Professional Documents
Culture Documents
Merlin Gerin EX10
Merlin Gerin EX10
CER
hot line
A team of specialists is on-hand to
answer your questions (1), making sure
information on the Internet you get the most out of your Pulsar
UPS.
If you need more information on our In addition, a special communications
UPSs or want to get in touch with your network group has access to all the
closest representative, visit our Web main platforms on the market to answer
site at: any questions you may have during
http://www.ups.merlin-gerin.com/ software installation.
(1) see the telephone number for your
country on the sticker supplied with
your Pulsar UPS.
MGE UPS SYSTEMS SA Austria: 0660 6215 Norway: 800 11 221 As standards, specifications and designs change from
7, chemin du Vieux Chêne Belgium: 0800 7 2189 United Kingdom: 0800 96 8558 time to time, please ask for confirmation of the
ZIRST 4202 China Hong-Kong: South east asia (Singapore): information given in this publication.
38942 Meylan Cedex (852) 2 811 2399 (65) 288 43 23
Denmark: 8001 0137 Spain: 900 99 3384
France
France: 0800 33 68 58 Sweden: 020 795 475
this document has been
Germany: 0130 81 9431 Switzerland: 155 1107
MGE UPS SYSTEMS S.A. printed on ecological paper
Italy: 1678 700 98 Other countries:
designs, manufactures and
Netherlands: 06022 3057 (33) (0) 4 76 33 91 36 Published by MGE UPS SYSTEMS - 10/96
markets Merlin Gerin brand
North america: 1 800 344 0570 Design by Studio Insign’ Seyssinet
UPSs.
Photos: Lucy in the Sky, Consumer
DAM31E0 Internet: www.ups.merlin-gerin.com Printed in France by Imprimerie des Deux Ponts
Pulsar EX
On-Line UPS
700 to 4000 VA
the ultimate power protection
for your workstations,
servers and communications
equipment
MERLIN GERIN
Pulsar EX for your peace of mind ...
modular, flexible, upgradable
reliability
you are, one thing is sure. Your rectifer
Contrary to a common belief, an charger inverter
electrical installation is exposed On-Line UPS does not continuously = output
input
to power problems. Blackouts, supply power drawn from the battery. =
The battery is used only as a backup
brownouts, sags, spikes, noise source. During normal operation, the
and surges, the list is long and input current is fully regenerated by
the causes many: continuous conversion from AC to DC, battery
then back to AC. This means you get
c weather conditions such as constant power quality no matter what
normal operation
operation on bypass (fault tolerance)
lightning and frost, happens on the mains. The On-Line operation on battery
technology implemented by Pulsar EX
c disturbances produced by guarantees the highest possible level Double-conversion On-Line UPS operating modes.
nearby equipment including of protection. The result is maximum
photocopiers, lifts and machine- availability for your workstations,
servers and network communications high-performance battery
tools, devices.
charger
c accidents such as people
The Pulsar EX battery charger uses
tripping on power cords or fault-tolerant system advanced technology to provide:
inadvertently pulling them out, or Pulsar EX UPSs are designed to keep c faster battery recharge,
your systems up and running, under all c longer battery life.
simply a circuit breaker doing its circumstances. In the event of an
job. overload or internal UPS fault, an And with its high-performance power
automatic bypass steps in and factor correction circuitry, Pulsar EX
transfers the load to the mains without also trims your electricity bill.
For your computer and any break in power. On Pulsar EX15 to
telecommunications systems, EX40 models, an additional manual
bypass (optional “hot-swap” module) extended backup time
the result can be fatal damage to lets you service the unit without for special needs
power supplies, hard disks and shutting down connected loads. For most situations, the standard
And Pulsar EX UPSs include a cold- Pulsar EX offers more than enough
electronic components. And start feature. This means they can be backup time. However, for special
even worse, lost data. started on battery power alone, ready needs, up to two EXB battery extension
to supply your loads even when mains modules can be added to boost your
power is unavailable. power reserve.
With Pulsar EX UPSs, you can With Pulsar EX, power availability is And because the extension modules
count on high-quality electrical always the top priority. are hot-swappable, your applications
power 24 hours a day, 365 days a stay up and running. A key advantage
in critical situations.
year. Even if mains power fails,
you keep on working as planned.
wide input-voltage window
for improved battery
What is more, an intelligent,
operation
microprocessor-based
Pulsar EX continuously optimises the
monitoring system detects any input-voltage range. As a result,
UPS operating problems and transfers to battery power are fewer
and shorter. The battery remains fully
indicates if service is required. charged, meaning better protection for
serious power mishaps and longer
With Pulsar EX, power problems battery life.
are a thing of the past.
TM
n-Pac
Solutio ed
includ
Pulsar EX7 / EX10 UPSs are really 340 VA Tower server + modular hub
discreet, yet always there when
280 VA 100-line PABX
you need them.
250 VA Office server / Unix workstation
to building-
…
…
…
…
…
!
– +
– +
%
management system
…
%
computer network
Simultaneous communication with two separate systems using the status-information board.
– +
– +
%
… – +
… %
… – +
SNMP board
… … – +
… !
… %
… – +
… – +
… % …
… – +
%
…
%
TM
n-Pac
Solutio ed
includ
Pulsar model EX15 to EX40 UPSs galvanic isolation for total fault tolerance and hot-swap
are a family of modular units peace of mind In the event of an overload or internal
designed to provide optimum Galvanic isolation enhances UPS fault, an optional automatic
connectivity. bypass steps in and transfers the load
protection and continuous power to the mains without any break in
Nothing to check, nothing to change in
to the key equipment in your the electrical installation. Trouble-free power. Added reliability to keep your
connection of as many loads as you equipment up and running.
business: servers, And to service without interrupting
like.
minicomputers, multi-user power, you simply insert a hot-swap
systems, telecommunications manual bypass module (option).
several hours of battery
devices, etc. backup time
They are a highly advanced, easy Add up to two EXB battery extension
to use and reliable means of modules to your Pulsar model EX15 to
EX40 UPSs for backup times of more
boosting your productivity. than one hour at full load and up to
Features include: four hours at half load.*
c continuous double-conversion The extra-long backup versions of
Pulsar EX30 and EX40 UPSs can
On-Line technology, with galvanic deliver power at full load for several
isolation, hours.
* depending on the version.
c wide input-voltage window
(84 to 276 V), Detachable manual
bypass module for
c automatic and/or detachable no-break service.
manual bypass (option),
battery backup time
c compact thanks to high- Power consumed
frequency technology, by protected loads
upright, ...
Customise the battery-test interval with EX-Driver. Pulsar EX, compact design, in a 19” bay ... flat.
– +
– +
%
UM-Agent Novell
functions that let you:
procedures, c connect the UPS to a server
+ UM-Client Novell
computer network Pulsar
c monitoring and controlling (UM-Agent), serial link
EX10
UPSs remotely. c remotely monitor and administer its
performance (UM-Console), Integration of all administration functions using
c automatically shut down one or more UM-Agent, UM-Client and UM-Console software
supplied on the Solution-PacTM CD-ROM.
This is why Solution-Pac™ servers in a multi-platform environment
(UM-Client),
includes all these functions on a c forward alerts to an SNMP
single CD-ROM, revolutionising supervision platform.
network-protection concepts.
for multi-platform
Designed for use in local or environments
Solution-Pac™ includes all the above
remote mode (SNMP), functions on a single CD-ROM for the
Solution-Pac™ covers all the most popular network environments
leading network environments. including NetWare, Windows NT,
Windows 95, SCO Unix, HP/UX,
IBM AIX, DEC Unix, SUN Solaris, UM-Console: powerful, user-friendly features.
And because these functions OS/2 LAN Server, etc.
In this way, you have immediate access
have become indispensable, to all the tools required to manage a Novell Windows NT
Solution-Pac™ comes with all Novell server locally for instance.
Pulsar EX UPSs, at no additional Subsequently, as your computer base
grows, you can manage it remotely,
cost. using SNMP protocol, while controlling …
…
…
…
…
!
Pulsar EX supervision
from an enterprise platform
using Management-Pac™
If your company implements network
management platforms such as HP
OpenView, IBM NetView 6000,
Sun Solstice or Novell ManageWise,
you can use the software on the
optional Management-Pac™
CD-ROM to monitor and administer the
Pulsar EX UPS from your supervisor.
Two UPSs and their peripherals (UM-Sensor and
UM-Switch) administered from an HP OpenView
workstation.
Pulsar EX
communications accessories
environment monitoring
with UM-Sensor
UM-Sensor is an optional module used
to monitor parameters such as the
temperature and relative humidity in a
computer or telecommunications room.
UM-Sensor can also manage up to
eight status signals, opening the way to
access control and other detection
applications (fire, water leaks, etc.).
All the above information may be
administered by an SNMP system and
forwarded to:
c a PC running the UM-Console
software included on the Solution-
Pac™ CD-ROM;
c a supervision platform running
software included on the Management-
Pac™ CD-ROM.
The UPS Manager 2 local adminis-
tration software for Unix / VMS / Open
VMS / OS2 can also be linked to UM-
Sensor. Action files may be invoked in
UM-Switch module. conjunction with alarms, for example to
automatically shutdown the system
UM-Switch for expanded UM-Switch is fully compatible with the following reception of an alarm or send
PowerShare™ features MGE UPS Systems software offering: a message via a modem to your pager.
c UPS Manager
The optional UM-Switch module lets c Solution-Pac™,
you implement Powershare™ features c Management-Pac™.
from your PC, using EX-Driver
software, or from a network
administration station, using
Solution-Pac™ or Management-Pac™
software.
The UM-Switch outlets can be remote-
controlled to:
c reset a remote device, for example a
switch in a rack, UM-Sensor module
c assign a battery run time to each
outlet to increase the backup time
available for the most critical loads. The
result is several hours of uninterrupted
service for priority loads such as
servers or internetworking devices,
c sequence the powering of connected
equipment to ensure startup in the
desired order, avoiding simultaneous Schedule the startup and shutdown times of
UM-Switch outlets using UM-Console.
starts and the associated overloads;
c monitor the supply of power to each
protected load.
remote indications
with Monitor-Ligth™
If you need a remote display* of the
current UPS operating mode (load on
battery, load on automatic bypass, etc.)
and alarm messages (low-battery
shutdown warnings, mains outage,
operation on bypass, etc.), the Monitor-
Light™ mini-terminal is the right
solution.
* up to 100 meters.
Monitor-LigthTM.
Pulsar EX7 / EX10
delivery pack contents
operation on AC input
c two CEE cords to connect your … %
… – +
operation on battery
computer hardware, … Rear view of Pulsar EX7 / EX10
load powered
c a warranty card. %
ware to Pulsar
c Monitor-Light™ mini-terminal,
Ue/In
EX7/EX10
AC input socket (supplied)
c FT filtered outlet block (4 additional
outlets).
– +
battery fault
c one DB9 communications cable, …
operation on manual bypass
c one user manual in six languages, %
…-
operation on battery
c a warranty card.
The connection kit is specific to each load level measurement
test
version:
%
on/off “U-Talk”
c “plug-in” version: communications port
four outlets* and an AC input socket; “status information”
SNMP
c “fault-tolerant” version: communications communications port
four outlets*, an AC input socket and an port
automatic bypass, automatic
bypass
c “hot-swap” version:
four outlets*, an AC input socket, input Pulsar EXB
Front view battery connector
and output terminal blocks, an circuit breaker
of Pulsar EX15 to EX40
automatic bypass and a detachable
manual bypass, CEE
c “install” version: power cord
(supplied)
input and output terminal blocks,
an AC input socket, automatic bypass,
detachable manual bypass.
* USE, DIN, BS
Rear view
options of Pulsar EX15 to EX40
c EXB15 / 20, EXB30, EXB 40 battery
extension modules,
c Management-Pac™ CD-ROM,
c internal SNMP board, detachable
c isolation transformer, manual bypass
with terminal
c automatic bypass module, blocks
c detachable manual bypass module, 4 outlets detachable
c 19” rack-mount kit, manual bypass with
c UM-Switch module, 4 outlets and terminal blocks
c UM-Sensor module,
c Monitor-Light™ mini-terminal,
c FT filtered outlet block (4 additional
outlets).
Pulsar EX
main characteristics