Professional Documents
Culture Documents
Tank Inspection (DRAFT) Rev.2
Tank Inspection (DRAFT) Rev.2
15 x
x
16 x 1
x
2
x x
13
x x 3
14 4
12
x x6
11x
x5
x x
10 8
x9 x G
7
Foundation 10 mm 10 mm
DEFORMING TANK
Location Gap, G
EP-P-110-1 EP-P-110-2 EP-R-110-1 EP-R-110-2 EP-S-110-1 EP-S-110-2
1 0.30 0.00 1.45 0.00 0.40 0.00
2 0.25 0.20 1.70 0.70 0.80 0.00
S45
3 0.50 1.30 0.07 0.80 1.30 4.80
4 0.50 1.50 0.50 1.20 2.40 5.50
5 2.20 1.30 0.00 5.40 0.00 3.15
6 1.90 1.25 0.50 5.30 0.00 2.80
S135
7 0.80 0.03 0.65 4.50 6.50 2.80
8 0.85 0.04 1.30 4.20 6.10 2.80
9 0.00 2.20 0.55 0.04 4.30 0.20
10 0.00 2.40 0.80 0.00 4.10 0.00
S225
11 2.40 1.70 0.25 5.50 8.10 4.00
12 2.50 1.30 0.30 5.40 7.90 3.80
13 0.00 0.00 0.45 0.00 0.00 1.19
14 0.70 0.45 1.25 0.60 0.00 2.80
S315
15 3.20 0.60 0.80 4.20 3.00 0.35
16 3.70 1.50 1.40 5.10 3.35 2.00
Notes:
1. All dimension are in milimeters (mm).
2. Measurements taken are 10 mm (approximately) from the inner and outer edge on both side of all 4 saddles.