Figure 8-1: Drive unit AM5

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 233

Pos. Code no. Description


1 11-31-4502 Drive 0.37 kW 230V 1PH 50Hz AM5 without sensor with switch box
11-31-4512 Drive 0.37 kW 230/400V 60Hz AM5 without sensor with switch box
11-31-4552 Drive 0.37 kW 230/400V 50 Hz AM5 without sensor with switch box
11-31-4602 Drive 0.55 kW 230V 50 Hz AM5 without sensor with switch box
11-31-4612 Drive 0.55 kW 230/400V 60Hz AM5 without sensor with switch box
11-31-4613 Drive 0.55 kW 200V 3PH 60Hz AM5 without sensor with switch box
11-31-4652 Drive 0.55 kW 230/400V 50 Hz AM5 without sensor with switch box
11-31-4653 Drive 0.55 kW 200V 3PH 50 Hz AM5 without sensor with switch box
2 Anti-roost wire for drive AM5
3 Wire mesh guard for bracket of drive AM5
4 Bracket of drive AM5
5 Terminal box with integrated On- / Off switch
6 91-00-3905 Sensor AFS-01-60 seconds 90-250V
60-40-0654 Sensor MS-45R 220V without thread
7 99-50-0005 S-hook 2" no. 60 / 6x55
8 99-50-1077 Thimble 6 mm for cable 5 mm DIN 6899 NG 6 RW7 (=> 9 ”Glossary”)
9 99-50-0120 Safety cable clamp 5mm 3/16" DIN EN 13411-5 galv. NG5
10 99-50-3700 Wire rope 5 mm galv.
11 00-00-3006 Pulley 4 1/8" 105 mm with split strap
12 99-50-3003 U-bolt galvanized 8x25/W34/H50
13 11-31-3581 Bracket for cable winch 340 kg and hopper suspended AM/BP
14 99-20-1064 Self-locking counter nut M 8 DIN 985-6 galv.
15 99-50-0014 Cable clamp 3 mm 1/8" galv. DIN 741
16 99-50-1260 Wire rope 2 mm galv.
17 39-00-3096 Tension spring 2.0x14x134 C DIN 17223 galvanized
18 99-10-1152 Hexagon head screw M 5 x 50 galv. DIN 933 8.8
19 00-00-0032 Insulator porcelain anti-roost cable
20 99-10-1067 Hexagon head screw M 6 x 16 galv. DIN 933 8.8
21 11-31-1158 Bracket for insulator AM355
22 99-20-1033 Self-locking counter nut M 5 galv. DIN 985-6
23 11-31-1157 Clamp half for end anchor AM 355
24 99-10-1045 Hexagon nut M 6 galv. DIN 934
25 Tube AM / BP
26 End tube BP 330
27 11-31-3248 Auger open core 35.4 x 45 x 19.6 x 4.3 right AM/SA rng.mtr.
28 Shaft drive AM
29 99-10-3947 Hooked bolt M 6x35 Augermatic
30 99-20-1043 Self-locking counter nut M 6 DIN 985
31 83-00-4914 Sleeve 50x2.5-40 for tube dia 45/50.8
32 11-31-3211 Tube clip riveted complete
33 End anchor (Pos. 18 to 24)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 234 Spare parts

A= Plug for gear aeration is open

Motor with integrated thermostat relay:


The motor windings have thermostat relays for the overheating protection. These
relays protect the motor against too high temperatures and thus prevent a "jamming"
and "burning out" of the motor.

Warning:
This protective device does NOT replace the protective motor
switch.

Anti-perch fixture (2):


The AM drive 5 already comes with an anti-perch fixture, so that additional installation
works are not necessary.

Direct intervention well in the console:


The direct intervention well is dimensioned spaciously to allow for easy mounting of the
Augermatic spiral. It is closed with a plastic grid, which can easily be opened by
releasing the snap fasteners with a screw driver.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 235

Terminal box (5):


Integrated in the terminal box is a control relais and an On/Off switch for the drive.The
drive it protected by means of a flap against unintentional operation by the animals.
Also included in the terminal box are a micro-fuse for the sensor and an overheating
protection for the motor. This protective device does NOT replace the protective
motor switch, which has to be installed either externally on the gable wall or in a
central control box, as hitherto.

Tube adapter for 45 mm and 50,8 mm tubes


The AM drive 5 can be used with 50.8 mm or 45 mm tubes. When using a 45 mm tube,
a reducing bush (31) for the tube adaptor has to be installed at the drive.

Suspension eye:
By means of the suspension eye that is integrated in the motor housing the AM drive5
can easily be secured at the suspension cords of the feed circuit.

Gear aeration:
The vent of the gear - directly above the drive shaft - has to be opened before initiation
of the drive by pulling off the plug.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 236 Spare parts

8.3.3 AM4 drive unit

Pos. Code no. Description


11-31-3950 Drive 0.37 kW 230/400V 50Hz AM4 with sensor
11-31-3910 Drive 0.37 kW 230/400V 60 Hz AM4 with sensor
11-31-3900 Drive 0.37 kW 230V 1PH 50Hz AM4 with sensor
1 90-00-4055 Gear motor 0,37 kW 230/400V 50/60Hz 320r shaft 19 x 122 AM4
90-00-4065 Gear motor 0,37 kW 230V 50Hz 320r shaft 19 x 122 AM4
2 Bracket of drive AM4
3 Wire mesh guard
4 99-10-1241 Hexagon head screw M 5 x 12 galv. DIN 933 8.8
5 99-10-1088 Hexagon head screw M 6 x 20 galv. DIN 933 8.8
6 99-50-1147 Washer B 6.4 DIN 125
7 99-10-1045 Hexagon nut M 6 galv DIN 934

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 237

Pos. Code no. Description


8 99-10-3947 Hooked bolt M 6 x 35 Augermatic
9 99-20-1043 Self-locking counter nut M 6 DIN 985
10 Retaining bracket for tube clip AM4
11 99-10-1248 Hexagon head screw M 8 x 35 galv. DIN 933 8.8
12 99-20-1026 Washer A 8.4 DIN 125 galv.
13 99-10-1040 Hexagon nut M 8 galv DIN 934-8
14 Housing CI-K-1 95 TS complete
15 Performance protection 4 kW DOLOOM
16 Cable gland V-M20
17 Fuse holder
18 Fuse 5 x 20 G2A
19 60-40-0654 Sensor MS-45R 220V without thread
20 Suspension bracket AM4
21 39-00-3279 Insulator EV/UV
22 99-10-1152 Hexagon head screw M 5 x 50 galv. DIN 933 8.8
23 99-20-3706 Washer 5.3 x 25 x 1.25 galv.
24 99-10-1023 Hexagon nut M 5 galv DIN 934
25 11-31-3744 Insulator conical (for corner RPM/Challenger)
26 99-20-1003 Washer A 5.3 x 15 x 1.5 DIN 9021 stainless steel
27 99-20-1033 Self-locking counter nut M 5 galv. DIN 985-6
28 99-50-1260 Wire rope 2 mm galv.
29 99-50-0014 Cable clamp 3 mm 1/8" galv. DIN 741
30 99-50-0005 S-hook 2" no. 60 / 6x55
31 99-50-1077 Thimble 6 mm for cable 5 mm DIN 6899 NG 6 RW7 (=> 9 ”Glossary”)
32 39-00-3096 Tension spring 2.0 x 14 x 134 C DIN 17223 galv.
33 99-50-3700 Wire rope 5 mm
34 99-50-0120 Safety cable clamp 5 mm 3/16" DIN EN 13411-5 galv. NG5
35 00-00-3006 Pulley 4 1/8" 105 mm plastic
36 11-31-3581 Bracket for cable winch 340kg
37 99-50-3003 U-bolt galvanized 8x25/W34/H50
38 99-20-1064 Self-locking counter nut M 8 DIN 985-6 galv.
39 11-31-3547 Sleeve 48x1.5-40 for tube dia 45/47.6
40 End tube BP330
41 Tube AM/BP
42 11-31-1155 End anchor cpl anti-roost AM (Pos. 7, 27, 43-47)
43 99-10-1152 Hexagon head screw M 5 x 50 galv. DIN 933 8.8
44 00-00-0032 Insulator porcelain anti-roost cable
45 11-31-1158 Bracket for insulator AM355
46 11-31-1157 Clamp half for end anchor AM355
47 99-10-1067 Hexagon head screw M 6 x 16 galv. DIN 933 8.8
48 00-00-1186 Pictograph: Before maintenance work main switch "OFF"
49 00-00-1187 Pictograph: Protective devices

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 238 Spare parts

8.3.4 AM3 drive unit

Figure 8-2: drive unit AM3

Pos. Code no. Description


11-31-3650 Drive 0.55 kW 230/400V 50Hz AM3 with sensor
11-31-3660 Drive 0.55 KW 230/400V 60Hz AM3 with sensor
11-31-3600 Drive 0.55 kW 240V 1Ph 50Hz AM3 with sensor
1 90-00-3955 Gear motor 0.55 230/400 50Hz 326r shaft 19x122 AM3
90-00-3965 Gear motor 0.55 215/240 50 326r shaft 19x122 AM3
90-00-3975 Gear motor 0.55 230/400 50Hz AM3 257r shaft 19x122/F (=326r/
60Hz)
2 Suspension eye 2-hole for drive AM3
3 99-10-1023 Hexagon nut M5 galv DIN 934-8
4 99-10-3947 Hooked bolt galv. M 6x35 Augermatic
5 99-20-1043 Self-locking counter nut M 6 DIN 985
6 11-31-3601 Bracket cpl with fastening for switch-box AM3
7 99-10-1046 Hexagon head screw M 8 x 16 galv. DIN 933 8.8
8 99-50-1063 Spring washer A 8 DIN 127-A2E
9 11-31-3603 Mounting plate for switch box at bracket AM3

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 239

Pos. Code no. Description


10 99-10-3892 Tapping screw C 4.8 x 19 DIN 7981
11 11-31-1054 Switch box 230/400 50/60Hz for sensor
12 91-00-3312 Contactor LC1 DO910 P7 230V 50/60Hz
13 60-40-0654 Sensor MS-45R 220V without thread
14 11-31-3613 Protective covering of cables for drive 230/400V 3PH AM3 (Pos. 15-
17)
11-31-3614 Protective covering of cables for drive 240V 1PH AM3 (Pos. 15-17)
15 11-31-3615 Protective hose UW-PA6-10, 0.4m
16 99-30-1023 Screw union PG 16
17 11-31-3617 Cable Öflex 4 x 1.5, 0.4 m for 11-31-3613
11-31-3616 Cable Öflex 3 x 1.5, 0.4 m for 11-31-3614
18 11-31-3602 Fastening plate for wire mesh guard at bracket AM3
19 11-31-3604 Guard plate single for drive bracket AM5
20 99-10-1248 Hexagon head screw M 8 x 35 galv. DIN 933 8.8
21 99-10-1040 Hexagon nut M 8 galv DIN 934-8
22 99-20-1083 Serrated lock washer A 8.4 DIN 6798
23 11-31-3529 End tube 2775 mm 4 hole dia 45 BP330
24 11-31-3547 Sleeve 48x1,5-40 for tube dia 45/47,6
25 11-31-3581 Bracket for cable winch 340 kg and hopper suspended AM/BP
26 00-00-3006 Pulley 4 1/8" 105 mm plastic AMX150transit
27 99-50-3003 U-bolt galvanized 8x25/W34/H50
28 99-20-1064 Self-locking counter nut M 8 DIN 985-6 galv.
29 99-50-3700 Wire rope 5 mm
30 99-50-0120 Safety cable clamp 5mm 3/16" DIN EN 13411-5 galv. NG5
31 00-00-1186 Pictograph: Before maintenance work main switch "OFF"
32 00-00-1187 Pictograph: Protective devices

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 240 Spare parts

8.4 Anti-roost unit

8.4.1 Anti-roost wire for drive AM6

Pos. Code no. Description


1 Drive AM6
2 11-31-3744 Insulator conical (for corner RPM/Challenger)
3 39-00-3279 Insulator EV/UV
4 99-50-0014 Cable clamp 3mm 1/8" galv DIN 741
5 99-50-1260 Wire rope 2mm galv

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 241

8.4.2 Anti-roost device for AM5 drive

Figure 8-3: Anti-roost device for AM5 drive

Pos. Code no. Description


1 Tube AM
2 99-50-1260 Wire rope 2 mm galv.
3 99-50-0014 Cable clamp 3 mm 1/8" galv. DIN 741
4 39-00-3096 Tension spring 2.0x14x134 C DIN 17223 galvanized
5 11-31-1155 End anchor cpl anti-roost AM (Pos. 6-12)
6 99-20-1033 Self-locking counter nut M 5 galv. DIN 985-6
7 99-10-1152 Hexagon head screw M 5 x 50 galv. DIN 933 8.8
8 00-00-0032 Insulator porcelain anti-roost cable
9 11-31-1158 Bracket for insulator AM355
10 11-31-1157 Clamp half for end anchor AM355
11 99-10-1067 Hexagon head screw M 6 x 16 galv. DIN 933 8.8
12 99-10-1045 Hexagon nut M 6 galv DIN 934
13 Drive AM5
14 Anti-roost wire for drive AM5
15 Reducing bush (for tubes 50.8 mm to 45 mm)
16 11-31-3211 Tube clip riveted complete
17 91-00-3905 Sensor AFS-01-60 seconds 90-250 V
60-40-0654 Sensor MS-45R 220V without thread

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 242 Spare parts

8.4.3 Anti-roost device for AM4 drive

For mounting the anti-roost device for AM4 drive, see chapter 8.3.3 ”AM4 drive unit”.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 243

8.4.4 Anti-roost wire for drive AM3

The AM3 drive can be installed including an anti-roost device. The anti-
roost wire above the AM3 drive is connected to the wire above the
Augermatic tube and supplied with current if an electric fencer is used.
Replace the hexagon head screw M 5x50 of the end anchor cpl. anti-roost
AM and the insulator for anti-roost cable by a hexagon head screw m 5x35
and an insulator at the AM3 drive.The suspension eye 2-hole for AM3
drive has to be replaced by a suspension eye for AM3 drive.

Figure 8-4: Anti-roost device for AM3 drive

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 244 Spare parts

Figure 8-5: Explo Anti-roost device for AM3 drive

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 245

Anti-roost for AM3 drive

Pos. Qty. Code no. Description


1 Gear motor for Augermatic drive
2 11-31-3655 Anti roost for drive AM3 consisting of pos. 1-8
3 11-31-3606 Anti roost wire f/drive AM3
4 99-20-1033 Self locking counter nut M 5 galv. DIN 985
5 99-10-1097 Hexagon head screw M 5x16 galv. DIN 558
6 99-50-1146 Washer flat 5.3 DIN 433-ST
7 11-31-3608 Suspension eye for AM drive3
8 11-00-0307 Insulator at AM drive3
9 11-31-3611 Bracket for 2 insulators at AM drive
10 99-10-1420 Hexagon head screw M 5x35 galv. DIN 558
11 Suspension eye 2-hole for drive AM3
12 End tube BP330
13 11-31-1155 End anchor cpl. anti roost AM (pos. 12-18)
14 99-10-1152 Hexagon head screw M 5x50 galv. DIN 558
15 00-00-0032 Insulator porcelain anti-roost cable
16 11-31-1158 Bracket for insulator AM355
17 11-31-1157 Clamp half for end anchor AM 355
18 99-10-1067 Hexagon head screw M 6x16 galv. DIN 558
19 99-10-1045 Hexagon nut M 6 galv. DIN 934
20 99-50-1260 Wire rope 2mm galv.
21 99-50-0014 Cable clamp 3mm 1/8" galv. DIN 741
22 11-31-3581 Bracket for cable winch 340 kg and hopper suspended AM/
BP
23 00-00-3006 Pulley 4 1/8" 105mm plastic
24 99-50-3003 U-bolt galv. 8x25/W34/H48
25 99-20-1064 Self locking counter nut M 8 DIN 985-6 galv.
26 99-50-3700 Wire rope 5mm galv.
27 99-50-0120 Cable clamp 5mm 3/16" galv.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 246 Spare parts

8.5 Hopper

Feed hopper cpl 115l 1 line

Pos. Code no. Description


11-31-3540 Hopper 115l 1line cpl BP/AM 
for tube Ø 45 and 47.6
1 11-31-1316 Upper part for hopper 115l AM ZnAl
2 11-31-1304 Traverse f/suspension hopper AM+BP
3 11-31-3545 Lower part for hopper BP/AM for tube dia 45 and 50.8
4 99-10-1067 Hexagon head screw M 6x 16 DIN 933 8.8 galv
5 99-50-1147 Washer B 6.4 DIN 125 galv
6 99-20-1043 Self-locking counter nut M 6 galv DIN985-6

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 247

Pos. Code no. Description


7 99-50-1422 U-bolt hot-dip galv cpl 8x25/W52/H68.5 Pipe 2"
8 00-00-1188 Pictograph: Risk of injury / hopper
9 00-00-1173 Type plate: Big Dutchman 265mm x 80mm
10 11-31-1315 Wire mesh guard cpl for lower part of hopper BP/AM
consisting of:
11 11-31-1314 Wire mesh guard for lower part of hopper BP/AM
12 99-10-1602 Mushroom head square neck bolt M 6x 16 DIN 603 4.6 galv
13 99-10-3953 Washer 6.4x30x1.5 galv
14 99-20-1043 Self-locking counter nut M 6 galv DIN985-6

Feed hopper cpl 115l 2 lines

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 248 Spare parts

Pos. Code no. Description


11-03-3540 Hopper 115l 2lines centric BP/AM for tube Dia 45 and 47.6
1 11-31-1316 Upper part for hopper 115l AM ZnAl
2 11-31-1304 Traverse f/suspension hopper AM+BP
3 11-03-3541 Lower part for hopper 115L 2way central AM-Rapid-Rooster
4 99-10-1067 Hexagon head screw M 6x 16 DIN 933 8.8 galv
5 99-50-1147 Washer B 6.4 DIN 125 galv
6 99-20-1043 Self-locking counter nut M 6 galv DIN985-6
7 99-50-1422 U-bolt hot-dip galv cpl 8x25/W52/H68.5 Pipe 2"
8 00-00-1188 Pictograph: Risk of injury / hopper
9 00-00-1173 Type plate: Big Dutchman 265mm x 80mm
10 11-31-1315 Wire mesh guard cpl for lower part of hopper BP/AM
consisting of:
11 11-31-1314 Wire mesh guard for lower part of hopper BP/AM
12 99-10-1602 Mushroom head square neck bolt M 6x 16 DIN 603 4.6 galv
13 99-10-3953 Washer 6.4x30x1.5 galv
14 99-20-1043 Self-locking counter nut M 6 galv DIN985-6

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 249

Extension for feed hopper

Pos. Code no. Description


11-31-3521 Extension 48l for hopper 115l suspended AM Zn with screws
1 83-03-3277 Upper part for hopper 115 L AM ZnAl (zinc aluminium)
2 99-10-1100 Hexagon head screw M 6 x 12 galv. DIN 933 8.8
3 99-10-1045 Hexagon nut M 6 galv. DIN 934-8

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 250 Spare parts

8.5.1 Lower part for feed hopper

Lower part for feed hopper 1 line

Pos. Code no. Description


11-31-3545 Lower part for hopper BP/AM for tube dia 45 and 50.8
1 11-31-1104 Lower part for hopper AM (casing)
2 11-05-1082 Tension shaft cpl 19mm AM with Seeger ring+bearing housing
3 99-50-1422 U-bolt hot-dip galvanized cpl. 8x25/W52/H68.5 pipe 2"
4 35-00-1303 Lifting eye bolt M 5x 15
5 35-00-1023 Hexagon nut M 5 galv. DIN 934-8
6 99-20-1033 Self-locking counter nut M 5 galv. DIN 985-6

Lower part for feed hopper 2 lines

Pos. Code no. Description


1 11-31-1104 Boot f/hopper AM
2 11-05-1082 Tension shaft cpl 19mm AM w/Seeger ring+bearing hous.
3 99-50-1422 U-bolt hot-dip galv cpl 8x25/W52/H68.5 Pipe 2"
4 99-10-1303 Lifting eye bolt M 5x 15
5 99-10-1023 Hexagon nut M 5 galv DIN934-8
6 99-20-1033 Self-locking counter nut M 5 galv DIN985-6

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 251

8.5.2 Tension shaft complete

Pos. Code no. Description


1 Shaft 539mm for tension shaft with fastener round and guiding cone
2 Hex socket set screw M 5x8 DIN 913 hexagon socket / flat point
3 11-00-1052 Ball bearing S6203-RS
4 Bearing housing f/tension shaft cpl 19mm AM
5 99-50-1301 Retaining ring DIN472 40x1.75
6 99-50-1300 Retaining ring DIN471 17x1
7 99-50-1286 Spring type straight pin 5x30 DIN 1481
8 99-20-1081 Washer B 17 DIN 125 galv
9 83-09-2274 Cap rubber for Augermatic AM tension shaft

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 252 Spare parts

8.6 Cable winch 350 kg GS for wall mounting incl. hand crank
(99-50-3099)

If one cable is used:

Pos. Qty. Code no. Description


1 Retaining ring
2 Washer

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 253

Pos. Qty. Code no. Description


3 Bearing bush
4 Bracket
5 Retaining ring
6 Washer
7 Drive toothed wheel
8 Spacer
9 Brake disc
10 Ratchet wheel
11 Brake disc
12 Spacer
13 Shaft
14 Protective cover
15 Lock washer
16 Hex screw
17 Hex bolt
18 Washer
19 Plain bearing bush
20 Spring for locking pawl
21 Locking pawl
22 Retaining ring
23 Bearing bush
24 Washer
25 Retaining ring
26 Hand crank
27 Washer
28 Nut
29 Cable reel
30 Hex screw
31 Allen key screw
32 Nut
33 Cable clamp

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 254 Spare parts

If two cables are used:

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 255

Pos. Qty. Code no. Description


1 Retaining ring
2 Washer
3 Bearing bush
4 Bracket
5 Retaining ring
6 Washer
7 Drive toothed wheel
8 Spacer
9 Brake disc
10 Ratchet wheel
11 Brake disc
12 Spacer
13 Shaft
14 Protective cover
15 Lock washer
16 Hex screw
17 Hex bolt
18 Washer
19 Plain bearing bush
20 Spring for locking pawl
21 Locking pawl
22 Retaining ring
23 Bearing bush
24 Washer
25 Retaining ring
26 Hand crank
27 Washer
28 Nut
29 Cable reel
30 Hex screw
31 Cable screw
32 Thin nut

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 256 Spare parts

8.7 Feeders [single parts]

8.7.1 Feeder 30 ltr Empa 2 (20-00-3930)

1 20-00-3932 Upper part for Empa 2+3


2 20-00-3933 Shaft for Empa 2+3
3 20-00-3934 Bracket short for Empa 2+3
4 99-50-3808 Spring cotter 3mm
5 20-00-3935 Bracket long for Empa 2+3
Washer A 13.0x37x3.0 DIN
6 99-20-1150
9021 galv
Washer strengthened for Empa
7 20-00-3937
2
Hexagon nut M 12 galv DIN
8 99-20-1032
934-8
9 20-00-3936 Cover PVC for Empa 2
Dish Empa 2 dia 51cm/depth
10 20-00-3931
12cm
Figure 8-6: Feeder 30ltr Empa 2 (20-00-3930)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 257

8.7.2 Feeder 30ltr Empa 3 (20-00-3940)

1 20-00-3932 Upper part for Empa 2+3


2 20-00-3933 Shaft for Empa 2+3
3 20-00-3934 Bracket short for Empa 2+3
4 99-50-3808 Spring cotter 3mm
5 20-00-3935 Bracket long for Empa 2+3
Hexagon nut M 12 galv DIN
6 99-20-1032
934-8
7 20-00-3946 Cover galv for Empa 3
8 20-00-3947 Washer conic for Empa 3
Dish Empa 3 dia 37.5cm/depth
9 20-00-3941
7cm
Figure 8-7: Feeder 30ltr Empa 3 (20-00-3940)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 258 Spare parts

8.7.3 Feeder 30ltr Empa 4 (20-00-3950)

1 20-00-3932 Upper part for Empa 2+3


2 20-00-3933 Shaft for Empa 2+3
3 20-00-3934 Bracket short for Empa 2+3
4 99-50-3808 Spring cotter 3mm
5 20-00-3935 Bracket long for Empa 2+3
Self-locking counter nut M12
6 99-20-1082
galv DIN980-8
7 20-00-3936 Cover PVC for Empa 2
8 20-00-3957 Washer conic for Empa 4
Washer A 13.0x37x3.0 DIN
9 99-20-1150
9021 galv
Dish Empa 4 plastic dia 41cm/
10 20-00-3951
depth 8cm
Figure 8-8: Feeder 30 ltr Empa 4 (20-00-3950)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Spare parts Page 259

8.7.4 Feeder 12 ltr Picorett (11-31-3080)

1 Cover
2 Feed hopper
3 Adjusting spindle
4 Lower part of feeder
5 Plug
Assembly
1. Insert the square joining piece of the adjusting
spindle (3) into the lower part of the feeder
(Pos. 4) until it locks into place.
2. Screw the feeder hopper (Pos. 2) onto the
adjusting spindle (Pos. 3).
3. Fix the join of the cover (Pos.1) to the hinge of
the feed hopper (Pos. 2).
4. Insert the plug (Pos. 5) in the square joining
piece of the adjusting spindle (Pos. 3).

Figure 8-9: Feeder 12 ltr Picorett (11-31-3080)

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Page 260 Glossary

9 Glossary
Ad libitum feeding:
describes a feeding at which the birds can dispose freely of the respective feed portions
at any time, i.e. the feed is not portioned.

American Wire Gauge:


(abbreviation AWG) describes a coding for wire diameters and is mainly used in North
America. It characterizes electric lines from cords and solid wire and is particularly used
in the electrical engineering for the designation of the wire cross section.

Designated use:
is the correct use of product in accordance with its intended purpose.

Rated current:
designates the current of a protective switch specified by the manufacturer of an
electric device for a given operating condition.

Disinfection (hygiene):
is the targeted partial reduction of the germ number, especially on surfaces (decrease
in germ number).

Final growing period:


designates the last growing period during which the bird achieves the final (slaughter)
weight due to targeted feeding.

Incorrect use:
is improper use of a product, not in accordance with its intended purpose.

Rated quantity (for thimble DIN 6899):


(abbreviation NG) designates the largest possible rope diameter which may be used
for this thimble.

Running meter:
(abbreviation: r.m.) is a measuring unit which is used to measure goods which can be
purchased as merchandise, yard goods or roll goods and which dispose of an even
cross section, or length indications for invariant elements independent of their other
measures.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
Glossary Page 261

Live weight:
(abbreviation l.w.) designates the weight of a living, not fed or watered production
animal or animal for slaughter.

Restrictive feeding:
designates a feeding method with which only so much feed is given as can actually be
eaten by the animals.

Groove width (for thimble DIN 6899):


(abbreviation g.w.) designates the width of the groove in which the rope runs on the
thimble resp. in which it lies.

Protection class:
designates the suitability for different environmental conditions. The abbreviation IP is
for International Protection. The first code digit of the IP-code is for the protection
against foreign substances, the second digit stands for the protection against water.
The higher the number, the higher the existing protection.

State of the art:


represents the technical possibilities at a certain point in time, based on validated
scientific and technical knowledge.

Thermic:
(from Greek "thermos" = warm) designates figures, procedures, materials, processes,
theories, etc. which are connected with the noticeable exchange of heat or its effect
influence or which significantly influence temperature differences, isolation, hot gases
and the corresponding calculations or modelling.

Preparatory fattening:
designates a weight section during the phase feeding, from the time when the birds are
housed in until they have achieved a certain weight. During this time, the birds grow
quickly and do not become fat so soon since they get certain feed during this fattening
period.

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Edition: 01/2018 M 7218 GB
1 Checklist key points summary

Important! Please remember to cut this page and the following pages along the line from this manual and keep them save as blank
master copies!

Date Name

Check the following every day before the lights are switched on in your house:

Keypoints Result Note

functioning of the feed lines => exact monitoring of water and feed consumption can provide valuable information for bird
management

house climate=> ventilation, house temperature

physique and behaviour of the birds:=> select the birds and document the your daily selection and losses

bird distribution

birds' health

mortality

manure composition

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Page 1 / 6
Edition: 01/2018 M 7218 GB
The following should be controlled and documented daily during operation:

Keypoints Result Note

optimum height adjustment of the feed pans


=> rule-of-thumb: Height of the birds' backs = height of pan rim / Make sure that the cable winch is used correctly

proper and safe functioning of the cable winch

functioning of the conveying auger


=> e.g. noise development or warm places at the conveying tube

bird weight
=> achieve the desired bird weight for day seven by adjusting humidity and temperature, if necessary

birds' behaviour
=> in order to judge the climate conditions

air humidity during the first three days


=> try to maintain this at 60 - 70% and later at more than 50%

temperature, if this exceeds 70%


=> if necessary, reduce the temperature and monitor the birds' behaviour

temperature and minimum ventilation


=> to stimulate the birds' activity and appetite

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Page 2 / 6
Edition: 01/2018 M 7218 GB
The following should be controlled and documented daily during operation:

Keypoints Result Note

correct feed level adjustment of the feed pans

whether the protective grille is correctly fixed in the feed hopper

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Page 3 / 6
Edition: 01/2018 M 7218 GB
Control and document at each batch:

Keypoints Result Note

heat the house before moving the birds in until a temperature of 30°C is reached at the bird level
=> The correct moving-in temperature is the most important factor and significantly influences the fattening process!

make sure that the walls are sufficiently heated before bringing the litter in

are the conveying tubes aligned exactly horizontally

is the sensor correctly placed in the control pan and does it function properly?

are the feed pans tightly closed?

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Page 4 / 6
Edition: 01/2018 M 7218 GB
Control and document at each batch:

Keypoints Result Note

start the production computer 2 - 3 days before moving the birds in

fill feed line shortly before moving birds in


=> so that the birds can immediately start eating

the feed pans should be flooded for the first days to facilitate feed intake
(manual or automatic flooding device)

during the first hours and days after moving the birds in, make sure that all birds have found feed and water

on the first morning after moving the birds in, check if their crops are filled with feed and water
=> The crops of birds which have taken in feed and water are full, soft and rounded. If the crop is filled and hard, the bird
ate but did not drink. 95 to 100 % of crops should be filled 24 hours after moving-in.

the flooding mechanism shoud be turned off starting with the third day
=> to prevent feed wastage.

shorten the dark phases 3 days before the birds are moved out

shut off the feed supply 10 to 12 hours before the birds are moved out

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Page 5 / 6
Edition: 01/2018 M 7218 GB
Control and document at each batch:

Keypoints Result Note

clean the house and the equipment thoroughly after the moving-out procedure

in case of thermal disinfection, a temperature 60°C must not be exceeded

make sure that the system is refilled only one week after a wet cleaning
=> to prevent residual moisture in the conveying tubes

make sure that the cleaning water is drained off completely of the feed hopper

Augermatic (BP/Fluxx/BP2/MP/FXB/MalePan/Vista)
Page 6 / 6
Edition: 01/2018 M 7218 GB