Professional Documents
Culture Documents
Plant Communication System Catalogue4 PDF
Plant Communication System Catalogue4 PDF
(1) Communication (2) Communication (3) Integration of Plant (4) PA-GA functions,
between control room between different field communication system for automatic
operators and field operators with EPABX System broadcasting of
operators. stored voice
messages / alarm
tones during
emergency
System Channels
1. Page Channel:
2. Party Channel:
System Configuration
– Junction Boxes
– Cables for field equipment
Plant Communication System TeleNet
Plant Communication System TeleNet
Gooseneck microphone
Individual zone selection switches for
14 zones OR for 06 zones
All zone selection
Siren access
Press to talk switch
The announcement made by the control room operator will be heard only in
that selected Zone / Zones. On hearing the announcement (message) over the
field loudspeakers of the system, the called person goes to any of his nearest
Field Handset Station and directly contacts the control room, simply, by dialing
the MCS number.
The incoming call on to the MCS is by way of: Pleasant ringing tone, Flashing
LED indication and calling field station’s number & area name display over the
digital display of the MCS.
The distance between MCS and the location of Central rack can be up to
700 meters.
Cables for MCS: 1 X 6 core, 1 x 25 core and 1 x 2 pair (Note: Cables up
to 30-meter length would be part of MCS).
More than one MCS can also be installed in the same system.
The announcement made from the MCS has highest priority over the
announcements made from field (field handset stations) or made from EPABX
intercoms.
Plant Communication System TeleNet
It is pure IP (VOIP - SIP) based, Communication Server system, with Hybrid capability to
TDM enable digital and analog stations. The central exchange is expandable up to 320
ports. It can support Analog Terminals, Digital Terminals and VOIP terminals. It can
support Analog Trunk, Digital Trunk and VOIP trunk. It is State of the art, futuristic
technology and it has tremendous scope of advancement, as it is IP Based.
It is a rack mounted cabinet that house the back plane (i.e. Mother board) and
contain card slots for the system power supply, Main Processor Board, digital
interface board, analog station interface board, paging interface board, Trunk
interface board, IP boards and many other essential boards.
The CPC is in 19” sub rack construction and is designed for free floor standing.
It houses the hardware: Preamplifier module, power amplifier modules, control
circuit panel, CSS unit, main distribution frame, others.
The system is designed for zone wise announcements, which is more effective
in locating a person in the field rather than individual loudspeaker paging. The
zoning is flexible and can be designed at site to meet the geographical layout.
The field hand set stations are to be installed at multiple locations in the
outdoor field and are suitable for wall/structure mounting. The field stations
are available in variety of constructions to meet indoor / outdoor environment.
1) Flameproof Ex’d’, intrinsic safe (Ex ib), IP66 protected, field station, wall
mountable type, in Aluminum Alloy LM6, for hazardous area, Zone 1 & 2,
gas group IIB / IIA, Temp. T6.
2) Weatherproof, IP 66, Field Station, wall mountable type, in Aluminum
Alloy, for safe (non – hazardous) areas.
3) Indoor desktop analog station(for non-noisy, non-dusty, non humid area)
4) Indoor desktop, digital station (for non-noisy, non-dusty, non humid area)
5) VOIP / SIP based weatherproof, IP66, field station with DISPLAY
All outdoor field stations has dynamic / Noise canceling microphone (for
effective communication from noise areas), magnetically operated HOOK
SWITCH operation, ABS handset with cord protected in SS metallic tubing, 16
Keys push button keypad and external canopy in Fibre for extra protection.
The loudspeakers are with built in line matching transformer and have local
tapings to vary the loudspeaker output.
(a) Junction box for field handset stations (FSJB): These are wall mountable
type JB and are used in the system for distributing the cables meant for
field handset stations.
For hazardous areas, the JB is certified for Gas Group IIB/ IIA, Zone 1 &
Zone 2. It is weatherproof IP66 protected and its material of construction is
LM6 (Aluminum alloy).
(b) Junction box for loudspeakers (LSJB): These are wall mountable type JB
and are used in the system for termination of loudspeaker cables.
The junction boxes are of 4-way type. There shall be 01 opening on each
side of the JB, of size ¾ inch ET. The JB is provided with Clip-On type
connector for cable termination.
Cables
The different cables, which required for the system, are:
(a) Loudspeaker cable: 0.75 sq. mm, 2 cores, ATC, PVC insulated, Twin
twisted, PVC inner sheathed, over all armored loudspeaker cable.
[Instead of 0.75 sq.mm , we can also use 1.0 sq. mm. OR 1.5 sq. mm]
(c) Telephone cable: 0.5 mm (diameter), 2 pair, ATC, PVC insulated, Twin
twisted, PVC inner sheathed, over all armored telephone cable.
System Features
Centralized, modular amplifier based system
Page channel for announcement purpose
Party channels for talk back / private communication purpose
Direct Communication between field operators and control room operator
Field to Field Contact: Direct (without any assistance from control room
operator)
Connectivity / integration of PA system with the EPABX - Telephone System
Individual zone wise, multiple zone wise and ALL ZONE announcement
facility from master control station of the CONTROL ROOM.
Individual zone wise / Individual Group wise and All zone
ANNOUNCEMENT facility from field handset stations
Monitoring the healthiness of the associated equipment of the PA System
An attention / alert sound over the loudspeakers prior to actual
announcement
Facility of connecting emergency siren over the paging channel (Highest
Priority)
Digital display at MCS for identification of field handset numbers & it’s area
location
Call holding facility at MCS
Provision to connect multiple Master Control Station in the same system
No requirement of AC Power supply, in the field for any of field equipment
Functional Features provided to each field station can be restricted by
software programming
Highest priority for the announcement made from the control room from
MCS
Individual status LED indication on the MCS for each field handset stations
The system is 100Volt line matching type to facilitate the use of
loudspeakers at longer distance.
No correlation on number of field handset stations and the number of
loudspeakers, to be deployed in PA system
The quantity, location and their functioning shall be 100% independent
Networking of PA Systems
Integration of PA system with Mobile Phone
Integration of PA system with F&G system
Plant Communication System TeleNet
Additional Features
The plant EPABX System / Telephone system can be integrated with the
paging system. With this integration it will be possible to have 2 way
communication between field handset stations of the PA system and
telephones / intercoms of EPABX / Telephone system. Also telephone user can
make paging announcement (message broadcasting) on PA system.
Networking of PA system
The system has the facility to broadcast Pre recorded voice messages OR
Pre recorded alarm tone over the PA system loudspeakers.
Message / Alarm Tone Generator Unit is provided for this purpose. Up to 08
voice messages / alarm tones can be stored in the system. These messages /
tones are then selected by the users as per their requirement. The selection of
desired message / tone (for broadcasting) is either done manually or it can be
done automatically. In case of automatic selection, the potential free contacts
from DCS system Or Fire alarm system or Gas detection system etc. are used.
Salient Features
Maintenance
In the system, location and quantity of both field stations and loudspeakers
are not inter linked. There can be more number of loudspeakers in the system
then the number of field stations.
Plant Communication System TeleNet
Reduced cabling
The system needs simple and economical field cabling. The field stations are
wired with 2 pair telephone cable in star fashion. This reduces the length of
the cable and in turns the cost. Further the system does not require any power
source and hence the expensive power cabling. The loudspeakers are
connected in looped fashion using 2 core loudspeaker cables.
It’s a modular architecture based system. System can be built block by block
to meet the present requirement and with enough provision for future
expansion. There is no limitation or restriction to the number of handset
stations and number of loudspeakers to be deployed in the system. The plant
communication system can be configured and designed to meet all types of
needs.
Application:
It is suitable for use in any industrial plant or any
such environment or commercial complex along
with the PA system for the following purpose:
Relaying of safety / security / fire alarm
messages
Broadcasting of evacuation instruction /
advices
Broadcasting of any Public Utility General
Message
KEY FEATURES:
Design based on micro controller technology The messages have priorities amongst
Mounting: 19” Rack mountable, in 2 U height themselves, with ‘Message #1’ having the
(where 1U = 44.5 mm) highest priority. Thus the sequence for
Color: Black broadcasting of the messages can be
Input supply voltage: 230 V AC, 50 Hz configured (set) by the users at site during
LCD panel available in the front for identifying installation, as per the requirement
the particular Message No #. that is being The triggering (selection) of the desired
played / broadcasted message are done automatically (remotely)
Each Unit has 08 message storage capacity, through potential free contacts. In such case,
which are stored in a built-in Memory Card of the potential free contacts from DCS system
4 GB (where 1 GB = 10 Hrs. approximately) Or Fire alarm system or Gas detection
Multiple unit is multiplexed to have 8 / 16 / 24 system etc. are used to trigger the message.
/ 32 /40 message capacity The triggering / selection of desired
Messages are stored in the module in .MP3 messages can also be done manually by the
file format users, from an external / separate MESSAGE
The user provides their desired messages in ACCESS CONSOLE (Optional Item). The
.MP3 file format. The messages are then user has to select the corresponding switch
transferred in the Memory Card of the unit, for broadcasting the desired message.
through USB port.
The messages can be broadcasted over all
the loudspeakers of the PA system in ALL
ZONE mode (over all the loudspeakers) OR it
can be broadcasted in a particular ZONE
AREA (over few loudspeakers only)
Other Benefits: Easy To Install, Easy to Operate and Very User Friendly