Professional Documents
Culture Documents
Mechanical Accessories Forpressure Measuring Devices
Mechanical Accessories Forpressure Measuring Devices
Special Documentation
Mechanical accessories for
pressure measuring devices
Pressure measurement
Your benefits
• A single supplier for the transmitter and accessories ensures that everything is
delivered in one shipment and no parts are missing
• The transmitter and accessories match
• One central point of contact
Mechanical accessories for pressure measuring devices
Table of contents
2 Endress+Hauser
Mechanical accessories for pressure measuring devices
32 (1.26)
10150 700
NPT ½"
NPT ½"
NPT ¼"
8700 600
B
156 (6.14)
7250 500
C
5800 400
4350 300
A
2900 200
1450 100
97 (3.82)
D
0 0 [°C]
0 100 200 300 400
[°F]
0 212 392 572 752
A0028016
Housing 1.4404
Locknut 1.4401
1) Product Configurator DA63M order code for "Version", option "TB2"; Product Configurator Cerabar order
code for "Accessories enclosed" option "P2" or "Accessories mounted" option "N2"
2) Pay attention to the pressure and temperature limits of the measuring device!
Endress+Hauser 3
Mechanical accessories for pressure measuring devices
10150 700
32 (1.26)
FNPT ½"
FNPT ½"
8700 600
NPT ¼"
B 7250 500
156 (6.14)
C 5800 400
4350 300
A 2900 200
1450 100
114 (4.49) D
0 0 [°C]
0 100 200 300 400
[°F]
0 212 392 572 752
A0028012
1) Product Configurator DA63M order code for "Version", option "TB2"; Product Configurator Cerabar order
code for "Accessories enclosed" option "P2" or "Accessories mounted" option "N2"
2) Product Configurator DA63M order code for "Version", option "TB3"; Product Configurator Cerabar order
code for "Accessories enclosed" option "P8" or "Accessories mounted" option "N8"
3) Pay attention to the pressure and temperature limits of the measuring device!
4 Endress+Hauser
Mechanical accessories for pressure measuring devices
32 (1.26)
7250 500
NPT ¼"
G ½"
G ½"
5800 400
148 (5.83)
B
4350 300
C 2900 200
1450 100
A D
0 0 [°C]
0 100 200 300 400
117 (4.61) [°F]
0 212 392 572 752
A0028017
1) Product Configurator DA63M order code for "Version", option "TB2"; Product Configurator Deltabar order
code for "Accessories enclosed" option "P2" or "Accessories mounted" option "N2"
2) Product Configurator DA63M order code for "Version", option "TB3"; Product Configurator Deltabar order
code for "Accessories enclosed" option "P8" or "Accessories mounted" option "N8"
3) Pay attention to the pressure and temperature limits of the measuring device!
Endress+Hauser 5
Mechanical accessories for pressure measuring devices
5800 400
4350 300
2900 200
~105 (4.13)
1450 100
C D [°C]
0 0
0 100 200 300 400
[°F]
0 212 392 572 752
54 (2.13)
72 (2.83)
108 (4.25) B
147 (5.79)
3
1 2
)
(0.49
)
.95)
(1.63
A
.95)
(0.55
0.1)
.5)
ø12.5
25 (0
4
25 (0
41.3
38 (1
ø14
2 .5 (
5
.76)
31)
70 (2
8 (0.
M10
50 (1
22 (0 .97)
.87)
41 (1
.61)
A0027677
A Process side
B Transmitter side
C PTFE packing
D Pure graphite packing
1, 2 The transmitter can be disconnected from the impulse lines with valves 1 and 2.
3 Valve 3 is used for zero point compensation between the impulse lines.
4 Cutting ring
5 Weld connection
6 Endress+Hauser
Mechanical accessories for pressure measuring devices
Description
Valve stem Cold-rolled surface, with back seat and non-rotating needle tip
Input Bite ring fitting for tube ⌀12 mm (0.47 in), series S, G 3/8
Welding nipples for tube ⌀ 14 x 2.5 mm
Housing temperature –10 to +300 °C (+14 to +572 °F) –40 to +300 °C (–40 to +572 °F)
application limits
Fixing screws Carbon steel ASTM A449, Type 1 1.4301 ASTM A193 B8 CI.2
Seal • PTFE: –10 to +80 °C (+14 to +176 °F) (in accordance with EN61518)
• FKM Viton: –15 to +120 °C (+5 to +248 °F)
• Graphite: –40 to +120 °C (–40 to +248 °F) (in accordance with EN61518)
Endress+Hauser 7
Mechanical accessories for pressure measuring devices
5800 400
4350 300
2900 200
1450 100
M10 C D E
0 0 [°C]
30 (1.18) 0 100 200 300 450 550
54 (2.13) [°F]
0 212 392 572 842 1022
101 (3.98)
B
NPT ½"
ø106 (4.17)
3
1 2
31.2 (1.23)
A0027747
A Process side
B Transmitter side
C PTFE packing
D Pure graphite packing 1.0460
E Pure graphite packing 1.4404
1, 2 The transmitter can be disconnected from the impulse lines with valves 1 and 2.
3 Valve 3 is used for zero point compensation between the impulse lines.
4 Distance between impulse line inputs.
8 Endress+Hauser
Mechanical accessories for pressure measuring devices
Valve stem Cold-rolled surface, with back seat and non-rotating needle tip
Housing temperature –10 to +450 °C (+14 to +842 °F) –40 to +550 °C (–40 to +1 022 °F)
application limits
Fixing screws Carbon steel ASTM A449, Type 1 1.4301 ASTM A193 B8 CI.2
Seal • PTFE: –10 to +80 °C (+14 to +176 °F) (in accordance with EN61518)
• FKM Viton: –15 to +120 °C (+5 to +248 °F)
• Graphite: –40 to +120 °C (–40 to +248 °F) (in accordance with EN61518)
Endress+Hauser 9
Mechanical accessories for pressure measuring devices
psi bar
7250 500
5800 400
4350 300
NPT ¼"
B
NPT ½"
115 (4.53)
C C
4 3 5
6 1 2
A
31.2 (1.23)
A0027748
A Process side
B Transmitter side
C Venting
D PTFE packing
E Pure graphite packing 1.0460
F Pure graphite packing 1.4404
1, 2 The transmitter can be disconnected from the impulse lines with valves 1 and 2.
3 Valve 3 is used for zero point compensation between the impulse lines.
4, 5 The impulse lines can be vented or blown clear with valves 4 and 5.
6 Vent connection NPT ½", female
7 Distance between impulse line inputs.
10 Endress+Hauser
Mechanical accessories for pressure measuring devices
Description
Valve stem Cold-rolled surface, with back seat and non-rotating needle tip
Housing temperature –10 to +550 °C (+14 to +1 022 °F) –40 to +550 °C (–40 to +1 022 °F)
application limits
Fixing screws Carbon steel ASTM A449, Type 1 1.4301 ASTM A193 B8 CI.2
Seal • PTFE: –10 to +80 °C (+14 to +176 °F) (in accordance with EN61518)
• FKM Viton: –15 to +120 °C (+5 to +248 °F)
• Graphite: –40 to +120 °C (–40 to +248 °F) (in accordance with EN61518)
Endress+Hauser 11
Mechanical accessories for pressure measuring devices
psi bar
7
5800 400
4350 300
51 (2.01)
2900 200
1450 100
D E [°C]
54 (2.13) 0 0
0 100 200 300 400
72 (2.83) [°F]
108 (4.25) 8 0 212 392 572 752
175 (6.89)
252 (9.92) B
3
)
)
1 2
(0.49
(1.63
C C
4 A 5
)
5
.95)
(0.55
41.3
.98)
ø12.
0.1)
25 (0
25 (0
31)
6
.5)
ø14
.97)
2 .5 (
7
8 (0.
38 (1
50 (1
M10 50 (1
.97)
22 (0
.87)
4 1 (1
.61)
A0027749
A Process side
B Transmitter side
C Blow clear
D PTFE packing
E Pure graphite packing
1, 2 The transmitter can be disconnected from the impulse lines with valves 1 and 2.
3 Valve 3 is used for zero point compensation between the impulse lines.
4, 5 The impulse lines can be vented or blown clear with valves 4 and 5.
6 Bite ring fitting
7 Weld connection
8 Distance between impulse line inputs.
12 Endress+Hauser
Mechanical accessories for pressure measuring devices
Description
Valve stem Cold-rolled surface, with back seat and non-rotating needle tip
Inlet/blow clear Bite ring fitting for tube ⌀12 mm (0.47 in), series S, G 3/8
Welding nipples for tube ⌀ 14 x 2.5 mm
Housing temperature –10 to +300 °C (+14 to +572 °F) –40 to +300 °C (–40 to +572 °F)
application limits
Fixing screws Carbon steel ASTM A449, Type 1 1.4301 ASTM A193 B8 CI.2
Seal • PTFE: –10 to +80 °C (+14 to +176 °F) (in accordance with EN61518)
• FKM Viton: –15 to +120 °C (+5 to +248 °F)
• Graphite: –40 to +120 °C (–40 to +248 °F) (in accordance with EN61518)
Endress+Hauser 13
Mechanical accessories for pressure measuring devices
12.5 (0.49)
7
psi bar
41.3 (1.63)
5800 400
21.5 (0.85)
43 (1.69)
142 (5.59)
4350 300
2900 200
1450 100
D E
0 0 [°C]
8 (0.31)
B
22 (0.87)
30 (1.18)
41 (1.61)
3
L
1 2
C C
4 A 5
11 (0.43)
50 (1.97)
170 (6.69)
230 (9.06)
A0027750
A Process side
B Transmitter side
C Purge valve
D PTFE packing
E Pure graphite packing
1, 2 The transmitter can be disconnected from the impulse lines with valves 1 and 2.
3 Valve 3 is used for zero point compensation between the impulse lines.
4, 5 The impulse lines can be vented or blown clear with valves 4 and 5.
6 Distance between impulse line inputs.
14 Endress+Hauser
Mechanical accessories for pressure measuring devices
Description
Valve stem Cold-rolled surface, with back seat and non-rotating needle tip
Outlet, purge valve Bite ring fitting for tube 14 mm (0.55 in), series S
Housing temperature –10 to +200 °C –10 to +550 °C –40 to +200 °C –40 to +550 °C
application limits (+14 to +392 °F) (+14 to +1 022 °F) (–40 to +392 °F) (–40 to +1 022 °F)
Fixing screws Carbon steel ASTM A449, Type 1 1.4301 ASTM A193 B8 CI.2
Seal • PTFE: –10 to +80 °C (+14 to +176 °F) (in accordance with EN61518)
• FKM Viton: –15 to +120 °C (+5 to +248 °F)
• Graphite: –40 to +120 °C (–40 to +248 °F) (in accordance with EN61518)
Endress+Hauser 15
Mechanical accessories for pressure measuring devices
27 100 (3.94) 27
125 (4.92)
50 (1.97)
27
50 (1.97)
27
20 (0.79)
G ½"
M20 x 1.5
79 (3.11)
G ½"
C D
NPT ½"-14
27
105 (4.13)
125 (4.92)
50 (1.97)
50 (1.97)
27
27
NPT ½"-14
14 (0.55)
20 (0.79)
Ø14
79 (3.11)
psi bar
5800 400
4350 300
2900 200
1450 100
0 0 [°C]
0 100 200 300 400
[°F]
0 212 392 572 752
A0027942
16 Endress+Hauser
Mechanical accessories for pressure measuring devices
Design
1)
B Ermeto 12S G ½" female, adjusting nut 1 B 2)
1) 2)
C Weld connection G ½" female, adjusting nut 1 C
1)
D MNPT ½" FNPT ½", internal 1 D 2)
Technical data
1) Product Configurator, order code for "Valve body; seal", option "1"
2) Cerabar M: Product Configurator, order code for "Accessories enclosed", option "P2"
3) Product Configurator, order code for "Valve body; seal", option "2"
4) Pay attention to the pressure and temperature limits of the measuring device!
Endress+Hauser 17
Mechanical accessories for pressure measuring devices
27
100 (3.94)
106 (4.17)
54 (2.13)
27 27
27
20 (0.79)
13 (0.51)
G ½" NPT ½"-14
27 27
125 (4.92)
125 (4.92)
54 (2.13)
54 (2.13)
27 27
20 (0.79)
Ø14
psi bar ø12 (0.47)
5800 400
4350 300
2900 200
1450 100
0 0 [°C]
0 100 200 300 400
[°F]
0 212 392 572 752
A0027943
18 Endress+Hauser
Mechanical accessories for pressure measuring devices
Design
Technical data
1) Product Configurator, order code for "Valve body; seal", option "1"
2) Cerabar M: Product Configurator, order code for "Accessories enclosed", option "P2"
3) Product Configurator, order code for "Valve body; seal", option "2"
4) Pay attention to the pressure and temperature limits of the measuring device!
Endress+Hauser 19
Mechanical accessories for pressure measuring devices
Version
PZAV-##A#
Shut-off valve order code PZAV-##D# PZAV-##B# -
PZAV-##C#
DA63M-TB#BFG DA63M-A#####
DA63M-B#####
DA63M-TB#BGG DA63M-C#####
Manifold order code DA63M-TB2BHH
DA63M-D#####
DA63M-K#####
DA63M-L#####
Deltabar S PMD75
- - All NPT1/4-18 IEC61518 process connections
Deltabar M PMD55
Cerabar S PMP71
RA, RB, RC, RD, RE, RF GA, GB - -
Cerabar S PMC71
Cerabar M PMP51
RKJ, RKC, RLJ, RLC, RJF GCJ, GCC, GCF - -
Cerabar M PMC51
Cerabar PMP11/21
VWJ, VXJ WBJ - -
Cerabar PMC11/21
Deltabar FMD71
RKJ, RKC, RLJ, RLC, RJF GCJ, GCC, GCF - -
Deltabar FMD72
20 Endress+Hauser
Mechanical accessories for pressure measuring devices
41.3 (1.63)
A0027940
Use The oval flange adapter is used to connect the impulse lines to the oval flange process connection of
the differential pressure transmitter (IEC 61518).
Seal 4) 5) • PTFE: –10 to +80 °C (+14 to +176 °F) (in • PTFE: –10 to +80 °C (+14 to +176 °F) (in
accordance with EN61518) accordance with EN61518)
• FKM Viton • FKM Viton
Endress+Hauser 21
Mechanical accessories for pressure measuring devices
Installation and The shutoff valves must be closed on completion of the installation. As part of routine
commissioning commissioning, the shutoff valves must first be opened carefully and the integrity of the entire
system checked to ensure it is leak-tight.
4350 300
81 (3.19)
ø12 (0.47)
2900 200
M20x1.5
1450 100
B C
0 0 [°C]
0 100 200 300 400
[°F]
64 (2.52) 0 212 392 572 752
A0027977
Technical data
22 Endress+Hauser
Mechanical accessories for pressure measuring devices
95 (3.74)
95 (3.74)
ø12 (0.47)
M20x1.5
NPT ½"
G ½"
13.6 (0.54) 22 (0.87)
90 (3.54) 90 (3.54)
psi bar
ø80 (3.15)
C 5800 400
4350 300
21.3 (0.84)
95 (3.74)
12.2 (0.48)
2900 200
ø12 (0.47)
1450 100
M20x1.5
D E
0 0 [°C]
0 100 200 300 400
[°F]
0 212 392 572 752
90 (3.54)
A0027970
Endress+Hauser 23
Mechanical accessories for pressure measuring devices
Technical data
1) 2)
"C22.8" version "316Ti" version
24 Endress+Hauser
Mechanical accessories for pressure measuring devices
ø120 (4.72)
psi bar
7250 500
5800 400
140 (5.51)
14.9 (0.59)
4350 300
9 (0.35)
14 (0.55)
2900 200
A
1450 100
B
0 0 [°C]
0 100 200 300 400 500
5 (0.2) 5 (0.2) [°F]
0 212 392 572 842 1022
65 (2.56)
130 (5.12)
A0028332
A Weld connection, inlet 21.3 mm (0.84 in) or 17.2 mm (0.68 in); weld connection, outlet 14 mm (0.55 in)
B Pure graphite packing
Technical data
"16Mo3" version 1)
Housing 1.5415
Bonnet 1.7709
Endress+Hauser 25
Mechanical accessories for pressure measuring devices
psi bar
4350 300
2900 200
1450 100
0 0 [°C]
0 100 200 300 400
[°F]
0 212 392 572 752
A0028335
Use
Siphons according to DIN 16282 are used to cool the medium. Suitable for liquids, gases and vapors.
Function
The pressure transmitter is separated from the process by the O-shaped pipe (vertical installation) or
the U-shaped pipe (horizontal installation). In the event of damp gases and vapor, condensate also
forms, causing an additional temperature reduction in relation to the process.
Cooling effect
The cooling effect depends on the pressure, medium and ambient temperature. Average cooling
effect for gases: 50 to 100 °C (122 to 212 °F)
26 Endress+Hauser
Mechanical accessories for pressure measuring devices
110 (4.33)
)
.2
(2
6
ø5
275 (10.8)
95 (3.74)
130 (5.12)
NPT ½"
27
G ½"
A0024011
Technical data
Maximum operating pressure • 104 bar (1 508 psi) at 400 °C (752 °F)
upstream from siphon (process side) • 120 bar (1 740 psi) at 300 °C (572 °F)
at maximum operating temperature 5) • 160 bar (2 320 psi) at 120 °C (248 °F)
1) Product Configurator, order code for "Pressure tapping", option "2" and order code for "Pipe; seal", option "1"
2) Cerabar M: Product Configurator, order code for "Accessories enclosed", option "P4".
3) Product Configurator, order code for "Pressure tapping", option "2" and order code for "Pipe; seal", option "2"
4) Additional process connections available
5) Pay attention to the pressure and temperature limits of the measuring device!
Endress+Hauser 27
Mechanical accessories for pressure measuring devices
27
ø20 (0.79)
NPT ½"
145 (5.71)
ø56 (2.2)
A0024012
Technical data
Maximum operating pressure • 104 bar (1 508 psi) at 400 °C (752 °F)
upstream from siphon (process side) • 120 bar (1 740 psi) at 300 °C (572 °F)
at maximum operating temperature 5) • 160 bar (2 320 psi) at 120 °C (248 °F)
1) Product Configurator, order code for "Pressure tapping", option "1" and order code for "Pipe; seal", option "1"
2) Cerabar M: Product Configurator, order code for "Accessories enclosed", option "P4".
3) Product Configurator, order code for "Pressure tapping", option "1" and order code for "Pipe; seal", option "2"
4) Additional process connections available
5) Pay attention to the pressure and temperature limits of the measuring device!
28 Endress+Hauser
Mechanical accessories for pressure measuring devices
~110 (4.33)
~110 (4.33)
G ½"
22 (0.87)
14 (0.55) 1 1
~40 (1.57)
~40 (1.57)
2 2
)
.5
.5
(3
(3
9
9
ø8
ø8
ø50 (1.97)
ø70 (2.76)
~95 (3.74)
~95 (3.74)
3 3
A0027980
Use For flow and level measurement applications in order to maintain constant conditions in the
condensate columns. Excess condensate can flow back into the main pipe or vessel.
Weight 1.7 kg (3.8 lb) 1.7 kg (3.8 lb) 2.2 kg (4.9 lb)
1) Product Configurator, order code for "Material; volume; PN", option "B"
2) Product Configurator, order code for "Material; volume; PN", option "C"
3) Product Configurator, order code for "Material; volume; PN", option "K"
4) Pay attention to the pressure and temperature limits of the measuring device!
5) Product Configurator, order code for "Additional options", option "F1"
Endress+Hauser 29
Mechanical accessories for pressure measuring devices
A0030607
Ordering information:
Product structure for DA63M, Product Configurator, order code for "Additional options", option "EC".
The mounting bracket set contains:
• 1 mounting bracket
• 1 U-bolt
• 2 Allen screws ISO4762 - M6x10
• 1 U-fixing bracket M8 for 2" pipe
• 2 washers 8.4 DIN 125-B
• 2 hexagonal nuts DIN EN 24032-M8
30 Endress+Hauser
Mechanical accessories for pressure measuring devices
Mounting bracket for 3- and If the transmitter is mounted on a shutoff device (e.g. manifold or shutoff valve), it is recommended
5-valve manifold to use the bracket provided. This makes it easier to disassemble the transmitter.
85 (3.35)
72 (2.83)
72 (2.83)
30 (1.18)
72 (2.83)
55 (2.17)
A0028158
Endress+Hauser 31
Mechanical accessories for pressure measuring devices
54 (2.13)
125 (4.92)
38 (1.5)
41.3 (1.63)
120 (4.72) 41.3 (1.63)
54 (2.13)
ø12 (0.47)
74 (2.91)
116 (4.57)
74 (2.91)
A0027981
Mounting kit • 7/16 UNF (Deltabar M and Deltabar S): A4-70 - • 71381907
• M12 (Deltabar S): A2-70 • On request
• M10 (Deltabar M and Deltabar S): A4-70 • On request
32 Endress+Hauser
Mechanical accessories for pressure measuring devices
Heavy-duty version Mounting bracket for wall and pipe mounting including retaining bracket for pipe mounting and two
nuts.
54 (2.13)
135 (5.31)
38 (1.5)
41.3 (1.63)
124 (4.88) 41.3 (1.63)
54 (2.13)
ø12 (0.47)
74 (2.91)
106 (4.17)
74 (2.91)
A0028156
Mounting kit • 7/16 UNF (Deltabar M and Deltabar S): A4-70 - • 7/16 UNF screws: 52024609
• M12 (Deltabar S): A2-70 • M12 screws: 52024610
• M10 (Deltabar M and Deltabar S): A4-70 • M10 screws: 52024611
Endress+Hauser 33
Mechanical accessories for pressure measuring devices
70 (2.76)
52 (2.05)
86 (3.39)
ø6 (0.24)
122 (4.8) 140 (5.51)
158 (6.22) 175 (6.89)
A0028493
Ordering information:
Product Configurator, order code for "Accessories enclosed", option "PA"
34 Endress+Hauser
Mechanical accessories for pressure measuring devices
~33 (1.3)
22
13
12
2
A0018749
• Observe the maximum pressure for compressed air hose and maximum overload for level probe
• Maximum pressure for the quick coupling piece provided: 10 bar (145 psi)
• Adapter material: 304 (1.4301)
• Material of quick coupling piece: anodized aluminum
• Order number 52011868
55
95 (3.74)
27 2
ø50 (1.97)
A0027982
• Observe the maximum pressure for compressed air hose and maximum overload for level probe
• Maximum pressure for the quick coupling piece provided: 10 bar (145 psi)
• Adapter material: 304 (1.4301)
• Material of quick coupling piece: anodized aluminum
• Order number 71110310
Endress+Hauser 35
Mechanical accessories for pressure measuring devices
36 Endress+Hauser
Mechanical accessories for pressure measuring devices
Additional accessories
Protective roofs Use
To protect the transmitter from direct sunshine, precipitation and ice.
135 (5.31)
123 (4.84)
95
(3
ø80 (3.15)
.7
70 (2.76)
4)
0,5 (0.02)
70 (2.76)
122 (4.8) 18 (0.71)
240 (9.45)
117 (4.61)
202 (7.95)
50 (1.97)
A0028009
Protective roof for Cerabar S, Deltabar S and Deltapilot S transmitters with T14 aluminum housing
and display.
Including bracket for direct installation on the transmitter housing.
Protective roofs are also available for Cerabar M with F31 and F15 housing.
Technical data
Material
Clamp screw A4
Retainer 316L
Endress+Hauser 37
Mechanical accessories for pressure measuring devices
124 (4.88)
105 (4.13)
4 (0.16)
34 (1.34)
A0028010
Protective roof for Cerabar S, Deltabar S and Deltapilot S transmitters with T14 aluminum housing
and display.
Technical data
Material
Welding flanges and weld-in For details refer to TI00426F/00/ "Weld-in adapters, process adapters and flanges".
adapters
38 Endress+Hauser
Mechanical accessories for pressure measuring devices
Flushing rings
Use flushing rings if there is a risk of medium buildup or clogging at the process connection. The
flushing ring is fitted between the process connection and the process connection provided by the
customer.
Using the two lateral flushing holes, medium buildup or clogging in front of the process isolating
diaphragm can be rinsed away and the pressure chamber vented.
Various nominal widths and forms allow adaption to the respective process flange.
Overview 1
6
5 2
3
5
4
A0034643
1 Flushing ring
2 Flushing hole
3 Locking screws 1/2 NPT (use suitable sealing material!)
4 Process connection provided by customer
5 Seals
6 Process connection of measuring device
Technical data
b
d1
d2
A0034648
1)
Material Nominal diameter Nominal pressure d1 d2 b Rinse connection 2) Weight
3)
EN1092-1 [mm] [mm] [mm] 2 x thread [kg (lb)]
ASME FNPT 1/2
DN25 PN16-400 30 68 30 0.72 kg (1.59 lb)
NPS 1" Class 150-2500 1.18 2.2 1.18 0.56 kg (1.23 lb)
NPS 2" Class 150-2500 2.44 3.62 1.18 1.00 kg (2.21 lb)
1) The specified nominal pressure applies to the flushing ring. The maximum pressure for the measuring device is dependent on the lowest-rated
element, with regard to pressure, of the selected components.
2) including 2 locking screws 316L
3) Use suitable sealing material!
Endress+Hauser 39
Mechanical accessories for pressure measuring devices
Order options Flushing rings can be ordered as a separate accessory or as an order option for the device.
1)
Material Nominal diameter Approval Accessory 2) Order option 3) 4)
Part number
Cerabar Deltabar
EN1092-1
DN25 - 71377379 PO PO - -
DN50 - 71377380 PP PP PP PP
DN80 - 71377383 PQ PQ PQ PQ
AISI 316L
ASME B16.5
40 Endress+Hauser
Mechanical accessories for pressure measuring devices
Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field ->
Open product page -> The "Configure" button to the right of the product image opens the Product
Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop
Supplementary documentation
Field of Activities Pressure measurement, powerful instruments for process pressure, differential pressure, level and
flow:
FA00004P/00/
Field of Activities System components and data manager solutions to complete your measuring point:
FA00016K/09/
Endress+Hauser 41
*71381283*
71381283