FRU or FIELD vi Stenoscop / Stenoscop plus| INSTRUCTIONS model 6000/9000 CCD FRU Number FRU Description 8289556615 CABLE ASSEMBLY CONTROL MONITOR 1. Tools required 1.1. Standard Tool Kit 2. Preliminery Precautions 2.1, Switch OFF the unit. 2.2. Wait till the Inverter light goes OFF. 2.3. Remove the connector (9PL1) from the monitor cart. 3. Procedure of replacing the Cable Assembly 3.1. Procedure to remove the old cable from the Buggy. 3.1.1. Open the Rear Cover of the buggy. 3.4.2, Disconnect the BNC Connecter. 3.1.3. Disconnect the Shielding wires. 3.1.4. Disconnact wires 17, 18, 19, 23 from Inverter. 3.1.5. Distonnect wires 20, 21, 22. 8.1.8. Cpen the Cable Gland Nut 3.4.7. Open/out the Tie Wraps. 3.1.8. Remove Ferrite coil 3.1.9. Pull out the Shielding Cable. ‘Made by: Amol Tile : FIELD INSTRUCTION FOR CABLE ASSEMBLY CONTROL MONITOR. | Checked by : Prabir Mazumdar Doe, No. : €209556615 INS Approved by : Prabir Mazumdar Page 2 of 5 Revno. 000 Dt 18 December, 1999 Base: Revision History Sheet (Nol Supplied) "Distribution = Manafctaring, Fld 3.2.2, Mount the P Clip to the Monitor Cable Assembly 3.2.1. Fix the Cable with Flexible Cable Gland, and Giand Nut so as to maintain the above shown distance 165mm (Important), CAUTION : ENSURE THAT STATIC GROUNDING SHIELD SHOULD BE TOUCHING TO GROUND. 3.2.3. Connect Monitor cable no, 36 ‘3.2.4. Monitor Cable connection to meee Inverter assembly. Made by : Amol Title : FEELD INSTRUCTION FOR CABLE ASSEMBLY CONTROL, MONITOR Checked by : Prabir Mazumdar Doc. No. : 8289556615 INS Approved by : Prabir Mazumdar Page 3 of 5 Rev no. 000 Dt 18 December, 1999 age 1 Revision History Shest (Not Supplied) Distribution Manufteturing, Fd FRU For Stenoscop / Stemoscop plus INSTRUGHON S model 6000/9000 CCD 3.2.6. Fixing of Ferrite Core. \ (410. of turns to be wound on sowroncasGeemminen —owmoR ARLE wr nes Shout boner Heaps 3.28. Connect 3PLS and 3PL, 3.2.8. Thermal sleeve fixing on BNC joint. 3.2.7. C-Arm Cable and Monitor cable BNC joint. Made by : Amol ” Title : FIRLD INSTRUCTION FOR CABLE ASSEMBLY CONTROL, MONITOR Checked by : Prabir Mazumdar Dee, Ne. : 8229556615 INS Approved by : Prabir Mazumdar Page 4 of 5 Rev no. 000 DE 18 December, 1999 ‘Page I: Revision History Sheet (Not Supplied) ‘Distribution : Manufacturing, Field (The no. of Tie fot be more or toss than 12) 3.2.9. Cable Tie Wrapping, Wraps should $2.10. After finishing all the connection assemble the buggy rear cover. Made by : Amol Title : FIELD INSTRUCTION FOR CABLE ASSEMBLY CONTROL MONITOR Checked by : Prabir Mazumdar Doe. No. : 8289556615 INS Approved by: Prabir Mazumdar Page 5 of 5 Revo. 000° Dt 18 December, 1959 [Rage |: Revision History Sheet (Not Supplied) ‘Distribution: Manufacturing, Fda KIT 828955G615_ ‘| MONITOR CART-UNIT CABLE ‘The monitor cart -unit cable for Stenoscop 2-D6/D9-6000/9000 including tae CCD version is the same as the monitor cart unit-cable used in the Stenoscop LE, excepted the position af the jumper Pl in 9PL1 plug, This one is inserted between outlets 32/43 for the Stenoscop 2 series. For Stenoscop LE, move the jumper from 33 to 3 (see schematic hare uncler) r MODULE 9 ~ INTERFACE : au ED wm Only for 100, ‘oy 120 als Note: for the first Stenoscop 2 series( Serial Nb. from 10900 to 10908 included itis necessary to remove the key ottof 9PL1 plug or to replace the cart plug by anew one including the key, reference 8297330015.

You might also like